Upload
truongcong
View
216
Download
1
Embed Size (px)
Citation preview
ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓROOF AND WALL STEEL SHEETS
TPS 40.1000
PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS
FALC
ON
1
34
/ 2
00
.4 /
2ó
ô
P. 1
1/0
7
www.panelco.gr
PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS
ÅñãïóôÜóéï: ÂÉÐÅ Ëáìßáò, Ï.Ô. 4Â, 35100, Ëáìßá, Ôçë.: 22310-66122-3, Fax: 22310-43771ïÃñáöåßá Íüôéáò ÅëëÜäáò & Åîáãùãþí: 54 ÷ëì. ÅèíéêÞò ïäïý Áèçíþí-Ëáìßáò, ÈÝóç Ëõóßá, 32011, Ïéíüöõôá, Âïéùôßá
Ôçë.: 22620-32200, Fax: 22620-30791Ãñáöåßá Âüñåéáò ÅëëÜäáò: Ðáëáéüêáóôñï, 57200, Ùñáéüêáóôñï, Èåóóáëïíßêç, Ôçë.: 2310-687935, Fax: 2310-687924
Production Plant: Industrial Zone of Lamia, S.B. 4B, 35100, Lamia, GREECE. Tel.:+30 22310-66122-3, Fax: +30 22310-43771thSales Southern Greece and Exports: 54 km Athens-Lamia National Road, Thesi Lisia, 32011, Inofita-Viotia, GREECE
Tel.: +30 22620-32200, Fax: +30 22620-30791Sales Northern Greece: Paleokastro, 57200, Oreokastro-Thessaloniki, GREECE, Tel.: +30 2310-687935, Fax: +30 2310-687924
ÅËÁÓÌÁÔÁ
ÅðéøåõäáñãõñùìÝíïò åí èåñìþ ÷Üëõâáò êáôÜ ÅÍ 10142: 90/ Á1 95, ÅÍ 10147:91/ êáé A1 95 EN 10143, óå ðÜ÷ç áðü 0,40mm Ýùò 0,75mm, ðñïâáììÝíïò ìå ðïëõåóôåñéêÞ âáöÞ 25ì (ÅÍ 10169-1/03).Êáôüðéí åéäéêÞò ðáñáããåëßáò ìðïñïýí åðßóçò íá ÷ñçóéìïðïéçèïýí: á) INOX â) Áëïõìßíéïã) ÃáëâáíéóìÝíïò ÷Üëõâáò ìå åðéêïëëçìÝíï öéëì PVC 150ì Þ ìå âáöÞ PVDF áðü 40ì - 60ì, ùò åðßóçò âáöÞ HDP.
SHEETS
Zinc-coated, hot rolled steel per ÅÍ 10142: 90/ Á1 95,ÅÍ 10147:91/ and A1 95 EN 10143, in thicknesses ranging from 0.40mm to 0.75mm, pre-painted with polyester coating25ì (ÅÍ 10169-1/03).The following can be also used under special agreement: a) INOX b) Aluminium c) Galvanized steel, coated with PVC 150ì film or painted with PVDF 40ì - 60ì, as well as HDP paint.
1,00
438
610
750
560
768
950
1,25
280
390
490
355
481
605
1,50
185
273
340
242
331
415
1,75
143
200
250
170
240
300
2,00
95
138
180
130
180
230
2,25
75
100
129
100
140
180
2,50
X
70
90
80
110
143
2,75
X
X
80
X
90
115
3,00
X
X
X
X
X
90
0.50
0.60
0.75
0.50
0.60
0.75
5,00
6,00
7,50
5,00
6,00
7,50
MULTIPLE SPAN SUPPORT
ÓÔÇÑÉÎÇ ÐÏËËÁÐËÙÍ ÁÍÏÉÃÌÁÔÙÍ
ÁÌÖÉÅÑÅÉÓÔÇ ÓÔÇÑÉÎÇ
BOTH END SUPPORT
ÐÁ×ÏÓ S
(m
m)
THICKN
ESS
S (m
m)
ÂÁ
ÑÏ
Ó/Ì
ÅÔÑÏ
WEI
GHT
(kg/m
²)
L/200
TPS 40.1000
PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS
MATERIAL APPLICATIONS -SPECIFICATIONS
TPS 40.1000 is used for roof and wall cladding in constructions requiring no thermal insulation. In addition, it can be used in existing building façade redevelopment. In its perforated type, the specific product can also meet certain sound insulation needs when used in double sheet with inner sound insulation material. The above profile can be produced also in curved shape, for use in cladding buildings of special designs.
ÅÖÁÑÌÏÃÅÓ - ÐÑÏÄÉÁÃÑÁÖÅÓ ÕËÉÊÙÍ
Ôï TPS 40.1000 ÷ñçóéìïðïéåßôáéãéá åðéêáëýøåéò êáé ðëáãéïêáëýøåéò êôéñßùí, óôá ïðïßá äåí áðáéôåßôáé èåñìïìüíùóç. ÅðéðëÝïí ìðïñåß íá ÷ñçóéìïðïéçèåß ãéá äéáìïñöþóåéò üøåùí õöéóôáìÝíùí êôéñßùí ðïõ ÷ñåéÜæïíôáé ðáñåìâÜóåéò.Ìå ôç äõíáôüôçôá ðáñáãùãÞò ôïõ êáé óå äéÜôñçôç ìïñöÞ êáëýðôåé áíÜãêåò ç÷ïðñïóôáóßáò üôáí ÷ñçóéìïðïéåßôáé äéðëü Ýëáóìá ìå åíäéÜìåóç ç÷ïðñïóôáôåõôéêÞ ìüíùóç.ÔÝëïò óçìåéþíåôáé üôé ôï ðáñáðÜíù ðñïößë ìðïñåß íá ðáñá÷èåß êáé óå êáìðýëç ìïñöÞ äßíïíôáò ôç äõíáôüôçôá íá êáëýðôïõìå êôßñéá
TPS 40.1000ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓROOF AND WALL STEEL SHEETS
1000mm
40mm
250mm
ÁÍÏÉÃÌÁÔÁ ÔÅÃÉÄÙÍ (m)PURLIN DISTANCE (m)
ÏÌÏÉÏÌÏÑÖÁ ÊÁÔÁÍÅÌÇÌÅÍÏ ÖÏÑÔÉÏ (kg/m²)PERMISSIBLE LOADS (kg/m²)