This document was prepared in conjunction with work accomplished under Contract No.DE-AC09-96SR18500 with the U. S. Department of Energy.

DISCLAIMER

This report was prepared as an account of work sponsored by an agency of the United StatesGovernment. Neither the United States Government nor any agency thereof, nor any of theiremployees, makes any warranty, express or implied, or assumes any legal liability or responsibilityfor the accuracy, completeness, or usefulness of any information, apparatus, product or processdisclosed, or represents that its use would not infringe privately owned rights. Reference herein toany specific commercial product, process or service by trade name, trademark, manufacturer, orotherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring bythe United States Government or any agency thereof. The views and opinions of authors expressedherein do not necessarily state or reflect those of the United States Government or any agencythereof.

This report has been reproduced directly from the best available copy.

Available for sale to the public, in paper, from: U.S. Department of Commerce, National TechnicalInformation Service, 5285 Port Royal Road, Springfield, VA 22161,phone: (800) 553-6847,fax: (703) 605-6900email: [email protected] ordering: http://www.ntis.gov/help/index.asp

Available electronically at http://www.osti.gov/bridgeAvailable for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S.Department of Energy, Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN37831-0062,phone: (865)576-8401,fax: (865)576-5728email: [email protected]

Page 3: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No
Page 4: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WSRC-TR-2003-00137

iv

CONTENTS

LIST OF FIGURES ........................................................................................................................V LIST OF TABLES ........................................................................................................................ VI EXECUTIVE SUMMARY ............................................................................................................ 1 1 INTRODUCTION.................................................................................................................... 2 2 VERSE-LC CST ION-EXCHANGE-COLUMN MODEL.................................................... 3

2.1 Assumptions ................................................................................................................... 3 2.2 Governing Equations ...................................................................................................... 3 2.3 Axial Dispersion............................................................................................................. 4 2.4 Film Diffusion................................................................................................................ 4 2.5 Molecular Diffusion And Pore Diffusion....................................................................... 5 2.6 Equilibrium Cesium Isotherm........................................................................................ 5 2.7 Numerical Method.......................................................................................................... 6

3 CNEA TEST CASES ............................................................................................................... 8 3.1 Column Tests.................................................................................................................. 9 3.2 Plant Column System................................................................................................... 10

4 PRELIMINARY EVALUATION OF THE TWO-COLUMN SYSTEM ............................. 12 5 NOMENCLATURE............................................................................................................... 15 6 REFERENCES....................................................................................................................... 16

Page 5: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WSRC-TR-2003-00137

v

LIST OF FIGURES Fig. 1. CNEA Equilibrium Loading Data at 25oC ......................................................................... 6 Fig. 2. Orthogonal Collocation on Finite Elements – Computational Grid ................................... 7 Fig. 3. Relative Exit Cesium Concentration for the Column Tests ............................................. 10 Fig. 4. Relative Exit Cesium Concentration for the Plant Column System................................. 11 Fig. 5. Mass Transfer Zone Length Determination...................................................................... 12 Fig. 6. Two-Column System........................................................................................................ 13 Fig. 7. Column-Length Sizing Curve for the Two-Column System............................................ 14

Page 6: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WSRC-TR-2003-00137

vi

LIST OF TABLES Table 1. CNEA Waste Feeds ......................................................................................................... 8 Table 2. VERSE-LC Column Model Parameter Settings .............................................................. 9

Page 7: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 1 of 16 _____________________________________________________________________________________________________________________

EXECUTIVE SUMMARY The U.S. Department of Energy (DOE) and the Nuclear Energy Commission of Argentina (CNEA) have a collaborative project to separate cesium/strontium from waste resulting from the production of Mo-99. The Pacific Northwest National Laboratory (PNNL) is assisting DOE on this joint project by providing technical guidance to CNEA scientis ts. As part of the collaboration, PNNL staff works with staff at the Savannah River Technology Center (SRTC) to run the VERSE-LC model for removal of cesium from the Mo-99 waste using the crystalline silicotitanate (CST) material (IONSIV IE-911, UOP LLC, DesPlaines, IL) based on technical data provided by CNEA. This report discusses the VERSE-LC ion-exchange-column model and the predicted results for CNEA test cases. The major accomplishments of this study include: • A “best estimate” value of 0.22 is used for (Dp/D∞) in this report based on a previous study

that determined (Dp/D∞) by utilizing the breakthrough data for several representative column performance tests conducted at SRS, Hanford and Oak Ridge National Laboratory (ORNL). For future use, it is recommended that (Dp/D∞) be fitted to the breakthrough data of CNEA waste.

• The breakthrough curves for the column tests are established at three different waste flow

rates (i.e., 17.8 cm3/hr, 59.3 cm3 /hr, and 148 cm3/hr). The results show a faster breakthrough with increasing flow rates. These breakthrough curves provide data for comparison with the test data and with the output from the CNEA model.

• For the plant column system, the VERSE-LC model predicts that the exit cesium

concentration reaches the limit imposed by the required decontamination factor of 1040 after ~353.5 hours of operation and 62.57 liters of waste (i.e., 78.2% of the specified 80- liter batch) passed through the system.

• In a preliminary evaluation of the two-column system, a column-length sizing curve is

obtained for a column diameter of 1.38 cm. The sizing curve can be expanded for a range of column lengths in the future.

Page 8: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 2 of 16 _____________________________________________________________________________________________________________________

1 INTRODUCTION The CNEA is investigating the selective removal of cesium and strontium from the Mo-99 production waste stream. Through the Joint Coordinating Committee for Radioactive and Mixed Waste Management between CNEA and DOE, a collaborative proposal was made to study cesium and strontium separations from the Mo-99 waste (Collaboration Agreement, 2001). Argentine researchers have been conducting experiments to evaluate the performance of an ion exchange column using IONSIV IE-911 (the engineered form of CST manufactured by UOP LLC, DesPlaines, IL) for cesium removal. The ion exchange technology using CST to remove cesium from radioactive waste has been studied at major DOE sites (Savannah River Site, Hanford), and computer models to calculate CST ion exchange column size and performance were developed at the Savannah River Technology Center (SRTC) using a PC-based version of VERSE-LC software (Walker, 1998; Hamm et al., 2001). VERSE-LC (VErsatile Reaction SEparation simulator for Liquid Chromatography), developed by Professor N.-H. Linda Wang (School of Engineering, Purdue University) to model liquid adsorption, ion exchange and liquid chromatography processes (Whitley and Wang, 1998), has been licensed to SRTC to assist in the column test predictions for both the SRS and Hanford programs. VERSE-LC had been thoroughly verified by SRTC researchers (Hamm et al., 1999). PNNL is assisting DOE on this joint project by providing technical guidance to CNEA scientists. As part of the collaboration, PNNL staff works with SRTC staff to run the VERSE-LC model for removal of cesium from the Mo-99 wastes based on detailed description of the Mo-99 waste stream provided by CNEA. This report discusses the VERSE-LC ion-exchange-column model, the predicted results of CNEA test cases, and a preliminary evaluation of the two-column system.

Page 9: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 3 of 16 _____________________________________________________________________________________________________________________

2 VERSE-LC CST ION-EXCHANGE-COLUMN MODEL 2.1 Assumptions The VERSE-LC model for CST ion exchange column describes the loading of cesium onto the granular CST ion-exchanger fixed bed. The mathematical method applicable to mass transfer in a porous medium is utilized to account for bulk convection, axial dispersion, film mass transfer, pore diffusion, and adsorption. The method involves the following basic assumptions: 1. The solution contains only two components, i.e., a solvent and a single solute (cesium). 2. Plug flow with constant volumetric flow rate through the packed column. 3. No radial concentration gradients in the column. 4. Isothermal process within the column. 5. Solid particles are spherical, uniform in size, and do not swell or shrink. 6. Negligible surface diffusion with Fickian pore diffusion dominating. 7. No angular concentration gradients within a particle. 8. Constant pore diffusivity. 9. Local equilibrium between the solute concentration adsorbed on the solid and the local solute

concentration in the solution. 2.2 Governing Equations A porous particle-diffusion model proposed for simulation of fixed-bed adsorption processes (Berninger et al., 1991) was adopted for the VERSE-LC CST ion-exchange-column model. The porous particle-diffusion model provides the material balance equations in both the mobile phase and the pore phase. An “effective” binary solute-solvent system is assumed. Furthermore, for ionic species modeling, the total ionic strength of the feed solution is assumed to be equal to the native solution within the column. Mobile phase:

)()1(3

,2

2

pRrpbp

bfob CC

R

k

zC

uz

CE

tC

=−−

−∂∂

−∂

∂=

∂∂

ε

ε (1)

z = 0: ))0,(( oob CtCuzC

E −=∂∂

(2)

z = L: 0=∂∂

zC

(3)

t = 0: ),0( zCC = (4)

Page 10: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 4 of 16 _____________________________________________________________________________________________________________________

Pore phase:

∂∂

=∂

∂∂

−+r

Cr

rr

D

t

C

CQ pp

pp

ppp

22

)1( εεε (5)

r = 0: 0=∂

r

C p (6)

r = Rp : )( , pRrpfp

pp CCkr

CD =−=

∂ε (7)

t = 0: ),0( rCC pp = (8)

2.3 Axial Dispersion Axial dispersion in packed columns is the result of mechanical dispersion added onto molecular diffusion. For practical flowrates, mechanical dispersion dominates. In the low Reynolds number range of interest, axial dispersion coefficient, Eb, is estimated by the Chung and Wen correlation (Chung and Wen, 1968):

)Re011.02.0(2

48.0+=pbb

oR

LE

Luε

(9)

The Reynolds number, Re, in Equation 9 is defined as:

µ

ερ bop uR2Re = (10)

2.4 Film Diffusion For both the laboratory-scale test column and the plant column proposed by CNEA, with the IONSIV IE-911 CST particle-size distributions, the Reynolds number is much less than 1. VERSE-LC applies the Wilson and Geankoplis (1966) correlation to determine the film mass transfer coefficient, kf, in this low Reynolds number range:

3/23/2 Re09.1 −=

bbo

f Scu

k

εε (11)

With the Schmidt number, Sc, defined as:

Page 11: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 5 of 16 _____________________________________________________________________________________________________________________

=

∞DSc

ρµ

(12)

2.5 Molecular Diffusion And Pore Diffusion CST-packed columns are mass-transfer limited, giving rise to relatively slow “kinetics.” Therefore, in predicting cesium-breakthrough behavior for CST packed columns, the pore diffusion coefficient should be an important parameter. The “effective” cesium pore diffusion coefficient Dp can be normalized with respect to the free stream “Brownian” diffusion coefficient D∞. The inverse of this ratio is referred to as a tortuosity factor that is primarily dependent upon the internal structure of the porous material. For materials with very large pores, a tortuosity factor approaching unity is observed, while for very small pores, factors approaching zero can result. The rate of “kinetics” is inversely related to the tortuosity factor. The “best estimate” value of this ratio (Dp/D∞) was determined by utilizing the breakthrough data for several representative column performance tests conducted at SRS, Hanford and ORNL. From these test data, the “best estimate” value of 0.22 is obtained for the ratio (Dp/D∞). The molecular (or Brownian) diffusion coefficient D∞ is estimated by the Nernst-Haskell equation and then corrected for temperature and viscosity. A detailed discussion of Dp and D∞ is given elsewhere (Hamm et al., 2001). Although other researchers (Anthony, 2001) suggested a much lower value (i.e., 0.06) for (Dp/D∞), the value of 0.22 is used in this report. For future use, it is recommended that (Dp/D∞) be fitted to the breakthrough data of CNEA waste. 2.6 Equilibrium Cesium Isotherm Solid-phase concentrations Q are related to pore-phase concentrations Cp by isotherms. The non-linear Langmuir isotherm is selected to represent the Q-Cp relationship:

p

ppb

bC

Ca

Q+

−−=

1)1)(1( εε

(13)

Langmuir coefficients a and b are obtained by fitting Eq. (13) to CNEA equilibrium loading data at 25oC. The Langmuir isotherm and equilibrium data are shown in Fig. 1.

Page 12: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 6 of 16 _____________________________________________________________________________________________________________________

C (mg Cs/mL)

0.000 0.005 0.010 0.015

Q (

mg

Cs/

mL

CS

T)

0

20

40

60

80

100

120

140

160

Equilibrium data (Run E5)Langmuir Isotherma = 7145 ml/ml BVb = 48.3343 ml/mg CsEquilibrium data (Run E6)

Cs+ in WasteFeed

Fig. 1. CNEA Equilibrium Loading Data at 25oC

2.7 Numerical Method The method of orthogonal collocation on finite elements is applied to numerically solve Eqs. (1) and (8). The method provides a mathematical technique in which a series of orthogonal polynomials are used as trial functions, the collocation points are taken as the roots to one of those polynomials, and the dependent va riables are the solution values at the collocation points. The entire domain is divided into a set of elements. Orthogonal polynomials defined for each element are pieced together to provide an approximation over the whole domain (Finlayson, 1980). Fig. 2 below illustrates the grid arrangement in the orthogonal collocation method.

Page 13: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 7 of 16 _____________________________________________________________________________________________________________________

Mobile Phase

Por

e P

hase

z = 0 z = L

r = Rp

r = 0

Element boundariesInterior axialcollocationpoints

Inte

rior

por

eco

lloca

tion

poin

ts

Fig. 2. Orthogonal Collocation on Finite Elements – Computational Grid (Example shown: 3 interior collocation points per axial element,

4 interior collocation points in the particle element)

Page 14: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 8 of 16 _____________________________________________________________________________________________________________________

3 CNEA TEST CASES CNEA provided data for four test cases to be predicted by the VERSE-LC column model. The first three cases are for the column tests conducted at three different waste feed flow rates. The fourth case is for the plant column test. The four test cases are summarized below: • Test Case 1: Column test with the waste feed flow rate 17.8 cm3 /hr. • Test Case 2: Column test with the waste feed flow rate 59.3 cm3 /hr. • Test Case 3: Column test with the waste feed flow rate 148 cm3 /hr. • Test Case 4: Plant column with the waste feed flow rate 177 cm3/hr. Data on waste feeds for the test cases are given in Table 1 that includes waste composition, viscosity and density. All data were provided by CNEA.

Table 1. CNEA Waste Feeds

Column Tests

(Test Cases 1, 2 and 3) Plant Column (Test Case 4)

Concentration (M) Na+ Cs+ Sr+ OH- AlO2

- Cl-

3.50

0.000024

2.76 0.74

3.50

0.000024 0.000003

2.76 0.74 0.004

Viscosity at 20oC (cP) 2.6 2.6 Density at 20oC (g/ml) 1.15 1.15 The parameters employed in the VERSE-LC column model are shown in Table 2. For all test cases, six interior collocation points per axial element and four interior collocation points in the particle element are specified. This discretization scheme seems adequate for the CNEA test cases. The number of axial elements can be varied to achieve the desired accuracy. The effects of theses parameters (i.e. number of axial elements, number of interior axial collocation points, and number of interior particle collocation points) on the convergence of the system and the computational speed have been studied elsewhere (Berninger et al., 1991).

Page 15: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 9 of 16 _____________________________________________________________________________________________________________________

Table 2. VERSE-LC Column Model Parameter Settings

Parameters Test Case 1 Test Case 2 Test Case 3 Test Case 4

Column length L 11.8 cm 11.8 cm 11.8 cm 39.6 cm Column diameter 0.8 cm 0.8 cm 0.8 cm 1.38 cm Particle radius Rp 245.25 µm 245.25µm 245.25 µm 245.25 µm Bed porosity εb 0.48 0.48 0.48 0.48 Particle porosity εp 0.23 0.23 0.23 0.23 Feed flow rate 0.29667 ml/min

(17.8 cm3/hr) 0.98834 ml/min (59.3 cm3/hr)

2.4667 ml/min (148 cm3/hr)

2.95 ml/min (177 cm3/hr)

Feed viscosity µ 0.026 P 0.026 P 0.026 P 0.026 P Feed density 1.15 g/ml 1.15 g/ml 1.15 g/ml 1.15 g/ml Feed cesium concentration

0.00319 mg/ml (0.000024 M)

0.00319 mg/ml (0.000024 M)

0.00319 mg/ml (0.000024 M)

0.00319 mg/ml (0.000024 M)

Brownian diffusivity D∞

6.34702E-4 cm2/min

6.34702E-4 cm2/min

6.34702E-4 cm2/min

6.34516E-4 cm2/min

Pore diffusivity Dp 1.39634E-4 cm2/min

1.39634E-4 cm2/min

1.39634E-4 cm2/min

1.39594E-04 cm2/min

Langmuir coefficient a

7145 mg/ml 7145 mg/ml 7145 mg/ml 7145 mg/ml

Langmuir coefficient b

48.3343 ml/mg 48.3343 ml/mg 48.3343 ml/mg 48.3343 ml/mg

Number of axial elements

25

25

25

100

Number of interior axial collocation points

6

6

6

6

Number of interior particle collocation points

4

4

4

4

3.1 Column Tests Test cases 1, 2 and 3 deal with the laboratory-scale column tests. The objective for the VERSE-LC column model is to predict the breakthrough curves at specified conditions. These predicted breakthrough curves provide data for comparison with the experimental data and with the output data from the CNEA model. Using parameter settings given in Table 2, three VERSE-LC model runs were made to simulate the three column tests. Fig. 3 displays the predicted relative cesium concentrations at the column outlet vs. time (i.e., breakthrough curves). The results show that the breakthrough is faster with increasing waste feed flow rates.

Page 16: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 10 of 16 _____________________________________________________________________________________________________________________

Time (hrs)

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

C/C

o at

Col

umn

Out

let

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

17.8 cm3/hr59.3 cm3/hr148 cm3/hr

Waste feed flow rate

Fig. 3. Relative Exit Cesium Concentration for the Column Tests (Co: Cesium concentration in the waste feed)

3.2 Plant Column System Test case 4 corresponds to the plant column system in which the Mo-99 waste is fed to the ion exchange plant column at 177 cm3/hr. The required decontamination factor DF for the plant column system is 1040. If DF is defined as the ratio of (Co/Cf) with Co and Cf being the feed and exit cesium concentrations, respectively, then Cf cannot exceed 2.3077x10-8 M, provided that Co is 0.000024 M. Based on CNEA specifications of this test case as listed in Tables 1 and 2, a VERSE-LC run was performed. Fig. 4 shows the calculated result. The VERSE-LC model predicts that the exit cesium concentration reaches the limit after ~353.5 hours of operation and 62.57 liters of waste (i.e., 78.2% of the specified 80- liter batch) passed through the system.

Page 17: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 11 of 16 _____________________________________________________________________________________________________________________

Time (hrs)

0 50 100 150 200 250 300 350 400 450 500

C/C

o at

Col

umn

Out

let

0.000

0.001

0.002

0.003

0.004

353.5 hours

Exit cesium concentration limit

1/1040

Fig. 4. Relative Exit Cesium Concentration for the Plant Column System (Co: Cesium concentration in the waste feed)

Page 18: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 12 of 16 _____________________________________________________________________________________________________________________

4 PRELIMINARY EVALUATION OF THE TWO-COLUMN SYSTEM CNEA has expressed interest in evaluation of a two-column system. The sizes would be chosen in order to hold approximately 90% of the cesium in the first column. This column would be used in the manufacture of cesium sources. The second column, intended to load the remaining 10% of cesium, would be considered solid waste. Professor Wang at Purdue University proposed the mass transfer zone (MTZ) approach for sizing a system of ion-exchange columns. The MTZ length is a function of isotherm parameters, cesium feed concentrations, mass transfer parameters, and linear velocity. If the isotherm is nonlinear at the concentration level in the waste solution of interest, the concentration waves eventually develop into a constant pattern (Walker, 1998). For demonstration, assuming that (1) the column diameter is specified (e.g., 4ft or 1.2192m), (2) a breakthrough of 90% is desired in the first column, and (3) the exit cesium concentration limit in the second column is 1.3x10-6 mg/ml (a concentration limit used at SRS), the MTZ is defined as the length of column required to contain the cesium concentration wave from 90% of the feed concentration to 1.3x10-3 mg/l. In the simulation to determine the MTZ length, a single column is chosen sufficiently long so that the concentration waves can reach a constant pattern. The MTZ length determination is illustrated in Fig. 5 that plots cesium concentration as a function of relative column position (normalized by the simulation column length Lc). If the constant pattern MTZ length, LMTZ, is selected to be the column length, the two-column system will have a total length of 2 LMTZ.

Column Position, z/Lc

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Cs

Co

nce

ntr

atio

n (

mg

/ml)

1e-7

1e-6

1e-5

1e-4

1e-3

1e-2

1e-10.9 Co

1.3E-6 mg/ml

LMTZ: Mass transfer zone length Fig. 5. Mass Transfer Zone Length Determination

(Column Diameter: 4ft or 121.92cm)

Page 19: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 13 of 16 _____________________________________________________________________________________________________________________

Unfortunately, the MTZ approach to sizing ion-exchange columns is not applicable here since the CNEA isotherm displays a high degree of linearity at the cesium concentration level in the Mo-99 waste feed as shown in Fig. 1. In this case, no constant pattern of the concentration waves develops and the MTZ length keeps increasing. Hence, a constant pattern LMTZ cannot be determined. This preliminary evaluation study assumes that all specifications (with the exception of the column length) and conditions for the plant column also apply to the two-column system. Again, a decontamination factor DF of 1040 is required, resulting in an exit cesium concentration limit of 2.3077x10-8 M (or 3.067x10-6 mg/ml), provided that Co is 0.000024 M. A series of VERSE-LC runs were made for the selected column diameter of 1.38 cm. In each run, a column length was specified and the run was terminated when the exit cesium concentration in column 2 exceeds the specified limit. Fig. 6 shows the VERSE-LC result for the 80-cm column length. The cesium concentration limit at the column 2 exit is reached at ~3870 hours. The breakthrough in the first column is ~43.5%.

Time (hours)

0 500 1000 1500 2000 2500 3000 3500 4000

C/C

o at

Co

lum

n 1

Exi

t

0.0

0.2

0.4

0.6

0.8

1.0

Co

lum

n 2

Exi

t C

s C

on

cen

trat

ion

(m

g/m

L)

0.0

5.0e-7

1.0e-6

1.5e-6

2.0e-6

2.5e-6

3.0e-6

3.5e-6

Fig. 6. Two -Column System

(Column Diameter: 1.38 cm; Column Length: 80 cm) The result of all VERSE-LC runs for the two-column system is shown in Fig. 7 that displays the column length as a function of cesium breakthrough in the first column. If desired, this column-length sizing curve can be obtained for a range of column diameters.

Page 20: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 14 of 16 _____________________________________________________________________________________________________________________

Column 1 Breakthrough C/Co

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Co

lum

n L

eng

th (c

m)

0

20

40

60

80

100

120

140

160

180

200

Fig. 7. Column-Length Sizing Curve for the Two-Column System (Column Diameter: 1.38 cm)

Page 21: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 15 of 16 _____________________________________________________________________________________________________________________

5 NOMENCLATURE a Langmuir coefficient, mg/ml B.V. (B.V.: Volume of the fixed bed) b Langmuir coefficient, ml/mg C Bulk-phase cesium concentration, mg/ml Cp Pore-phase cesium concentration, mg/ml Co Column inlet cesium concentration, mg/ml Dp Pore diffusivity, cm2/min D∞ Brownian diffusivity, cm2/min Eb Axial dispersion coefficient, cm2/min kf Film mass transfer coefficient, cm/min L Column length, cm LMTZ Mass transfer zone length Q Solid-phase solute concentration, mg/ml S.V. (S.V.: Volume of the solid phase) r Radial position from center of adsorbent particle, cm Re Reynolds number Rp Adsorbent particle radius, cm Sc Schmidt number t Time, min uo Linear interstitial velocity, cm/min z Position in axial direction, cm εb Bed porosity εp Intraparticle porosity µ Viscosity, g s-1 cm-1

ρ Density, g/ml

Page 22: This document was prepared in conjunction with work .../67531/metadc740491/m2/1/high_res... · This document was prepared in conjunction with work accomplished under Contract No

WESTINGHOUSE SAVANNAH RIVER COMPANY REPORT: WSRC-TR-2003-00137 Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV IE-911) Date: June 2003 Column for Cesium Removal from Argentine Waste (U) Page: 16 of 16 _____________________________________________________________________________________________________________________

6 REFERENCES Anthony, R.G., 2001. “Crystalline Silicotitanate Ion Exchange Support for Salt Alternatives,” Final Report for KF-90594-O, August 15, 2001. Berninger, J.A., R.D. Whitley, X. Zhang, and N.-H L. Wang, 1991. “A Versatile Model for Simulation of Reaction and Nonequilibrium Dynamics in Multicomponent Fixed-Bed Adsorption Processes,” Comp. Chem. Eng., 15 (11), 749-768. Chung, S.F. and C.Y. Wen, 1968. “Longitudinal Dispersion of Liquid Flowing through Fixed and Fluidized Beds,” AIChE J., 14, 857-866. Collaboration Agreement (Contract) between the United States Department of Energy and the National Atomic Energy Commission Argentina. September, 2001. Finlayson, B.A., 1980. “Nonlinear Analysis in Chemical Engineering,” McGraw-Hill, New York. Hamm, L.L., T. Hang, D.J. McCabe and W.D. King, 2001. “Preliminary Ion Exchange Modeling for Removal of Cesium from Hanford Waste Using Hydrous Crystalline Silicotitanate Material,” WSRC-TR-2001-00400. Hamm, L.L., F.G. Smith III, and M.A. Shadday, 1999. “QA Verification Package for VERSE-LC Version 7.80 (U),” WSRC-TR-99-00238. Walker, D. D., 1998. “Modeling of Crystalline Silicotitanate Ion Exchange Columns using Experimental Data from Simulated SRS Waste,” WSRC-TR-98-00396. Whitley, R.D. and N.-H.L. Wang, 1998. “User’s Manual - VERSE (Versatile Reaction Separation) Simulation for Liquid Phase Adsorption and Chromatography Processes,” Purdue University, School of Chemical Engineering, November, 1998. Wilson, E.J. and C.J. Geankoplis, 1966. “Liquid Mass Transfer at Very Low Reynolds Numbers in Packed Beds,” Ind. Eng. Chem. Fund., 5, 9-14.