Upload
sureshbabu-thamburaj
View
102
Download
5
Embed Size (px)
DESCRIPTION
Turbine Manufacturer List
Citation preview
Turbine Directory Contents
Gas & Steam Turbine Directory
19www.PowerEngineeringInt.com Power Engineering International April 2014
Gas Turbine Technical Specifications 20
Steam Turbine Technical Specifications 28
Products 30Actuators 30Air cleaners, dryers and filters 30Air conditioning and refrigeration 30Air heaters and preheaters 30Air pollution monitors and CEMS 30Alignment and balancing equipment 30Bearings 30Borescopes, videoscopes, fiberscopes 30Burners and ignition systems 30Castings 30Coatings/lining materials 30Cogeneration systems 30Combined cycles 30Combustion 30
air flow measurement 30control and optimization systems 30pressure monitoring 30systems and burners 30
Compressors 30air 30gas 30
Computer-aided design and engineering 30
Condenser tubes 30Condensers 30Controllers 30
airflow 30energy management 30meters and instruments 30temperature monitoring 30
Control panels and consoles 30Control systems 30Corrosion prevention products 31Couplings 31Dampers 31Desuperheaters 31Detection systems, flame 31Diagnostic systems 31Drives 31
dampers 31electronic 31fluid 31mechanical 31variable speed 31other 31
Ducts 31Fans 31Filters and filtration systems 31Gas turbine inlet cooling 31Gas turbines 31Gas turbine parts, components and
accessories 32Gasification systems 32Gears 32Generators 32Heat exchangers 32Heat recovery systems/HRSGs 32Heaters 32Indicators 32
flow 32level 32pressure 32temperature 32
Inspection equipment 32Instruments, measuring 32Insulation 32Leak detection 32Lube-oil systems 32Lubricants 32Microturbines 32Monitoring equipment 32
combustion control 32continuous emission monitoring equipment 32emissions 32temperature 32general 32
Nitrogen oxide control systems 32Noise measurement and control 33Oil 33
cleaning systems 33conditioning equipment 33oil/water separators 33
Piping 33Pressure monitoring, measuring 33Pumps 33Reheaters 33Remote monitoring 33Safety equipment 33Seals 33Sensors 33Spray nozzles 33Steam generators 33Steam turbines 33Steam turbine parts, components and
accessories 34Superheaters 34Test equipment 34Torque conversion 34Turbomachinery controls 34Valve actuators 34Valves 34Vibration 34
analysis 34control 34monitoring 34
Wear resistant coatings and parts 34
Services 34Aftermarket parts and services 34Air compressors, overhaul
and repair 34Air pollution control services 34Alignment/balancing 34Bearings 34Calibration 34Cogeneration 34Combustion diagnostics and testing 34Condensers 34
cleaning 34repair 34retubing 34
Control system design and maintenance 34
Corrosion control and monitoring 34Fans 34
maintenance 34
rebuilding 34repair 34
Filter services and maintenance 34
Gas turbine inlet cooling 34design/engineering 34maintenance/repair 34
Gas turbines 34blade repair 34installation 34maintenance 34overhauling 35rebuilding 35servicing 35
Gear repair 35
Generators 35design 35maintenance 35rebuilding 35repair 35rewinding 35
Heat exchangers 35coil upgrading 35retubing 35tube cleaning 35tube plugging 35
Heat recovery/HRSGs 35
Inspection services 35
Instrumentation and control systems 35calibration 35maintenance 35
Life extension services 35
Lube oil 35
Maintenance services 35
Mechanical failure analysis 35
Metal fabricating and machining 35
Monitoring 35
Outage services 35
Pumps and compressors 35overhauling 35rebuilding 35repair 35
Repair services, general 35
Steam generators, maintenance
and repair 35
Steam generators, nuclear 35
Steam turbines 35aligning 35blade repair 35installation 35maintenance 35overhauling 35rebuilding 35
Valves 35reconditioning 35repairing 35testing 35
Vibration control 35balancing 35monitoring 35
1404PEI_19 19 4/8/14 10:24 AM
20 www.PowerEngineeringInt.com
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Manufacturer ModelGross output (MW)
Net output (CC) MW
Net output (SC) MW
Heat rate (kJ/kWh)
Gross effciency (%)
Net effciency (CC) (%)
Frequency (Hz)
Shaft speed (rpm)
Alstom
GT24 230.7 664 9000 40.0 58.4 60 3600
GT26 326 467 8933 40.3 59.5 50 3000
GT13E2 202.7 281 9474 38.0 53.5 50 3000
GT11N2 113.6 345 10,811 33.3 51.3 50 3610
GT11N2 115.4 349 10,619 33.9 51.8 60 3600
Ansaldo Energia
AE64.3A 75 111.7 73.5 10,028 35.90 53.75 50/60 3000/3600
AE94.2 185.3 277.4 181 9939 36.22 54.57 50 3000
AE94.2K 170 Case by case Case by case 9863 36.50 Case by case 50 3000
AE94.3A 310 456.4 304 9045 39.80 58.86 50 3000
Dresser -Rand
KG2-3G 2 14,100 25.5 50/60 25,500
KG2-3E 1.9 21,000 17.5 50/60 18,800
VECTRA
30G23.9 9553 37.7 50/60 6200
VECTRA
40G31.1 8963 40.2 50/60 6200
VECTRA
40G434.3 8916 40.4 50/60 6200
DR-61G 23.9 9588 37.5 50/60 3600
DR-61GP 31.4 9114 39.5 50/60 3600
DR-61G4 33.9 9104 39.5 50/60 3600
DR-
63GPC44.3 8449 42.6 50/60 3600
DR-
63GPG53.2 8346 43.1 50/60 3930
Manufacturer Model Year Net output (MW) Heat rate (Btu/kWh) Net heat rate (kJ/kWh) Net effciency (%) Pressure ratio
GE Energy (Heavy Duty,
Simple Cycle)
6B.03 1978 43.1 10,180 10,740 33.5 12.7
6F.03 2003 79.2 9470 9991 36.0 16.1
7E.03 1984 90 10,060 10,614 33.9 12.8
7F.04 2009 187 8850 9337 38.6 16.2
7F.05 2009 227 8680 9158 39.3 18.4
7HA.01 2012 275 8240 8694 41.4 21.5
7HA.02 2014 330 8240 8694 41.4 21.5
9E.03 1992 130 9860 10,403 34.6 12.9
9F.03 1996 265 9020 9517 37.8 16.7
9F.05 2003 299 8810 9295 38.7 18.3
9HA.01 2011 397 8220 8673 41.5 21.8
9HA.02 2014 470 8220 8673 41.5 21.8
1404PEI_20 20 4/8/14 10:24 AM
www.PowerEngineeringInt.com 21
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Pressure ratio
Exhaust mass fow (kg/s)
Exhaust temperature
(ºC)
NOx emissions (ppmv)
Start up time (mins)
Weight (tonnes)Dimensions
L x W x H (metres)
Comments
35.4:1 505 597 <25 230 10.7 x 4 x 4.6CC performance refers to KA24-2 MS
(2-on-1 Multishaft confguration CCPP); Dual fuel burner option available
35.0:1 692 603 <25 406 12 x 4.9 x 5.5CC performance refers to KA26-1 SS
(1-on-1 Single shaft confguration CCPP); Dual fuel burner option available
18.2:1 624 501 <25 350 11 x 5.4 x 5.5 CC performance refers to KA13E2-1 MS (1-
on-1 Multishaft confguration CCPP); Dual fuel burner option available
15.9:1 400 526 <25 190 13.1 x 5.5 x 10.1 CC performance refers to KA11N2-2 MS
(2-on-1 Multishaft confguration CCPP); incl. gear box, Dual fuel burner option available
15.9:1 400 526 <25 190 9.4 x 5.5 x 10.1
CC performance refers to KA11N2-2 MS (2-
on-1 Multishaft confguration CCPP);
Dual fuel burner option available
16.7 213 574 <25 Case by case 100 12 x 4 x 5
12.0 556 541 <25 Case by case 280 15 x 14 x 9
12.0 540 545 Case by case Case by case 280 15 x 14 x 9 Low BTU Fuels
19.5 750 576 <25 Case by case 360 14 x 7 x 9
7.1 9.5 583 <24 ppm 16 6.7 x 2.1 x 2.7
4.5 15.0 560 60 ppm 0.5 16 6.7 x 2.1 x 2.7
18.2 68.7 545SAC and DLE
available47 7 x 4.1 x 5.6
21.9 84.4 531SAC and DLE
available47 7 x 4.1 x 5.6
23.6 90.1 541SAC and DLE
available47 7 x 4.1 x 5.6
18.2 69.5 533SAC and DLE
available45 7 x 4.1 x 5.6
22.5 87.3 515SAC and DLE
available45 7 x 4.1 x 5.6
23.0 91.6 527SAC and DLE
available45 7 x 4.1 x 5.6
27.6 125.7 454SAC and DLE
available50 7 x 4.1 x 5.6
31.1 141.4 471SAC and DLE
available50 7 x 4.1 x 5.6
Exhaust fow (kg/s)
Frequency (Hz)Turbine speed
(rpm)
Exhaust temperature
(°C)
Approx. weight (tonnes)
Dimensions L x W x H (metres)
Comments
145 50/60 5163 539 222 24 x 4 x 4 Available in 50 Hz & 60 Hz
214 50/60 5231 592 254 23 x 4 x 5 Available in 50 Hz & 60 Hz
292 60 3600 546 300 20 x 4 x 4
450 60 3600 601 480 24 x 7 x 4
533 60 3600 606 530 24 x 7 x 4
576 60 3600 618 600 25 x 5 x 7
690 60 3600 618 660 27 x 5 x 6
416 50 3000 542 410 21 x 5 x 5
665 50 3000 595 641 28 x 5 x 5
667 50 3000 639 724 28 x 5 x 5
826 50 3000 619 950 30 x 6 x 6
978 50 3000 619 1,050 33 x 6 x 6
1404PEI_21 21 4/8/14 10:24 AM
22 www.PowerEngineeringInt.com
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Manufacturer Model YearGross plant output
(MW)Net plant output
(MW)Net plant effciency
(%)Net heat rate (kJ/kWh)
GE Energy (Heavy Duty,
Combined Cycle)
1x1 6B.03 1987 66 64.8 50.4 7141
2x1 6B.03 1979 133.1 130.9 50.9 7069
1x1 6F.03 1991 120.4 118.4 55 6540
2x1 6F.03 1991 243.1 239.4 55.6 6470
1x1 9E.03 1979 198.1 195 52.1 6911
2x1 9E.03 1979 398.4 392.5 52.7 6837
1x1 9F.03 1994 408 403 58.1 6194
2x1 9F.03 1994 822 811 58.5 6158
1x1 9F.05 2002 461 455 59.5 6055
2x1 9F.05 2002 926 914 59.7 6027
1x1 9HA.01 2011 600 592 61.4 5862
2x1 9HA.01 2011 1195 1181 61.2 5878
1x1 9HA.02 2014 710 701 61.4 5862
2x1 9HA.02 2014 1415 1398 61.2 5878
1x1 6B.03 1987 66 64.8 50.4 7141
2x1 6B.03 1979 133.1 130.9 50.9 7069
1x1 6F.03 1991 120.4 118.4 55 6540
2x1 6F.03 1991 243.1 239.4 55.6 6470
1x1 7E.03 1977 137.6 135.4 51.1 7048
2x1 7E.03 1979 276.8 272.6 51.4 7007
1x1 7F.04 2009 286 283 58.8 6120
2x1 7F.04 2009 574 567 59 6107
1x1 7F.05 2009 347 343 59.3 6068
2x1 7F.05 2009 697 688 59.5 6054
1x1 7HA.01 2012 410 405 61.1 5892
2x1 7HA.01 2012 823 813 61.2 5878
1x1 7HA.02 2014 492 486 61.1 5892
2x1 7HA.02 2014 987 976 61.2 5878
Manufacturer ModelGross output
(MW)Heat rate (kJ/kWh)
Gross effciency (%)
Frequency (Hz)
Shaft speed (rpm)
Kawasaki Heavy Industries
GPB300D 30.1 8977 40.1 50 Gas Generator Rotor 9330 / Power Turbine Rotor 5600
GPB180D 18.4 10,526 34.2 50 9420
GPB80D 7.8 10,714 33.6 50 13,800
GPB70D 6.7 12,000 30 50 13,800
GPB17D 1.7 13,382 26.9 50 21,965
GBP06 0.6 18,947 19.4 50 31,376
Manufacturer ModelGross output
(MW)Heat rate (kJ/kWh)
Gross effciency (%)
Frequency (Hz) Shaft speed (rpm)
MHPS (Simple Cycle)
H-15 17.03 10,409 34.6 50/60 9710
H-25(32) 32.3 10,341 34.8 50/60 7280
H-25(35) 37.69 10,292 35.0 50/60 7280
Manufacturer ModelGross output
(MW)Net output (CC) MW
Net output (SC) MW
Heat rate (kJ/kWh)
Gross effciency (%)
Net effciency (CC) (%)
Frequency (Hz)
Shaft speed (rpm)
MAN Diesel & Turbo
THM1304-10N 10.5 Case by case 10.08 11,840 30.4 Case by case 50/60 9000
THM1304-12N 12.5 Case by case 12.00 11,320 31.8 Case by case 50/60 9000
MGT6100 6.52 Case by case 6.52 11,250 32.0 Case by case 50/60 1500/1800
1404PEI_22 22 4/8/14 10:24 AM
www.PowerEngineeringInt.com 23
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Condenser pressure (inch Hg)
Frequency (Hz) Gas turbine power (MW) Steam turbine power (MW) No. & type of gas turbine
1.2 50 42.578 23.445 1 x 6B.03
1.2 50 85.156 47.977 2 x 6B.03
1.2 50 78.619 41.742 1 x 6F.03
1.2 50 157.237 85.883 2 x 6F.03
1.2 50 128.650 69.404 1 x 9E.03
1.2 50 257.301 141.073 2 x 9E.03
1.2 50 262.864 145.490 1 x 9F.03
1.2 50 525.728 295.792 2 x 9F.03
1.2 50 297.521 163.576 1 x 9F.05
1.2 50 595.038 330.697 2 x 9F.05
1.2 50 394.472 205.191 1 x 9HA.01
1.2 50 789.352 405.920 2 x 9HA.01
1.2 50 467.008 242.922 1 x 9HA.02
1.2 50 934.497 480.560 2 x 9HA.02
1.2 60 42.578 23.445 1 x 6B.03
1.2 60 85.156 47.977 2 x 6B.03
1.2 60 78.619 41.742 1 x 6F.03
1.2 60 157.237 85.883 2 x 6F.03
1.2 60 89.148 48.466 1 x 7E.03
1.2 60 178.296 98.490 2 x 7E.03
1.2 60 185.903 100.549 1 x 7F.04
1.2 60 371.805 202.666 2 x 7F.04
1.2 60 226.234 121.041 1 x 7F.05
1.2 60 452.468 244.346 2 x 7F.05
1.2 60 273.418 136.782 1 x 7HA.01
1.2 60 546.836 276.028 2 x 7HA.01
1.2 60 328.101 164.138 1 x 7HA.02
1.2 60 656.203 331.233 2 x 7HA.02
Pressure ratioTurbine inlet temperature
(ºC)
Exhaust mass fow (kg/s)
Exhaust temperature
(ºC)
NOx emissions (ppmv)
Start up time (mins)
Weight (tonnes)
Dimensions L x W x H (metres)
Comments
24.5 1270 87.2 470 15 15 250 22 x 7.1 x 13.8 Two shaft gas turbine
18.3 1250 59.8 542 15 15 190 18 x 4.9 x 9.8 Single shaft gas turbine
15.9 1160 27.3 523 15 6.6 75 14.5 x 3.5 x 8.1 Single shaft gas turbine
15.9 1160 27.0 513 25 6.6 75 14.5 x 3.5 x 8.2 Single shaft gas turbine
10.5 1035 8 521 9 60 seconds. 35 8.4 x 2.75 x 6.3 Single shaft gas turbine
8.5 <1035 5.05 474 36 60 seconds. 15 6.3 x 2.2 x 5.8 Single shaft gas turbine
Pressure ratio Exhaust mass fow (kg/s) Exhaust temperature (ºC) Weight (tonnes) Dimensions L x W x H (metres)
14.8 53.3 556 200 20 x 6 x 11
14.8 96.6 562 300 18 x 10 x 14
17.3 112.1 556 409 24 x 10 x 14
Pressure ratioTurbine inlet temperature
(ºC)
Exhaust mass fow (kg/s)
Exhaust temperature (ºC)NOx emissions
(ppmv)Weight (tonnes)
Dimensions L x W x H (metres)
Comments
10 46.5 490 <25 @ 70-100% load Case by case 77 16 x 3 x 5 incl. generator
11 49.1 515 <25 @ 70-100% load Case by case 77 16 x 4 x 6 incl. generator
28.0 465 <15 @ 50-100% load Case by case
1404PEI_23 23 4/8/14 10:24 AM
24 www.PowerEngineeringInt.com
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Manufacturer Model Gross output (MW) Heat rate (kJ/kWh)
MHPS (Combined Cycle)
1x1 H-25(32) 47.9 7080
1x1 H-25(32) 96.7 7013
1x1 H-25(35) 55.59 7071
2x1 H-25(35) 112.18 7007
1x1 H-25(42) 59.93 6889
2x1 H-25(42) 120.76 6825
1080 H-80 160.64 6660
2080 H-80 329.78 6494
1080 H-80 159.61 6691
2080 H-80 327.62 6519
MPCP1(M701) 214.49 7000
MPCP2(M701) 430.58 6974
MPCP3(M701) 650.97 6974
MPCP1(M701F4) 482.3 6000
MPCP2(M701F4) 967.6 5981
MPCP1(M701G) 506.3 6071
MPCP2(M701G) 1016 6051
MPCP1(M701F5) 530 5902
MPCP2(M701F5) 1063.3 5883
MPCP1(M701JAC) 675 < 5902
MPCP1(M701J) 687 5835
MPCP1(M501) 169.2 7000
MPCP2(M501) 339.9 6974
MPCP3(M501) 511.75 6974
MPCP1(M501F) 287.8 6305
MPCP2(M501F) 577.600 6283
MPCP1(M501G) 402.000 6165
MPCP2(M501G) 806.7 6144
MPCP1(M501GAC) 414.8 6051
MPCP2(M501GAC) 830.9 6041
MPCP1(M501JAC) 450 < 5902
MPCP1(M501J) 475 5854
MPCP2(M501J) 952.9 5835
Manufacturer ModelGross output
(MW)Heat rate (kJ/kWh)
Gross effciency (%)
Frequency (Hz) Shaft speed (rpm)
MHPS
(Simple Cycle)
H-25(42) 42.03 9667 37.2 50/60 7280
H-80 112.44 9421 38.2 50 3000
H-80 110.61 9585 37.6 60 3600
MF-61 5.925 12,566 28.7 50/60 13,800
MF-111 14.57 11,627 31 50/60 9660
MFT-8 26.78 9306 38.7 50/60 5000
MF-221 30 11,258 32 50/60 7200
M701DA 144.09 10,351 34.8 50 3000
M701F4 324.3 9028 39.9 50 3000
M701G2 334 9106 39.5 50 3000
M701F5 359 9000 40 50 3000
M701JAC 445 < 8784 > 41 50 3000
M701J 470 8784 41.0 50 3000
M501DA 113.95 10319 34.9 60 3600
M501F3 185.4 9739 37 60 3600
M501G1 267.5 9211 39.1 60 3600
M501GAC 276 9047 39.8 60 3600
M501JAC 310 < 8784 > 41 60 3600
M501J 327 8784 41 60 3600
1404PEI_24 24 4/8/14 10:24 AM
www.PowerEngineeringInt.com 25
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Frequency (Hz) Condensate Pressure (inch Hg) Gas turbine power (MW)
50/60 1.2 31.1
50/60 1.2 62.2
50/60 1.2 36.4
50/60 1.2 72.8
50/60 1.2 40.6
50/60 1.2 81.2
50 1.2 109.5
50 1.2 218.4
60 1.2 108
60 1.2 214.6
50 1.5 142.1
50 1.5 284.2
50 1.5 426.3
50 1.5 319.9
50 1.5 639.8
50 1.5 325.7
50 1.5 651.4
50 1.5 354
50 1.5 708
50 1.5 445
50 1.5 463
60 1.5 112.1
60 1.5 224.2
60 1.5 336.3
60 1.5 182.7
60 1.5 365.4
60 1.5 264.4
60 1.5 528.8
60 1.5 273.6
60 1.5 547.2
60 1.5 310
60 1.5 322
60 1.5 644
Pressure ratio Exhaust mass fow (kg/s) Exhaust temperature (ºC) Weight (tonnes)Dimensions
L x W x H (metres)
17.3 111 556 409 24 x 10 x 14
19.3 308 538 563 37 x 12 x 15
19.2 307 545 563 37 x 12 x 15
15 27 496 10 3.7 x 2.5 x 3.1
15 54 530 22 5.5 x 2.8 x 2.5
21 86 463 7 7.1 x 2.5 x 2.5
15 107 532 50 7.7 x 3.7 x 3.4
14 440 542 200 12.5 x 5.2 x 5.2
18 712 591 419 17.4 x 5.8 x 5.8
21 737 587 420 18.3 x 6.1 x 6.1
21 712 610 481 17.4 x 5.8 x 5.8
23 861 615
23 861 637 561 18.3 x 7.1 x 7.1
14 346 542 145 11.6 x 5.8 x 4.3
16 458 613 195 14.1 x 4.6 x 4.6
20 598 600 334 15.3 x 5.5 x 5.5
20 598 617 271 15.3 x 5.5 x 5.5
23 598 612 318 15.3 x 5.5 x 5.5
23 598 635 318 15.3 x 5.5 x 5.5
1404PEI_25 25 4/8/14 10:24 AM
26 www.PowerEngineeringInt.com
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Manufacturer ModelGross output
(MW)Net output (CC) MW
Net output (SC) MW
Heat rate (kJ/kWh)
Gross effciency
(%)
Net effciency (CC) (%)
Frequency (Hz)
Shaft speed (rpm)
Rolls-Royce
RB211-G62 DLE 37.7 26.7 12 7175 50.2 50/60 4800
RB211-GT62 DLE 39.7 28.6 12.2 7005 51.4 50/60 4800
RB211-GT61 DLE 42.6 31.1 12.59 6820 52.8 50/60 4850
Trent 60 DLE 65.3 50.7 15.82 6718 53.6 50 3000
Trent 60 DLE 78.3 50.7 29.3 6936 51.9 50 3000
Trent 60 DLE ISI 77.6 61.9 17.1 6736 53.4 50 3000
Trent 60 DLE ISI 94.1 61.9 34.2 6992 51.5 50 3000
Trent 60 WLE 81.2 64.4 18.2 6998 51.4 50 3000
Trent 60 WLE 107.2 64.4 45.3 7339 49 50 3000
Trent 60 WLE ISI 82.8 66 18.4 7022 51.2 50 3000
Trent 60 WLE ISI 109.5 66 46.2 7355 48.9 50 3000
Trent 60 DLE 66.4 51.6 16 6725 53.5 60 3600
Trent 60 DLE 79.6 51.6 29.7 6945 51.8 60 3600
Trent 60 DLE ISI 75.4 60.2 16.6 6727 53.5 60 3600
Trent 60 DLE ISI 90.8 60.2 32.6 6969 51.6 60 3600
Trent 60 WLE 77.9 61.7 17.6 6998 51.4 60 3600
Trent 60 WLE 102.4 61.7 43.1 7340 49 60 3600
Trent 60 WLE ISI 80.3 64 17.7 7093 50.7 60 3600
Trent 60 WLE ISI 105.7 64 44.2 7404 48.6 60 3600
Siemens AG Energy Sector
SGT-200 7.68 10,776 33.4 50/60
SGT-300 7.90 11,773 30.6 50/60
SGT-400 12.90 10,355 34.8 50/60
SGT-400 14.33 10,178 35.4 50/60
SGT-500 19.06 10,690 33.7 50/60
SGT-600 24.48 10,720 33.6 50/60
SGT-700 32.82 9675 37.2 50/60
SGT-750 37.03 9120 39.5 50/60
SGT-800 47.50 9557 37.7 50/60
SGT-800 50.50 9407 38.3 50/60
SGT5-2000E 172 10,190 35.3 50 3000
SGT5-4000F 307 9001 40 50 3000
SGT5-8000H 375 8999 40 50 3000
SGT6-2000E 114 10,496 34.3 60 3600
SGT6-5000F 232 9278 38.8 60 3600
SGT6-8000H 274 8999 40 60 3600
Manufacturer ModelGross output
(MW)Net output (CC) MW
Net output (SC) MW
Heat rate (kJ/kWh)
Gross effciency (%)
PW Power Systems
FT8® MOBILEPAC® 25.4 25.2 LHV Gross HR 10,370 kJ/kWh 34.9
FT8® SWIFTPAC® 30 41.1 30.1 LHV Plant Net HR 7333 kJ/kWh
FT8® SWIFTPAC® 60 83.1 60.5 LHV Plant Net HR 7257 kJ/kWh
FT4000™ SWIFTPAC® 60 83.9 67.6 LHV Plant Net HR 7250 kJ/kWh
FT4000™ SWIFTPAC® 120 169.0 136.2 LHV Plant Net HR 7193 kJ/kWh
1404PEI_26 26 4/8/14 10:24 AM
www.PowerEngineeringInt.com 27
Gas Turbine Technical Specifcations
Power Engineering International April 2014
Pressure ratioTurbine inlet temperature
(ºC)
Exhaust mass fow (kg/s)
Exhaust temperature
(ºC)
NOx emissions (ppmv)
Start up time (mins)
Weight (tonnes)
Dimensions L x W x H (metres)
Comments
20.35 90.4 25 18.5 x 4 x 5 2P unfred
21.39 94.1 25 18.5 x 4 x 5 2P unfred
21.29 92.4 25 18.5 x 4 x 5 2P unfred
33.81 152.2 25 26.52 x 4.57 x 18.9 2P unfred
33.81 152.2 25 26.52 x 4.57 x 18.9 2P fred to 1112°F (600°C)
38.73 174.1 25 29.56 x 4.57 x 18.9 2P ISI unfred
38.73 174.1 25 29.56 x 4.57 x 18.9 2P ISI fred to 1112°F (600°C)
38.9 176.3 25 26.52 x 4.57 x 18.9 2P unfred
38.9 176.3 25 26.52 x 4.57 x 18.9 1P fred to 1300°F (704°C)
39.43 178.9 25 29.56 x 4.57 x 18.9 2P ISI unfred
39.43 178.9 25 29.56 x 4.57 x 18.9 1P ISI fred to 1300°F (704°C)
34.1 153.3 25 26.52 x 4.57 x 18.9 2P unfred
34.1 153.3 25 26.52 x 4.57 x 18.9 2P fred to 1112°F (600°C)
37.99 166.2 25 29.56 x 4.57 x 18.9 2P ISI unfred
37.99 166.2 25 29.56 x 4.57 x 18.9 2P ISI fred to 1112°F (600°C)
36.87 167 25 26.52 x 4.57 x 18.9 2P unfred
36.87 167 25 26.52 x 4.57 x 18.9 1P fred to 1300°F (704°C)
37.81 178.1 25 29.56 x 4.57 x 18.9 2P ISI unfred
37.81 178.1 25 29.56 x 4.57 x 18.9 1P ISI fred to 1300°F (704°C)
12.3 29.5 493 ≤ 25
13.7 30.2 542 ≤ 15
16.8 39.4 555 ≤ 15
18.9 44.3 539 ≤ 15
13.0 97.9 369 ≤ 42 150,139 21.3 x 4 x 3.7
14.0 81.3 543. ≤ 25 122,924 19.2 x 4.6 x 4
18.7 95.0 533 ≤ 15 143,789 19.2 x 4.6 x 4
23.8 114.2 458.5 ≤ 15
20.4 132.8 541 ≤ 15 171,900 17 x 4.5 x 4
21.1 134.2 553 ≤ 15 171,900 17 x 4.5 x 4
12.1 531.0 537 216,000 14 x 12.5 x 8.5
18.8 723.0 579 312,000 11 x 4.9 x 4.9
19.2 829.0 627 390,000 13.1 x 4.9 x 4.9
12.1 367.0 537 163,000 11.6 x 10.4 x 7
18.9 551.0 593 193,000 10.1 x 4 x 4
19.5 604.0 617 286,000 11 x 4.3 x 4.3
Net effciency (CC) (%) Frequency (Hz)Shaft speed
(rpm)Pressure ratio
Exhaust mass fow (kg/s)
Exhaust temperature (ºC)
NOx emissions (ppmv)
50/60 19.9 88 469 25
Net Effciency LHV = 49.1 50/60 21.3 91 490 25
Net Effciency LHV = 49.6 50/60 21.3 182 490 25
Net Effciency LHV = 49.6 50/60 36.2 176 431 25
Net Effciency LHV = 50 50/60 36.2 351 431 25
1404PEI_27 27 4/8/14 10:24 AM
28 Power Engineering International April 2014 www.PowerEngineeringInt.com
Steam Turbine Technical Specifcations
OEM Model Type/ApplicationPower rating
(MW)
Shaft speed
(rpm)Dimensions LxWxH (metres)
Inlet temp.
(oC)
Inlet
pressure
(bar)
Gas fow rate
(m3/h)
Alstom
GRTCCPP/Biomass/Industrial applications/
Waste-to-Energy (WtE)/CSP/Conventional power plants/Geothermal
5–65 4200–11,000
3.6 x 14 (30 MW turbine + generator, typical)
4.7 x 20 (60 MW turbine + generator, typical)
540 125 n/a
MTCCPP/Biomass/Industrial applications/ WtE/CSP/Conventional power plants/
Geothermal50–100+ 3000–3600 Depending on confguration 565 140 n/a
COMAX Cogneration applications 100–400 3000–3600 Depending on confguration 565 140 n/a
STF15C Combined-cycle power plants 100–250 3000–3600 Depending on confguration 565/565 165/15 n/a
STF30C Combined-cycle power plants 150–400 3000–3600 Depending on confguration 585/585 185/45 n/a
STF25 Steam power plants 100–350 3000–3600 Depending on confguration 540/540 540/540 n/a
STF40 Steam power plants 250–700 3000–3600 Depending on confguration 600/620 300/65 n/a
STF60 Steam power plants 500–900 3000–3600 Depending on confguration 600/620 300/65 n/a
STF100 Steam power plants 700–1200 3000–3600 Depending on confguration 600/620 300/65 n/a
STN series Nuclear applications (full-speed) 100–800 3000–3600 Depending on confguration 250–290 42–75 Adaptable to any reactor
ARABELLE™ 1000
Nuclear applications (full-speed) 800–1300 1500–1800 Depending on confguration 250–290 42–75 Adaptable to any reactor
ARABELLE™
1700Nuclear applications (full-speed) 1300–1900 1500–1800 Depending on confguration 250–290 42–75
Adaptable to
any reactor
Ansaldo Energia
MT10 Combined cycle 40–250 50/60 Hz applicable 1-cylinder Non re-heat
MT20 Combined cycle 150–350 50/60 Hz applicable 2-cylinder Non re-heat
MT15 Combined cycle, Fossil, Solar 90–300 50/60 Hz applicable 2-cylinder Re-heat
RT30 Combined cycle, Fossil 150–400 50/60 Hz applicable 3 to 4 cylinder Re-heat
RT70 Fossil 400–1000 50/60 Hz applicable 4 to 5 cylinder Re-heat
GE Energy
A200 Combined cycle 70–220 3000 Up to 538 Up to 103 Up to 750
D200 Combined cycle 180–330 3000 Up to 538 Up to 103 Up to 1090
A450 Combined cycle 150–290 3000 Up to 600 Up to 131 Up to 750
D400 Combined cycle 230–440 3000 Up to 600 Up to 131 Up to 940
A650 Combined cycle 150–300 3000 Up to 600 Up to 166 Up to 750
D600 Combined cycle 230–550 3000 Up to 600 Up to 166 Up to 1090
D650 Combined cycle 230–550 3000 Up to 600 Up to 166 Up to 1090
A200 Combined cycle 50–200 3600 Up to 538 Up to 103 Up to 750
D200 Combined cycle 120–300 3600 Up to 538 Up to 103 Up to 1090
A450 Combined cycle 100–250 3600 Up to 600 Up to 131 Up to 750
D400 Combined cycle 180–400 3600 Up to 600 Up to 131 Up to 940
A650 Combined cycle 100–260 3600 Up to 600 Up to 166 Up to 750
D600 Combined cycle 180–500 3600 Up to 600 Up to 166 Up to 1090
D650 Combined cycle 180–500 3600 Up to 600 Up to 166 Up to 1090
MAN Diesel & Turbo
Standard Power generation 2–160 50/60 Hz 540 140
Low-pressure
turbinesPower generation 5–90 50/60 Hz
Saturated
steam1–20
Air turbines CAES (compressed air energy storage) 25–90 50/60 Hz 540 140
MARC 1Combined heat and power (CHP)generation
for Renewable energy and WtE 2–4 50 Hz 450 65
MARC 2 CHP generation for reneable energy and WtE 5–10 50 Hz 520 90
MARC 4 CHP generation for reneable energy and WtE 8–20 50 Hz 520 120
MARC 6 CHP generation for reneable energy and WtE 16–40 50 Hz 530 120
1404PEI_28 28 4/8/14 10:24 AM
www.PowerEngineeringInt.com 29Power Engineering International April 2014
Steam Turbine Technical Specifcations
OEM Model Type/ApplicationPower rating
(MW)
Shaft speed
(rpm)Dimensions LxWxH (metres)
Inlet
temp.
(oC)
Inlet pressure
(bar)
Gas
fow rate
(m3/h)
Power Machines
OJSC
ITT-30/40-2,9Condensing turbine with steam reheat for
industrial purposes and district heating/TPP30/40 3000 9.8 x 5.3 x 4.3 410 2.9 220
ITT-65/75-130/13Condensing turbine with steam reheat for
industrial purposes and district heating/TPP65/75 3000 14.3 x 5.3 x 4.2 555 12.8 400
P-50/60-130 Backpresure turbine / TPP 50/60 3000 8.9 x 3.6 x 4.6 555 12.8 490
ITT-90/100-
130/13-1M
Condensing turbine with steam reheat for
industrial purposes and district heating/TPP91 3000 14.8 x 6.5 x 4 555 12.8 470
P-85-8,8/0,2 Backpresure turbine /TPP 85 3000 9.5 x 3.6 x 2.43 535 8.8 450
KT-115-8,8Condensing turbine with steam extraction for
district heating / TPP115 3000 14.4 x 5.6 x 2.9 500 8.8 446
K-210-130-8 Condensing turbine /TPP 210 3000 19 x 6.5 x 5.5 540 12.8 640
K-255-162-2 Condensing turbine /TPP 255 3000 22.7x 11.4 x 6.8 540 15.9 700
K-165-130 Condensing turbine /TPP 165 3000 14.6 x 7.6 x 5.8 540 12.8 480
K-225-12,8-3 Condensing turbine /TPP 225 3000 20 x 8.5 x 5.7 540 12.8 540
K-168-107 Condensing turbine /TPP 167 3000 17.1 x 8.5 x 5.7 525 10.5 442
K-110-6,5 Condensing turbine / CCP 110/114 3000 16.4 x 8.5 x 5.7 497 6.5 309.3
T-110-140 Condensing turbine/TPP 110/123 3000 17.2 x 5 x 5.2 535 13.7 326
T-120-12,8 Condensing turbine /TPP 120 3000 14.9 x 5.9 x 5.1 565 12.8 470
T-125/150-7,4 Condensing turbine / CCP 125 3000 16.6 x 8.5 x 5.7 500 7.4 525
T-130/160-12,8 Condensing turbine /TPP 130/160 3000 15.3 x 8.5 x 5.5 555 12.8 500
T-150-7,7 Extraction turbine / CCP 150/160 3000 17 x 8.5 x 5.7 510 7.7 309.3
T-185/210-16,0-P Extraction turbine / TPP 186/210 3000 23.6 x 9.6 x 6.1 558 16 576
K-300-170-1P Condensing turbine /NPP 300/310 3000 24.7 x 11.4 x 6.9 540 16.7 960
K-330-23,5 Condensing turbine /TPP 330 3000 21.2 x 8.9 x 6.1 540 23.5 1050
K-800-130/3000 Condensing turbine /TPP 885 3000 41.6 x 11.4 x 6.9 485 12.8 3180
K-660-247 Condensing turbine /TPP 660/686 3000 36.5 x 9.8 x 6 537 24.3 2023.8
K1000-60/300 Condensing turbine /NPP 1030 3000 51.8 x 11.4 x 6.9 274.3 5.88 5870
K-1000-60/3000-2 Condensing turbine /NPP 995 3000 41.8 x 11.4 x 6.9 274.3 5.88 5980
K-1000-60/3000-3 Condensing turbine /NPP 1014 3000 33.8 x 16.3 x 7.8 274.3 5.88 5980
K -1200-6,8/50 Condensing turbine /NPP 1200 3000 53 x 11.4 x 6.9 505 6.8 4793
Siemens AG Energy Sector
SST-040 Up to 0.3 2.5 x 1.5 x 2 Up to 400 Up to 40Up to
15,000
SST-050 Up to 0.750 1 x 1 x 1.3
SST-060 Up to 6 1.5 x 2.5 x 2.5 Up to 131
SST-100 Up to 8.5 Up to 7500 8 x 3.7 x 3.4 Up to 480 Up to 65
SST-110 Up to 7 6 x 2.8 x 3.2 Up to 131
SST-111 Up to 12 9 x 4 x 4 Up to 530 Up to 131
SST-150 Up to 20 Up to 13300 12 x 4 x 5 Up to 505 Up to 103
SST-200 Up to 10 4 x 2 x 2.5 Up to 520 Up to 110
SST-300 Up to 50 Up to 12000 12 x 4 x 5 Up to 520 Up to 120
SST-400 Up to 65 3000–8000 18 x 8.5 x 5.5 Up to 540 Up to 140
SST-500 Up to 100 Up to 15000 19 x 6 x 5 Up to 400 Up to 30
SST-600 Up to 150 3000–18,000 19 x 6 x 5 Up to 565 Up to 165
SST-700 Up to 175 3000–13,200 22 x 15 x 6 Up to 585 Up to 165
SST-800 Up to 250 3000–3600 20 x 8.5 x 6 Up to 565 Up to 170
SST-900 Up to 250 3000–3600 20 x 11 x 10 Up to 585 Up to 165
SST-6000 300–1200 Up to 600 Up to 300
SST-5000 120–750 Up to 600 Up to 190
SST-3000 90–250 Up to 565 Up to 177
Doosan Skoda
SKODA MTD20 Single-casing/Fossil, CCPP, Renewables Up to 358000, 50/60 Hz
applicableUp to 540 Up to 140
SKODA MTD25 Single-casing/Fossil, CCPP, Renewables Up to 456500, 50/60 Hz
applicableUp to 540 Up to 140
SKODA MTD30 Single-casing/Fossil, CCPP, Renewables Up to 605500, 50/60 Hz
applicableUp to 540 Up to 140
SKODA MTD40 Single-casing/Fossil, CCPP, Renewables Up to 2003000/3600, 50/60 Hz
applicableUp to 580 Up to 165
1404PEI_29 29 4/8/14 10:24 AM