Triangle Flexible LSZH Shipboard/Offshore
Cables issue 9.1
www.tricab.com Superior Cable Solutions
1 Kuwaiti patrol boats. Designed and built by Austal Ships Australia.
www.austal.com
2 Production platform in Gulf of Thailand
3 ‘Sovereign Lady’ built by Sovereign Yachts New Zealand Limited.
www.sovereignyachts.co.nz
4 ’Benchijigua Express’ - 416ft high speed vehicle-passenger trimaran ferry by
Austal Ships Pty Ltd, WA. www.austal.com
1
2
4
3
Approvals
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E
8 . 0 . 12
CONTENTS
S H I P B O A R D C A B L E S
PR
OD
UCT
SE
RIE
S
Flam
e R
etar
dant
IEC
6033
2-1
AS
/NZS
1660
.5.6
Flam
e R
etar
dant
IEC
6033
2-3A
AS
/NZS
1660
.5.1
Hal
ogen
Fre
e
IEC
6075
4-1&
2
AS
/NZS
1660
.5.3
Sm
oke
Em
issi
on
IEC
6103
4-1&
2
AS
/NZS
1660
.5.2
Fire
Res
ista
nt
IEC
6033
1 A
S/N
ZS16
60.5
.5PA
GE
NU
MB
ER
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 12
Introduction 4
Low Smoke Zero Halogen (LSZH) - what does it mean? 6
Features and Benefits 8
POWER AND CONTROL
Unarmoured BV ✓ ✓ ✓ ✓ ✕ 12
Unarmoured MK ✓ ✓ ✓ ✓ ✕ 14
Braided/Armoured DV ✓ ✓ ✓ ✓ ✕ 16
INSTRUMENTATION
Collective screened
Unarmoured RC ✓ ✓ ✓ ✓ ✕ 18
Braided/Armoured RS ✓ ✓ ✓ ✓ ✕ 20
Individual and collective screened
Unarmoured EW ✓ ✓ ✓ ✓ ✕ 22
Braided/Armoured EG ✓ ✓ ✓ ✓ ✕ 24
POWER AND CONTROL – F i re Resistant
Unarmoured RR ✓ ✓ ✓ ✓ ✓ 26
Braided/Armoured BH ✓ ✓ ✓ ✓ ✓ 28
INSTRUMENTATION – F i re Resistant
Collective screened
Unarmoured ES ✓ ✓ ✓ ✓ ✓ 30
Braided/Armoured FJ ✓ ✓ ✓ ✓ ✓ 32
Individual and collective screened
Unarmoured FC ✓ ✓ ✓ ✓ ✓ 34
Braided/Armoured FL ✓ ✓ ✓ ✓ ✓ 36
SHOREPOWER EZ ✓ ✓ ✓ ✓ ✕ 38
SWITCHBOARD/PANEL WIRE UP ✓ ✓ ✓ ✓ ✕ 40
T E C H N I C A L I N F O R M A T I O N
O F F S H O R E O I L A N D G A S C A B L E S
PR
OD
UCT
SE
RIE
S
Flam
e R
etar
dant
IEC
6033
2-1
AS
/NZS
1660
.5.6
Flam
e R
etar
dant
IEC
6033
2-3A
AS
/NZS
1660
.5.1
Hal
ogen
Fre
e
IEC
6075
4-1&
2
AS
/NZS
1660
.5.3
Sm
oke
Em
issi
on
IEC
6103
4-1&
2
AS
/NZS
1660
.5.2
Fire
Res
ista
nt
IEC
6033
1 A
S/N
ZS16
60.5
.5PA
GE
NU
MB
ER
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 3
POWER AND CONTROL
Braided/Armoured PJ ✓ ✓ ✓ ✓ ✕ 42
INSTRUMENTATION
Collective screened
Braided/Armoured RB ✓ ✓ ✓ ✓ ✕ 44
Individual and collective screened
Braided/Armoured FZ ✓ ✓ ✓ ✓ ✕ 46
POWER AND CONTROL – F i re Resistant
Braided/Armoured HT ✓ ✓ ✓ ✓ ✓ 48
INSTRUMENTATION – F i re Resistant
Collective screened
Braided/Armoured FK ✓ ✓ ✓ ✓ ✓ 50
Individual and collective screened
Braided/Armoured FE ✓ ✓ ✓ ✓ ✓ 52
SWITCHBOARD/PANEL WIRE UP ✓ ✓ ✓ ✓ ✕ 54
55
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 14
INTRODUCTION
Welcome to Issue 9.1 of our Shipboard/Offshore catalogue.
Triangle has been manufacturing and supplying specialized cables to the marine industry for over 30 years.
Our aim has always been to design and manufacture the most innovative cables possible, and supply them in the
most customer focused manner possible.
As a privately owned, family enterprise, we retain old fashioned values in how we conduct business and how we
treat our customers, our suppliers and our dedicated Triangle team.
Over the years, we have expanded our manufacturing and sales facilities throughout the world. We now operate
three production plants and fifteen sales/distribution offices. (see back page for details).
We have also significantly expanded our product range and associated Certifications/Approvals. We now produce
cables that conform to AS/NZS1660, IEC60092-350, IEEE45, IEEE1580,TypeP, BS6883 and NEK606(MUD).
We have developed proprietary processes and raw materials, that enable us to produce highly flexible LSZH
cables with reduced Bending Radius. This saves installation time and reduces both space and cable usage.
We look forward to personally discussing your requirements, and providing cost-effective solutions that add value
to your business.
108ft Orca Class inshore patrol vessel by Victoria Shipyard, Victoria BC
LSZHLSZH simply translates to Low Smoke Zero Halogen and refers to the behaviour ofchemical compounds when combusted - specifically the quantity of smoke generatedand the toxicity of the emissions.
Halogens - What are they?Halogens are a group of five elements comprising; Fluorine, Chlorine, Bromine, Iodineand Astatine.
Halogens - and the effect of combustionIn their basic form, Halogens are very toxic, strong oxidizers and very chemicallyreactive. In the event of combustion, LSZH and non LSZH cables behave in verydifferent ways, as indicated below.
Fluorine Chlorine Bromine Iodine Astatine
Triangle LSZH Cables
NO HALOGENS HALOGEN EMISSIONS
CORROSIVEACIDS
LOW SMOKE DENSE SMOKE
NO ACIDS
Non LSZH Cables
LOW SMOKE ZERO HALOGEN (LSZH)What does it mean?
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 16
What is the difference between LSZH and non LSZHcables?
LSZH cables have a zero Halogen content, emit no toxic fumes,generate very little smoke and produce no corrosive or causticacids. LSZH cables are therefore ideally suited for all marineapplications where personnel safety and protection of valuableequipment are of paramount importance.
Non LSZH cables, or Halogenated Cables, are typicallymanufactured from thermoplastic compounds, such as PVC. Oncombustion, these compounds generate highly toxic fumes thatcause severe irritation to the eyes, nose, mouth, throat andlungs. Increased concentrations are considered fatal to humans.
They also generate large volumes of dense black smoke thatblocks visibility and severely disrupts evacuation procedures. Thesmoke and fumes can also lead to suffocation from smokeinhalation. A one metre length of burning cable that contains
Triangle LSFLEX® - Insulation & Jacket Materials✓ are halogen free
✓ emit low smoke
✓ do not form corrosive acids
✓ have an extremely low fuel element
LOW SMOKE ZERO HALOGEN (LSZH)What does it mean?
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 7
IEC 60332-1IEC 60332-3(A)IEC 60754-1&2IEC 61034-1&2
AS/NZS1660.5.1AS/NZS1660.5.2AS/NZS1660.5.3AS/NZS1660.5.6
Triangle LSFLEX® - Insulation & Jacket Materials comply to the following standards:
Fine Copper Stranding - Triangle uses very fine 0.3mmcopper wire for all conductors, in accordance with IEC60228 Class 5&6 and AS/NZS 1125.
Round Concentric Cores - Triangle exclusively manufactures round cores throughout its entire size range,and does not use sectorial conductors.
Lightweight - Triangle has developed specific productranges that have reduced weight.
Small OD - Triangle has developed specific product rangesthat have reduced OD's.
Flexible Construction - Triangle uses a combination offine conductors, special compounds and manufacturingprocess to produce a very flexible cable.
Metre marking - All Triangle cables are metre-marked asstandard, with a descending number (feet marking alsoavailable).
Product marking - Triangle offers personalized text mes-sages printed onto the cable at regular intervals, even forshort lengths.
Make to order facility - Triangle can manufacture cablesexactly to customer specifications.
•
•
•
•
•
•
•
•
F E A T U R E S B E N E F I T S
Significantly increased flexibility has numerous practical benefits, including reduced installation time and easiercable handing. These benefits translate directly intoreduced installation time and cost.
Standard lugs, terminals and connectors can be used, saving installation time, inventory and cost - also providingbetter electrical contact with standard round lugs.
Especially relevant to high speed craft, sailing yachts etc.where weight saving translates into improved performanceand overall cost benefits. Makes handling much easierduring installation.
Additional cables can be installed within a specified cabletray, ladder or conduit. A smaller bending radius benefitstight configurations, and smaller glands reduce cost.
Reduced installation time and cost, improved bendingradius and safer cable handling (especially larger sizes).
Assists the installation process and enables accurate stockmanagement.
Project Reference Codes, Company Name, Part Numbers,Quality Data, Marketing Information etc. can all be clearlymarked.
No need for the user to compromise or accept an alterna-tive cable. Customers receive exactly what they need.
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 18
FEATURES AND BENEFITS
Global distribution - Triangle operates its own network ofcompany offices and warehouses worldwide. We currently have operations in Australia, NZ, North America and Asia.
Research & development - Triangle maintains a veryactive R&D programme. Working very closely with our salesteam and customers, we are continually improving cableperformance.
Quick response - Triangle has invested in manpower,machinery and materials to provide a short leadtimemanufacturing capability.
Reliable long-term partner - Triangle has been supplyinginnovative cable solutions since 1978. We believe in longterm partnerships and have a solid track record of successfully completed projects worldwide.
Approvals - Triangle maintains approvals from numerouscertification bodies, including LR, DNV, ABS, BV, GL, UL,CSA. If required, we also obtain specific case approval.
Quality accreditation - Triangle operates an accreditedQuality system in accordance with ISO 9001:2008, bothwithin our manufacturing plant and our global offices and warehouses.
We support customer projects wherever they may be,streamlining logistics, increasing supply reliability and saving time and money.
New cable technologies are introduced to our customerson an ongoing basis.
When cable is needed urgently, either due to an emer-gency or unexpected contingency, Triangle has the systemsin place to fast-track the manufacturing process, reducingdowntime and saving time and money.
We believe that satisfied customers are our strength andwe do everything in our power to ensure that we both growand prosper over the long term.
Reliable certification simplifies the task for procurementand engineering, saving time and money. It also allowscables left over from one project to be used for future projects.
We continually improve our quality performance, which in turn provides improved products and services to ourcustomers.
•
•
•
•
•
•
F E A T U R E S B E N E F I T S
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 9I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 9
SHIPBOARD CABLES
POWER AND CONTROL
Unarmoured BV 12
Unarmoured MK 14
Braided/Armoured DV 16
INSTRUMENTATION
Collective screened
Unarmoured RC 18
Braided/Armoured RS 20
Individual and collective screened
Unarmoured EW 22
Braided/Armoured EG 24
POWER AND CONTROL – F i re Resistant
Unarmoured RR 26
Braided/Armoured BH 28
INSTRUMENTATION – F i re Resistant
Collective screened
Unarmoured ES 30
Braided/Armoured FJ 32
Individual and collective screened
Unarmoured FC 34
Braided/Armoured FL 36
SHOREPOWER EZ 38
SWITCHBOARD/PANEL WIRE UP 40
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 112
BV
CONSTRUCTIONConductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications.
NUMBER OF MINIMUM CONDUCTOR NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) INSULATION (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL
1c 6 20 3.1 4.6 6.7 85 52
1c 10 23 4.1 5.6 7.7 129 72
1c 16 27 5.1 6.7 9.0 188 96
1c 25 32 6.4 8.4 10.7 282 127
1c 35 37 7.8 9.8 12.3 385 157
1c 50 42 9.2 11.5 14.0 540 196
1c 70 48 10.8 13.3 16.0 730 242
1c 95 55 12.8 15.3 18.3 981 293
1c 120 61 14.5 17.3 20.4 1216 339
1c 150 69 16.3 19.5 22.9 1541 389
1c 185 76 18.0 21.7 25.2 1869 444
1c 240 84 20.3 24.2 28.0 2389 522
1c 300 93 22.5 27.2 31.1 2998 601
1c 400 104 26.0 30.7 34.8 3858 690
1c 500 116 29.2 34.4 38.7 4855 720
1c 630 130 32.8 38.4 43.2 6098 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-353IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
IEEE 45IEEE 1580
FLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, USCG, TC Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL2c 1.5 24 8.1 86 202c 2.5 28 9.5 124 262c 4 31 10.3 163 342c 6 35 11.8 223 442c 10 41 13.8 334 612c 16 49 16.2 481 822c 25 59 19.8 745 1082c 35 68 22.7 1008 1333c 1.5 25 8.4 106 163c 2.5 30 10.1 149 213c 4 33 10.9 200 283c 6 37 12.5 276 363c 10 45 14.9 430 503c 16 52 17.4 626 673c 25 63 21.0 959 893c 35 73 24.2 1303 1103c 50 83 27.7 1836 1373c 70 96 32.0 2491 1693c 95 110 36.7 3354 2053c 120 123 41.0 4161 2373c 150 139 46.2 5289 2723c 185 154 51.2 6439 3113c 240 171 57.0 8219 3654c 1.5 28 9.5 126 164c 2.5 33 11.0 180 214c 4 36 12.1 250 284c 6 41 13.6 341 364c 10 49 16.3 535 504c 16 57 19.1 784 674c 25 70 23.3 1215 894c 35 80 26.8 1654 1104c 50 93 31.0 2351 1374c 70 107 35.6 3173 1694c 95 122 40.8 4275 2054c 120 137 45.8 5323 2374c 150 154 51.5 6763 2724c 185 171 57.0 8226 3115c 1.5 31 10.4 162 165c 2.5 37 12.2 235 215c 4 40 13.3 317 285c 6 46 15.2 437 365c 10 55 18.2 680 505c 16 64 21.3 990 675c 25 78 26.1 1526 895c 35 90 30.0 2071 1105c 50 104 34.7 2936 1375c 70 120 40.0 3972 1695c 95 137 45.8 5339 2055c 120 154 51.4 6635 2375c 150 173 57.8 8416 2725c 185 192 64.1 10253 3115c 240 214 71.3 13083 3657c 1.5 34 11.3 179 12
10c 1.5 43 14.3 254 1112c 1.5 44 14.8 293 1014c 1.5 47 15.6 333 1016c 1.5 50 16.7 382 919c 1.5 52 17.5 441 924c 1.5 61 20.5 557 827c 1.5 63 21.1 615 833c 1.5 69 22.9 743 737c 1.5 71 23.8 821 77c 2.5 39 13.1 258 16
10c 2.5 50 16.8 376 1412c 2.5 52 17.5 436 1314c 2.5 55 18.4 497 1216c 2.5 59 19.7 569 1219c 2.5 62 20.8 659 1124c 2.5 73 24.3 833 1027c 2.5 76 25.2 933 1033c 2.5 82 27.2 1116 937c 2.5 85 28.4 1249 9
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 110°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 13
BVFLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
CONDUCTORDIAMETER
(mm)
1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2
10.812.814.516.318.01.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 1470
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 114
MK FLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
CONSTRUCTIONConductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV. Excellent abrasion
resistance.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
NUMBER OF MINIMUM CONDUCTOR NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) INSULATION (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL
1c 6 20 3.1 4.6 6.7 85 52
1c 10 23 4.1 5.6 7.7 129 72
1c 16 27 5.1 6.7 9.0 188 96
1c 25 32 6.4 8.4 10.7 282 127
1c 35 37 7.8 9.8 12.3 385 157
1c 50 42 9.2 11.5 14.0 540 196
1c 70 48 10.8 13.3 16.0 730 242
1c 95 55 12.8 15.3 18.3 981 293
1c 120 61 14.5 17.3 20.4 1216 339
1c 150 69 16.3 19.5 22.9 1541 389
1c 185 76 18.0 21.7 25.2 1869 444
1c 240 84 20.3 24.2 28.0 2389 522
1c 300 93 22.5 27.2 31.1 2998 601
1c 400 104 26.0 30.7 34.8 3858 690
1c 500 116 29.2 34.4 38.7 4855 720
1c 630 130 32.8 38.4 43.2 6098 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, USCG, RAN
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
DEF(AUST) 5000
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 15
MKFLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL2c 1.5 24 8.1 86 202c 2.5 28 9.5 124 262c 4 31 10.3 163 342c 6 35 11.8 223 442c 10 41 13.8 334 612c 16 49 16.2 481 822c 25 59 19.8 745 1082c 35 68 22.7 1008 1333c 1.5 25 8.4 106 163c 2.5 30 10.1 149 213c 4 33 10.9 200 283c 6 37 12.5 276 363c 10 45 14.9 430 503c 16 52 17.4 626 673c 25 63 21.0 959 893c 35 73 24.2 1303 1103c 50 83 27.7 1836 1373c 70 96 32.0 2491 1693c 95 110 36.7 3354 2053c 120 123 41.0 4161 2373c 150 139 46.2 5289 2723c 185 154 51.2 6439 3113c 240 171 57.0 8219 3654c 1.5 28 9.5 126 164c 2.5 33 11.0 180 214c 4 36 12.1 250 284c 6 41 13.6 341 364c 10 49 16.3 535 504c 16 57 19.1 784 674c 25 70 23.3 1215 894c 35 80 26.8 1654 1104c 50 93 31.0 2351 1374c 70 107 35.6 3173 1694c 95 122 40.8 4275 2054c 120 137 45.8 5323 2374c 150 154 51.5 6763 2724c 185 171 57.0 8226 3115c 1.5 31 10.4 162 165c 2.5 37 12.2 235 215c 4 40 13.3 317 285c 6 46 15.2 437 365c 10 55 18.2 680 505c 16 64 21.3 990 675c 25 78 26.1 1526 895c 35 90 30.0 2071 1105c 50 104 34.7 2936 1375c 70 120 40.0 3972 1695c 95 137 45.8 5339 2055c 120 154 51.4 6635 2375c 150 173 57.8 8416 2725c 185 192 64.1 10253 3115c 240 214 71.3 13083 3657c 1.5 34 11.3 179 12
10c 1.5 43 14.3 254 1112c 1.5 44 14.8 293 1014c 1.5 47 15.6 333 1016c 1.5 50 16.7 382 919c 1.5 52 17.5 441 924c 1.5 61 20.5 557 827c 1.5 63 21.1 615 833c 1.5 69 22.9 743 737c 1.5 71 23.8 821 77c 2.5 39 13.1 258 16
10c 2.5 50 16.8 376 1412c 2.5 52 17.5 436 1314c 2.5 55 18.4 497 1216c 2.5 59 19.7 569 1219c 2.5 62 20.8 659 1124c 2.5 73 24.3 833 1027c 2.5 76 25.2 933 1033c 2.5 82 27.2 1116 937c 2.5 85 28.4 1249 9
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 110°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2
10.812.814.516.318.01.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 1470
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 116
DV
CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Separator: Polypropylene Tape
Braid/Armour Options:Tinned Copper Wire Braid (90%)Galvanized Steel Wire Braid (90%)(Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications where
mechanical or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60331
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD BRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS INSULATION BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) (mm) NOMINAL
1c 6 33 4.6 5.4 6.3 8.3 128 52
1c 10 38 5.6 6.5 7.3 9.6 190 72
1c 16 42 6.8 7.6 8.3 10.6 247 96
1c 25 50 8.4 9.2 10.0 12.5 356 127
1c 35 56 9.8 10.7 11.5 14.0 463 157
1c 50 63 11.5 12.3 13.1 15.8 635 196
1c 70 71 13.3 14.1 14.9 17.9 838 242
1c 95 80 15.3 16.2 17.0 20.1 1104 293
1c 120 88 17.3 18.1 18.9 22.0 1343 339
1c 150 98 19.5 20.4 21.2 24.5 1683 389
1c 185 107 21.7 22.5 23.3 26.9 2026 444
1c 240 118 24.2 25.1 25.9 29.6 2602 522
1c 300 129 27.2 28.0 28.3 32.3 3225 601
1c 400 147 30.7 31.5 32.3 36.7 4098 690
1c 500 162 34.4 35.2 36.0 40.5 5113 720
1c 630 180 38.4 39.3 40.1 45.0 6386 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
CONDUCTORDIAMETER
(mm)
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
LR, DNV, ABS, GL, BV, USCG, TC Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 17
DVFLEXIBLE SHIPBOARD BRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL
2c 1.5 40 6.8 7.6 9.9 156 202c 2.5 45 8.0 8.8 11.1 193 262c 4 49 8.9 9.7 12.2 243 342c 6 54 10.2 10.9 13.4 306 442c 10 63 12.2 12.9 15.6 438 612c 16 71 14.5 14.9 17.8 599 822c 25 86 17.7 18.3 21.4 876 1082c 35 97 20.4 21.0 24.3 1154 1333c 1.5 41 7.3 8.1 10.4 168 163c 2.5 48 8.6 9.4 11.9 220 213c 4 51 9.5 10.3 12.8 276 283c 6 57 10.9 11.6 14.3 362 363c 10 66 13.1 13.8 16.5 521 503c 16 75 15.5 15.9 18.8 728 673c 25 91 18.9 19.5 22.9 1088 893c 35 104 21.9 22.5 26.0 1445 1103c 50 118 25.0 25.8 29.6 1990 1373c 70 135 28.9 29.7 33.9 2678 1693c 95 154 33.2 34.0 38.4 3514 2053c 120 172 37.3 38.1 42.9 4344 2373c 150 192 42.0 42.9 48.0 5476 2723c 185 212 46.6 47.4 53.0 6625 3113c 240 235 52.0 52.8 58.8 8398 3654c 1.5 44 8.0 8.8 11.1 187 164c 2.5 51 9.5 10.3 12.8 255 214c 4 55 10.5 11.3 13.8 326 284c 6 62 12.0 12.7 15.4 431 364c 10 72 14.5 15.2 18.1 640 504c 16 83 17.2 17.6 20.7 902 674c 25 100 21.1 21.6 25.0 1343 894c 35 115 24.4 24.9 28.7 1807 1104c 50 131 27.9 28.7 32.7 2529 1374c 70 150 32.2 33.0 37.4 3357 1694c 95 171 37.0 37.9 42.6 4469 2054c 120 190 41.6 42.4 47.6 5525 2374c 150 213 46.9 47.7 53.3 6971 2724c 185 235 52.0 52.8 58.8 8435 3115c 1.5 49 8.9 9.7 12.2 222 165c 2.5 56 10.6 11.4 13.9 298 215c 4 61 11.7 12.5 15.2 392 285c 6 68 13.4 14.1 17.0 521 365c 10 80 16.2 16.9 20.0 777 505c 16 92 19.3 19.6 22.9 1100 675c 25 111 23.6 24.2 27.7 1644 895c 35 127 27.4 27.9 31.8 2244 1105c 50 146 31.3 32.1 36.5 3105 1377c 1.5 52 9.8 10.6 13.1 239 12
10c 1.5 65 12.7 13.5 16.2 329 1112c 1.5 68 13.3 14.1 17.0 379 1014c 1.5 71 14.0 14.8 17.7 423 1016c 1.5 75 14.9 15.7 18.6 469 919c 1.5 79 15.8 16.6 19.7 541 924c 1.5 91 18.6 19.5 22.8 674 927c 1.5 94 19.2 20.1 23.4 735 933c 1.5 101 20.9 21.7 25.2 874 937c 1.5 105 21.8 22.6 26.1 957 97c 2.5 61 11.6 12.5 15.2 334 21
10c 2.5 75 15.1 15.9 18.8 464 2012c 2.5 79 15.8 16.6 19.7 536 1814c 2.5 83 16.7 17.5 20.6 603 1816c 2.5 87 17.8 18.6 21.7 671 1619c 2.5 92 18.9 19.7 23.0 778 1524c 2.5 107 22.3 23.1 26.6 971 1527c 2.5 109 23.0 23.8 27.4 1064 1533c 2.5 118 25.0 25.8 29.6 1270 1537c 2.5 123 26.1 26.9 30.8 1409 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2
10.812.814.516.318.01.52.12.53.14.15.16.47.89.21.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 1470
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705
- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 118
RC
CONSTRUCTIONConductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Screen: Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.5 0.95 7.9 71
2p 0.5 (quad formation) 0.95 8.9 88
4p 0.5 0.95 13.2 135
8p 0.5 0.95 16.6 222
10p 0.5 0.95 18.1 268
12p 0.5 0.95 19.8 318
16p 0.5 0.95 21.6 392
20p 0.5 0.95 22.8 470
24p 0.5 0.95 24.0 540
27p 0.5 0.95 24.9 593
36p 0.5 0.95 28.8 782
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
24
27
40
50
54
59
65
68
72
75
86
LR, DNV, ABS, GL, BV, USCG, TC Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 19
RCFLEXIBLE SHIPBOARD INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.75 1.2 8.4 82 2p 0.75 (quad formation) 1.2 9.5 105 4p 0.75 1.2 14.2 169 6p 0.75 1.2 16.0 223 8p 0.75 1.2 18.3 287
10p 0.75 1.2 19.9 348 12p 0.75 1.2 21.5 402 14p 0.75 1.2 22.7 462 16p 0.75 1.2 23.8 512 20p 0.75 1.2 24.9 606 24p 0.75 1.2 26.4 712 27p 0.75 1.2 27.4 784 36p 0.75 1.2 31.7 1036 1p 1.0 1.3 8.8 95 2p 1.0 (quad formation) 1.3 9.8 118 4p 1.0 1.3 14.9 193 8p 1.0 1.3 18.9 326
10p 1.0 1.3 20.5 396 12p 1.0 1.3 22.2 459 16p 1.0 1.3 24.6 587 20p 1.0 1.3 25.9 709 24p 1.0 1.3 27.3 822 27p 1.0 1.3 28.6 919 36p 1.0 1.3 32.8 1198 1p 1.5 1.5 8.9 107 2p 1.5 (quad formation) 1.5 10.6 147 4p 1.5 1.5 16.3 243 8p 1.5 1.5 20.8 431
10p 1.5 1.5 22.7 525 12p 1.5 1.5 24.6 611 16p 1.5 1.5 27.1 785 20p 1.5 1.5 28.6 951 24p 1.5 1.5 30.1 1108 27p 1.5 1.5 31.5 1240 36p 1.5 1.5 36.4 1637 1p 2.5 2.1 9.5 137 2p 2.5 (quad formation) 2.1 12.3 2104p 2.5 2.1 19.1 350 8p 2.5 2.1 24.8 632
10p 2.5 2.1 26.7 769 12p 2.5 2.1 29.2 913 16p 2.5 2.1 32.2 1176 20p 2.5 2.1 34.0 1430 24p 2.5 2.1 35.8 1671 27p 2.5 2.1 37.5 1870 36p 2.5 2.1 43.3 2470
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1t 0.75 1.2 9.0 94 3t 0.75 1.2 13.4 170 4t 0.75 1.2 14.8 216 7t 0.75 1.2 17.9 338 1t 1.5 1.5 9.9 128 3t 1.5 1.5 15.2 255 4t 1.5 1.5 16.6 317 7t 1.5 1.5 20.4 518
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
25284348556064687175798295262945576167747882869827324962687481869094
10928375774808897
102107112130
MINIMUMBENDINGRADIUS
(mm)
2740445430465061
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 120
RS
CONSTRUCTIONConductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Screen: Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where
mechanical or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD COLLECTIVESCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 5.7 6.6 9.1 129
2p 0.5 (quad form) 0.95 6.5 7.4 9.9 141
4p 0.5 0.95 10.5 11.5 14.2 201
8p 0.5 0.95 13.6 14.7 17.6 307
10p 0.5 0.95 14.9 16.0 18.9 353
12p 0.5 0.95 16.3 17.5 20.6 410
16p 0.5 0.95 18.1 19.3 22.6 504
20p 0.5 0.95 19.1 20.3 23.6 577
24p 0.5 0.95 20.5 21.7 25.3 668
27p 0.5 0.95 21.6 22.9 26.4 729
36p 0.5 0.95 24.6 25.9 29.7 958
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
36
40
57
71
76
82
91
95
101
106
119
LR, DNV, ABS, GL, BV, USCG,
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 21
RSFLEXIBLE SHIPBOARD COLLECTIVESCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 6.2 7.4 10.0 146 3t 0.75 1.2 9.9 11.2 14.4 237 4t 0.75 1.2 11.0 12.3 15.6 281 7t 0.75 1.2 13.6 14.9 18.7 419 1t 1.5 1.5 7.6 8.8 10.9 178 3t 1.5 1.5 12.5 13.8 16.1 321 4t 1.5 1.5 13.9 15.1 17.6 398 7t 1.5 1.5 17.2 18.5 21.2 608
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 5.8 7.1 9.6 141 2p 0.75 (quad form) 1.2 6.7 8.0 10.5 159 4p 0.75 1.2 10.5 12.3 15.0 234 8p 0.75 1.2 14.0 16.2 19.1 372
10p 0.75 1.2 15.3 17.6 20.7 441 12p 0.75 1.2 16.8 19.2 22.6 51314p 0.75 1.2 17.6 20.2 23.5 56916p 0.75 1.2 18.6 21.3 24.6 62520p 0.75 1.2 19.6 22.4 25.9 736 24p 0.75 1.2 21.0 23.9 27.5 842 27p 0.75 1.2 22.2 25.2 29.0 980 36p 0.75 1.2 25.2 28.6 32.5 1217 1p 1.0 1.3 6.0 7.3 9.8 151 2p 1.0 (quad form) 1.3 6.9 8.3 10.6 168 4p 1.0 1.3 11.2 13.0 15.7 261 8p 1.0 1.3 14.6 16.8 19.9 423
10p 1.0 1.3 15.9 18.2 21.4 493 12p 1.0 1.3 17.5 19.9 23.3 575 16p 1.0 1.3 19.4 22.1 25.6 715 20p 1.0 1.3 20.4 23.2 26.7 833 24p 1.0 1.3 21.9 24.8 28.6 1012 27p 1.0 1.3 23.1 26.2 29.9 1100 36p 1.0 1.3 26.3 29.7 33.8 1391 1p 1.5 1.5 7.1 7.9 10.4 170 2p 1.5 (quad form) 1.5 8.2 9.0 11.5 203 4p 1.5 1.5 13.5 14.3 17.2 325 8p 1.5 1.5 17.7 18.5 21.6 529
10p 1.5 1.5 19.3 20.2 23.5 631 12p 1.5 1.5 21.2 22.0 25.6 739 16p 1.5 1.5 23.6 24.4 28.2 927 20p 1.5 1.5 24.9 25.7 29.4 1089 24p 1.5 1.5 26.7 27.5 31.4 1301 27p 1.5 1.5 28.2 29.0 32.9 1423 36p 1.5 1.5 32.1 32.9 37.3 1817 1p 2.5 2.1 8.3 9.2 11.7 213 2p 2.5 (quad form) 2.1 9.7 10.5 13.0 269 4p 2.5 2.1 16.1 16.9 20.0 447 8p 2.5 2.1 21.2 22.0 25.5 757
10p 2.5 2.1 23.2 24.0 27.5 896 12p 2.5 2.1 25.4 26.3 30.0 1052 16p 2.5 2.1 28.3 29.1 33.1 1331 20p 2.5 2.1 29.8 30.7 34.8 1608 24p 2.5 2.1 32.0 32.8 37.2 1873 27p 2.5 2.1 33.8 34.6 39.2 2081 36p 2.5 2.1 38.5 39.3 44.1 2682
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
3842607683909498
104110116130394263808593
1021071141201354246698794
102113118126132149475280
102110120132139149157176
MINIMUMBENDINGRADIUS
(mm)
4058627544647185
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 122
EW
CONSTRUCTIONConductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Screen: Individual and Collective
Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.5 0.95 7.9 69
2p 0.5 0.95 12.4 132
4p 0.5 0.95 14.7 180
8p 0.5 0.95 18.6 303
10p 0.5 0.95 20.3 367
12p 0.5 0.95 21.9 425
16p 0.5 0.95 24.2 543
20p 0.5 0.95 25.5 654
24p 0.5 0.95 27.1 759
27p 0.5 0.95 28.6 852
36p 0.5 0.95 32.3 1102
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
24
37
44
56
61
66
73
76
81
86
119
LR, DNV, ABS, GL, BV, USCG, TC
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 23
EWFLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.75 1.2 8.4 80 2p 0.75 1.2 13.2 153 4p 0.75 1.2 15.8 212 8p 0.75 1.2 20.2 372
10p 0.75 1.2 21.8 442 12p 0.75 1.2 23.8 524 16p 0.75 1.2 26.4 671 20p 0.75 1.2 27.6 798 24p 0.75 1.2 29.5 943 27p 0.75 1.2 31.2 1057 36p 0.75 1.2 35.1 1371 1p 1.0 1.3 8.8 93 2p 1.0 1.3 13.6 172 4p 1.0 1.3 16.2 244 8p 1.0 1.3 20.8 433
10p 1.0 1.3 22.7 528 12p 1.0 1.3 24.5 614 16p 1.0 1.3 27.2 789 20p 1.0 1.3 28.6 957 24p 1.0 1.3 30.4 1117 27p 1.0 1.3 32.1 1252 36p 1.0 1.3 36.4 1646 1p 1.5 1.5 9.4 111 2p 1.5 1.5 14.8 211 4p 1.5 1.5 17.4 301 5p 1.5 1.5 18.7 356 8p 1.5 1.5 22.8 543
10p 1.5 1.5 24.6 651 12p 1.5 1.5 26.9 773 16p 1.5 1.5 29.7 995 20p 1.5 1.5 31.3 1209 24p 1.5 1.5 33.5 1430 27p 1.5 1.5 35.2 1587 36p 1.5 1.5 39.9 2087 1p 2.5 2.1 10.6 148 2p 2.5 2.1 17.1 288 4p 2.5 2.1 20.5 423 8p 2.5 2.1 26.5 765
10p 2.5 2.1 28.9 936 12p 2.5 2.1 31.5 1110 16p 2.5 2.1 34.8 1434 20p 2.5 2.1 36.7 1745 24p 2.5 2.1 39.2 2066 27p 2.5 2.1 41.2 2297 36p 2.5 2.1 46.7 3022
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL1t 0.75 1.2 8.3 90 3t 0.75 1.2 13.6 208 4t 0.75 1.2 15.0 257 7t 0.75 1.2 18.1 406 1t 1.5 1.5 9.9 127 3t 1.5 1.5 16.4 308 4t 1.5 1.5 18.1 3947t 1.5 1.5 21.9 633
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
25404761657179838894
10526414962687382869296
109284452566874818994
101106120325161798794
104110118124140
MINIMUMBENDINGRADIUS
(mm)2541455430495466
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 124
EG
CONSTRUCTIONConductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Screen: Individual and Collective
Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Braid/Armour Options:
Tinned Copper Wire Braid (90%)
Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS\
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where
mechanical or EMC protection is required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 6.0 6.9 9.2 129
2p 0.5 0.95 10.0 11.0 13.5 239
4p 0.5 0.95 12.1 13.1 15.8 249
8p 0.5 0.95 15.6 16.8 19.9 398
10p 0.5 0.95 17.1 18.3 21.4 462
12p 0.5 0.95 18.7 19.9 23.2 538
16p 0.5 0.95 20.8 22.0 25.5 667
20p 0.5 0.95 21.9 23.1 26.6 772
24p 0.5 0.95 23.4 24.7 28.4 896
27p 0.5 0.95 24.7 26.0 29.7 982
36p 0.5 0.95 28.1 29.4 33.6 1265
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
37
54
63
80
85
93
102
107
114
119
134
LR, DNV, ABS, GL, BV, USCG,
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 25
EGFLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 5.0 7.8 10.1 141 3t 0.75 1.2 10.5 13.2 15.9 277 4t 0.75 1.2 11.7 14.5 17.4 340 7t 0.75 1.2 14.6 17.7 20.8 505 1t 1.5 1.5 6.4 8.7 11.0 170 3t 1.5 1.5 13.1 14.8 17.7 380 4t 1.5 1.5 14.6 16.3 19.3 463 7t 1.5 1.5 18.2 19.9 23.3 719
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 6.5 7.4 9.7 142 2p 0.75 1.2 10.8 11.9 14.6 289 4p 0.75 1.2 13.1 14.2 17.1 294 8p 0.75 1.2 17.1 18.2 21.3 467
10p 0.75 1.2 18.7 19.8 23.2 556 12p 0.75 1.2 20.4 21.6 25.0 637 16p 0.75 1.2 22.7 24.0 27.5 795 20p 0.75 1.2 23.9 25.2 28.9 940 24p 0.75 1.2 25.6 26.9 30.9 1094 27p 0.75 1.2 27.0 28.4 32.3 1227 36p 0.75 1.2 30.7 32.1 36.5 1549 1p 1.0 1.3 6.7 7.6 9.9 155 2p 1.0 1.3 11.2 12.2 14.9 318 4p 1.0 1.3 13.5 14.6 17.5 329 8p 1.0 1.3 17.6 18.8 21.9 532
10p 1.0 1.3 19.3 20.5 23.8 635 12p 1.0 1.3 21.1 22.3 25.9 742 16p 1.0 1.3 23.5 24.7 28.5 930 20p 1.0 1.3 24.7 26.0 29.7 1090 24p 1.0 1.3 26.5 27.8 31.7 1273 27p 1.0 1.3 27.9 29.3 33.2 1402 36p 1.0 1.3 31.7 33.2 37.5 1814 1p 1.5 1.5 7.3 8.2 10.5 174 2p 1.5 1.5 12.2 13.2 15.9 380 4p 1.5 1.5 14.8 15.9 18.8 387 8p 1.5 1.5 19.4 20.6 23.9 651
10p 1.5 1.5 21.2 22.4 25.9 779 12p 1.5 1.5 23.2 24.5 28.2 913 16p 1.5 1.5 25.8 27.1 31.0 1150 20p 1.5 1.5 27.1 28.5 32.4 1357 24p 1.5 1.5 29.1 30.5 34.6 1587 27p 1.5 1.5 30.7 32.1 36.5 1777 36p 1.5 1.5 34.9 36.4 41.0 2274 1p 2.5 2.1 8.5 9.5 12.0 219 2p 2.5 2.1 14.2 15.3 18.2 522 4p 2.5 2.1 17.3 18.5 21.6 520 8p 2.5 2.1 22.8 24.0 27.6 831
10p 2.5 2.1 24.9 26.2 30.0 100212p 2.5 2.1 27.3 28.7 32.6 117816p 2.5 2.1 30.4 31.8 36.0 1600 20p 2.5 2.1 32.0 33.4 37.8 1920 24p 2.5 2.1 34.3 35.8 40.4 2253 27p 2.5 2.1 36.2 37.8 42.5 2512 36p 2.5 2.1 41.2 42.8 48.0 3265
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
3958688593
1001101161231291464060708895
10411411912713315042647596
104113124130138146164487386
110120130144151161170192
MINIMUMBENDINGRADIUS
(mm)
4063708344717793
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 126
RR
CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications, where
circuit integrity is required under fire conditions
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-353IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
FLEXIBLE SHIPBOARDFIRE RESISTANT POWER AND CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS INSULATION (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) NOMINAL
1c 6 37 5.4 7.5 101 52
1c 10 43 6.4 8.7 151 72
1c 16 49 7.5 9.8 211 96
1c 25 58 9.1 11.6 315 127
1c 35 65 10.6 13.1 417 157
1c 50 74 12.2 14.9 583 196
1c 70 85 14.0 17.0 779 242
1c 95 95 16.1 19.0 1029 293
1c 120 105 18.0 21.1 1272 339
1c 150 118 20.3 23.6 1603 389
1c 185 130 22.4 26.0 1938 444
1c 240 143 25.0 28.7 2466 522
1c 300 159 27.9 31.9 3093 601
1c 400 178 31.4 35.6 3955 690
1c 500 198 35.1 39.7 4981 720
1c 630 219 39.2 43.9 6219 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45IEEE 1580
CONDUCTORDIAMETER
(mm)
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 27
RRFLEXIBLE SHIPBOARDFIRE RESISTANT POWER AND CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL
2c 1.5 48 9.7 121 202c 2.5 55 11.0 163 262c 4 60 12.0 211 342c 6 66 13.2 271 442c 10 77 15.5 400 612c 16 89 17.8 563 822c 25 106 21.2 829 1082c 35 121 24.2 1105 1333c 1.5 49 9.9 143 163c 2.5 59 11.8 200 213c 4 63 12.7 256 283c 6 71 14.2 341 363c 10 82 16.4 502 503c 16 95 19.0 714 673c 25 114 22.8 1072 893c 35 129 25.9 1435 1103c 50 147 29.5 1987 1373c 70 169 33.8 2666 1693c 95 191 38.3 3539 2053c 120 214 42.8 4391 2373c 150 240 48.0 5548 2723c 185 264 52.9 6724 3113c 240 293 58.7 8537 3654c 1.5 55 11.1 171 164c 2.5 64 12.9 241 214c 4 69 13.9 313 284c 6 78 15.6 420 364c 10 91 18.2 631 504c 16 105 21.1 901 674c 25 126 25.3 1354 894c 35 144 28.8 1816 1104c 50 164 32.8 2524 1374c 70 187 37.5 3389 1694c 95 213 42.7 4525 2054c 120 238 47.7 5609 2374c 150 267 53.4 7083 2724c 185 294 58.9 8580 3115c 1.5 62 12.4 209 165c 2.5 72 14.4 294 215c 4 77 15.5 383 285c 6 87 17.4 513 365c 10 102 20.4 773 505c 16 117 23.5 1105 675c 25 141 28.2 1660 895c 35 176 32.2 2228 1105c 50 184 36.8 3118 1377c 1.5 67 13.5 241 12
10c 1.5 87 17.5 352 1112c 1.5 91 18.2 406 1014c 1.5 95 19.1 463 1016c 1.5 102 20.4 529 919c 1.5 107 21.5 612 924c 1.5 127 25.4 785 927c 1.5 131 26.2 866 933c 1.5 142 28.4 1046 937c 1.5 147 29.5 1156 97c 2.5 78 15.7 344 21
10c 2.5 101 20.3 498 2012c 2.5 105 21.1 578 1814c 2.5 111 22.2 660 1816c 2.5 118 23.7 754 1619c 2.5 126 25.3 887 1524c 2.5 148 29.6 1119 1527c 2.5 152 30.5 1239 1533c 2.5 165 33.0 1497 1537c 2.5 173 34.6 1674 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2
10.812.814.516.318.01.52.12.53.14.15.16.47.89.21.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 1470
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705
- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 128
BH
CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Separator: Polypropylene Tape
Braid/Armour Options:Tinned Copper Wire Braid (90%) Galvanized Steel Wire Braid (90%)(Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-353IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
FLEXIBLE SHIPBOARD FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS INSULATION BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) (mm) NOMINAL
1c 6 46 5.4 6.2 7.0 9.3 162 52
1c 10 52 6.4 7.2 8.0 10.3 210 72
1c 16 58 7.5 8.3 9.1 11.6 279 96
1c 25 66 9.1 10.0 10.8 13.3 388 127
1c 35 75 10.6 11.4 12.2 14.9 506 157
1c 50 83 12.2 13.0 13.8 16.5 676 196
1c 70 93 14.0 14.9 15.7 18.6 885 242
1c 95 104 16.1 16.9 17.7 20.8 1158 293
1c 120 115 18.0 18.8 19.1 23.0 1414 339
1c 150 127 20.3 21.1 21.9 25.4 1762 389
1c 185 138 22.4 23.2 24.1 27.6 2099 444
1c 240 152 25.0 25.8 26.6 30.3 2644 522
1c 300 165 27.9 28.8 29.1 33.0 3287 601
1c 400 187 31.4 32.2 33.0 37.4 4192 690
1c 500 206 35.1 35.9 36.7 41.3 5226 720
1c 630 229 39.2 40.0 40.8 45.8 6512 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45IEEE 1580
CONDUCTORDIAMETER
(mm)
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 29
BHFLEXIBLE SHIPBOARD FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL
2c 1.5 57 8.2 9.0 11.5 196 20
2c 2.5 64 9.5 10.3 12.8 248 26
2c 4 68 10.3 11.1 13.6 296 34
2c 6 75 11.5 12.4 15.1 371 44
2c 10 87 13.6 14.4 17.3 514 61
2c 16 97 15.8 16.6 19.5 683 82
2c 25 115 18.9 19.7 23.1 978 108
2c 35 130 21.6 22.5 26.0 1271 133
3c 1.5 60 8.7 9.5 12.0 215 16
3c 2.5 67 10.2 110 13.5 275 21
3c 4 73 11.0 11.8 14.6 343 28
3c 6 79 12.3 13.2 15.9 430 36
3c 10 91 14.5 15.4 18.3 609 50
3c 16 104 16.9 17.7 20.8 834 67
3c 25 122 20.3 21.1 24.4 1197 89
3c 35 138 23.2 24.0 27.6 1571 110
3c 50 157 26.6 27.4 31.3 2147 137
3c 70 177 30.4 31.3 35.4 2834 169
3c 95 201 34.8 35.6 40.1 3719 205
3c 120 223 38.8 39.7 44.6 4576 237
3c 150 248 43.6 44.4 49.6 5713 272
3c 185 273 48.1 48.9 54.5 6885 311
3c 240 302 53.5 54.3 60.3 8825 365
4c 1.5 65 9.6 10.5 13.0 247 16
4c 2.5 74 11.2 12.1 14.8 328 21
4c 4 79 12.2 13.0 15.7 405 28
4c 6 87 13.7 14.5 17.4 521 36
4c 10 100 16.1 17.0 20.1 746 50
4c 16 114 18.8 19.6 22.9 1030 67
4c 25 135 22.6 23.4 26.9 1489 89
4c 35 152 25.9 26.7 30.4 1963 110
4c 50 173 29.6 30.4 34.6 2715 137
4c 70 197 34.0 34.8 39.3 3575 169
4c 95 223 38.8 39.6 44.6 4723 205
4c 120 247 43.4 44.2 49.4 5791 237
4c 150 275 48.7 49.5 55.1 7268 272
4c 185 303 53.7 54.5 60.6 8761 311
5c 1.5 71 10.8 11.6 14.3 294 16
5c 2.5 80 12.5 13.4 16.1 385 21
5c 4 87 13.6 14.5 17.4 487 28
5c 6 95 15.3 16.1 19.0 620 36
5c 10 110 18.1 18.9 22.0 896 50
5c 16 127 21.0 21.8 25.4 1256 67
5c 25 149 25.3 26.1 29.9 1822 89
5c 35 170 29.0 29.9 34.0 2441 110
5c 50 192 33.3 34.1 38.5 3318 137
7c 1.5 77 11.9 12.7 15.4 319 12
12c 1.5 100 16.1 16.9 20.0 509 10
19c 1.5 117 19.2 20.0 23.4 733 9
24c 1.5 135 22.7 23.5 27.1 915 9
27c 1.5 140 23.5 24.3 28.0 1012 9
33c 1.5 150 25.5 26.3 30.0 1191 9
37c 1.5 157 26.6 27.4 31.3 1320 9
7c 2.5 90 13.8 15.1 18.0 436 21
12c 2.5 117 18.8 20.1 23.4 700 18
19c 2.5 136 22.5 23.8 27.3 1020 15
24c 2.5 159 26.7 27.9 31.8 1288 15
27c 2.5 163 27.5 28.8 32.7 1412 15
33c 2.5 176 29.9 31.1 35.3 1686 15
37c 2.5 184 31.2 32.4 36.8 1870 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.1
2.1
2.1
2.1
2.1
2.1
2.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 130
ES
CONSTRUCTIONConductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Separator: Polypropylene Tape
Screen: Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-376IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
IEEE 45IEEE 1580
FLEXIBLE SHIPBOARD FIRE RESISTANTCOLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.5 0.95 9.5 104
2p 0.5 (quad formation) 0.95 10.7 128
4p 0.5 0.95 16.5 206
8p 0.5 0.95 21.2 359
10p 0.5 0.95 23.1 435
12p 0.5 0.95 25.2 514
16p 0.5 0.95 27.7 641
20p 0.5 0.95 29.2 771
24p 0.5 0.95 31.2 908
27p 0.5 0.95 32.8 1002
36p 0.5 0.95 37.2 1312
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
47
53
82
106
115
126
138
145
156
164
186
LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 31
ESFLEXIBLE SHIPBOARD FIRE RESISTANTCOLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.75 1.2 10.1 118 2p 0.75 (quad formation) 1.2 11.5 154 4p 0.75 1.2 17.5 249 6p 0.75 1.2 20.0 342 8p 0.75 1.2 22.9 440
10p 0.75 1.2 24.7 523 12p 0.75 1.2 27.0 620 14p 0.75 1.2 28.5 711 16p 0.75 1.2 29.8 792 20p 0.75 1.2 31.5 955 24p 0.75 1.2 33.7 1126 27p 0.75 1.2 35.3 1245 36p 0.75 1.2 40.1 1633 1p 1.0 1.3 10.3 129 2p 1.0 (quad formation) 1.3 11.7 169 4p 1.0 1.3 18.2 275 8p 1.0 1.3 23.5 485
10p 1.0 1.3 25.5 589 12p 1.0 1.3 27.7 685 16p 1.0 1.3 30.8 892 20p 1.0 1.3 32.3 1061 24p 1.0 1.3 34.6 1252 27p 1.0 1.3 36.5 1403 36p 1.0 1.3 41.1 1819 1p 1.5 1.5 10.8 147 2p 1.5 (quad formation) 1.5 12.4 198 4p 1.5 1.5 19.3 328 8p 1.5 1.5 24.9 589
10p 1.5 1.5 27.1 718 12p 1.5 1.5 29.7 852 16p 1.5 1.5 32.8 1094 20p 1.5 1.5 34.6 1327 24p 1.5 1.5 37.0 1568 27p 1.5 1.5 39.0 175636p 1.5 1.5 44.0 2284 1p 2.5 2.1 12.3 199 2p 2.5 (quad formation) 2.1 13.9 267 4p 2.5 2.1 22.5 466 8p 2.5 2.1 29.1 840
10p 2.5 2.1 31.7 1025 12p 2.5 2.1 34.6 1216 16p 2.5 2.1 38.3 1567 20p 2.5 2.1 40.4 1904 24p 2.5 2.1 43.2 2252 27p 2.5 2.1 45.6 2522 36p 2.5 2.1 51.6 3311
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1t 0.75 1.2 10.6 131 3t 0.75 1.2 16.5 254 4t 0.75 1.2 18.3 324 7t 0.75 1.2 22.2 513 1t 1.5 1.5 11.5 172 3t 1.5 1.5 18.2 348 4t 1.5 1.5 20.1 444 7t 1.5 1.5 24.4 714
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
505787
100114123135142149157168176200515891
117127138154161173182205546296
1241351481641731851952206169
112145158173191202216228258
MINIMUMBENDINGRADIUS
(mm)
538391
1115791
100122
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 132
FJ
CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Separator: Polypropylene Tape
Drain Wire: Tinned annealed copper
Screen: Aluminium/Laminate Tape
Separator: Polypropylene Tape
Braid/Armour Options:Tinned Copper Wire Braid (90%)Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where circuitintegrity is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60331-1
IEC 60331-21
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD FIRE RESISTANT COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 7.3 8.1 10.5 156
2p 0.5 (quad form) 0.95 8.4 9.2 11.7 185
4p 0.5 0.95 13.8 14.6 17.5 290
8p 0.5 0.95 18.1 18.9 22.0 458
10p 0.5 0.95 19.8 20.6 23.9 543
12p 0.5 0.95 21.7 22.5 26.1 634
16p 0.5 0.95 24.2 25.0 28.7 786
20p 0.5 0.95 25.5 26.3 30.0 911
24p 0.5 0.95 27.3 28.1 32.1 1058
27p 0.5 0.95 28.8 29.6 33.8 1085
36p 0.5 0.95 32.8 33.6 38.0 1384
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
52
58
88
110
120
130
143
150
160
169
190
LR, DNV, ABS, GL, BV, USCG, TC
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 33
FJFLEXIBLE SHIPBOARD FIRE RESISTANT COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 8.1 9.1 11.6 180 3t 0.75 1.2 13.6 14.6 17.6 337 4t 0.75 1.2 15.1 16.2 19.1 407 7t 0.75 1.2 18.7 19.9 23.2 625 1t 1.5 1.5 8.9 9.9 12.4 217 3t 1.5 1.5 15.0 16.1 19.0 428 4t 1.5 1.5 16.6 17.8 20.9 533 7t 1.5 1.5 20.6 21.9 25.4 834
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 7.6 8.6 10.9 173 2p 0.75 (quad form) 1.2 8.8 9.8 12.3 210 4p 0.75 1.2 14.3 15.4 18.3 330 8p 0.75 1.2 19.2 20.4 23.7 548
10p 0.75 1.2 21.0 22.2 25.7 651 12p 0.75 1.2 23.0 24.3 28.0 761 14p 0.75 1.2 24.2 25.5 29.3 847 16p 0.75 1.2 25.6 26.9 30.9 871 20p 0.75 1.2 27.0 28.3 32.3 1023 24p 0.75 1.2 28.9 30.3 34.5 1193 27p 0.75 1.2 30.6 32.0 36.4 1329 36p 0.75 1.2 34.8 36.3 40.9 1828 1p 1.0 1.3 7.8 8.8 11.1 184 2p 1.0 (quad form) 1.3 9.1 10.1 12.6 226 4p 1.0 1.3 15.0 16.1 19.0 360 8p 1.0 1.3 19.7 20.9 24.3 596
10p 1.0 1.3 21.6 22.8 26.4 711 12p 1.0 1.3 23.7 25.0 28.7 831 16p 1.0 1.3 26.3 27.7 31.6 1039 20p 1.0 1.3 27.8 29.2 33.1 1218 24p 1.0 1.3 29.8 31.2 35.4 1420 27p 1.0 1.3 31.5 32.9 37.3 1580 36p 1.0 1.3 35.8 37.4 42.2 2040 1p 1.5 1.5 8.3 9.3 11.8 208 2p 1.5 (quad form) 1.5 9.7 10.7 13.2 259 4p 1.5 1.5 16.1 17.2 20.3 428 8p 1.5 1.5 21.2 22.4 25.9 719
10p 1.5 1.5 23.2 24.4 28.2 860 12p 1.5 1.5 25.4 26.7 30.5 918 16p 1.5 1.5 28.3 29.7 33.8 1268 20p 1.5 1.5 29.8 31.2 35.4 1495 24p 1.5 1.5 32.0 33.4 37.8 1749 27p 1.5 1.5 33.8 35.3 39.9 1948 36p 1.5 1.5 38.5 40.1 45.1 2523 1p 2.5 2.1 9.6 10.6 13.1 263 2p 2.5 (quad form) 2.1 11.2 12.3 15.0 344 4p 2.5 2.1 18.8 20.0 23.3 572 8p 2.5 2.1 24.9 26.2 29.9 980
10p 2.5 2.1 27.2 28.6 32.5 1094 12p 2.5 2.1 29.9 31.3 35.5 1384 16p 2.5 2.1 33.3 34.7 39.3 1771 20p 2.5 2.1 35.1 36.6 41.2 2103 24p 2.5 2.1 37.6 39.2 44.0 2466 27p 2.5 2.1 39.8 41.4 46.4 2748 36p 2.5 2.1 45.3 47.0 52.4 3571
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
546291
118129140146154161172182204556395
1211321441581661771862115966
1021301411521691771891992256675
117150163177197206220232262
MINIMUMBENDINGRADIUS
(mm)
588895
1166295
104127
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 134
FC
CONSTRUCTIONConductor: Finely stranded tinned annealed
copper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free,
Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
Separator: Polypropylene Tape
Screen: Individual and Collective
Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic,
Flame Retardant, Low Smoke, Zero Halogen
(SHF-1 to IEC 60092-359) Splash resistant to
oil, skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where
circuit integrity is required under fire conditions.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-376IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
FLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.5 0.95 9.5 101
2p 0.5 0.95 15.1 188
4p 0.5 0.95 18.0 257
8p 0.5 0.95 23.2 451
10p 0.5 0.95 25.3 547
12p 0.5 0.95 27.4 635
16p 0.5 0.95 30.3 812
20p 0.5 0.95 31.9 979
24p 0.5 0.95 34.1 1155
27p 0.5 0.95 35.8 1277
36p 0.5 0.95 40.6 1674
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
47
75
90
116
126
137
151
159
170
194
203
LR, DNV, ABS, GL, BV, USCG,Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 35
FCFLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL
1p 0.75 1.2 10.1 115 2p 0.75 1.2 15.9 213 4p 0.75 1.2 19.1 296 8p 0.75 1.2 24.6 525
10p 0.75 1.2 26.9 640 12p 0.75 1.2 29.3 758 16p 0.75 1.2 32.4 971 20p 0.75 1.2 34.2 1173 24p 0.75 1.2 36.5 1383 27p 0.75 1.2 38.4 1532 36p 0.75 1.2 43.5 2009 1p 1.0 1.3 10.3 125 2p 1.0 1.3 16.3 234 4p 1.0 1.3 19.7 339 8p 1.0 1.3 25.4 603
10p 1.0 1.3 27.5 722 12p 1.0 1.3 30.0 856 16p 1.0 1.3 32.2 1100 20p 1.0 1.3 35.0 1333 24p 1.0 1.3 37.4 1574 27p 1.0 1.3 39.5 1763 36p 1.0 1.3 44.8 2313 1p 1.5 1.5 10.8 143 2p 1.5 1.5 17.3 275 4p 1.5 1.5 20.5 392 8p 1.5 1.5 26.9 710
10p 1.5 1.5 29.3 867 12p 1.5 1.5 32.0 1028 16p 1.5 1.5 35.4 1324 20p 1.5 1.5 37.3 1608 24p 1.5 1.5 39.9 1901 27p 1.5 1.5 42.1 2130 36p 1.5 1.5 47.7 2795 1p 2.5 2.1 12.3 193 2p 2.5 2.1 19.8 367 4p 2.5 2.1 23.8 536 8p 2.5 2.1 31.1 988
10p 2.5 2.1 33.9 1206 12p 2.5 2.1 37.0 1431 16p 2.5 2.1 40.9 1846 20p 2.5 2.1 43.0 2246 24p 2.5 2.1 46.0 2658 27p 2.5 2.1 48.6 2976 36p 2.5 2.1 55.0 3910
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT
X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL1t 0.75 1.2 10.6 125 3t 0.75 1.2 17.9 296 4t 0.75 1.2 19.8 377 7t 0.75 1.2 23.9 599 1t 1.5 1.5 11.5 164 3t 1.5 1.5 19.3 391 4t 1.5 1.5 21.4 502 7t 1.5 1.5 26.1 822
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
507995
123134146162171182192216518198
1271371501611751871972245486
1021341461601771861992102386198
119155169185204215230243275
MINIMUMBENDINGRADIUS
(mm)538999
1195796
107130
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 136
FL
CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Separator: Polypropylene Tape
Drain Wire: Tinned annealed copper
Screen: Individual and CollectiveAluminium/Laminate Tape
Separator: Polypropylene Tape
Braid/Armour Options:Tinned Copper Wire Braid (90%) Galvanized Steel Wire Braid (90%)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where circuit
integrity is required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60331-1
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
FLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 7.3 8.1 10.4 156
2p 0.5 0.95 12.7 13.5 16.2 340
4p 0.5 0.95 15.4 16.2 19.1 341
8p 0.5 0.95 20.2 21.0 24.3 559
10p 0.5 0.95 22.0 22.8 26.4 665
12p 0.5 0.95 24.1 24.9 28.7 775
16p 0.5 0.95 26.8 27.6 31.6 965
20p 0.5 0.95 28.3 29.1 33.0 1125
24p 0.5 0.95 30.3 31.1 35.2 1309
27p 0.5 0.95 32.0 32.8 37.1 1465
36p 0.5 0.95 36.4 37.2 41.9 1876
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
52
81
96
121
132
143
158
165
176
186
210
LR, DNV, ABS, GL, BV, USCG,
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 37
FLFLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 8.5 9.6 12.1 193 3t 0.75 1.2 15.4 16.7 19.8 419 4t 0.75 1.2 17.2 18.4 21.5 506 7t 0.75 1.2 21.1 22.5 26.0 776 1t 1.5 1.5 9.3 10.4 12.9 233 3t 1.5 1.5 16.8 18.1 21.2 522 4t 1.5 1.5 18.7 20.0 23.3 650 7t 1.5 1.5 23.1 24.5 28.2 1012
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 7.5 8.6 10.9 171 2p 0.75 1.2 13.2 14.3 17.2 398 4p 0.75 1.2 16.0 17.3 20.4 395 8p 0.75 1.2 21.1 22.4 25.9 653
10p 0.75 1.2 23.1 24.4 28.2 778 12p 0.75 1.2 25.3 26.7 30.4 895 16p 0.75 1.2 28.1 29.6 33.8 1137 20p 0.75 1.2 29.6 31.1 35.3 1331 24p 0.75 1.2 31.7 33.3 37.7 1552 27p 0.75 1.2 33.5 35.1 39.7 1726 36p 0.75 1.2 38.1 39.8 44.8 2227 1p 1.0 1.3 7.7 8.8 11.1 182 2p 1.0 1.3 13.5 14.7 17.6 431 4p 1.0 1.3 16.5 17.7 20.8 432 8p 1.0 1.3 21.6 23.0 26.5 723
10p 1.0 1.3 23.7 25.1 28.8 864 12p 1.0 1.3 26.0 27.4 31.1 1011 16p 1.0 1.3 28.9 30.4 34.5 1270 20p 1.0 1.3 30.4 31.9 36.3 1511 24p 1.0 1.3 32.6 34.2 38.5 1747 27p 1.0 1.3 34.4 36.1 40.6 1945 36p 1.0 1.3 39.2 40.9 45.9 2516 1p 1.5 1.5 8.2 9.3 11.8 209 2p 1.5 1.5 14.3 15.5 18.4 492 4p 1.5 1.5 17.5 18.8 21.9 493 8p 1.5 1.5 23.1 24.5 28.2 850
10p 1.5 1.5 25.3 26.7 30.4 1005 12p 1.5 1.5 27.7 29.2 33.1 1179 16p 1.5 1.5 30.8 32.3 36.7 1517 20p 1.5 1.5 32.5 34.0 38.4 1781 24p 1.5 1.5 34.8 36.4 41.0 2085 27p 1.5 1.5 36.8 38.4 43.2 2323 36p 1.5 1.5 41.8 43.6 48.8 3012 1p 2.5 2.1 9.5 10.6 13.1 264 2p 2.5 2.1 16.5 17.8 20.9 664 4p 2.5 2.1 20.2 21.6 24.9 648 8p 2.5 2.1 26.8 28.2 32.2 1134
10p 2.5 2.1 29.3 30.8 35.0 1366 12p 2.5 2.1 32.2 33.7 38.1 1604 16p 2.5 2.1 35.8 37.4 42.2 1056 20p 2.5 2.1 37.7 39.4 44.2 2446 24p 2.5 2.1 40.5 42.2 47.4 2892 27p 2.5 2.1 42.7 44.5 49.7 3201 36p 2.5 2.1 48.7 50.6 56.4 4186
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
5486
1021301411521691761881982245588
1041331441571731821932032295992
11014115216618419220521624466
104124161175190211221237248282
MINIMUMBENDINGRADIUS
(mm)
6099
10813064
106117141
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 138
FLEXIBLE SHOREPOWER0.6/1kV 110°C
EZ
CONSTRUCTIONConductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30 (X-HF-110)
Cross-linked, Thermoset, Elastomeric,
Flame Retardant, Low Smoke, Zero Halogen
Splash resistant to oil, skydrol, petrol, acid,
sea water. Resists ozone and UV.
Ripcord: High strength ripcord under jacket
Jacket: E-Rubber®N-40, Elastomeric Rubber,
Splash resistant to oil, skydrol, petrol, acid,
sea water. Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPLICATIONFlexible Shorepower cables suitable for all shipboard and marine applications.
AS/NZS 1125
AS/NZS 5000.1
AS/NZS 3191
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL
2c 1.5 27 9.1 105 28
2c 2.5 32 10.8 151 38
2c 4 35 11.8 197 50
2c 6 40 13.2 261 63
2c 10 52 17.5 460 88
2c 16 60 19.9 633 116
2c 25 72 24.1 950 154
2c 35 82 27.5 1265 190
*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed spaced) 110°C operating temperature, 40°C ambient temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
FLEXIBLE SHOREPOWER0.6/1kV 110°C
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 39
EZ
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL
3c 1.5 29 9.8 126 24
3c 2.5 34 11.3 177 32
3c 4 37 12.4 236 42
3c 6 42 14.1 324 54
3c 10 56 18.6 564 75
3c 16 63 21.1 788 99
3c 25 77 25.6 1187 131
3c 35 87 29.1 1588 162
3c 50 100 33.3 2203 204
3c 70 114 38.0 2943 255
3c 95 130 43.4 3925 306
3c 120 145 48.3 4857 360
3c 150 162 54.1 6138 413
3c 185 179 59.6 7451 470
3c 240 199 66.3 9454 599
3c 300 218 72.7 11788 638
4c 1.5 32 10.7 153 24
4c 2.5 37 12.4 216 32
4c 4 41 13.8 296 42
4c 6 47 15.7 406 54
4c 10 61 20.4 698 75
4c 16 70 23.2 980 99
4c 25 85 28.3 1491 131
4c 35 97 32.2 1996 162
4c 50 110 36.8 2774 204
4c 70 127 42.2 3727 255
4c 95 144 48.0 4967 306
4c 120 161 53.6 6164 360
4c 150 181 60.2 7808 413
4c 185 199 66.3 9462 470
4c 240 221 73.8 12038 559
4c 300 242 80.8 15015 638
5c 1.5 35 11.8 191 24
5c 2.5 42 13.9 275 32
5c 4 46 15.2 367 42
5c 6 52 17.3 501 54
5c 10 67 22.6 852 75
5c 16 77 25.6 1208 99
5c 25 94 31.2 1832 131
5c 35 107 35.8 2466 162
5c 50 123 41.1 3441 204
*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed spaced) 110°C operating temperature, 40°C ambient temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
UP
CONSTRUCTIONConductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Single Insulated Power Cables suitable for all shipboard and marine applications
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 140
FLEXIBLE SHIPBOARDSWITCHBOARD/PANEL WIRE0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL
1c 0.75 7 2.6 13 16
1c 1.0 7 2.7 15 20
1c 1.5 7 2.9 20 26
1c 2.5 9 3.5 30 32
1c 4 10 3.9 44 43
1c 6 11 4.5 63 52
1c 10 14 5.6 99 72
1c 16 16 6.6 150 96
1c 25 21 8.3 236 127
1c 35 24 9.7 326 157
1c 50 28 11.3 471 196
1c 70 33 13.1 637 242
1c 95 38 15.2 865 293
1c 120 43 17.1 1076 339
1c 150 48 19.3 1370 389
1c 185 54 21.4 1667 444
1c 240 60 23.9 2040 522
1c 300 66 26.4 2654 601
1c 400 76 30.3 3509 690
1c 500 85 33.9 4439 720
1c 630 95 38.0 5585 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.2
1.3
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -
- - -
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, RAN, USCG,
OFFSHORE CABLES
POWER AND CONTROL
Braided/Armoured PJ 42
INSTRUMENTATION
Collective screened
Braided/Armoured RB 44
Individual and collective screened
Braided/Armoured FZ 46
POWER AND CONTROL – F i re Resistant
Braided/Armoured HT 48
INSTRUMENTATION – F i re Resistant
Collective screened
Braided/Armoured FK 50
Individual and collective screened
Braided/Armoured FE 52
SWITCHBOARD/PANEL WIRE UP 54
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 142
PJ
CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Ripcord: High strength ripcord under bedding in multicores
Bedding: LSFLEX®S-50 Low Smoke, Zero Halogen (pressure extruded)
Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all offshore applications, where mechanical
or EMC protection is required.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-353IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE BRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL
1c 10 44 7.8 8.6 11.1 210 72
1c 16 49 8.8 9.6 12.3 281 96
1c 25 58 10.7 11.5 14.4 401 127
1c 35 63 12.1 12.9 15.9 512 157
1c 50 72 13.9 14.7 17.9 696 196
1c 70 80 15.7 16.5 20.0 905 242
1c 95 89 17.9 18.7 22.2 1176 293
1c 120 97 19.8 20.6 24.3 1431 339
1c 150 108 22.2 23.0 27.0 1789 389
1c 185 118 24.5 25.3 29.6 2150 444
1c 240 130 27.2 28.0 32.5 2708 522
1c 300 141 30.3 30.4 35.2 3355 601
1c 400 160 33.9 34.7 40.0 4292 690
1c 500 176 37.7 38.5 44.1 5348 720
1c 630 195 42.0 42.8 48.8 6659 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45IEEE 1580
CONDUCTORDIAMETER
(mm)
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 43
PJFLEXIBLE OFFSHOREBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL2c 1.5 46 8.1 8.9 11.6 169 202c 2.5 51 9.3 10.1 12.8 211 262c 4 55 10.3 11.1 13.9 260 342c 6 61 11.5 12.3 15.3 328 442c 10 71 13.7 14.5 17.7 464 612c 16 80 15.7 16.5 19.9 623 822c 25 95 19.2 20.0 23.7 901 1082c 35 107 22.1 22.9 26.8 1182 1333c 1.5 48 8.6 9.4 12.1 190 163c 2.5 53 9.9 10.7 13.4 243 213c 4 59 10.9 11.7 14.7 311 283c 6 64 12.2 13.0 16.0 392 363c 10 74 14.6 15.4 18.6 567 503c 16 84 16.6 17.4 20.9 776 673c 25 102 20.6 21.4 25.4 1158 893c 35 115 23.7 24.5 28.7 1529 1103c 50 130 27.2 28.0 32.5 2090 1373c 70 148 31.2 32.0 37.0 2784 1693c 95 168 35.6 36.4 41.9 3672 2053c 120 186 39.8 40.6 46.4 4506 2373c 150 208 44.9 45.7 52.0 5680 2723c 185 229 49.5 50.3 57.2 6857 3113c 240 253 55.2 56.0 62.4 8682 3654c 1.5 51 9.3 10.1 12.8 218 164c 2.5 59 10.9 11.7 14.7 293 214c 4 63 11.9 12.7 15.7 366 284c 6 69 13.3 14.1 17.3 475 364c 10 81 15.9 16.7 20.2 694 504c 16 92 18.5 19.3 23.0 968 674c 25 110 22.7 23.5 27.5 1427 894c 35 126 26.1 26.9 31.5 1909 1104c 50 142 30.4 30.8 35.6 2639 1374c 70 163 34.7 35.5 40.7 3514 1694c 95 185 39.6 40.4 46.2 4656 2054c 120 206 44.5 45.3 51.6 5759 2374c 150 230 49.9 50.7 57.5 7240 2724c 185 254 55.3 56.1 63.4 8762 3115c 1.5 56 10.4 11.2 13.9 254 165c 2.5 63 12.0 12.8 15.8 338 215c 4 68 13.1 13.9 17.1 434 285c 6 76 14.9 15.7 18.9 563 365c 10 88 17.8 18.6 22.1 830 505c 16 102 20.6 21.4 25.4 1175 675c 25 122 25.4 26.2 30.4 1736 895c 35 139 29.2 30.0 34.8 2325 1105c 50 159 33.8 34.6 39.8 3238 1375c 70 181 38.8 39.6 45.4 4313 1695c 95 206 44.5 45.3 51.6 5735 2055c 120 230 49.8 50.6 57.4 7069 2375c 150 258 56.0 56.8 64.4 8938 2725c 185 284 62.0 62.8 70.9 10809 3115c 240 315 69.1 69.9 78.8 13734 3657c 1.5 62 11.3 12.5 15.4 341 12
10c 1.5 75 14.3 15.5 18.7 462 1112c 1.5 77 14.8 16.0 19.3 511 1014c 1.5 81 15.6 16.8 20.2 572 1016c 1.5 85 16.5 17.7 21.1 626 919c 1.5 89 17.5 18.7 22.2 708 921c 1.5 94 18.6 19.8 23.5 777 924c 1.5 103 20.5 21.7 25.7 889 927c 1.5 105 21.1 22.3 26.3 958 933c 1.5 113 22.7 23.9 28.2 1119 937c 1.5 117 23.8 25.0 29.3 1224 97c 2.5 70 13.1 14.3 17.5 452 21
10c 2.5 85 16.6 17.8 21.3 617 2012c 2.5 89 17.5 18.7 22.2 697 1814c 2.5 93 18.4 19.6 23.3 783 1816c 2.5 98 19.5 20.7 24.4 863 1619c 2.5 104 20.8 22.0 25.9 993 1521c 2.5 109 22.0 23.2 27.2 1077 1524c 2.5 119 24.3 25.5 29.8 1231 1527c 2.5 122 25.0 26.2 30.5 1335 1533c 2.5 132 27.2 28.4 32.9 1579 1537c 2.5 137 28.2 29.4 34.2 1735 15
CONDUCTORDIAMETER
(mm)
1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2
10.812.814.516.318.01.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.12.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 1470
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 144
RB
CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Separator: Polypropylene Tape
Screen: Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under bedding
Bedding: LSFLEX®S-50 Low Smoke, Zero Halogen (pressure extruded)
Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where mechanical or
EMC protection is required.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-376IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE COLLECTIVE SCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 7.8 8.7 11.2 146
2p 0.5(quad form) 0.95 8.6 9.5 12.2 173
4p 0.5 0.95 12.9 13.8 16.9 278
8p 0.5 0.95 16.2 17.1 20.6 404
10p 0.5 0.95 17.6 18.5 22.0 463
12p 0.5 0.95 19.1 20.0 23.7 528
16p 0.5 0.95 21.1 22.0 26.0 640
20p 0.5 0.95 22.1 23.0 27.0 719
24p 0.5 0.95 23.7 24.6 28.8 827
27p 0.5 0.95 24.8 25.7 30.0 894
36p 0.5 0.95 28.0 28.9 33.6 1129
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
45
49
68
82
88
95
104
108
115
120
134
LR, DNV, ABS, GL, BV, USCG, RAN
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 45
RBFLEXIBLE OFFSHORE COLLECTIVE SCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 8.7 9.6 12.3 178 3t 0.75 1.2 13.0 13.9 17.1 315 4t 0.75 1.2 14.4 15.3 18.5 372 7t 0.75 1.2 17.4 18.3 21.8 530 1t 1.5 1.5 9.6 10.5 13.2 217 3t 1.5 1.5 14.8 15.7 19.0 415 4t 1.5 1.5 16.2 17.1 20.6 500 7t 1.5 1.5 19.7 20.6 24.3 734
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 8.3 9.2 11.9 166 2p 0.75(quad form) 1.2 9.2 10.1 12.8 195 4p 0.75 1.2 14.1 15.0 18.2 325 8p 0.75 1.2 17.8 18.7 22.2 483
10p 0.75 1.2 19.2 20.1 23.8 560 12p 0.75 1.2 21.0 21.9 25.9 650 16p 0.75 1.2 23.0 23.9 28.1 78420p 0.75 1.2 24.3 25.2 29.5 899 24p 0.75 1.2 25.8 26.7 31.2 1027 27p 0.75 1.2 27.3 28.2 32.7 1126 36p 0.75 1.2 30.8 31.7 36.7 1427 1p 1.0 1.3 8.7 9.4 12.1 177 2p 1.0(quad form) 1.3 9.7 10.4 13.1 210 4p 1.0 1.3 15.0 15.4 18.7 350 8p 1.0 1.3 19.0 19.3 23.0 539
10p 1.0 1.3 20.7 20.7 24.5 615 12p 1.0 1.3 22.4 22.6 26.6 715 16p 1.0 1.3 24.8 24.9 29.1 877 20p 1.0 1.3 25.9 26.0 30.3 1000 24p 1.0 1.3 27.8 27.8 32.3 115727p 1.0 1.3 29.2 29.1 33.9 1274 36p 1.0 1.3 32.9 32.8 37.8 1602 1p 1.5 1.5 9.1 10.0 12.7 198 2p 1.5(quad form) 1.5 10.4 11.3 14.2 254 4p 1.5 1.5 15.8 16.7 20.1 421 8p 1.5 1.5 20.3 21.2 25.0 660
10p 1.5 1.5 21.9 22.8 26.8 772 12p 1.5 1.5 24.0 24.9 29.1 900 16p 1.5 1.5 26.3 27.2 31.7 1102 20p 1.5 1.5 27.8 28.7 33.2 1281 24p 1.5 1.5 29.5 30.4 35.2 1475 27p 1.5 1.5 31.2 32.1 37.1 1651 36p 1.5 1.5 35.2 36.1 41.4 2077 1p 2.5 2.1 10.5 11.4 14.4 255 2p 2.5(quad form) 2.1 11.8 12.7 15.7 321 4p 2.5 2.1 18.5 19.4 23.1 563 8p 2.5 2.1 23.9 24.8 29.1 919
10p 2.5 2.1 25.9 26.8 31.4 1081 12p 2.5 2.1 28.3 29.2 33.9 1263 16p 2.5 2.1 31.3 32.2 37.2 1681 20p 2.5 2.1 32.8 33.7 38.8 1829 24p 2.5 2.1 35.2 36.1 41.3 2130 27p 2.5 2.1 37.1 38.0 43.6 2370 36p 2.5 2.1 41.9 42.8 48.9 3040
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
4851738995
1041131181251311474852759298
106116121129135151515781
100107116127133141148166576393
116125136149155165174195
MINIMUMBENDINGRADIUS
(mm)
4969748753768297
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 146
FZ
CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Separator: Polypropylene Tape
Screen: Individual and CollectiveAluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under bedding
Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)
Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%)(Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where mechanical orEMC protection is required.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-376IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 7.8 8.7 11.2 164
2p 0.5 0.95 12.0 12.9 15.9 273
4p 0.5 0.95 14.3 15.2 18.4 321
8p 0.5 0.95 18.1 19.0 22.7 476
10p 0.5 0.95 19.6 20.5 24.2 558
12p 0.5 0.95 21.4 22.3 26.2 647
16p 0.5 0.95 23.6 24.5 28.8 813
20p 0.5 0.95 24.7 25.6 29.9 929
24p 0.5 0.95 26.3 27.2 31.7 1043
27p 0.5 0.95 27.8 28.7 33.2 1133
36p 0.5 0.95 31.3 32.2 37.2 1388
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
45
64
74
91
97
105
115
119
127
133
149
LR, DNV, ABS, GL, BV, USCG, RAN
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 47
FZFLEXIBLE OFFSHORE INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 9.4 9.6 12.3 179 3t 0.75 1.2 15.7 15.3 18.5 351 4t 0.75 1.2 17.4 16.6 20.0 417 7t 0.75 1.2 21.0 19.9 23.6 603 1t 1.5 1.5 10.1 10.5 13.2 233 3t 1.5 1.5 17.0 16.9 20.3 496 4t 1.5 1.5 18.8 18.6 22.1 605 7t 1.5 1.5 22.7 22.3 26.3 890
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 8.3 9.2 11.9 167 2p 0.75 1.2 12.9 13.8 17.0 311 4p 0.75 1.2 15.4 16.3 19.7 370 8p 0.75 1.2 19.5 20.4 24.2 566
10p 0.75 1.2 21.3 22.2 26.2 649 12p 0.75 1.2 23.1 24.0 28.2 805 16p 0.75 1.2 25.5 26.4 30.9 960 20p 0.75 1.2 26.9 27.8 32.3 1087 24p 0.75 1.2 28.6 29.5 34.3 1230 27p 0.75 1.2 30.3 31.2 35.9 1384 36p 0.75 1.2 34.2 35.1 40.3 1692 1p 1.0 1.3 8.5 9.4 12.1 178 2p 1.0 1.3 13.2 14.1 17.3 337 4p 1.0 1.3 15.5 16.4 19.8 401 8p 1.0 1.3 20.3 21.2 25.0 633
10p 1.0 1.3 21.9 22.8 26.8 746 12p 1.0 1.3 24.0 24.9 29.1 897 16p 1.0 1.3 26.3 27.2 31.7 108020p 1.0 1.3 27.8 28.7 33.2 1241 24p 1.0 1.3 29.5 30.4 35.2 1422 27p 1.0 1.3 31.2 32.1 37.1 1548 36p 1.0 1.3 35.2 36.1 41.4 1972 1p 1.5 1.5 9.1 10.0 12.7 212 2p 1.5 1.5 14.4 15.3 18.6 435 4p 1.5 1.5 17.3 18.2 21.6 515 8p 1.5 1.5 22.0 22.9 26.9 818
10p 1.5 1.5 24.0 24.9 29.2 1004 12p 1.5 1.5 26.0 26.9 31.4 115716p 1.5 1.5 28.8 29.7 34.5 1386 20p 1.5 1.5 30.4 31.3 36.3 1634 24p 1.5 1.5 32.3 33.2 38.3 1873 27p 1.5 1.5 34.2 35.1 40.3 2080 36p 1.5 1.5 38.6 39.5 45.2 2658 1p 2.5 2.1 10.5 11.4 14.4 269 2p 2.5 2.1 16.5 17.4 20.8 561 4p 2.5 2.1 19.8 20.7 24.4 661 8p 2.5 2.1 25.6 26.5 31.0 1115
10p 2.5 2.1 28.0 28.9 33.6 1306 12p 2.5 2.1 30.6 31.5 36.5 1522 16p 2.5 2.1 33.8 34.7 40.0 1903 20p 2.5 2.1 35.5 36.4 41.9 2242 24p 2.5 2.1 38.0 38.9 44.6 2612 27p 2.5 2.1 39.9 40.8 46.6 2874 36p 2.5 2.1 45.3 46.2 52.5 3723
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
48687997
105113124129137144161486979
100107116127133141148166517487
108117126138145153161181578398
124134146160167178186210
MINIMUMBENDINGRADIUS
(mm)
49748094538188
105
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 148
HT
CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Ripcord: High strength ripcord under bedding
Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)
Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacketin multicores
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Power and Control cables suitable for all offshore applications, where circuit integrityis required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6
IEC 60228IEC 60092-350 IEC 60092-353IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL
1c 10 60 8.4 9.3 12.0 241 72
1c 16 66 9.5 10.4 13.1 311 96
1c 25 76 11.3 12.2 15.2 435 127
1c 35 83 12.7 13.6 16.6 561 157
1c 50 93 14.5 15.4 18.6 739 196
1c 70 103 16.3 17.2 20.7 955 242
1c 95 116 18.5 19.4 23.1 1242 293
1c 120 127 20.6 21.5 25.5 1514 339
1c 150 139 22.8 23.7 27.7 1859 389
1c 185 152 25.1 26.0 30.3 2226 444
1c 240 166 27.8 28.7 33.3 2684 522
1c 300 182 30.5 31.4 36.3 3419 601
1c 400 204 34.6 35.5 40.7 4397 670
1c 500 225 38.4 39.3 45.0 5484 720
1c 630 248 42.6 43.5 49.5 6789 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
CONDUCTORDIAMETER
(mm)
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
LR, DNV, ABS, GL, BV, USCG,
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 49
HTFLEXIBLE OFFSHORE FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)
AREA (mm2) (mm) (mm) (mm) NOMINAL2c 1.5 65 9.4 10.3 13.0 209 202c 2.5 74 10.9 11.8 14.7 270 262c 4 78 11.7 12.6 15.5 317 342c 6 85 12.9 13.8 17.0 392 442c 10 96 15.1 16.0 19.2 530 612c 16 109 17.4 18.3 21.8 711 822c 25 128 20.7 21.6 25.6 1009 1082c 35 144 23.6 24.5 28.7 1305 1333c 1.5 68 9.9 10.8 13.5 237 163c 2.5 77 11.5 12.4 15.4 311 213c 4 81 12.4 13.3 16.2 373 283c 6 90 13.9 14.8 18.0 474 363c 10 102 16.0 16.9 20.4 657 503c 16 116 18.5 19,4 23.1 893 673c 25 135 22.1 23.0 26.9 1269 893c 35 151 25.1 26.0 30.3 1657 1103c 50 171 28.6 29.5 34.3 2251 1373c 70 193 32.6 33.5 39.2 2943 1693c 95 218 37.2 38.1 43.7 3876 2053c 120 242 41.5 42.4 48.4 4758 2373c 150 269 46.3 47.2 53.8 5943 2723c 185 296 51.2 52.1 59.1 7165 3113c 240 327 56.8 57.7 65.3 8695 3654c 1.5 74 11.0 11.9 14.9 286 164c 2.5 82 12.6 13.5 16.4 363 214c 4 89 13.7 14.6 17.8 455 284c 6 97 15.2 16.1 19.3 566 364c 10 111 17.8 18.7 22.2 802 504c 16 127 20.3 21.4 25.4 1110 674c 25 148 24.5 25.4 29.4 1587 894c 35 168 27.9 28.8 33.6 2094 1104c 50 189 31.8 32.7 37.7 2837 1374c 70 213 36.3 37.2 42.7 3740 1694c 95 242 41.4 42.3 48.3 4931 2054c 120 268 46.1 47.0 53.5 6054 2374c 150 298 51.7 52.6 59.7 7588 2724c 185 328 57.1 58.0 65.6 9144 3115c 1.5 80 12.1 13.0 16.0 328 165c 2.5 91 14.1 15.0 18.2 434 215c 4 96 15.1 16.0 19.3 530 285c 6 107 17.0 17.9 21.3 681 365c 10 121 19.7 20.6 24.3 961 505c 16 138 22.8 23.7 27.7 1323 675c 25 164 27.4 28.3 32.8 1928 895c 35 186 31.2 32.1 37.1 2557 1105c 50 210 35.6 36.5 42.0 3479 1375c 70 239 40.8 41.7 47.7 4603 1695c 95 269 46.3 47.2 53.8 6051 2055c 120 299 51.8 52.7 59.8 7447 2375c 150 334 58.1 59.0 66.8 9360 2725c 185 367 64.1 65.0 73.3 11271 3115c 240 406 71.1 72.0 81.1 13702 3657c 1.5 86 13.2 14.1 17.3 387 12
10c 1.5 107 17.0 17.9 21.4 539 1112c 1.5 111 17.7 18.6 22.1 601 1014c 1.5 116 18.6 19.5 23.2 676 1016c 1.5 122 19.7 20.6 24.4 745 919c 1.5 129 21.0 21.9 25.9 859 921c 1.5 136 22.3 23.2 27.2 931 924c 1.5 149 24.6 25.5 29.8 1068 927c 1.5 154 25.4 26.3 30.7 1170 933c 1.5 165 27.5 28.4 33.0 1370 937c 1.5 171 28.6 29.5 34.3 1506 97c 2.5 97 15.3 16.2 19.5 508 21
10c 2.5 121 19.6 20.5 24.2 712 2012c 2.5 127 20.6 21.5 25.5 821 1814c 2.5 133 21.7 22.6 26.6 914 1816c 2.5 140 23.0 23.9 28.1 1023 1619c 2.5 148 24.5 25.4 29.6 1168 1521c 2.5 157 25.9 26.8 31.3 1284 1524c 2.5 172 28.7 29.6 34.3 1471 1527c 2.5 176 29.6 30.5 35.2 1616 1533c 2.5 190 32.1 33.0 38.0 1898 1537c 2.5 199 33.6 34.5 39.7 2104 15
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2
10.812.814.516.318.01.52.12.53.14.15.16.47.89.2
10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.12.1
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 1470
- - -- - -- - -
84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990
1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905
- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 150
FK
CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Separator: Polypropylene Tape
Screen: Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Ripcord: High strength ripcord under bedding
Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)
Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where circuit integrity isrequired under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60331-1
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE FIRE RESISTANTCOLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 9.3 10.2 12.9 189
2p 0.5(quad form) 0.95 10.6 11.5 14.4 236
4p 0.5 0.95 16.1 17.0 20.4 387
8p 0.5 0.95 20.7 21.6 25.6 603
10p 0.5 0.95 22.4 23.3 27.3 686
12p 0.5 0.95 24.4 25.3 29.6 797
16p 0.5 0.95 27.0 27.9 32.4 974
20p 0.5 0.95 28.3 29.2 34.0 1121
24p 0.5 0.95 30.3 31.2 36.0 1277
27p 0.5 0.95 31.8 32.7 37.7 1404
36p 0.5 0.95 35.9 36.8 42.4 1778
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
64
72
102
128
136
148
162
170
180
189
212
LR, DNV, ABS, GL, BV, USCG,
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 51
FKFLEXIBLE OFFSHORE FIRE RESISTANTCOLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 10.5 11.4 14.3 236 3t 0.75 1.2 16.1 17.0 20.5 435 4t 0.75 1.2 17.8 18.7 22.2 519 7t 0.75 1.2 21.6 22.5 26.5 766 1t 1.5 1.5 11.2 12.1 15.1 277 3t 1.5 1.5 17.7 18.6 22.1 542 4t 1.5 1.5 19.4 20.3 24.0 657 7t 1.5 1.5 23.8 24.7 28.9 999
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 9.8 10.7 13.4 206 2p 0.75 (quad form) 1.2 11.2 12.1 15.0 262 4p 0.75 1.2 17.3 18.2 21.7 442 8p 0.75 1.2 22.1 23.0 27.0 690
10p 0.75 1.2 24.1 25.0 29.3 813 12p 0.75 1.2 26.2 27.1 31.6 935 16p 0.75 1.2 28.9 29.8 34.6 1149 20p 0.75 1.2 30.5 31.4 36.4 1343 24p 0.75 1.2 32.5 33.4 38.4 1522 27p 0.75 1.2 34.3 35.2 40.5 1690 36p 0.75 1.2 38.8 39.7 45.4 2148 1p 1.0 1.3 10.2 11.1 13.8 223 2p 1.0 (quad form) 1.3 11.4 12.3 15.3 278 4p 1.0 1.3 17.8 18.7 22.1 471 8p 1.0 1.3 22.7 23.6 27.6 741
10p 1.0 1.3 24.7 25.6 29.9 876 12p 1.0 1.3 27.1 28.0 32.5 1019 16p 1.0 1.3 29.7 30.6 35.4 1244 20p 1.0 1.3 31.4 32.3 37.3 1459 24p 1.0 1.3 33.6 34.5 39.7 1689 27p 1.0 1.3 35.3 36.2 41.4 1843 36p 1.0 1.3 39.8 40.7 46.5 2348 1p 1.5 1.5 10.7 11.6 14.5 250 2p 1.5 (quad form) 1.5 12.0 12.9 15.9 311 4p 1.5 1.5 18.8 19.7 23.4 545 8p 1.5 1.5 24.3 25.2 29.5 882
10p 1.5 1.5 26.3 27.2 31.7 1035 12p 1.5 1.5 28.8 29.7 34.4 1208 16p 1.5 1.5 31.8 32.7 37.8 1498 20p 1.5 1.5 33.6 34.5 39.8 1764 24p 1.5 1.5 35.8 36.7 42.2 2034 27p 1.5 1.5 37.8 38.7 44.2 2241 36p 1.5 1.5 42.7 43.6 49.6 2865 1p 2.5 2.1 12.0 12.9 15.8 303 2p 2.5 (quad form) 2.1 13.8 14.7 17.9 404 4p 2.5 2.1 21.7 22.6 26.6 712 8p 2.5 2.1 281 29.1 33.9 1190
10p 2.5 2.1 30.8 31.7 36.7 1416 12p 2.5 2.1 33.7 34.6 39.8 1653 16p 2.5 2.1 37.2 38.1 43.7 2061 20p 2.5 2.1 39.1 40.0 45.7 2424 24p 2.5 2.1 41.8 42.7 48.8 2822 27p 2.5 2.1 44.2 45.1 51.3 3139 36p 2.5 2.1 49.9 50.8 57.6 4024
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
6775
1091351461581731821922032276976
1111381491621771861992072337379
1171471591721891992112212487989
133169183199218229244257288
MINIMUMBENDINGRADIUS
(mm)
7110211113375
111120145
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 152
FE
CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.
Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape
Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.
Separator: Polypropylene Tape
Screen: Individual and CollectiveAluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Separator: Polypropylene Tape
Ripcord: High strength ripcord under bedding
Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)
Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING250 Volts
CORE COLOURSTo customer specification
JACKET COLOURTo customer specification
STANDARDS
APPROVALS
APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where circuit integrityis required under fire conditions and mechanical or EMC protection is also required.
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-376
IEC 60331-1
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
NEK 606
FLEXIBLE OFFSHORE FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.5 0.95 9.3 10.7 12.9 189
2p 0.5 0.95 14.7 15.6 18.8 379
4p 0.5 0.95 17.5 18.4 21.9 449
8p 0.5 0.95 22.4 23.3 27.3 701
10p 0.5 0.95 24.5 25.4 29.6 828
12p 0.5 0.95 26.5 27.4 31.9 951
16p 0.5 0.95 29.4 30.3 35.0 1170
20p 0.5 0.95 31.0 31.9 36.8 1378
24p 0.5 0.95 32.9 33.8 39.1 1567
27p 0.5 0.95 34.8 35.7 41.0 1722
36p 0.5 0.95 39.3 40.2 46.0 2188
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
IEEE 45
IEEE 1580
MINIMUMBENDINGRADIUS
(mm)
64
94
110
137
148
160
175
184
195
205
230
LR, DNV, ABS, GL, BV, USCG,
Transport Canada Marine Safety
“Cable constructions, Jackets, and Inner
components tested to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)”
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 53
FEFLEXIBLE OFFSHORE FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1t 0.75 1.2 10.5 11.4 14.3 236 3t 0.75 1.2 17.4 18.4 21.8 487 4t 0.75 1.2 19.1 20.0 23.7 586 7t 0.75 1.2 23.2 24.1 28.3 869 1t 1.5 1.5 11.2 12.1 15.1 277 3t 1.5 1.5 18.8 19.7 23.4 606 4t 1.5 1.5 20.9 21.8 25.7 746 7t 1.5 1.5 25.3 26.2 30.5 1110
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT
X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL
1p 0.75 1.2 9.8 10.7 13.4 206 2p 0.75 1.2 15.5 16.4 19.9 432 4p 0.75 1.2 18.6 19.5 23.2 509 8p 0.75 1.2 24.0 24.9 29.2 813
10p 0.75 1.2 26.0 26.9 31.4 951 12p 0.75 1.2 28.4 29.3 34.1 1106 16p 0.75 1.2 31.4 32.4 37.4 1365 20p 0.75 1.2 33.0 33.9 39.1 1586 24p 0.75 1.2 35.3 36.2 41.5 1818 27p 0.75 1.2 37.3 38.2 43.7 2020 36p 0.75 1.2 42.1 43.0 49.1 2573 1p 1.0 1.3 10.2 11.1 13.8 223 2p 1.0 1.3 15.8 16.7 20.2 461 4p 1.0 1.3 18.7 19.6 23.3 543 8p 1.0 1.3 24.6 25.5 29.8 886
10p 1.0 1.3 26.9 27.8 32.3 1051 12p 1.0 1.3 29.1 30.0 34.8 1212 16p 1.0 1.3 32.3 33.2 38.2 1503 20p 1.0 1.3 34.0 34.9 40.2 1768 24p 1.0 1.3 36.2 37.1 42.6 2038 27p 1.0 1.3 38.2 39.1 44.9 2265 36p 1.0 1.3 43.2 44.1 50.3 2892 1p 1.5 1.5 10.7 11.6 14.5 251 2p 1.5 1.5 16.9 17.8 21.3 523 4p 1.5 1.5 20.3 21.2 24.9 622 8p 1.5 1.5 26.0 26.9 31.4 1022
10p 1.5 1.5 28.4 29.3 34.1 1215 12p 1.5 1.5 31.1 32.0 37.0 1428 16p 1.5 1.5 34.4 35.3 40.6 1765 20p 1.5 1.5 36.0 36.9 42.4 2070 24p 1.5 1.5 38.6 39.5 45.2 2407 27p 1.5 1.5 40.7 41.6 47.6 2677 36p 1.5 1.5 46.0 46.9 53.5 3426 1p 2.5 2.1 12.0 12.9 15.8 304 2p 2.5 2.1 19.1 20.0 23.7 674 4p 2.5 2.1 23.0 23.9 28.1 805 8p 2.5 2.1 30.1 31.0 35.8 1351
10p 2.5 2.1 32.7 33.6 38.6 1599 12p 2.5 2.1 35.7 36.6 42.1 1889 16p 2.5 2.1 38.6 40.5 46.3 2364 20p 2.5 2.1 41.7 42.6 48.6 2805 24p 2.5 2.1 44.6 45.5 51.8 3269 27p 2.5 2.1 47.1 48.0 54.6 363636p 2.5 2.1 53.4 54.3 61.7 4717
Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time
MINIMUMBENDINGRADIUS
(mm)
6799
11614615717018719620821924569
10111714916117419120121322425273
10612515717018520321222623826779
118141179193211231243259273308
MINIMUMBENDINGRADIUS
(mm)
7110911914175
117129152
UP
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 154
CONSTRUCTIONConductor: Finely stranded annealed copper
to IEC 60228 Class 5&6 & AS/NZS 1125.
Available in plain or tinned.
Insulation: LSFLEX®R-30, Cross-linked,
Polyolefinic, Thermoset, Flame Retardant,
Low Smoke, Zero Halogen (HF-90 to
IEC 60092-351) Splash resistant to oil,
skydrol, petrol, acid, sea water.
Resists ozone and UV.
OPERATING TEMP-40°C to +110°C
VOLTAGE RATING600/1000 Volts
CORE COLOURSTo customer specification
STANDARDS
APPROVALSLR, DNV, ABS, GL, BV, USCG, RAN
APPLICATIONFlexible Single Insulated Power Cables suitable for all shipboard and marine applications
AS/NZS 1125
AS/NZS 1660.5.1
AS/NZS 1660.5.2
AS/NZS 1660.5.3
AS/NZS 1660.5.6
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3-22
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
FLEXIBLE OFFSHORE SWITCHBOARD/PANEL WIRE0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%
NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)
AREA (mm2) (mm) NOMINAL
1c 0.75 7 2.6 13 16
1c 1.0 7 2.7 15 20
1c 1.5 7 2.9 20 26
1c 2.5 9 3.5 30 32
1c 4 10 3.9 44 43
1c 6 11 4.5 63 52
1c 10 14 5.6 99 72
1c 16 16 6.6 150 96
1c 25 21 8.3 236 127
1c 35 24 9.7 326 157
1c 50 28 11.3 471 196
1c 70 33 13.1 637 242
1c 95 38 15.2 865 293
1c 120 43 17.1 1076 339
1c 150 48 19.3 1370 389
1c 185 54 21.4 1667 444
1c 240 60 23.9 2040 522
1c 300 66 26.4 2654 601
1c 400 76 30.3 3509 690
1c 500 85 33.9 4439 720
1c 630 95 38.0 5585 780
*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time
CONDUCTORDIAMETER
(mm)
1.2
1.3
1.5
2.1
2.5
3.1
4.1
5.1
6.4
7.8
9.2
10.8
12.8
14.5
16.3
18.0
20.3
22.5
26.0
29.2
32.8
APPROX. NUMBEROF WIRES
TRIANGLE CLASS 5 CLASS 6
- - -
- - -
- - -
- - -
- - -
84 84 192
144 80 320
224 128 512
350 200 800
490 280 1120
707 400 705
991 356 990
1344 485 1340
1692 614 1690
2124 765 2123
2584 994 1470
3344 1125 1905
4144 1530 2385
5488 2035 3200
6944 1768 4010
8736 3200 5020
TECHNICALINFORMATION
Product Coding 56
Lugging Recommendation 57
Installation Recommendation 58
Conductor Data 59
Current Carrying Capacities/ MUD Fluid Immersion Tests 60
Fire Performance Testing 61
Ripcord Technology 62
Drum Handling Procedures 63
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 156
PRODUCT CODING
1. PRODUCT SERIES
eg. (PJ series)
2. JACKET TYPE (Shipboard/Offshore Cables only)
A = SHF-1
C = SHF-2
M = SHF-2 Mud
3. CORE COLOUR CONFIGURATION
eg. SEE COLOUR CODES BELOW
4. BRAID/ARMOUR
A= Aluminum Braid / Overbraid Armor
B= Bronze Braid / Overbraid Armor
E= Polyester + drain wire + Tinned Copper
Wire Braid
F= Tinned Copper Wire Braid + Aluminum
Overbraid Armor
G= Galvanized Steel Wire Braid
K= Bare Copper Wire Braid + drain wire
L= Tinned Copper Wire Braid + drain wire
M= Galvanized Steel Wire Braid + drain wire
P= Plain Copper Wire Braid
R= Aluminum/Polyester + drain wire
S= Steel Wire Armor
T= Tinned Copper Wire Braid
W=Tinned Copper Wire Braid + Bronze Overbraid Armor
X= Not Applicable
5. CONDUCTOR
D= Tinned Annealed Copper Wire
N= Plain Annealed Copper Wire
6. NUMBER OF CONDUCTORS/PAIRS/TRIADS
7. CORE TYPE
C= Power/Control
P= Pair
T= Triad
Q= Quad
8. CONDUCTORCROSS SECTIONAREA (mm2)
9. JACKET COLOUR
OR= Orange
BK= Black
WH= White
GY= Grey
BR= Brown
RE= Red
BL= Blue
GN= Green
EA= Green/Yellow (Earth)
SHIPBOARD /OFFSHORE CABLE - PRODUCT CODES
21 3 4 5 6 7 8 9
PJ C -PA GN/4 C 2.5 BK
COLOUR CODES
Power 1C 2C 3C 4C 5C STANDARD
PF BK BK-WH BK-WH-RE BK-WH-RE-GN BK-WH-RE-OR-GN US (IEEE 45/1580)
PV WH RE-BK BK-WH-RE BK-WH-RE-EA BK-WH-RE-OR-EA US (IEEE 45/1580)
PJ WH BR-BL BR-BL-EA BR-BK-GY-EA BR-BK-GY-BL-EA EUROPE (UK) w/Earth
PA WH RE-BK RE-BK-EA RE-WH-BL-EA RE-WH-BL-BK-EA AUSTRALIA (Fixed)
PD WH BR-BL BR-BL-EA BR-BL-BK-EA BR-WH-BL-BK-EA AUSTRALIA (Flexible)
Control
CG White with Numbers & Words + Green
CA White with Numbers & Words + Earth
CB White with Numbers & Words No Earth or Green
Instrumentation Pairs Triads
DE WH-BK with Numbers & Words WH-BK-RE with Numbers & Words
“1 ONE-1 ONE”, “2 TWO-2 TWO”, etc “1 ONE-1 ONE-1 ONE”, “2 TWO-2 TWO-2 TWO”, etc
Single Pair and Single Triad Wires are not printed.
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 57
LUGGING RECOMMENDATION
Cut at required length and remove.
Cut section and slide towards the end ofthe conductor* (allow 5mm clearance)
Place standard lug at the end of conductor
Gently push both lug and section until theymeet the jacket. Cut and remove section.
Compress lug using hexagonal die and
hydraulic crimper
*Stripping at 25mm maximum lengths is recommended. For longerlengths cutting and stripping in 25mm sections is advised.
1
2
3
4
5
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 158
INSTALLATION RECOMMENDATION
CORRECTION FACTORS FOR CABLE CURRENT RATING
Bunching of cable
Where more than six cables are bunched together and
operating at their maximum capacity, a correction factor of 0.85
should be applied (assuming insufficient free air circulation).
Single core cables are exempted from this requirement
Ambient temperature
The maximum current ratings in this catalogue are based on an
ambient temperature of 45°C. For other ambient temperatures,
the correction factors shown below should be applied.
* Shorepower cable only
INSTALLATION
Cable runs should be fixed in straight lines as far as
practicable. The minimum bending radius for cable should be
selected in accordance with the table below.
The installation of cables across expansion joints in any
structure should be avoided. Where this is not feasible,
a loop of cable sufficient to accommodate the expansion of
the joint should be provided. The internal radius of the loop is
to be at least 12 times the overall diameter of the cable.
Cables should be installed away from heat sources as far as
practicable. If this cannot be avoided and there is possibility
of damage to the cable, then suitable shields, insulation or
other protective measures should be installed.
Cables are not to be coated or painted with materials
which may adversely affect their jacket or fire performance.
Cables should be installed away from sources of mechanical
damage, as far as is practicable. If this cannot be avoided the
cables should be protected with suitable metallic casing.
VOLTAGE DROP
When selecting cable size, consideration must be given tovoltage drop. Refer to formula and table below:
Vd = L x I mV/Am1000
Where: Vd = voltage drop in volts
L = route length of cable in meters
I = current to be carried in amps
mV/Am = millivolts per ampere metre value
(the drop in voltage shall not exceed 5% of supply voltage)
CONDUCTOR SIZE - SHORT CIRCUIT RATING
The short circuit current ratings in this catalogue are based ona one second duration. To calculate the maximum permissibleshort circuit ratings, the following formula should be applied.
C x 146
t
C = cross section area of conductor in mm2
t = short circuit time in seconds
MAXIMUM INSTALLATION TENSION
To calculate the maximum allowable tension of cables duringinstallation the following formula should be applied:
50 x C x Nc
C = cross section area of conductor in mm2
Nc = total number of cores
Maximum tension must not exceed 20,000N (kg = N/9.81)
* All information above is intended as a guide only
Unbraided all sizes 4X
Unbraided, fire resistant all sizes 8X
Braided all sizes 6X
Braided, fire resistant all sizes 10X
Nylon protected all sizes 15X
Cable Cable MinimumConstruction OD bending radius
(times cable OD)
35°C 40°C 45°C 50°C 55°C 60°C 65°C
90 1.10 1.05 1.00 0.94 0.88 0.82 0.74
110* 1.04 1.00 0.96 0.93 0.89 0.85 0.81
Maximum conductor
temperature
°°CC
Ambient air temperature
0.5 - 65 - -0.75 - 99 - -
1 - 132 - 49.71.5 215 198 30.0 31.92.5 358 330 16.4 17.44 572 528 10.2 10.86 858 792 6.81 7.2310 1430 1320 4.05 4.30
16 2288 2112 2.55 2.7125 3575 3300 1.62 1.7235 25005 4620 1.17 1.2550 7150 6600 0.872 0.92970 10010 9240 0.615 0.65795 13585 12540 0.457 0.491120 17150 15840 0.373 0.403150 21450 19800 0.316 0.344185 26455 24420 0.269 0.296240 34320 31680 0.227 0.252300 42900 39600 0.202 0.227400 57200 52800 0.183 0.208500 75100 66000 0.170 0.195630 90090 83160 0.159 0.184
Cross Short Circuit Voltage DropSectional Current at 50Hz
Area (Amps for (mV/Am)(mm2) 1 second)
90°C 110°C 90°C 110°C
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 59
CONDUCTOR DATA
CONVERSION TABLE - CROSS-SECTIONAL AREA
AWG/MCM TO MM2
AWG mm2
20 0.51918 0.82316 1.3114 2.0812 3.3110 5.268 8.376 13.304 21.152 33.621 42.41
1/0 53.492/0 67.433/0 85.014/0 107.2
MCM mm2
250 126.7300 152.0350 177.3400 202.7450 228.0500 253.4550 278.7600 304.0650 329.4700 354.7750 380.0800 405.4850 430.7900 456.0950 481.4
1000 506.71250 633.41500 760.01750 886.72000 1013.4
CONDUCTOR - CONSTRUCTION
Triangle uses very fine 0.3mm copper wires to ensure maximum
flexibility and ease of use. The following table from IEC 60228
provides a comparative analysis.
size (mm2) Triangle class 2 class 5 class 6
0.5 7 X 0.30 7 X 0.30 16 X 0.20 28 X 0.150.75 12 X 0.30 7 X 0.37 24 X 0.20 42 X 0.15
1 14 X 0.30 7 X 0.43 32 X 0.20 56 X 0.151.5 21 X 0.30 7 X 0.52 30 X 0.25 84 X 0.152.5 35 X 0.30 19 X 0.41 50 X 0.25 140 X 0.154 56 X 0.30 19 X 0.52 56 X 0.30 224 X 0.156 84 X 0.30 19 X 0.64 84 X 0.30 192 X 0.2010 144 X 0.30 49 X 0.51 80 X 0.40 320 X 0.2016 224 X 0.30 49 X 0.65 128 X 0.40 512 X 0.2025 350 X 0.30 84 X 0.62 200 X 0.40 800 X 0.2035 490 X 0.30 133 X 0.58 280 X 0.40 1120 X 0.20
50 707 X 0.30 133 X 0.69 400 X 0.40 705 X 0.3070 980 X 0.30 189 X 0.69 356 X 0.50 999 X 0.3095 1344 X 0.30 259 X 0.69 485 X 0.50 1340 X 0.30120 1672 X 0.30 336 X 0.67 614 X 0.50 1699 X 0.30150 2090 X 0.30 592 X 0.69 765 X 0.50 2123 X 0.40185 2584 X 0.30 494 X 0.69 994 X 0.50 1470 X 0.40240 3344 X 0.30 627 X 0.70 1125 X 0.50 1905 X 0.40300 4144 X 0.30 61 X 2.50 1530 X 0.50 2385 X 0.40400 5488 X 0.30 61 X 2.89 2035 X 0.50 3200 X 0.40500 6944X 0.30 61 X 3.20 1768 X 0.50 4010 X 0.40630 8736 X 0.30 59 X 3.70 3200 X 0.50 5020 X 0.40
CONDUCTOR - DC RESISTANCE
To calculate the DC Resistance of copper conductors for a given
temperature (°C), the resistance at 20°C, as detailed must be
multiplied by the appropriate correction factor below.
AMBIENT CorrectionTemperature Factor(°C)
20 1.00025 1.02030 1.03935 1.05940 1.07945 1.09850 1.11855 1.13860 1.15765 1.17770 1.19675 1.21680 1.23685 1.25590 1.275
OVERALL DIAMETER OF CABLEEXCEEDING NOT EXCEEDING
(mm) (mm)
NON-ARMOUREDCABLES
(mm)
ARMOUREDCABLES
(mm)
- 8 200 2506 13 250 30013 20 300 35020 30 350 40030 - 400 450
normal Maximum resistance ofcross- conductor at 20°CsectionalArea plain copper Tinned Copper(mm2) Ohm/Km Ohm/Km
0.5 39.0 40.10.75 26.0 26.7
1 19.5 20.01.5 13.3 13.72.5 7.98 8.214 4.95 5.096 3.30 3.3910 1.91 1.9516 1.21 1.2425 0.780 0.79535 0.554 0.56550 0.386 0.39370 0.272 0.27795 0.206 0.210120 0.161 0.164150 0.129 0.132185 0.106 0.108240 0.0801 0.0817300 0.0641 0.0654400 0.0486 0.0495500 0.0384 0.0391630 0.0287 0.0292
SECURING OF CABLES
Cables should be effectively supported and secured
using flame retardant clips, saddles or straps. Special
care should be taken to avoid any damage caused by
excessive tensioning during installation.
The distance between fixing points should be
selected according to cable type and probability of
vibration, but should not exceed 450mm.
Where cables are installed below cable trays, ladder
or supports, the fixing distance for securing the cable
should be in accordance with the table below.
CURRENT CARRYING CAPACITIESMUD FLUID IMMERSION TESTS
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 160
MUD Fluid Immersion TestsSpecific grades of our Cable Jackets have been tested by Underwriters Laboratories and meet or exceed theFluid Immersion schedules as listed in NEK-TS-606:2009 – MUD and IEC 600092-350-SHF-2 / MUD Annex G
FIRE PERFORMANCE TESTING - (IEC 60332-3, AS/NZS 1660.5.1) (IEC 60331, AS/NZS 1660.5.5)
(IEC 60754-1&2, AS/NZS 1660.5.3) (IEC 60134-1&2, AS/NZS 1660.5.2)
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 61
TRIANGLE CABLES INTRODUCES RIPCORD TECHNOLOGY
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 162
STEP 1 STEP 2
STEP 3 STEP 4
RECOMMENDED CABLE DRUM HANDLING PROCEDURES
I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 63
T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 164
Triangle Flexible400mm2 Cablebending radius
(actual size)
Bending Radius is the Only truemeasure for cable flexibility.
Triangle manufactures the most flexible cableswith the smallest bending radius!
104mm
Marine Catalogue issue 9.1
Manufacturing FacilitiesMelbourne, AUSTRALIANakorn Ratchasima, THAILANDWorcester, MA USA
Sales/Distribution Offices
AUSTRALIA
AdelaideBrisbaneHobartMelbournePerthSydneyTownsville
MALAYSIA
Kuala Lumpur
NEW ZEALAND
AucklandChristchurchWellington
THAILAND
BangkokNakorn Ratchasima
USA
HoustonSeattleWorcester
Superior Cable Solutions www.tricab.com