Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
ionscience.com
Unrivalled Gas Detection.
TIGER SELECTHANDHELD BENZENE DETECTOR
RAPIDLY DETECTS BENZENE & TOTAL AROMATIC COMPOUNDS (TACS).
Unrivalled Gas Detection. ionscience.com
Best available photoionisation (PID) detection•PIDindependentlyverifiedas
bestperformingonthemarket•Unrivalledsensitivitydetects
downtoppblevels•Selectivelydetects
benzenewithIonSciencebenzenepre-filtertube
•Continuousreadingsshownasmaxlevelreached
•In-builthumidityresistancewithnoneedtocompensate
•Anti-contaminationdesignforextendedfieldoperation
Minimise downtime•Readytouseinstantlywith
nocomplicatedsetup•Largebatterycapacity
givesseveraldaysofuse•Fastchargecapabilitygets
youupandrunningquickly•Simplemenurequires
nousertraining•Fastestdatadownloadvia
trueUSBconnection•Easilyupgradeyourinstrument
viatheweb24/7
Ease of use•Selfexplanatorysoftware
andcalibrationroutine•Easychangesensor,
electrodestackandlamps•Largeuserfriendlykeypad•Simple,one-handedoperation
Low cost operation•Inexpensiveconsumables
andparts•5yearwarrantywhen
instrumentregisteredonlinez
RAPIDLY DETECTS BENZENE AND TOTAL AROMATIC COMPOUNDS (TACS) PROVIDING THE MOST ACCURATE, RELIABLE DATA AVAILABLE. RELIABLE DATA AVAILABLE
Unrivalled Gas Detection. ionscience.com
Arevolutionaryhand-helddetector,TigerSelectcanbeoperatedeitherwithabenzenepre-filtertubetodetectbenzeneselectively,orwithouttodetecttotalaromaticcompounds(TAC).Forsimplicityandeaseofuse,theTigerSelecthasbeensplitintotwo,user-friendlymodes:BasicandAdvanced.Bothmodesareuser-selectable.
UtilisingthehighoutputIonScience10.0eVlampconfiguration,areadingfortotalaromaticcompounds(TACs)isseenimmediatelyonstart-up.Shouldaromaticsbedetected,anIonSciencebenzenepre-filtertubecanbeeasilyattachedtoensurerapiddetectionandselectivemeasurementofbenzene.TigerSelectcanalsoprovide15minuteshorttermexposurelimits(STELs)and8hourtimeweightedaverages(TWAs)forTACs.
Throughoutthemeasurementprocess,TigerSelectcontinuestodisplayrealtimedata,ensuringthefinalreadingrepresentsthefullvalueofactualbenzenepresent.Benzeneconcentrationsaredisplayeddowntoppblevels,givingyouthemostaccurate,reliabledatayoucancounton.
Inaddition,theuniqueMiniPID2sensorincorporatesbothanti-contaminationtechnologyandFenceElectrodetechnologyforextendedoperationindifficultworkingenvironments.
TigerSelectcanalsobeusedinstandardoperationalmodewithouttheuseofabenzenepre-filtertubetodeliveractiveindicationsofvolatileorganiccompounds(VOCs),includingbenzeneatconcentrationsaslowas1ppbbenzeneequivalent.
Additionally,TigerSelectmaybeusedalongsidetheCubTACpersonalPIDmonitortoprovidetheultimatesolutionforbenzenedetection.Visitwww.ionscience/cubformoredetails.
Applications•Confinedspaceentrypre-
screeningduringrefineryandplantmaintenancescreeningduringrefineryandplantmaintenance
•Marinespillresponse•Refinerydown-stream
monitoring•Hazardousmaterialresponse•TotalAromaticCompounds
(TAC)detectionatloadingdocksandbargeoperations
Accessories TigerSelectisavailablewithanexclusiverangeofaccessories.Visitwww.ionscience.com/selectorcontactIonScienceformoreinformation.
Unrivalled Gas Detection. ionscience.com
Technical
Manufactured by:
Minimum resolution•Standardmode(PPM)0.1ppm
•Tubemode0.001ppm
Maximum reading•Standardmode20,000ppmor
20,000mg/m3(gasdependent)
•Tubemode200ppmor
639mg/m3benzene
Response time•120seconds.Progressive
indicationofbenzene
breakthroughisdisplayedin
•realtime
Accuracy•10%displayreading
onedigitbenzene
Linearity•5%displayreadingonedigit
Intrinsically safe approvals•II1GExiaIICT4Ga
•Tamb=-15oC≤Ta≤+45oC
(withlithiumionbatterypack)
•Tamb=-15oC≤Ta≤+45oC
(withalkalinebatterypack)
•ITS09ATEX26890X
IECExITS10.0036X
•3193491conformstoUL
Std.913,61010-1&
•CertifiedtoCAN/CSA
Std.C22.2No.61010-1
Battery life•Li-ion:lifeupto24hours,
chargetime6.5hours
•Alkaline:3xAA,typically
8.5hourslife
Lamps•10.0eVKryptonPIDlamp
Data logging•>120,000datalogpoints
includingdateandtimestamp
Communication•DirectUSB1.1
Calibration•2and3pointcalibration(via
calibrationkitaccessory)
Alarm•FlashingLED’sAmber(low
alarm)Red(highalarm)
•Sounder95dBAat300mm
(12”)Vibrationonalarm
•Pre-programmedTWAandSTEL
Flow rate•≥220ml/min
Temperature•Operating:-20to60oC,-4to
140oF(nonIntrinsicallySafe)
•Humidity:0-99%RH
(noncondensing)
Protection•DesignedtoIP65(heavyrain)
•1180
•EMCtestedtoEN61326-
1:2006,EN50270:2006&
CFR47:2008ClassA
Weight & dimensions•Instrument(probefitted,
notubeattached)
•Height:465xWidth:89xDepth:
61mm(18.3x3.5x2.4”)
•Instrumentweight:0.75kg
•Standardcase
•Packedweight:5kg(176oz)
ION Science LtdThe Hive, Butts Lane, Fowlmere, Cambridgeshire, SG8 7SL, UK
T +44 (0)1763 208503E [email protected]
Unrivalled Gas Detection. ionscience.com
SelectV1.7.Thispublicationisnotintendedtoformthebasisofacontractandspecificationscanchangewithoutnotice.
Note:FenceElectrodeTechnologyisproducedbyIonScienceLtd,andprotectedbyU.S.PatentNo.7,046,012.EP1474681,otherpatentspending.
“WeneededaninstrumenttodetectthelevelsofVOCand
benzenewhenweopenourpipingsystem.Ourcentralregionin
Canadahasbeenusingtheproductforayearorsonowsowe
wereconfidentthattheinstrumentwasrightforuscomparedto
theDraegerCMSchipdetectorswhichwehadusedinthepast.”
Bruce Sangster, Enbridge Pipelines