Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
PRODUCT DESCRIPTIONRmax TSP-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded to glass fiber reinforced aluminum foil facers on each side. TSP-3 utilizes a CFC-, HCFC- and HFC-free blowing agent that has zero Ozone Depletion Potential (ODP) and negligible Global Warming Potential (GWP). This insulation is suitable for use in walls, ceilings and some limited roofing applications in new construction for commercial, residential, agricultural and industrial buildings and in thermal retrofit construction within existing buildings.
COmPlIaNCES• ASTMC1289TypeI,Class1• InternationalBuildingCode(IBC)Section2603,FoamPlastic
• ASHRAE90.1• Miami-DadeCountyProductControlApproved
• CaliforniaCodeofRegulations,Title24
CONSTRUCTION aPPlICaTIONS• Studwalls;cavitywalls;masonrywalls;exteriorstucco;re-siding;vaultedceilings;atticsandcrawlspaces;limitedroofingapplications;laminate panel projects
INCENTIvE OPPORTUNITIES• Reducesenergycosts• ContributestowardLEED® credits• Offerstaxcredits,whereapplicable
TYPICal PHYSICal PROPERTIESPhysical properties shown are based on data obtained under controlled conditions and are subject to normal manufacturing tolerances.
Property TestMethod ResultsDensity,Overall,Nominal ASTMD1622 2.0pcfCompressiveStrength ASTMD1621 20psi1
Flame Spread, Core2 ASTME84 75orLessSmokeDeveloped,Core2 ASTME84 <450Water Vapor Transmission ASTME96 <0.3permWaterAbsorption ASTMC209 <1%Vol.Dimensional Stability ASTMD2126,
7days,158°F,98%rh<2%LinearChange
ServiceTemperatures -40°Fto+250°F
1Alsoavailablein25psiuponrequest. 2Flame spread and smoke numbers are shown for comparison purposes only and are not intended to represent the performance of TSP-3 and related components under actual fire conditions.
TSP-3Insulation for the Building Envelope
ROOF
WALL
SPECIALTY
Doing one thing well in so many ways...Rmax is a U.S. owned company that only manufactures polyiso insulation. TSP-3 is manufactured in the U.S. and is offered through anextensivedistributionnetwork.Itisavailableinstandard four foot wide panels, with standard panel lengths of eight or nine feet. Customlengthsareavailablefor special orders. Contact Rmax Sales at your regional CustomerServiceCenterforproductavailability,pricing information, and your nearest distribution center.
Corporate & TechnicalRmaxOperating,LLC13524WelchRoadDallas, Texas 75244-5291Phone: (972) 387-4500Fax: (972) 387-4673Email:[email protected]: www.rmax.com
Customer Service &Plant locationsCentral Region Dallas, Texas(800) 527-0890 Ext. 102Eastern RegionGreer, South Carolina (800) 845-4455 Ext. 156Western Region Fernley,Nevada (800) 762-9462 Ext. 156
THERmal PROPERTIES / PRODUCT DaTa “R”meansresistancetoheat flow.Thehigher theR-value,the greater the insulating power.
NominalThickness
Thermal R-Value1
R/Inch System R-Value2
Inches °F•ft2•hr/Btu °F•ft2•hr/Btu•in
°F•ft2•hr/Btu
1.00 6.0 6.00 8.771.50 9.6 6.40 12.372.00 13.1 6.55 15.872.50 16.7 6.68 19.473.00 20.3 6.77 23.073.50 23.9 6.83 26.674.00 27.4 6.85 30.174.50 31.0 6.89 33.77
1ThermalvaluesaredeterminedbyusingASTMC518testmethodat75°FmeantemperatureonmaterialconditionedaccordingtoPIMATechnicalBulletinNo.101. 2IncludestheASHRAEassigned2.77R-valueofa¾”dead-airspaceagainstareflectivefoilinatypicalwallassembly.
TSP-3isshippedinbundlesthatareapproximately48inches high and wrapped in plastic for easy handling. Visit www.rmax.com/resources.asp for a complete list of thicknesses and packaging information.
2011-12
Masonry Wall Construction - TSP-3 is applied to either the exterior orinteriorfaceofconcreteorconcretemasonrywallstoprovidealayerofcontinuousinsulation(ci)overtheentiresurface.Itmaybesecuredtotheinsidefaceofaconcreteorconcretemasonrywall,overorunderthefurringstrips,andcoveredwithaminimum1/2"gypsumwallboardinteriorfinish.Adhesives,screwsornailsmaybeusedtoholdtheTSP-3inplaceagainst the wall temporarily, until the furring strips and gypsum wallboard are installed. The furring strips and gypsum wallboard must be secured with suitable screws or nails.
05Masonary Wall ConstructionTSP-3 Interior Application A1.00
TSP - 3
1/2" GYSUM WALLBOARD
TREATED WOODFURRING 16" O.C.
CMU WALL
TREATED WOODFURRING AT BASE
TREATED WOODEND CAP
FOUNDATION WALL
Exterior Stucco Construction - TSP-3 may be used as the insulativesheathingunderhardcoatstuccofinishes.Itmaybesecuredto the studs with bugle-head screws, galvanized roofing nails orcommon-nails driven through cap washers. Cover the TSP-3 with asuitable separation layer such as an organic or inorganic felt. Then, attachconventionalmetalwirelathandexpansionjointswithappropriatefasteners as dictated by the local Building Code. Rmax does notrecommend the direct attachment of stucco, such as Portland cement or polymer-modified types, directly to the face of the insulation product. Consult stucco manufacturers for details.
06Stucco ConstructionTSP-3 Exterior Application A1.00
TSP - 3
ORGANIC / INORGANICFELT
METAL FLASHING
HARD COAT STUCCO
FOUNDATION WALL
SUBFLOORING &FLOOR FRAMING
TERMITE SHIELD
VAPOR RETARDER(if required)
METAL LATHE
FLASHING TAPE
1/2" GYPSUMWALLBOARD
Notes:1. Stud walls must be properly braced for lateral loadsaccording to the requirements of local Building Codes.
aPPlICaTION / INSTallaTIONStud Wall Construction - TSP-3 applied to the exterior or interior faceofstuds, tocoverallstuds,sills,platesandheaderconstructions,provides a layer of continuous insulation (ci) over details not normallycovered by insulation products. It may be secured to the framing orstructuralsheathingwithbugle-headscrews,galvanizedroofingnailsorcommon nails driven through cap washers. Quality-grade constructionadhesivesmayalsobeusedtosecuretheTSP-3oninteriorapplications.Exterior facades may include brick/stone veneer, exterior siding andstucco. TSP-3 must be covered on the interior with a minimum 1/2"gypsum wallboard interior finish that is mechanically attached.
02Stud Wall Construction (Brick Veneer)TSP-3 Exterior Application A1.00
TSP - 3
AIR / WATER RESISTIVEBARRIER (if required)
FLASHING TAPE
BRICK VENEER (Provideweeps as required)
THRU-WALL FLASHING(Metal)
SUBFLOORING &FLOOR FRAMING
BRICK TIES AS REQ.
TREATED WOOD
TERMITE SHIELD
VAPOR RETARDER(if required)
FOUNDATION WALL
1/2" GYPSUMWALLBOARD
Notes:1. Stud walls must be properly braced for lateral loadsaccording to the requirements of local Building Codes.
Cavity Wall Construction (Brick Veneer) - TSP-3 is an excellent cavityinsulationproductfittingbetweenthemasonryblockandfinishedbrickveneerofanyresidentialorcommercialproject.Itmaybesecuredtothedryfaceofthemasonryblockwallwithaqualitygradeconstructionadhesive.TSP-3canbecuttofitbetweenmasonryjointreinforcementsplacedtotiethebrickveneertotheconcreteblockback-upandinstalledhorizontally in strips to allow the wall ties to extend beyond the face of the insulationleavingtheproperairspacesasrequired.
04Cavity Wall Construction (Brick Veneer)TSP-3 Exterior Application A1.00
TSP - 3
16" OR 24' WIDTHS AVAILABLETO FIT BETWEEN MASONRYWALL TIES OR IMPALEINSULATION OVER WALLTIE PENTILES
BRICK VENEER (Provideweeps as required)
THRU-WALL FLASHING(Metal)
BRICK LEDGE
CMU WALL
FOUNDATION WALL
FLASHING TAPE
TSP-3
Re-Siding Construction - TSP-3 may be used in retrofit construction providedtheexistingsiding issoundandsolidlyattached. It issecuredwith galvanized nails of sufficient length to penetrate the old sidings,sheathings below and at least one inch into the existing wall studs. Then, cover the TSP-3 with a suitable new siding of aluminum, vinyl, fibercement, wood or wood fiber based products.
03Re-Siding ConstructionTSP-3 Exterior Application A1.00
EXISTING SHEATHINGAND SIDING SEENOTE #1
AIR / WATER RESISTIVEBARRIER (if required)
EXTERIOR SIDING
FLASHING TAPE
METAL FLASHING
TREATED WOOD
FOUNDATION WALL
SUBFLOORING &FLOOR FRAMING
VAPOR RETARDER(if required)
FOUNDATION
TSP - 3
Notes:1. Existing siding must be inspected and re-nailed to providefor solid back-up to attach new sheathing and sidingmaterials. Deteriorated or rotted areas of existing sidingmust be removed and replaced to restore original thickness.2. Stud walls must be properly braced for lateral loadsaccording to the requirements of local Building Codes.
TERMITE SHIELD
1/2" GYPSUMWALLBOARD
Vaulted Ceiling Construction - TSP-3 may be applied to the insidefaceoftheroofraftersinvaultedceilingconstructiontoprovidealayerofcontinuous insulation(ci)and increase theR-valueof theroof.Simply nail theTSP-3 to the face of the rafter, coverwith aminimum 1/2"gypsumwallboardandfinish.
07Stud Wall & Vaulted Ceiling ConstructionTSP-3 Interior Application A1.00
ROOF JOIST / RAFTER
STUD WALL
1/2" GYPSUMWALLBOARD
TSP - 3
Notes:1. Refer to local building codesfor requirements on proper ventilation2. Stud walls must be properly braced forlateral loads according to the requirements oflocal Building Codes.
VAPOR RETARDER(if required)
EXTERIOR WOODSHEATHING
Attics and Crawl Spaces - TSP-3 may be applied to the interior face of stud walls or roof rafters within attics and crawl spaces to providealayerofcontinuousinsulation(ci).SimplynailtheTSP-3totheframingmembers and coverwith an approved ignition barrier such as3/8" gypsumwallboardor 1/4"woodstructural panel, particleboardorhardboard.
Roofing Construction-TSP-3islaidoverasuitableroofdecksuchastongue-and-groovetimber,plywoodormetaldeckandcoveredwithasuitablelayerofplywood,waferboardorOSB.Asphaltorwoodshingles,concrete or clay tiles or a standing seam metal roof may be installed overtheinsulatedroofdeckaccordingtotheroofingsysteminstructions.NOTE: Itmaynot benecessary to cover the insulationwithanailablesurface when used under a standing seam metal roof assembly, consult manufacturer for details.
10Asphalt Shingle Roof ConstructionTSP-3 Exterior Application A1.00
UNDERLAYMENT
ASPHALT SHINGLEROOFING SYSTEM
NAILABLE SURFACE
TSP - 3
VAPOR RETARDER(if required)
STRUCTURALROOF DECK
WOOD RAFTER ORTRUSS
FASCIA
Notes:1. Consult shingle manufacturer for above deckroofing ventilation requirements.
lImITaTIONS
TSP-3 is not recommended, nor warranted, for use as a commercial roof insulation directly under membrane systems. Consult Rmax Sales for suitable commercial roof insulation products.
TSP-3isnotastructuralpanel.Itmustnotbeusedasanailingbaseforany other building products. Furthermore, stud walls insulated with TSP-3 mustbeproperlybracedforlateralloadsaccordingtotherequirementsoflocalBuildingCodes.
WaRNINGDO NOT leave TSP-3 exposed. Polyiso foam is an organic materialwhich will burn when exposed to an ignition source of sufficient heat and intensity and may contribute to flames spreading.
InstallationsutilizingTSP-3must be fully protectedon the interior sideof thebuildingbyathermalbarriersuchasaminimumof1/2"gypsumwallboard.Masonryorconcrete that isaminimumof1" thick,plywoodthatisaminimumof1/2"thickandwoodthatisaminimumof1"nominalthickness may also be recognized as suitable thermal barriers. Consult yourlocalBuildingOfficialforspecificgoverningcodesandrequirements.
The interior and/or exterior of the building should be protected with a suitablevaporretarderand/orawaterresistivebarrier,ifrequired,basedonlocalBuildingCodesandclimatezone.
WaRRaNTYSee Rmax “Sales Policy” for warranty conditions. Rmax does not assume any responsibility or liability for the performance of any products other than those manufactured by Rmax. NOTE: All Rmax products must be tarped, placed on skids and kept dry before and throughout construction.
For warranties, limitations and conditions refer to Rmax Sales Policy and applicable warranties. All documents are located at www.rmax.com. For technical and sales support, email [email protected] or call (800) 527-0890.
Proudly Made and Engineered in the U.S.A.
Rmax Sales Offices and Plant Locations
E-mail us at [email protected] or visit our website www.rmax.com
Central:13524 Welch RoadDallas, Texas 75244
Phone: 972-387-4500Fax: 972-387-4673Toll Free: 1-800-527-0890
East:1649 South Batesville RoadGreer, South Carolina 29650
Phone: 864-297-1382Fax: 864-234-7548Toll Free: 1-800-845-4455
West:210 Lyon DriveFernley, Nevada 89408
Phone: 775-575-4849 Fax: 775-575-5035 Toll Free: 1-800-762-9462
Improving Your Design.
Member of: