Upload
trinhthuan
View
226
Download
0
Embed Size (px)
Citation preview
1 32 4 5
NEWPROG
6 7
C1
1 32 4 5
NEWPROG
6 7
C11 32 4 5
NEWPROG
6 7
C1
b
TIME/DATE SU WISET
SET SU WI SET
DAY
WI
WISET
DAY
WI SET WI
MONTH
SET WI
MONTH
SET WI
YEAR
SET SU WISET SU WI
SET SU WI
SET
DAY
SU SET
DAY
SU SET SU
MONTH
SET SU
MONTH
SET SU
YEAR
SU
SET SUmmer WInter-time
TIME/DATE SU WISETTIME/DATE SU WI
PROGMODE
SET
TIME/DATE SU WISET
SET TIME/DATE
aTIME/DATE SU WI
PROGMODE
SET TIME/DATE SU WISET TIMESET TIMESET TIMESET TIMESET
1 32 4 5
NEW
ON
OFF
PROG
C1
6 7 1 32 4 5
NEW
ON
OFF
PROG
C1
6 7
TESTMODIFYNEWPROG
C1
TESTMODIFYNEWPROG
C 2
C1
C2
TESTMODIFYNEWPROG
C1
NEWPROG
C1
TESTMODIFYNEWPROGMODE
SETTIME/DATE SU WIPROGMODE
SET
C1 C2
DAY1 - 7 1 - 5 6 - 7 1 32 4 5
ON
OFF6 7 1 32 4 5
ON
OFF6 7 1 32 4 5
ON
OFF6 7
5x
ANY DAY
Select switch-on day 2
NEWPROG
C1
1 32 4 5
NEW
ON
OFF
PROG
C1
6 7
1 32 4 5ON
OFF6 7 1 32 4 5
ON
OFF6 7
Select switch-off day 2 TESTMODIFYNEWPROG
C1
SET
DAY
DATE SET DATE
DAY
SET DATE
MONTH
SET DATE
MONTH
SET DATE
YEAR
SET DATE
YEAR
TIME/DATE SU WISET
Prog NEW
1 32 4 5
NEWPROG
6 7
C1
NT
2927
23/0
0
ProgrammingOne program = switch-on time + switch-off time + switch-on and switch-off days Programs with predefined switch-on / switch-off days • DAY 1-7 (MO-SU) • DAY 1-5 (MO-FR) • DAY 6-7 (SA and SU) Programs for each channel are interlinked with OR logic.
MicroRex D21/D22 Plus2
6 037 70 / 71
Time switch
LN
L N
LN
MENU OK
+
1L
2N
MENU OK
+
1200 W
60 VA
2300 VA
60 W 7µF
+
c
R
1800 W
+
1800 W
2300 W
+
3680 W
! Safety notes
This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installation, read the operating instructions and observe the product-specific requirements for the installation location. Use only original spare parts for repair and maintenance. All Legrand products may be opened and repaired only by specially trained Legrand personnel. Unauthorised opening and repair by other persons will invalidate all claims for liability, replacement or warranty services. The device contains a Li cell type battery (Li) CR2032. When the product reaches the end of its life, this cell must be correctly removed and disposed of in accordance with national legislation and the requirements of environmental protection.
The device should not be used on isolated low voltage.
Operating principle:
Typ 1.B. S. T. IEC/EN 60730-1, IEC/EN 60730-2-7 Operation in a normal environment Montage: in distribution panel, Degree of contamination: 2 Switch output, potential-free
Programs: 28 14 / channel
Ganggenauigkeit ± 1 s / day under typical installation conditions
230V 50/60Hz
1x 16A/250V~µ cos ϕ = 1 2x 16A/250V~µ cos ϕ = 1
0,9 W 1,3 W
M
1 ... 4 mm2 0,5 ... 2,5 mm2
230V 50/60Hz
6 037 70 6 037 71
Power consumption
Battery reserve: 3 years
+-
+-
- 20 °C … +55 °C
- 20 °C … +60 °C
C1
C2
Confirm menu selection or adopt parameters
• Select menu items or set parameters.• Channel selection
Menu selection, back in menu, actuation > 1s = back to status display
IP 20
MODIFYPROG
C1
Reset
Note!A reset clears the entire memory, which means that all previously set data will be lost. Press and hold all four keys together for about 2 seconds, then release them. The time, date, summertime/wintertime and switching times will have to be re-entered.
1 32 4 5
TIME
C1 OFF
6 7
WI
NEXT
AUTO
TIME/DATE SU WIPROGMODE
SETTESTMODIFYNEWPROG
MODE
SET
TESTMODIFYNEWPROG
C1
TESTMODIFYNEWPROG
C 2
C1
C2
MODIFYPROG
C1
MODIFYPROG
C1
1 32 4 5
MODIFY
ON
OFF
PROG
C1
6 7
1 32 4 5
MODIFY
ON
OFF
PROG
C1
6 71 32 4 5
MODIFY
ON
OFF
PROG
C1
6 7 1 32 4 5
MODIFY
ON
OFF
PROG
C1
6 7
TESTMODIFYNEWPROG
C1
TESTMODIFYNEWPROG
C1
d
C1 C2
• • •
Edit program
Change switching times
Change switching days
MODIFYPROG
C1
Prog 1 Prog 2 Prog 3
• • • •
NEWPROG
C1
1 32 4 5
MODIFY
ON
OFF
PROG
C1
6 7
1 32 4 5ON
OFF6 7 1 32 4 5
ON
OFF6 7
1 32 4 5ON
OFF6 7 1 32 4 5
ON
OFF6 7
1 32 4 5ON
OFF6 7
5x
DEL ONE -> Delete a single program, DEL C1/2 -> Delete the programs for a channel
TESTMODIFYNEWPROG
C1
MODIFYPROG
C1
MODIFYPROG
C1
MODIFYPROG
C1
1 32 4 5
MODIFY
ON
OFF
PROG
C1
6 7
MODIFYPROG
MODIFYPROG
C1
MODIFYPROG
Prog 2
• • •
MODIFYPROG
C1
Prog 3
• • •
e
TESTMODIFYNEWPROG
C1
TESTPROG
C1
PROG
C1
TEST
TESTPROG
C1
1 32 4 5
TEST
ON
OFF
PROG
C1
6 7 1 32 4 5
TEST
ON
OFF
PROG
C1
6 7
1 32 4 5
TEST
ON
OFF
PROG
C1
6 7
TESTPROG
• • •
• • •
PROG
C1
TEST
• • •
Prog 1 Prog 2
DAY 1 DAY 2
prog -> Programs in the order entered SERIAL -> Switching commands in chronological order
Mode PERManent Continuous switching On/Offf
C1AUTO
C 2
PERMMODEC1
C2
EXTRA
AUTO PERMMODE EXTRA
TIME/DATE SU WIPROGMODE
SET
AUTO EXTRAPERMPROGMODE
SET
AUTO EXTRAPERMMODEC1
AUTO EXTRAPERMMODEC1
1 32 4 5
TIME
C1 ON
6 7
PERM
SUPERM
1 32 4 5
TIME
C1 OFF
6 7
PERM
SUPERM
PERMMODEC1
PERMMODEC1
C1 C2
Mode EXTRAg
C1AUTO
C 2
PERMMODEC1
C2
EXTRA
AUTO PERMMODE EXTRA
1 32 4 5ON
TIME
C1 OFF
6 7
EXTRA
SU
NEXT
EXTRATIME/DATE SU WI
PROGMODE
SET
AUTO EXTRAPERMPROGMODE
SET
AUTO EXTRAPERMMODEC1
AUTO EXTRAPERMMODEC1
C1 C2
State of contact set by program will be reversed. The next program automatically returns the switch to ON or OFF as programmed.
MODIFYPROG
Prog MODIFY Prog MODIFY
+
Switch off the device before dismantling the module. Do not switch on again until the module has been installed. Always use a Li cell type battery (Li) CR2032, 3V. High temperature type min +70°C.
Prog TEST