8
Doc No. FM5575 issue A Page 1 Touchsafe® Pro Wireless Nursecall System _________________________________________________________________________________________________ Accessory Leads Installation Guide Aidcall operates a policy of continual product improvement and reserves the right to modify the specification of its products. If any variation to the details in this document are suspected please contact Aidcall’s Technical Support. Aidcall, a business unit of Legrand Electric Ltd Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF. T: +44 (0) 1670 357 431 www.aidcall.co.uk ________________________________________________________________

Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 1   

Touchsafe® Pro Wireless Nursecall System _________________________________________________________________________________________________ 

     

Accessory Leads Installation Guide 

                          

Aidcall operates a policy of continual product improvement and reserves the right to modify the specification of its products.   

If any variation to the details in this document are suspected please contact Aidcall’s Technical Support.

           

Aidcall, a business unit of Legrand Electric Ltd Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.  T: +44 (0) 1670 357 431   www.aidcall.co.uk  ________________________________________________________________ 

Page 2: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 2   

 

CONTENTS   

Section  Topic  Page      

1  Product Overview  2 

2  Important Safety Instructions 3 

3  Regulatory Information  3 

4  Maintenance & Care  3 

5  Accessory Lead Options  4 

6  Installation 5 

7  Programming  6 

8  Nursecall Panel Display  7 

9  Specification  8 

  

ENTS 

1.  PRODUCT OVERVIEW  Accessory Leads are used to connect other manufacturer’s equipment to the Touchsafe Pro Call Point to customise the Nursecall system for specific patient needs.   

Accessory Leads are simply plugged‐in to the right‐hand socket on the lower face of the Touchsafe Pro Call Point, the leads are available with a range of plugs/sockets to fit most common switches and sensors.   

Accessory Leads can be supplied to display the event type on the Nursecall panel as “Call”, “Assistance” or 

“Emergency”. Alternatively the Touchsafe Pro Call Point can be re‐programmed to display the most 

appropriate event type regardless of the lead supplied ‐ see Section 7 for details. 

  

   

Any third party equipment connected to a Touchsafe Pro Call Point via an Accessory Lead must have a voltage free, normally open clean contact output which closes on alarm.  

                     

Page 3: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 3   

 

2.  IMPORTANT SAFETY INSTRUCTIONS   

Read and understand these instructions before use. Keep these instructions for future reference. 

Setup and test the accessories following these instructions. 

 

Do not attempt to disassemble this product.  

 

   

Accessory Leads should only be plugged into Aidcall Call Points. Under no circumstances should they be plugged into any other manufacturer’s equipment.  

 Do not submerge the lead (or equipment) in water. 

 

Clean with a hard‐surface disinfectant wipe or a damp cloth and a non‐abrasive cleaning product.  Polish with a dry duster.  

 

  

Avoid using harsh, abrasive or corrosive cleaning agents or detergents (e.g. scouring powders, bleaches, polishes, etc.) when cleaning this product. 

 

  

At the end of its life this product should be disposed of and recycled in accordance with the environmental regulations. See the Regulatory Information in section 3 below. 

  CONTENTS 

3.  REGULATORY INFORMATION   

 

This symbol on the product indicates it complies with all relevant EU Directives as required by law. Safety of Information Technology Equipment; EN 60950‐1:2006+A12:2011 Electro Magnetic Compatibility; EMC 2004/108/EC Restriction of Hazardous Substances; RoHS 2011/65/EU A copy of the complete Declaration of Conformity is available from Aidcall.  

 

This symbol on the product indicates it is classed as Electrical or Electronic Equipment and should not be disposed of with other commercial waste at the end of its working life.  

The Waste of Electrical and Electronic Equipment (WEEE) Directive (2012/19/EU) has been put in place to recycle products using the best available recovery and recycling techniques to minimise impact on the environment, treat hazardous substances and avoid increasing landfill.  

For product disposal please contact your supplier and check the terms and conditions of the purchase contract and ensure this product is not mixed with other commercial waste for disposal.   

  NTENTS 

4.  MAINTENANCE & CARE  Accessory Leads should be regularly cleaned with anti‐bacterial wipes, at the same time they should be checked for signs of external physical damage. Broken cables or connectors can trap dirt and contribute to the spread of germs. Any Accessory Leads found damaged should be replaced immediately.        

Page 4: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 4   

 

5.  ACCESSORY LEAD OPTIONS   

 

 

 

 

 

 

 

 

 

 

 

OPTIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

All Accessory Leads are 2 metres long and have a 6 pin RJ11 data plug on one end for connection to the right hand side accessory socket on the lower face of the Touchsafe Pro Call Point.  

Leads can be supplied un‐terminated for direct connection to other manufacturer’s equipment or factory fitted with a range of different plugs and sockets;   

Plug Accessory Leads intothe Touchsafe Pro Call Point right hand side socket 

8 Pin RJ45Plug 

ZNC259

6 Pin RJ11 Plug 

Un‐terminated 

*Notes    1. The ZNC249 Lead is only suitable for an Aidcall Sensor Controller   2. The ZNC259 Lead is only suitable for an Emfit Epilepsy Monitor   

  Both these products can work wirelessly if Telecare Receivers (TCR’s)    are installed.  

3.5mm Jack Plug 

3.5mm Jack Socket 

6.35mm Jack Plug 

6.35mm Jack Socket 

6 Pin RJ11 Plug 

ZNC247

ZNC249

ZNC245ZNC253ZNC257 

ZNC246ZNC254ZNC258 

ZNC244ZNC252ZNC256 

ZNC220ZNC221ZNC222 

Part No.  Lead Type Default Event Type 

 

ZNC247  Accessory Lead (Un‐terminated)  All 

ZNC245  Accessory Lead with 3.5mm Jack Plug  Call 

ZNC253  Accessory Lead with 3.5mm Jack Plug Emergency

ZNC257  Accessory Lead with 3.5mm Jack Plug  Assistance  

ZNC246  Accessory Lead with 3.5mm Jack Socket Call

ZNC254  Accessory Lead with 3.5mm Jack Socket  Emergency 

ZNC258  Accessory Lead with 3.5mm Jack Socket  Assistance  

ZNC244  Accessory Lead with 6.35mm Jack Plug  Call 

ZNC252  Accessory Lead with 6.35mm Jack Plug  Emergency 

ZNC256  Accessory Lead with 6.35mm Jack Plug Assistance 

ZNC220  Accessory Lead with 6.35mm Jack Socket  Call 

ZNC221  Accessory Lead with 6.35mm Jack Socket Emergency

ZNC222  Accessory Lead with 6.35mm Jack Socket  Assistance  

ZNC249  Accessory Lead with RJ11 Plug*1  Call

ZNC259  Accessory Lead with RJ45 Plug*2  Emergency

Page 5: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 5   

 

ZNC247 Unterminated Accessory Lead  

   

RJ11 Pin No.  Wire Colour Function Default Event Type   

1  Blue Input 1 Call

2  Yellow Input 2 Assistance

3  Green Common ‐

4  Red Input 3 Tamper

5  Black Input 4 Emergency

6  White Input 5 Cancel

 

6. INSTALLATION  Simply plug the Accessory Lead into the right‐hand socket on the lower face of the Touchsafe Pro Call Point. The plug only goes in one way and it will click into place when inserted correctly.  

Note: the Call Point has 2 sockets on the lower face; the left hand socket is for an optional Pear Push.                UN‐TERMINATED ACCESSORY LEAD    

 

 

The un‐terminated Accessory Lead can be used to connect accessories with screw connectors or for fitting a 

custom connector on‐site. Remember all accessories must have a voltage‐free N/O clean contact output.  

5 different default event types are available by connecting different wire colours, if necessary these can be 

changed in programming – see Section 7. 

             OPTIONAL TAMPER CONNECTION  

Connect the Green and Red wires (RJ11 pins 3 & 4) together for the “Common” and choose the Blue, Yellow or Black wire for the N/O input (depending on the event type required).  

If the Accessory Lead is un‐plugged from the Touchsafe Pro Call Point then a “Tamper Alert” will be displayed on the Nursecall panel – see Section 8.      

Left Hand Pear Push Socket (RJ45)Plug the Accessory Lead  into the Right Hand  Accessory Socket (RJ11) 

Plug the other end of the lead into the relevant accessory 

Touchsafe Pro Call Point (viewed from below) 

Page 6: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 6   

 

7. PROGRAMMING 

Programming is not necessary for default event types i.e. Call, Emergency or Assistance. If required, the 

Touchsafe Pro Call Point can have its hardwired input(s) changed to report different event types on the 

Nursecall panel. In programming mode the Call Point buttons have the following functions; 

 

 

 

 

 

 

  

 

 

PROGRAM HARDWIRED INPUT 1  

1. Open the battery compartment and remove one of the batteries from the Call Point 

2. Hold down the ORANGE button and refit the battery 

3. Release the ORANGE button; the LED will slowly FLASH GREEN and the unit will beep twice to confirm  

    you are in Program Mode. If the unit has a display it will show “Program PAN ID”. 

4. Press the ORANGE button five times to skip other options until the display shows “Program Input 1”. 

5. Enter the required Event Code as per the table below by using the LIGHT GREY button for HUNDREDS, 

     the DARK GREY button for TENS and the GREEN button for UNITS e.g. for an “Emergency” event you 

     would press the GREEN button three times.  

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Press the ORANGE button to confirm; the LED will continue to FLASH AMBER but at a faster pace and if  

    the unit has a display it will show “Program Input 2”.  

7. Repeat for input 2 or press the ORANGE button four times to skip inputs 2‐5 if not required. 

8. The unit will beep three times and exit Program Mode.  

 If no keys are pressed for 10 seconds the unit will reset out of Program Mode 

Orange = Enter 

Green = Units Light Grey = Hundreds 

LED Indicator

Dark Grey = Tens

Event Type  Event Code Event Type Event Code  

Call (input 1 default)  1  Epilepsy 36 

Assistance (input 2 default)  2  Bathroom Occupancy 37 

Emergency (input 4 default)  3  Chair Occupancy 38 

Cardiac  4  High Temperature 41 

Nurse Present  5  Low Temperature 42 

Help  6  Smoke 43 

Pull Cord  12 Natural Gas 44 

Cancel (input 5 default)  14 Fire 46 

Tamper (input 3 default)  15 Heat 48 

Pear Push Lead Call 1/2  17/18 Carbon Monoxide 49 

Accessory Call  19 Intruder 50 

Inactivity  30 Flood 80 

Pill Dispenser  31 Doorbell 83 

Enuresis  32 Medication 84 

Bed Occupancy 33 WC 139 

Client Wander 1/2  34/35

Page 7: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 7   

 

8. NURSECALL PANEL DISPLAY  For example; if an Enuresis sensor is connected to the Accessory Lead and the Event Type “32” is setup in the Call Point then an alarm will be displayed on the Touchsafe Pro Nursecall panel like this…      

The screen banner is yellow for an Enuresis Alarm. Touch the banner to display Client Notes. Press the Accept button on the banner to silence the alarm  and notify all other panels the call is being dealt with. The screen banner changes to purple when a call is accepted.   

   If an Accepted call is not cancelled within the preset time it will revert to an active call.   

TO CANCEL THE CALL          If the unit has a display it will first show “CALLING ‐ CANCEL” then “ACKNOWLEDGED” when the call has been received and cancelled off the Nursecall panel.  

If there is another call waiting (within the same Zone) the details will be displayed, if more than one call is waiting the one with highest priority will be displayed.   

ACCESSORY LEAD TAMPER ALERT  

When an Accessory Lead is removed from a Call Point  the Nursecall panel will display the following…      

The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press the Accept button on the banner to silence the alarm  and notify all other panels the call is being dealt with. The screen banner changes to purple when a call is accepted. Press the LIGHT GREY button on the Call Point to cancel the call.  

Note: Call Point Tamper alerts can be disabled in the panel setup    

CALLINGCANCEL HC. 345  ID. 001

Press the LIGHT GREY button on the Call Point to cancel the call 

Page 8: Touchsafe Pro Wireless Nursecall · the Nursecall panel will display the following… The screen banner is grey for a Tamper alert. Touch the banner to display Client Notes. Press

Doc No. FM5575 issue A Page 8   

 

9. SPECIFICATION  

Un‐Terminated Accessory Lead   Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  None 

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres 

Aidcall Part No./Default Event Types  ZNC247 = Call, Assistance, Tamper, Emergency or Cancel 

 

Accessory Leads with 3.5mm Jack Plug Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  2 Pole 3.5mm Mono RCA Phono Jack Plug 

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres 

Aidcall Part No’s/Default Event Types  3 No: ZNC245 = Call, ZNC253 = Emergency & ZNC257 = Assistance

 

Accessory Leads with 3.5mm Jack Socket  Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  2 Pole 3.5mm Mono Line Jack Socket

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres 

Aidcall Part No’s/Default Event Types  3 No: ZNC246 = Call, ZNC254 = Emergency & ZNC258 = Assistance

   

Accessory Leads with 6.35mm Jack Plug Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  2 Pole 6.35mm Mono RCA Phono Jack Plug 

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres 

Aidcall Part No’s/Default Event Types  3 No: ZNC244 = Call, ZNC252 = Emergency & ZNC256 = Assistance

   

Accessory Leads with 6.35mm Jack Socket Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  2 Pole 6.35mm Mono Line Jack Socket

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres 

Aidcall Part No’s/Default Event Types  3 No: ZNC220 = Call, ZNC221 = Emergency & ZNC222 = Assistance

 

Accessory Lead for Aidcall Sensor Controller Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  6/6 RJ11 Data Plug

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres 

Aidcall Part No./Default Event Type  ZNC249 = Call 

 

Accessory Lead for Emfit Epilepsy Monitor Call Point Connector Type  6/6 RJ11 Data Plug

Accessory Connector Type  RJ45 Data Plug

Cable Type  6 Core FCC‐68 7/0.16mm (26 AWG) – Light Grey 

Cable Length  2 metres

Aidcall Part No./Default Event Type  ZNC259 = Emergency