Energy Efficient. Performance Guaranteed.• Scalable for any size tank, any flow rate, and any removal percentage. • No major infrastructure changes required.• Install without taking the tank or clearwell out of service.• Only 30 inches of head space required for standard equipment.• Specialized low head space versions are available requiring only 24 inches.• Portable. Can be moved and reinstalled to adapt to system demand.• Designed for long life, clog-free operation and minimal maintenance.• Only one 24-inch or larger tank hatch or opening required for installation.
• Factory placement is available.
THM & VOC Removal SolutionsIn-Tank Spray Aeration SystemsIn-Tank Spray Aeration Systems
53
1
4
2
SN Series In-Tank Spray Aeration SystemSN Series In-Tank Spray Aeration System
Headspace Ventilation: Ground-Mounted and On-TankHeadspace Ventilation: Ground-Mounted and On-Tank
Main System Components1. SN Series Spray Aeration System with 3DX Nozzle Technology.
2. Floor-Resting Intake Structure and Intake Hose.
3. Pendulum Guide System keeps SN equipment in place.
4. Headspace Ventilation. Can be tank-mounted or ducted from the ground when high CFM is required.
5. Tank Mixing. Can be added to the system when needed.
1826_20210520
Brochure
©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | [email protected]
AIRIN
H2OIN
SYST
EM P
RESS
URE
TO
FIR
ST C
HA
MBE
R
AIROUT
Distribution Main Line
THM RemovalSpray Aeration
Chamber
AIRIN
LOW
PRE
SSU
RE T
O N
EXT
CHA
MBE
R AIROUT
H2OOUT
RE-PRESSURIZE
SystemPressure+1 PSI
THM RemovalSpray Aeration
Chamber
DISTRIBUTION MAIN LINE
H2OOUT
RE-PRESSURIZE
H2OIN
DISTRIBUTION MAIN LINE
AIROUTAIR
IN
THM RemovalSpray Aeration
Chamber SystemPressure+1 PSI
SYST
EM P
RESS
URE
TO
CH
AM
BER
AIRIN
AIROUT
Distribution Main Line
THM RemovalSpray Aeration
Chamber
AIRIN
RE-PRESSURIZE
AIROUT
H2OIN
H2OOUT
SystemPressure+1 PSI
SYST
EM P
RESS
URE
TO
ALL
CH
AM
BERS
THM RemovalSpray Aeration
Chamber
RE-PRESSURIZERE-PRESSURIZE
SystemPressure+1 PSI
DISTRIBUTION MAIN LINE
Single Chamber System
Multi Chamber System- In Series
Multi Chamber System- In Parallel
In-Line Spray Aeration Stations allow a City to remove THMs in a specific neighborhood or remote end-of-line region. This may be the best solution when the distribution flow can bypass a tank and go directly to the user. The City’s engineer can design the pad, piping retrofit and building to fit the desired project parameters.
• Can be customized for virtually any gallons per minute, gallons per day or THM removal requirement.
• Easy to service by city personnel.
• Designed to never impede flow in either direction through the mainline pipe. (Very important for fire protection or in the event of a power outage)
• No checkvalves that can malfunction and affect flow through the mainline.
Completely scalable to fit your needs!
In-Line THM Removal Station BuildingIn-Line THM Removal Station Building
Please contact us to discussTHM removal solutions!