Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
VISIONVISIONVISIONVISION
Excellence in Creating Innovative Solutions
for the
Supply, control and Use of Energy
Locations
TRACM
LET TAW DO THE
TRACKING FOR YOU
ALERT NOTICE
SENT TO QA
IF FAILED < MTBF
TRACM CLERK
ENTERS
WO INFO
TAW SHOP
GENERATES WORK ORDER
ALERT NOTICE
SENT TO QA
IF WARRANTY
PICK UP MOTOR
TRACM FLOW CHART
TBF MTBF WARRANTY WORK SCOPE FAILURE CODE MAINTENANCE
TRACM CLERK UPDATES
WO INFO AND SETS
MOTOR REPAIR
AND SENT BACK
TO CUSTOMER
MOTOR EVALUATED
OFFER SENT FOR
APPROVAL
• Search capability by equip#, serial#, HP, Frame
or Location
• Delivery date from new sales or repairs
TRACM-Tracking Rotating Apparatus
and Controls Management
• Delivery date from new sales or repairs
Installation date
• Location number, showing plant, area equipment
• Warranty start date
• Warranty end date
• Warranty type; repair or new factory warranty
• MXP job shop will flag when a work order is
opened and unit is still covered under factory or opened and unit is still covered under factory or
repair warranty.
• Measures TBF and MTBF of all units, MXP job
shop will flag if work order is opened and unit is
less than it’s MTBF.
• Unit interchangeability or unique use, system will
identify critical units and their exchange units
thereby allowing user to locate all critical spares
and their condition.
• Nameplate information
• Physical characteristics; base diameter, coupling
info, shaft information., etc. info, shaft information., etc.
• Cause of failure code and description
• Associated equipment; controls, gearbox, pump,
conveyor, etc.
• Repair history to include when completed; where
delivered with date, installed date, work scope and
cause of failure.
• Allows for attachment of photos, manuals,
reports, etc.
• Tracking movement of unit from stores to
location, from location to repair/where, back to
stores, location to location, etc.
• TAW TRACM includes new equipment and
consignment. consignment.
• Maintenance scheduling; Track maintenance of
units for quarterly megger tests and shaft
rotations and produce list of units requiring
specific maintenance at specific intervals. This
could be used for vibration testing, preventative
maintenance, checking brushes, lubrication, etc.
• TAW’s current motor repair computer system has
been in place since 1997, thereby allowing all past
history with work scope and costs to input into
TAW unit track system.
• Efficiency rating for motors are tied to the “Motor
Master” formula to allow customer to determine
operating cost of motors. operating cost of motors.
• Repair flow schedules for existing units in shop are
available upon request.
• 1. Stores list by location
• 2. Motors “In-operation” by location
• 3. Motors by location by cause of failure (with
repair value)
• 4. Failures within warranty period
Reports:
• 4. Failures within warranty period
• 5. MTBF by location
• 6. Maintenance scheduling reports
Go to http://www.tawinc.com/
Click on
Members
Area
Click on TRACM
Type in your User ID
Type in your Cust NO
And your Password
Welcome Customer
COVER PAGE
All fields are search
engines either by
themselves or in
combination with
others.
TRACKING
• Motors
• Pumps
• Switch gear
• Shop equipment
• Vehicles
RPM
Reference will
allow you to find
the range of RPM.
LOCATION
Welcome Customer
LOCATION
TIER 1
Will help you narrow
your search.
TIER 2, TIER 3, TIER 4
Will show you exactly
where unit is located.
STATUS
Allows you to see
what status your
unit is in.
Example:
Stock
Service
Welcome Customer
Service
Repair
CRITICAL
By choosing YES
in the CRITICAL
box, you can bring
up specific units
and their spares.
Welcome Customer
Welcome Customer
EXCHANGE
CODE
The critical unit
and it’s spare will
have the same code.
This will enable you
to find your spare
for when thefor when the
critical is in repair.
NEW STOCK
Will show you
• Purchase date
• Installation date
• Vender
• Warranty information
Processing Plant
WARRANTY
• FACTORY
• RECONDITION
• REWIND
Will automatically flag
TAW and Customer for
failures withinfailures within
warranty period and
failures less than unit’s
MTBF.
Processing Plant
DETAIL
INFORMATION
• Nameplate
• Maintenance
• Repair History
• Location History
• Pics & Docs
Processing Plant
ATTACHMENTS
Shows attached units to
primary unit.
Processing Plant
Power Unit
Shows power source for
primary unit; starter,
drive, etc...
Driven Unit
Shows driven unit for
primary unit; gearbox,primary unit; gearbox,
pump, fan, motor, etc...
NAMEPLATE PAGE
References all pertinent
information about the unit,
including weight, dimensions,
and special physical
characteristics.
EFFICIENCYEFFICIENCY
RATING FIELD
This will allow user to
determine electrical
operating cost of unit.
Every 3 months our tech will do a megger reading test and turn
the rotor shaft.
A maintenance report is generated each month for work to be
performed.
TAW CAN PROVIDE LIFE
CYCLE MANAGEMENT
SERVICES ON ALL
ROTATING EQUIPMENT
LIFE CYCLE MANAGEMENT OF ROTATING
EQUIPMENT
• New Stock
• Sent out for repair
• Sent out for service
• Inoperable
• Scrapped
• Sold
REPAIR HISTORY
Shows repair history performed by TAW since 1997.
Also shows Time Between Failure for each repair and
Mean Time Between Failure.
REPAIR INFORMATION
• Shows type of repair
• Shows cause of failure
• Repair specifics
01/19/07 02/20/07 Processing Plant Whs Incorrect location
01/11/07 01/19/07 TAW Move to stock
Tampa Service Center
Small Motor Division
06/20/06 01/11/07 North Screening Send out for repairWarehouse
06/06/06 06/20/06 TAW Move to stock
LOCATION HISTORY
Shows where unit has been, how
long and why it was moved.
06/06/06 06/20/06 TAW Move to stock
Tampa Service Center
Small Motor Division
PICS & DOCS
Processing Plant
PICS & DOCS
• Attach Pictures
• Attach
Dimension prints
• Attach word
documentsdocuments
PDMA Attachment
Test Date 1/09/07
Test Time 10:44:34 AM
Base line
Frequency 1200
Mohm PH 1 to Gnd
Change time 60
Voltage 5000
Motor Temp 21
Measured Mohm 20050.0
Corrected Mohm 5400:0
pF Ph 1 to Gnd 49750
ohm Ph 1 to 2 0.33600
ohm Ph 1 to 3 0.33600
Customer 333555 (MCE Stator / AC Standard )
ohm Ph 2 to 3 0.33700
mH Ph 1 to 2 21.450
mH Ph 1 to 3 21.500
mH Ph 2 to 3 21.830
Avg. Inductance 21.593
% Res. Imbalance 0.20
% Ind. Imbalance 1.10
$Power Loss 6.80
Tested Location Motor Leads
MCE# 031063HV
User
Notes no
TAW TRACM Cost Report
For CUSTOMER All Type of February Year 2007
Unit ID HP FRAME MFG VOLT RPM TYPE PO COST
E06T0657SD0004 5 184TC Siemens 230/460 3600 NEW STOCK 386.51
E06T0657SD0015 5 184TC Siemens 230/460 3600 NEW STOCK 386.51
10151M 600 5012PA US Motors 4160 1180 RC U50844 5052
10791 200 1685 IDEAL 4160 1180 RC U50379 7051.9
20038 200 504UU Allis Chalmers 4160 1185 RC U50380 5047.5
4C0778 200 505UZ Toshiba 460 1180 RC U49079 3105.11
4C1324 250 315L Toshiba 4160 1775 RC U50382 4877.04
9741M 800 8411Z General Electric 4000 585 RC U50863 11963.31
9800M 350 5809Z AC350HP1Z00RPM 4160 1189 RC U50441 9675.93
ACCO2282 500 6336P30 General Electric 4160 1200 RC U50851 5383.18
COST REPORT
Can be generated monthly at customer’s
request.
ACCO2282 500 6336P30 General Electric 4160 1200 RC U50851 5383.18
12993 900 560-1000 Toshiba 2400/4160 585 RW U50839 20240.42
14405 1500 560/1400 Toshiba 4160 506 RW U50530 9372.04
4C0764 1000 8004S US Motors 4160 505 RW U48576 28575.58
9601M 300 5011L General Electric 4160 1190 SCRAP U54545 1066
NEW STOCK 773.02
Recondition 52155.97
Rewind 58188.04
Scrapped at TAW 1066
GRAND TOTAL: 112183.03
END-OF-REPORT
TAW TRACM Failure Report
For CUSTOMER All Type of February Year 2007
FAILURE Unit ID HP FRAME MFG VOLT RPM REPAIR# TBF COST
Stator winding grounded 12993 900 560-1000 Toshiba 2400/4160 585 178415 2657 20240.42
4C0764 1000 8004S US Motors 4160 505 174061 706 28575.58
Due to water in the motor.
9601M 300 5011L General Electric 4160 1190 177147 0 1066
Rotor hit stator hard and the winding is grounded
Stator winding contamination 4C1324 250 315L Toshiba 4160 1775 175671 0 4877.04
Drive end bearing failure ACCO2282 500 6336P30 General Electric 4160 1200 178418 876 5383.18
DE and ODE bearing failure 10151M 600 5012PA US Motors 4160 1180 178416 0 5052
FAILURE REPORT
Shows type of failure, by location,
by time period, TBF and cost.
DE and ODE bearing failure 10151M 600 5012PA US Motors 4160 1180 178416 0 5052
4C0778 200 505UZ Toshiba 460 1180 176950 0 3105.11
Due to contamination.
Opposite drive end brg failure 20038 200 504UU Allis Chalmers 4160 1185 176386 0 5047.5
Due to contamination in lube
Product in unit 10791 200 1685 IDEAL 4160 1180 176385 1289 7051.9
Contamination in motor and bearings
GRAND TOTAL: 80398.73
END-OF-REPORT