34
Telephone: +64 9 963 2700 Facsimile: +64 9 963 2701 Email: [email protected] Website: www.projectmax.co.nz Condition Assessment and Rehabilitation Pump Station 5 Gravity Mains

Trunk Main Case Study - Typepad

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Trunk Main Case Study - Typepad

Telephone: +64 9 963 2700Facsimile: +64 9 963 2701Email: [email protected]:www.projectmax.co.nz

Condition Assessment and RehabilitationPump Station 5 Gravity Mains

Page 2: Trunk Main Case Study - Typepad

North Shore City

WWTP

PS5

Page 3: Trunk Main Case Study - Typepad

Pump Station No.5

• Daily flows: 20,000 to 60,000 cum/day. • Storage: 6,500cum

Pumps Flowrate (l/s)1 350-420l/s2 650l/s3 1,100l/s

Page 4: Trunk Main Case Study - Typepad

Rising Mains

PS5

View Rd

Page 5: Trunk Main Case Study - Typepad

Gravity Main

Page 6: Trunk Main Case Study - Typepad

Hydrogen Sulphide Attack

Page 7: Trunk Main Case Study - Typepad

View Rd

Page 8: Trunk Main Case Study - Typepad

Surface Damage

Page 9: Trunk Main Case Study - Typepad

Surface Damage Location

Page 10: Trunk Main Case Study - Typepad

Gravity Main

Page 11: Trunk Main Case Study - Typepad

Areas of Hydrogen Sulphide Attack

• Near Manholes• Bends• Debris in sewer

Page 12: Trunk Main Case Study - Typepad

Dig Up Samples

Page 13: Trunk Main Case Study - Typepad

Areas of Hydrogen Attack

Page 14: Trunk Main Case Study - Typepad

View Rd Trunk

Page 15: Trunk Main Case Study - Typepad

Cured-in-place Pipe

Page 16: Trunk Main Case Study - Typepad

Pump Station No.5

• Daily flows: 20,000 to 60,000 cum/day. • Storage: 6,500cum

Pumps Flowrate (l/s)1 350-420l/s2 650l/s3 1,100l/s

Page 17: Trunk Main Case Study - Typepad

Backflowing through rising main

Page 18: Trunk Main Case Study - Typepad

Bypass Pumping

Page 19: Trunk Main Case Study - Typepad

Bypass Pumping

Page 20: Trunk Main Case Study - Typepad

Pump Trials

• Pumps less efficient than expected• Leak in bypass main• Practiced contingency measures

Page 21: Trunk Main Case Study - Typepad

CIPP Lining

Page 22: Trunk Main Case Study - Typepad

CIPP Lining

Page 23: Trunk Main Case Study - Typepad

Finished Liner

Page 24: Trunk Main Case Study - Typepad

Stage 2 Rehabilitation

Page 25: Trunk Main Case Study - Typepad

Issues

• Minimise Reduction of Cross Sectional Area

• Minimise Impact on Residents & Public • Minimise Risk of Sewer Overflows • Track Record and Experience• Cost

Page 26: Trunk Main Case Study - Typepad

Options Considered - Discounted

Option IssuesCIPP Bypass pumpingOpen Cut Excavation Disruption. Higher CostSliplining Long lead in pitsSpayed Coating Non-structuralShort Patch Liner Turbulent flow at end of patchTroliner Unproven in New Zealand

Installer not experience with NSCC

Page 27: Trunk Main Case Study - Typepad

Item Spiral Wound Liner Segmented Slip Lining

Reduction in Diameter 74mm liner can accommodate changes indiameter & minor deviations in pipe alignment.This relates to 88 % X sectional area of ex pipe.

• 80mm (20mm thickness & 20mmannulus). If the pipes are straight thenreduction in ID will be similar to SpiralWound Liner.

• If the ex host pipe deviates the IDreduction will be more. For example a 1ºdeflection will equate to 80 % of Xsectional area.

Impact on Residents • Access required to each manhole for Oneor Two days.

• Minimal excavation required ( possibleremoval of MH throat & cover ).

• Equipment can be removed at the end ofeach working day.

• 7m long launching pits required to beexcavated at 5 locations. 2 located onprivate property, 3 in road reserve butvery close to private property.

• Launch pits required for up to a week ateach location.

• Pits can be covered at the end of eachday but some equipment & materials willremain.

Risk of Overflows • Can be installed during pump shut downperiods.

• Equipment can be removed & flowsrecommenced with 30 min warning.

Similar to Spiral Wound Liner

Track Record & Relevant Experience • 1 project completed in NZ ( Hastings ).• Used extensively in Aust.• An experienced installation crew would

be mobilized from Aust.

• Similar work has not been usedundertaken in NZ.

• Segmented Slip Lining with GRP pipeshas been used extensively in India &Europe.

• Maskells ( the proposed pipemanufacturer) can call on experience inEurope through their relationship withTrueflow.

Page 28: Trunk Main Case Study - Typepad

Item Spiral Wound Liner Segmented Slip Lining

Cost < $2,000 / m based on rates submitted for ViewRd lining Contract.

Estimated rate is $2,120 / m.

Risk Least Risk.• Contractor experienced with rehabilitation

method• Liner to accommodate changes in pipe

diameter & alignment.

Most Risk.• Contractor not experienced in installation

method• Construction delays possible which could

cause issues with residents & public• Cost overrun & variation claims possible.• Cross sectional area of liner may need to

be decreased to accommodate variationsin pipe alignment. Extent cannot beconfirmed until prover pulled throughpipe.

• Residents may object to largeexcavations on their properties.

• Resource Consent may be required forNoise.

Page 29: Trunk Main Case Study - Typepad

Spiral Wound Liner Selected

• Proven method with experienced contractor• Reduction in Cross Sectional area known and not

affected by variations in host pipe alignment.• Far less disruption to residents & public• Less risk of cost or time over runs.• Expected to be the cheapest option.

Page 30: Trunk Main Case Study - Typepad

Rotoloc – Liner Installation

Page 31: Trunk Main Case Study - Typepad

Rotoloc - Grouting

Page 32: Trunk Main Case Study - Typepad

Issues

• Man-Entry required• Flows Shutdown• Bends• Change in Diameter

Page 33: Trunk Main Case Study - Typepad

Summary

• Condition assessment, risk approach• Select the most appropriate method for

each circumstance• Construction & maintenance practices

can influence H2S• Bypass Pumps do no perform as

expected• Trial everything

Page 34: Trunk Main Case Study - Typepad

Summary

• The bigger the pipe, the more complex the rehabilitation