VICINITY MAP SCALE: N.T.S. 1. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF/HERSELF WITH THE SCOPE OF WORK AND ALL CONDITIONS AFFECTING THE NEW PROJECT. 2. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS OF THE JOB SITE AND CONFIRM THAT WORK AS INDICATED ON THESE CONSTRUCTION DOCUMENTS CAN BE ACCOMPLISHED AS SHOWN PRIOR TO COMMENCEMENT OF ANY WORK. 3. ALL FIELD MODIFICATIONS BEFORE, DURING, OR AFTER CONSTRUCTION SHALL BE APPROVED IN WRITING BY A VERIZON REPRESENTATIVE. 4. INSTALL ALL EQUIPMENT AND MATERIALS PER THE MANUFACTURER'S RECOMMENDATIONS, U.N.O. 5. NOTIFY VERIZON, IN WRITING, OF ANY MAJOR DISCREPANCIES REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND DESIGN INTENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATIONS FROM A VERIZON REPRESENTATIVE AND ADJUSTING THE BID ACCORDINGLY. 6. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK UNDER THE CONTRACT. 7. CONTRACTOR SHALL PROTECT ALL EXISTING IMPROVEMENTS AND FINISHES THAT ARE TO REMAIN. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY OCCUR DURING THE CONSTRUCTION TO THE SATISFACTION OF A VERIZON REPRESENTATIVE. 8. THE CONTRACTOR IS RESPONSIBLE FOR RED-LINING THE CONSTRUCTION PLANS TO ILLUSTRATE THE AS BUILT CONDITION OF THE SITE. FOLLOWING THE FINAL INSPECTION BY VERIZON, THE CONTRACTOR SHALL PROVIDE VERIZON WITH ONE COPY OF ALL RED-LINED DRAWINGS. 9. VERIFY ALL FINAL EQUIPMENT WITH A VERIZON REPRESENTATIVE. ALL EQUIPMENT LAYOUT, SPECS, PERFORMANCE INSTALLATION AND THEIR FINAL LOCATION ARE TO BE APPROVED BY VERIZON. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS/HER WORK WITH THE WORK AND CLEARANCES REQUIRED BY OTHERS RELATED TO SAID INSTALLATIONS. PROPERTY OWNER: PEOPLE'S UNITED METHODIST CHURCH 5110 TAMLIN ROAD COLORADO SPRINGS, CO 80915 CONTACT: DARNELL ALLEN PHONE: 719-596-0368 JURISDICTION: PIKES PEAK REGIONAL BUILDING DEPARTMENT 2880 INTERNATIONAL CIRCLE, SUITE 200-7 COLORADO SPRINGS, COLORADO 80910 BUILDING DEPARTMENT PHONE: 719-385-5982 JURISDICTION: 5321001007 RADIATION FROM THIS FACILITY WILL NOT INTERFERE WITH OPERATION OF OTHER COMMUNICATION DEVICES. A PORTION OF THE W1/2 OR THE SW1/4 OF THE NW1/4 OF SECTION 21, T13S, R65W OF THE SIXTH PRINCIPAL MERIDIAN, COUNTY OF EL PASO, STATE OF COLORADO. LATITUDE: 38°54'23.77"N LONGITUDE: 104°40'50.36"W FROM THE VERIZON OFFICE LOCATED AT 3131 SOUTH VAUGH WAY, AURORA, COLORADO:HEAD WEST ON S VAUGHN WAY. TURN LEFT ONTO THE I-225/S PARKER RD RAMP. MERGE ONTO CO-83 N/S PARKER RD. USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE LEFT 2 LANES TO TAKE EXIT 1A FOR I-25 S TOWARD COLO SPRINGS. KEEP LEFT AND MERGE ONTO I-25 S. TAKE EXIT 153 FOR INTERQUEST PKWY. CONTINUE ONTO INTERQUEST PKWY. TURN RIGHT ONTO CO-21 S. KEEP LEFT TO STAY ON CO-21 S. USE THE LEFT 2 LANES TO TURN LEFT ONTO STETSON HILLS BLVD. TURN RIGHT ONTO MARKSHEFFEL RD. TURN LEFT ONTO TAMLIN RD. TURN LEFT AT ACCESS ROAD. DESTINATION WILL BE ON THE LEFT. 3131 SOUTH VAUGHN WAY, SUITE 550 AURORA, COLORADO 80018 APPROVED FOR CONSTRUCTION PROJECT NAME: BY DESCRIPTION REV SAVE DATE: SHEET TITLE: DATE SHEET NUMBER: CHK PROJECT ADDRESS: DESIGNED FOR: DESIGNED BY: BKT 0 03/03/20 - 5110 TAMLIN ROAD EL PASO COUNTY 3/3/2020 2:47 PM CSP TAMLIN T1 EXISTING LEASE RRH/BBU ANTENNAS FIBER DC HYBRID CABLES/ NEW WORK/ WALL EXISTING EASEMENT AREA POWER COAX EASEMENT HATCH TITLE SHEET T1 TITLE SHEET 0 C1 SITE PLAN 0 C2 ELEVATIONS 0 C3 SHELTER MAPPING 0 NORTH SP1 SPECIFICATION & PHOTO SHEET 0 SITE CSP TAMLIN PUBLIC RECORD PARCEL NO. 5321001007 5110 TAMLIN ROAD COLORADO SPRINGS, CO 80938 EL PASO COUNTY EXISTING COMMUNICATIONS SITE 850 INSTALLATION PROJECT RF1 ANTENNA INFORMATION 0 RF2 ANTENNA CUT SHEET(S) 0 C4 0 J5 INFRASTRUCTURE PARTNERS 8392 S CONTINENTAL DIVIDE RD UNIT 101 LITTLETON, CO 80127 CONTACT: AARON ZAJICEK PHONE: 303-683-3194 EXT. 154 REV. SHEET TITLE VERIZON CONSTRUCTION DEPARTMENT 3131 SOUTH VAUGHN WAY, SUITE 550 AURORA, COLORADO 80014 CONTACT: MIKE HICKEY PHONE: 951-413-9704 KAPPA CONSULTING 1917 LOWELL BLVD. DENVER, CO 80204 CONTACT: KELLY HARRISON PHONE: 303-748-0599 EMAIL: [email protected] ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING APPLICABLE CODES: USED Code Year / Type: (ORDINANCE) X 2017 PIKES PEAK REGIONAL BUILDING CODE (RBC) X 2015 INTERNATIONAL BUILDING CODE (IBC) X 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) X 2015 INTERNATIONAL MECHANICAL CODE (IMC) X 2015 INTERNATIONAL PLUMBING CODE (W/O CHAP. 13) (IPC) X 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) X 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) X 2017 NATIONAL ELECTRICAL CODE (NEC) REFER TO BUILDING PERMIT DOCUMENTS AND ALL CONSTRUCTION DOCUMENTS FOR ADDITIONAL CODE REQUIREMENTS. THIS PROJECT CONSISTS OF THE FOLLOWING: SIX (6) EXISTING PANEL ANTENNAS SIX (6) EXISTING RRH UNITS SIX (6) NEW PANEL ANTENNAS SIX (6) NEW RRH UNITS ONE (1) NEW COMMSCOPE POWERSHIFT 21 24 Three (3) RRH's removed from equipment shelter on north side of building and replaced in stealth tower. Three (3) RRH's removed and replaced within stealth tower. Six (6) antennae removed and replaced within stealth tower. No change to existing equipment count noted. Project File COM-20-011 By:Ryan Howser Date:03/06/2020 El Paso County Planning & Community Development Approved

Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

VICINITY MAPSCALE: N.T.S.

1. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL FAMILIARIZEHIMSELF/HERSELF WITH THE SCOPE OF WORK AND ALLCONDITIONS AFFECTING THE NEW PROJECT.

2. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS ANDDIMENSIONS OF THE JOB SITE AND CONFIRM THAT WORK ASINDICATED ON THESE CONSTRUCTION DOCUMENTS CAN BEACCOMPLISHED AS SHOWN PRIOR TO COMMENCEMENT OF ANYWORK.

3. ALL FIELD MODIFICATIONS BEFORE, DURING, OR AFTERCONSTRUCTION SHALL BE APPROVED IN WRITING BY A VERIZONREPRESENTATIVE.

4. INSTALL ALL EQUIPMENT AND MATERIALS PER THEMANUFACTURER'S RECOMMENDATIONS, U.N.O.

5. NOTIFY VERIZON, IN WRITING, OF ANY MAJOR DISCREPANCIESREGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS,AND DESIGN INTENT. THE CONTRACTOR SHALL BE RESPONSIBLEFOR OBTAINING CLARIFICATIONS FROM A VERIZONREPRESENTATIVE AND ADJUSTING THE BID ACCORDINGLY.

6. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALLCONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES,AND PROCEDURES OF THE WORK UNDER THE CONTRACT.

7. CONTRACTOR SHALL PROTECT ALL EXISTING IMPROVEMENTS ANDFINISHES THAT ARE TO REMAIN. CONTRACTOR SHALL REPAIR ANYDAMAGE THAT MAY OCCUR DURING THE CONSTRUCTION TO THESATISFACTION OF A VERIZON REPRESENTATIVE.

8. THE CONTRACTOR IS RESPONSIBLE FOR RED-LINING THECONSTRUCTION PLANS TO ILLUSTRATE THE AS BUILT CONDITIONOF THE SITE. FOLLOWING THE FINAL INSPECTION BY VERIZON, THECONTRACTOR SHALL PROVIDE VERIZON WITH ONE COPY OF ALLRED-LINED DRAWINGS.

9. VERIFY ALL FINAL EQUIPMENT WITH A VERIZON REPRESENTATIVE.ALL EQUIPMENT LAYOUT, SPECS, PERFORMANCE INSTALLATIONAND THEIR FINAL LOCATION ARE TO BE APPROVED BY VERIZON.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATINGHIS/HER WORK WITH THE WORK AND CLEARANCES REQUIRED BYOTHERS RELATED TO SAID INSTALLATIONS.

PROPERTY OWNER: PEOPLE'S UNITED METHODIST CHURCH5110 TAMLIN ROADCOLORADO SPRINGS, CO 80915

CONTACT: DARNELL ALLEN PHONE: 719-596-0368JURISDICTION: PIKES PEAK REGIONAL BUILDING DEPARTMENT

2880 INTERNATIONAL CIRCLE, SUITE 200-7COLORADO SPRINGS, COLORADO 80910

BUILDING DEPARTMENTPHONE: 719-385-5982

JURISDICTION: 5321001007

RADIATION FROM THIS FACILITY WILL NOT INTERFERE WITHOPERATION OF OTHER COMMUNICATION DEVICES.

A PORTION OF THE W1/2 OR THE SW1/4 OFTHE NW1/4 OF SECTION 21, T13S, R65W OFTHE SIXTH PRINCIPAL MERIDIAN, COUNTYOF EL PASO, STATE OF COLORADO.

LATITUDE: 38°54'23.77"N

LONGITUDE: 104°40'50.36"W

FROM THE VERIZON OFFICE LOCATED AT 3131 SOUTH VAUGHWAY, AURORA, COLORADO:HEAD WEST ON S VAUGHN WAY. TURNLEFT ONTO THE I-225/S PARKER RD RAMP. MERGE ONTO CO-83N/S PARKER RD. USE THE RIGHT 3 LANES TO TAKE THEINTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE LEFT 2LANES TO TAKE EXIT 1A FOR I-25 S TOWARD COLO SPRINGS.KEEP LEFT AND MERGE ONTO I-25 S. TAKE EXIT 153 FORINTERQUEST PKWY. CONTINUE ONTO INTERQUEST PKWY. TURNRIGHT ONTO CO-21 S. KEEP LEFT TO STAY ON CO-21 S. USE THELEFT 2 LANES TO TURN LEFT ONTO STETSON HILLS BLVD. TURNRIGHT ONTO MARKSHEFFEL RD. TURN LEFT ONTO TAMLIN RD.TURN LEFT AT ACCESS ROAD. DESTINATION WILL BE ON THELEFT.

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

T1

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

TITLE SHEET

T1 TITLE SHEET 0

C1 SITE PLAN 0C2 ELEVATIONS 0C3 SHELTER MAPPING 0

NORTH

SP1 SPECIFICATION & PHOTO SHEET 0

SITE

CSP TAMLINPUBLIC RECORD PARCEL NO. 5321001007

5110 TAMLIN ROADCOLORADO SPRINGS, CO 80938

EL PASO COUNTY

EXISTING COMMUNICATIONS SITE850 INSTALLATION PROJECT

RF1 ANTENNA INFORMATION 0RF2 ANTENNA CUT SHEET(S) 0

C4 0J5 INFRASTRUCTURE PARTNERS8392 S CONTINENTAL DIVIDE RD UNIT 101LITTLETON, CO 80127

CONTACT: AARON ZAJICEKPHONE: 303-683-3194 EXT. 154

REV.SHEET TITLEVERIZONCONSTRUCTION DEPARTMENT3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80014

CONTACT: MIKE HICKEYPHONE: 951-413-9704

KAPPA CONSULTING1917 LOWELL BLVD.DENVER, CO 80204

CONTACT: KELLY HARRISONPHONE: 303-748-0599EMAIL: [email protected]

ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING APPLICABLE CODES:

USED Code Year / Type: (ORDINANCE)

X 2017 PIKES PEAK REGIONAL BUILDING CODE (RBC)

X 2015 INTERNATIONAL BUILDING CODE (IBC)

X 2015 INTERNATIONAL RESIDENTIAL CODE (IRC)

X 2015 INTERNATIONAL MECHANICAL CODE (IMC)

X 2015 INTERNATIONAL PLUMBING CODE (W/O CHAP. 13) (IPC)

X 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

X 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC)

X 2017 NATIONAL ELECTRICAL CODE (NEC)

REFER TO BUILDING PERMIT DOCUMENTS AND ALL CONSTRUCTION DOCUMENTS FORADDITIONAL CODE REQUIREMENTS.

THIS PROJECT CONSISTS OF THE FOLLOWING: ▪ SIX (6) EXISTING PANEL ANTENNAS ▪ SIX (6) EXISTING RRH UNITS ▪ SIX (6) NEW PANEL ANTENNAS ▪ SIX (6) NEW RRH UNITS ▪ ONE (1) NEW COMMSCOPE POWERSHIFT

21

24

Three (3) RRH's removed from equipment shelter onnorth side of building and replaced in stealth tower.

Three (3) RRH's removed and replaced within stealthtower.

Six (6) antennae removed and replaced within stealthtower.

No change to existing equipment count noted.

Project File COM-20-011

By:Ryan HowserDate:03/06/2020El Paso County Planning & Community Development

Approved

Page 2: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

SP1

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

SPECIFICATION & PHOTOSHEET

CENTERLINE

PENNY

ROUND/DIAMETER℄

d

Ø

APPROXIMATELY~

SPOT ELEVATION

CONTROL OR DATUM POINT

EQUIPMENT ORFIXTURE NUMBER

KEYED NOTE

T.C. 1631.33F.L. 1631.00

TOP OF WALL

1639.00

NEW CONTOUR

EXISTING CONTOUR

PROPERTY LINE

SHEET WHERE TAKENSHEET WHERE DRAWN

SECTION LETTER

SHEET WHERE TAKEN

SHEET WHERE DRAWN

REFERENCE LETTEROR NUMBER

SHEET WHERE TAKENSHEET WHERE DRAWN

DETAIL NUMBER 1631

1631

SECTION OR DETAILSCALE:

1. CONTRACTOR IS RESPONSIBLE FOR ERECTING TEMPORARY BARRICADES AND/OR FENCING TOPROTECT THE SAFETY OF THE PUBLIC DURING CONSTRUCTION. THE CONTRACTOR SHALLREMOVE ALL TEMPORARY BARRIERS AND REPAIR ALL DAMAGE TO PROPERTY ON THE SITECAUSED BY THIS CONSTRUCTION. THE COST OF REPAIR IS THE CONTRACTOR'S RESPONSIBILITY.

2. ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND FEDERALREQUIREMENTS.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL MEASUREMENTS AT THESITE PRIOR TO ORDERING ANY MATERIALS OR CONDUCTING ANY WORK.

4. EXCESS SOIL MATERIAL AND DEBRIS CAUSED BY THIS CONSTRUCTION SHALL BE REMOVEDFROM THE SITE AND DISPOSED OF IN A LEGAL MANNER.

5. CONTRACTOR SHALL MAKE ADJUSTMENTS TO GRADING ELEVATIONS AS NECESSARY TOENSURE A SITE FREE OF DRAINAGE PROBLEMS.

6. CONTRACTOR SHALL COORDINATE A CONSTRUCTION LAYDOWN AREA WITH THE PROPERTYOWNER. CONSTRUCTION LAYDOWN AREA SHALL BE FENCED-IN WITH TEMPORARY (45 DAY)CONSTRUCTION FENCE. THE TEMPORARY FENCE SHALL BE CONSTRUCTED OF 6' HIGH CHAINLINK FABRIC AND IS TO BE REMOVED AT THE END OF CONSTRUCTION. LAYDOWN AREA IS TO BERESTORED TO ITS ORIGINAL CONDITION AFTER FENCE REMOVAL.

7. SURVEY INFORMATION SHOWN WAS CREATED FROM RECORD INFORMATION AND DOES NOTCONSTITUTE A LEGAL BOUNDARY SURVEY.

8. THESE PLANS DO NOT ADDRESS THE SAFETY AND STABILITY OF THE STRUCTURE DURINGASSEMBLY AND ERECTION, WHICH ARE THE RESPONSIBILITY OF THE ERECTOR, BASED ON THEMEANS AND METHODS CHOSEN BY THE ERECTOR.

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE PROJECT SCOPE OF WORKDEFINED UNDER THE REQUEST FOR PROPOSAL (RFP) FOR THIS PROJECT AND ALL ASSOCIATEDATTACHMENTS AND DOCUMENTS PROVIDED.

THE RFP AND ALL ASSOCIATED DOCUMENTS SHALL DEFINE THE COMPLETE PROJECT SCOPE OFWORK. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL DOCUMENTS AND ISSOLELY RESPONSIBLE FOR ALL WORK.

ALL DOCUMENTS INCLUDED WITHIN THE PROJECT REQUEST FOR PROPOSAL ARE REQUIREDFOR THE COMPLETE PROJECT SCOPE OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLEFOR ALL WORK (EQUIPMENT, MATERIAL, INSTALLATION, TESTING, ETC.) INDICATED IN ALLDOCUMENTS. THE RFP, VERIZON NETWORK STANDARDS AND PROJECT ADDENDUMS ANDCLARIFICATIONS ARE COMPLEMENTARY TO EACH OTHER. THE FORMAT OF THE SPECIFICATIONSAND DRAWING NUMBERING PER DISCIPLINE IS NOT INTENDED TO IMPLY SEGREGATION OF SUBCONTRACTOR WORK. CONTRACTOR SHALL ASSIGN ALL SUB CONTRACTOR WORK AND VERIZONWILL NOT ACCEPT ANY CHANGE ORDERS FOR INTERNAL CONTRACTOR WORK ASSIGNMENTS.

CONTRACTOR SHALL BE RESPONSIBLE FOR DISTRIBUTING ALL RFP DOCUMENTS TO THEIR SUBCONTRACTORS. ALL RFP DOCUMENTS ARE REQUIRED TO INDICATE THE PROJECT SCOPE OFWORK. PARTIAL SUB CONTRACTOR DOCUMENT PACKAGES ARE HIGHLY DISCOURAGED.

IN THE EVENT OF A CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, REFERENCEDSTANDARDS, VERIZON STANDARDS, OR AGREEMENT TERMS AND CONDITIONS THE ARCHITECT/ENGINEER SHALL BE CONTACTED FOR FORMAL INTERPRETATION OF THE REQUIREMENTS. THECONTRACTOR SHALL BE DEEMED TO HAVE PROVIDED THE DETAILED AND EXTENSIVEINTERPRETATION. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECT/ ENGINEERINTERPRETATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO VERIZON.

2. ALL ANTENNAS MUST BE PIM TESTED WITHIN 48 HOURS OF THEM BEING RECEIVED BY THEINSTALLATION CONTRACTOR. THOSE RESULTS MUST BE SENT BACK TO THE VERIZONCONSTRUCTION ENGINEER AND EQUIPMENT ENGINEER WITHIN THE SAME 48 HOURS. IF YOUMISS THE 48HR TIMELINE AND THE ANTENNAS DO NOT PASS UPON INSTALLATION, YOURCOMPANY WILL BE CHARGED FOR THE COST OF THE ANTENNAS FOR REPLACEMENT.

3. ALL LOADS MUST BE SECURED PROPERLY TO THE VEHICLE OR TRAILER. VERIZON WILL PASSALONG THE COST OF ANY REPLACEMENTS DUE TO DAMAGE OR LOSS WHETHER IT IS NEW ORUSED.

1. CONTRACTOR TO INSTALL ANTENNAS, MOUNTS AND TOWER HARDWARE PER MANUFACTURER'SRECOMMENDATIONS (OR AS REQUIRED BY THE OWNER/PROVIDER).

2. ALL BOLTS SHALL BE TIGHTENED PER AISC REQUIREMENTS.

3. ANY GALVANIZED SURFACES THAT ARE DAMAGED BY ABRASIONS, CUTS, DRILLING OR FIELDWELDING DURING SHIPPING OR ERECTION SHALL BE TOUCHED-UP WITH TWO COATS OF COLDGALVANIZING COMPOUND MEETING THE REQUIREMENTS OF ASTM A780.

4. ANTENNA MOUNTS SHALL NOT BE USED AS A CLIMBING DEVICE. WORKERS SHALL ALWAYS TIEOFF TO AN APPROVED CLIMBING POINT.

5. SEE ALSO GENERAL ANTENNA NOTES ON SHEET RF1 (IF APPLICABLE).

1. CONTRACTOR TO INSTALL MAIN OVP, SECTOR BOXES, REMOTE RADIO HEADS, TOWER MOUNTEDAMPLIFIERS, AND/OR DIPLEXERS PER MANUFACTURER'S RECOMMENDATIONS.

2. ALL BOLTS SHALL BE TIGHTENED PER AISC REQUIREMENTS.

3. ANY GALVANIZED SURFACES THAT ARE DAMAGED BY ABRASIONS, CUTS, DRILLING OR FIELDWELDING DURING SHIPPING OR ERECTION SHALL BE TOUCHED-UP WITH TWO COATS OF COLDGALVANIZING COMPOUND MEETING THE REQUIREMENTS OF ASTM A780.

1. REQUIRED ADDITIONAL COAX PORTS TO BE ADDED AS NEEDED BY CONTRACTOR.

2. ANY ADDITIONAL COAX PORTS TO BE INSTALLED BELOW THE EXISTING, WHERE POSSIBLE.

3. CONTRACTOR TO INVESTIGATE INTERIOR OF SHELTER/EQUIPMENT ROOM FOR CLEARESTPENETRATION POINT.

4. ADDITIONAL COAX PORTS TO BE INSTALLED PER INDUSTRY STANDARDS.

HYBRID & COAX CABLES EXISTING EASEMENT

DC POWER LEASE AREA

FIBER ACCESS/UTILITY EASEMENT

ANTENNAS NEW WORK/UTILITY EASEMENT

PENETRATIONS WALL HATCH

RRH/BBU EXISTING

VIEW OF RRH UNITS(EQUIPMENT SHELTER)

VIEW OF EXISTING ROOF MOUNT ARRAY(LOOKING NORTHWEST)

VIEW OF EXISTING ANTENNAS

EXISTING 31'-11"ROOF MOUNT ARRAY

(3) EXISTING VERIZON RRH UNITS(TO BE REMOVED)

VIEW OF EXISTING COAX PORT(EQUIPMENT SHELTER)

(18) EXISTING VERIZON 7 8"Ø COAX CABLES AND(1) EXISTING VERIZON HYBRID CABLE(TO REMAIN)

(3) EXISTING VERIZONRACK MOUNTED RRH UNITS(TO BE REMOVED)

(12) EXISTING VERIZON ANTENNAS((6) TO BE REMOVED)

(1) EXISTING VERIZON MAIN OVP UNIT(TO REMAIN)

Page 3: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

C1

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

SITE PLAN

SITE PLAN

NORTH

16'-0"

SCALE: 116" = 1'-0"

16'-0" 0

4'8'12'

1. INFORMATION SHOWN BELOW FOR DEPICTION PURPOSESONLY. ALL DATA GATHERED FROM PUBLIC RECORDS ANDGENERATED FROM AERIAL IMAGES AND SITE VISITS.INFORMATION DOES NOT CONSTITUTE A LEGAL BOUNDARYSURVEY AND SHOULD NOT BE USED FOR SURVEYING OROTHER RELATED PURPOSES.

2. SITE PLAN DATA AS SHOWN IS BASED UPON A LIMITED SITEMAPPING OF THE SURROUNDING AREA AND ARCHIVED SURVEYDOCUMENTS. DATA AS SHOWN IS FOR REFERENCE ONLY.CONFIRMATION AND PROOF OF LEASE AREA AND/OREASEMENTS IS BEYOND THE SCOPE OF THIS PROJECT.

1. EXISTING UNDERGROUND UTILITIES ARE BELIEVED TO BEPRESENT THROUGHOUT THE SITE. EXACT LOCATIONS ARE NOTCONFIRMED NOR PROVEN BY THIS DOCUMENT. CONTRACTORTO CONDUCT LINE LOCATES PRIOR TO CONSTRUCTION.

(6) NEW VERIZON RRH UNITS,((2) PER SECTOR)

SEE DETAIL .A

C1 C4

(6) NEW VERIZON PANEL ANTENNAS((2) PER SECTOR)

(12) EXISTING VERIZON ANTENNAS((6) TO BE REMOVED)

(3) EXISTING VERIZON RRH UNITS RACKMOUNTED WITHIN EQUIPMENT SHELTER(TO BE REMOVED)

(1) EXISTING VERIZON MAIN OVP UNIT WALLMOUNTED WITHIN EQUIPMENT SHELTER(TO REMAIN)

EXISTING VERIZON EQUIPMENT SHELTER

EXISTINGLANDSCAPING

EXISTINGPARKING

AREA

EXISTING VERIZON 31'-11"ROOF MOUNT ARRAY

(18) EXISTING VERIZON 7 8"Ø COAX CABLES AND(1) EXISTING VERIZON HYBRID CABLE(TO REMAIN)

(6) EXISTING VERIZON 6"Ø U.G. CONDUITS(TO REMAIN)

A/C

A/C

(3) EXISTING VERIZON RRH UNITS(TO BE REMOVED)

(1) EXISTING VERIZON MAIN OVP UNIT(TO REMAIN)

(1) EXISTING VERIZON ACCESS LADDER

EXISTING VERIZON COAX PORT350° AZIM

UTH

110° AZIMUTH

230° AZIM

UTH

EXISTINGBUILDING

(1) NEW VERIZON COMMSCOPE POWERSHIFTRACK MOUNTED WITHIN EQUIPMENT SHELTER

Page 4: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

C2

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

ELEVATIONS

C.O.R. = CENTER OF RADIATION

A.L. = ATTACHMENT LEVEL

B.T. = BOTTOM TIP LEVEL

T.T. = TOP TIP LEVEL

A.G.L. = ABOVE GRADE LEVEL

B.O.B.P. = BOTTOM OF BASE PLATE

T.O.S. = TOP OF STRUCTURE

F.F. = FINISHED FLOOR

EXISTING EAST ELEVATIONSCALE: N.T.S.

NEW EAST ELEVATIONSCALE: N.T.S.

GRADE

GRADE0'-0"

C.O.R.25'-6"

T.O.S.31'-11"

F.F.2'-0"

(6) NEW VERIZON PANEL ANTENNAS

GRADE

(6) NEW VERIZON RRH UNITS,((2) PER SECTOR)

(12) EXISTING VERIZON ANTENNAS((6) TO BE REMOVED)

EXISTING VERIZON 31'-11"ROOF MOUNT ARRAY

(3) EXISTING VERIZON RRH UNITS(TO BE REMOVED)

(1) EXISTING VERIZON MAIN OVP UNIT(TO REMAIN)

EXISTING VERIZON EQUIPMENT SHELTER(18) EXISTING VERIZON 7 8"Ø COAX CABLES AND(1) EXISTING VERIZON HYBRID CABLE(TO REMAIN)

(6) EXISTING VERIZON 6"Ø U.G. CONDUITS(TO REMAIN)

EXISTING VERIZON 31'-11"ROOF MOUNT ARRAY

GRADE0'-0"

C.O.R.25'-6"

T.O.S.31'-11"

F.F.2'-0"

C.O.R.26'-2"

Page 5: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

C3

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

SHELTER MAPPING

EXISTING LIGHT FIXTURE,TYP.

19'-1

" (IN

TER

IOR

)

12'-8" (INTERIOR)

A

EXISTING CABLE TRAY,TYP.

BATTERIES: (24) ABSOLYTE GNB ABSOLYTE GP

TYPE: 100G21 1000 AMPERE HRS, 8 HRS. TO 1.75 VPCINSTALLATION DATE: 2/27/2014

TYPE: GE MODEL# NE100AC24ATEZ

(5) RECTIFIERES (3) OPEN

TYPE: GE MODEL#: NE030DC48A

(5) CONVERTERS (3) OPEN

HVAC

BATTERY RACK

COAX PORT

ACCESS DOOR

TELCO BOARD

DC POWER DISTRIBUTION CENTER

TEMPERATURE CONTROL

FIRE EXTINGUISHER

AUTOMATIC TRANSFER SWITCH

VENT

FIBER RACK

4812 MOTOROLA

E-NODE-B (BOTTOM)

4" PLUG

UBS RACK

EMPTY RACK

SWITCH

FIRST AID

MSDS

MAIN OVP UNIT

RRH UNITS (TO BE REMOVED)BBU UNITS

NEW COMMSCOPE POWERSHIFT

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

R

S

T

U

13'-8"

W

4'-1"

7"

2'-0" 2'-1" 2'-6" 1'-5"

4"

2'-4

"2'

-0"

1'-6

"4'

-4"

2'-7

"

6"

1'-8

"3'

-10"

3'-9

"

1'-2"

1'-4"

6"

2'-11" 2'-0" 4'-0" 9"

5"

2'-8

"

6"

3'-0

"2'

-8"

2'-8

"

1'-0

"

2'-1

1"

7"

2'-8

"

1'-1

0"

2'-6" 1'-3"

2'-2" 2'-0" 3'-3"

1'-5" 3'-10"

1'-1

0"2'

-2"

7'-9

"

1'-3" 4'-0"2'-11"2'-5"2'-1"

1'-6

"1'

-6"

A

B

C

D

E

F

G

H

J

K

M

N

L

P

Q

R

S

2'-5

"

P

U

T

X

V

SHELTER MAPPINGSCALE: N.T.S.

GRID LINES ARE SHOWN @ 12" O.C.

NORTH

REFLECTED CEILING PLANSCALE: N.T.S.

NORTH

BATTERY RACK

L

DC POWER DISTRIBUTIONF

1. REQUIRED ADDITIONAL COAX PORTS TO BE ADDED AS NEEDED BY CONTRACTOR.

2. ANY ADDITIONAL COAX PORTS TO BE INSTALLED BELOW THE EXISTING, WHERE POSSIBLE.

3. CONTRACTOR TO INVESTIGATE INTERIOR OF SHELTER/EQUIPMENT ROOM FOR CLEARESTPENETRATION POINT.

4. ADDITIONAL COAX PORTS TO BE INSTALLED PER INDUSTRY STANDARDS.

V

W

X

WALL MOUNTED MAIN OVP UNITV

B

FIBER RACK & BBU UNITSX

(3) EXISTING VERIZON RACKMOUNTED RRH UNITS(TO BE REMOVED)

ENLARGED COAX PORT LAYOUTSCALE: N.T.S.

(2) 7 8"Ø COAX CABLES

(2) 7 8"Ø COAX CABLES(1) HYBRID CABLE

(2) 7 8"Ø COAX CABLES

(6) 6"Ø CONDUITS

(4) 7 8"Ø COAX CABLES

(4) 7 8"Ø COAX CABLES(4) 7 8"Ø COAX CABLES

C

N E-NODE-B & RRH UNITSW

Y

Y

YY

NEW COMMSCOPE POWERSHIFTY

Page 6: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

C4

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

DETAILS &RRH HYBRID CABLE

DIAGRAM AND CHART

RRH= REMOTE RADIO HEAD

PDF= POWER DISTRIBUTION FRAME

LTE= LTE PANEL ANTENNA

AWS= AWS PANEL ANTENNA

RRH HYBRID CABLE DIAGRAM AND CHARTSCALE: N.T.S.

FROM (RRH) TO (ANTENNAS)

AN

TEN

NA

JUM

PER

S SECTORCABLE/COAX

SIZE (NOMINAL)CABLE/COAX(QUANTITY)

ESTIMATEDCABLE/COAX

LENGTHX 1

2"Ø 12 CUT TO FIT

Y 12"Ø 12 CUT TO FIT

Z 12"Ø 12 CUT TO FIT

FROM (MAIN OVP) TO (RRH)

RR

H J

UM

PER

S

SECTORCABLE/COAX

SIZE (NOMINAL)CABLE/COAX(QUANTITY)

ESTIMATEDCABLE/COAX

LENGTH

XHYB 1X1 1 ~5'

HYB 1X1 1 ~5'

YHYB 1X1 1 ~5'

HYB 1X1 1 ~5'

ZHYB 1X1 1 ~5'

HYB 1X1 1 ~5'FROM (MAIN OVP) TO (MAIN OVP)

MA

INTR

UN

K SECTORCABLE/COAX

SIZE (NOMINAL)CABLE/COAX(QUANTITY)

ESTIMATEDCABLE/COAX

LENGTH- HYB 6X12 2 EXISTING

REMOTE RADIOHEAD

ANTENNAMOUNT PIPE

REMOTE RADIOHEAD

ANTENNAMOUNT PIPE

REMOTE RADIOHEAD

ERICSSON 4449 & 8843REMOTE RADIO HEADCONNECTION DETAILSCALE: 1/2" = 1'-0"

AC1 C4

REMOTE RADIOHEAD

ANTENNAMOUNT PIPE

REMOTE RADIOHEAD

ANTENNAMOUNT PIPE

REMOTE RADIOHEAD

ERICSSON 4449 & 8843REMOTE RADIO HEADCONNECTION DETAILSCALE: 1/2" = 1'-0"

AC1 C4

238"Ø MOUNTING

POLE

COAX CABLE AND JUMPER (TYP.) SEECOAX CABLE SCHEDULE.

5

7

10

11

9

5

7

3

4

65

6

4

6

56

5

5

7

5

6

4

7

5

6

4

2

8

7

56

56

5

11

10

7 5

ANTENNA ATTACHMENT DETAILSCALE: N.T.S.

ITEM PART NO. QTY. DESCRIPTION

601553-1 2 BRACKET, CLAMP

601539-1 1 ADAPTER, POLE

802355-4 1 ADAPTER, POLE LOWER

ROD190003 4 12" x 7" THREADED ROD

WSH150003 14 12" SPLIT WASHER

NUT150001 12 12" HEX HEAD NUT

BLT140002 6 12" x 1" HEX HEAD BOLT

601730-1 1 BRACKET, DOWNTILT POLE

601735-1 1 BRACKET, DOWNTILT, ANTENNA

WSH150006 2 516" SPLIT WASHER

BLT140004 2 516" HEX HEAD BOLT

10.75 LBS

1

2

3

4

5

6

7

8

9

10

11

Page 7: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

RF1

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

ANTENNA INFORMATION

1. CONTRACTOR SHALL NOT SUBMIT BIDS OR PERFORM CONSTRUCTION WORK ON THIS PROJECT WITHOUT ACCESS TO THE CURRENT COMPLETE SETOF DRAWINGS LISTED IN THE TITLE-SHEET INDEX.

1. ALL EXISTING EQUIPMENT & COAX TO BE GROUNDED PER VERIZON GROUNDING SPECS

ATTACH LEVEL(COR)

AZIMUTHS(DEG., TN) ANTENNA TYPE ANTENNA

QUANTITY MOUNT TYPECOAX (QUANTITY)

SIZE (NOMINAL)ESTIMATED COAX

CABLE LENGTHMECHANICALDOWN TILT

25'-6"350°110°230°

ANTEL LPA-80063/44' PANEL ANTENNA

6(EXISTING)

PIPE MOUNTS(EXISTING)

(18) 7 8"Ø(EXISTING)

+(1) HYBRID CABLE

(EXISTING)

SEE SHEET C4FOR COAX

DESIGN

REFER TORFDS

26'-2" COMMSCOPE NHH-65B-R2B6' PANEL ANTENNA

6(NEW)

1. FOR EXACT ANTENNA INFORMATION REFER TO THE RF DESIGN.

2. ALL NEW COAX SHALL BE INSTALLED ON EXISTING CABLE TRAY.

3. ALL UNUSED COAX SHALL BE REMOVED.

4. CONTRACTOR TO USE EXISTING COAX FOR NEW ANTENNAS.

5. CONTRACTOR TO INSTALL DIPLEXERS IN SHELTER AS REQUIRED BY RF DESIGN. (IF APPLICABLE)

1. CONTRACTOR TO VERIFY MECHANICAL DOWNTILT WITH FINAL SMR/RF ENGINEER.

2. DUAL POLAR ANTENNAS REQUIRE TWO RUNS OF COAX PER ANTENNA.

3.

4. CONTRACTOR TO PROVIDE AS BUILT FOR THE LENGTH OF CABLES UPON COMPLETION OF INSTALLATION.

5. CONTRACTOR TO PROVIDE FINAL CABLE LENGTHS AND RETURN LOSSES FOR ALL CABLES.

6. ALL AZIMUTHS REFERENCE TRUE NORTH. CONSULT REQUIRED QUADRANGLE MAP FOR NECESSARY MAGNETIC DECLINATION.

ATTACH LEVEL(COR)

AZIMUTHS(DEG., TN) ANTENNA TYPE ANTENNA

QUANTITY MOUNT TYPECOAX (QUANTITY)

SIZE (NOMINAL) NOTES

25'-6"350°110°230°

ANTEL BXA-185063/8CF4' PANEL ANTENNA

3(EXISTING)

PIPEMOUNTS

(EXISTING)

(18) 7 8"Ø(EXISTING)

+(1) HYBRID CABLE

(EXISTING)

TO BE REMOVED

ANDREW DBXNH-6565A-VTM4' PANEL ANTENNA

3(EXISTING) TO BE REMOVED

ANTEL LPA-80063/44' PANEL ANTENNA

6(EXISTING) TO REMAIN

1. ALL EXISTING AZIMUTHS REFERENCE TRUE NORTH.

2. ALL EXISTING AZIMUTHS ARE APPROXIMATE AND BASED ON THE RFDS PROVIDED BY VERIZON.

3. ALL EXISTING AZIMUTHS REFERENCE DATA COLLECTED FROM A RECENT SITE VISIT AND DIFFERS FROM THE INFORMATION PROVIDED IN THE RFDS.

C.O.R. =

25'-6"

230° AZIM

UTH

EXISTING ANTENNA SECTION @ 25'-6"SCALE: N.T.S.

NORTH NORTH

NEW ANTENNA SECTION @ 26'-2"SCALE: N.T.S.

90°

180°

270°

135°225°

315° 45°

C.O.R. = 25'-6"110° AZIMUTH

C.O

.R. = 25'-6"

350° AZIMU

TH

X-1

Y-4

Z-4

(1) EXISTING VERIZON MAIN OVP UNITS(TO BE REMAIN)

X-2

X-3 X-4

(12) EXISTING VERIZON PANEL ANTENNAS((6) TO BE REMOVED)

(3) EXISTING VERIZON RRH UNITS(TO BE REMOVED)

Y-1

Y-2

Y-3Z-3

Z-2

Z-1 C.O.R. =

26'-2"

230° AZIM

UTH

90°

180°

270°

135°225°

315° 45°

C.O.R. = 26'-2"110° AZIMUTH

C.O

.R. = 26'-2"

350° AZIMU

TH

Y-1

Z-1

(6) NEW VERIZON PANEL ANTENNAS

(6) NEW VERIZON RRH UNITS

(1) EXISTING VERIZON MAIN OVP UNITS

X-1

X-2

X-3

X-4

Y-2

Y-3

Y-4Z-2

Z-3

Z-4

(6) EXISTING VERIZON PANEL ANTENNAS

Page 8: Three (3) RRH's removed from equipment shelter on CSP TAMLIN · 03/03/20 - 5110 tamlin road el paso county 3/3/2020 2:47 pm csp tamlin sp1 existing lease rrh/bbu antennas fiber dc

3131 SOUTH VAUGHN WAY, SUITE 550AURORA, COLORADO 80018

APP

RO

VED

FO

R C

ON

STR

UC

TIO

N

PROJECT NAME:

BYD

ESC

RIP

TIO

NR

EV

SAVE DATE:

SHEET TITLE:

DAT

E

SHEET NUMBER:

CH

K

PROJECT ADDRESS:

DESIGNED FOR:

DES

IGN

ED

BY:

BK

T0

03/0

3/20

-

5110 TAMLIN ROAD

EL PASO COUNTY

3/3/2020 2:47 PM

CSP TAMLIN

RF2

EX

ISTI

NG

LEA

SER

RH

/BBU

AN

TEN

NAS

FIB

ERD

CH

YB

RID

CAB

LES/

NEW

WO

RK/

WAL

LE

XIS

TIN

G

EA

SE

MEN

TA

REA

PO

WER

CO

AXE

AS

EM

ENT

HAT

CH

ANTENNA CUT SHEET(S)