61
TIA Portal V14 SP1 Technical slides Unrestricted © Siemens AG 2017

TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

  • Upload
    lekhanh

  • View
    278

  • Download
    12

Embed Size (px)

Citation preview

Page 1: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

TIA Portal V14 SP1 Technical slides

Unrestricted © Siemens AG 2017

Page 2: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA updater: Fast mass update

Openness: Ex/Import HW +IO via AutomationML

ProDiag: Criteria analysis for S7-Graph

Safety: Consistent Hardware- and Software Upload

Option handling with S7-1500F

F-IO-Status function block

6. TIA Portal options 2. STEP 7 - Innovations

Freely editable comments for array and UDT

New instructions

Single block comparison

User comments visible directly in the code

New technology object for SIMATIC Ident

3. WinCC - Innovations 5. System functions

Integration of SINUMERIK Operate in Runtime Advanced

OPC UA DA client for WinCC Runtime Professional

WinCC WebUX- Auto Login for WinCC RT Professional

1. Hardware configuration

Support for new hardware components

- CPU1511T(F) / CPU1515T(F)

- Power Supply 60W 24/48/60V DC HF

New functions for the operability

TIA Portal

Highlights of TIA Portal V14 SP1

March 2017 Page 2

Details

Optimized and extended

commissioning wizard

Online/offline comparison of parameter

values

4. Startdrive - Innovations

Windows 10 support

Password API

User-defined filters for cross-references

Library handling

Page 3: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

S7-1500 CPU Portfolio has been enlarged by T-CPU

Page 3

Compact

CPU

Standard

CPU

Technology

CPU

ODK-

CPU

CPU-types 1511C-1

PN

1512C-1

PN

1511F-1

PN

1513F-1

PN

1515F-2

PN

1516F-3

PN/DP

1517F-3

PN/DP

1518F-4

PN/DP

1511TF-1

PN

1515TF-2

PN

1517TF-3

PN

1518F-4

PN/DP

ODK

Interfaces

Program/

Data memory

175 KB

1 MB

250 KB

1 MB

150/225 KB

1 MB

300/450 KB

1.5 MB

500/750 KB

3 MB

1/1.5 MB

5 MB

2/3 MB 8 MB

4/6 MB

20 MB

225/225 KB

1 MB

750/750 KB

3 MB

3/3 MB 8 MB

4/6 MB

20 MB1)

Bit-Performance 60 ns 48 ns 60 ns 40 ns 30 ns 10 ns 2 ns 1 ns 60 ns 30 ns 2 ns 1 ns

Width 85mm 110mm 35mm 35mm 70mm 70mm 175mm 175mm 35mm 70mm 175mm 175mm

Positioning axis

typical 2)

maximum 3)

5

10

5

10

5

10

5

10

7

30

7

30

70

128

128

128

5

10

7

30

70

128

128

128

Motion Control

Ressources 4) 800 800 800 800 2400 2400 10240 10240 800 5) 2400 5) 10240 5) 10240

2) at 4ms Servo/IPO cycle time and 35% CPU load due to Motion Control

1

1

1

1

1

1

1

1

1

1

2 1

1

2 1

1

2 1

1

2

3

1

1

2

3

1

1

1

1

2 1

1

2

1) 20 MB additional memory for ODK application

4) Ressources for Motion Control technology objects (examples): Speed setpoint: 40; Positioning: 80; Gearing: 160; Output cam: 20; Output camtrack: 160; Measuring input: 40

3) no further TO´s applicable

March 2017

PROFINET IO with IRT 2 PROFINET IO with RT 3 PROFINET basic services 1 5) Additional Number of Cam´s: 1511T: 20; 1515T: 60; 1517T: 128 PROFIBUS

New

Page 4: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Easy handling of huge data amounts, which has to be kept retentive,

e.g. in order to save settings or parameterization data during power

off on the CPU.

Migration of S7-400 applications in factory automation is possible

Infeed of 60W into the backplane bus, integrated power balancing in

the TIA Portal, connection to 24/48/60 V DC

Energy buffering for data backup (up to 20 MB) in the CPU

Can be used with standard- and fail-safe CPUs

105mm width (can be plugged only on the left, next to the CPU)

I&M 0 … 3 („electronic rating plate“ with article number, version, etc.)

Highlights with PS 60W 24/48/60V DC HF

Customer benefits:

Page 4 March 2017

Hardware configuration

Configuration of the System Power Supply PS 60W 24/48/60V DC HF

Page 5: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Configuration in STEP 7 V14 SP1

CPU firmware: V2.1,

power supply for the CPU is done via the backplane bus

Can be used with the following S7-1500 CPUs:

CPU 1511(F/T) up to CPU 1516(F) with

article number: 6ES751x-xyy01-0AB0 (starting with FS01)

CPU 1511C and CPU 1512C (starting with FS01)

CPU 1517(F) and CPU 1518(F) starting with FS03

FS: Hardware functional state

March 2017 Page 5

Precondition for Configuration

Hardware configuration

Configuration of the System Power Supply PS 60W 24/48/60V DC HF

Page 6: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Configuration of the System Power Supply PS 60W 24/48/60V DC HF

Increased quantity structure for retentive data

Identical handling of retentive data like before

March 2017 Page 6

Page 7: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Configure all IO channels of a module in a grid

Configure all I/O channels

of a module in a grid:

All of the channels of the

ET200MP DI&DQ HF

can be configured in one

grid.

Improved overview and

helpful functions like

auto fill, copy & paste for

diagnostics & IO

parameters

March 2017 Page 7

Page 8: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Direct renaming of device names in the network and topology view

Direct renaming of device

names in the network and

topology view

Time savings thanks to

direct renaming in the

network and topology

view without opening the

device properties

Renaming via F2

shortcut, shortcut menu

or by double-clicking on

the device label

March 2017 Page 8

Page 9: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Optimized (multi-)selection via shift key for network and device editor

1st click

Shift key

+ 2nd click

Optimized selection for

network and device editor

Quick (multi-)selection of

several devices and

modules with only two

mouse clicks

Support of device and

network editor in all

views

March 2017 Page 9

Page 10: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Overview of IO tags of the complete IO station

Overview of all IO tags of

a complete IO station

Additional display for the

IO tags of the complete

IO station that are used

Display structured

according to modules for

easy assignment of the

IO tags to the hardware

March 2017 Page 10

Page 11: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Easy removal of unused GSD files

1

2

3

Easy removal of unused

GSD files in the project

Cleaning up of

references to unused

GSD files in the project

Easy removing of

unused GSDs from

project with 3 clicks

March 2017 Page 11

Page 12: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Improved zoom and overview navigation for the device and network editor

Improved zoom and

overview navigation for

the device and network

editor

The zoom function via

toolbar controls now

obtains the selected

object in the visible area

The overview navigation

shows the complete

configuration and

automatically optimizes

the display to the

available area

March 2017 Page 12

Page 13: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Hardware configuration

Easy-to-find "PROFINET I/O system" properties

Easy-to-find "PROFINET

I/O system" properties

Properties now also

become visible by

selecting the subnetwork

All of the parameters of

the subnetwork and

PROFINET I/O systems

in the overview

March 2017 Page 13

Page 14: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

HWCN editors

Wizard extension for UDP multicast with Open User Communication (OUC) S7-1500 S7-1200 S7-300/400/WinAC

Wizard extension for UDP

multicast with Open User

Communication (OUC):

Easy UDP Multicast

configuration for programmed

or configured connections with

S7-1500 incl. CM/CP

Extension for CPU internal

interfaces of S7-1500 V2.1 or

higher

March 2017 Page 14

Page 15: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA updater: Fast mass update

Openness: Ex/Import HW +IO via AutomationML

ProDiag: Criteria analysis for S7-Graph

Safety: Consistent Hardware- and Software Upload

Option handling with S7-1500F

F-IO-Status function block

6. TIA Portal options 2. STEP 7 - Innovations

Freely editable comments for array and UDT

New instructions

Single block comparison

User comments visible directly in the code

New technology object for SIMATIC Ident

3. WinCC - Innovations 5. System functions

1. Hardware configuration

Support for new hardware components

- CPU1511T(F) / CPU1515T(F)

- Power Supply 60W 24/48/60V DC HF

New functions for the operability

TIA Portal

Highlights of TIA Portal V14 SP1

March 2017 Page 15

Details

Optimized and extended

commissioning wizard

Online/offline comparison of parameter

values

4. Startdrive - Innovations

Windows 10 support

Password API

User-defined filters for cross-references

Library handling

Integration of SINUMERIK Operate in Runtime Advanced

OPC UA DA client for WinCC Runtime Professional

WinCC WebUX- Auto Login for WinCC RT Professional

Page 16: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

UDT and array comments can be changed instance-

specifically

Inheritance of defined comments by default

Multilingual support

S7-1500 S7-1200 S7-300/400/WinAC

Customer benefits

1. Display on the application

2. Use for message text

STEP 7 - Language innovations

Freely editable comments for arrays and UDTs

Function

3. Further benefits

Individual use of the

same UDTs

Unambiguous description

of array elements

March 2017 Page 16

New

Page 17: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

S7-1500 S7-1200 S7-300/400/WinAC

New

New

SCATTER* converts elementary

data types to a bit array

GATHER* converts a bit array to

an elementary data type

Expanded instructions

SCATTER_BLK and

GATHER_BLK for "array of data

type"

Converting data for

further processing

STEP 7 - Language innovations

New instructions: Scatter* / Gather*

Breaking down, processing and

status words

Example use case

March 2017 Page 17

* from FW V2.1 (S7-1500), V4.2 (S7-1200)

Page 18: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

New

0

1

2

3

4

5

6

7

0 1 2 3 4 5 6 7

x 1

Output=3.5

Input=5.5

Characteristic line is defined as

a polyline

Up to 50 points

Linear interpolation between

points

Input is mapped to

output via characteristic line

Use cases

Adaption of measured values

Linearization of actuators

with nonlinear characteristic

(e.g. compensation of valve

characteristics)

S7-1500 S7-1200 S7-300/400/WinAC

STEP 7 - Language innovations

New instructions: Polyline

March 2017 Page 18

Page 19: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

S7-1500 S7-1200 S7-300/400/WinAC

Generation of a diagnostic entry when a user-defined service life

is exceeded (in a percentage of the guaranteed read/write cycles)

Visual indicator on the CPU via the maintenance LED

Information in the user program can be evaluated via the

"GetSMCinfo" block:

Card size and memory that is already assigned

Number of write and delete processes carried out for the

card

"Service life" display of the SIMATIC memory card

RS ER MT

80%

FW

2.0

When recipes and archives are intensively used, information on

the "service life" of the card can be evaluated and the SMC card

can be swapped in advance if need be.

Field of application New

STEP 7 - Language innovations

New instruction: GetSMCinfo

March 2017 Page 19

New

Page 20: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Easy back-up of various types of

data

Type safety because different UDTs

can be assigned

Compared to Serialize/Deserialize

clearly better runtime behavior

Various types of valves can be stored

or manipulated in an array

Customer benefits

Use case

STEP 7 - Language innovations

Symbolic programming UDT1 := UDT2

The various types of UDT must have the same structure of the

individual elements.

The symbolic names may differ.

Requirements

March 2017 Page 20

S7-1500 S7-1200 S7-300/400/WinAC

New

Programming example

:=

Page 21: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Language innovations

S7-Graph: Extension function block 1/2

S7-1500 S7-1200 S7-300/400/WinAC

With introduction of the expansion function

block for S7-Graph all static variables can be

accessed generically via the InOut interface.

The created extension function block can be

called as multi- or single instance.

Customer benefits

Indexed access to the whole sequence

Access to internal parameters like - number of active steps (SAX)

- number of disturbed steps (SERRX)

- number of valid transitions (TVX)

- and so on….

Basic principle

Call „My S7-Graph FB“

My S7-Graph DB

OB, FB, FC „My S7-Graph FB“,

My S7-Graph DB

New Extension

function block

March 2017 Page 21

Page 22: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Language innovations

S7-Graph: Extension function block 2/2

S7-1500 S7-1200 S7-300/400/WinAC

1) Create S7-Graph block (from V4.0)

2) Create Extension function block*

a) Define InOut parameters to access S7-

Graph variables

b) Sample program for indexed access to

steps and transitions

c) Sample program for access of internal

parameters

3) Define extension function block as multi

instanz within the static-section of

S7-Graph block

4) Define the extension block name

within the properties of the

S7-Graph block.

Workflow 1

4

2

2a

2b

2c

3

* SCL only

March 2017 Page 22

Page 23: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Technology

SIMATIC Ident: new technology object (TO) S7-1500 S7-1200 S7-300/400/WinAC

The technology object for SIMATIC

Ident is the link between the HW

design and the SW programming

The user allocates every device with

a unique name which is also used for

programming.

Parametrization of hardware by the

technology object

Diagnostic by displaying messages

that are produced within the

application software.

Basic principle

March 2017 Page 23

Page 24: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Technology

SIMATIC Ident: Adressing scheme using TO S7-1500 S7-1200 S7-300/400/WinAC

Easiest configuration

1. Design hardware and network. Assign

RFID devices with their own name.

2. Call the TO window and select a RFID

device.

3. Adjust all parameter for the selected

RFID device/reader.

4. Select a RFID device in your

application software. Only configured

devices are shown in the drop dwon

menu.

3. Adjust parameter

1. Design the hardware 4. Select device in

function block of the

application

2. Call TO

March 2017 Page 24

Page 25: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Trace

New options for graphical representation

4

3

1

Online

Offline

2

5

1. Preview window for the illustration

and choice of the current zoom area

2. Choice of the time format for the x-

axis

3. Display format for the number

representation switch-selectable

4. Switchover between steps and linear

interpolated signal (REAL)

5. Ongoing automatic measuring

repetition

Options

Customer benefit

Better Usability

Page 25 March 2017

Page 26: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Language innovations

Collection of useful function expansions

SCL: Surrounding a code that is used

Selected code lines can be encompassed

with control structures using the "Surround

with" function.

SCL: Insert and overwrite modes

You can switch between

insert and overwrite mode

using the Ins key.

Page 26 March 2017

Insert mode Overwrite mode

"Ins key"

New

New

Page 27: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 – Editor innovations

Collection of useful function expansions

Page 27 March 2017

Individual block comparison

The detailed comparison of individual

blocks can be started directly from the

project navigation.

Offline/offline but also online/offline

Display of the tag comment

In LAD/FBD, the tag comment can be

displayed directly on the application.

Hierarchical comments can also be

displayed

New

New

Page 28: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Editor innovations

Collection of useful function expansions

Tag comment in the watch table

The defined tag comment can also be

displayed in the watch table.

Inserting a comment line in the watch table

A comment line can be inserted using the

new icon.

"Open block/PLC data type..." via F7

The F7 function can also be started within

editors using Focus.

Page 28 March 2017

New

New

Page 29: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Editor innovations

Collection of useful function expansions

"Deep export" of external sources

The export of objects as an external source

takes the UDTs defined in the interface,

multi-instances and all called blocks into

consideration.

Upgrade of the project version to the latest

version

In the Instructions task card, the project can

upgraded to the latest version to be able to

use all of the new instructions.

Update of the instructions used in a

controller

All of the instructions used for a controller

can be updated to the latest version in the

Instructions task card.

Page 29 March 2017

New

New

New

Page 30: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Editor innovations

Collection of useful function expansions

Settings for library types

Under Settings/General/Library settings, the

type cancellation of objects can be

suppressed.

Protection for unintentional cancellation

of a typified object.

Settings for user-defined help

Under Settings/General, the user can select

whether the user-defined help is to be

opened in the selected editing language.

Page 30 March 2017

Terminate connection to type

Corporate

settings

New

New

Page 31: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

STEP 7 - Editor innovations

Collection of useful function expansions

Export of PLC tags used

The export of tag tables can be limited to

the tags used in the project.

Monitoring of blocks

When monitoring blocks it will be shown

whether online values are updated.

Page 31 March 2017

Ne

w

New

New

Page 32: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA updater: Fast mass update

Openness: Ex/Import HW +IO via AutomationML

ProDiag: Criteria analysis for S7-Graph

Safety: Consistent Hardware- and Software Upload

Option handling with S7-1500F

F-IO-Status function block

6. TIA Portal options 2. STEP 7 - Innovations

Freely editable comments for array and UDT

New instructions

Single block comparison

User comments visible directly in the code

New technology object for SIMATIC Ident

3. WinCC - Innovations 5. System functions

1. Hardware configuration

Support for new hardware components

- CPU1511T(F) / CPU1515T(F)

- Power Supply 60W 24/48/60V DC HF

New functions for the operability

TIA Portal

Highlights of TIA Portal V14 SP1

March 2017 Page 32

Details

Optimized and extended

commissioning wizard

Online/offline comparison of parameter

values

4. Startdrive - Innovations

Windows 10 support

Password API

User-defined filters for cross-references

Library handling

Integration of SINUMERIK Operate in Runtime Advanced

OPC UA DA client for WinCC Runtime Professional

WinCC WebUX- Auto Login for WinCC RT Professional

Page 33: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC for Basic Panels

Collection of useful function expansions

Page 33 March 2017

Functional improvements for Basic Panel

Assignment of IP address is not limited to S7-1200 and S7-1500 anymore

USB Rescue Stick to reset Panel if connection is not possible

Siemens barcode scanners are now officially released with HMI Panels

Download Chinese/Japanese/Korean fonts to Basic Panel

(use of browser in these countries) via ProSave

Picture and text in parallel on a button

Unicode csv export of recipes on Basic Panels

USB Reset to Factory with USB stick

Creation of the USB stick

download of software

Unzip onto USB stick

Copy of Image from TIA folder into folder of USB stick

Start Basic Panel with inserted USB stick

Follow instructions

Restart the device

Available via download or from hotline

Preconditions:

USB is FAT32 formatted

Image is TIA V14 or higher

Page 34: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC for Comfort / Mobile Panel

Collection of useful function expansions

Page 34 March 2017

Functional improvements for Comfort / Mobile Panel

Uninstall WinCE applications for Comfort Panels (via ProSave)

Siemens barcode scanners are now officially released with HMI

Panels

Support of new network cameras

Unlimited usage of scripts (no system limit anymore)

Additional system functions in zone editor for Mobile

System function for restart of Comfort Panels

New supported printers:

Brother HL-5100DN (black laser)

Brother HL-L8250CDN (color laser )

Connectivity – Tested products

Support of Siemens barcode scanners

Optical handheld reading devices MV320/MV325/MV340

Update of tested network cameras

AXIS M1013, AXIS M1011

D-Link DCS-942L, D-LINK 4701E

https://support.industry.siemens.com/cs/ww/en/view/62383298

https://support.industry.siemens.com/cs/ww/en/view/19188460

Page 35: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC for Mobile Panels 2nd Generation and Runtime Advanced

Collection of useful function expansions

Page 35 March 2017

System functions for Mobile Panels 2nd Generation

Evaluation of the connection point

ShowPopUpScreen

ShowSlideInScreen

ShowLogonDialog

Log on user, log off user

VB script

General enhancements for Runtime Advanced

Camera view to display live video streams of current

network cameras over RTP/RTSP streaming protocols

and MJPEG, H264, MPEG4 codecs tested cameras

(AXIS M1013, AXIS M1011, D-Link DCS-942L, D-LINK

4701E, Siemens CCMS2025)

Extension of PDF view (Find and Copy)

License-free use of the Sm@rtServer on Runtime

Advanced (analogous to Comfort Panels)

ID 9 ID 8 ID 7

Page 36: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC Runtime Advanced

Integration of SINUMERIK Operate in Runtime Advanced

Access to SINUMERIK Operate user interface via new NC

Operate view in pictures of RT Advanced (also multitouch

operation)

Access to SINUMERIK NCU data by means of separate

SINUMERIK channel

Currently support of single-station solutions on SIMATIC IPC as

well as standard PC with Windows 7 Professional operating

system

Requires ES option SINUMERIK Integrate Create MyHMI/WinCC

as an enhancement for WinCC Advanced/Professional and RT

option SINUMERIK Integrate Run MyHMI/WinCC for operation

with WinCC Runtime Advanced

Requires SINUMERIK Operate/PCU or /PC as of version 4.8

SP1 or higher (customer-specific start of delivery scheduled for

May 2017)

Integration of SINUMERIK Operate (GUI and data)

in Runtime Advanced

March 2017 Page 36

Page 37: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC Runtime Professional

OPC UA DA Client

OPC UA DA Client

March 2017 Page 37

Page 38: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC Runtime Professional

Option WinCC/WebUX

Option WinCC/WebUX

March 2017 Page 38

Info about used licenses

Automatic Login ( “ViewOnly” for monitoring)

Use Case: information display in manufacturing hall

Page 39: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

WinCC Runtime Professional

Collection of useful function expansions

Collection of useful function expansions

March 2017 Page 39

Modal Popups with ScreenWindow

The screens, shown in screen window can be locked (no operation)

UseCase: InputMask, Messageboxes, ...

VBS Method: „SetOperationLock()“

Customizable Recipe Control

Possibility to configure the following properties:

Adapt the buttons (size and design)

Elements of table (individual symbols, also dependent from tags)

Scollbar (Style)

https://support.industry.siemens.com/cs/ww/en/view/76327375

Page 40: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA updater: Fast mass update

Openness: Ex/Import HW +IO via AutomationML

ProDiag: Criteria analysis for S7-Graph

Safety: Consistent Hardware- and Software Upload

Option handling with S7-1500F

F-IO-Status function block

6. TIA Portal options 2. STEP 7 - Innovations

Freely editable comments for array and UDT

New instructions

Single block comparison

User comments visible directly in the code

New technology object for SIMATIC Ident

3. WinCC - Innovations 5. System functions

1. Hardware configuration

Support for new hardware components

- CPU1511T(F) / CPU1515T(F)

- Power Supply 60W 24/48/60V DC HF

New functions for the operability

TIA Portal

Highlights of TIA Portal V14 SP1

March 2017 Page 40

Optimized and extended

commissioning wizard

Online/offline comparison of parameter

values

4. Startdrive - Innovations

Details Windows 10 support

Password API

User-defined filters for cross-references

Library handling

Integration of SINUMERIK Operate in Runtime Advanced

OPC UA DA client for WinCC Runtime Professional

WinCC WebUX- Auto Login for WinCC RT Professional

Page 41: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

SINAMICS Startdrive V14 SP1

Optimized and extended commissioning wizard

March 2017 Seite 41

Integration of the previously two separated wizards

for standard commissioning and the use with a

SIMATIC Motion Control axis into one wizard

Integration of the selection of telegram, brake

resistance, filter at motor-side, temperature sensor

as well as Motor selection also by code number

Page 42: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

SINAMICS Startdrive V14 SP1

Collection of useful function expansions

Seite 42 March 2017

Online/offline comparison of parameter

values

Track changes online / offline

Sensitive support for saving data

“RAM to ROM”

Message box displayed when disconnecting

from the drive (only if parameters have been

edited)

Page 43: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA updater: Fast mass update

Openness: Ex/Import HW +IO via AutomationML

ProDiag: Criteria analysis for S7-Graph

Safety: Consistent Hardware- and Software Upload

Option handling with S7-1500F

F-IO-Status function block

6. TIA Portal options 2. STEP 7 - Innovations

Freely editable comments for array and UDT

New instructions

Single block comparison

User comments visible directly in the code

New technology object for SIMATIC Ident

3. WinCC - Innovations Windows 10 support

Password API

User-defined filters for cross-references

Library handling

5. System functions

1. Hardware configuration

Support for new hardware components

- CPU1511T(F) / CPU1515T(F)

- Power Supply 60W 24/48/60V DC HF

New functions for the operability

TIA Portal

Highlights of TIA Portal V14 SP1

March 2017 Page 43

Details

Optimized and extended

commissioning wizard

Online/offline comparison of parameter

values

4. Startdrive - Innovations

Integration of SINUMERIK Operate in Runtime Advanced

OPC UA DA client for WinCC Runtime Professional

WinCC WebUX- Auto Login for WinCC RT Professional

Page 44: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

System functions

Win10-Support for TIA Portal V14 SP1 incl. V13 SP2

Supported operating systems

New

New

V13 SP2

V14 SP1

01/2020 Windows 7

10/2025 Windows 10

End of ext.

support:

Use case

project upgrade

V13 V14

Customer benefits

Long-term Microsoft Windows support with Windows 10

One shared operating system platform for TIA Portal and

"Classic products"

Project upgrade to a single-station computer :

Vxx V13 SP2 V14 SP1

March 2017 Page 44

* planned Q2/2017 * for STEP 7 / WinCC Basic also Windows 10 Home

*

Page 45: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

System functions

Password API

Protected

program

blocks

TIA Portal / STEP 7

Password prompt

via API

Integrated UI behavior:

Password prompt via dialog

KHP-PW

Central server management

with user authentication

User-specific hardware dongle

ID card with

Smartcard chip

Application examples

New

Open interface for 3rd party tools to connect to

the TIA Portal

Definition or administration of passwords in

external tools

Automatic opening of know-how-protected

blocks without entering a password

Supported protective mechanisms:

- Know-how protection for PLC objects

- Write protection for PLC objects

- Copy protection for PLC objects

Increased know-how protection because

passwords for the users are not visible/known

More convenient working with protective

mechanisms

Function

Customer benefits

Passw

ord

AP

I

March 2017 Page 45

Page 46: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

System functions

Filter options for cross-references

1 New 2

3

Example use case

As a user, I would like to find all variable write

accesses in a block greater than 1.

Workflow

1. Select all of the variables and open the

cross-references ("F11" or inspector window)

2. Define filter

3. The filter results show only multiple

accesses

Specific information is quickly found

Project-independent, can be saved and

exported

Customer benefits

Filter options

March 2017 Page 46

Page 47: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Library

Export

System functions

Translation of libraries

B1 ENG GER

B2 ENG GER

V 1.0.0

V 0.3.2

Translation

ENG CHN

Text 1 …

Text 2 …

… …

ENG GER

ENG GER

V 1.0.0

V 0.5.9

ENG GER

ENG GER

Library

B1 ENG GER CHN

B2 ENG GER ITA

V 1.0.0

V 0.3.2

ENG GER

ENG GER

V 1.0.1 ENG GER CHN

V 1.0.0

V 0.5.9

ENG GER

ENG GER

V 1.0.1 ENG GER CHN

Import

Customer benefit

Translation of a library

Translation functions available for

project and

global libraries

The import/export of texts can be

done for a complete library, for

several library elements, or an

individual library element.

Consistent handling for copy

templates and types

March 2017 Page 47

Page 48: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

System functions

Library functions – Type upgrade – With TIA Portal V14 SP1

Function

Integration of deltaobjects for existing

types

System supported integration of

changed objects into an existing

library

Customer benefit Workflow

1. The filter shows all of the types that can

be upgraded

2. The user selects the test environment

3. The system checks the prerequisites

4. The system performs the upgrade of the

selected types

Blue markings appear if the types in the PLC_1 are instantiated.

1 2 4

3

Page 48 March 2017

Page 49: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

V13 SP1-Project V14 SP1 Project

V14 SP1 Engineering Software

Project Upgrade to V14 SP1

All project versions can be accessed via side-by-side Installation of V13 SP2 and V14.

V13 SP1/SP2

(usage also with V14 license )

Project Upgrade to V13 SP1

<= V13-Project

System functions

Project-Upgrade and Compatibility-Mode

Page 49 March 2017

V14 Project

Page 50: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

V14 Project

V14

V14 Engineering Software

V14 SP1 Project

V14 SP1

System functions

Online-Compatibility

Page 50 March 2017

No Online/Offline difference

No download or STOP necessary for:

Go Online

Monitoring blocks

Control variables

SW-Download in RUN (HW-Download always in STOP)

PLC-Upgrade from V14 to V14 SP1

Online access after upgrade of project

Customer benefits

No machine interruption by project upgrade

Program corrections can be downloaded in RUN

No lost of actual value

Upload in ES Download in PLC Online & Diagnosis Monitoring

Project Upgrade

Online Upgrade via

download in RUN

New

Page 51: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

System functions

Basic Integrity Check

TIA-Portal features a base-protective

mechanism to detect changes in custom project

file (e.g. blocks, hardware configuration).

Causes for changes for example can be

tampering outside the TIA-Portal or defects in

the data storage medium.

The TIA-Portal automatically extends integrity

information to the project file during save

operation

The check can be performed individually when

opening a project or generally during project

open (Global Setting)

Function

March 2017 Page 51

Improved detection of modifications on TIA-

Portal project files.

Customer benefits TIA-Portal

Project

File

Ad

din

g i

nte

gri

ty

info

rma

tio

n

Op

tio

na

l c

he

ck

of

inte

gri

ty i

nfo

rma

tio

n

TIA-Portal

Save project

Open project

1

2

1

2

Note: If basic integrity check is activated operating speed is reduced

when opening projects and especially in multi-user scenarios

Page 52: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

March 2017

System functions

Collection of useful function expansions

page 52

Write protection for program blocks

Password based write protection –

code visible but not editable

Also for failsafe block

(F signature is not changed)

Blocks still can be compiled

New properties and improved

usability in the alarm display

Receive alarms can be activated

within inspector window

With “freeze alarms” the view of the

alarm display can be frozen

New

New New

Page 53: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA updater: Fast mass update

Openness: Ex/Import HW +IO via AutomationML

ProDiag: Criteria analysis for S7-Graph

Safety: Consistent Hardware- and Software Upload

Option handling with S7-1500F

F-IO-Status function block

6. TIA Portal options 2. STEP 7 - Innovations

Freely editable comments for array and UDT

New instructions

Single block comparison

User comments visible directly in the code

New technology object for SIMATIC Ident

3. WinCC - Innovations Windows 10 support

Password API

User-defined filters for cross-references

Library handling

5. System functions

1. Hardware configuration

Support for new hardware components

- CPU1511T(F) / CPU1515T(F)

- Power Supply 60W 24/48/60V DC HF

New functions for the operability

TIA Portal

Highlights of TIA Portal V14 SP1

March 2017 Page 53

Details

Optimized and extended

commissioning wizard

Online/offline comparison of parameter

values

4. Startdrive - Innovations

Integration of SINUMERIK Operate in Runtime Advanced

OPC UA DA client for WinCC Runtime Professional

WinCC WebUX- Auto Login for WinCC RT Professional

Page 54: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Function

Multi-selection of support packages

Automatic download and installation of

several support packages

TIA Portal options

TIA Software Updater

Quick and easy adding of support

packages

Customer benefits

New New

TIA Software Updater

March 2017 Page 54

Page 55: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Replacement of hardware configuration and icons via XML files

Bidirectional workflow CAD systems TIA Portal

Free tool support thanks to a standardized interface

Further use case, e.g. TIA Selection Tool connection

HWCN + IO

Exp

ort

/im

po

rt

PLC_1

XML file PLC_2

XML file

IO-

Device_1

AML file

Exp

ort

/im

po

rt

TIA Portal V14 SP1 Electrical CAD tools

Customer benefits

TIA Portal options

Openness: Standardized exchange between Electro-CAD and automation

Article number

Article description

Network connections

Configured firmware version

Tag table

New

March 2017 Page 55

Page 56: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Project for Machine B

Project for Machine A

TIA Portal options

Openness: Automatic generation of projects, software and hardware

Project generator

DLL

TIA openness TIA Portal

Customer benefits

Generation of the

complete automation

project with TIA Portal

openness (hardware &

software)

Perfect customer workflow

from ordering to the

finished automated TIA

project.

March 2017 Page 56

Page 57: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Why?

Original

problem

Switchover of the view to the original

state when an error has occurred.

Function

TIA Portal options

ProDiag: Criteria analysis in the HMI PLC Code Viewer

Customer benefits

Focusing on the erroneous operands

March 2017 Page 57

Page 58: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA Portal Optionen

STEP7 Safety: Consistent Upload of Safety projects

K

R

E

I

S

CPU 1 ET200SP 1

CPU 3 ET200SP 3

CPU 2 ET200SP 2

Pro

ject

1

Pro

ject

2

Pro

ject

3

Service Techniker

Upload consistent

Avoidance of faults and

reduction of the service effort by

reduction of complex “offline”

administration

Time and cost savings

For S7-1500F and also

PLCSim Advanced

Customer benefits

Page 58 March 2017

Page 59: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA Portal Optionen

STEP7 Safety: Configuration Control for F-I/O

K

R

E

I

S

F-modularization and fast

customization on customer wishes

without ES for serial production of

machines

Supported for F-Periphery

dezentralized for F-PLC S7-

300/400/1200/1500 und centralized

for F-CPU S7-1500

Controlling via F-Periphery-DB-

Variable „DISABLE“

Analysis of the F-BG-deactivation

via „DISABLED“ F-DB-Variable

Customer benefits

from Safety-System-Version V2.1

Page 59 March 2017 3/31/2017 Page 59

CP

U 1

Master-Project

CP

U 1

Option 1

CP

U 1

Option 2

Page 60: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

TIA Portal Optionen

STEP7 Safety: F-IO-Status function block

K

R

E

I

S

Collective information of channel- or F-I/O

faults for each failsafe Runtime Group

„QSTATUS“ Bit (QBAD + Value_Status)

Separate collection of the RIOforFA-

Value-Status for all F-IO modules

Extensions for further F-I/O information

planned (PASS_OUT, ACK_REQ,

IPAR_OK, …)

Customer benefits

New

March 2017 Page 60

Page 61: TIA Portal V14 SP1 Technical slides - Lindh Automationmedia.lindhautomation.com/2017/05/TIA_Portal_V14_SP1_en-1.pdf · Unrestricted © Siemens AG 2017 TIA updater: Fast mass update

Unrestricted © Siemens AG 2017

Thank you for your attention.

Page 61

Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may

not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested

performance features are binding only when they are expressly agreed upon in the concluded contract.

All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties.

Their unauthorized use may infringe the rights of the respective owner.

siemens.com/tia-portal

March 2017