8
PROGNOST®-NT V18 Enhancements to Version 17 Automated Reports User-friendliness Software Upgrade

TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

  • Upload
    others

  • View
    9

  • Download
    2

Embed Size (px)

Citation preview

Page 1: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

PROGNOST®-NT V18Enhancements to Version 17

Automated Reports User-friendlinessSoftware Upgrade

Page 2: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion
Page 3: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

Why upgrade your software?

It is essential that the monitoring technology of your rotating

equipment is always up to date. The annual Upgrade of your

PROGNOST®-NT software delivers all advantages of our ongo-

ing product developments.

In this brochure, we will introduce you to all of our important

innovations and feature enhancements which will help you

carry out your monitoring tasks faster and more effectively.

Please note: Some new functions require appropriate system

capabilities. If you are using older Monitoring Units, some

new functions may have to be deactivated or may only be

used to a limited extent.

All Upgrades at a glance

User benefits

Enhancements to improve the ease of use of your

PROGNOST®-NT software.

Automated compilation of meaningful reports

Machine Protection Report

Cylinder Diagnostic Report

Optimized diagnostics for Rider Ring Wear

New quick access functions via context menus

Seperate entry for filtered signal

Optimized User-friendliness

System improvements

Enhancements for ensuring IT security and future usability of

the PROGNOST®-NT system.

Enhanced system performance

Software version for 64 Bit operating systems

New system requirements

Page 4: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

Overview of the automatically generated reports with indication

of affected components

Automated compilation of meaningful reports

Beginning in Version 16, the first step of this integration was

done with the Condition Reports. Those manually generated

reports are supplemented in Version 18 with the automated

compiled Machine Protection and Cylinder Diagnostic

Reports. The data and analyses behind these reports are

based on decades of monitoring expertise of the PROGNOST

Systems experts.

Differences between both types of reports are the type of

request and the structure. To avoid overloading the Monitor-

ing Unit data storage, a maximum limit of 200 reports per

category is set as default. When the limit is exceeded, the

oldest reports will be deleted and substituted with the new-

est.

Machine Protection Reports

The automated creation of Machine Protection Reports is

initiated by a Safety Limit violation (ALERT or SHUTDOWN).

Contents of the report are possible causes of the ALERT/

SHUTDOWN. Also the online signal together with the

analysis of the last three revolutions of the critical signal are

included. This provides all information to efficiently inspect

and replace the affected component. The report is also a

failure record to be saved locally and forwarded by mail as a

PDF file.

Cylinder Diagnostic Report

The Cylinder Diagnostic Report is triggered manually. The

report lists all important performance details and shows also

the individual p-V diagram analysis of each compression

chamber. Users receive a complete overview of the main

performance figures and findings. Detected failures such as

valve failures or packing leakages are pinpointed based on

the PROGNOST® pattern recognition technology.

Page 5: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

Separate entry for filtered signal

The result of a filtered signal is from now shown as own

signal line and list entry in the online-view. It will be updated

automatically with the signals and is available until the

online-view is closed or a new filtering for the source signal

is done.

New quick access functions with context menus

A few function is available via the machine tree and the

online-view to enhance the software usability. This is espe-

cially usefull for the following points.

Open 3D waterfall plot via machine tree

Open online p-V diagram via machine tree

Show inertia load in the online-view

Optimized diagnostics for Rider Ring Wear

New function to straighten the trend plot of the Rider Ring

Wear analysis and generate a separate trend line. This ad-

ditional trend line allows a convenient monitoring. This deliv-

ers closer inspection details to set more acurate warning

thresholds for the Rider Ring Wear diagnostics.

Trend of Rider Ring Wear

Machine Measuring Point Data name TAG-Name Value Unit11KB201 V Cor. P2 Vib. cross head slide 11XT_113 0.02747 g11KB201 V Cor. P2, Filt Filt 11XT_113 -0.1160 g

Machine Measuring Point Data name TAG-Name Value Unit11KB201 V Cor. P2 Amplitude spectrum 11XT_113 0.00076 g11KB201 V Cor. P2, Filt Amplitude spectrum 11XT_113 0.001�3 g

-2�

-20

-1�

-10

-�

0

10

1�

20

27g

0 1� 30 4� 60 7� �0 10� 120 13� 1�0 16� 1�0 1�� 210 22� 240 2�� 270 2�� 300 31� 330 � CA 360

TDC BDC TDC �n line

0.00

0.0�

0.10

0.1�

0.20

0.2�

0.30

0.3�

0.42g

0.00 0.30 0.60 0.�0 1.20 1.�0 1.�0 2.10 2.40 2.70 3.00 3.30 3.60 3.�0 4.20 4.�0 4.�0 �.10 �.40 �.70 6.00 6.30 ��� 6.�0

FFT Anal�sis

Page 6: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

Enhanced system performance

Growing demands regarding the visualization software are

a result of changing operating systems and new computer

generations.

This effects two major changes within the VISU 18 software.

Software Version for 64 Bit operating systems

Starting with version 18 a own software version for 64 Bit

computers is available. This helps especially if storage inten-

sive work processes need to be executed, what will be more

effective using the 64 Bit technology.

New System requirements

Starting with VISU 18 Windows® XP and Windows® Vista are

no longer supported. Windows® 7 (SP1) is the minimum re-

quirement to use the VISU functions in an effective manner.

New designs for icons and toolbars

Optimized User-friendliness

Icons and toolbars have been overhauled to support the

intuitive usage of the PROGNOST® software. To ensure a clear

and meaningful machine icon, the standards ISO 10628 and

ISO 14617 are used as reference.

Regarding the trayicon in the status bar a new funcion is

integrated which allows to switch between one icon for all

machines to one icon for every connected machine.

Page 7: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion
Page 8: TI PROGNOST-NT Upgrade V17-V18 01 EN · and meaningful machine icon, the standards ISO 10628 and ISO 14617 are used as reference. Regarding the trayicon in the status bar a new funcion

www.prognost.com

PROGNOST Systems GmbH

Daimlerstraße 10

48432 Rheine

Germany

+49 (0)59 71 - 8 08 19.0

+49 (0)59 71 - 8 08 19.42

[email protected]

PROGNOST Systems, Inc.

1018 Hercules Ave.

Houston, TX, 77058

USA

+1 - 281 - 480 - 9300

+1 - 281 - 480 - 9302

[email protected]