7/23/2019 Thermo Oil Heater http://slidepdf.com/reader/full/thermo-oil-heater 1/1 HTT energy systems GmbH - Postfach 1922, 32009 Herford/Germany - Füllenbruchstr. 183, 32051 Herford/Germany Tel. 05221/385-0 - Fax 05221/385-12 - Internet: www.htt.de - e-mail: [email protected] Sitz Herford, Handelsregister Bad Oeynhausen, HRB 5413, Geschäftsführer: Harald Peterson, Dr. Dietmar Hunold energy systems Inquiry data sheet Thermal oil heater, fired (wtö) G:\DAT_HTT\TK\DATENBLA\ANFRAGEN\wto_en.doc / Stand: 05/2004 Your project / consumer [-] HTT no. [-] Net heating capacity / inflow temperature [kW] / [°C] Volume flow /  T heater  *1) [m³/h] / [K] Heat transfer medium [-] Permissible min. / max. operating temperature heater (TS) [°C] Max. permissible operating overpressure heater (PS) [bar] Construction requirement   Pressure equipment directive    [-] Design   horizontal   vertical Installation   Inside installation   Outside installation Installation above NSL [m] Fuel   Light oil EL viscosity [mm²/s] at [°C] Heavy fuel oil S viscosity [mm²/s] at [°C] Natural gas H u  _____________  [kWh/Nm³] / [kWh/kg] Inlet pressure [mbar] Other fuel (analysis necessary) H u  _____________  [kWh/Nm³] / [kWh/kg] Power voltage 400 / 500 / V / 50 / 60 Hz Control voltage V / 50 / 60 Hz  Air preheater   Yes   No Content of heat transfer fluid (customer’s side) [l] Remarks *1) Should not be lower than 20 - 25 K because of the effect on the pressure loss and consequently on the power demand of the circulating pump!

Thermo Oil Heater

Embed Size (px)

Citation preview

Page 1: Thermo Oil Heater

7/23/2019 Thermo Oil Heater

http://slidepdf.com/reader/full/thermo-oil-heater 1/1

HTT energy systems GmbH - Postfach 1922, 32009 Herford/Germany - Füllenbruchstr. 183, 32051 Herford/GermanyTel. 05221/385-0 - Fax 05221/385-12 - Internet: www.htt.de - e-mail: [email protected]

Sitz Herford, Handelsregister Bad Oeynhausen, HRB 5413, Geschäftsführer: Harald Peterson, Dr. Dietmar Hunold

energy systems

Inquiry data sheet

Thermal oil heater, fired (wtö)G:\DAT_HTT\TK\DATENBLA\ANFRAGEN\wto_en.doc / Stand: 05/2004

Your project / consumer [-]

HTT no. [-]

Net heating capacity / inflow temperature [kW] / [°C]

Volume flow /  T heater   *1)

[m³/h] / [K]

Heat transfer medium [-]

Permissible min. / max. operating temperature heater (TS) [°C]

Max. permissible operating overpressure heater (PS) [bar]

Construction requirement   Pressure equipment directive     [-]

Design   horizontal   vertical

Installation   Inside installation   Outside installation

Installation above NSL [m]

Fuel   Light oil EL viscosity [mm²/s] at [°C]

Heavy fuel oil S viscosity [mm²/s] at [°C]

Natural gas Hu _____________    [kWh/Nm³] / [kWh/kg]

Inlet pressure [mbar]

Other fuel (analysis necessary)

Hu _____________    [kWh/Nm³] / [kWh/kg]

Power voltage 400 / 500 / V / 50 / 60 Hz

Control voltage V / 50 / 60 Hz

 Air preheater    Yes   No

Content of heat transfer fluid (customer’s side) [l]

Remarks

*1)Should not be lower than 20 - 25 K because of the effect on the pressure loss and consequently on thepower demand of the circulating pump!