1
SummaryThe following is a relative safety assessment survey campus wide for Tyler Junior College. This is a surveywhich does not recommend an absolute safe room or storm shelter, but enables the college to perform duediligence and complete a best practices assessment of the “relative safer place” to go in a storm event. Thereare no storm shelters on campus that meet the "Standard for Design and Construction of Storm Shelters -2008". The contents of this report are not recommendations for absolute safety in a storm event, but arerecommendations which, following industry standards and best practices, would be the relatively safer placesto shelter in the event of extreme weather. The professional opinion of this survey is that providing arecommendation for a relative safer place, based on available information, is better than the absence of arecommendation or plan in the case of a storm event. These recommendations are made in order to promotethe health, safety and welfare of the occupants. Our assessments are based on general structuralobservations and the following recommended areas should not be construed as storm shelters or safe roomsbut as areas that may be somewhat safer than other areas.
The following is a description of our findings.
Administrative and Service Buildings, West Campus, and Lindale Campus
2
WEST CAMPUS
ROBERTSON RD. 46
48
47
1530 S. SW Loop 323 • Tyler, TX 75701
MAIN CAMPUS MAP
RESIDENCE HALLS
TJC is one of the largest community colleges in Texas, with almost 600 faculty members, approximately 11,500 students enrolled per semester, and 1,011 May graduates.
ACADEMICS, ADMINISTRATION & SERVICES
ATHLETIC FACILITIES8. Bateman Hall3. Claridge Hall2. Crossroads Hall18. Holley Hall10. Hudnall Hall40. Louise H. & Joseph Z.
Ornelas Residential Complex
4. Sledge Hall19. Vaughn Hall14. Wesley House
38. Apache Belle Studio 16a. Apache Rooms13. Baldwin Facilities & Construction
(BMB)36. Band Hall11. Campus Safety (CS)12. Campus Safety Annex6. Campus Services (PRCH)29. Fine Arts (FA)22. Genecov Science Buildings(G)(G2)(GB)25. Jenkins Hall (J) 27. Pirtle Technology (T)23. Potter Hall (P)5. Research & Marketing Services (RMS)
7. Residential Life & Housing (RLH)1. Robert M. Rogers Nursing &
Health Sciences Center (RNHS)1a. Dental Hygiene Clinic 16. Rogers Student Center (RSC)16c.Campus Safety Substation 41. Satellite Physical Plant17. Vaughn Conservatory (VC) 21. Vaughn Library (LRC)9. Dual Credit/Early College Office
(DCB)20. White Administrative Services
Center (WASC) 32. Wise Cultural Arts (WCA)
43. Athletic Field House (FH)42. Athletic Strength & Conditioning Facility34. Intramural Field33. JoAnn Medlock Murphy Tennis Center (JMTC) 26. Louise Brookshire Community Tennis
Complex37. Ornelas Health & Physical Education
Center (OHPE) 44. Pat Hartley Complex & Concession
Stand45. Pat Hartley Field35. Wagstaff Gymnasium (WG)
06/30/17
ATTRACTIONS
DINING
WEST CAMPUS
24. Gatewood Garden31. Ina Brundrett Azalea
Garden32a. Jean Browne Theatre (JBT)28. The Center for Earth &
Space Science Education39. Tyler Museum of Art30. Wise Auditorium (WA)
16b. Apache Junction Cafeteria2a. Chick-Fil-A21a. Starbucks27a. Subway
46. Energy Center (ECB)47. Skills Training Center (STC)48. Regional Training and
Development Center (RTDC)
6
8
20
13
14
5
17
21
16
24 25
31
3029
3218
11
19
45
44
43
41
42
403326
27
28
22
23
34
35
1
2
12
3638
37
39
9
7
10
4
3
Design by Michael Karpovage of mapformation.com, June, 2016
1400 East Fifth Street - Tyler, TX 75798Toll Free: 1 (800) 687-5680 Local: 903-510-2200www.TJC.edu
Table of ContentsSummary 1Table of Contents 2Administrative and Service Buildings, West Campus and Lindale Campus (see bldg numbers on map below for reference) Residential Life and Housing (7) 3 Campus Services (6) 4 Campus Safety (11) 5 Baldwin Facilities and Construction (13) 6 White Administrative Services Center (20) 7 Satellite Physical Plant (41) 10 Campus Safety Annex (12) 11 Dual Credit / Early College Office (9) 12 Research and Marketing Services (5) 13 TJC Energy Center (46) 14 Skills Training Center (47) 15 Regional Training and Development Center (48) 17 Vet Tech - Lindale (not on map) 18
3
48 sq ft 48 sq ft
72 sq ft
RR
N
Residential Life and Housing
RELATIVE SAFER AREA:Restrooms
OCCUPANT ESTIMATE:33 total occupants located inrelatively safer areas (using5 SF per occupant)
LEVELS: Two LevelsCONSTRUCTION: Unknown
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
FIRST LEVELNOTES (5 SF per occupant): - Restrooms = 96 SF = 19 occupants
BASEMENT LEVELNOTES (5 SF per occupant): - Restroom = 72 SF = 14 occupants
4
190.56 sq ft
N
Campus Services
RELATIVE SAFER AREA:Basement corridor
OCCUPANT ESTIMATE:38 total occupants located inrelatively safer areas (using5 SF per occupant)
LEVELS: Two LevelsCONSTRUCTION: Unknown
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Restrooms = 190 SF = 38 occupants
FIRST LEVEL BASEMENT LEVEL
5
48 sq ft
N
Campus Safety
RELATIVE SAFER AREA:Rear corridor
OCCUPANT ESTIMATE:9 total occupants located inrelatively safer areas (using5 SF per occupant)
LEVELS: One LevelCONSTRUCTION: Appears to be stick-framed wood construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Corridor = 48 SF = 9 occupants
6
391 sq ft
BREAK
N
Baldwin Facilities and Construction
RELATIVE SAFER AREA:Break room
OCCUPANT ESTIMATE:78 total occupants locatedin relatively safer areas(using 5 SF per occupant)
LEVELS: One LevelCONSTRUCTION: Pre-Engineered Metal Building
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Break Room = 391 SF = 78 occupants
7
162 sq ft
301.5 sq ft
301.5 sq ft
250.94 sq ft
25.33 sq ft
25.33 sq ft
2,187.04 sq ft
204 sq ft
191.92 sq ft
216.42 sq ft
N
White Administrative Services Center
RELATIVE SAFER AREA:Stairs, elevator lobby,restrooms. IT break area forstaff already occupying thespace.
OCCUPANT ESTIMATE:273 total occupants locatedin relatively safer areas(using 5 SF per occupant)LEVELS: Three Levels
CONSTRUCTION: Appears to be conventional steel construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - West Stair = 216 SF = 43 occupants - Central Stair = 191 SF = 38 occupants - Elevator Lobby = 162 SF = 32 occupants - Central Restrooms = 603 SF = 120 occupants - IT Break Area = 204 SF = 40 occupants
FIRST LEVEL
8
162 sq ft
189.5 sq ft189.5 sq ft
395 sq ft
191.92 sq ft216.42 sq ft
N
White Administrative Services Center
RELATIVE SAFER AREA:Stairs, elevator lobby,restrooms, conference room
OCCUPANT ESTIMATE:267 total occupants locatedin relatively safer areas(using 5 SF per occupant)LEVELS: Three Levels
CONSTRUCTION: Appears to be conventional steel construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - West Stair = 216 SF = 43 occupants - Central Stair = 191 SF = 38 occupants - Elevator Lobby = 162 SF = 32 occupants - Central Restrooms = 379 SF = 75 occupants - Conference Room = 395 SF = 79 occupants
SECOND LEVEL
9
162 sq ft
216.42 sq ft
191.92 sq ft
148.5 sq ft 148.5 sq ft
170 sq ft
N
White Administrative Services Center
RELATIVE SAFER AREA:Stairs, elevator lobby,restrooms
OCCUPANT ESTIMATE:206 total occupants locatedin relatively safer areas(using 5 SF per occupant)LEVELS: Three Levels
CONSTRUCTION: Appears to be conventional steel construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - West Stair = 216 SF = 43 occupants - Central Stair = 191 SF = 38 occupants - Elevator Lobby = 162 SF = 32 occupants - Northwest Restrooms / Alcove = 467 SF = 93 occupants
THIRD LEVEL
10
56 sq ft
N
Satellite Physical Plant
RELATIVE SAFER AREA:Restroom
OCCUPANT ESTIMATE:11 total occupants locatedin relatively safer areas(using 5 SF per occupant)LEVELS: One Level
CONSTRUCTION: Unknown
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Restroom = 56 SF = 11 occupants
11
Campus Safety Annex
RELATIVE SAFER AREA:Central patrol squad room(shown in picture below)
OCCUPANT ESTIMATE:28 total occupants locatedin relatively safer areas(using 5 SF per occupant)LEVELS: One Level
CONSTRUCTION: Appears to be stick-framed wood construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Central patrol squad room = 144 SF = 28 occupants
PLANUNAVAILABLE
CENTRAL PATROLSQUAD ROOM
12
Dual Credit / Early College Office
RELATIVE SAFER AREA:Print room, corridor, newrestroom (all shown inpictures below)
OCCUPANT ESTIMATE:37 total occupants locatedin relatively safer areas(using 5 SF per occupant)LEVELS: One Level
CONSTRUCTION: Unknown
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Print room = 45 SF = 9 occupants - Corridor = 84 SF = 16 occupants - New restroom = 60 SF = 12 occupants
PLAN UNAVAILABLE
PRINT ROOM CORRIDOR NEW RESTROOM
13
Research and Marketing Services
Basement nook, secondfloor corridor, bottom ofstair (all shown in picturesbelow)
OCCUPANT ESTIMATE:54 total occupants locatedin relatively safer areas(using 5 SF per occupant)
LEVELS: Three LevelsCONSTRUCTION: Unknown
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - Basement nook = 56 SF = 11 occupants - Second floor corridor = 180 SF = 36 occupants - Bottom of stair = 36 SF = 7 occupants
RELATIVE SAFER AREA:
PLAN UNAVAILABLE
BASEMENT NOOK 2ND FLOOR CORRIDOR BOTTOM OF STAIR
14
©
5201 S. Broadway, Suite 200Tyler, TX 75703903.592.0728
903.595.0369 [email protected]
12/20/13JOB NUMBER
SHEET NUMBER
12.058DATE
REVISION HISTORY
1ST FLOOR PLAN
E
D
C
B
A
1 2 3 4 5 6
A101
TYLE
R J
UN
IOR
CO
LLEG
EE
NE
RG
Y C
EN
TER
TYLE
R, T
X
PROJECT ARCHITECT
3 3 59
REG
IS
TER ED ARCHITECT
ST
AT E O F T EXA
S
T
IT
PA
I Z
V
A E
TEEN
SJ M
CK
S
F
R
BRANDY ZIEGLER, AIA
124B124A
KY
124D124C
103B103A
111C
E D CF
PM N111B 113
G
110C
YA 110
YA
100A
100B
LL
102
XX
A1A104
A1A105
A5A603
E1A606
D5A610
A5A604
A3A604
C2A501
A1A502
A2A501
C1A502
A6A503
A4A503
E4A702
E1A701
E1A702
C4A701
C1A701
D4A701
D1A701
E4A701
A4A701
A1A701
B1A701
B4A701
A1A503
A2A503
RAMP UP
DISPLAY CASE
TOOL CHECKOUT COUNTER
DISPLAY CASE
6" MTL STUD WALLW/ 2" INSULATEDPANEL
HANDRAILRE: SIM AS103ALL OCCURANCES
OUTSIDE STORAGE / RECEIVING
RAISEDLOADING
DOCK
LABHVAC
111
LABHVAC
114
LABHVAC
115
LABHVAC
116LABCOMPUTER
117
LABORATORYSHARED
102
ROOMREST
106
ROOMREST
105
HSKG107
ELEV MECHELEC/
108
ELECTRICAL113
AH WORK RMHVAC
112B
LOBBY101
SPACESTUDY
104
CORRIDOR110
STAIRS 1ST1
STAIRS 2ST2
VESTIBULE100
CORRIDOR127
VESTIBULE124
UNIT WORK RMHVAC
112A
ELEVATORFREIGHT
126
C5A609
#DrgID#LayID
A1A608
111A
111D
114B
114A
115B
115A
116
120
121
122
123
119
125
107
103C
101
110B117
105
106
108
118
A
A11
2B
BB
AA
112A
BB
114C
AA
AA
115C
115D
F J
J
H
H
K
K
M
M
A
A
D
D
1515
1212
1010
99
77
66
44
33
22
B
1616
1313
11
88
L
L
G
G
C
E
55
1111
1414
N
N
P
PF
8'-0
"5'
-0"
12'-1
1"6'
-7"
5'-6
"6'
-0"
4'-0
"10
'-0"
15'-0
"23
'-10"
7'-1
"8'
-6"
15'-7
"1'
-2"
12'-1
0"
5'-10" 1'-2" 11'-6" 2'-7" 6'-8" 9'-3" 20'-0" 10'-0" 12'-6" 13'-0" 16'-0" 18'-6" 13'-0" 3'-01/4"
131'
-4"
5'-0
"62
'-4"
25'-5
"29
'-7"
14'-0
"
3'-1" 3'-11" 85'-6" 51'-81/4"
6'-1
0"1'
-2"
5'-0
"12
'-11"
6'-7
"5'
-6"
6'-0
"4'
-0"
10'-0
"15
'-0"
23'-1
0"7'
-1"
8'-6
"15
'-7"
14'-0
"1'
-2"
12'-1
0"
136'
-4"
144'-21/4"
144'-21/4"
2'-61/2" 34'-3" 2'-41/2" 18'-0" 9'-11" 77'-11/4"
8'-1
0"13
'-811
/64"
7'-1
37/6
4"5'
-8"
4'-1
01/4"
5'-8
"5'
-51/
2"5'
-9"
5'-3
1/2"
13'-8
"2'
-7"
6'-4
"2'
-8" 2"
9'-0
33/6
4"9'
-53/
4"11
'-03/
4"
54'-81/2" 5'-3" 16'-21/8" 7'-61/2"1'-97/8" 1'-83/8"
6'-4"1'-111/4"
5'-93/4"1'-1057/64"
6'-11"1'-77/8"
6'-925/64" 11'-239/64" 4'-4" 3'-27/8"
2'-61/2" 2'-71/2" 14'-6" 14'-6" 2'-71/2"2'-41/2"
2" 13'-8" 4" 3'-10"1'-111/4" 545/64"
4'-6"3'-01/16" 3'-107/8"
6'-3" 10'-107/64" 11'-6" 6'-6" 4'-03/4" 4" 7'-11/4" 1'-1133/64" 9'-3" 15'-447/64"
5'-7" 13'-51/2" 1'-3" 13'-51/2" 5'-5" 61/2" 13'-91/32" 3'-815/32"1'-111/4"
7'-113/4"
35'-6
"26
'-6"
14'-1
3/4"
11'-3
1/4"
4'-4
1/2"
1'-8
1/2"
5'-3
"5'
-21/
8"1'
-6"
5'-8
7/8"
4'-7
5/8"
1'-2
3/8"
14'-10" 5'-6" 1'-0" 8'-111/2" 15'-11/8" 6'-25/8" 11'-41/2" 10'-71/2" 12'-43/4" 24'-101/2" 14'-11/2" 11'-111/4"
1'-6
"6'
-07/
8"11
'-31/
4"1'
-27/
8"7'
-0"
9'-6
"11
'-0"
11'-0
"9'
-2"
19'-7
"9'
-55/
8"85/
8"10
'-81/
2"13
'-91/
4"
20'-1
"4'
-25/
8"8'
-23/
8"7'
-71/
2"19
'-11/
2"8'
-3"
28'-6
"26
'-6"
13'-6
"
3'-11" 4'-23/4" 10'-47/8" 1'-0" 14'-113/8" 10" 13'-31/4" 83/8"101/2"
4'-41/8"1'-05/8"
6'-01/4" 5'-35/8" 10'-11/2" 1'-15/8" 11'-91/8" 24'-101/2" 14'-11/2" 11'-111/4"
38'-0" 33/8" 19'-25/8" 11'-0" 12'-0" 12'-6" 24'-101/2" 14'-11" 11'-13/4"
38'-10" 18'-8" 1'-13/8" 2'-7" 3'-107/8" 2'-93/8" 6'-113/8" 8'-7" 9'-7" 1'-0" 8'-55/8" 41'-55/8"
A3A602
A3A602
A5A606
A4A607
D1A603
D2A610
A1A607
A1A609
A5A605
C1A601
C1A601
A3A605
A1A605
D1A604
CLASSROOM103
OFFICE119
OFFICE122
OFFICE123
STORAGETOOL
120
MECHELEV
118
WORK ROOM121
OFFICE125
ELEVATOR126
A1A601
A1A601
A3A609
C3A602
C3A602
SCALE:1/8" = 1'-0"A1 FIRST FLOOR PLAN0 4' 8' 16'
N
263.04 sq ft
264.42 sq ft
573.75 sq ft
©
5201 S. Broadway, Suite 200Tyler, TX 75703903.592.0728
903.595.0369 [email protected]
12/20/13JOB NUMBER
SHEET NUMBER
12.058DATE
REVISION HISTORY
2ND FLOOR PLAN
E
D
C
B
A
1 2 3 4 5 6
A102
TYLE
R J
UN
IOR
CO
LLEG
EE
NE
RG
Y C
EN
TER
TYLE
R, T
X
PROJECT ARCHITECT
3 3 59
REG
IS
TER ED ARCHITECT
ST
AT E O F T EXA
S
T
IT
PA
I Z
V
A E
TEEN
SJ M
CK
S
F
R
BRANDY ZIEGLER, AIA
XA
Z
XE
XG XHR XF
YB
W W
ZFZC
ZG
205B
XD
XB
XC
201A
219
213B
213A
214
217
216
207206
220
225 221222223224
205A
203
204
SU T R R
YB
218B
211210209208
201B
215
218A
Q
212
V
205C
A A A
DW
A1A106
A1A107
A5A603
E1A606
D5A610
A5A604
A3A604
C2A501
A1A502
A2A501
A6A503
A4A503
A1A503
A2A503
#DrgID#LayID
E4A703
E1A703
D4A703
D1A703
C1A703
C3A703
RAMP UP
DISPLAY CASE
HAND RAIL
OPENTO
BELOW
OPENTO
BELOW
OPENTO
BELOW
LABCOMPUTER
215
PLANT LABPOWER
212
PLANT LABPOWER
214
CLASSROOM201
STORAGE218
OFFICE209
OFFICE210
OFFICE211
ROOMWORK
220
TECHNOLOGY LABELECTRICAL
217
ROOMREST
204
PLANT LABPOWER
216
LOUNGEFACULTY
225
SPACESTUDY
202
CORRIDOR205
A1A608
ENCLOSED CATWALK
EXISTINGLIFT
F J
J
H
H
K
K
M
M
A
A
D
D
1515
1212
1010
99
77
66
44
33
22
B
1616
1313
11
88
L
L
G
G
C
E
55
1111
1414
N
N
P
PF
A3A602
A3A602
A5A606
A4A607
D1A603
D2A610
A1A607
A1A609
A5A605
C1A601
A3A605
A1A605
F
144'-41/2"
5'-10" 1'-2" 11'-6" 2'-7" 6'-8" 9'-3" 20'-0" 10'-0" 12'-6" 13'-0" 16'-0" 18'-6" 16'-21/2"
131'
-4"
8'-0
"3'
-10"
1'-2
"12
'-11"
6'-7
"5'
-6"
6'-0
"4'
-0"
10'-0
"15
'-0"
23'-1
0"7'
-1"
8'-6
"15
'-7"
14'-0
"14
'-0"
144'-41/2"
1'-2" 9'-3" 9'-3" 9'-3" 9'-3" 20'-0" 10'-0" 12'-6" 13'-0" 16'-0" 18'-6" 13'-0" 3'-21/2"
136'
-4"
8'-0
"5'
-0"
12'-1
1"6'
-7"
5'-6
"6'
-0"
4'-0
"10
'-0"
15'-0
"23
'-10"
7'-1
"8'
-6"
15'-7
"14
'-0"
1'-2
"12
'-10"
14'-0
"55
'-0"
62'-4
"
91/2"
19'-9
1/2"
9"19
'-9"
9"13
'-2"
7'-1
1"6'
-0"
25'-1
053/6
4"13
'-811
/64"
8'-1
0"
7'-0" 85'-6" 51'-101/2"
7'-0" 91/2" 13'-77/8" 40'-15/8" 5'-6" 25'-5" 14'-13/8" 5'-6" 6" 8'-1157/64" 4"2'-27/64"
6'-6" 5'-6" 8'-31/8"
17'-1
1"8'
-1"
6"3'
-5"
16'-9
"9'
-0"
16'-9
5/8"
1'-5
3/4"
6'-4
"1'
-1"
54'-1
15/8"
2'-61/2" 2'-71/2" 14'-6" 14'-6" 2'-71/2" 2'-41/2" 18'-0" 2'-5" 4'-6" 3'-0" 22'-33/8" 6'-3" 4'-55/8" 8'-31/8" 10'-117/8" 4'-3" 6" 5'-6"6" 1'-7"
3'-11" 2'-1" 6'-81/2"
2'-61/2" 34'-3" 2'-41/2" 18'-0" 1'-93/4" 5'-81/2" 2'-43/4" 77'-31/2"
5'-7" 13'-51/2" 1'-3" 13'-51/2" 5'-5" 13'-101/4" 4'-13/4" 9'-11"
12'-8
3/8"
12'-1
15/8"
10'-1
"4'
-101/
2"5'
-105/
8"15
'-17/
8"20
'-35/
8"9'
-57/
8"1'
-81/
2"5'
-3"
12'-5
"5'
-10"
22'-7" 13'-21/4" 3'-03/4" 18'-8" 10'-6" 10'-6" 10'-6" 7'-6" 3'-0" 9'-6" 2'-05/8" 1'-0" 31'-11 3/8"
14'-10" 5'-6" 1'-0" 8'-111/2" 14'-101/8" 23/8" 5'-2" 1'-17/8" 10'-97/8" 10'-71/2" 7'-13/4" 5'-9" 6'-6" 9'-6" 3'-0" 17'-0" 15'-0"
15'-7" 34'-11" 10'-6" 10'-6" 10'-6" 10'-6" 9'-6" 35'-0"
57'-2" 4" 1'-13/8" 9'-31/4" 7'-83/8"1'-10"
6'-05/8" 15'-10" 23/8" 9'-6" 3'-05/8" 31'-113/8"
28'-7
5/8"
1'-1
03/8"
1'-1
"9'
-1"
7'-1
1"3'
-5"
5'-7
"14
'-8"
9'-6
"14
'-8"
1'-0
3/8"
10'-5
5/8"
3'-0
"25
'-1"
2"
14'-10" 9" 29'-101/4" 4'-8" 63/4" 11'-101/2" 10'-71/2" 1'-21/4" 18'-21/2" 9'-6"
7'-6
7/8"
11'-3
1/4"
8'-2
7/8"
3'-5
"10
'-7"
11'-0
"4'
-0"
20'-0
5/8"
11'-2
3/8"
9'-5
5/8"
73/8"
17/8"
10'-0
3/8"
13'-4
3/4"
1'-0
"
7'-6
7/8"
12'-0
1/8"
9'-0
"3'
-0"
9'-6
"11
'-0"
8'-3
"8'
-45/
8"7'
-5"
11'-2
3/8"
10'-1
3/4"
10'-5
7/8"
2'-1
13/8"
11'-1
"14
'-0"
A1A601
A3A609
D1A604
OFFICE208
OFFICE223
OFFICE222
OFFICE221
STORAGE213
ROOMREST
203
STORAGE219
ELECMECH/
206
OFFICE224
HSKG207
C3A602
C3A602
SCALE:1/8" = 1'-0"A1 SECOND FLOOR PLAN0 4' 8' 16'
N
263.04 sq ft
264.42 sq ft
724.19 sq ft
N
Energy Center
RELATIVE SAFER AREA:Restrooms, interior corridorsaway from windows
OCCUPANT ESTIMATE:468 total occupants locatedin relatively safer areas(using 5 SF per occupant)
LEVELS: Three Levels (Third Level unfinished)CONSTRUCTION: Conventional steel construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
FIRST LEVEL SECOND LEVELNOTES (5 SF per occupant): - Restrooms = 527 SF = 105 occupants - East Corridor = 573 SF = 114 occupants
NOTES (5 SF per occupant): - Restrooms = 527 SF = 105 occupants - East Corridor = 724 SF = 144 occupants
15
352 sq ft352 sq ft
233.5 sq ft
65 sq ft
390.12 sq ft
N
Skills Training Center
RELATIVE SAFER AREA:Locker Rooms, Interiorcorridors away from windows
OCCUPANT ESTIMATE:277 total occupants locatedin relatively safer areas(using 5 SF per occupant)
LEVELS: Two Levels (Second Level unoccupied)CONSTRUCTION: Pre-Engineered Metal Building construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
FIRST LEVEL - NORTHNOTES (5 SF per occupant): - Locker Rooms = 688 SF = 137 occupants - East / West Corridor = 704 SF = 140 occupants
16
6,625 sq ft
464 sq ft
N
Skills Training Center
RELATIVE SAFER AREA:Automotive Lab, Interiorcorridors away from windows
OCCUPANT ESTIMATE:1,417 total occupantslocated in relatively saferareas (using 5 SF peroccupant)
LEVELS: Two Levels (Second Level unoccupied)CONSTRUCTION: Pre-Engineered Metal Building construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
FIRST LEVEL - SOUTHNOTES (5 SF per occupant): - Automotive Lab = 6,625 SF 1,325 occupants - East Corridor = 464 SF = 92 occupants
17
1,640 sq ft
1,520 sq ft
1,536 sq ft
201.5 sq ft 201.5 sq ft
378.49 sq ft350.49 sq ft
203.75 sq ft221.25 sq ft
146.42 sq ft159.75 sq ft
N
Regional Training and Development Center
RELATIVE SAFER AREA:Restrooms, Interior corridorsaway from windows
OCCUPANT ESTIMATE:1,309 total occupants locatedin relatively safer areas (using5 SF per occupant)
LEVELS: One LevelCONSTRUCTION: Pre-Engineered Metal Building construction
NOTES (5 SF per occupant): - West Restrooms = 403 SF 80 occupants - North, Central, South Corridors = 4,696 SF = 939 occupants - Southwest Restrooms = 728 SF = 145 occupants - Southeast Restrooms = 728 SF = 145 occupants
(Assessments are based on generalstructural observations and the followingrecommended areas should not beconstrued as storm shelters or safe roomsbut as areas that may be somewhat saferthan other areas)
18
226.17 sq ft
109.5 sq ft
119 sq ft
N
Vet Tech - Lindale Campus
RELATIVE SAFER AREA:North corridor, Restrooms
OCCUPANT ESTIMATE:89 total occupants located inrelatively safer areas (using5 SF per occupant)
LEVELS: One LevelCONSTRUCTION: Appears to be conventional steel construction
(Assessments are based on general structural observationsand the following recommended areas should not beconstrued as storm shelters or safe rooms but as areas thatmay be somewhat safer than other areas)
NOTES (5 SF per occupant): - North Corridor = 226 SF 45 occupants - Women's Restroom = 119 SF = 23 occupants - Men's Restroom = 109 SF = 21 occupants