28
Tips and Tricks Eland Afuang Client Service Manager Water Network and Operational Systems Modelling User Group 5 th August 2014 SA Water Learning Centre, Adelaide SA

Tips and Tricks - Innovyzeblog.innovyze.com/wp-content/uploads/2014/09/1230-Tips-and-Tricks...Tips and Tricks Eland Afuang Client Service Manager Water Network and Operational Systems

Embed Size (px)

Citation preview

Tips and Tricks

Eland Afuang Client Service Manager

Water Network and Operational Systems Modelling User Group

5th August 2014 SA Water Learning Centre, Adelaide SA

Overview

Pressure Reducing Valves

Variable Speed Pumps

Transients / Surge

Overview

Pressure Reducing Valves

Variable Speed Pumps

Transients / Surge

Pressure Reducing Valves

Fixed outlet

Fixed ratio

Pressure Modulated

Electronic (Remote Controlled)

Hydraulic (Flow Modulated)

Fixed Outlet PRV

With pilot valve that allows a fixed outlet

pressure downstream

Fixed Ratio PRV

Reduced pressure by a set amount

Value between 0 to 1

Pressure Modulated PRV

Electronic (Remote Controlled) using solenoid

Maintain pressure at CP (Critical Point)

Pressure Modulated PRV

Hydraulic (with local flow modulation)

via an orifice plate / venturi tube

Flow Modulated Valve (FMV)

Model Instabilities in PRVs

Model Instabilities in PRVs

In some cases, there is a sudden

increase/decrease of demand due to the

demand profile

May need to review and ‘smooth’ the

demand profile if possible

Model Instabilities in PRVs

Manifold (parallel PRVs)

e.g. Night & day time valve

May need to add UPC (Rule based controls in

InfoWater / H2OMap) to represent switching

Combine two PRVs into one and use control grid

Valves in InfoWorks WS are physical objects

which respond to hydraulics

Overview

Pressure Reducing Valves

Variable Speed Pumps

Transients / Surge

Variable Speed Pumps

Pump Curve

Variable Speed Pumps

Pump Station Properties > Pump Data tab

Variable Speed Pumps

AUTO or PROFILE mode

Pump Station Properties > Pump Control Data tab

Variable Speed Pumps

PS property sheet > Pump Data > PST Operation

Variable Speed Pumps

Can be modelled via UPC

PST operates on ZERO FLOW – Head too high

Demand is low and min speed too high

Check pump nominal speed (oftentimes used as min speed)

Decrease min speed

Variable Speed Pumps

Implicit Variable Speed Pump Control

Affinity Laws

Variable Speed Pumps

Applies to Standard and Fire Flow runs only

Rule based controls cannot be used

Pump can’t deliver head (run message)

When updating with latest version

Make sure to set a min speed

Overview

Pressure Reducing Valves

Variable Speed Pumps

Transients / Surge

Transients / Surge

Transients Advisor

Estimating potential hydraulic transients based

on velocity change (Joukowski's law)

Maximum Transient Pressure

Transients / Surge

Transients / Surge

Transients / Surge

Detailed analysis

Transients / Surge

Detailed analysis

WANT MORE TIPS?

Want more tips?

Blog: http://blog.innovyze.com/

Forum: http://forums.innovyze.com

Support: [email protected]

QUESTIONS? Thank You