2
ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓ ROOF AND WALL STEEL SHEETS TPS 40.1000 PANELCO METAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS FALCON 134 / 200.4 / 2óô P. 11/07 www.panelco.gr PANELCO METAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS ÅñãïóôÜóéï: ÂÉÐÅ Ëáìßáò, Ï.Ô. 4Â, 35100, Ëáìßá, Ôçë.: 22310-66122-3, Fax: 22310-43771 ï Ãñáöåßá Íüôéáò ÅëëÜäáò & Åîáãùãþí: 54 ÷ëì. ÅèíéêÞò ïäïý Áèçíþí-Ëáìßáò, ÈÝóç Ëõóßá, 32011, Ïéíüöõôá, Âïéùôßá Ôçë.: 22620-32200, Fax: 22620-30791 Ãñáöåßá Âüñåéáò ÅëëÜäáò: Ðáëáéüêáóôñï, 57200, Ùñáéüêáóôñï, Èåóóáëïíßêç, Ôçë.: 2310-687935, Fax: 2310-687924 Production Plant: Industrial Zone of Lamia, S.B. 4B, 35100, Lamia, GREECE. Tel.:+30 22310-66122-3, Fax: +30 22310-43771 th Sales Southern Greece and Exports: 54 km Athens-Lamia National Road, Thesi Lisia, 32011, Inofita-Viotia, GREECE Tel.: +30 22620-32200, Fax: +30 22620-30791 Sales Northern Greece: Paleokastro, 57200, Oreokastro-Thessaloniki, GREECE, Tel.: +30 2310-687935, Fax: +30 2310-687924

TPS 40 - PANELCO · tps 40.1000 panelco metal composite panels & construction elements falcon 134 / 200.4 / 2óô p. 11/07 panelco ... m m) t h i c k n e s s s (m)

Embed Size (px)

Citation preview

ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓROOF AND WALL STEEL SHEETS

TPS 40.1000

PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS

FALC

ON

1

34

/ 2

00

.4 /

ô

P. 1

1/0

7

www.panelco.gr

PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS

ÅñãïóôÜóéï: ÂÉÐÅ Ëáìßáò, Ï.Ô. 4Â, 35100, Ëáìßá, Ôçë.: 22310-66122-3, Fax: 22310-43771ïÃñáöåßá Íüôéáò ÅëëÜäáò & Åîáãùãþí: 54 ÷ëì. ÅèíéêÞò ïäïý Áèçíþí-Ëáìßáò, ÈÝóç Ëõóßá, 32011, Ïéíüöõôá, Âïéùôßá

Ôçë.: 22620-32200, Fax: 22620-30791Ãñáöåßá Âüñåéáò ÅëëÜäáò: Ðáëáéüêáóôñï, 57200, Ùñáéüêáóôñï, Èåóóáëïíßêç, Ôçë.: 2310-687935, Fax: 2310-687924

Production Plant: Industrial Zone of Lamia, S.B. 4B, 35100, Lamia, GREECE. Tel.:+30 22310-66122-3, Fax: +30 22310-43771thSales Southern Greece and Exports: 54 km Athens-Lamia National Road, Thesi Lisia, 32011, Inofita-Viotia, GREECE

Tel.: +30 22620-32200, Fax: +30 22620-30791Sales Northern Greece: Paleokastro, 57200, Oreokastro-Thessaloniki, GREECE, Tel.: +30 2310-687935, Fax: +30 2310-687924

ÅËÁÓÌÁÔÁ

ÅðéøåõäáñãõñùìÝíïò åí èåñìþ ÷Üëõâáò êáôÜ ÅÍ 10142: 90/ Á1 95, ÅÍ 10147:91/ êáé A1 95 EN 10143, óå ðÜ÷ç áðü 0,40mm Ýùò 0,75mm, ðñïâáììÝíïò ìå ðïëõåóôåñéêÞ âáöÞ 25ì (ÅÍ 10169-1/03).Êáôüðéí åéäéêÞò ðáñáããåëßáò ìðïñïýí åðßóçò íá ÷ñçóéìïðïéçèïýí: á) INOX â) Áëïõìßíéïã) ÃáëâáíéóìÝíïò ÷Üëõâáò ìå åðéêïëëçìÝíï öéëì PVC 150ì Þ ìå âáöÞ PVDF áðü 40ì - 60ì, ùò åðßóçò âáöÞ HDP.

SHEETS

Zinc-coated, hot rolled steel per ÅÍ 10142: 90/ Á1 95,ÅÍ 10147:91/ and A1 95 EN 10143, in thicknesses ranging from 0.40mm to 0.75mm, pre-painted with polyester coating25ì (ÅÍ 10169-1/03).The following can be also used under special agreement: a) INOX b) Aluminium c) Galvanized steel, coated with PVC 150ì film or painted with PVDF 40ì - 60ì, as well as HDP paint.

1,00

438

610

750

560

768

950

1,25

280

390

490

355

481

605

1,50

185

273

340

242

331

415

1,75

143

200

250

170

240

300

2,00

95

138

180

130

180

230

2,25

75

100

129

100

140

180

2,50

X

70

90

80

110

143

2,75

X

X

80

X

90

115

3,00

X

X

X

X

X

90

0.50

0.60

0.75

0.50

0.60

0.75

5,00

6,00

7,50

5,00

6,00

7,50

MULTIPLE SPAN SUPPORT

ÓÔÇÑÉÎÇ ÐÏËËÁÐËÙÍ ÁÍÏÉÃÌÁÔÙÍ

ÁÌÖÉÅÑÅÉÓÔÇ ÓÔÇÑÉÎÇ

BOTH END SUPPORT

ÐÁ×ÏÓ S

(m

m)

THICKN

ESS

S (m

m)

ÂÁ

ÑÏ

Ó/Ì

ÅÔÑÏ

WEI

GHT

(kg/m

²)

L/200

TPS 40.1000

PANELCOMETAL COMPOSITE PANELS & CONSTRUCTION ELEMENTS

MATERIAL APPLICATIONS -SPECIFICATIONS

TPS 40.1000 is used for roof and wall cladding in constructions requiring no thermal insulation. In addition, it can be used in existing building façade redevelopment. In its perforated type, the specific product can also meet certain sound insulation needs when used in double sheet with inner sound insulation material. The above profile can be produced also in curved shape, for use in cladding buildings of special designs.

ÅÖÁÑÌÏÃÅÓ - ÐÑÏÄÉÁÃÑÁÖÅÓ ÕËÉÊÙÍ

Ôï TPS 40.1000 ÷ñçóéìïðïéåßôáéãéá åðéêáëýøåéò êáé ðëáãéïêáëýøåéò êôéñßùí, óôá ïðïßá äåí áðáéôåßôáé èåñìïìüíùóç. ÅðéðëÝïí ìðïñåß íá ÷ñçóéìïðïéçèåß ãéá äéáìïñöþóåéò üøåùí õöéóôáìÝíùí êôéñßùí ðïõ ÷ñåéÜæïíôáé ðáñåìâÜóåéò.Ìå ôç äõíáôüôçôá ðáñáãùãÞò ôïõ êáé óå äéÜôñçôç ìïñöÞ êáëýðôåé áíÜãêåò ç÷ïðñïóôáóßáò üôáí ÷ñçóéìïðïéåßôáé äéðëü Ýëáóìá ìå åíäéÜìåóç ç÷ïðñïóôáôåõôéêÞ ìüíùóç.ÔÝëïò óçìåéþíåôáé üôé ôï ðáñáðÜíù ðñïößë ìðïñåß íá ðáñá÷èåß êáé óå êáìðýëç ìïñöÞ äßíïíôáò ôç äõíáôüôçôá íá êáëýðôïõìå êôßñéá

TPS 40.1000ËÁÌÁÑÉÍÁ ÏÑÏÖÇÓ ÊÁÉ ÐËÁÃÉÏÊÁËÕØÇÓROOF AND WALL STEEL SHEETS

1000mm

40mm

250mm

ÁÍÏÉÃÌÁÔÁ ÔÅÃÉÄÙÍ (m)PURLIN DISTANCE (m)