2470 MILLTOWER COURT, MISSISSAUGA, ONTARIO L5N 7W5 PHONE: (905) 363-0678 FAX: (905) 363-0681
ENVIRONMENTAL HEALTH & SAFETY MANAGEMENT SERVICES FROM OFFICES ACROSS CANADA
www.pinchin.com 1-888-767-3330
Toxics Substance Reduction Plan Summary
For
Particulate Matter PM10 (CAS # NA-M09)
Ensyn Technologies Inc.
1 Innovation Drive
Renfrew, Ontario
K7V 4B1
Prepared for:
Matt Gibbon
GM of Operations
December 19, 2013
Pinchin File: 89489
Copyright © 2013 by Pinchin Environmental Ltd.
Toxics Substance Reduction Plan Summary – Particulate Matter PM10 (CAS # NA-M09)
1 Innovation Drive, Renfrew, ON December 19, 2013
Ensyn Technologies Inc. Pinchin File: 89489
© 2013 Pinchin Environmental Ltd. Page ii
EXECUTIVE SUMMARY
Pinchin Environmental Ltd. (Pinchin) evaluated Ontario Regulation 455/09, of the Toxics
Reduction Act as it applies to the facility Ensyn Technologies Inc. (Ensyn) located in Renfrew,
Ontario. Ensyn is a world leader for the production of renewable liquids from the thermal
conversion of biomass material using their proprietary Rapid Thermal Processing Technology
(RTPTM
).
Products generated from the liquids depend on the specific feedstock being processed but can
include: specialty chemicals (food flavorings, pharmaceuticals), binders (adhesives, road
stabilizers), preservatives, road de-icers and co-polymers (structural foams, plastics). The char
by-product can be further processed to yield quality activated carbon for applications like
wastewater treatment.
The liquids are also suitable as a direct substitute for fossil fuels in a wide range of applications.
They can be direct-fired in boilers/combustors/kilns as well as used to fuel large stationary diesel
engines and gas turbines for co-generation of electricity. These liquids can also be used to
produce transportation fuels. (Diesel, Gasoline and Jet fuel)
Their processes include raw material receiving, sorting and sizing, thermal conversion and
condensation, combustion, product/by-product storage and shipping. Ensyn reported to the 2012
National Pollutant Release Inventory and to the Ministry of Ontario Toxics Reduction Act under
O. Regulation 455/09 for Particulate Matter PM10 and is required to prepare a Toxics Reduction
Plan.
Toxics Substance Reduction Plan Summary – Particulate Matter PM10 (CAS # NA-M09)
1 Innovation Drive, Renfrew, ON December 19, 2013
Ensyn Technologies Inc. Pinchin File: 89489
© 2013 Pinchin Environmental Ltd. Page iii
TABLE OF CONTENTS
EXECUTIVE SUMMARY ...............................................................................................................II
1.0 BASIC FACILITY INFORMATION....................................................................................1
2.0 STATEMENT OF INTENT ..................................................................................................2
3.0 SUBSTANCES REQUIRING PLANS .................................................................................2
4.0 OBJECTIVES OF THE PLAN & ANY TARGETS .............................................................2
5.0 OPTIONS TO BE IMPLEMENTED (OR STATEMENT THAT NONE ARE TO BE
IMPLEMENTED)..............................................................................................................................2
6.0 CONTENTS OF THIS PLAN SUMMARY REFLECTS PLAN .........................................3
7.0 CERTIFICATION BY HIGHEST RANKING EMPLOYEE ...............................................4
8.0 CERTIFICATION BY LICENSED PLANNER ...................................................................5
Toxics Substance Reduction Plan Summary – Particulate Matter PM10 (CAS # NA-M09)
1 Innovation Drive, Renfrew, ON December 19, 2013
Ensyn Technologies Inc. Pinchin File: 89489
© 2013 Pinchin Environmental Ltd. Page 1
1.0 BASIC FACILITY INFORMATION
Substance Information
Name Particulate Matter PM10
CAS # NA-M09
Facility Information
Company Name Ensyn Technologies Inc.
Facility Name same
Facility Address 1 Innovation Drive, Renfrew, Ontario K7V 4B1
Site Coordinates (main
entrance of site) 371051 E, 5037487 N; Zone 18
NPRI ID 11755
MOE ID N/A
Number of Full-Time
Employees in 2012 14
2-Digit NAICS Code 31 - Manufacturing
4-Digit NAICS Code 3119 – Other Food Manufacturing
6-Digit NAICS Code 311930 – Flavouring Syrup and Concentrate Manufacturing
Business Number 130742232
Facility Contact Information
Public Contact Matt Gibbon
GM of Operations
Phone #: (613) 433-9508 x27
Fax #: (613) 248-2260
E-mail: [email protected]
Address: 1 Innovation Drive
Renfrew, ON K7V 4B1
Toxics Substance Reduction Plan Summary – Particulate Matter PM10 (CAS # NA-M09)
1 Innovation Drive, Renfrew, ON December 19, 2013
Ensyn Technologies Inc. Pinchin File: 89489
© 2013 Pinchin Environmental Ltd. Page 2
2.0 STATEMENT OF INTENT
Ensyn is committed to playing a leadership role in protecting the environment. Whenever
feasible, we will eliminate, or reduce the use and releases of Particulate Matter (PM10) in
compliance with all Federal and Provincial regulations.
PM is created as a by-product during the material handling and conversion processes. PM is not
intentionally added to the process.
Ensyn considered the substitution of the process media as a potential PM10 reduction options but
unfortunately it is not a viable option since the material costs are about 70% greater and the
annual operating costs were shown to increase by about 20%.
Consequently, at the present time, there are no toxic reduction options that were identified that
will be implemented. Ensyn will continue to monitor new technologies as they emerge.
With reference to the Ontario Toxics Reduction Act, the reduction objectives are outlined in
Section 4 of this Plan Summary.
3.0 SUBSTANCES REQUIRING PLANS
The following substance requires a plan – PM10 - based on 2012 Toxics Reduction Act
accounting information.
PM is created as a by-product during the material handling and conversion process. PM is not
intentionally added to the process.
4.0 OBJECTIVES OF THE PLAN & ANY TARGETS
Ensyn prides itself on technological innovation in order to produce high quality products in an
environmentally responsible manner. We will strive to minimize the creation of Particulate
Matter (PM10) at the facility.
Technical and economic feasibility analysis was conducted on a reduction option but
unfortunately it was not a viable option. Consequently, no options have been identified that will
be implemented, but and as part of the continuous improvement practices at the facility,
technology advances will be monitored for new opportunities to reduce the use of Particulate
Matter (PM10) at the facility.
5.0 OPTIONS TO BE IMPLEMENTED (OR STATEMENT THAT NONE ARE TO
BE IMPLEMENTED)
Ensyn’s commitment to continuous improvement has resulted in an extraordinarily lean and
efficient manufacturing facility. PM10 is created at the facility due to material handling and the
thermal conversion process. PM10 is not added to the process.
Toxics Substance Reduction Plan Summary – Particulate Matter PM10 (CAS # NA-M09)
1 Innovation Drive, Renfrew, ON December 19, 2013
Ensyn Technologies Inc. Pinchin File: 89489
© 2013 Pinchin Environmental Ltd. Page 3
A process media substitution option was considered as a potential option to reduce the PM10
creation but financial analysis proved the option to be non-viable as it increased annual costs by
18%. Consequently, at this point in time, no toxic reduction options were identified for
implementation that would reduce the amount of PM10 created at the facility. Ensyn will
continue to investigate new technologies and advances as they emerge.
6.0 CONTENTS OF THIS PLAN SUMMARY REFLECTS PLAN
This Plan Summary accurately reflects the Toxic Substance Reduction Plans dated December 19,
2013, prepared for the substances listed in Section 1.0 of this Summary.
Toxics Substance Reduction Plan Summary – Particulate Matter PM10 (CAS # NA-M09)
1 Innovation Drive, Renfrew, ON December 19, 2013
Ensyn Technologies Inc. Pinchin File: 89489
© 2013 Pinchin Environmental Ltd. Page 5
8.0 CERTIFICATION BY LICENSED PLANNER
As of December 20th
, 2013, I, Phil Girard, certify that I am familiar with the processes at Ensyn
Technologies Inc., located at 1 Innovation Drive, Renfrew, ON that use or create the toxic
substances referred to below, that I agree with the estimates referred to in subparagraphs 7 iii, iv
and v of subsection 4 (1) of the Toxics Reduction Act, 2009 that are set out in the toxic substance
reduction plans referred to below for the toxic substances and that the plans comply with that Act
and Ontario Regulation 455/09 (General) made under that Act.
Particulate Matter (PM10; CAS: NA-M09)
Phil Girard, License #TSRP 019
V.P.
Pinchin Environmental Ltd.
Pinchin Master Report Guide, Ver. 1, May 2007
Document4