6
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049 www.canam-construction.com 1 PRODUCT DATASHEET Roof Deck Type H6 Long Span Deck Type H6 Technical Data Depth 6” Rib width 9” Fy 40 ksi Cover width 12” Product Options available: Cellular Acoustic Cellular/acoustic Finishes available: Galvanized ASTM A653, G60, G90 and A25 Galvanized plus weldable primer Shop applied finish paints are available Gage Section properties* Wt (psf) Ip (in 4 ) In (in 4 ) Sp (in 3 ) Sn (in 3 ) 18 4.3 6.69 7.41 1.97 2.05 16 5.5 8.76 9.43 2.61 2.67 * Ip, In, Sp and Sn are the section properties per foot of width. Gage Single Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection 16'-0'' 17'-0'' 18'-0'' 19'-0'' 20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0'' 18 124 / 107 117 / 89 111 / 75 105 / 64 100 / 55 95 / 47 91 / 41 16 200 / 140 188 / 117 178 / 98 168 / 84 154 / 72 140 / 62 127 / 54 117 / 47 107 / 41 Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity. 9” 6” 12” Cover

THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT

For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049

www.canam-construction.com

1PRODUCT DATASHEETRoof Deck Type H6

Long Span Deck Type H6Technical Data

Depth 6”

Rib width 9”

Fy 40 ksi

Cover width 12”

Product

Options available:CellularAcousticCellular/acoustic

Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available

GageSection properties*

Wt (psf)

Ip (in4)

In (in4)

Sp (in3)

Sn (in3)

18 4.3 6.69 7.41 1.97 2.05

16 5.5 8.76 9.43 2.61 2.67

* Ip, In, Sp and Sn are the section properties per foot of width.

GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection

16'-0'' 17'-0'' 18'-0'' 19'-0'' 20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0''

18 124 / 107 117 / 89 111 / 75 105 / 64 100 / 55 95 / 47 91 / 41

16 200 / 140 188 / 117 178 / 98 168 / 84 154 / 72 140 / 62 127 / 54 117 / 47 107 / 41

Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.

9”

6”

12” Cover

Page 2: THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT

For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049

www.canam-construction.com

2PRODUCT DATASHEETRoof Deck Type H7.5

Long Span Deck Type H7.5Technical Data

Depth 71⁄2”

Rib width 9”

Fy 40 ksi

Cover width 12”

Product

Options available:CellularAcousticCellular/acoustic

Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available

GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection

20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0'' 25'-0'' 26'-0'' 27'-0'' 28'-0''

18 90 / 92 86 / 79 82 / 69 78 / 60 75 / 53

16 153 / 120 146 / 104 140 / 90 133 / 79 128 / 70 123 / 62 118 / 55 113 / 49 105 / 44

Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.

GageSection properties*

Wt (psf)

Ip (in4)

In (in4)

Sp (in3)

Sn (in3)

18 4.80 11.21 12.11 2.65 2.64

16 6.10 14.70 15.56 3.54 3.47

* Ip, In, Sp and Sn are the section properties per foot of width.

9”

7½”

12” Cover

Page 3: THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT

For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049

www.canam-construction.com

3PRODUCT DATASHEETRoof Deck Type J4.5

Long Span Deck Type J4.5Technical Data

Depth 41⁄2”

Rib width 9”

Fy 40 ksi

Cover width 12”

Product

Options available:CellularAcousticCellular/acoustic

Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available

GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection

11'-0'' 12'-0'' 13'-0'' 14'-0'' 15'-0'' 16'-0'' 17'-0'' 18'-0'' 19'-0''

20 99 / 112 91 / 86 84 / 68 78/ 54

19 141 / 137 130 / 106 120 / 83 111 / 67 104 / 54 97 / 45

18 187 / 163 172 / 125 159 / 99 147 / 79 133 / 64 117 / 53 104 / 44

16 299 / 217 268 / 167 229 / 132 198 / 105 172 / 86 152 / 71 135 / 59 120 / 50 108 / 42

Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.

GageSection properties*

Wt (psf)

Ip (in4)

In (in4)

Sp (in3)

Sn (in3)

20 2.8 2.28 2.73 0.88 0.97

19 3.3 2.79 3.20 1.10 1.17

18 3.8 3.31 3.63 1.27 1.35

16 4.8 4.42 4.57 1.64 1.71

* Ip, In, Sp and Sn are the section properties per foot of width.

9”

4½”

12” Cover

Page 4: THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT

For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049

www.canam-construction.com

4PRODUCT DATASHEETRoof Deck Type LS4.5

Long Span Deck Type LS4.5Technical Data

Depth 41⁄2”

Rib width 81⁄8”

Fy 40 ksi

Cover width 12”

Product

Options available:CellularCellular/acoustic

Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available

GageSection properties*

Wt (psf)

Ip (in4)

In (in4)

Sp (in3)

Sn (in3)

16 4.90 4.84 4.86 1.94 2.00

14 6.10 6.06 6.06 2.46 2.49

12 8.60 8.45 8.45 3.44 3.44

10 11.00 10.82 10.82 4.38 4.38

* Ip, In, Sp and Sn are the section properties per foot of width.

GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection

17'-0'' 18'-0'' 19'-0'' 20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0'' 25'-0''

16 159 / 64 142 / 54 127 / 46

14 202 / 81 180 / 68 162 / 58 146 / 50 133 / 43

12 282 / 113 252 / 95 226 / 81 204 / 69 185 / 60 169 / 52 155 / 45 142 / 40

10 359 / 144 320 / 121 288 / 103 260 / 88 236 / 76 215 / 66 197 / 58 181 / 51 167 / 45

Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.

81/8”

12” Cover

4½”

Page 5: THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

Long Span Deck Type LS6Technical Data

Depth 6”

Rib width 81⁄8”

Fy 40 ksi

Cover width 12”

Product

THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT

For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049

www.canam-construction.com

5PRODUCT DATASHEETRoof Deck Type LS6

Options available:CellularCellular/acoustic

Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available

GageSection properties*

Wt (psf)

Ip (in4)

In (in4)

Sp (in3)

Sn (in3)

16 5.50 9.45 9.52 2.85 3.00

14 6.90 11.87 11.87 3.70 3.74

12 9.60 16.55 16.55 5.18 5.18

10 12.40 21.19 21.19 6.60 6.60

* Ip, In, Sp and Sn are the section properties per foot of width.

GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection

23'-0'' 24'-0'' 25'-0'' 26'-0'' 27'-0'' 28'-0'' 29'-0'' 30'-0'' 31'-0''

16 127 / 51 117 / 45

14 166 / 64 152 / 56 140 / 50 130 / 44

12 233 / 89 214 / 78 197 / 69 182 / 62 169 / 55 157 / 49 147 / 44 137 / 40

10 296 / 114 272 / 100 251 / 89 232 / 79 216 / 70 201 / 63 187 / 57 175 / 51 164 / 47

Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.

81/8”

6”

12” Cover

Page 6: THE ROOF DECK YOU NEED FOR YOUR NEXT …...Long Span Deck Type LS6 Technical Data Depth 6” Rib width 81⁄ 8” Fy 40 ksi Cover width 12” Product THE ROOF DECK YOU NEED FOR YOUR

THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT

For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049

www.canam-construction.com

6PRODUCT DATASHEETRoof Deck Type LS7.5

Long Span Deck Type LS7.5Technical Data

Depth 71⁄2”

Rib width 81⁄8”

Fy 40 ksi

Cover width 12”

Product

Options available:CellularCellular/acoustic

Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available

GageSection properties*

Wt (psf)

Ip (in4)

In (in4)

Sp (in3)

Sn (in3)

16 6.10 15.94 16.08 3.85 4.11

14 7.70 20.04 20.04 5.07 5.11

12 10.70 27.94 27.94 7.10 7.10

10 13.80 35.77 35.77 9.04 9.04

* Ip, In, Sp and Sn are the section properties per foot of width.

GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection

26'-0'' 27'-0'' 28'-0'' 29'-0'' 30'-0'' 31'-0'' 32'-0'' 33'-0'' 34'-0''

16 116 / 59 111 / 53 107 / 48 104 / 43

14 177 / 75 164 / 67 153 / 60 142 / 54 133 / 49 125 / 44 117 / 40

12 249 / 104 231 / 93 215 / 83 201 / 75 188 / 68 176 / 61 165 / 56 155 / 51 146 / 47

10 318 / 133 295 / 119 274 / 107 256 / 96 239 / 87 224 / 79 210 / 71 198 / 65 186 / 60

Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.

81/8”

7½”

12” Cover

Notes :

CyanC

MagentaM

JauneY

NoirK

PMS PMS PMS PMS PMS PMS PMS

DieD

épreuveinterne

Approbation directeur création :

Coordonnatrice

Révision

Conseillère

N˚ dossier

Épaisseur

Format Bleed

Format final

impression

Approbation révision : Date :

Approbation interne : Approbation client : Date :

Le « trapping » de ce document n’a pas été vérifié a été vérifié

épreuveclient

Le « Codes-barres » du document position seulement sont bons

L’imposition de ce document n’a pas été vérifié a été vérifié

Signer cette épreuve SVP

Client

Description

Nom document

Format doc.

Logiciel

Infographiste

Designer - D.A

Dir. création

Polices

Type de papier

Type de reliure

Type impression

Date

506 McGill, 5e étage,Montréal (Québec), H2Y 2H6

tél. : 866.5521 / 1 866 966.5521 téléc. : 866.3272 / 1 888 896.3272