274
TOTALINE® CAPACITORSRUN CAPACITORSOVAL MOTOR RUN CAPACITORS
MFDMAX. CAN
HEIGHT (in.)P/N
370 VOLT SINGLE3 2.12 P291-03034 2.7 P291-04035 2.7 P291-0503
7.5 3.6 P291-075310 4.0 P291-1003
12.5 4.9 P291-125315 5.6 P291-1503
17.5 4.9 P291-175320 4.9 P291-200325 0.4 P291-250330 4.9 P291-300335 5.4 P291-350340 4.9 P291-400345 5.3 P291-450350 5.9 P291-500355 5.9 P291-5503
440 VOLT SINGLE2 2.12 P291-02043 2.12 P291-03044 3.1 P291-04045 3.6 P291-0504
7.5 5.0 P291-075410 4.9 P291-1004
12.5 4.9 P291-125415 5.3 P291-1504
17.5 6.3 P291-175420 4.9 P291-200425 5.3 P291-250430 5.9 P291-300435 5.9 P291-350440 4.9 P291-400445 4.9 P291-450450 5.9 P291-500455 5.9 P291-5504
740 VOLT SINGLE12.5 9.0 P291-1257
SINGLE
• NON-PCB DIELECTRIC FLUID
• UL APPROVED CURRENT INTERRUPTER
• MULTIPLE ELECTRICAL TERMINALS
VAC
1 =2 =3 = 3704 = 4405 =6 =7 = 7408 =9 =
PART NUMBER SIGNIFICANCE
RUNCAPACITOR
MFD
R = ROUNDNO LETTER = OVAL
P 2 9 1 -
P238
DUAL
MFD MAX.CANHEIGHT (in.)
P/NCOMP. FAN
370 VOLT DUAL3 2 2.8 P291-0323
15 5 3.9 P291-155315 7.5 4.9 P291-157315 10 6.8 P291-151315 12.5 5.9 P291-1523
17.5 4 5.8 P291-174320 5 4.0 P291-205320 10 7.7 P291-201325 3 4.7 P291-203325 4 4.9 P291-254325 5 4.9 P291-255325 7.5 4.9 P291-257325 10 5.3 P291-251325 12.5 4.9 P291-252330 5 4.9 P291-305330 7.5 4.9 P291-307330 10 5.1 P291-301335 4 4.7 P291-354335 5 4.9 P291-355335 7.5 4.9 P291-357335 12.5 4.9 P291-352340 5 5.4 P291-405340 7.5 5.4 P291-407340 10 5.3 P291-401345 5 5.9 P291-455345 7.5 5.9 P291-457345 10 5.9 P291-451350 5 5.7 P291-505355 5 5.3 P291-5553
440 VOLT DUAL15 3 6.0 P291-153415 5 4.9 P291-155420 5 4.9 P291-205420 7.5 5.4 P291-207425 5 5.9 P291-255425 7.5 5.9 P291-257430 5 5.9 P291-305430 7.5 5.9 P291-307430 10 4.7 P291-301435 5 5.9 P291-355435 7.5 5.9 P291-357435 10 5.9 P291-351440 5 5.9 P291-405440 7.5 5.9 P291-407440 10 5.3 P291-401445 5 5.9 P291-455450 10 5.3 P291-501450 5 5.3 P291-5054
• NON-PCB DIELECTRIC FLUID
• UL APPROVED CURRENT INTERRUPTER
• MULTIPLE ELECTRICAL TERMINALS
P239
®
275
TOTALINE® CAPACITORSRUN CAPACITORSROUND MOTOR RUN CAPACITORS
SINGLE
MFDMAX CAN
HEIMGHT (in.)P/N
370 VOLT SINGLE5 2.9 P291-0503R
10 2.9 P291-1003R15 3.7 P291-1503R30 6.8 P291-3003R35 3.9 P291-3503R50 5.2 P291-5003R
440 VOLT SINGLE60 - P291-6004R40 - P291-4504RS
VAC
1 =2 =3 = 3704 = 4405 =6 =7 = 7408 =9 =
PART NUMBER SIGNIFICANCE
RUNCAPACITOR
MFD
R = ROUND
P 2 9 1 -
• NON-PCB DIELECTRIC FLUID
• UL APPROVED CURRENT INTERRUPTER
• MULTIPLE ELECTRICAL TERMINALS
P240
DUAL
MFD MAX.CANHEIGHT (in.)
P/NCOMP. FAN
370 VOLT DUAL15 5 5.0 P291-1553RS20 5 2.9 P291-2053R25 5 5.8 P291-2553R25 7.5 5.4 P291-2573R25 10 5.4 P291-2513R30 5 5.8 P291-3053R30 7.5 5.8 P291-3073R35 5 6.4 P291-3553R35 7.5 6.4 P291-3573R40 5 5.0 P291-4053R45 4 6.9 P291-4543R45 5 6.9 P291-4553R50 5 7.3 P291-5053R
440 VOLT DUAL30 5 - P291-3054R15 5 - P291-1554RS55 5.9 - P291-5514RS
• NON-PCB DIELECTRIC FULID
• UL APPROVED CURRENT INTERRUPTER
• MULTIPLE ELECTRICAL TERMINALS
P241
276
TOTALINE® CAPACITORSSTART CAPACITORS
MFD RANGE DIAMETER (in.) LENGTH (in.) P/N
115 VOLTS321-421 1.81 3.37 P281-3211
125 VOLTS21-25 1.43 2.75 P281-210725-30 1.43 2.75 P281-250730-36 1.43 2.75 P281-300736-43 1.43 2.75 P281-360743-56 1.43 2.75 P281-430756-72 1.43 2.75 P281-560772-88 1.43 2.75 P281-7207
88-108 1.43 2.75 P281-8807108-130 1.43 2.75 P281-1087124-156 1.43 2.75 P281-1247145-175 1.43 3.37 P281-1457161-193 1.43 3.37 P281-1617189-227 1.43 3.37 P281-1897200-240 1.43 3.37 P281-2007216-259 1.81 3.37 P281-2167233-280 1.81 3.37 P281-2337240-260 1.43 3.37 P281-2407270-324 1.81 3.37 P281-2707301-360 2.56 4.37 P281-3017324-388 1.43 4.37 P281-3247340-408 1.81 3.37 P281-3407378-454 1.81 3.37 P281-3787400-480 1.81 3.37 P281-4007431-516 1.81 3.37 P281-4317460-552 1.81 3.37 P281-4607540-648 1.81 4.37 P281-5407590-708 1.81 4.37 P281-5907708-850 1.81 4.37 P281-7087
160 VOLTS88-108 1.43 3.37 P281-8801
PART NUMBER SIGNIFICANCE
STARTCAPACITOR
MFD
VAC1 = 115 6 = 3302 = 220 7 = 1253 = 370 8 =4 = 440 9 =
(with bleed resistor)
5 = 250
MFD RANGE DIAMETER (in.) LENGTH (in.) P/N
250 VOLTS31-37 1.43 3.37 P281-310538-46 1.43 3.37 P281-380553-64 1.81 3.37 P281-5305
88-108 1.81 4.37 P281-8802*88-108 1.81 4.37 P281-8805
108-130 1.81 4.37 P281-1085124-149 2.06 4.37 P281-1245130-156 2.56 4.37 P281-1305145-175 2.56 4.37 P281-1455161-193 2.56 4.37 P281-1615189-227 2.56 4.37 P281-1895200-240 2.06 4.37 P281-2005216-259 2.06 4.37 P281-2162*216-259 2.06 4.37 P281-2165233-292 2.06 4.37 P281-2335270-324 2.56 4.37 P281-2705301-360 2.06 4.37 P281-3015324-388 2.56 4.37 P281-3245340-408 2.56 4.37 P281-3405378-454 2.56 4.37 P281-3785400-480 2.56 4.37 P281-4005430-516 2.56 4.37 P281-4305460-552 2.56 4.37 P281-4605540-648 2.56 4.37 P281-5405590-708 2.56 4.37 P281-5905
* 220 volts.
330 VOLTS21-25 1.43 3.37 P281-210643-53 1.43 3.37 P281-4306*61-72 1.81 3.37 P281-6106*64-77 1.81 4.37 P281-6406*72-88 1.81 4.37 P281-720675-90 1.81 4.37 P281-7506
88-108 2.06 4.37 P281-8806108-130 2.56 4.37 P281-1086124-149 2.56 4.37 P281-1246135-155 2.56 4.37 P281-1356*145-175 2.56 4.37 P281-1456161-193 1.43 2.75 P281-1616189-227 2.06 4.37 P281-1896200-240 2.06 5.24 P281-2006216-259 2.06 5.24 P281-2166233-280 2.56 4.37 P281-2336240-266 2.56 4.37 P281-2406270-324 2.56 4.37 P281-2706300-360 2.56 4.37 P281-3006324-388 2.56 4.37 P281-3246340-408 2.56 4.37 P281-3406378-454 2.56 4.37 P281-3786401-480 2.56 4.37 P281-4016
* 320 volts.
P 2 8 1 -
P242
277
TOTALINE® CAPACITOR/ACCESSORIESSTART KIT
START CAPACITOR START RELAYP/N
MFD RANGE VOLTS CONTACT RATING MAX OPER. VOLTS PICKUP VOLTS DROPOUT VOLTS21-25 330 50 AMP 336 162-175 55-115 P296-000743-53 320 35 AMP 336 162-175 40- 90 P296-000643-53 320 50 AMP 395 180-195 40-105 P296-000172-88 330 35 AMP 336 162-175 40- 90 P296-001288-108 330 35 AMP 336 162-175 40- 90 P296-000588-108 330 50 AMP 420 195-224 60-123 P296-000288-108 330 50 AMP 395 180-195 40-105 P296-000488-108 330 50 AMP 336 162-175 55-115 P296-0009
108-130 330 50 AMP 420 195-224 70-140 P296-0010135-155 320 50 AMP 420 195-224 60-123 P296-0003145-175 330 50 AMP 395 180-195 40-105 P296-0008189-227 330 50 AMP 420 262-290 60-121 P296-0011
Totaline start kits are for use with PSC compressors requiring additional starting torque.
Totaline start kits are available for the most popular Copeland, Tecumseh, Bristol, and Carlyle compressors.
The kit contains the following:
• START CAPACITOR
• START RELAY
• WIRE KIT(1) Black Wire 54 IN. Long(1) Brown Wire 16 IN. Long(1) Blue Wire 38 IN. Long(1) Brown Wire 30 IN. Long
• END CAP
• BRACKET
• INSTRUCTION SHEET
WIRE KIT
BRACKET END CAP BOOT
An assortment of wires to be used to connect a start relay and start capacitor to a unit for hard start capability.
P/N: P421-4012 P/N: P421-4013(1) Black Wire 44 IN. Long (1) Black Wire 54 IN. Long(1) Blue Wire 22 IN. Long (1) Brown Wire 16 IN. Long(1) Black Wire 14 IN. Long (1) Blue Wire 38 IN. Long(1) Yellow Wire 29 IN. Long (1) Brown Wire 30 IN. Long
P244
PART NAME USE WITH CAPACITOR P/N:Start Capacitor Bracket 3-3/8″ Long P281-0017Start Capacitor Bracket 4-3/8″ Long P281-0016Capacitor End Cap 1-13/16″Diameter P281-0011Capacitor End Cap 2-1/16″ Diameter P281-0012Capacitor End Cap 2-9/16″ Diameter P281-0013Terminal Boot Single Oval Top Outlet P281-0002Terminal Boot Single Oval (2) Side Outlets P281-0003Terminal Boot Single Round P281-0006Terminal Boot Dual Oval P281-0004
P245P246 P247
START THERMISTER
STRAP
This 25 OHM PTC device provides additional starting torque for compressors.
Connects in parallel to run capacitor
P/N: P421-4006P248
P249
P243
PART NAME USE WITH CAPACITOR P/N:Mounting Strap 1.21″ x 2.06″ Oval P281-0022Mounting Strap 1.81″ x 2.81″ Oval P281-0021Mounting Strap 1.87″ x 3.56″ Oval P281-0028Mounting Strap 15″ FIT ALL P281-0025
Wrap Around Mounting Strap
.63″ x 2.05″ Oval P281-0023
Wrap Around Mounting Strap
.91″ x 2.80″ Oval P281-0024
Wrap Around Mounting Strap
1.58″ Wide .95 x 3.59″ Oval P281-0026
278
RELAYSRELAY APPLICATION DATACONTROL RELAYS
CONTACT ARRANGEMENT DIAGRAMS
The main function of any relay is switching electrical circuits. Selection depends primarily on load characteristics which should be matched closely to the rating of the relay to avoid contact point deterioration.
Relay ratings in amperes are listed in this brochure as inductive or resistive.
Inductive Rating - applies to switching of motors and coils for contactors and relays.
Resistive Rating - applies to switching of electric resistance heating elements.
The relays shown on the following pages have been classified into two major categories, power rated relays for intermediate loads and pilot duty relays for low level switching.
Pilot Duty Relays: Contacts are made of a fine silver alloy and are shaped and sized for low level current switching. The fine sil-ver alloy contact provides a very low surface resistance for the best possible contact life. Use on higher or intermediate loads would melt the relay points causing a welded contact.
Power Rated Relays: Contacts are generally made of silver cadmium oxide with a very high surface resistance. They are sized larger than pilot duty contacts to handle switching of inter-mediate loads during which a slight arc may occur. Due to being larger in size, they must operate with a lower unit pressure on the contacts and, for satisfactory performance, depend on the make-break arc process to break down the resistance of depos-its formed on the contacts.
Use of this type relay to switch low level loads is not recom-mended by Carrier or its suppliers due to the lower contact pressure, the high surface resistance of the contacts and the absence of the slight arc during switching. A continuing build-up of deposits on contact points will cause a non-conductive sur-face and a failed relay. In some instances a power rated relay will fail to switch a pilot duty load on initial use.
For reliable relay operation, it’s advisable not to use a power rated relay for a pilot duty relay or vice versa.
(DB) - Indicates contacts are Double Break type in which stationary contacts are connected by a bridging bar. Two examples of a double break arrangement are shown below with contacts #1 and #2 stationary. Both are SPST, normally closed, double break arrangements.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
SPST
SPST
SPDT
DPST
DPST
DPST
DPDT
TPST
TPST
TPDT FPDT
1 2
Connects 1 to 2 only Connects 1 and 2 to 3
1 2
3
279
TOTALINE® RELAYSFAN & POWER RELAYS
GENERAL PURPOSE RELAY
Dependable, low cost solution for air conditioning and heating switching.
Insulating Material -Constructed of UL recognized Class B insulating material
Temperature Range --40 to 150 Fahrenheit
SINGLE POLE FAN RELAYS- SIMILAR TO TYPE 84 FAN RELAYS
TWO POLE FAN RELAYS
CONTACT RATING 125/250 VAC DESCRIPTION P/N8 AMPS (IND.) 16 AMPS (RES.) SPST, 24 V COIL P283-0290
CONTINUOUS SPST, 110/240 V COIL P283-029125 AMPS INRUSH SPST, 208/240 V COIL P283-0292
8 AMPS (IND.) 8 AMPS (RES.) SPDT, 24 V COIL P283-0293CONTINUOUS SPDT, 110/120 V COIL P283-0294
18 AMP INRUSH SPDT, 208/240 V COILS P283-0295
TERMINALS 1-2-3 TERMINALS 4-5-6 DESCRIPTION P/NPOWER POWER 24 V COIL P283-0340POWER POWER 110/240 V COIL P283-0341POWER POWER 208/240 V COIL P283-0342POWER PILOT 24 V COIL P283-0343POWER PILOT 110/240 V COIL P283-0344POWER PILOT 208/240 V COIL P283-0345PILOT PILOT 24 V COIL P283-0346PILOT PILOT 110/240 V COIL P283-0347PILOT PILOT 208/240 V COIL P283-0348
* Fan control* Appliances* Business Machines* Photoelectric control and general
purpose switching
* Vending machines* Appliances* Safety control* Fan control* Heating* Air conditioning and general
purpose switching
HEAVY DUTY FAN RELAYS
CONTACT ARRANGEMENT DESCRIPTION P/NSPDT - NO 24 V COIL P283-0360SPDT - NO 24 V COIL P283-0370
SPNO - SPNC 24 V COIL P283-0380
P262-B
P262-A
®
280
TOTALINE® RELAYS/ACCESSORIES
TOTALINE® START RELAYS
TOTALINE WIRE KIT
• SINGLE POLE, NORMALLY CLOSED RELAYS
• TOTALLY ENCLOSED
• CONTACTS RATED FOR A MAXIMUM ARC RUPTURING CAPACITY AT 600 VAC AND UNDER
• 1/4 IN. QUICK CONNECT TERMINALS
• G.E. 3ARR3 TYPE AND RBM 128000 TYPE
• 50/60 Hz
CONTACT ARRANGEMENT DIAGRAM:
1 2 5
c
2-1/4″″″″H x 2-1/4″″″″W x 2-7/16″″″″D
CONTACT RATING PICKUP VOLTS DROPOUT VOLTS MAX. OPER. VOLTS P/N 35 Amp 162 - 175 40 - 90 336 P283-9924 15 Amp 180 - 195 40 - 105 375 P283-9928 25 Amp 111 - 124 20 - 45 170 P283-9926 50 Amp 140 - 152 33 - 77 253 P283-9916 50 Amp 162 - 175 55 - 115 336 P283-9917 50 Amp 171 - 184 40 - 90 336 P283-9919* 50 Amp 180 - 193 55 - 115 336 P283-9921 50 Amp 180 - 195 40 - 105 395 P283-9923 50 Amp 195 - 224 60 - 123 420 P283-9915 50 Amp 204 - 233 60 - 121 420 P283-9913* 50 Amp 223 - 254 60 - 140 395 P283-9922 50 Amp 239 - 268 60 - 135 495 P283-9918* 50 Amp 262 - 290 60 - 121 420 P283-9914* 50 Amp 277 - 305 75 - 150 495 P283-9912 50 Amp 295 - 324 60 - 135 495 P283-9911*
P263
An assortment of wires to be used to connect a start relay and start capacitor to a unit to obtain hard start capability.
P/N: P421-4012 P/N: P421-4013(1) BLACK WIRE 44 IN. LONG (1) BLACK WIRE 54 IN. LONG(1) BLUE WIRE 22 IN. LONG (1) BROWN WIRE 16 IN. LONG(1) BLACK WIRE 14 IN. LONG (1) BLUE WIRE 38 IN. LONG(1) YELLOW WIRE 29 IN. LONG (1) BROWN WIRE 30 IN. LONG
P244
281
TOTALINE® RELAYS/ACCESSORIESRBM TYPE 75 RELAYS
RBM TYPE RELAYS 84 AND 184
• POWER DUTY APPLIANCE RELAY
• OPERATES IN ANY POSITION
• CONTACT TERMINALS ARE SCREW TYPE
CONTACT ARRANGEMENT DIAGRAM:
(5)
DPST
*See contact arrangement diagram.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM TERMINAL P/NINDUCTIVE RESISTIVE
120 V 240 V 120 V 240 V18 18 25 25 115 DPST 5 LEADS HN61VA067
2-1/2″″″″H x 2-1/2″″″″W x 3-3/16″″″″D
P250
• BANTAM RELAY DESIGNED FOR COMPACTNESS
• TOTALLY ENCLOSED
• OPERATES IN ANY POSITION
• 1/4″ QUICK CONNECT TERMINALS
CONTACT ARRANGEMENT DIAGRAMS:
(3)
SPDT
(1)
SPST(4)
DPST
POWER DUTY
*See contact arrangement diagrams.**HN61KJ024 same as HN61KJ250 but with screw terminals.
PILOT DUTY
*See contact arrangement diagrams.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
120 V 240 V 120 V 240 V12 8 18 18 24 DPST 4 HN61KQ12012 8 18 18 24 SPDT 3 HN61KJ250**12 8 18 18 120 SPDT 3 HN61KJ51012 8 18 18 240 SPST 1 HN61KA24012 8 18 18 240 SPDT 3 HN61KJ02312 8 18 18 277 DPST 4 HN61KQ121
CONTACT RATING (FLA)COIL VOLTS
CONTACT ARRANGEMENT*
DIAGRAM P/NINDUCTIVE RESISTIVE
125 VA @ 125/250 V 3A @ 125 V 24 SPDT 3 HN65KJ016125 VA @ 125 V,277 VA @ 277 V
3A @ 277 V 24 DPST 4 HN61KK324
125 VA @ 125/250 V 3A @ 125 V 240 SPDT 3 HN65KJ015
1-9/16″″″″H x 1-1/2″″″″W x 2-7/16″″″″D
P251
282
TOTALINE® RELAYS/ACCESSORIESRBM TYPE RELAYS 91 & 192, HONEYWELL TYPE RELAYS R4222 & R8222
• SEMI-ENCLOSED CONSTRUCTION
• 1/4 IN. QUICK CONNECT TERMINALS
• THE SINGLE AND DOUBLE POLE RELAYS MAY BE USED WITH PLUG-IN RECEPTACLE PACKAGE 48DA660033
CONTACT ARRANGEMENT DIAGRAMS:
(1) (3) (6)(8)
(10)SPST
SPDT DPST
TPDT
TPST
(7)
DPDT
2-1/4″ ″ ″ ″ H x 2-1/8″ ″ ″ ″ W x 1-7/8″ ″ ″ ″ D
POWER DUTY
*See contact arrangement diagrams.**480 V rating applies only to HN61KK066.
PILOT DUTY
*See contact arrangement diagrams.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
120 V 240 V 120/240/277 V12 6 15 24 SPST 1 HN61KA01016 18 25/25/25 24 SPST 1 HN61KA01616 18 25/25/25 208-230 SPDT 3 HN61DJ230
3 @ 480 V** 10 @ 480 V**24 DPDT 7 HN61KK066
12 6 15 @ 277 V12 6 15 @ 277 V 24 DPDT 7 HN61KK91112 6 15 @ 277 V 120 DPDT 7 HN61KK91212 6 15 @ 277 V 240 DPDT 7 HN61KK913
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
125/250 V 277 V125 VA @ 120-480 V 3A 24 SPST 1 HN61DA480
125 VA 3A 24 DPDT 7 HN61KK040125 VA 3A 120 DPDT 7 HN61KK041125 VA 3A 240 DPST 6 HN61KX010
P252
283
TOTALINE® RELAYS/ACCESSORIESRBM TYPE 91 & 192 RELAYS, HONEYWELL R4222 & R8222 RELAYS
RBM TYPE 91 RELAYS
CONTACT RATING (FLA)
POWER: INDUCTIVE 12A @ 120 V
6A @ 240 V
RESISTIVE 15A @ 277 V
PILOT: INDUCTIVE 125 VA @ 125/250 V
RESISTIVE 3A @ 277 V
NOTE: SPDT has power rated normally open contact and pilot duty normally closed contact.*Power Contacts: Inductive, 20A/10A @ 120V/250 VResistive, 25A @ 120V/277 V
COIL VOLTSCONTACT
ARRANGEMENT’P/N
208/230 SPST (pilot)
SPDT (power)HN61KP003
24SPDT (power)SPDT (pilot)
HN61KP011
24SPDT N.C. (power)
N.O.(pilot)HN61KJ006
120SPDT (power)SPDT (pilot)
HN61KP012
240SPDT (power)SPDT (pilot)
HN61KP010
240SPDT (power)SPST (pilot)
HN61KP004
• SEMI-ENCLOSED
• 1/4 IN. QUICK CONNECT TERMINALS
1
3
4
56 9
7 1
3
4
65
1
3
4
62 5
HN61KL001 HN61KP010,011,012 HN61KP003
2-1/4″″″″H x 2-1/8″″″″W x 1-7/8″″″″D
P253
• SPECIAL QUIET OPERATING POWER RELAY FOR ELECTRIC HEAT APPLICATIONS
• IMPORTANT THE HN61DC024 (DPST) RELAY IS DESIGNED TO OPERATE ONLY ONE INDUCTIVE LOAD. THE INDUCTIVE RATINGS AND THE COMBINED INDUCTIVE AND RESISTIVE RATINGS IN THE CHART MAY BE APPLIED TO ONLY ONE OF EITHER POLE OF THIS RELAY.
• 24 V, 6.2 VA HOLDING COIL
CONTACT ARRANGEMENT DIAGRAM:
(5)
DPST
*See contact arrangement diagram.
CONTACT RATINGCOMBINED INDUCTIVE
AND RESISTIVE CONTACTARRANGEMENT*
DIAGRAM P/NVOLTAGE INDUCTIVE RESISTIVE COMBINED INDUCTIVE ONLY
120,240,277 7.0 25.0 26.0 6.4DPST 5 HN61DC024480 3.5 12.5 13.6 3.2
600 2.8 10.0 10.4 2.56
P254
284
TOTALINE® RELAYS/ACCESSORIESRBM TYPE 93 RELAYS, POTTER BRUMFIELD TYPE KU93 RELAYS
• MAY BE USED WITH THE RECEPTACLE PACKAGES LISTED BELOW
• 3/16 IN. QUICK CONNECT TERMINALS
RECEPTACLE PACKAGES (include quick connects)
CONTACT ARRANGEMENT DIAGRAMS:
COLOR VOLTAGE P/N
Black 24 48DA660026Red 115 48DA660028
Green 208-240 48DA660027
(1)
SPST
(7)
DPDT
(3)
SPDT
(10)
TPDT
(11)
FPDT
POWER DUTY
NC = NORMALLY CLOSED CONTACTS *See contact arrangement diagram.NO = NORMALLY OPEN CONTACTS **Removable mounting bracket attached.
PILOT DUTY
*See contact arrangement diagrams. ‡Mounting bracket, not removable.†Has neon indicator light. ††Gold diffused contacts.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
120 V 240 V 120 V 240 V10 5 10 5 24 DPDT 7 HN61KK03010 5 10 5 24 TPDT 10 HN61KL030
5 (NC) 5 (NC) 5 (NC) 5 (NC)24 TPDT 10 HN61KL038**
5 (NO) 3 (NO) 3 (NO) 3 (NO)10 5 10 5 120 TPDT 10 HN61KL03110 5 10 5 240 TPDT 10 HN61KL032
5 (NC) 5 (NC) 5 (NC) 5 (NC)240 TPDT 10 HN61KL041**
5 (NO) 3 (NO) 3 (NO) 3 (NO)
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
125/250 V 250 V125 VA 5A/3A @ 125/250 V 24 SPST 1 HN61KA002125 VA 3A 208/230 TPDT 10 HN61KL022125 VA 3A 24 TPDT 10 HN61KL604125 VA 3A 24 TPDT 10 HN61KL704125 VA 3A 120 TPDT 10 HN61KL615125 VA 3A 120 TPDT 10 HN61KL616†125 VA 3A 240 TPDT 10 HN61KL630125 VA 5A/3A 24 TPDT 10 HN61KL023‡††125 VA 5A/3A 120 TPDT 10 HN61KL620‡125 VA 5A/3A 24 SPDT 3 HN61KP023††
1-15/16″″″″H x 1-9/16″″″″W x 1-7/16″″″″DP255
285
TOTALINE® RELAYS/ACCESSORIESPOTTER BRUMFIELD TYPE PRD RELAYS
RBM TYPE 129000 RELAYS
POWER DUTY
*See contact arrangement diagrams.
PILOT DUTY
*See contact arrangement diagrams.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
120 V 240 V 120 V 240 V18 18 18 18 24 DPST 4 HN61KR91118 18 18 18 120 DPST 4 HN61KJ00318 18 18 18 240 DPST 4 HN61KR91318 18 18 18 277 DPST 4 HN61KJ005
CONTACT RATING INDUCTIVE 125/250 V: 125 VACOIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/N
24 DPST 4 HN61KR-901
*See contact arrangement diagrams.
CONTACT RATING (FLA) HOLDING COIL CONTACTARRANGEMENT*
DIAGRAM P/NINDUCTIVE RESISTIVE VOLTS POWER
20A @ 240/277 V10A @ 600 V 24 9.8 VA SPST 2 HN61PB03020A @ 277 V 240 9.8 VA DPDT 7 HN61PK240
• HEAVY DUTY POWER RELAY
• SCREW TERMINAL - HN61PB030 1/4 IN. Q.C. - HN61PK240
• 2.5″W x 2.2″D x 2.3″H - HN61PB030
• 2.5″W x 3.4″D x 2.5″H - HN61PK240-277
CONTACT ARRANGEMENT DIAGRAMS:
(2)
SPST
(7)
DPDT
P256
• DOUBLE BREAK CONTACT
• TOTALLY ENCLOSED
• 1/4 IN. QUICK CONNECT TERMINALS, EXCEPT HN61KR901, 911, 913 SUPPLIED WITH QUICK CONNECT TERMINAL KIT
CONTACT ARRANGEMENT DIAGRAMS:
(1)
SPST
(4)
DPST
2-1/4″″″″H x 2-1/4″″″″W x 2-7/16″″″″D
P257
286
TOTALINE® RELAYS/ACCESSORIESPOWER DUTY RELAYS
RELAYS WITH ENCLOSURE
* SELF-CONTAINED TO FACILITATE REMOTE MOUNTING* LEAD WIRES ARE COLOR CODED* READY FOR DIRECT MOUNTING TO ANY 1/2″ STANDARD ELECTRICAL KNOCKOUTCONTACT ARRANGEMENT DIAGRAMS:
(1)(3)
SPST
SPDT
*See contact arrangement diagrams.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
120 V 240 V 120 V 240 V18 18 18 18 24 SPST 1 HN61KS10118 18 18 18 24 SPDT 3 HN61KJ310- - - 25 120 SPST 1 HN61KB200
18 18 18 18 120 SPDT 3 HN61KJ32018 18 18 18 240 SPDT 3 HN61KJ330
P258
* PANEL MOUNTED POWER DUTY RELAY* NEMA TYPE I ENCLOSURE* SCREW TERMINALS* MAY BE MOUNTED IN ANY POSITION EXCEPT RELAY TERMINALS FACING DOWNCONTACT ARRANGEMENT DIAGRAM:
(4)
DPST
*See contact arrangement diagram.
CONTACT RATING (FLA)COIL
VOLTSCONTACT
ARRANGEMENT*DIAGRAM P/NINDUCTIVE RESISTIVE
0-600V 0-600V16 16 120 DPST 4 HN61AJ10116 16 240 DPST 4 HN61AJ108
5-3/4″″″″H x 3-1/2″″″″W x 3-1/4″″″″D
P259
* EMERGENCY HEAT PILOT DUTY RELAY* RELAYS -
ONE TPST RELAY N.O.ONE DPST RELAY, 1 POLE N.O., 1 POLE N.C.
* SUITABLE FOR INDOOR APPLICATION* SCREW TERMINALS* INDUCTIVE CONTACT RATING: 3A @ 24 V; 125 VA @ 120/240 V* HOLDING COIL: 24 V, 6 VA
P/N: HN65DZ026
5-1/4″″″″H x 4-1/4″″″″W x 3.0″″″″DP260
287
TOTALINE® RELAYS/ACCESSORIES
TOTALINE FAN CONTROL CENTER RELAYS
*See contact arrangement diagrams.
CONTACTARRANGEMENT*
DIAGRAMTRANSFORMER
PRIMARYPLUG-INRELAY
P/N
DPDT 7 120/208/240 Semi-Enclosed P211-4010SPNO/SPNC 4 120 Semi-Enclosed P211-4012
SPDT 3 120 Semi-Enclosed P211-4013SPST 1 120 Semi-Enclosed P211-4014SPDT 3 240 Semi-Enclosed P211-4015SPDT 3 120 Semi-Enclosed P211-4020
• 40 VA TRANSFORMER
• 24 VOLT SECONDARY
• FITS STANDARD 4 IN. JUNCTION BOX
• SELF-CONTAINED UNIT REQUIRED NO ADDITIONAL ENCLOSURE
• UNIT IMPRINTED WITH WIRING DIAGRAM
RESISTIVE CONTACT RATING: 15A @ 277 V
INDUCTIVE CONTACT RATING: 3/4 H.P., 12A @ 120 V; 3/4 H.P., 6A @ 240 V
RELAY COIL VOLTS: 24
CONTACT ARRANGEMENT DIAGRAMS:
(1) (3)(7)
SPST
SPDT
DPDTP261
288
CONTACTORS
TOTALINE CONTACTORS
POLE AMPS TERMINAL TYPE COIL VACAUX
CONTACTLENGTHin. (cm)
HEIGHTin. (cm)
P/N
SINGLE POLE 30 (SCREW TERM. & SHUNT) 24 3.3 (8.38) 2.3 (5.84) P282-0311SINGLE POLE 30 (SCREW TERM. & SHUNT) 120 3.3 (8.38) 2.3 (5.84) P282-0312SINGLE POLE 30 (SCREW TERM. & SHUNT) 208/240 3.3 (8.38) 2.3 (5.84) P282-0313
TWO POLE 30 (SCREW TERMINALS) 24 3.3 (8.38) 2.5 (6.35) P282-0321TWO POLE 30 (SCREW TERMINALS) 120 3.3 (8.38) 2.5 (6.35) P282-0322TWO POLE 30 (SCREW TERMINALS) 208/240 3.3 (8.38) 2.5 (6.35) P282-0323TWO POLE 40 (LUG TERMINALS) 24 3.3 (8.38) 2.6 (6.60) P282-0421TWO POLE 40 (LUG TERMINALS) 120 3.3 (8.38) 2.6 (6.60) P282-0422TWO POLE 40 (LUG TERMINALS) 208/240 3.3 (8.38) 2.6 (6.60)- P282-0423
THREE POLE 30 (SCREW TERMINALS) 24 P282-X34220 3.4 (8.64) 2.6 (6.60) P282-0331THREE POLE 30 (SCREW TERMINALS) 24 P282-X98220 3.4 (8.64) 2.6 (6.60) P282-0331ATHREE POLE 30 (SCREW TERMINALS) 120 P282-X34220 3.4 (8.64) 2.6 (6.60) P282-0332THREE POLE 30 (SCREW TERMINALS) 120 P282-X98220 3.4 (8.64) 2.6 (6.60) P282-0332ATHREE POLE 30 (SCREW TERMINALS) 208/240 P282-X34220 3.4 (8.64) 2.6 (6.60) P282-0333THREE POLE 30 (SCREW TERMINALS) 208/240 P282-X98220 3.4 (8.64) 2.6 (6.60) P282-0333ATHREE POLE 40 (LUG TERMINALS) 24 P282-X34220 3.4 (8.64) 2.6 (6.60) P282-0431THREE POLE 40 (LUG TERMINALS) 24 P282-X98220 3.4 (8.64) 2.6 (6.60) P282-0431ATHREE POLE 40 (LUG TERMINALS) 120 P282-X34220 3.4 (8.64) 2.6 (6.60) P282-0432THREE POLE 40 (LUG TERMINALS) 120 P282-X98220 3.4 (8.64) 2.6 (6.60) P282-0432ATHREE POLE 40 (LUG TERMINALS) 208/240 P282-X34220 3.4 (8.64) 2.6 (6.60) P282-0433THREE POLE 40 (LUG TERMINALS) 208/240 P282-X98220 3.4 (8.64) 2.6 (6.60) P282-0433ATHREE POLE 50 (LUG TERMINALS) 24 P282-X34300 4.2 (10.67) 3.6 (9.14) P282-0531THREE POLE 50 (LUG TERMINALS) 120 P282-X34300 4.2 (10.67) 3.6 (9.14) P282-0532THREE POLE 50 (LUG TERMINALS) 208/240 P282-X34300 4.2 (10.67) 3.6 (9.14) P282-0533THREE POLE 60 (LUG TERMINALS) 24 P282-X34300 4.2 (10.67) 3.6 (9.14) P282-0631THREE POLE 60 (LUG TERMINALS) 120 P282-X34300 4.2 (10.67) 3.6 (9.14) P282-0632THREE POLE 60 (LUG TERMINALS) 208/240 P282-X34300 4.2 (10.67) 3.6 (9.14) P282-0633THREE POLE 75 (LUG TERMINALS) 24 P282-X34300 5.0 4.06 P282-0731THREE POLE 75 (LUG TERMINALS) 120 P282-X34300 5.0 4.06 P282-0732THREE POLE 75 (LUG TERMINALS) 208/240 P282-X34300 5.0 4.06 P282-0733THREE POLE 90 (LUG TERMINALS) 24 P282-X34300 5.0 4.06 P282-0931THREE POLE 90 (LUG TERMINALS) 120 P282-X34300 5.0 4.06 P282-0932THREE POLE 90 (LUG TERMINALS) 208/240 P282-X34300 5.0 4.06 P282-0933
Covers:
Standard on 40 amp and larger.Mounting:
Panel mount and straight thru wiring.Application:
Designed for use in residential and commercial refrigeration, air con-ditioning, and heating applications.Also: • 'Water pump motors
• Blower or fans• Compressor motors• Resistance heating and other similar applications.
UL / CSA recognized
Design Construction:
50/60 HzMeets specifications for devices up to 600 VAC in accordance with U/L bulletin no. 508 "Industrial Control Equipment'
Coil Insulation:
Standard Class B insulation.Terminals:
Power #10-32 combination hex washer head screw, #10-32 combination hex head with pressure plate or box lug for 4 - 14 CU/AL wire.
Quick Connects - (2) 0.250 male push-ons available on each pole.Coil - (2) 0.250 male push-ons.
P274A P275 P276AP273
289
CONTACTORSSINGLE POLE CONTACTOR
TWO POLE CONTACTOR
THREE POLE CONTACTOR
• STRAIGHT THROUGH, TOP WIRING
• SCREW POWER TERMINALS
• 50/60 HZ
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240-277 25 A. 125 A. 25 A.
24 HN51KB024480 10 A. 50 A. 25 A.600 8 A. 40 A. 25 A.
240-277 30 A. 150 A. 40 A.24 HN51KC024480 15 A. 75 A. 40 A.
600 12.5 A. 50 A. 40 A.P265
• STRAIGHT THROUGH, TOP WIRING
• SCREW POWER TERMINALS
• 50/60 Hz
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240 25 A. 150 A. 30 A.
460 HN52LB244480 25 A. 125 A. 30 A.600 25 A. 100 A. 20 A.240 30 A. 150 A. 35 A. 24 HN52KC024480 21 A. 125 A. 35 A. 120 HN52KC052600 17 A. 100 A. 35 A. 208/240 HN52KC053277 — — 50 A.
24 HN52SA033480 — — 50 A.600 — — 50 A.240 40 A. 240 A. 50 A.
24 HN52KD024480 40 A. 200 A. 50 A.600 40 A. 160 A. 50 A.
P266
• STRAIGHT THROUGH, TOP WIRING
• QUICK CONNECT TERMINALS
• 50/60 HZ
• SCREW TERMINALS
• 50/60 HZ
*Has Aux. Contacts (1) N.O., (1) N.C., rated 3A, @ 115-600 volts.
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240 25 A. 150 A. 30 A.
24 HN53JN001480 25 A. 125 A. 30 A.600 25 A. 100 A. 30 A.240 40 A. 240 A. 50 A.
24 HN53CD025480 40 A. 200 A. 50 A.600 40 A. 160 A. 50 A.
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240 40 A. 240 A. 50 A.
1202080240
HN53AB252*HN53AB251*
480 25 A. 115 A. 25 A.600 25 A. 105 A. 25 A.
P268
P267
290
CONTACTORSTHREE POLE CONTACTOR
FOUR POLE CONTACTOR
• PRESSURE LUG TERMINALS
• SCREW TERMINALS
*Has Aux. Contacts (1) N.O., (1) N.C., rated 3A, @ 115-600 volts.**Has Aux. Contacts (1) N.O., (1) N.C. rated 10A. @ 0-600 volts.
**Has Aux. Contacts (1) N.O., (1) N.C. rated 10A. @ 0-600 volts.
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240 40 A. 240 A. 50 A. 24 HN53CD025480 40 A. 200 A. 50 A. 115 HN53CD116600 40 A. 160 A. 50 A. 208-240 HN53CD209
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240 40 A. 240 A. 40 A. 120
HN53AD431*480 40 A. 160 A. 40 A.600 40 A. 140 A. 40 A.
24 HN53CD024240 40 A. 240 A. 50 A. 115 HN53CD115480 40 A. 200 A. 50 A. 208-240 HN53CD208600 40 A. 160 A. 50 A. 208-240 HN53CD231**
480 HN53CD480240 25 A 150 A 35 A
HN53CB115HN53CB208
480 25 A 125 A 35 A 115600 25 A 100 A 35 A 208-240
LINE VOLTS
FULL LOAD LOCK ROTOR RESISTIVECOIL
VOLTAGETERMINALS P/N
240 60 A. 360 A. 75 A. 115 SCREW HN53HF122480 60 A. 300 A. 75 A. 115 LUG HN53HF115**600 60 A. 240 A. 75 A. 208-240 SCREW HN53HF208
208-240 LUG HN53HF207**240 75 A. 450 A. 90 A. 115 SCREW HN53HG120480 75 A. 375 A. 90 A. 115 SCREW HN53HG121**600 75 A. 300 A. 90 A. 208-240 SCREW HN53HG240240 90 A. 540 A. 90 A.
120208-240
SCREWSCREW
HN53HH210**HN53HH260**
480 90 A. 450 A. 90 A.600 90 A. 360 A. 90 A.240 120 A. 720 A. —
115208-240
LUGLUG
HN53HJ115HN53HJ220
480 120 A. 600 A. —600 120 A. 480 A. —
P269
P270
P271
• STRAIGHT THROUGH, TOP WIRING
• 50/60 HZ
• PRESSURE LUG CONNECTOR - HN54680001
LINE VOLTS FULL LOAD LOCK ROTOR RESISTIVE COIL VOLTAGE P/N240 40 A. 240 A. 50 A.
24 HN54680001480 40 A. 200 A. 50 A.600 40 A. 160 A. 50 A.
P272
291
TRANSFORMERS
TOTALINE CONTROL TRANSFORMERS
CONTROL TRANSFORMERS
• FOR LOW AND MEDIUM VA REQUIREMENTS
• USE TO STEP DOWN VOLTAGE FOR CONTROL CIRCUITS
• LARGE SELECTION OF RATINGS AND MOUNTING
*Supplied with 9 inch leads.
FIG. VA RATING PRIMARY VOLTS HZ SECONDARY VOLTS P/NA 20 120 50/60 24 P201-2201*A 40 120/208/240 50/60 24 P201-3401*C 40 120/208/240 50/60 27/12/2.5 P201-3402*C 40 120/208/240 50/60 24 P201-3403*C 50 120/2081240 50/60 12/24 P201-35150*B 75 120/208/240/480 50/60 24 P201-4701B 100 120/208/240/480 50/60 24 P201-4901
FIGURE #A FIGURE #B FIGURE #C
P277 P278 P279
*Transformer has leads on primary side.**Transformer has leads on primary and secondary sides.
4x4 Conduit box mount (4 inch x 4 inch).2x4 Conduit box mount (2 inch x 4 inch).LAM Lamination mount.
FIG. VA RATINGPRIMARY
VOLTSHZ
SECONDARYVOLTS
DIMENSIONS (in.)P/N
LENGTH WIDTH HEIGHTA 20 240 60 25 2 3-11/16 2 HT01AA140A 30 115 50/60 24 3-3/8 1-7/8 2-5/16 HT01BB116B 30 265 60 24 3-1/4 1-3/4 2 HT01BB265*
2x4 40 120 - 24 - - - HT680004*A 40 208 - 24 - - - HT680005*A 40 120 60 12/24 2-7/8 2 2-3/8 HT01CN001A 40 120 60 24 3 2-9/16 2 HT01BC116A 40 115/230 50/60 25 3-11/16 2-3/8 2-1/4 HT01AX220B 40 200/230/460 50/60 24 4 2-3/4 2-5/8 HT01BD201*A 40 230 50/60 12/24 2-15/16 2-7/16 2-3/16 HT01BB231*A 45 115/230 50/60 12.5 4 2-13/16 2-9/16 HT01BD117B 48 460 60 25 3 2-1/2 2-13/16 HT01CZ460A 60 200/230 60 24 4 2-3/8 2-19/32 HT01AW230A 60 115/208/230 50/60 24 4 2-5/8 2-9116 HT01AW229A 60 208/230/460 50/60 24 4 2-5/8 2-9/16 HT01AW234A 60 115 50/60 24 4 3.0 2-9/16 HT01BB118
LAM 60 240 60 24 3 2-1/4 2-1/2 HT01AZ240**B 75 200/230/460 60 24 4 2-3/4 2-5/8 HT01BD236*B 75 200/230/460 50 24 3-7/16 3-1/8 3-3/4 HT01BB201*A 5/25 240 50 24/24 3-23/32 2-1/8 2-1/4 HT01BC232A 1- 208/230/265 50/60 24 3-1/4 1-29/32 2 HT01CN002*
• FOR LOW AND MEDIUM VA REQUIREMENTS
• USE TO STEP DOWN VOLTAGE FOR CONTROL CIRCUITS
• LARGE SELECTION OF RATINGS AND MOUNTING
FIGURE #A FIGURE #BP278P277
292
TRANSFORMERS
POWER TRANSFORMERS
• USE TO STEP DOWN VOLTAGE FOR CONTROLS
• LARGE SELECTION OF RATINGS
• FOR CONTROL BOX MOUNTING
VA RATINGPRIMARY
VOLTSHZ
SECONDARYVOLTS
DIMENSIONS (in.)P/N
LENGTH WIDTH HEIGHT50 240/480 60 120 3-1/4 3 2-1/2 HT01BZ050
100 460/575 60 115 3-13/16 4-3/8 3-3/16 HT01BB100100 440/550 50/60 220 4-3/8 3-3/4 3-3/16 HT01BE100150 230/460 50/60 115 4-3/4 3-3/4 3-3/16 HT01BZ150150 240/480 60 120/240 3-3/4 4 3-3/8 HT01AH150150 575 60 115 4-3/4 3-3/4 3-3/16 HT01BZ155200 440/550 50/60 220 4-7/8 4-1/2 3-7/8 HT01BE200200 575 60 115 4-1/2 3-3/16 4-1/2 HT01BZ205250 230/460 60 115 5 4-1/2 3-13/16 HT01BZ250250 440/550 60 220 5-7/8 5-1/4 4-1/2 HT01BE250350 230/460 60 115 6 4-1/2 3-13/16 HT01BZ350
350208/230460/575
60 115 6-1/4 5-1/4 4-5/8 HT01BE235
350 575 60 115 4-1/2 3-3/16 6 HT01BZ351
750208/230460/575
60 115 8-7/8 5-1/4 4-5/8 HT01BE236
• FOR LOW VA REQUIREMENTS
• TAKES MINIMUM OF SPACE
• EASILY MOUNTED AND WIRED
VA RATINGPRIMARY
VOLTSHZ
SECONDARYVOLTS
DIMENSIONS (in.)P/N
LENGTH WIDTH HEIGHT40 208/230 60 115 3-11/16 2-3/4 2-5/16 HT01BC20848 460 50/60 230 4-1/26 2-5/8 2-11/16 HT01BD461
P282
P283
293
TRANSFORMERS
POWER TRANSFORMERS
• EASILY WIRED
• OPEN FRAME REQUIRES LESS SPACE
• FOR CONTROL BOX APPLICATIONS
VA RATINGPRIMARY
VOLTSHZ
SECONDARYVOLTS
DIMENSIONS (in.)P/N
LENGTH WIDTH HEIGHT50 460/575 60 230 4-1/8 3-3/16 3-3/16 HT01BE220
100 200/230/460 50/60 115 4-7/8 3-15116 3-7/8 HT01BE208200 200/230/460 50/60 115 5-5/8 3-15/16 3-7/8 HT01BE210250 460 60 230 5-5/8 3-15/16 3-7/8 HT01BE222350 200/230/460 50/60 115 6-1/2 4-3/4 4 HT01BE218350 460 50/60 230 5-5/8 3-15/16 3-7/8 HT01BE223350 575 60 230 5-5/8 3-15/16 3-7/8 HT01BE225500 200/230/460 50/60 115 6-1/2 5-1/2 4-5/8 HT01BE219500 575 50/60 115 6-1/2 4-3/4 4 HT01BE221650 200/230/460 50/60 115 6-1/2 5-1/2 4-5/8 HT01BE224750 200/230/460 50/60 115 7-1/4 5-1/2 4-5/8 HT01BE227750 575 50/60 115 7-1/4 5-1/2 4-5/8 HT01BE228
VA RATINGPRIMARY
VOLTSHZ
SECONDARYVOLTS
DIMENSIONS (in.)P/N
LENGTH WIDTH HEIGHT50 240/480 60 120/240 6-1/4 3-1/8 2-7/8 HT01AH863
100 240/480 60 120/240 6-3/8 5-1/8 3-1/4 HT01AH857500 240/480 50/60 120/240 9-3/4 4-13/32 4-3/32 HT01AC459750 240/480 60 120/240 9-5/8 7-7/8 5-1/2 HT01AH850750 600 60 120/240 10-9/16 4-7/8 4-5/8 HT01AH856
1000 240/480 60 120/240 11-3/8 5-5/8 5-1/4 HT01AH8511000 600 60 120/240 11-3/8 5-5/8 5-1/4 HT01AH8591500 240/480 60 120/240 12-1/2 5-5/8 5-1/4 HT01AH8622000 240/480 60 120/240 13-7/8 5-5/8 5-1/4 HT01AH8522000 600 60 120/240 13-7/8 5-5/8 5-1/4 HT01AH8543000 240/480 60 120/240 12-3/4 7-27/32 7-5/16 HT01AH8533000 600 60 120/240 13-1/8 9-3/8 6-3/4 HT01AH855
• ENCLOSED WIRING
• EASILY MOUNTED ON PANEL OR EQUIPMENT
• 4 KNOCKOUTS FOR CONDUIT CONNECTION
POWER TRANSFORMERS
P284
P285