Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 1
Reference Manual Total Eclipse
Preface
This manual has been written and illustrated to present the basic installation, operation and servicing instructions of the Total Eclipse Chemical Management System. Guidelines will be suggested in reference to the preferred method of installation, however, the variety of equipment and the surrounding environment will dictate the actual installation of the Total Eclipse.
Total Eclipse Chemical Management SystemOnline and downloadable Product Manuals and Quick Start Guides are available at www.HydroSystemsCo.com Please check online for the latest version of this Reference Manual.
WARNING:The Total Eclipse controller is intended to be installed by experienced installers, inaccordance with all applicable electrical and plumbing codes.
!
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 2
Table of Contents
1 Contoller Specifications .......................................................................................................................3 2 Installation .............................................................................................................................................3 3 Description of Controls and Operator Menu ......................................................................................6 Warranty ...........................................................................................................................................7 4 Operator Menus ....................................................................................................................................8
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 3
1. Route MI signal wires through 1/2 inch knock-out on washer (within the wiring area). Secure MI to washer with lock nut (provided). Signal wires are to be connected according to instructions in step two below.
2. Plug J2 cable into MI. Bundle excess J2 cable outside washer and connect other end to J2 connector on rear of Controller.
3. Connect J1 cable from pump module to J1 connector on Controller. The maximum length of J cables should not exceed 75 ft. (22.9 m.) unless using a break out box and hard wiring. Contact Hydro Systems for additional cables, a coupler or detailed instructions.
4. Secure J1 and J2 cables to controller tie-down posts with tie wraps.
Installation
Trigger Supply Signal Connect to: Signal Common Stand ard (US) Group (EU)
Signal 1 Black Wire White/Black Pump 1 Group 1Signal 2 Brown Wire White/Brown Pump 2 Group 1Signal 3 Red Wire White/Red Pump 3 Group 2Signal 4 Orange Wire White/Orange Pump 4 Group 2Signal 5 Yellow Wire White/Yellow Pump 5 Group 3Signal 6 Blue Wire White/Blue Pump 6 Group 4
STEP 1: Install the Machine Interface (MI)
STEP 2: Connect Signal Wires
VoltageThe Machine Interface will work with any signal voltage between 24 – 240VAC or 22 – 24VDC. With DC signals, polarity must be observed. Common is negative. The signals should be positive voltages.
Supply Trigger WiringIdentify the washer supply signals. In Standard or Group Mode of Operation, connect Machine Interface wires to machine supply signals using appropriate terminal connectors. Use table below for reference. (Do not use this table for Event or Occurrence Modes; see Manual.)Trigger Signal Wiring Notes:
WARNING/ADVERTENCIA:Keep MI and communication J cables away from high voltage wires and relays. NEVER parallel the J cables with high voltage lines.
Mantenga M.I. y los cables J de comunicación separados de los cables de alta tensión y relés. NUNCA instale el cable J paralelo con las líneas de alta tensión.
!
WARNING/ADVERTENCIA:Always verify all voltage sources with a meter. Electrical wiring connections for supply triggers are to be done inside the junction box.
Siempre verifique la alimentación de corriente con un voltímetro. Las conexiones eléctricas a los disparadores de suministro (supply) deben hacerse dentro del recinto donde se encuentran los suministros (supply).
TOTAL ECLIPSE Controller SpecificationsSize 5'25" W x 4.0" H x 2.5" D (13.4 cm W x 10.2 cm H x 6.4 cm D)Weight 0.65 lb. (0.30 kg)Power Rating SELV — Power source is pumpstand Data Input Field Size 15 characters maximum input for custom namesPump Capacity 99.99 oz. (2999 ml.) 8 pump (with 3 amount settings per pump) maximumEnvironmental IP Rating – 44 Pollution Category – 2 Installation Category – II Temperature 10° to 49° C (50° to 120° F) maximumHumidity 95% relative humidity, maximum Indoor Installation Approved for indoor use only. Must not be installed outdoors.Altitude Install at or below 6,500 ft.
WARNING/ADVERTENCIA:Disconnect all power to the pumpstand during installation, service, and/or any time pump cabinet is opened. The TOTAL ECLIPSE should be installed by a qualified technician only, in accordance with all applicable electrical and plumbing codes.
Desconecte toda la corriente eléctrica al dosificador durante la instalación, servicio y / o siempre que se abra el gabinete de la bomba. El equipo TOTAL ECLIPSE debe ser instalado sólo por técnicos calificados y de acuerdo con todas las normas de plomería y electricidad que apliquen.
!
• If one or more pump signals are not used, they do not need to be connected. Cap any wires that are not used.
• If you are triggering more than one pump from a single signal, connect all MI signal wires for those pumps to that signal.
• If washer has a single common, wire nut all commons together.
!
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 4
STEP 3: Mount the Controller
1. Mount bracket with velcro-style strips, according to the directions at right. Install wall board screws or nuts and allen bolts, if needed.
2. Slide controller down onto mounting bracket until it snaps in place.
3. Install pump module and make all electrical and plumbing connections for the system, but DO NOT apply power to the TOTAL ECLIPSE until you are ready to select a language of operation.
Controller Language Options
Each TOTAL ECLIPSE is shipped with two languages installed: English/Spanish. Additional languages, as they become available, may be obtained by contacting Hydro Systems. If changing from default languages, you will need your language-enabled USB flash drive for the next step.
STEP 4: Select the Controller Menu Language
1. Apply power to pumpstand & power-up Controller. Two available LANGUAGES are displayed. (Optional) To replace the non-English
language, connect a USB flash drive with the new language to the controller’s USB port (under flap on right side of controller).
2. Move the selection box by using the UP or DOWN ARROWS until the correct language is contained within the box.
3. Press ENTER to select a language. All menu and application items are translated into the new language. Text input by the installer (pump and formula name, etc.) remains in the original language and is not translated.
STEP 5: Set the Current Date and Time
1. After the language is set, the DATE & TIME menu appears as YYYY-MM-DD (Year-Month-Day) and HH:MM (Hour:Minute) with the first number of the year selected as the active digit, indicated by the double-arrow cursor.
2. Press the UP or DOWN ARROW to change the active digit. Press the RIGHT ARROW to move the cursor to the next digit. Set all digits until the current Year-Month-Date and Hour:Minute display. NOTE: Time must be set in military time.
3. Press ENTER to save the setting and display the Home Screen.
Installation
Mounting Bracket3 With J1 and J2 cables connected, slide Controller onto mounting bracket until it snaps into place.
1 Attach Velcro-style Strips and Mount
Install Wall Board Screws or Masonry Nuts & Allen Bolts
2 (Optional)
2debracket u
o
ountil it snaps into
1 Attach Velcro-s
e ControMM
oller
2
cables
2
MM
EXIT
LEFT RIGHT
UP
DOWN
ENTER
TOTAL ECLIPSE Keypad
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 5
STEP 6: Program the Controller via USB Flash Drive
The easiest way to program the controller is to load a previously created set-up file from a USB flash drive onto the controller. Settings that are NOT transferred via a USB drive are: Passwords (Installer & Manager); Machine Name; Company Name; Calibration.
1. Connect the USB flash drive containing set up files that were created in either the Formula Editor or on another controller.
2. From the Home Screen, press ENTER to launch the MAIN MENU.3. Move the selection box to INSTALLER MENU by pressing and holding the DOWN ARROW.4. Press ENTER and input the default Installer Password of 01234, using the UP ARROW to increment the
number and the RIGHT ARROW to move the cursor. 5. Press ENTER to accept the password input. Select DATA TRANSFER from the Installer Menu and follow
the sequence below:
6. Remove USB flash drive. Press EXIT to return to the Installer Menu, in order to prime and calibrate (required) pumps.
STEP 7: Prime Pumps
Press ENTER to start and stop prime. After priming is complete, press EXIT until you reach the Home Screen.
STEP 8: Calibrate the Pumps
You must calibrate all pumps to be used; programmed pumps will not run if they are not calibrated. Use CALIBRATE (VOLUME) only for medium (12 or 18 oz. / 355 or 532 ml. per minute) pumps.
Use CALIBRATE (TIME) for large displacement pumps or for a flush installation. Press START and the timer counts down 20 seconds. DO NOT stop the pump; run it for a full 20 seconds, then enter the amount pumped.
Installation
01234
OK EXIT
1. Select Installer Menu
MAIN MENUEMERGENCY PUMP STOPLOAD SIZE: 200 LB USER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS INSTALLER MENU �
Default Home Screen
INSTALLER MENUINSTALLER SERVICEINITIAL SYSTEM SETUPPROGRAM FORMULASDATA TRANSFERSET UNITS OF MEASURE
3. Select Data Transfer2. Input Password
INSTL PASSWORD SETUP FILEPOG RestaurantsBLS ServicesEclipse HotelHospital SettingsInternational HotelAA School District
�
�
DATA TRANSFERWRITE REPORTSREAD SETUPWRITE SETUPUPDATE FIRMWAREWRITE ACTIVITY LOG OK EXIT
4. Display Files on USB 5. Send File to Controller
�
�NOVA CONTROLSF01
�
CALIBRATE (TIME)P1P2P3P4P5P6
DISPENSED VOLUMEENTER AMOUNT PUMPED
00.0 OZ
OK EXIT
6.1 Input Amount Collected
CALIBRATEP2 0.0 20.0WARNING! PLACECONTAINER AT OUTPUT! START/STOP EXIT
6. Run Pump Full 20 Seconds
INSTALLER SERVICESERVICE PUMPSVIEW LOAD WEIGHTVIEW AMOUNT PUMPEDCLEAR DATA LOG
INSTALLER MENUINSTALLER SERVICEINITIAL SYSTEM SETUPPROGRAM FORMULASDATA TRANSFERSET UNITS OF MEASURE
1. Select Installer ServicePUMP CALIBRATIONVIEW CALIBRATIONCALIBRATE (TIME)CALIBRATE (VOLUME)
4. Select Calibration Method3. Select Pump Calibration
SERVICE PUMPSPRIME PUMPPUMP CALIBRATIONNAME PUMPSENTER PRODUCT COSTSDATE TUBE CHANGED
CALIBRATE (VOL.)P1P2P3P4P5P6
5. Select Pump to Calibrate
5. Select Pump to Calibrate
CALIBRATEP2 STOP PUMP AT 8 OZ
WARNING! PLACECONTAINER AT OUTPUT! START/STOP EXIT
6. Collect 8 oz [250 ml]2. Select Service Pumps
�
�
INSTALLER SERVICESERVICE PUMPSVIEW LOAD WEIGHTVIEW AMOUNT PUMPEDCLEAR DATA LOG
INSTALLER MENUINSTALLER SERVICEINITIAL SYSTEM SETUPPROGRAM FORMULASDATA TRANSFERSET UNITS OF MEASURE
1. Select Installer Service 3. Select Prime Pump
SERVICE PUMPSPRIME PUMPPUMP CALIBRATIONNAME PUMPSENTER PRODUCT COSTSDATE TUBE CHANGED
SET PRIME PUMPP1P2P3P4P5P6
5. Select Pump to PrimePRIME
P2
START/STOP EXIT
6. Start/Stop Prime2. Select Service Pumps
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 6
Home ScreenThe Home Screen appears after the controller language has been selected or whenever the controller is ac-tive. If no key is pressed for 15 minutes, Power Save turns off the display’s backlight. Press any key to turn the backlight on and resume normal operation. If the controller is powered off, the last formula selected is the active formula on the Home Screen when power is turned back on. See the following graphic for an explana-tion of the information and symbols that may appear on the Home Screen.
Home Screen (Idle)
Formula Quick-SelectTo prevent errors in data logging or chemical dispensing: Select the correct formula before washer operation starts and be sure that all programmed pumps are triggered during the cycle. (Note: A NO CHEMICAL selection exists after Formula 20 that will allow logging of the load count for special operations).
1. From the Home Screen, press EXIT (also called FORMULA SELECT).
2. Press the UP or DOWN ARROW to move the selection box to the correct formula. All formulas appear, but only formulas with programmed pumps are selectable.
3. Press ENTER to start the formula and return to the Home Screen.4. (Optional) Press ENTER to reach the load weight setting.
Description of Controls and Operator Menu
SELECT FORMULAF01 PADSF02 CURTAINSF03 TOWELSF04 BED LINENF05 BLANKETSF06 TABLE LINEN
HYDRO SYSTEMS F03 TOWELS
_ _ 3 _ _ _
1 2 5 6
43
Formula Quick-Select
Press to Move
SelectionBox
Press to Select
Formula
HYDRO SYSTEMS F03 TOWELS
1 2 _ 5 6_ _ _ _ _ _
HYDRO SYSTEMS F03 RUNNING
_ _ 4 _ _ 2
1 2 _ 5 6
Running Formula — Note that formula name is not shown when runningACTIVE Pump — Currently runningComplete — Box indicates that pump has finished its programmed run
HOT KEYS: Formula Quick-Select Main Menu
Pumps
Trigger Signals
Non-Active Signal Qualified
Signal
Receiving Signal (Unqualified)
Company Name (can be changed during Initial System Setup)
Current Formula (or Next Formula to Run) (Formula number appears if no name is input during Initial System Setup)NON-ACTIVE Pump — Not programmed or calibrated; not in formula
READY Pump — Calibrated and has amount(s) programmed
ERROR in Pump — Pump number is not in formula
HOT KEYS: Formula Quick-Select Main Menu
Pumps
Home Screen (Running)
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 7
Operator Main MenuTo reach the Main Menu from the Home Screen, press any key (except the EXIT key).
Limited Warranty
Seller warrants solely to Buyer the Products will be free from defects in material and workmanship under normal use and service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) and products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event the Products are altered or repaired by Buyer without Seller’s prior written approval, all warranties will be void. No other warranty, oral, express or implied, including any warranty of merchantablilty or fitness for any particular purpose, is made for these products, and all other warranties are hereby expressly excluded.
Seller’s sole obligation under this warranty will be, at Seller’s option, to repair or replace F.O.B. Seller’s facility in Cincinnati, Ohio any Products found to be other than as warranted.
Limitation of Liability
Seller’s warranty obligations and Buyer’s remedies are solely and exclusively as stated herein. Seller shall have no other liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or breach of warranty.
Description of Controls and Operator Menu
Emergency Pump Stop (stops all pumps and formulas).
Load Weight Menu (displays default load weight for formula. Input actual weight at start of each load).
Selection Box—Move box to select menu item. Press ENTER to launch selected menu.
Print Manager Reports—Input Manager password, then FROM/TO date range.
Installer Programs and Settings—Input installer password.
View Load Count—View the number of loads run for each wash formula. The View Load Count text appears on the screen when the selection box is moved down the screen with the DOWN arrow key.Pump Status—View the status and settings of each pump. The PUMP STATUS text appears on the screen beneath VIEW LOAD COUNT when the selection box is moved down the screen using the DOWN arrow key.
RETURN TO HOME SCREEN: Press EXIT or wait 15 seconds without pressing a key.
�MAIN MENUEMERGENCY PUMP STOPLOAD WEIGHT 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUVIEW LOAD COUNTPUMP STATUS
�
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 8
TOTAL ECLIPSE Operator Menus
NOVA CONTROLS
F02 CURTAINS
_ 2 _ _ _ _ �
�
�
EMERGENCY PUMP STOPLOAD WEIGHT 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUVIEW LOAD COUNT
Main Menu (Emergency Pump Stop)
MAIN MENU
�
�
�
SELECT FORMULAF01 PADSF02 CURTAINSF03 TOWELSF04 BED LINENF05 BLANKETSF06 TABLE LINEN
Formula Select
Select& Returnto HomeScreen
Home Screen
LOAD WEIGHT
220 LB
(SINGLE LOAD) OK EXIT
Input Actual Load Weight
SET PRIME PUMPP1 PRE-WASHP2 DETERGENTP3 LIQUID BLEACHP4 BLEACH ALTERNATIVEP5 SOUR/CONDITIP6 ENZYME LIFT
Emergency Pump Stop
MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUVIEW LOAD COUNT
Main Menu (User Prime Pump)
MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUVIEW LOAD COUNT
Main Menu (Load Size)
EMERGENCY STOP
STOP ALL PUMPSAND FORMULAS
STOP EXIT
PRIME P3 LIQUID BLEACH
START/STOP EXIT
Select Pump to Prime (if enabled) Start / Stop Prime Pump
MGR PASSWORD
OK EXIT
Input Manager Password
0 1 2 3�
�00-00-00�
�
�
�
REPORT DATE
OK EXIT
Set Date for Report Header
WASH23 12-10-08
INSERT USB DRIVE
�
�
REPORT NAME
OK EXIT
Set “SAVE AS” File Name & Date
MANUAL FLUSH
START/STOP EXIT
Start/Stop Flush (if flush enabled)
�MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUVIEW LOAD COUNT
Main Menu (User Manual Flush)
�MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUVIEW LOAD COUNT
Main Menu (Manager Reports)
Display returns to Main Menu after data transfer is complete.
1 2 3 X 5 6 7 8 8
�
�
�
�
�MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 275 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENU
VIEW LOAD COUNT
Main Menu (View Load Count) View Load Count
TOTAL LOAD COUNTF01 PADS 0F02 CURTAINS 0F03 TOWELS 0F04 BED LINEN 0F05 BLANKETS 0F06 TABLE LINEN 0
Guide to Keypad & Menus
Pumping(Flush Off)
More Items Flushing Pumping &Flushing
F02 �FO3 FO4 �
SELECTIONBOX UP/DOWN
Arrows MoveSelection Box
ENTER KeyLaunchesMenu Item
ENTER also Starts/Stops
Action
MENUSYMBOLS
HOMESCREEN
=
or
UP/DOWNArrows Input
Value (0-9, A-Z)
LEFT/RIGHTArrows Move
Cursor
ENTERSaves & Exits
EXITOnly
350 LBS�
�
EDITVALUE
=
Steady On
Trigger Signal IconPump Icon
MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 180 LBUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENU
INSTL PASSWORD
0 1 2 3 4
OK EXIT
�
�
Installer Menu Access�
�
HYDRO SYSTEMS
P/N 20-09130-00 Rev. E © Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 9
TOTA
L E
CLI
PS
E
Top
Lev
el In
stal
ler
Men
us(fa
ctor
y d
efau
lt se
ttin
gs s
how
n in
sel
ectio
n b
oxes
)
En
ter
/ Sav
e K
ey-
Laun
ches
sel
ecte
d m
enu
- S
aves
new
inpu
t & e
xits
Up
/ D
ow
n A
rro
w-
Mov
es S
elec
tion
Box
- C
hang
es d
igit
valu
e
Rig
ht
/ Lef
t A
rro
wD
urin
g in
put,
mov
es th
ecu
rsor
(
) to
the
next
dig
it� �
01
234
O
K
E
XIT
Mai
n M
enu
MA
IN M
EN
UE
ME
RG
EN
CY
PU
MP
ST
OP
LOA
D S
IZE
:
175
LB
US
ER
PR
IME
PU
MP
SU
SE
R M
AN
UA
L F
LUS
HM
AN
AG
ER
RE
PO
RT
SIN
STA
LLE
R M
EN
US
Hom
e S
cree
n
INS
TAL
LE
R M
EN
UIN
STA
LLE
R S
ER
VIC
EIN
ITIA
L S
YS
TE
M S
ET
UP
PR
OG
RA
M F
OR
MU
LAS
DA
TA T
RA
NS
FE
RS
ET
UN
ITS
OF
ME
AS
UR
E
Inst
alle
r To
p Le
vel M
enu
Inpu
t Ins
talle
r P
assw
ord
INS
TL
PA
SS
WO
RD
UN
ITS
-ME
AS
UR
ES
AE
/ IM
PE
RIA
L (
LB/O
Z)
ME
TR
IC
(K
G/M
L)
5.
Set
Uni
ts o
f M
easu
re
N
OV
A
F03
TO
WE
LS
_
_
4 _
_
2
1 2
3
_
_
3.1.
2 A
dd P
umps
to F
orm
ula
F01
PU
MP
SP
1 P
RE
-WA
SH
P2
DE
TE
RG
EN
T
P3
LIQ
UID
BLE
AC
H
P4
BLE
AC
H A
LT
P5
SO
UR
/CO
ND
ITI
P
6 E
NZ
YM
E L
IFT
3.1.
3 P
ump
Set
tings
F01
P1
P1
D
ELA
Y
0 0
0 S
EC
P1A
AM
OU
NT
0
0.00
OZ
P1B
AM
OU
NT
0
0.00
OZ
P1C
AM
OU
NT
0
0.00
OZ
PR
OG
RA
M F
OR
MU
LAS
F01
F02
CU
RTA
INS
F03
TO
WE
LS
F04
BE
D L
INE
N
F
05 B
LAN
KE
TS
F06
TA
BLE
LIN
EN
3.
Fo
rmu
la P
rog
ram
min
g
F01
PU
MP
SE
TT
ING
S
SE
T D
EFA
ULT
WE
IGH
TS
ET
CO
UN
T P
UM
PE
DIT
NA
ME
CLE
AR
FO
RM
ULA
3.1
Set
For
mul
a3.
2 D
efau
lt Lo
ad W
eigh
t3.
3 S
et C
ount
Pum
p3.
4 E
dit F
orm
ula
Nam
e3.
5 C
lear
For
mul
a
PO
G R
esta
uran
tsB
LS S
ervi
ces
Ecl
ipse
Hot
elH
ospi
tal S
ettin
gsIn
tern
atio
nal H
otel
AA
Sch
ool D
istr
ict
SE
TU
P F
ILE
4.2
Rea
d S
etup
- S
elec
t File
to
load
from
US
B to
Con
trolle
r4.
3 W
rite
Set
up -
Nam
e F
ile b
eing
sen
t
(fro
m C
ontro
ller t
o U
SB
flas
h dr
ive)
4.5
Dia
gnos
tic A
ctiv
ity L
og
DA
TA T
RA
NS
FE
RW
RIT
E R
EP
OR
TS
RE
AD
SE
TU
PW
RIT
E S
ET
UP
UP
DA
TE
FIR
MW
AR
EW
RIT
E A
CT
IVIT
Y L
OG
4.1
Set
Rep
ort “
FRO
M /
TO”
Dat
e
RE
PO
RT
DA
TE
FR
OM
:
200
9-01
-08
O
K
EX
IT
RE
PO
RT
NA
ME
H
I CA
P W
AS
H
INS
ER
T U
SB
DR
IVE
O
K
EX
IT
4.1.
2 S
et “
SA
VE
AS”
File
Nam
e4.
Upl
oad
/ D
ownl
oad
Dat
a
1.4
Cle
ar D
ata
Log
ZE
RO
DA
TA L
OG
WA
RN
ING
! ALL
LO
GS
(LO
AD
S &
VO
LUM
ES
)W
ILL
BE
CLE
AR
ED
!
O
K
E
XIT
1. S
ervi
ce /
Rou
tine
Mai
nten
ance
INS
TAL
LE
R S
ER
VIC
ES
ER
VIC
E P
UM
PS
VIE
W L
OA
D W
EIG
HT
VIE
W A
MO
UN
T P
UM
PE
DC
LEA
R D
ATA
LO
G
1.1
Pum
p M
aint
enan
ce /S
ervi
ce
SE
RV
ICE
PU
MP
SP
RIM
E P
UM
PP
UM
P C
ALI
BR
AT
ION
NA
ME
PU
MP
SE
NT
ER
PR
OD
UC
T C
OS
TS
DA
TE
TU
BE
CH
AN
GE
D
1.2
Vie
w L
oad
Wei
ght
TOTA
L W
EIG
HT
F01
PA
DS
0
F02
CU
RTA
INS
0
F03
TO
WE
LS
0F
04 B
ED
LIN
EN
0
F05
BLA
NK
ET
S
0F
06 T
AB
LE L
INE
N
0
1.3
Vie
w A
mou
nt P
umpe
d
PU
MP
ED
(G
AL
)P
1 P
RE
-WA
SH
0.
0P
2 D
ET
ER
GE
NT
0.
0P
3 LI
QU
ID B
LEA
C
0.0
P4
BLE
AC
H A
LT
0.0
P5
SO
UR
/CO
ND
ITI
0.0
P6
EN
ZY
ME
LIF
T
0.0
0 1
2 3
4
O
K
EX
IT
�
�
INS
T P
AS
SW
OR
D
�
�
�
�
�
�M
GR
PA
SS
WO
RD
2.5
Edi
t Mac
hine
Nam
e2.
1 E
dit I
nsta
ller P
assw
ord
2.2
Edi
t Man
ager
Pas
swor
d2.
3 S
et-u
p O
pera
ting
Mod
e
HO
TE
L E
CLI
PS
E -
67
O
K
EX
IT
�
�
AC
CO
UN
T N
AM
E2.
4 E
dit A
ccou
nt N
ame
2.6
Edi
t Com
pany
Nam
e
2.8
Set
Cyc
le T
ime
Lim
it
9 0
MIN
UT
ES
(0 =
OF
F)
O
K
EX
IT
�
�
CY
CL
E T
IME
LIM
IT2.
9 S
et T
rigge
r Sig
nal F
ilter
2 S
EC
ON
DS
10 S
EC
ON
DS
20 S
EC
ON
DS
30 S
EC
ON
DS
60 S
EC
ON
DS
90 S
EC
ON
DS
TR
IGG
ER
FIL
TE
R2.
10 A
uto-
For
mul
a S
elec
t2.
11 U
ser
Prim
e E
nabl
e2.
12 A
djus
t Scr
een
Con
trast
2.13
Set
Dat
e &
Tim
e
SY
ST
EM
SE
TU
PE
DIT
INS
T P
AS
SW
OR
D
ED
IT M
GR
PA
SS
WO
RD
O
PE
RA
TIO
N M
OD
EE
DIT
AC
CO
UN
T N
AM
EE
DIT
MA
CH
INE
NA
ME
ED
IT C
OM
PA
NY
NA
ME
SE
T P
UM
P IN
TE
RFA
CE
SE
T C
YC
LE T
IME
SIG
NA
L F
ILT
ER
TIM
ES
ET
AF
S T
RIG
GE
RS
ET
US
ER
PR
IME
SE
T L
CD
CO
NT
RA
ST
SE
T D
AT
E A
ND
TIM
EC
LEA
R S
ET
TIN
GS
VIE
W S
OF
TW
AR
E ID
� �
�
2.
Init
ial
Sys
tem
Se
tup
�
�
�
�
SE
TU
P N
AM
E
H
OT
EL
17
INS
ER
T U
SB
DR
IVE
O
K
EX
IT
�
�
�
� RE
PO
RT
DA
TE
TO
:
200
9-02
-08
O
K
EX
IT
�
�
STA
ND
AR
DR
ELA
YE
VE
NT
GR
OU
PO
CC
UR
RE
NC
E
OP
ER
AT
ION
MO
DE
2.7
Set
Pum
p In
terfa
ce
(and
Flu
sh T
ime,
if n
eede
d)
NO
N-F
LUS
HE
CLI
PS
E F
LUS
H P
. I.
OR
ION
I I
FLU
SH
P. I
.8-
PU
MP
FLU
SH
P. I
.
PU
MP
INT
ER
FAC
E
Ove
rwrit
es �
le o
f sam
e na
me
on U
SB �
ash
driv
e.
Doe
s not
tran
sfer p
assw
ords
, m
achi
ne n
ame,
com
pany
na
me
or c
alib
ratio
ns.
Ove
rwrit
es A
LL se
tting
s &
form
ulas
, exc
ept p
assw
ords
, m
achi
ne n
ame,
com
pany
na
me
& c
alib
ratio
ns.
2
00
9-0
7-2
8
17
:06
Y
YY
Y-M
M-D
D
H
H:M
M
O
K
EX
IT
DA
TE
& T
IME
2.14
Cle
ar C
ontro
ller S
ettin
gs
WA
RN
ING
! ALL
SE
TU
PS
W
ILL
BE
CLE
AR
ED
TO
FAC
TO
RY
DE
FAU
LTS
!
O
K
EX
IT
CL
EA
R S
ET
TIN
GS
F01
LO
AD
WE
IGH
T
0 0
0 L
B
O
K
E
XIT
�
�
NA
ME
F01
NE
W N
AM
E
O
K
EX
IT
�
�
P2
DE
TE
RG
EN
T
�
P3
LIQ
UID
BLE
AC
H
P4
BLE
AC
H A
LT
P5
SO
UR
/CO
ND
ITI
P
6 E
NZ
YM
E L
IFT
P7
�
F01
CO
UN
T P
UM
PC
LE
AR
F01
WA
RN
ING
! FO
RM
ULA
W
ILL
BE
CLE
AR
ED
TO
FAC
TO
RY
DE
FAU
LT!
O
K
E
XIT
UP
DA
TE
FIR
MW
AR
E
ST
OP
!!! D
O N
OT
PR
OC
EE
D W
ITH
OU
TP
C U
PD
AT
E P
RO
GR
AM
!
O
K
EX
IT
RE
PO
RT
NA
ME
A
BB
A
INS
ER
T U
SB
DR
IVE
O
K
EX
IT
�
�
4.4
Upd
ate
Firm
war
e
0
(0
= O
FF
)
OK
E
XIT
AF
S T
RIG
GE
RD
ISA
BLE
EN
AB
LELI
MIT
ED
30
SE
C
O
K
EX
IT
SE
T U
SE
R P
RIM
E
�
��
�
5 0
O
K
EX
IT
LC
D C
ON
TR
AS
T
0
1 2
3
O
K
EX
IT
H
OU
SE
KE
EP
ING
01
O
K
EX
IT
�
�MA
CH
INE
NA
ME
N
OV
A
O
K
EX
IT
�
�
CO
MPA
NY
NA
ME
WA
RN
ING
! D
O N
OT
atte
mpt
firm
war
e up
date
unl
ess
you
have
you
rP
C U
pdat
e P
rogr
am a
nd
prop
er c
ompu
ter
cabl
e.
�
�
�TO
TE
ST
HY
DR
O S
YS
TE
MS
HY
DR
O S
YS
TEM
S