Upload
rahulranjan
View
233
Download
2
Embed Size (px)
Citation preview
8/10/2019 Tricab Marine Cables
1/58
Tricab LSZH 110C FlexibleMarine Cables issue 2.8
8/10/2019 Tricab Marine Cables
2/58
FRONT COVER
Top Left
108ft Orca Class Inshore Patrol Vesselby Victoria Shipyard, Victoria BC.
Top Right
Alakai 349ft vehicle-passenger fastcatamaran ferry by Austal USA,Mobile AL. www.austalusa.com
Bottom Left
Aussie Rules 228ft Expedition Yachtby Oceanfast, Australia.
Bottom Right
U.S. Naval LCSby Austal USA,Mobile AL. www.austalusa.com
Top
Happy Days 164ft composite ya
by Delta Marine, Seattle WA.
www.deltamarine.com
Center
Sea Fighter (FSF-1) 262ft US N
experimental SWATH by Nichols
Brothers, Seattle WA.
Left
F/V Franz 1600m3 Fishing Vesse
the Marco Chilena Group, Chile.
8/10/2019 Tricab Marine Cables
3/58
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 1
Introduction
Welcome to issue 2.8 of our Marine Cables catalog.
Tricab has been pioneering and re-defining cable technologies for over 30 years. The cables within this
catalog represent a milestone for the marine industry as they combine the highest technical performance,
outstanding flexibility, reduced weight and user-friendliness.
All cables now include a high strength ripcord under all jackets, For easy and safe stripping of cable. This also
applies to larger sized insulated conductors.
Tricab Marine Cables conform to major international standards including IEC and IEEE and carry approvals
from ABS, LR, DNV, BV, NATO, USCG, TC NAVSEA.
Our cables are used globally across a broad range of platforms, including Navy and Defense Vessels, Fast
Ferries, Commercial and Work Boats, Tankers, Passenger Liners, and Megayachts.
We have now fully established our state of the art manufacturing facility in Massachusetts. This enables us to
provide you with the highest possible service levels, and ensures reliable supply for your project
requirements.
We hope that you find our latest issue of real value, and we look forward to working together in the future.
Right
M/V Fairweather 235ft vehicle-passenger fast catama-
ran ferry by Derecktor Shipyards, Bridgeport CT.
8/10/2019 Tricab Marine Cables
4/582 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
Approvals and Certifications
8/10/2019 Tricab Marine Cables
5/58
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 3
Table of Contents
M R I N E C B L E S
PRODUCT
SERIE
S
Flam
eR
etarda
nt
IEEE
1202
IEC6
0332
-1
Flam
eR
etarda
nt
IEEE
1202
IEC6
0332
-3A
Halog
enFree
MIL
-DTL
-24643B
NEM
AWC57PT
7
IEC6
0754
-1&2
Smok
eEm
ission
NEM
AWC57PT7
IEC6
1034
-1&2
Fire
Resista
nt
IEC6
0331
,IEC
60331-11
IEC6
0331
-21
PAGENUMBER
Features and Benefits 4
Low Smoke Zero Halogen (LSZH) - what does it mean? 8
POWER AND CONTROL 110C
Unarmored BV 12
Braided/Armored DV 14
INSTRUMENTATION 110C
Collective screened
Unarmored RC 16
Braided/Armored RS 18
Individual and collective screened
Unarmored EW 20
Braided/Armored EG 22
POWER AND CONTROL Fire Resistant 110C
Unarmored RR 24
Braided/Armored BH 26
INSTRUMENTATION Fire Resistant 110C
Collective screened
Unarmored ES 28
Braided/Armored FJ 30
Individual and collective screened
Unarmored FC 32
Braided/Armored FL 34
SHOREPOWER 110C EZ 36
SWITCHBOARD WIRE 110C UP 38
VARIABLE FREQUENCY DRIVE 110C
Shielded DF 39
8/10/2019 Tricab Marine Cables
6/584 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
Features and Benefits
Fine Copper Stranding - Tricab uses very finecopper wire for all conductors, in accordancewith ASTM B3-01, ASTM B33-00 and IEC60228.
Round Concentric Cores - Tricab exclusivelymanufactures round cores throughout itsentire size range, and does not use sectorialconductors.
Lightweight - Tricab has developed specific
product ranges that have reduced weight.
Small OD - Tricab has developed specificproduct ranges that have reduced OD's.
Flexible Construction - Tricab uses acombination of fine conductors, specialcompounds and manufacturing processes toproduce a very flexible cable.
Foot marking - All Tricab cables are foot-markedas standard, with a descending number (metremarking also available).
Product marking - Tricab offers personalizedtext messages printed onto the cable at regularintervals, even for short lengths.
F E A T U R E S B E N E F I T S
Provides quick and efficient removal of any length of jacket orinsulation without the risk of damage to underlying components.
Eliminates the risk of injury from using razor knives or blades.
Significantly increased flexibility has numerous practical benefits,including reduced installation time and easier cable handing.
These benefits translate directly into reduced installation time andcost. Fine stranded conductors also offer improved performanceand reliability when subjected to vibration.
Standard lugs, terminals and connectors can be used,saving installation time, inventory and cost - also providing betterelectrical contact with standard round lugs.
Especially relevant to high speed craft, where weight saving
translates into improved performance and overall cost benefits.
Additional cables can be installed within a specified cable tray,ladder or conduit. A smaller bending radius benefits tight configurations,and smaller glands reduce cost.
Reduced installation time and cost, improved bending radius andsafer cable handling (especially larger sizes).
Assists the installation process and enables accurate stockmanagement.
Project Reference Codes, Company Name, Part Numbers, Quality Data,Marketing Information etc. can all be clearly marked.
Ripcord - Tricab includes a high strength ripcordunder all bedding and overall jackets, and under
the insulation on 10mm2 and larger conductors.
8/10/2019 Tricab Marine Cables
7/58
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 5
Make to order facility- Tricab can manufacture cablesexactly to customer specifications.
Global distribution - Tricab operates its own network of
company offices and warehouses worldwide. We currently
have operations in the Pacific, Asia, the Middle East, Europe
and North America.Research & development - Tricab maintains a very active
R&D programme, working very closely with our sales team
and customers. In conjunction with our in-house
laboratory, we are continually improving cable performance.
Quick response - Tricab has invested in manpower,
machinery and materials to provide a short leadtime
manufacturing capability.
Reliable long-term partner - Tricab has been supplying
innovative cable solutions since 1978. We believe in long
term partnerships and have a solid track record of
successfully completed projects worldwide.
Approvals - Tricab maintains approvals from numerous
certification bodies, including LR, DNV, ABS, BV, UL, CSA. If
required, we also obtain specific case approval.
Quality accreditation - Tricab operates an accredited
Quality system in accordance with ISO 9001:2008, both
within our manufacturing plant and our global offices and
warehouses.
No need for the user to compromise or accept analternative cable. Customers receive exactly what theyneed.
We support customer projects wherever they may be,streamlining logistics, increasing supply reliability andsaving time and money.
New cable technologies are introduced to our customers onan ongoing basis.
When cable is needed urgently, either due to an emergencyor unexpected contingency, Tricab has the systems in placeto fast-track the manufacturing process, reducingdowntime and saving time and money.
We believe that satisfied customers are our strength andwe do everything in our power to ensure that we bothgrow and prosper over the long term.
Reliable certification simplifies the task for procurementand engineering, saving time and money. It also allowscables left over from one project to be used for futureprojects.
We continually improve our quality performance, whichin turn provides improved products and services to ourcustomers.
F E A T U R E S B E N E F I T S
8/10/2019 Tricab Marine Cables
8/58
Below
M2 Series Catamaran by Moose
Boats, San Francisco CA.
Above
108ft Orca Class Inshore Patrol
Vessel by Victoria Shipyard, Victo-
ria BC.
Below
Midnightbuilt by Fitzroy Yachts
NewZealand. www.fitzroyyachts.co.
8/10/2019 Tricab Marine Cables
9/58
Below
Alakai 349ft vehicle-passenger
fast catamaran ferry by Austal USA,
Mobile AL. www.austalusa.com
Above
Vanquish 120ft Sportyacht by
Palmer Johnson. Sturgeon Bay WI.
8/10/2019 Tricab Marine Cables
10/588 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
LSZH
LSZH simply translates to Low Smoke Zero Halogen and refers to the behavior of
chemical compounds when combusted - specifically the quantity of smoke generated
and the toxicity of the emissions. Tricab uses only materials generating less than 0.5%
HCL emissions
Halogens - What are they?
Halogens are a group of five elements comprising; Fluorine, Chlorine, Bromine, Iodine
and Astatine.
Halogens - and the effect of combustion
In their basic form, Halogens are very toxic, strong oxidizers and very chemically
reactive. In the event of combustion, LSZH and non LSZH cables behave in very
different ways, as indicated below.
Fluorine Chlorine Bromine Iodine Astatine
Tricab LSZH Cables
NO HALOGENS HALOGENEMISS IONS
CORROSIVEACIDS
LOW SMOKE DENSE SMOKE
NO ACIDS
Non LSZH Cables
Low Smoke Zero Halogen (LSZH)What does it mean?
8/10/2019 Tricab Marine Cables
11/58
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 9
What is the difference between LSZH and non LSZH cables?
LSZH cables have a zero Halogen content, emit no toxic fumes, generate very little smoke and produce no corrosive orcaustic acids. LSZH cables are therefore ideally suited for all marine applications where personnel safety and protectionof valuable equipment are of paramount importance.
Non LSZH cables, or Halogenated Cables, are typically manufacturedfrom thermoplastic compounds, such as PVC. On combustion, thesecompounds generate highly toxic fumes that cause severe irritation tothe eyes, nose, mouth, throat and lungs. Increased concentrations areconsidered fatal to humans.
They also generate large volumes of dense black smoke that blocksvisibility and severely disrupts evacuation procedures. The smoke andfumes can also lead to suffocation from smoke inhalation. A one metrelength of burning cable that contains 0.85Kg of PVC will completelyobscure a room of 1000m3 with black toxic smoke in less than fiveminutes.
When combusted, Halogens combine with moisture to formHydrochloric Acid. This extremely corrosive acid is potentially deadlyto humans and always causes extensive property damage. Acids of thisnature aggressively attack electrical switchboards, motors, fixtures,furnishings, floor coverings, paint surfaces etc. In many cases theeffects of acid corrosion after a fire are much more severe than theactual fire damage itself.
Tricab LSFLEX
- Insulation & Jacket Materials
are halogen free
emit low smoke
do not form corrosive acids
have an extremely low fuel element
Low Smoke Zero Halogen (LSZH)What does it mean?
IEEE 1202
NEMA WC57 Pt7
MIL-DTL-24643B
Tricab LSFLEX - Insulation &Jacket Materials comply withthe following standards:
8/10/2019 Tricab Marine Cables
12/58
Below
Benchijigua Express 416ft high speed
vehicle-passenger trimaran ferry by
Austal, Australia. www.austal.com
8/10/2019 Tricab Marine Cables
13/58
Tricab Cablesflexible lightweightLow Smoke Zero HalogenMarine Cables
8/10/2019 Tricab Marine Cables
14/58
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11Available in plain or tinned
Insulation: LSFLEX
R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant,Low Smoke, Zero Halogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351) Includes ripcord on10mm2 and larger
ssembly:Conductors cabled with filler as
required and overall binder tape orAluminum/ Polyester Shield + drain wire
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic,Flame Retardant, Low Smoke, Zero Halogen(TPO/TPPO to IEEE-1580) (SHF-1 to IEC 60092-359)Splash resistant to oil, skydrol, gasoline, acid,sea water. Resists ozone and UV.
rmor (Optional):All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING600/1000 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNV, BVTransport Canada Marine SafetyCable constructions, Jackets, and Innercomponents to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Power and Control cables suitable for all marine applications.Where mechanical or EMC protection is required see DV series.
Where circuit integrity under fire conditions is required see RR series.
ASTM B3-01ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228IEC 60092-350IEC 60092-353IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
BV
12 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
Flexible IEEE Marine Power & Control
0.6/1kV 110C LSZH
NUMBER OF DIAMETER OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X INSULATION (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 (inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1c 10 1c 6 0.18 0.250 0.270 1.1 54 - 80 69 - 102 102 - 152 58
1c 8 1c 10 0.22 0.295 0.320 1.3 86 - 128 103 - 153 142 - 211 76
1c 6 1c 16 0.27 0.345 0.370 1.5 124 - 185 143 - 214 188 - 280 101
1c 4 1c 25 0.32 0.400 0.435 1.7 184 - 274 207 - 307 258 - 385 133
1c 2 1c 35 0.37 0.455 0.490 2.0 248 - 369 273 - 407 332 - 494 162
1c 1 1c 50 0.44 0.525 0.570 2.3 349 - 519 378 - 563 445 - 662 202
1c 2/0 1c 70 0.51 0.595 0.645 2.6 479 - 713 512 - 762 588 - 875 250
1c 3/0 1c 95 0.61 0.695 0.750 3.0 643 - 957 681 - 1014 769 - 1144 306
1c 236 McM 1c 120 0.66 0.750 0.815 3.3 784 - 1167 825 - 1228 920 - 1368 376
1c 296 McM 1c 150 0.77 0.860 0.930 3.7 988 - 1470 1035 - 1540 1143 - 1700 412
1c 365 McM 1c 185 0.82 0.920 1.000 4.0 1207 - 1796 1257 - 1871 1372 - 2042 464
1c 473 McM 1c 240 0.93 1.025 1.115 4.5 1538 - 2289 1594 - 2372 1722 - 2562 579
1c 592 McM 1c 300 1.03 1.135 1.230 4.9 1894 - 2818 1956 - 2910 2097 - 3121 623
1c 789 McM 1c 400 1.17 1.275 1.385 5.5 2486 - 3699 2555 - 3802 2714 - 4038 785
1c 986 McM 1c 500 1.30 1.420 1.540 6.2 3129 - 4656 3206 - 4770 3382 - 5032 867
1c 1243 McM 1c 630 1.45 1.575 1.705 6.8 3918 - 5830 4003 - 5957 4198 - 6247 990
8/10/2019 Tricab Marine Cables
15/58
series
BV
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 1* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
Flexible IEEE Marine Power & Control
0.6/1kV 110C LSZH
NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
2c 16 2c 1.5 0.305 0.330 1.3 51 - 76 69 - 102 109 - 162 20
2c 14 2c 2.5 0.345 0.375 1.5 70 - 104 90 - 134 135 - 201 312c 12 2c 4 0.390 0.425 1.7 97 - 144 119 - 177 170 - 252 40
2c 10 2c 6 0.435 0.470 1.9 130 - 193 154 - 230 210 - 313 50
2c 8 2c 10 0.525 0.570 2.3 206 - 307 235 - 350 302 - 449 67
2c 6 2c 16 0.615 0.670 2.7 298 - 443 332 - 494 410 - 610 91
2c 4 2c 25 0.735 0.795 3.2 443 - 659 483 - 719 576 - 857 113
2c 2 2c 35 0.840 0.910 3.6 598 - 890 644 - 958 749 - 1115 142
3c 16 3c 1.5 0.325 0.350 1.4 63 - 94 81 - 121 124 - 184 17
3c 14 3c 2.5 0.370 0.400 1.6 89 - 132 110 - 163 158 - 235 28
3c 12 3c 4 0.415 0.450 1.8 125 - 186 148 - 221 202 - 300 33
3c 10 3c 6 0.460 0.500 2.0 170 - 253 196 - 291 255 - 380 43
3c 8 3c 10 0.560 0.605 2.4 273 - 406 304 - 452 375 - 558 54
3c 6 3c 16 0.660 0.715 2.9 398 - 592 434 - 646 517 - 770 74
3c 4 3c 25 0.785 0.850 3.4 596 - 887 639 - 951 738 - 1098 93
3c 2 3c 35 0.900 0.975 3.9 808 - 1202 857 - 1275 970 - 1443 115
3c 1 3c 50 1.050 1.135 4.5 1141 - 1698 1198 - 1783 1329 - 1978 144
3c 2/0 3c 70 1.205 1.305 5.2 1569 - 2335 1634 - 2432 1784 - 2655 179
3c 3/0 3c 95 1.415 1.530 6.1 2123 - 3159 2199 - 3273 2375 - 3534 221
3c 236 McM 3c 120 1.535 1.665 6.7 2585 - 3846 2668 - 3970 2858 - 4253 255
3c 296 McM 3c 150 1.770 1.915 7.7 3284 - 4887 3379 - 5028 3598 - 5354 290
3c 365 McM 3c 185 1.905 2.060 8.2 3998 - 5949 4100 - 6101 4335 - 6451 330
3c 473 McM 3c 240 2.130 2.310 9.2 5097 - 7584 5212 - 7755 5474 - 8146 401
3c 592 McM 3c 300 2.370 2.565 10.3 6290 - 9360 6417 - 9549 6709 - 9983 440
4c 16 4c 1.5 0.355 0.385 1.5 79 - 118 99 - 147 145 - 216 17
4c 14 4c 2.5 0.405 0.435 1.7 112 - 167 135 - 200 187 - 278 28
4c 12 4c 4 0.455 0.495 2.0 159 - 237 185 - 275 243 - 362 33
4c 10 4c 6 0.510 0.550 2.2 216 - 321 244 - 364 309 - 460 43
4c8 4c 10 0.615 0.665 2.7 350 - 521 384 - 571 462 - 688 54
4c 6 4c 16 0.725 0.790 3.2 512 - 762 552 - 821 644 - 958 74
4c 4 4c 25 0.870 0.940 3.8 769 - 1144 816 - 1215 925 - 1377 93
4c 2 4c 35 0.995 1.080 4.3 1046 - 1556 1100 - 1637 1224 - 1822 115
4c 1 4c 50 1.165 1.260 5.0 1480 - 2202 1543 - 2296 1688 - 2512 144
4c 2/0 4c 70 1.340 1.450 5.8 2039 - 3034 2111 - 3142 2278 - 3389 179
4c 3/0 4c 95 1.570 1.700 6.8 2759 - 4105 2844 - 4232 3038 - 4521 221
4c 236 McM 4c 120 1.705 1.850 7.4 3363 - 5004 3455 - 5141 3666 - 5455 255
4c 296 McM 4c 150 1.965 2.130 8.5 4270 - 6354 4376 - 6511 4619 - 6873 290
4c 365 McM 4c 185 2.115 2.295 9.2 5206 - 7747 5320 - 7916 5581 - 8304 330
5c 16 5c 1.5 0.390 0.420 1.7 95 - 141 117 - 174 167 - 249 14
5c 14 5c 2.5 0.445 0.480 1.9 136 - 202 161 - 239 218 - 325 22
5c 12 5c 4 0.505 0.545 2.2 194 - 289 222 - 330 286 - 426 26
5c 10 5c 6 0.565 0.610 2.4 266 - 396 297 - 442 369 - 549 34
5c 8 5c 10 0.685 0.740 3.0 431 - 641 469 - 697 555 - 826 43
5c 6 5c 16 0.810 0.875 3.5 632 - 940 676 - 1006 778 - 1157 59
5c 4 5c 25 0.970 1.050 4.2 951 - 1415 1004 - 1494 1125 - 1674 74
5c 2 5c 35 1.110 1.205 4.8 1294 - 1925 1354 - 2015 1493 - 2221 92
5c 1 5c 50 1.300 1.410 5.6 1832 - 2726 1902 - 2831 2064 - 3071 115
7c 16 7c 1.5 0.430 0.465 1.9 117 - 174 141 - 210 197 - 293 1212c 16 12c 1.5 0.570 0.615 2.5 200 - 298 231 - 344 304 - 452 9
19c 16 19c 1.5 0.670 0.725 2.9 293 - 436 330 - 491 414 - 617 9
24c 16 24c 1.5 0.790 0.855 3.4 392 - 583 435 - 648 534 - 795 8
27c 16 27c 1.5 0.805 0.875 3.5 420 - 625 464 - 691 565 - 841 8
33c 16 33c 1.5 0.870 0.945 3.8 500 - 744 548 - 815 657 - 977 7
37c 16 37c 1.5 0.905 0.985 3.9 551 - 820 601 - 894 714 - 1062 7
7c 14 7c 2.5 0.495 0.535 2.1 170 - 253 197 - 294 261 - 388 20
12c 14 12c 2.5 0.655 0.710 2.8 291 - 433 327 - 487 410 - 610 14
19c 14 19c 2.5 0.770 0.835 3.3 431 - 641 473 - 704 570 - 849 14
24c 14 24c 2.5 0.910 0.985 3.9 575 - 856 625 - 930 739 - 1099 13
27c 14 27c 2.5 0.930 1.010 4.0 620 - 923 671 - 998 787 - 1172 13
33c 14 33c 2.5 1.010 1.095 4.4 740 - 1101 795 - 1183 921 - 1370 11
37c 14 37c 2.5 1.050 1.140 4.6 817 - 1216 874 - 1301 1005 - 1496 11
8/10/2019 Tricab Marine Cables
16/58
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11Available in plain or tinned
Insulation: LSFLEX
R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant,Low Smoke, Zero Halogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351) Includes ripcord on10mm2 and larger
ssembly:Conductors cabled with filler asrequired and overall binder tape
Bedding Tape:
Polypropylene
Braid/ rmor Options:
Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%)(also available with drain wire under braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Flame Retardant, LowSmoke, Zero Halogen(TPO/TPPO to IEEE-1580) (SHF-1 to IEC 60092-359)Splash resistant to oil, skydrol, gasoline, acid,sea water. Resists ozone and UV.
rmor (Optional):
All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING600/1000 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNV, BVTransport Canada Marine SafetyCable constructions, Jackets, and Innercomponents to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Power and Control cables suitable for all marine applications where mechanical or EMC protectionis required. Where circuit integrity under fire conditions is required see BH series.
ASTM B3-01ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228IEC 60092-350
IEC 60092-353IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
DV
14 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NOMINAL NOMIINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1c 10 1c 6 0.19 0.24 0.320 0.350 2.1 87 - 129 105 - 157 147 - 219 58
1c 8 1c 10 0.24 0.28 0.365 0.395 2.4 125 - 186 146 - 217 193 - 288 76
1c 6 1c 16 0.28 0.33 0.415 0.445 2.7 169 - 251 192 - 286 245 - 365 101
1c 4 1c 25 0.34 0.38 0.470 0.510 3.1 237 - 353 263 - 392 324 - 482 133
1c 2 1c 35 0.39 0.43 0.525 0.570 3.4 309 - 460 338 - 503 405 - 603 162
1c 1 1c 50 0.46 0.50 0.595 0.645 3.9 419 - 623 452 - 672 527 - 785 202
1c 2/0 1c 70 0.53 0.57 0.665 0.725 4.4 559 - 832 596 - 886 680 - 1012 250
1c 3/0 1c 95 0.62 0.67 0.765 0.830 5.0 737 - 1097 779 - 1159 875 - 1302 306
1c 236 McM 1c 120 0.67 0.72 0.820 0.890 5.3 885 - 1317 930 - 1384 1033 - 1537 376
1c 296 McM 1c 150 0.78 0.83 0.930 1.005 6.0 1104 - 1643 1155 - 1718 1271 - 1891 412
1c 365 McM 1c 185 0.84 0.88 0.990 1.075 6.5 1331 - 1981 1385 - 2061 1509 - 2245 464
1c 473 McM 1c 240 0.94 0.99 1.095 1.190 7.1 1677 - 2495 1737 - 2584 1873 - 2788 579
1c 592 McM 1c 300 1.05 1.09 1.205 1.310 7.9 2048 - 3047 2113 - 3145 2264 - 3368 623
1c 789 McM 1c 400 1.18 1.23 1.345 1.460 8.8 2659 - 3957 2732 - 4065 2899 - 4314 785
1c 986 McM 1c 500 1.32 1.36 1.490 1.615 9.7 3322 - 4943 3402 - 5063 3587 - 5338 867
1c 1243 McM 1c 630 1.47 1.51 1.645 1.785 10.7 4131 - 6147 4220 - 6279 4423 - 6582 990
Flexible IEEE MarineBraided/Armored Power & Control0.6/1kV 110C LSZH
8/10/2019 Tricab Marine Cables
17/58
series
DV
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 1* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
Flexible IEEE MarineBraided/Armored Power & Control0.6/1kV 110C LSZH
NUMBER OF NOMINAL NOMIINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
2c 16 2c 1.5 0.24 0.29 0.375 0.405 2.4 84 - 125 105 - 157 154 - 229 20
2c 14 2c 2.5 0.28 0.33 0.415 0.450 2.7 108 - 161 131 - 196 185 - 276 312c 12 2c 4 0.33 0.37 0.460 0.500 3.0 139 - 207 165 - 245 224 - 333 40
2c 10 2c 6 0.37 0.41 0.505 0.545 3.3 175 - 260 203 - 302 268 - 398 50
2c 8 2c 10 0.46 0.50 0.595 0.645 3.9 257 - 382 290 - 431 365 - 544 67
2c 6 2c 16 0.55 0.59 0.685 0.745 4.5 355 - 528 393 - 585 480 - 714 91
2c 4 2c 25 0.66 0.70 0.805 0.870 5.2 505 - 751 549 - 817 650 - 967 113
2c 2 2c 35 0.76 0.81 0.910 0.985 5.9 664 - 988 714 - 1062 828 - 1231 142
3c 16 3c 1.5 0.26 0.31 0.395 0.425 2.6 101 - 150 123 - 183 174 - 259 17
3c 14 3c 2.5 0.30 0.35 0.440 0.475 2.9 131 - 195 156 - 232 212 - 315 28
3c 12 3c 4 0.35 0.39 0.485 0.525 3.2 172 - 256 199 - 296 261 - 389 33
3c 10 3c 6 0.39 0.44 0.530 0.575 3.5 220 - 327 250 - 371 317 - 472 43
3c 8 3c 10 0.49 0.53 0.630 0.680 4.1 331 - 493 366 - 544 445 - 663 54
3c 6 3c 16 0.58 0.63 0.730 0.790 4.7 463 - 689 503 - 748 595 - 885 74
3c 4 3c 25 0.71 0.75 0.855 0.925 5.6 667 - 992 714 - 1062 821 - 1222 93
3c 2 3c 35 0.81 0.86 0.970 1.050 6.3 884 - 1315 937 - 1394 1058 - 1574 115
3c 1 3c 50 0.96 1.01 1.120 1.215 7.3 1221 - 1817 1282 - 1907 1421 - 2115 1443c 2/0 3c 70 1.11 1.16 1.275 1.380 8.3 1650 - 2455 1719 - 2558 1878 - 2794 179
3c 3/0 3c 95 1.32 1.36 1.485 1.610 9.7 2200 - 3274 2280 - 3393 2464 - 3666 221
3c 236 McM 3c 120 1.43 1.48 1.605 1.740 10.4 2658 - 3955 2745 - 4084 2943 - 4380 255
3c 296 McM 3c 150 1.66 1.71 1.840 1.990 11.9 3343 - 4974 3442 - 5122 3669 - 5460 290
3c 365 McM 3c 185 1.78 1.83 1.975 2.135 12.8 4047 - 6022 4153 - 6180 4397 - 6542 330
3c 473 McM 3c 240 2.00 2.05 2.200 2.385 14.3 5124 - 7625 5242 - 7801 5514 - 8204 401
3c 592 McM 3c 300 2.23 2.28 2.440 2.640 15.8 6286 - 9354 6417 - 9548 6717 - 9995 440
4c 16 4c 1.5 0.29 0.33 0.425 0.460 2.8 120 - 179 144 - 214 198 - 295 17
4c 14 4c 2.5 0.34 0.38 0.475 0.515 3.1 159 - 237 185 - 276 246 - 366 28
4c 12 4c 4 0.39 0.43 0.525 0.570 3.4 210 - 312 239 - 356 306 - 456 33
4c 10 4c 6 0.44 0.48 0.580 0.625 3.8 273 - 406 305 - 454 378 - 563 43
4c8 4c 10 0.54 0.59 0.685 0.745 4.5 416 - 619 454 - 675 540 - 804 54
4c 6 4c 16 0.65 0.70 0.795 0.865 5.2 585 - 870 629 - 935 729 - 1084 74
4c 4 4c 25 0.79 0.83 0.940 1.015 6.1 851 - 1266 902 - 1342 1020 - 1517 93
4c 2 4c 35 0.91 0.95 1.065 1.155 6.9 1133 - 1686 1191 - 1772 1324 - 1970 115
4c 1 4c 50 1.07 1.12 1.235 1.335 8.0 1571 - 2338 1638 - 2437 1791 - 2666 144
4c 2/0 4c 70 1.24 1.29 1.410 1.525 9.2 2131 - 3171 2207 - 3284 2382 - 3544 179
4c 3/0 4c 95 1.47 1.51 1.640 1.775 10.7 2848 - 4238 2937 - 4370 3140 - 4672 221
4c 236 McM 4c 120 1.59 1.64 1.775 1.925 11.6 3448 - 5131 3544 - 5273 3763 - 5600 255
4c 296 McM 4c 150 1.85 1.90 2.035 2.205 13.2 4340 - 6458 4450 - 6621 4701 - 6995 290
4c 365 McM 4c 185 1.99 2.04 2.185 2.370 14.2 5265 - 7834 5383 - 8009 5652 - 8410 330
5c 16 5c 1.5 0.32 0.37 0.460 0.500 3.0 142 - 211 168 - 250 227 - 337 14
5c 14 5c 2.5 0.38 0.42 0.515 0.560 3.4 189 - 281 218 - 324 283 - 422 22
5c 12 5c 4 0.43 0.48 0.575 0.620 3.7 252 - 375 284 - 422 357 - 531 26
5c 10 5c 6 0.49 0.54 0.635 0.685 4.1 330 - 491 365 - 543 445 - 662 34
5c 8 5c 10 0.61 0.66 0.755 0.815 4.9 506 - 753 547 - 815 642 - 956 43
5c 6 5c 16 0.73 0.78 0.880 0.950 5.7 717 - 1067 765 - 1138 875 - 1302 59
5c 4 5c 25 0.88 0.93 1.040 1.125 6.8 1046 - 1556 1102 - 1640 1232 - 1833 74
5c 2 5c 35 1.02 1.07 1.180 1.280 7.7 1397 - 2079 1461 - 2174 1608 - 2393 92
5c 1 5c 50 1.20 1.25 1.370 1.485 8.9 1943 - 2891 2017 - 3002 2187 - 3255 115
7c 16 7c 1.5 0.36 0.40 0.495 0.535 3.2 173 - 257 201 - 298 264 - 393 12
12c 16 12c 1.5 0.49 0.53 0.630 0.685 4.1 272 - 405 307 - 457 387 - 576 9
19c 16 19c 1.5 0.59 0.63 0.735 0.795 4.8 381 - 567 421 - 627 514 - 764 9
24c 16 24c 1.5 0.70 0.75 0.850 0.925 5.6 496 - 738 543 - 807 649 - 966 8
27c 16 27c 1.5 0.72 0.76 0.870 0.940 5.6 525 - 781 573 - 852 682 - 1014 8
33c 16 33c 1.5 0.78 0.82 0.935 1.015 6.1 614 - 914 665 - 990 782 - 1164 7
37c 16 37c 1.5 0.81 0.86 0.970 1.050 6.3 671 - 998 724 - 1077 845 - 1258 7
7c 14 7c 2.5 0.42 0.46 0.555 0.605 3.6 233 - 347 264 - 393 335 - 498 20
12c 14 12c 2.5 0.57 0.62 0.715 0.775 4.7 374 - 557 413 - 615 504 - 750 14
19c 14 19c 2.5 0.69 0.73 0.835 0.905 5.4 533 - 793 579 - 861 684 - 1017 14
24c 14 24c 2.5 0.82 0.87 0.975 1.055 6.3 697 - 1037 750 - 1116 872 - 1298 13
27c 14 27c 2.5 0.84 0.89 0.995 1.080 6.5 741 - 1103 795 - 1183 920 - 1368 13
33c 14 33c 2.5 0.91 0.96 1.075 1.160 7.0 873 - 1299 931 - 1386 1065 - 1585 11
37c 14 37c 2.5 0.95 1.00 1.115 1.210 7.3 957 - 1424 1018 - 1514 1156 - 1721 11
8/10/2019 Tricab Marine Cables
18/58
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11
Insulation: LSFLEX
R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant,Low Smoke, Zero Halogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351)Splash resistant to oil, skydrol, gasoline, acid,sea water. Resists ozone and UV.
ssembly:Components cabled with filler asrequired and overall binder tape
Screen: Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Binder Tape: Polyester
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke,Zero Halogen (TPO/TPPO to IEEE-1580)(SHF-1 to IEC 60092-359)Splash resistant to oil, skydrol, gasoline, acid,sea water. Resists ozone and UV
rmor (Optional):All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING300 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNVTransport Canada Marine SafetyCable constructions, Jackets, and Innercomponents to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Instrumentation cables suitable for all marine applications.Where mechanical or EMC protection is required see RS series.Where circuit integrity under fire conditions is required see ES series.
ASTM B3-01
ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228
IEC 60092-350IEC 60092-376IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
RC
16 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
10p 18 10p .75 0.715 0.775 3.1 226 - 336 265 - 395 356 - 529 5
12p 18 12p .75 0.740 0.800 3.2 250 - 372 291 - 432 384 - 571 4
1p 18 1p .75 0.270 0.290 1.2 38 - 57 54 - 80 89 - 133 13
2p 18 (quad) 2p .75 0.305 0.335 1.3 54 - 80 72 - 107 112 - 167 8
4p 18 4p .75 0.465 0.500 2.0 100 - 149 126 - 187 185 - 276 7
8p 18 8p .75 0.605 0.660 2.6 175 - 260 209 - 310 286 - 425 5
16p 18 16p .75 0.825 0.895 3.6 321 - 478 366 - 545 470 - 699 4
20p 18 20p .75 0.925 1.000 4.0 394 - 586 444 - 661 560 - 833 4
24p 18 24p .75 1.035 1.120 4.5 479 - 713 535 - 796 664 - 988 3
27p 18 27p .75 1.055 1.145 4.6 521 - 775 578 - 861 710 - 1057 3
36p 18 36p .75 1.190 1.290 5.2 677 - 1007 742 - 1103 890 - 1324 3
Flexible IEEE Marine Collective ScreenedInstrumentation300V 110C LSZH
8/10/2019 Tricab Marine Cables
19/58
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
series
RC
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 17
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* TRIADS (t) TRIADS (t) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1p 14 1p 2.5 0.360 0.390 1.6 72 - 107 92 - 137 139 - 207 30
2p 14 (quad) 2p 2.5 0.420 0.455 1.8 124 - 185 148 - 220 202 - 300 20
4p 14 4p 2.5 0.655 0.705 2.8 230 - 342 266 - 396 349 - 519 17
8p 14 8p 2.5 0.870 0.940 3.8 422 - 628 469 - 699 578 - 861 12
10p 14 10p 2.5 1.035 1.120 4.5 547 - 814 603 - 898 732 - 1089 12
16p 14 16p 2.5 1.200 1.300 5.2 802 - 1193 867 - 1290 1016 - 1512 10
20p 14 20p 2.5 1.345 1.455 5.8 993 - 1478 1066 - 1586 1232 - 1834 10
24p 14 24p 2.5 1.505 1.630 6.5 1209 - 1799 1290 - 1920 1477 - 2198 8
27p 14 27p 2.5 1.540 1.670 6.7 1325 - 1972 1408 - 2096 1599 - 2380 8
36p 14 36p 2.5 1.745 1.890 7.6 1741 - 2591 1835 - 2730 2051 - 3051 7
12p 14 12p 2.5 1.070 1.155 4.6 616 - 917 674 - 1003 807 - 1201 11
1t 18 1t .75 0.285 0.305 1.2 44 - 65 60 - 90 98 - 145 11
3t 18 3t .75 0.485 0.525 2.1 113 - 168 140 - 208 202 - 300 7
4t 18 4t .75 0.530 0.575 2.3 137 - 204 166 - 248 234 - 348 5
7t 18 7t .75 0.640 0.695 2.8 214 - 318 249 - 371 331 - 492 4
1t 16 1t 1.5 0.340 0.365 1.5 69 - 103 88 - 131 132 - 197 17
3t 16 3t 1.5 0.595 0.645 2.6 186 - 277 219 - 326 294 - 438 11
4t 16 4t 1.5 0.655 0.710 2.8 228 - 339 264 - 393 347 - 516 8
7t 16 7t 1.5 0.800 0.865 3.5 364 - 542 408 - 607 508 - 756 7
1t 14 1t 2.5 0.380 0.415 1.7 94 - 140 116 - 172 165 - 246 25
3t 14 3t 2.5 0.685 0.740 3.0 262 - 390 300 - 446 386 - 574 17
4t 14 4t 2.5 0.755 0.815 3.3 325 - 484 366 - 545 461 - 686 12
7t 14 7t 2.5 0.920 1.000 4.0 527 - 784 577 - 859 692 - 1030 11
Flexible IEEE Marine Collective ScreenedInstrumentation300V 110C LSZH
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1p 16 1p 1.5 0.320 0.345 1.4 54 - 80 72 - 107 114 - 170 202p 16 (quad) 2p 1.5 0.370 0.400 1.6 90 - 134 111 - 165 159 - 236 13
4p 16 4p 1.5 0.570 0.615 2.5 163 - 243 195 - 289 267 - 397 11
8p 16 8p 1.5 0.755 0.815 3.3 294 - 437 335 - 499 430 - 640 8
10p 16 10p 1.5 0.895 0.965 3.9 381 - 567 430 - 639 542 - 806 8
12p 16 12p 1.5 0.925 1.000 4.0 426 - 634 476 - 709 592 - 881 7
16p 16 16p 1.5 1.035 1.120 4.5 551 - 820 607 - 904 736 - 1096 6
20p 16 20p 1.5 1.160 1.255 5.0 680 - 1012 743 - 1105 887 - 1320 6
24p 16 24p 1.5 1.295 1.405 5.6 828 - 1232 898 - 1337 1059 - 1576 5
27p 16 27p 1.5 1.330 1.440 5.8 904 - 1345 976 - 1452 1141 - 1697 5
36p 16 36p 1.5 1.500 1.625 6.5 1183 - 1760 1264 - 1881 1450 - 2157 4
8/10/2019 Tricab Marine Cables
20/58
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11
Insulation: LSFLEX
R-30, Cross-linked, Polyolefinic,Thermoset, Flame Retardant, Low Smoke, ZeroHalogen (LSX to IEEE-1580) (HF-90 to IEC 60092-351)Splash resistant to oil, skydrol, gasoline, acid, seawater. Resists ozone and UV.
ssembly:Components cabled with filler asrequired and overall binder tape
Screen:
Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Binder Tape: Polypropylene
Braid/ rmor Options:
Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke, Zero Halogen (TPO/TPPO toIEEE-1580) (SHF-1 to IEC 60092-359) Splashresistant to oil, skydrol, gasoline, acid, sea water.
Resists ozone and UV.
rmor (Optional):All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING300 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNVTransport Canada Marine SafetyCable constructions, Jackets, and Inner
components to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Instrumentation cables suitable for all marine applications,where mechanical or EMC protectionis required. Where circuit integrity under fire conditions is required see FJ series.
ASTM B3-01ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228IEC 60092-350IEC 60092-376IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
RS
18 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)- (kg/km) (lbs/kft)- (kg/km) (lbs/kft)-(kg/km) (Amps)
1p 18 1p .75 0.20 0.25 0.330 0.360 2.2 73 - 109 92 - 137 135 - 201 13
2p 18 (quad) 2p .75 0.24 0.29 0.370 0.400 2.4 93 - 138 114 - 170 162 - 241 8
4p 18 4p .75 0.39 0.44 0.525 0.570 3.4 161 - 240 190 - 283 258 - 383 7
8p 18 8p .75 0.53 0.58 0.670 0.725 4.4 255 - 379 292 - 434 377 - 561 510p 18 10p .75 0.64 0.68 0.780 0.845 5.1 321 - 478 364 - 541 462 - 687 5
12p 18 12p .75 0.66 0.70 0.805 0.870 5.2 349 - 519 393 - 585 494 - 735 4
16p 18 16p .75 0.74 0.79 0.890 0.965 5.8 431 - 641 480 - 714 591 - 880 4
20p 18 20p .75 0.84 0.88 0.985 1.070 6.4 517 - 769 571 - 849 694 - 1033 4
24p 18 24p .75 0.94 0.99 1.095 1.190 7.1 617 - 918 677 - 1007 813 - 1210 3
27p 18 27p .75 0.96 1.01 1.120 1.215 7.3 662 - 985 723 - 1076 862 - 1283 3
36p 18 36p .75 1.10 1.14 1.255 1.360 8.2 837 - 1245 905 - 1347 1061 - 1579 3
Flexible IEEE Marine Collective ScreenedBraided/Armored Instrumentation300V 110C LSZH
8/10/2019 Tricab Marine Cables
21/58
series
RS
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 19
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)- (kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* TRIADS (t) TRIADS (t) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1p 14 1p 2.5 0.29 0.34 0.425 0.460 2.8 118 - 176 142 - 211 196 - 292 30
2p 14 (quad) 2p 2.5 0.35 0.39 0.480 0.525 3.2 180 - 268 207 - 308 269 - 400 20
4p 14 4p 2.5 0.57 0.62 0.715 0.775 4.7 316 - 470 355 - 529 446 - 663 17
8p 14 8p 2.5 0.78 0.82 0.935 1.010 6.1 537 - 799 588 - 875 705 - 1048 12
10p 14 10p 2.5 0.94 0.98 1.095 1.190 7.1 684 - 1018 744 - 1106 880 - 1310 12
12p 14 12p 2.5 0.97 1.02 1.130 1.225 7.4 759 - 1129 820 - 1221 961 - 1431 11
16p 14 16p 2.5 1.09 1.14 1.260 1.370 8.2 961 - 1430 1029 - 1532 1186 - 1765 10
20p 14 20p 2.5 1.23 1.28 1.405 1.525 9.2 1172 - 1744 1248 - 1857 1423 - 2117 10
24p 14 24p 2.5 1.39 1.44 1.570 1.700 10.2 1411 - 2100 1496 - 2226 1690 - 2515 8
27p 14 27p 2.5 1.42 1.47 1.605 1.740 10.4 1532 - 2280 1619 - 2409 1817 - 2704 8
36p 14 36p 2.5 1.62 1.66 1.810 1.960 11.8 1975 - 2939 2072 - 3084 2296 - 3416 7
1t 18 1t .75 0.22 0.26 0.345 0.375 2.3 80 - 119 100 - 148 145 - 216 11
3t 18 3t .75 0.41 0.46 0.550 0.595 3.6 178 - 265 208 - 310 278 - 414 7
4t 18 4t .75 0.46 0.50 0.595 0.645 3.9 207 - 308 240 - 357 315 - 469 5
7t 18 7t .75 0.56 0.61 0.705 0.765 4.6 299 - 445 338 - 503 427 - 635 4
1t 16 1t 1.5 0.27 0.32 0.400 0.435 2.6 112 - 167 135 - 200 187 - 278 17
3t 16 3t 1.5 0.51 0.56 0.660 0.715 4.3 265 - 394 301 - 448 385 - 572 11
4t 16 4t 1.5 0.57 0.62 0.720 0.780 4.7 314 - 467 353 - 526 444 - 661 8
7t 16 7t 1.5 0.71 0.75 0.860 0.935 5.6 469 - 698 516 - 768 624 - 929 7
1t 14 1t 2.5 0.31 0.36 0.445 0.485 2.9 143 - 213 168 - 250 225 - 335 25
3t 14 3t 2.5 0.60 0.65 0.750 0.810 4.9 354 - 527 395 - 588 489 - 728 17
4t 14 4t 2.5 0.67 0.71 0.815 0.885 5.3 424 - 631 469 - 697 571 - 850 12
7t 14 7t 2.5 0.83 0.87 0.985 1.065 6.4 649 - 966 703 - 1046 826 - 1229 11
Flexible IEEE Marine Collective ScreenedBraided/Armored Instrumentation300V 110C LSZH
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)- (kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1p 16 1p 1.5 0.25 0.30 0.385 0.415 2.5 95 - 141 117 - 174 166 - 247 20
2p 16 (quad) 2p 1.5 0.30 0.34 0.435 0.470 2.8 139 - 207 163 - 243 219 - 326 13
4p 16 4p 1.5 0.49 0.54 0.635 0.685 4.1 238 - 354 273 - 406 353 - 525 11
8p 16 8p 1.5 0.67 0.71 0.815 0.885 5.3 393 - 585 438 - 651 540 - 804 8
10p 16 10p 1.5 0.80 0.85 0.955 1.035 6.2 499 - 743 551 - 820 671 - 998 8
12p 16 12p 1.5 0.83 0.87 0.985 1.070 6.4 548 - 815 602 - 895 725 - 1079 7
16p 16 16p 1.5 0.93 0.98 1.100 1.190 7.1 688 - 1024 748 - 1113 884 - 1316 6
20p 16 20p 1.5 1.05 1.10 1.220 1.325 8.0 834 - 1241 900 - 1340 1052 - 1566 6
24p 16 24p 1.5 1.19 1.23 1.360 1.475 8.9 1000 - 1488 1074 - 1598 1243 - 1849 5
27p 16 27p 1.5 1.22 1.26 1.390 1.505 9.0 1081 - 1609 1156 - 1721 1329 - 1977 5
36p 16 36p 1.5 1.38 1.43 1.565 1.695 10.2 1383 - 2058 1467 - 2183 1661 - 2471 4
8/10/2019 Tricab Marine Cables
22/58
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11
Insulation: LSFLEX
R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant,Low Smoke, Zero Halogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351) Splash resistant to oil,skydrol, gasoline, acid, sea water. Resists ozone andUV.
Screen: Individual and Collective
Drain Wire: Tinned annealed copper
ssembly: Components cabled with filler asrequired and overall binder tape
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke, Zero Halogen (TPO/TPPO toIEEE-1580) (SHF-1 to IEC 60092-359) Splashresistant to oil, skydrol, gasoline, acid, sea water.Resists ozone and UV.
rmor (Optional):All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.
Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING300 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNVTransport Canada Marine SafetyCable constructions, Jackets, and Innercomponents to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Instrumentation cables suitable for all marine applications.Where mechanical or EMC protection is required see EG series.
Where circuit integrity under fire conditions is required see FC series.
ASTM B3-01
ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228
IEC 60092-350IEC 60092-376IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
EW
20 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
1p 18 1p .75 0.270 0.290 1.2 38 - 57 54 - 80 89 - 133 13
2p 18 2p .75 0.420 0.455 1.8 76 - 113 100 - 148 154 - 228 8
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
4p 18 4p .75 0.510 0.555 2.2 127 - 189 156 - 231 221 - 329 7
8p 18 8p .75 0.640 0.690 2.8 221 - 329 256 - 381 337 - 501 5
10p 18 10p .75 0.755 0.815 3.3 285 - 424 326 - 486 421 - 627 512p 18 12p .75 0.780 0.845 3.4 319 - 475 362 - 538 460 - 684 4
16p 18 16p .75 0.870 0.945 3.8 412 - 613 460 - 684 569 - 846 4
20p 18 20p .75 0.975 1.055 4.2 508 - 756 561 - 835 683 - 1016 4
24p 18 24p .75 1.090 1.180 4.7 616 - 917 675 - 1005 811 - 1207 3
27p 18 27p .75 1.115 1.205 4.8 673 - 1001 734 - 1091 872 - 1298 3
36p 18 36p .75 1.255 1.360 5.4 880 - 1309 948 - 1411 1104 - 1643 3
Flexible IEEE MarineIndividual & Collective Screened Instrumentation300V 110C LSZH
8/10/2019 Tricab Marine Cables
23/58
series
EW
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 2
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* TRIADS (t) TRIADS (t) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
4t 14 4t 2.5 0.775 0.840 3.4 361 - 537 404 - 600 501 - 746 12
7t 14 7t 2.5 0.950 1.030 4.1 588 - 875 640 - 952 758 - 1129 11
1t 14 1t 2.5 0.380 0.415 1.7 94 - 140 116 - 172 165 - 246 25
3t 14 3t 2.5 0.705 0.765 3.1 290 - 432 329 - 489 417 - 621 17
3t 16 3t 1.5 0.615 0.665 2.7 212 - 315 246 - 366 324 - 482 11
4t 16 4t 1.5 0.675 0.735 2.9 261 - 388 298 - 444 384 - 571 8
7t 16 7t 1.5 0.825 0.895 3.6 421 - 626 466 - 694 570 - 848 7
7t 18 7t .75 0.670 0.725 2.9 257 - 382 294 - 437 379 - 563 4
1t 16 1t 1.5 0.340 0.365 1.5 69 - 103 88 - 131 132 - 197 17
1t 18 1t .75 0.285 0.305 1.2 44 - 65 60 - 90 98 - 145 11
3t 18 3t .75 0.505 0.545 2.2 133 - 198 161 - 240 225 - 335 7
4t 18 4t .75 0.555 0.600 2.4 162 - 241 193 - 287 263 - 391 5
12p 14 12p 2.5 1.105 1.200 4.8 715 - 1064 775 - 1153 913 - 1359 11
8p 14 8p 2.5 0.900 0.975 3.9 488 - 726 537 - 799 650 - 967 12
10p 14 10p 2.5 1.070 1.160 4.6 631 - 939 689 - 1025 823 - 1224 12
16p 14 16p 2.5 1.245 1.345 5.4 932 - 1387 999 - 1487 1154 - 1717 10
20p 14 20p 2.5 1.395 1.510 6.0 1156 - 1720 1231 - 1832 1404 - 2089 10
24p 14 24p 2.5 1.565 1.695 6.8 1407 - 2094 1491 - 2219 1685 - 2507 8
27p 14 27p 2.5 1.600 1.735 6.9 1545 - 2299 1631 - 2427 1829 - 2722 8
36p 14 36p 2.5 1.810 1.960 7.8 2033 - 3025 2131 - 3170 2354 - 3503 7
1p 14 1p 2.5 0.360 0.390 1.6 72 - 107 92 - 137 139 - 207 30
2p 14 2p 2.5 0.575 0.625 2.5 167 - 248 199 - 296 272 - 405 20
4p 14 4p 2.5 0.715 0.775 3.1 269 - 400 308 - 459 398 - 593 17
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
Flexible IEEE MarineIndividual & Collective Screened Instrumentation300V 110C LSZH
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1p 16 1p 1.5 0.320 0.345 1.4 54 - 80 72 - 107 114 - 170 202p 16 2p 1.5 0.505 0.550 2.2 126 - 187 154 - 230 219 - 326 13
4p 16 4p 1.5 0.625 0.675 2.7 200 - 298 234 - 349 314 - 467 11
8p 16 8p 1.5 0.785 0.850 3.4 356 - 530 399 - 594 498 - 740 8
10p 16 10p 1.5 0.930 1.010 4.0 461 - 686 512 - 761 628 - 935 8
12p 16 12p 1.5 0.960 1.040 4.2 519 - 772 571 - 850 692 - 1029 7
16p 16 16p 1.5 1.080 1.170 4.7 674 - 1003 733 - 1090 867 - 1290 6
20p 16 20p 1.5 1.210 1.310 5.2 834 - 1241 899 - 1338 1050 - 1562 6
24p 16 24p 1.5 1.355 1.465 5.9 1014 - 1509 1087 - 1618 1255 - 1868 5
27p 16 27p 1.5 1.385 1.500 6.0 1112 - 1655 1187 - 1766 1359 - 2022 5
36p 16 36p 1.5 1.565 1.695 6.8 1460 - 2172 1545 - 2298 1738 - 2587 4
8/10/2019 Tricab Marine Cables
24/58
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11
Insulation: LSFLEX
R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant,Low Smoke, Zero Halogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351) Splash resistant to oil,skydrol, gasoline, acid, sea water. Resists ozone andUV.
Screen: Individual and Collective Aluminium/Laminate Tape
Drain Wire:
Tinned annealed copper
Isolation Tape: Polyester
ssembly:Components cabled with filler asrequired and overall binder tape
Bedding Tape: Polypropylene
Braid/ rmor Options:
Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke, Zero Halogen (TPO/TPPO toIEEE-1580) (SHF-1 to IEC 60092-359) Splashresistant to oil, skydrol, gasoline, acid, sea water.Resists ozone and UV.
rmor (Optional):
All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING300 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNVTransport Canada Marine SafetyCable constructions, Jackets, and Inner
components to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
ASTM B3-01ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228IEC 60092-350IEC 60092-376IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
EG
22 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)- (kg/km) (lbs/kft)- (kg/km) (lbs/kft)-(kg/km) (Amps)
27p 18 27p .75 1.02 1.07 1.180 1.275 7.7 822 - 1223 886 - 1318 1033 - 1536 3
36p 18 36p .75 1.16 1.20 1.320 1.430 8.6 1048 - 1559 1119 - 1666 1283 - 1910 3
20p 18 20p .75 0.88 0.93 1.035 1.125 6.8 637 - 948 693 - 1032 823 - 1224 4
24p 18 24p .75 1.00 1.04 1.155 1.250 7.5 762 - 1134 825 - 1227 968 - 1441 3
12p 18 12p .75 0.70 0.74 0.845 0.915 5.5 423 - 629 469 - 698 575 - 855 4
16p 18 16p .75 0.79 0.83 0.935 1.015 6.1 528 - 786 579 - 862 696 - 1036 4
8p 18 8p .75 0.56 0.61 0.700 0.760 4.6 305 - 454 344 - 511 432 - 643 5
10p 18 10p .75 0.67 0.72 0.820 0.885 5.3 385 - 573 430 - 639 532 - 792 5
1p 18 1p .75 0.20 0.25 0.330 0.360 2.2 73 - 109 92 - 137 135 - 201 13
2p 18 2p .75 0.35 0.39 0.485 0.525 3.2 131 - 195 158 - 235 220 - 327 8
4p 18 4p .75 0.44 0.49 0.575 0.625 3.8 194 - 289 226 - 336 299 - 445 7
APPLICATIONFlexible Instrumentation cables suitable for all marine applications,where mechanical or EMC protectionis required. Where circuit integrity under fire conditions is required see FL series.
Flexible IEEE Marine Individual & CollectiveScreened Braided/Armored Instrumentation300V 110C LSZH
8/10/2019 Tricab Marine Cables
25/58
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 23
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)- (kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* TRIADS (t) TRIADS (t) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)- (kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
4t 14 4t 2.5 0.69 0.73 0.840 0.910 5.5 463 - 689 509 - 757 614 - 914 12
7t 14 7t 2.5 0.86 0.90 1.015 1.095 6.6 714 - 1062 769 - 1144 896 - 1333 11
1t 14 1t 2.5 0.31 0.36 0.445 0.485 2.9 143 - 213 168 - 250 225 - 335 25
3t 14 3t 2.5 0.62 0.67 0.770 0.830 5.0 385 - 573 427 - 636 524 - 779 17
4t 16 4t 1.5 0.59 0.64 0.740 0.805 4.8 351 - 522 392 - 583 485 - 722 8
7t 16 7t 1.5 0.74 0.78 0.890 0.965 5.8 530 - 789 579 - 861 690 - 1027 7
1t 18 1t .75 0.22 0.26 0.345 0.375 2.3 80 - 119 100 - 148 145 - 216 11
3t 18 3t .75 0.43 0.48 0.570 0.615 3.7 200 - 298 231 - 344 304 - 452 7
1t 16 1t 1.5 0.27 0.32 0.400 0.435 2.6 112 - 167 135 - 200 187 - 278 17
3t 16 3t 1.5 0.53 0.58 0.680 0.735 4.4 294 - 437 331 - 493 417 - 621 11
4t 18 4t .75 0.48 0.52 0.615 0.670 4.0 235 - 350 269 - 400 347 - 517 5
7t 18 7t .75 0.59 0.64 0.735 0.795 4.8 345 - 513 385 - 573 478 - 711 4
36p 14 36p 2.5 1.68 1.73 1.875 2.030 12.2 2276 - 3387 2377 - 3537 2608 - 3881 7
24p 14 24p 2.5 1.44 1.49 1.625 1.765 10.6 1616 - 2405 1704 - 2535 1905 - 2835 8
27p 14 27p 2.5 1.48 1.53 1.665 1.805 10.8 1759 - 2617 1849 - 2751 2055 - 3057 8
16p 14 16p 2.5 1.14 1.18 1.305 1.415 8.5 1098 - 1634 1169 - 1739 1331 - 1981 10
20p 14 20p 2.5 1.28 1.33 1.455 1.580 9.5 1342 - 1997 1421 - 2114 1601 - 2383 10
10p 14 10p 2.5 0.97 1.02 1.135 1.230 7.4 774 - 1152 836 - 1243 977 - 1453 12
12p 14 12p 2.5 1.01 1.05 1.170 1.270 7.6 862 - 1283 926 - 1377 1071 - 1594 11
4p 14 4p 2.5 0.63 0.68 0.780 0.840 5.0 364 - 542 407 - 605 504 - 751 17
8p 14 8p 2.5 0.81 0.85 0.965 1.045 6.3 607 - 903 660 - 981 780 - 1161 12
1p 14 1p 2.5 0.29 0.34 0.425 0.460 2.8 118 - 176 142 - 211 196 - 292 30
2p 14 2p 2.5 0.50 0.54 0.640 0.695 4.2 246 - 366 281 - 419 362 - 539 20
series
EGFlexible IEEE Marine Individual & CollectiveScreened Braided/Armored Instrumentation300V 110C LSZH
NUMBER OF NUMBER OF NOMINAL NOMINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
36p 16 36p 1.5 1.44 1.49 1.630 1.765 10.6 1669 - 2483 1757 - 2614 1958 - 2914 4
24p 16 24p 1.5 1.24 1.29 1.420 1.535 9.2 1195 - 1778 1272 - 1892 1447 - 2154 5
27p 16 27p 1.5 1.27 1.32 1.450 1.570 9.4 1297 - 1930 1375 - 2046 1555 - 2314 5
16p 16 16p 1.5 0.98 1.02 1.140 1.240 7.4 818 - 1217 880 - 1309 1022 - 1521 6
20p 16 20p 1.5 1.10 1.15 1.270 1.375 8.3 995 - 1481 1064 - 1583 1222 - 1818 6
1p 16 1p 1.5 0.25 0.30 0.385 0.415 2.5 95 - 141 117 - 174 166 - 247 20
2p 16 2p 1.5 0.43 0.48 0.570 0.620 3.7 195 - 290 227 - 337 299 - 445 13
10p 16 10p 1.5 0.84 0.88 0.995 1.075 6.5 584 - 869 638 - 950 762 - 1134 8
12p 16 12p 1.5 0.87 0.91 1.025 1.110 6.7 647 - 963 703 - 1046 831 - 1236 7
4p 16 4p 1.5 0.54 0.59 0.690 0.745 4.5 282 - 420 320 - 476 407 - 605 11
8p 16 8p 1.5 0.70 0.74 0.850 0.920 5.5 460 - 684 506 - 753 613 - 912 8
8/10/2019 Tricab Marine Cables
26/58
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11Available in plain or tinned
Flame Barrier: Fire Resistant, Halogen Free,Glass Mica Tape
Insulation: LSFLEX
R-30, Cross-linked, Polyolefinic,Thermoset, Flame Retardant, Low Smoke, ZeroHalogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351)Splash resistant to oil, skydrol, gasoline, acid, seawater. Resists ozone and UV. Includes ripcord on10mm2 and larger
ssembly:Conductors cabled with filler asrequired and overall binder tape orAluminum/ Polyester Shield + drain wire
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke,Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 to IEC60092-359) Splash resistant to oil, skydrol, gasoline,acid, sea water. Resists ozone and UV.
rmor (Optional):All constructions are available
with Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING600/1000 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNVTransport Canada Marine SafetyCable constructions, Jackets, and Inner
components to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Power and Control cables suitable for all marine applications, where circuit integrity is required underfire conditions. Where mechanical or EMC protection is required see BH series.
ASTM B3-01
ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228
IEC 60092-350IEC 60092-353IEC 60331IEC 60331-11IEC 60331-21IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
RR
24 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
Flexible IEEE MarineFire Resistant Power & Control0.6/1kV 110C LSZH
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF DIAMETER OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X INSULATION (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 (inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1c 10 1c 6 0.20 0.275 0.300 2.4 61 - 91 77 - 115 114 - 169 58
1c 8 1c 10 0.24 0.320 0.350 2.8 94 - 140 112 - 167 154 - 230 76
1c 6 1c 16 0.29 0.370 0.400 3.2 132 - 196 153 - 227 201 - 298 101
1c 4 1c 25 0.35 0.425 0.460 3.7 193 - 287 217 - 323 272 - 405 133
1c 2 1c 35 0.40 0.480 0.520 4.2 259 - 385 286 - 425 347 - 517 162
1c 1 1c 50 0.46 0.550 0.595 4.8 360 - 536 390 - 581 460 - 685 202
1c 2/0 1c 70 0.53 0.620 0.675 5.4 491 - 731 525 - 782 604 - 899 250
1c 3/0 1c 95 0.63 0.720 0.780 6.2 656 - 976 695 - 1035 786 - 1170 306
1c 236 McM 1c 120 0.68 0.775 0.840 6.7 797 - 1186 839 - 1249 937 - 1394 376
1c 296 McM 1c 150 0.79 0.885 0.960 7.7 1002 - 1491 1050 - 1563 1161 - 1728 412
1c 365 McM 1c 185 0.85 0.945 1.025 8.2 1220 - 1815 1272 - 1892 1390 - 2068 464
1c 473 McM 1c 240 0.95 1.050 1.140 9.1 1550 - 2306 1607 - 2392 1738 - 2587 579
1c 592 McM 1c 300 1.06 1.160 1.260 10.1 1905 - 2835 1968 - 2929 2113 - 3144 623
1c 789 McM 1c 400 1.19 1.300 1.410 11.3 2494 - 3711 2565 - 3816 2726 - 4057 785
1c 986 McM 1c 500 1.33 1.445 1.565 12.5 3134 - 4663 3212 - 4780 3391 - 5046 867
1c 1243 McM 1c 630 1.48 1.600 1.735 13.9 3917 - 5828 4003 - 5957 4201 - 6252 990
8/10/2019 Tricab Marine Cables
27/58
series
RR
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 25
Flexible IEEE MarineFire Resistant Power & Control0.6/1kV 110C LSZH
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
4c 6 4c 16 0.785 0.855 6.8 552 - 821 595 - 886 694 - 1033 74
4c 4 4c 25 0.930 1.005 8.0 816 - 1214 867 - 1290 983 - 1462 93
4c 2 4c 35 1.055 1.145 9.2 1097 - 1632 1154 - 1718 1286 - 1914 115
4c 1 4c 50 1.225 1.325 10.6 1537 - 2287 1603 - 2386 1756 - 2612 144
4c 2/0 4c 70 1.400 1.515 12.1 2101 - 3126 2177 - 3239 2350 - 3497 179
4c 3/0 4c 95 1.630 1.765 14.1 2827 - 4207 2915 - 4338 3117 - 4638 221
4c 236 McM 4c 120 1.765 1.915 15.3 3432 - 5107 3527 - 5248 3745 - 5573 255
4c 296 McM 4c 150 2.030 2.195 17.6 4344 - 6464 4453 - 6626 4703 - 6998 290
4c 365 McM 4c 185 2.175 2.360 18.9 5281 - 7858 5398 - 8032 5666 - 8432 33
5c 16 5c 1.5 0.455 0.495 4.0 120 - 179 146 - 217 204 - 304 14
5c 14 5c 2.5 0.515 0.555 4.4 165 - 246 194 - 288 259 - 385 22
5c 12 5c 4 0.570 0.620 5.0 226 - 336 258 - 383 330 - 491 26
5c 10 5c 6 0.630 0.685 5.5 302 - 449 337 - 501 417 - 620 34
5c 8 5c 10 0.750 0.815 6.5 474 - 705 515 - 767 610 - 908 43
5c 6 5c 16 0.875 0.950 7.6 681 - 1013 729 - 1085 839 - 1248 59
5c 4 5c 25 1.035 1.120 9.0 1008 - 1500 1064 - 1584 1194 - 1776 74
5c 2 5c 35 1.180 1.275 10.2 1357 - 2019 1421 - 2114 1568 - 2332 92
5c 1 5c 50 1.370 1.480 11.8 1903 - 2832 1977 - 2942 2147 - 3194 115
7c 16 7c 1.5 0.505 0.550 4.4 147 - 219 175 - 261 240 - 357 1212c 16 12c 1.5 0.670 0.730 5.8 251 - 373 288 - 429 373 - 555 9
19c 16 19c 1.5 0.795 0.860 6.9 368 - 548 412 - 612 511 - 761 9
24c 16 24c 1.5 0.940 1.015 8.1 503 - 748 554 - 825 672 - 999 8
27c 16 27c 1.5 0.960 1.040 8.3 530 - 789 582 - 867 702 - 1045 8
33c 16 33c 1.5 1.040 1.125 9.0 630 - 937 687 - 1022 816 - 1215 7
37c 16 37c 1.5 1.085 1.175 9.4 692 - 1030 751 - 1117 886 - 1318 7
7c 14 7c 2.5 0.570 0.615 4.9 203 - 302 234 - 349 307 - 456 20
12c 14 12c 2.5 0.760 0.820 6.6 350 - 521 392 - 583 487 - 724 14
19c 14 19c 2.5 0.900 0.970 7.8 517 - 769 566 - 842 678 - 1009 14
24c 14 24c 2.5 1.060 1.150 9.2 704 - 1048 762 - 1133 894 - 1331 13
27c 14 27c 2.5 1.085 1.175 9.4 747 - 1112 806 - 1199 942 - 1401 13
33c 14 33c 2.5 1.175 1.275 10.2 890 - 1324 954 - 1419 1100 - 1637 11
37c 14 37c 2.5 1.225 1.330 10.6 980 - 1458 1047 - 1557 1199 - 1784 11
2c 16 2c 1.5 0.355 0.385 3.1 65 - 97 85 - 127 132 - 196 20
2c 14 2c 2.5 0.395 0.430 3.4 86 - 128 108 - 161 160 - 238 312c 12 2c 4 0.440 0.480 3.8 115 - 171 140 - 208 196 - 292 40
2c 10 2c 6 0.485 0.525 4.2 150 - 223 177 - 263 239 - 356 50
2c 8 2c 10 0.575 0.625 5.0 229 - 341 261 - 388 334 - 497 67
2c 6 2c 16 0.665 0.725 5.8 324 - 482 361 - 537 445 - 662 91
2c 4 2c 25 0.785 0.850 6.8 473 - 704 516 - 768 615 - 915 113
2c 2 2c 35 0.890 0.965 7.7 632 - 940 681 - 1013 792 - 1179 142
3c 16 3c 1.5 0.380 0.410 3.3 80 - 119 101 - 151 150 - 224 17
3c 14 3c 2.5 0.420 0.455 3.6 108 - 161 132 - 196 186 - 277 28
3c 12 3c 4 0.470 0.510 4.1 147 - 219 173 - 258 233 - 347 33
3c 10 3c 6 0.515 0.560 4.5 194 - 289 223 - 331 289 - 429 43
3c 8 3c 10 0.615 0.665 5.3 301 - 448 335 - 498 413 - 614 54
3c 6 3c 16 0.710 0.770 6.2 430 - 640 469 - 698 559 - 832 74
3c 4 3c 25 0.840 0.910 7.3 633 - 942 679 - 1010 784 - 1167 93
3c 2 3c 35 0.950 1.030 8.2 849 - 1263 901 - 1341 1020 - 1518 115
3c 1 3c 50 1.105 1.195 9.6 1187 - 1766 1247 - 1855 1384 - 2060 144
3c 2/0 3c 70 1.260 1.365 10.9 1620 - 2411 1688 - 2512 1845 - 2745 179
3c 3/0 3c 95 1.470 1.590 12.7 2178 - 3241 2257 - 3359 2439 - 3630 221
3c 236 McM 3c 120 1.590 1.720 13.8 2641 - 3930 2727 - 4057 2923 - 4350 255
3c 296 McM 3c 150 1.825 1.975 15.8 3345 - 4977 3443 - 5123 3668 - 5459 290
3c 365 McM 3c 185 1.955 2.120 17.0 4060 - 6041 4165 - 6198 4407 - 6557 330
3c 473 McM 3c 240 2.185 2.365 18.9 5158 - 7675 5275 - 7850 5545 - 8251 401
3c 592 McM 3c 300 2.420 2.625 21.0 6349 - 9447 6479 - 9641 6777 - 10085 440
4c 16 4c 1.5 0.415 0.450 3.6 99 - 147 122 - 182 176 - 261 17
4c 14 4c 2.5 0.465 0.500 4.0 136 - 202 162 - 241 221 - 329 28
4c 12 4c 4 0.515 0.560 4.5 185 - 275 214 - 318 280 - 416 33
4c 10 4c 6 0.570 0.615 4.9 246 - 366 278 - 413 350 - 520 43
4c8 4c 10 0.675 0.735 5.9 385 - 573 422 - 628 508 - 755 54
8/10/2019 Tricab Marine Cables
28/58
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11Available in plain or tinned
Flame Barrier: Fire Resistant, Halogen Free,Glass Mica Tape
Insulation: LSFLEX
R-30, Cross-linked, Polyolefinic,Thermoset, Flame Retardant, Low Smoke,Zero Halogen (LSX to IEEE-1580) (HF-90 toIEC 60092-351) Splash resistant to oil, skydrol,gasoline, acid, sea water. Resists ozone and UV.Includes ripcord on 10mm2 and larger
ssembly:Conductors cabled with filler asrequired and overall binder tape
Bedding Tape: Polypropylene
Braid/ rmor Options:
Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%)(also available with drain wire under braid)
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke,
Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 toIEC 60092-359) Splash resistant to oil, skydrol,gasoline, acid, sea water. Resists ozone and UV.
rmor (Optional):
All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING600/1000 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNV
Transport Canada Marine SafetyCable constructions, Jackets, and Innercomponents to UL 1309 - CSA C22.2 No. 245for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATION
Flexible Power and Control cables suitable for all marine applications, where circuit integrity is required under
fire conditions and mechanical or EMC protection is also required.
ASTM B3-01ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228IEC 60092-350IEC 60092-353IEC 60331IEC 60331-11IEC 60331-21IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
BH
26 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NOMINAL NOMIINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
1c 10 1c 6 0.22 0.26 0.345 0.375 3.8 97 - 144 117 - 174 162 - 241 58
1c 8 1c 10 0.26 0.31 0.390 0.425 4.3 136 - 202 158 - 235 209 - 311 76
1c 6 1c 16 0.30 0.35 0.440 0.475 4.8 181 - 269 206 - 306 262 - 390 101
1c 4 1c 25 0.36 0.41 0.495 0.540 5.4 250 - 372 278 - 413 341 - 508 133
1c 2 1c 35 0.41 0.46 0.550 0.595 6.0 322 - 479 352 - 524 422 - 629 162
1c 1 1c 50 0.48 0.53 0.620 0.670 6.7 434 - 646 468 - 697 547 - 814 202
1c 2/0 1c 70 0.55 0.60 0.690 0.750 7.5 574 - 854 612 - 911 699 - 1041 250
1c 3/0 1c 95 0.64 0.69 0.790 0.855 8.6 753 - 1120 796 - 1185 895 - 1332 306
1c 236 McM 1c 120 0.70 0.74 0.845 0.915 9.2 901 - 1341 947 - 1409 1053 - 1567 376
1c 296 McM 1c 150 0.80 0.85 0.955 1.035 10.4 1121 - 1668 1173 - 1745 1292 - 1923 412
1c 365 McM 1c 185 0.86 0.91 1.015 1.100 11.0 1348 - 2006 1403 - 2088 1530 - 2277 464
1c 473 McM 1c 240 0.96 1.01 1.120 1.215 12.2 1692 - 2518 1753 - 2608 1893 - 2816 579
1c 592 McM 1c 300 1.07 1.12 1.235 1.335 13.4 2062 - 3068 2129 - 3168 2282 - 3396 623
1c 789 McM 1c 400 1.20 1.25 1.370 1.485 14.9 2671 - 3974 2745 - 4085 2915 - 4338 785
1c 986 McM 1c 500 1.34 1.39 1.515 1.640 16.4 3329 - 4954 3411 - 5075 3598 - 5355 867
1c 1243 McM 1c 630 1.49 1.54 1.670 1.810 18.1 4134 - 6151 4224 - 6285 4431 - 6593 990
Flexible IEEE Marine Fire ResistantBraided/Armored Power & Control0.6/1kV 110C LSZH
8/10/2019 Tricab Marine Cables
29/58
series
BH
i s s u e 2 . 8 T r i c a b f l e x i b l e M a r i n e C a b l e s 27* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
Flexible IEEE Marine Fire ResistantBraided/Armored Power & Control0.6/1kV 110C LSZH
NUMBER OF NOMINAL NOMIINAL OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* CONDUCTORS (c) OD OVER OD OVER DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X BEDDING BRAID (Inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG/kcmil mm2 (Inches) (Inches) Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
4c 236 McM 4c 120 1.65 1.70 1.835 1.990 19.9 3512 - 5226 3611 - 5373 3838 - 5711 255
4c 296 McM 4c 150 1.91 1.95 2.100 2.270 22.7 4406 - 6556 4519 - 6724 4778 - 7109 290
4c 365 McM 4c 185 2.05 2.09 2.245 2.435 24.4 5332 - 7934 5453 - 8114 5730 - 8526 330
5c 16 5c 1.5 0.39 0.43 0.525 0.570 5.7 173 - 257 202 - 301 270 - 401 14
5c 14 5c 2.5 0.44 0.49 0.585 0.630 6.3 224 - 333 256 - 381 330 - 491 22
5c 12 5c 4 0.50 0.54 0.640 0.695 7.0 290 - 432 325 - 484 407 - 605 26
5c 10 5c 6 0.56 0.60 0.700 0.760 7.6 371 - 552 410 - 609 498 - 741 34
5c 8 5c 10 0.67 0.72 0.820 0.890 8.9 553 - 823 598 - 890 701 - 1043 43
5c 6 5c 16 0.80 0.84 0.945 1.025 10.3 769 - 1144 821 - 1221 939 - 1397 59
5c 4 5c 25 0.95 0.99 1.105 1.200 12.0 1105 - 1644 1165 - 1734 1303 - 1939 74
5c 2 5c 35 1.08 1.13 1.250 1.350 13.5 1461 - 2174 1529 - 2275 1684 - 2505 92
5c 1 5c 50 1.27 1.31 1.440 1.560 15.6 2013 - 2995 2091 - 3111 2269 - 3376 115
7c 16 7c 1.5 0.43 0.48 0.570 0.620 6.2 211 - 314 243 - 361 315 - 469 1212c 16 12c 1.5 0.59 0.63 0.735 0.800 8.0 335 - 498 375 - 559 468 - 697 9
19c 16 19c 1.5 0.71 0.75 0.860 0.930 9.3 470 - 699 517 - 769 625 - 929 9
24c 16 24c 1.5 0.84 0.89 1.005 1.085 10.9 619 - 921 674 - 1002 799 - 1189 8
27c 16 27c 1.5 0.86 0.91 1.025 1.110 11.1 652 - 970 708 - 1053 836 - 1243 8
33c 16 33c 1.5 0.94 0.99 1.105 1.195 12.0 763 - 1135 823 - 1225 960 - 1429 7
37c 16 37c 1.5 0.98 1.03 1.145 1.240 12.4 832 - 1238 894 - 1331 1037 - 1543 7
7c 14 7c 2.5 0.49 0.54 0.630 0.685 6.9 276 - 411 311 - 463 391 - 582 20
12c 14 12c 2.5 0.67 0.72 0.820 0.890 8.9 445 - 662 490 - 729 593 - 882 14
19c 14 19c 2.5 0.81 0.85 0.960 1.040 10.4 634 - 943 686 - 1021 807 - 1200 14
24c 14 24c 2.5 0.96 1.01 1.125 1.220 12.2 837 - 1245 898 - 1336 1038 - 1545 13
27c 14 27c 2.5 0.99 1.03 1.150 1.245 12.5 885 - 1317 947 - 1410 1091 - 1623 13
33c 14 33c 2.5 1.07 1.12 1.240 1.345 13.5 1042 - 1550 1109 - 1651 1264 - 1880 11
37c 14 37c 2.5 1.12 1.17 1.290 1.400 14.0 1140 - 1696 1210 - 1800 1370 - 2039 11
2c 16 2c 1.5 0.29 0.34 0.425 0.460 4.6 103 - 153 127 - 189 182 - 271 20
2c 14 2c 2.5 0.33 0.38 0.465 0.505 5.1 128 - 190 154 - 229 214 - 319 31
2c 12 2c 4 0.37 0.42 0.510 0.555 5.6 160 - 238 188 - 280 254 - 378 40
2c 10 2c 6 0.42 0.46 0.555 0.600 6.0 198 - 295 229 - 340 299 - 445 50
2c 8 2c 10 0.50 0.55 0.645 0.700 7.0 283 - 421 319 - 474 400 - 595 67
2c 6 2c 16 0.59 0.64 0.735 0.800 8.0 383 - 570 423 - 630 516 - 768 91
2c 4 2c 25 0.71 0.75 0.855 0.925 9.3 537 - 799 584 - 869 691 - 1028 113
2c 2 2c 35 0.81 0.85 0.960 1.040 10.4 698 - 1039 750 - 1117 870 - 1295 142
3c 16 3c 1.5 0.31 0.36 0.450 0.485 4.9 122 - 182 147 - 219 205 - 305 17
3c 14 3c 2.5 0.35 0.40 0.490 0.535 5.4 154 - 229 181 - 270 244 - 364 28
3c 12 3c 4 0.40 0.45 0.540 0.585 5.9 197 - 293 227 - 338 296 - 440 33
3c 10 3c 6 0.45 0.49 0.585 0.635 6.4 248 - 369 280 - 417 355 - 528 43
3c 8 3c 10 0.54 0.59 0.685 0.740 7.4 362 - 539 400 - 595 486 - 723 54
3c 6 3c 16 0.64 0.68 0.780 0.850 8.5 497 - 740 540 - 803 638 - 950 74
3c 4 3c 25 0.76 0.80 0.910 0.985 9.9 706 - 1051 756 - 1124 869 - 1294 93
3c 2 3c 35 0.87 0.91 1.020 1.110 11.1 926 - 1378 982 - 1461 1109 - 1651 115
3c 1 3c 50 1.01 1.06 1.175 1.270 12.7 1266 - 1884 1330 - 1979 1476 - 2196 144
3c 2/0 3c 70 1.16 1.21 1.330 1.440 14.4 1698 - 2527 1770 - 2634 1935 - 2879 179
3c 3/0 3c 95 1.37 1.41 1.540 1.665 16.7 2251 - 3349 2334 - 3473 2525 - 3756 221
3c 236 McM 3c 120 1.48 1.53 1.660 1.795 18.0 2709 - 4031 2798 - 4164 3004 - 4470 255
3c 296 McM 3c 150 1.71 1.76 1.895 2.050 20.5 3397 - 5055 3499 - 5206 3733 - 5554 290
3c 365 McM 3c 185 1.84 1.88 2.025 2.195 22.0 4101 - 6102 4210 - 6265 4460 - 6637 330
3c 473 McM 3c 240 2.06 2.10 2.255 2.445 24.5 5175 - 7700 5296 - 7881 5574 - 8294 401
3c 592 McM 3c 300 2.29 2.33 2.490 2.700 27.0 6334 - 9425 6468 - 9624 6775 - 10081 440
4c 16 4c 1.5 0.35 0.39 0.485 0.525 5.3 147 - 219 174 - 259 236 - 351 17
4c 14 4c 2.5 0.39 0.44 0.535 0.580 5.8 187 - 278 217 - 322 285 - 424 28
4c 12 4c 4 0.44 0.49 0.585 0.635 6.4 242 - 360 274 - 408 349 - 519 33
4c 10 4c 6 0.50 0.54 0.640 0.690 6.9 307 - 457 342 - 509 423 - 629 43
4c8 4c 10 0.60 0.65 0.745 0.810 8.1 454 - 676 495 - 737 589 - 876 54
4c 6 4c 16 0.71 0.75 0.860 0.930 9.3 628 - 934 675 - 1004 782 - 1164 74
4c 4 4c 25 0.84 0.89 1.000 1.080 10.8 898 - 1336 952 - 1417 1077 - 1603 93
4c 2 4c 35 0.97 1.01 1.125 1.220 12.2 1184 - 1762 1245 - 1853 1385 - 2061 115
4c 1 4c 50 1.13 1.17 1.295 1.400 14.0 1627 - 2421 1697 - 2525 1858 - 2765 1444c 2/0 4c 70 1.30 1.34 1.470 1.590 15.9 2191 - 3260 2270 - 3378 2452 - 3649 179
4c 3/0 4c 95 1.52 1.57 1.700 1.845 18.5 2912 - 4333 3004 - 4470 3214 - 4783 221
8/10/2019 Tricab Marine Cables
30/58
CONSTRUCTIONConductor: Finely stranded annealed copperto ASTM B3-01, ASTM B33-00 and IEC 60228.Significantly exceeds IEEE-1580 Table 11
Flame Barrier: Fire Resistant, Halogen Free,Glass Mica Tape
Insulation: LSFLEX
R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant,Low Smoke, Zero Halogen (LSX to IEEE-1580)(HF-90 to IEC 60092-351) Splash resistant to oil,skydrol, gasoline, acid, sea water. Resists ozone andUV.
ssembly:Components cabled with filler asrequired and overall binder tape
Screen:Aluminium/Laminate Tape
Drain Wire: Tinned annealed copper
Binder Tape: Polyester
Ripcord: High strength ripcord under jacket
Jacket: LSFLEX
S-50, Polyolefinic, FlameRetardant, Low Smoke, Zero Halogen (TPO/TPPO toIEEE-1580) (SHF-1 to IEC 60092-359) Splashresistant to oil, skydrol, gasoline, acid, sea water.
Resists ozone and UV. rmor (Optional):All constructions are availablewith Overbraid Armor of either Aluminum or Bronze.Add 0.05 to OVERALL DIAMETER in tables.
OPERATING TEMP-40C to +110C
VOLTAGE RATING300 Volts
CORE IDENTIFICATIONTo customer specification
JACKET COLORTo customer specification
STANDARDS
APPROVALSUSCG, ABS, LR, DNVTransport Canada Marine SafetyCable constructions, Jackets, and Innercomponents to UL 1309 - CSA C22.2 No. 245
for Cold Bend (-40C) and Cold Impact (-35C)
APPLICATIONFlexible Instrumentation cables suitable for all marine applications, where circuit integrity is required underfire conditions. Where mechanical or EMC protection is required see FJ series.
ASTM B3-01ASTM B33-00
IEEE-45IEEE-1580IEEE-1202
IEC 60228IEC 60092-350
IEC 60092-376IEC 60331IEC 60331-11IEC 60331-21IEC 60332-1IEC 60332-3-22 Cat AIEC 60754-1&2IEC 61034-1&2
series
ES
28 T r i c a b f l e x i b l e M a r i n e C a b l e s i s s u e 2 . 8
Flexible IEEE Marine Fire ResistantCollective Screened Instrumentation300V 110C LSZH
* Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked, @ 45C ambient.
NUMBER OF NUMBER OF OVERALL MINIMUM APPROX. APPROX. APPROX. AMPACITY* PAIRS (p) PAIRS (p) DIAMETER BENDING WEIGHT WEIGHT WEIGHT AT 90C X X (inches) RADIUS No Overbraid w/ Aluminum w/ Bronze
AWG mm2 Min Max (Inches) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (lbs/kft)-(kg/km) (Amps)
16p 18 16p .75 1.030 1.115 8.9 453 - 674 509 - 757 637 - 948 4
20p 18 20p .75 1.150 1.245 10.