2
Overview Active Energy-meter for three phase four wire alternating current with a 7 digit counters (No decimals. The meter comes standard with a short terminal cover. It can be supplied with a extended cover on request. • Load bar indication • External magnetic influence (Arrow points to number (1) on display) • Green back light display for ease of reading. • Pulse output. (SO 100 imp/kWh) • Supplied by Autometers Systems Ltd a quality assured company (IS 9001) • Solar PV generation meter HXE34 MID Approved ( Appendix “B” and “D”) Three phase Four wire kWh meter 230/400 Volt, 50 Hz, 10-100 Amp. LED Energy Indicator HXE34 Features Display Unit ID Active Energy kWh Energy Import Bar Indication Indicating Load L1, L2, L3 Indicating voltage lines Green back light LCD Display MID Certification Number Chart Indicating Load (Bar Indication) Extended terminal cover fitted L1, L2, L3 illuminating indicating voltage lines present Connection Diagram Short Terminal Cover (extended on Large Cover available) Bar Indication

Three phase Four wire kWh meter

Embed Size (px)

Citation preview

Page 1: Three phase Four wire kWh meter

OverviewActive Energy-meter for three phase four wire alternating current with a 7 digit counters (No decimals. The meter comes standard with a short terminal cover. It can be supplied with a extended cover on request.

• Load bar indication • External magnetic influence (Arrow points to number (1) on display) • Green back light display for ease of reading. • Pulse output. (SO 100 imp/kWh) • Supplied by Autometers Systems Ltd a quality assured company (IS 9001) • Solar PV generation meter

HXE34 MID Approved ( Appendix “B” and “D”) Three phase Four wire kWh meter230/400 Volt, 50 Hz, 10-100 Amp.

LED Energy Indicator

HXE34 Features

Display

Unit ID

Active Energy kWh Energy Import

Bar Indication Indicating Load

L1, L2, L3 Indicating voltage lines

Green back light LCD Display

MID Certification Number

Chart Indicating Load (Bar Indication)

Extended terminal cover fitted

L1, L2, L3 illuminating indicatingvoltage lines present

Connection Diagram

Short Terminal Cover (extended on Large Cover available)

Bar Indication

Page 2: Three phase Four wire kWh meter

HXE34 Three phase Four wire kWh meter 230/400 Volt, 50 Hz, 10-100 Amp.

Technical Data Data in compliance with EN 62053-21, EN62053-31, EN62056-21, DIN 43857-3

Autometers Systems Limited 4B Albany Road, Chorlton-cum-Hardy, Manchester, M21 0AW Tel: +44 (0) 161 861 9056 Fax: +44 (0) 161 881 3745 www.autometers.co.uk Email: [email protected] development is continuous and Autometers Systems Ltd reserves the right to make alterations and manufacture without notice. Products as delivered may therefore differ from the descriptions and illustrations in this publication.

Supplied by Autometers Systems Ltd, a quality assured company ( IS 9001) Publication No: HXE0512

ISO 9001Registered

QualityManagement

015

Back of meter

1 3

2

4 65

17 18

15 21

17 18

15 21

13 20

235 mm

1 3

2

4 65

17 18

15 21

17 18

15 21

13 20

315 mm

Fixing Bracket

1 3

2

4 65

17 18

15 21

17 18

15 21

13 20

All Terminal diameter for cable entry: 8 mm

L1 L2

Maximum cable size: 25mm²

L3 NEUTRAL

Terminals 20-2:1 Pulse Out Put

Connection Diagram Bottom of meter 240/400v 50Hz 10-100amp

Terminals 20 and 21 Pulse Output 100imp/kWh

3 phase 4 wire 100amp direct connected kWh meter

2 5 8 11 1 3 4 6 7 9 10 12 + - 20 21

L1

L2

L3

N

L1

L2

L3

N

MAINS

LOAD

Pulse Output

Power Bar Indication

- ≥ 0.01 kw- - ≥ 0.3 kw- - - ≥ 3.0 kw- - - - ≥ 10.0 kw- - - - - ≥ 20.0 kw- - - - - - ≥ 30.0 kw- - - - - - - ≥ 40.0 kw- - - - - - - - ≥ 60.0 kw

Arrows indicate the direction of power

HXE

3419

412

Side of meter

Measuring scope Rated voltage Voltage range Rated Frequency Rate Indicator LED Communication Communication Accuracy class Basic current Maximum current Minimum current Starting current Power consumption Tamper detection Display Operating temperature range Humidity operating range Degree of protection Meter life Weight Dimensions (L x W x H) Meter cover Meter base Terminal Box cover

Active energy, MD 3x 230 v (230/400v) 0.8UN~1.2UN 50 Hz 1000 imp/k Wh Optical port, RS485 with EN 62056-21 SO Pulse Output 100imp/kWh C1.B 10 A 100A 150 mA 15 mA Voltage circuit < 0.56w Apparent Power at UN <2.361VA Current circuit <0.025VA External magnetic detection 7 digits LCD, 7 integers -40˚ + 70˚C 95% IP54 No less than 15 years Approximate 1.485KG 262 mm x 170 mm x 70 mm (Short terminal cover) Transparent PC Glass fibered PC Glass fibered PC

170 mm

262 mm

Extended Terminal Cover

Small Terminal Cover

Terminals 3 mm diameter

70 mm

150 mm