7360 86 90 1927 100 EQ EQ EQ EQ EQ 3350 1250 3690 13770 1800 9 1 0 9 0 1 9 4 0 270 90 1000 90 2930 90 2800 230 4150 230 7500 90 3470 90 3620 230 7360 1895 90 400 90 230 2000 90 910 90 2940 230 6490 90 2000 90 2940 230 4690 230 10270 1000 3550 230 3780 1000 2543 450 2318 450 3013 225 230 2650 90 2030 230 2780 90 5000 3100 600 8 3 0 90 1000 2500 2270 230 800 900 800 3690 90 3370 1060 2400 230 230 230 1000 180 1090 2540 230 5550 230 5030 230 2540 13720 3500 1460 6260 2500 230 3270 230 1000 230 6030 230 7500 1500 1500 4940 shower shower 95 270 95 270 94 616 654 487 94 783 MH TO MUNICIPAL CONNECTION TO MUNICIPAL CONNECTION MH whb whb RE 3 sss G RE 2 sss G shower WC whb bath WC whb DRAINAGE SECTION scale 1 : 100 DISTANCE COVER LEVEL INVERT LEVEL DEPTH FALL 450 RE 1 VENTILATE HEAD OF DRAINAGE RUN MIN. FALL 1 : 60 94 810 460 shower WC whb bath WC whb ±11,48m FALL DEPTH INVERT LEVEL COVER LEVEL DISTANCE 94 820 450 95 270 wm sss ±0,85m 95 270 ±1,93m WC MERANTI TIMBER & STEEL PERGOLA POST 152 x 50mm PAR MERANTI MEMBERS @ MAX, 600mm C/C 8 000mm WALLPLATE HEIGHT RESTICTION BOUNDARY LINE BOUNDARY LINE 1000mm HIGH BALUSTRADE TO COMPLY WITH MUNICIPAL AND NBR REGULATIONS. NO GAP OR OPENING SHALL BE ABLE TO LET THROUGH A BALL OF NOT LESS THAN 100mmø, AT ANY GIVEN POSITION OR POINT. 228 x 50mm PAR HARDWOOD BEARER FIBRE CEMENT CLADDING ROOF: PITCH 25 DEGREE 0,47mm ALUMINIUM-ZINK "SAFINTRA - CLASSICORR" CORRUGATED PROFILE ROOF SHEETING. FIBRE CEMENT PANEL scale 1 : 100 SOUTH WEST ELEVATION NOTES "S" = SAFETY GLASS "O" = OPAQUE GLASS ALL GLASS AREAS LARGER THAN 1m² OR LESS THAN 500mm FROM FLOOR LEVEL TO RECIEVE SAFETY GLAZING IN ACCORDANCE WITH SANS 10400-N:2011. GLASS THICKNESS: AS PER SANS 10400-N:2011, 4.2, TABLE 1 DOORS & WINDOWS: 6mm TOUGHENED SAFETY GLASS 1. THE CONTRACTOR MUST ESTABLISH THE POSITIONS OF BOUNDARY PEGS,EXISTING STRUCTURES & OBSTRUCTIONS BEFORE ANY WORK COMMENCES. 2. ANY EXCAVATION FOR ANY FOUNDATION MUST BE DONE UNTIL STABLE NATURAL GROUND IS REACHED AND NOT IN FILLED GROUND. 3. WHERE A FOUNDATION WALL IS HIGHER THAN 1 500mm A RETAINING WALL ACCORDING TO ENGINEERS SPECIFICATION MUST BE CONSTRUCTED. 4. FLOORSLABS TO BE CAST A MINIMUM OF 170mm (2 BRICK COURSES) ABOVE NATURAL GROUND LEVEL. 5. PREFABRICATED CONCRETE LINTOLS TO BE BUILT IN OVER ALL OPENINGS.LINTOLS MUST HAVE BEARING DISTANCE OF MINIMUM 225mm AT BOTH SIDES. 6. ALL WALLS TO HAVE "Brick-Force" AT EVERY 5TH COURSE.CAVITY WALLS TO HAVE MINIMUM OF 5 X WIRE TIES PER SQ/M. 7. "Brick-Force" FOR MINIMUM 4 BRICK COURSES ABOVE LINTOL HEIGHT. 8. ALL CARE MUST BE TAKEN TO KEEP CAVITIES CLEAN FROM DPC LEVEL TO EAVES LEVEL. 9. BEAM FILLING TO UNDERSIDE OF ROOF COVER. 10. ROOF OVERHANG : 300mm 11. ANY PERCEIVED INDISTINCTNESS OR CONTRADICTION IN THE DOCUMENTS MUST IMMIDIATELY BE CLEARED WITH THE ARCHITECT. 12. ALL GUTTERS AND DOWNPIPES TO BE ALLUMINIUM AND TO BE INSTALLED AS MANUFACTURER'S SPECIFICATION. NOTES RIDER PLAN FOR MSP DEVELOPMENTS KRAAIFONTEIN L201695 drw no. drawn rev. date job no. AS SHOWN @ A1 scale drawing title LRB project revision/issue no. date architect CONTRACTOR WD-01 Old Castle Brewery Unit 005 6 Beach Road Woodstock 7925 Email. [email protected] Tel. 021 447 1125 Fax. 021 447 7347 Cell. 082 823 1449 IN ASSOCIATION WITH WILHELM MARTIN BASSON ARCHITECTS cc.WORCESTER H. LE ROUX BASSON NDIP ARCH(CAPE TECH) B.BUILD(UPE) B.ARCH(UPE) SACAP REG. NO. 6 135 ALL WORK TO BE DONE IN ACCORDANCE WITH THE NATIONAL BUILDING REGULATIONS (SOUTH AFRICAN CODE OF PRACTICE) AND BUILDING STANDARDS ACT, ACT SABS 10400:2010 ALL SPECIFICATIONS ETC. TO BE IN ACCORDANCE WITH MODEL PREAMBLES FOR TRADES AS PUBLISHED BY THE ASSOCIATION OF SOUTH-AFRICAN QUANTITY SURVEYORS. ALL MATERIALS ETC. TO BE FITTED IN STRICT ACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS. CONTRACTOR TO ALLOW FOR ARCHITECTS BOARD ALL ELECTRICAL WIRES IN WALLS, FLOORS AND CONCRETE CEILINGS TO RUN IN SABS APPROVED CONDUITS REGULATIONS AND REQUIREMENTS OF ALL RELEVANT AUTHORITIES TO BE ADHERED TO. CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELS ON SITE BEFORE COMMENCING WITH WORK. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED MEASUREMENTS. ALL STRUCTURAL DESIGN TO BE THE RESPONSIBILITY OF A PROFESSIONAL ENGINEER. COPYRIGHT RESERVED. GENERAL NOTES C/L C/L C/L C/L C/L 152mm x 152mm x 6mm HOT DIPPED GALVANIZED MILD STEEL BASEPLATE, FIXED TO CONCRETE WITH 4 x M12 BOLTS TYPICAL PERGOLA FRONT ELEVATION scale 1 : 50 50mm x 152mm GALVANIZED STEEL SQUARE TUBING WELDED TO 152 x 152 x 6mm BASEPLATE 50mm X 152mm PAR HARDWOOD TIMBER MEMBER 50mm x 152mm GALVANIZED STEEL SQUARE TUBE SPACER C/L A A BOUNDARY WALL DETAIL scale 1 : 50 200 x 600 MASS CONCRETE STRIP FOUNDATION s c a l e 1 : 1 0 0 GROUND STOREY PLAN/SITE PLAN DRAINAGE NOTES ALL DRAINAGE TO BE IN ACCORDANCE WITH MUNICIPAL REGULATIONS. ALL UNDERGROUND PIPES TO BE 110mm DIAMETER P.V.C. PIPES. ANY DRAINAGE PIPE THAT RUNS BENEATH A CONCRETE SLAB TO BE ENCASED IN 100mm CLEAN SAND SURROUND.ALL VENT PIPES & WASTE PIPES TO BE 50mm DIAMETER. MOVEMENT JOINT NOTES: CONTRACTOR TO ALLOW FOR MOVEMENT JOINTS IN FLOOR SLABS & WALLS WHERE DEAMED NECESSARY.JOINTS TO BE SEALED WITH "JOINTEX" HOT WATER SERVICES NOTES: -A MIN. OF 50% OF WATER HEATING REQUIREMENTS TO BE PROVIDED BY RENEWABLE MEANS. -SOLAR WATER HEATING SYSTEM SHALL COMPLY WITH SANS 1307 & SANS 10106 -THERMAL PERFORMANCE TO BE DETERMINED IN ACCORDANCE WITH SANS 6211-1 & SANS 6211-2. -SOLAR WATER HEATING SYSTEM INSTALLATION TO COMPLY WITH SANS 10254 -HOT WATER CYLINDER TO RECEIVE 50mm THICK, NON-COMBUSTIBLE, LIGHTWEIGHT GLASSWOOL "ISOVER - GEYSER BLANKET". SEAL EDGES WITH DUCT TAPE. APPLY 2m OF 20mm THICK "SNAP-ON PIPE" INSULATION ON THE INCOMING COLD WATER PIPES. -ALL EXPOSED PIPES TO & FROM HOT WATER CYLINDER TO BE INSULATED WITH RIGID NON- COMBUSTIBLE LIGHTWEIGHT "ISOVER - GEYSER PIPE INSULATION" GLASSWOOL INSULATION WITH A WALL THICKNESS OF 35mm. INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DETAIL AND SPECIFICATIONS. REFER TO "ANNEXURE A" FOR FENESTRATION CALCULATIONS FENESTRATION NOTES: 1800mm HIGH PRECAST CONCRETE WALL 1000mm HIGH BALUSTRADE TO COMPLY WITH MUNICIPAL AND NBR REGULATIONS. NO GAP OR OPENING SHALL BE ABLE TO LET THROUGH A BALL OF NOT LESS THAN 100mmø, AT ANY GIVEN POSITION OR POINT. ERF 858 ERF 857 UNIT 28 UNIT 29 1800mm HIGH, 190mm THICK CONCRETE BLOCKWORK WALL 200 x 600 MASS CONCRETE STRIP FOUNDATION s c a l e 1 : 1 0 0 F I R S T S T O R E Y P L A N PALISADE FENCE 300mm HIGH, 190mm THICK CONCRETE BLOCKWORK WALL PALISADE FENCE 85mm PLASTER BAND CONCRETE BLOCKWORK, SMOOTH PLASTERED & PAINTED ON BOTH SIDES. PLASCON PAINT FINISH IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. FFL: 98 120 geyser trap door 20 000mm BOUNDARY LINE 20 000mm BOUNDARY LINE 9 000mm BOUNDARY L INE 9 000mm BOUNDARY L INE FIRE WALL TO U/S OF ROOF COVERING W12 FFL: 98 245 W8 W7 D3 D2 W11 W10 W9 EN-SUITE bic bic bic shwr shwr bath wc wc whb whb 14 13 12 11 10 9 8 7 6 5 4 3 2 1 B B BEDROOM 2 carpet carpet BEDROOM 3 tiles BATHR carpet MAIN BEDROOM BALCONY tiles PLATFFORM LEVEL 95 270 15mm PLASTER DETAIL TO ARCHITECT'S SPECIFICATION CHIMNEY TO COMPLY WITH ALL RULES & REGULATIONS AS PER IN SANS 10400-V:2010 4.3 ROOF TIMBERS TO STOP A MIN. OF 200mm AWAY FROM INSIDE WALL OF CHIMNEY. 1800mm HIGH, 140mm THICK CONCRETE BLOCKWORK WALL ADJACENT UNIT BOUNDARY LINE CENTRE LINE 200 x 600 MASS CONCRETE STRIP FOUNDATION 8 000mm WALLPLATE HEIGHT RESTICTION scale 1 : 100 SOUTH EAST ELEVATION ROOF: PITCH 1 DEGREE "KLIPLOK" ROOF SHEETING FIBRE CEMENT CLADDING EVACUATED TUBE COLLECTOR ACCORDING TO SPECIALISTS SPECIFICATIONS 15mm PLASTER DETAIL TO ARCHITECT'S SPECIFICATION BRICK WORK. SMOOTH PLASTERED & PAINTED PLASCON PAINT FINISH ACCORDING TO MANUFACTURERS SPECIFICATION OR APPROVED SIMILAR. COLOUR TO ARCHITECT'S SPECIFICATIONS. ADJACENT UNIT 1000mm HIGH BALUSTRADE TO COMPLY WITH MUNICIPAL AND NBR REGULATIONS. NO GAP OR OPENING SHALL BE ABLE TO LET THROUGH A BALL OF NOT LESS THAN 100mmø, AT ANY GIVEN POSITION OR POINT. scale 1 : 100 NORTH WEST ELEVATION BOUNDARY LINE CENTRE LINE 8 000mm WALLPLATE HEIGHT RESTICTION 1800mm HIGH, 450 X 450mm CONCRETE BLOCKWORK PIERS WITH PALISADE PANELS @ MAX 3500mm C/C. SMOOTH PLASTER & PAINT FINISH. PLASCON PAINT FINISH OR APPROVED SIMILAR. hwb re 4 paving braai re 1 re 2 re 3 ERF 858 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ZANDVLIET DRIVE STERLING GROVE CRESCENT ADJACENT ERF 857 wc STAIRS: RISERS: 194mm TREADS: 250mm W6 W5 W4 W3 W2 W1 CLASS E FIRE DOOR (30min) TO SANS 1253 FIRE WALL TO U/S OF SLAB PC REIN FORCED CONCR ETE LINTOL S OVER 2400 x 2 100mm SECTIO NAL OVERH EAD GARAG E DOOR 20 000mm BOUNDARY LINE 20 000mm BOUNDARY LINE 3100mm CWC 9 000mm BOUNDARY L INE 9 000mm BOUNDARY L INE f/fr wm FFL: 95 350 FFL: 95 525 stove sink D1 B B DRIVE WAY paving CARPORT paving tiles LOUNGE tiles granolithic screed GARAGE tiles GUEST WC tiles DINING KITCHEN tiles 2 2 145,11m 0,767 103,28m 57,38% 9,22m² 55,99m² 69,78m² FOYER tiles A A TO MUNICIPAL CONNECTION ADJACENT BUILDING LINES (BACK) 5 000mm 1 MAX. FLOOR FACTOR N/A MAX. FLOOR SPACE N/A BUILDING LINES (STREET) MAX. HEIGHT (ROOF) 8 000mm MAX. HEIGHT (WALLPLATE) 10 000mm BUILDING LINES (COMMON) ERF AREA THE SITE AREAS SCHEDULE: TYPE A SERVITUDES ZONING N/A GR1 180m² N/A COUNCIL DRAWINGS: GROUND STOREY PLAN/ SITE PLAN, FIRST STOREY PLAN, ELEVATION, DRAINAGE SECTION, PERGOLA ELEVATION, BOUNDARY WALL DETAIL ROOF: PITCH 1 DEGREE "KLIPLOK" ROOF SHEETING ON 50 x 152mm PAR HARDWOOD PURLIN ON 50 x 228mm PAR HARDWOOD BEAM FIXED TO TIMBER AND STEEL POST. D10 D9 D8 D7 D6 D5 D4 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING DEMILOSHED NEW BUILDING WORK EXISTING WORK LEGEND 16,22m² 9,22m² 3,12m² existing 3,12m² FLOOR FACTOR FOOTPRINT proposed COVERAGE THE BUILDING: TYPE B DESCRIPTION TOTAL BALCONY 154,33m² TOTAL GROUND STOREY FIRST STOREY 69,78m² 55,99m² CARPORT 9,22m² 16,22m² FFL: 95 525 "S" "S" W14 NEW COVERED PATIO COVERED PATIO FEB 2018 TYPE A

TYPE A - buhreinestate.co.zabuhreinestate.co.za/download/townhouses/sterling-grove/sterling... · 7500 1500 1500 4940 shower 95 270 95 270 94 616 487 654 94 783 mh to municipal connection

  • Upload
    haquynh

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

7360

86

90

19

27

10

0

EQEQEQEQEQ

3350

1250369013770

18

00

910

90

1940

27090 1

00

0 90

293

0

90

280

02

30

415

02

30

750

0

90

347

09

03

62

02

30

7360

1895

90

400

90

230

2000

90

910

90

2940

230

6490

902000902940230 4690 230

10270 1000

3550 230

3780 1000

254

34

50

231

84

50

301

32

25

230

265

0

90

203

0

230

278

0

90

500

03

10

0

600

830

90

100

0

2500

2270230

800900800

36

90

90

33

70

10

60

24

00

23

0

23

0

230

1000

180

1090

2540230

5550

230

5030

230

2540

13720

3500146062602500

230

3270

230

1000

230

6030

230

75

00

15

00

15

00

4940

showershower

95 27095 270

94 616

654487

94 783

MH

TO MUNICIPALCONNECTIONTO MUNICIPALCONNECTION

MH

whbwhb

RE 3

sss

G

RE 2

sss

G

shower

WCwhb

bath

WCwhb

DRAINAGE SECTIONscale 1 : 100

DISTANCE

COVER LEVEL

INVERT LEVEL

DEPTH

FALL

450

RE 1

VENTILATE HEAD OFDRAINAGE RUN

MIN. FALL 1 : 60

94 810

460

shower

WCwhb

bath

WCwhb

±11,48m

FALL

DEPTH

INVERT LEVEL

COVER LEVEL

DISTANCE

94 820

450

95 270

wmsss

±0,85m

95 270

±1,93m

WC

MERANTITIMBER & STEELPERGOLA POST

152 x 50mm PARMERANTI MEMBERS@ MAX, 600mm C/C

8 000mm WALLPLATE HEIGHT RESTICTION

BO

UN

DA

RY

LIN

E

BO

UN

DA

RY

LIN

E

1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPALAND NBR REGULATIONS. NOGAP OR OPENING SHALL BE

ABLE TO LET THROUGH ABALL OF NOT LESS THAN

100mmø, AT ANY GIVENPOSITION OR POINT.

228 x 50mm PARHARDWOOD BEARER

FIBRE CEMENTCLADDING

ROOF:PITCH 25 DEGREE

0,47mm ALUMINIUM-ZINK "SAFINTRA - CLASSICORR" CORRUGATED PROFILE ROOF SHEETING.

FIBRE CEMENTPANEL

scale 1 : 100

SOUTH WEST ELEVATION

NOTES

"S" = SAFETY GLASS"O" = OPAQUE GLASS

ALL GLASS AREASLARGER THAN 1m²OR LESS THAN 500mmFROM FLOOR LEVELTO RECIEVE SAFETYGLAZING INACCORDANCE WITHSANS 10400-N:2011.

GLASS THICKNESS:AS PER SANS10400-N:2011,4.2, TABLE 1

DOORS & WINDOWS:6mm TOUGHENEDSAFETY GLASS

1. THE CONTRACTOR MUST ESTABLISH THE POSITIONS OF BOUNDARY PEGS,EXISTING STRUCTURES & OBSTRUCTIONS BEFORE ANY WORK COMMENCES. 2. ANY EXCAVATION FOR ANY FOUNDATION MUST BE DONE UNTIL STABLE NATURAL GROUND IS REACHED AND NOT IN FILLED GROUND. 3. WHERE A FOUNDATION WALL IS HIGHER THAN 1 500mm A RETAINING WALL ACCORDING TO ENGINEERS SPECIFICATION MUST BE CONSTRUCTED. 4. FLOORSLABS TO BE CAST A MINIMUM OF 170mm (2 BRICK COURSES) ABOVE NATURAL GROUND LEVEL. 5. PREFABRICATED CONCRETE LINTOLS TO BE BUILT IN OVER ALL OPENINGS.LINTOLS MUST HAVE BEARING DISTANCE OF MINIMUM 225mm AT BOTH SIDES.

6. ALL WALLS TO HAVE "Brick-Force" AT EVERY 5TH COURSE.CAVITY WALLS TO HAVE MINIMUM OF 5 X WIRE TIES PER SQ/M. 7. "Brick-Force" FOR MINIMUM 4 BRICK COURSES ABOVE LINTOL HEIGHT. 8. ALL CARE MUST BE TAKEN TO KEEP CAVITIES CLEAN FROM DPC LEVEL TO EAVES LEVEL. 9. BEAM FILLING TO UNDERSIDE OF ROOF COVER. 10. ROOF OVERHANG : 300mm 11. ANY PERCEIVED INDISTINCTNESS OR CONTRADICTION IN THE DOCUMENTS MUST IMMIDIATELY BE CLEARED WITH THE ARCHITECT.

12. ALL GUTTERS AND DOWNPIPES TO BE ALLUMINIUMAND TO BE INSTALLED AS MANUFACTURER'S SPECIFICATION.

NOTES

RIDER PLAN FOR MSP DEVELOPMENTS

KRAAIFONTEIN

L201695

drw no.

drawn

rev.

date

job no.

AS SHOWN@ A1

scale

drawing title

LRB

project

revision/issueno. date

architect

CONTRACTOR

WD-01

Old Castle Brewery Unit 005 6 Beach Road Woodstock 7925

Email. [email protected]. 021 447 1125Fax. 021 447 7347Cell. 082 823 1449

IN ASSOCIATION WITH WILHELM MARTIN BASSON ARCHITECTS cc.WORCESTER

H. LE ROUX BASSONNDIP ARCH(CAPE TECH)

B.BUILD(UPE) B.ARCH(UPE)SACAP REG. NO. 6 135

ALL WORK TO BE DONE IN ACCORDANCE WITH THENATIONAL BUILDING REGULATIONS (SOUTH AFRICANCODE OF PRACTICE) AND BUILDING STANDARDS ACT,ACT SABS 10400:2010

ALL SPECIFICATIONS ETC. TO BE IN ACCORDANCEWITH MODEL PREAMBLES FOR TRADES AS PUBLISHEDBY THE ASSOCIATION OF SOUTH-AFRICAN QUANTITYSURVEYORS.

ALL MATERIALS ETC. TO BE FITTED IN STRICTACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS.

CONTRACTOR TO ALLOW FOR ARCHITECTS BOARD ALL ELECTRICAL WIRES IN WALLS, FLOORS ANDCONCRETE CEILINGS TO RUN IN SABS APPROVED CONDUITS

REGULATIONS AND REQUIREMENTS OF ALL RELEVANTAUTHORITIES TO BE ADHERED TO.CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELSON SITE BEFORE COMMENCING WITH WORK.FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TOSCALED MEASUREMENTS.ALL STRUCTURAL DESIGN TO BE THE RESPONSIBILITYOF A PROFESSIONAL ENGINEER.COPYRIGHT RESERVED.

GENERAL NOTES

C/L C/L C/L C/L C/L

152mm x 152mm x 6mm HOT DIPPED

GALVANIZED MILD STEEL BASEPLATE,

FIXED TO CONCRETE WITH 4 x M12 BOLTS

TYPICAL PERGOLA FRONT ELEVATIONscale 1 : 50

50mm x 152mmGALVANIZED

STEEL SQUARE TUBING WELDED

TO 152 x 152 x6mm BASEPLATE

50mm X 152mm PAR HARDWOODTIMBER MEMBER

50mm x 152mm GALVANIZED

STEEL SQUARE TUBE SPACER

C/L

A

A

BOUNDARY WALL DETAILscale 1 : 50

200 x 600MASS CONCRETE

STRIP FOUNDATION

scale 1 : 100

GROUND STOREY PLAN/SITE PLAN

DRAINAGE NOTES

ALL DRAINAGE TO BE IN ACCORDANCEWITH MUNICIPAL REGULATIONS.ALL UNDERGROUND PIPES TO BE 110mmDIAMETER P.V.C. PIPES.ANY DRAINAGE PIPE THAT RUNSBENEATH A CONCRETE SLAB TO BEENCASED IN 100mm CLEAN SANDSURROUND.ALL VENT PIPES & WASTEPIPES TO BE 50mm DIAMETER.

MOVEMENT JOINT NOTES:

CONTRACTOR TO ALLOW FOR MOVEMENT JOINTSIN FLOOR SLABS & WALLS WHERE DEAMEDNECESSARY.JOINTS TO BE SEALED WITH"JOINTEX"

HOT WATERSERVICES NOTES:

-A MIN. OF 50% OF WATER HEATING REQUIREMENTS TO BE PROVIDED BY RENEWABLE MEANS.-SOLAR WATER HEATING SYSTEM SHALL COMPLY WITH SANS 1307 & SANS 10106-THERMAL PERFORMANCE TO BE DETERMINED IN ACCORDANCE WITH SANS 6211-1 & SANS 6211-2.-SOLAR WATER HEATING SYSTEM INSTALLATION TO COMPLY WITH SANS 10254-HOT WATER CYLINDER TO RECEIVE 50mm THICK, NON-COMBUSTIBLE, LIGHTWEIGHT GLASSWOOL "ISOVER - GEYSER BLANKET". SEAL EDGES WITH DUCT TAPE. APPLY 2m OF 20mm THICK "SNAP-ON PIPE" INSULATION ON THE INCOMING COLD WATER PIPES.-ALL EXPOSED PIPES TO & FROM HOT WATER CYLINDER TO BE INSULATED WITH RIGID NON- COMBUSTIBLE LIGHTWEIGHT "ISOVER - GEYSER PIPE INSULATION" GLASSWOOL INSULATION WITH A WALL THICKNESS OF 35mm. INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DETAIL AND SPECIFICATIONS.

REFER TO "ANNEXUREA" FOR FENESTRATIONCALCULATIONS

FENESTRATIONNOTES:

1800mm HIGH PRECAST CONCRETE WALL

1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPAL AND NBR REGULATIONS. NO GAP OR OPENING SHALL BE ABLE TO LET THROUGH ABALL OF NOT LESS THAN100mmø, AT ANY GIVENPOSITION OR POINT.

ERF 858

ERF 857

UNIT 28

UNIT 29

1800mm HIGH, 190mmTHICK CONCRETEBLOCKWORK WALL

200 x 600MASS CONCRETE

STRIP FOUNDATION

scale 1 : 100FIRST STOREY PLAN

PALISADE FENCE

300mm HIGH, 190mmTHICK CONCRETEBLOCKWORK WALL

PALISADE FENCE

85mm PLASTER BAND

CONCRETE BLOCKWORK, SMOOTHPLASTERED & PAINTED ON

BOTH SIDES. PLASCON PAINTFINISH IN STRICT ACCORDANCE

WITH MANUFACTURER'S SPECIFICATIONS.

FFL: 98 120

geyser

trapdoor

20 000mm BOUNDARY LINE

20 000mm BOUNDARY LINE

9 0

00m

m B

OU

ND

AR

Y L

INE

9 0

00m

m B

OU

ND

AR

Y L

INE

FIRE WALL TO U/SOF ROOF COVERING

W12

FFL: 98 245

W8

W7D3

D2

W11 W10 W9

EN-SUITE

bic

bic

bic

shwrshwr

bath

wc

wc

whb whb

1413121110

9

8 7

654321

BB

BEDROOM 2carpet

carpetBEDROOM 3

tilesBATHRcarpet

MAIN BEDROOM

BALCONY

tiles

PLATFFO

RM

LEVEL

95 270

15mm PLASTERDETAIL TO

ARCHITECT'SSPECIFICATION

CHIMNEY TO COMPLY WITH ALLRULES & REGULATIONS AS PER

IN SANS 10400-V:2010 4.3ROOF TIMBERS TO STOP A MIN.OF 200mm AWAY FROM INSIDE

WALL OF CHIMNEY.

1800mm HIGH, 140mmTHICK CONCRETE

BLOCKWORK WALL

AD

JA

CE

NT

UN

IT

BO

UN

DA

RY

LIN

E

CE

NT

RE

LIN

E

200 x 600MASS CONCRETE

STRIP FOUNDATION

8 000mm WALLPLATE HEIGHT RESTICTION

scale 1 : 100SOUTH EAST ELEVATION

ROOF:PITCH 1 DEGREE

"KLIPLOK" ROOF SHEETING

FIBRE CEMENTCLADDING

EVACUATED TUBE COLLECTOR ACCORDINGTO SPECIALISTS SPECIFICATIONS

15mm PLASTERDETAIL TO

ARCHITECT'SSPECIFICATION

BRICK WORK. SMOOTHPLASTERED & PAINTED

PLASCON PAINTFINISH ACCORDING TO

MANUFACTURERSSPECIFICATION OR

APPROVED SIMILAR.COLOUR TO ARCHITECT'S

SPECIFICATIONS.

AD

JA

CE

NT

UN

IT

1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPALAND NBR REGULATIONS. NOGAP OR OPENING SHALL BE

ABLE TO LET THROUGH ABALL OF NOT LESS THAN

100mmø, AT ANY GIVENPOSITION OR POINT.

scale 1 : 100NORTH WEST ELEVATION

BO

UN

DA

RY

LIN

E

CE

NT

RE

LIN

E

8 000mm WALLPLATE HEIGHT RESTICTION

1800mm HIGH, 450 X 450mm CONCRETEBLOCKWORK PIERS WITH PALISADEPANELS @ MAX 3500mm C/C. SMOOTH PLASTER& PAINT FINISH. PLASCON PAINTFINISH OR APPROVED SIMILAR.

hwb

re 4

paving

braai

re 1

re 2

re 3

ERF 858

123456

78

91011121314

ZA

ND

VLIE

T D

RIV

E

ST

ER

LIN

G G

RO

VE

CR

ES

CE

NT

ADJACENTERF 857

wc

STAIRS:RISERS: 194mmTREADS: 250mm

W6

W5 W4 W3

W2

W1

CLASS EFIRE DOOR (30min)

TO SANS 1253

FIRE WALL TOU/S OF SLAB P

C R

EIN

FO

RC

ED

CO

NC

RE

TE

LIN

TO

LS

OV

ER

2400 x

2100

mm

SE

CT

ION

AL

OV

ER

HE

AD

GA

RA

GE

DO

OR

20 000mm BOUNDARY LINE

20 000mm BOUNDARY LINE

3100m

mC

WC 9

000m

m B

OU

ND

AR

Y L

INE

9 0

00m

m B

OU

ND

AR

Y L

INE

f/fr

wm

FFL: 95 350

FFL: 95 525

stovesink

D1

B B

DRIVE WAYpaving

CARPORTpaving

tilesLOUNGE

tiles

granolithicscreed

GARAGE

tiles

GUESTWC

tilesDINING

KITCHENtiles

2

2145,11m

0,767

103,28m

57,38%

9,22m²

55,99m²

69,78m²

FOYERtiles

A

A

TO MUNICIPALCONNECTION

ADJACENT

BUILDING LINES (BACK) 5 000mm

1MAX. FLOOR FACTOR

N/AMAX. FLOOR SPACE

N/ABUILDING LINES (STREET)

MAX. HEIGHT (ROOF)

8 000mmMAX. HEIGHT (WALLPLATE)

10 000mm

BUILDING LINES (COMMON)

ERF AREA

THE SITE

AREAS SCHEDULE: TYPE A

SERVITUDES

ZONING

N/A

GR1

180m²

N/A

COUNCIL DRAWINGS:

GROUND STOREY PLAN/SITE PLAN, FIRST STOREY PLAN,ELEVATION, DRAINAGE SECTION,

PERGOLA ELEVATION,BOUNDARY WALL DETAIL

ROOF:PITCH 1 DEGREE "KLIPLOK" ROOF SHEETING

ON 50 x 152mm PAR HARDWOOD PURLIN ON 50 x 228mm PAR HARDWOOD BEAM FIXED TO

TIMBER AND STEEL POST.

D10

D9D8

D7

D6

D5D4

EXISTINGEXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTINGEXISTING

EXISTING

DEMILOSHED

NEW BUILDING WORK

EXISTING WORK

LEGEND

16,22m²

9,22m²

3,12m²

existing

3,12m²

FLOOR FACTOR

FOOTPRINT

proposed

COVERAGE

THE BUILDING: TYPE B

DESCRIPTION TOTAL

BALCONY

154,33m²TOTAL

GROUND STOREY

FIRST STOREY

69,78m²

55,99m²

CARPORT

9,22m²

16,22m²

FFL: 95 525

"S""S"

W14

NEWCOVERED

PATIO

COVERED PATIO

FEB2018

TYPE A

600

12

00 21

009

00

25°

365

25

50

17

02

55

0

100

0

500

0

17

02

55

0

900 2700

15

00

1200

21

00

18

00

600

90

0

21

00

12

00

60

0

21

00

21

00

913

21

00

1800

21

00

2100

21

00

900

21

00

2400860 900

21

00

1760

2400

21

00

15

00

25

50

900

12

00

21

00

90

0

F.F.L.

ACCORDING TO WINDOW MANUFACTURERS SPEC

N/A

W1, W2, W10

3

600 X 900mm ALUMINIUM PROJECTED OUT WINDOW TO MEET "AAAMSA" SPECIFICATION.

EPOXY COATED ALUMINIUM FINISHTO SABS SPEC. COLOUR TOARCHITECT'S SPECIFICATIONS

6mm CLEAR FLOAT GLASS

OTHERS

WINDOW TYPE

WINDOWSCHEDULE

QUANTITY

WINDOW POSITION No.

BURGLAR BARS

IRONMONGERY

WINDOW FINISH

DESCRIPTION / CAT No.

GLAZING

TYPE A

N/A

DOOR

FRAME

DESCRIPTION / CAT No.

IRONMONGERY

BURGLAR BARS

DOOR POSITION No.

QUANTITY

DOORSCHEDULE

DOOR TYPE

DESCRIPTION / CAT No.

FINISH

FINISH

GLAZING

1. THE CONTRACTOR MUST ESTABLISH THE POSITIONS OF BOUNDARY PEGS,EXISTING STRUCTURES & OBSTRUCTIONS BEFORE ANY WORK COMMENCES. 2. ANY EXCAVATION FOR ANY FOUNDATION MUST BE DONE UNTIL STABLE NATURAL GROUND IS REACHED AND NOT IN FILLED GROUND. 3. WHERE A FOUNDATION WALL IS HIGHER THAN 1 500mm A RETAINING WALL ACCORDING TO ENGINEERS SPECIFICATION MUST BE CONSTRUCTED. 4. FLOORSLABS TO BE CAST A MINIMUM OF 170mm (2 BRICK COURSES) ABOVE NATURAL GROUND LEVEL. 5. PREFABRICATED CONCRETE LINTOLS TO BE BUILT IN OVER ALL OPENINGS.LINTOLS MUST HAVE BEARING DISTANCE OF MINIMUM 225mm AT BOTH SIDES.

6. ALL WALLS TO HAVE "Brick-Force" AT EVERY 5TH COURSE.CAVITY WALLS TO HAVE MINIMUM OF 5 X WIRE TIES PER SQ/M. 7. "Brick-Force" FOR MINIMUM 4 BRICK COURSES ABOVE LINTOL HEIGHT. 8. ALL CARE MUST BE TAKEN TO KEEP CAVITIES CLEAN FROM DPC LEVEL TO EAVES LEVEL. 9. BEAM FILLING TO UNDERSIDE OF ROOF COVER. 10. ROOF OVERHANG : 300mm 11. ANY PERCEIVED INDISTINCTNESS OR CONTRADICTION IN THE DOCUMENTS MUST IMMIDIATELY BE CLEARED WITH THE ARCHITECT.

12. ALL GUTTERS AND DOWNPIPES TO BE ALLUMINIUMAND TO BE INSTALLED AS MANUFACTURER'S SPECIFICATION.

NOTES

RIDER PLAN FOR MSP DEVELOPMENTS

KRAAIFONTEIN

L201695

drw no.

drawn

rev.

date

job no.

AS SHOWN@ A1

scale

drawing title

LRB

project

revision/issueno. date

architect

CONTRACTOR

COUNCIL DRAWINGS:

SECTION A-A, SECTION B-B,SCHEDULES

Old Castle Brewery Unit 005 6 Beach Road Woodstock 7925

Email. [email protected]. 021 447 1125Fax. 021 447 7347Cell. 082 823 1449

IN ASSOCIATION WITH WILHELM MARTIN BASSON ARCHITECTS cc.WORCESTER

H. LE ROUX BASSONNDIP ARCH(CAPE TECH)

B.BUILD(UPE) B.ARCH(UPE)SACAP REG. NO. 6 135

ALL WORK TO BE DONE IN ACCORDANCE WITH THENATIONAL BUILDING REGULATIONS (SOUTH AFRICANCODE OF PRACTICE) AND BUILDING STANDARDS ACT,ACT SABS 10400:2010

ALL SPECIFICATIONS ETC. TO BE IN ACCORDANCEWITH MODEL PREAMBLES FOR TRADES AS PUBLISHEDBY THE ASSOCIATION OF SOUTH-AFRICAN QUANTITYSURVEYORS.

ALL MATERIALS ETC. TO BE FITTED IN STRICTACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS.

CONTRACTOR TO ALLOW FOR ARCHITECTS BOARD ALL ELECTRICAL WIRES IN WALLS, FLOORS ANDCONCRETE CEILINGS TO RUN IN SABS APPROVED CONDUITS

REGULATIONS AND REQUIREMENTS OF ALL RELEVANTAUTHORITIES TO BE ADHERED TO.CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELSON SITE BEFORE COMMENCING WITH WORK.FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TOSCALED MEASUREMENTS.ALL STRUCTURAL DESIGN TO BE THE RESPONSIBILITYOF A PROFESSIONAL ENGINEER.COPYRIGHT RESERVED.

GENERAL NOTES

TYPICAL SOFFIT DETAILscale 1 : 50

FIBRE CEMENT SOFFIT NAILED TO UNDERSIDE OF TRUSS.PAINTEDAND FINISHED WITH QUARTER ROUND.

FIBRE CEMENT SOFFIT NAILED TO UNDERSIDE OFTRUSS.PAINTED AND FINISHED WITH QUARTER ROUND.

6,4mm THICK SKIMMED "RHINO BOARD" CEILING ON 38 X 38mm SAP BRANDERINGAT MAX. 400mm C/C, SPANNING IN ONE DIRECTION ONLY. CEILING FIXED TOBRADERING USING 38mm GALVANISED SEMI-CLOUT NAILS AT 150mm C/C.ALL NAILS TO BE PUNCHED IN & STOPPED WITH ONE COAT OF ENAMEL PAINT& SANDED DOWN WHEN DRY. APPLY A UNIVERSAL UNDERCOAT OVER METAL COVERSTRIPS FOLLOWED BY A GOOD QUALITY PVA EMULSION BASED PAINT & FINAL COAT.100mm "ISOTHERM - 11.5kg/m3" THERMAL INSULATION LAID ONTOP OF CEILING.

ROOF:PITCH 25 DEGREE0,47mm ALUMINIUM-ZINK "SAFINTRA - CLASSICORR" CORRUGATED PROFILE ROOF SHEETINGON "ALUCUSHION BUBBLEFOIL FR DOUBLE-SIDED" ON 76 x 50mm SAP PURLINS @ MAX.600mm ON PREFABRICATED TRUSSES BY GANGNAIL OR APPROVED SIMILAR @ MAX.600mm C/C ON 114 X 38mm SAP WALLPLATES. WALLPLATES TO BE ANCHORED DOWN BY30 X 1,6mm THICK GALVANIZED HOOP IRON. HOOP IRON TO BE TIED BACK INTO WALLSTO MINIMUM DEPTH OF 600mm. HOOP IRON TO BE FOLDED UP & OVER WALL PLATES &RAFTERS AND TO BE NAILED DOWN AT BOTH ENDS. 100 X 75mm SEAMLESS ALUMINIUMGUTTERS WITH ALUMINIUM DOWNPIPES, 225 X 15mm PLAIN HIGH DENSITY FIBRE-CEMENTFACIA PAINTED & FIXED TO ROOF CONSTRUCTION ACCORDING TO MANUFACTURER'SSPECIFICATIONS.

EXISTINGMASS CONCRETE

STRIP FOUNDATION

REINFORCED CONCRETESTAIRCASE TO ENGINEER'S

SPECIFICATIONS

1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPALAND NBR REGULATIONS. NOGAP OR OPENING SHALL BE

ABLE TO LET THROUGH ABALL OF NOT LESS THAN

100mmø, AT ANY GIVENPOSITION OR POINT.

FIRE WALL TO U/SOF ROOF COVERING

EXISTING CONCRETE SLAB

STEPPED DPC WEEPHOLESAT EVERY 4TH MORTAR

JOINT. MIN. 150mm ABOVE NGL.

STEPPED DPC WEEPHOLESAT EVERY 4TH MORTAR

JOINT.

EN-SUITE

FFL: 98 245

FFL: 95 525

KITCHEN

SECTION A - Ascale 1 : 50

SECTION B - Bscale 1 : 50

CHIMNEY TO COMPLY WITH ALLRULES & REGULATIONS AS PER

IN SANS 10400-V:2010 4.3ROOF TIMBERS TO STOP A MIN.OF 200mm AWAY FROM INSIDE

WALL OF CHIMNEY.

ROOF:PITCH 25 DEGREE 0,47mm ALUMINIUM-ZINK "SAFINTRA - CLASSICORR" CORRUGATEDPROFILE ROOF SHEETING ON "ALUCUSHION BUBBLEFOIL FR DOUBLE-SIDED" ON 76 x 50mm SAP PURLINS @ MAX.600mm ON PREFABRICATED TRUSSES BY GANGNAIL OR APPROVED SIMILAR @ MAX. 600mm C/C ON 114 X 38mm SAP WALLPLATES. WALLPLATES TO BE ANCHORED DOWN BY 30 X 1,6mm THICK GALVANIZED HOOPIRON. HOOP IRON TO BE TIED BACK INTO WALLS TO MINIMUM DEPTH OF 600mm. HOOP IRON TO BE FOLDED UP & OVER WALL PLATES & RAFTERS AND TO BE NAILED DOWN AT BOTH ENDS. 100 X 75mm SEAMLESS ALUMINIUM GUTTERS WITH ALUMINIUM DOWNPIPES, 225 X 15mm PLAIN HIGH DENSITY FIBRE-CEMENT FACIAPAINTED & FIXED TO ROOF CONSTRUCTION ACCORDING TO MANUFACTURER'SSPECIFICATIONS.

6,4mm THICK SKIMMED "RHINO BOARD" CEILING ON 38 X 38mm SAP BRANDERINGAT MAX. 400mm C/C, SPANNING IN ONE DIRECTION ONLY. CEILING FIXED TOBRADERING USING 38mm GALVANISED SEMI-CLOUT NAILS AT 150mm C/C.ALL NAILS TO BE PUNCHED IN & STOPPED WITH ONE COAT OF ENAMEL PAINT& SANDED DOWN WHEN DRY. APPLY A UNIVERSAL UNDERCOAT OVER METAL COVERSTRIPSFOLLOWED BY A GOOD QUALITY PVA EMULSION BASED PAINT & FINAL COAT.100mm "ISOTHERM - 11.5kg/m3" THERMAL INSULATION LAID ONTOP OF CEILING.

STEPPED DPC WEEPHOLES ATEVERY 4TH MORTAR JOINT

ABOVE OPENINGS.

BEDROOM 2

DININGROOM

GARAGE

FFL: 98 245

FFL: 95 525

PC REINFORCEDCONCRETE LINTOL

BEDROOM 3

PC REINFORCEDCONCRETE LINTOL

BALCONY

FFL: 95 350

FIBRE CEMENT SOFFIT NAILED TO UNDERSIDE OF TRUSS.PAINTED

AND FINISHED WITH QUARTER ROUND.

WD-02

EXISTING

EXISTING

EXISTING

EXISTINGEXISTING

EXISTING

EXISTING

EXISTING CONCRETE SLAB

EXISTINGMASS CONCRETE

STRIP FOUNDATION

EXISTING CONCRETE SLABEXISTING CONCRETE SLAB

EXISTING CONCRETE SLAB

F.F.L.F.F.L.F.F.L.F.F.L.

F.F.L.

"S""S"

F.F.L.

"S" "S"

"S"

F.F.L.

F.F.L.

"S" "S"

F.F.L.F.F.L.

"S"

F.F.L.

ACCORDING TO WINDOW MANUFACTURERS SPEC

N/A

W11

2 700 X 600mm ALUMINIUM PROJECTED OUT WINDOW TO MEET "AAAMSA" SPECIFICATION.

EPOXY COATED ALUMINIUM FINISHTO SABS SPEC. COLOUR TOARCHITECT'S SPECIFICATIONS

6mm CLEAR FLOAT GLASS

N/A

ACCORDING TO WINDOW MANUFACTURERS SPEC

N/A

W6, W12

2

1 200 X 1 500mm TOP-HUNG ALUMINIUM WINDOWTO MEET "AAAMSA" SPECIFICATION.

EPOXY COATED ALUMINIUM FINISHTO SABS SPEC. COLOUR TOARCHITECT'S SPECIFICATIONS

6mm CLEAR FLOAT GLASS

ACCORDING TO WINDOW MANUFACTURERS SPEC

N/A

3

W4, W5, W7

600 X 1 800mm ALUMINIUM PROJECTED OUT WINDOW TO MEET "AAAMSA" SPECIFICATION.

EPOXY COATED ALUMINIUM FINISHTO SABS SPEC. COLOUR TOARCHITECT'S SPECIFICATIONS

6mm CLEAR FLOAT GLASS

N/A

ACCORDING TO WINDOW MANUFACTURERS SPEC

N/A

W3, W8, W9

3

900 X 900mm ALUMINIUM PROJECTED OUT WINDOW TO MEET "AAAMSA" SPECIFICATION.

EPOXY COATED ALUMINIUM FINISHTO SABS SPEC. COLOUR TOARCHITECT'S SPECIFICATIONS

6mm CLEAR FLOAT GLASS

N/A

GLAZING

DESCRIPTION / CAT No.

WINDOW FINISH

IRONMONGERY

BURGLAR BARS

WINDOW POSITION No.

QUANTITY

WINDOWSCHEDULE

WINDOW TYPE

OTHERS

N/A

D7, D8, D9, D10

4

N/A

45 x 90mm REBATED HARDWOOD FRAME (NO SILL) ACCORDING TO MANUFACTURER'S SPECIFICATION.

913 x 2 100 mm HOLLOW CORE VENEERED DOOR

N/A

1

ACCORDING TO MANUFACTURERSSPECIFICATION

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC.COLOUR TO ARCHITECT'S SPECIFICATIONS

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC.COLOUR TO ARCHITECT'S SPECIFICATIONS

1 800 x 2 100mm ALUMINIUMSLIDING DOOR TO MEET "AAAMSA"SPECIFICATIONS.

D6

6mm TOUGHENED SAFETY GLASS

ALLOW P.C. SUM OF R500

N/A

1

6mm CLEAR FLOAT GLASS6mm TOUGHENED SAFETY GLASS WHERE INDICATED

ACCORDING TO MANUFACTURERSSPECIFICATION

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC. COLOUR TO ARCHITECT'S SPECIFICATIONS

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC. COLOUR TO ARCHITECT'S SPECIFICATIONS

2 100 x 2100mm ALUMINIUMSLIDING DOOR WITH PROJECTOUT SIDELIGHTS TO MEET "AAAMSA" SPECIFICATIONS.

1

N/A

HOT DIPPED GALVANIZED PRESSED STEEL DOOR FRAME WITHOUT CILL.

PLASCON PAINT FINISH ACCORDINGTO MANUFACTURERS SPECIFICATIONOR APPROVED SIMILAR.

813 x 2032mm MASONITE DOOR WITH ONE HOUR FIRE RATING

N/A

1

ACCORDING TO MANUFACTURERSSPECIFICATION

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC.COLOUR TO ARCHITECT'S SPECIFICATIONS

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC.COLOUR TO ARCHITECT'S SPECIFICATIONS

2 400 x 2 100mm ALUMINIUMSLIDING DOOR TO MEET "AAAMSA"SPECIFICATIONS.

N/A

1

N/A

6mm TOUGHENED SAFETY GLASS

MERANTI DOOR FRAME WITH CILLAS PER MANUFACTURER'S SPECIFICATION.

PLASCON VELVAGLO PAINTFINISH ACCORDINGTO MANUFACTURERS SPECIFICATIONOR APPROVED SIMILAR.

813 x 2 032 mm FL & B FLATBACKMERANTI DOOR WITH 860 x 2100mmWITH PROJECT OUT SIDE LIGHT TO MEET "AAAMSA" SPECIFICATION.

EPOXY COATED ALUMINIUM FINISH TO SABS SPEC. COLOUR TO ACHITECT'S SPECIFICATIONS

ACCORDING TO DOOR MANUFACTURER'S SPECIFICATION.

2 400 x 2 100mm ZINCALUMESECTIONAL OVERHEAD GARAGE DOOR.

ACCORDING TO MANUFACTURERS SPECIFICATION

N/A

N/A

1

GLAZING

FINISH

FINISH

DESCRIPTION / CAT No.

DOOR TYPE

DOORSCHEDULE

QUANTITY

DOOR POSITION No.

BURGLAR BARS

IRONMONGERY

DESCRIPTION / CAT No.

FRAME

DOOR

1

TYPE E

N/A

TYPE DTYPE CTYPE B

N/A

PLASCON VELVAGLO PAINTFINISH ACCORDINGTO MANUFACTURERS SPECIFICATIONOR APPROVED SIMILAR.

PLASCON VELVAGLO PAINTFINISH ACCORDINGTO MANUFACTURERS SPECIFICATIONOR APPROVED SIMILAR.

TYPE GTYPE F

ALLOW P.C. SUM OF R500

D5

TYPE E

N/A

N/A

PLASCON VELVAGLO PAINTFINISH ACCORDINGTO MANUFACTURERS SPECIFICATIONOR APPROVED SIMILAR.

D4

TYPE D

ALLOW P.C. SUM OF R500

6mm TOUGHENED SAFETY GLASS

D3

TYPE C

PLASCON VELVAGLO PAINTFINISH ACCORDINGTO MANUFACTURERS SPECIFICATIONOR APPROVED SIMILAR.

D2

TYPE B

ACCORDING TO ARCHITECT'S SPECIFICATION

D1

TYPE A

FEB2018

PC REINFORCEDCONCRETE LINTOL

25mPA 600 x 200mmMASS STRIP

FOUNDATION

STEPPED DPC WEEPHOLES AT

EVERY 4TH MORTAR JOINT

ABOVE OPENINGS.

NEWCOVERED

PATIO

ROOF: PITCH 3 DEGREE "KLIPLOK" ROOF SHEETING ON "ALUCUSHION BUBBLEFOIL FRDOUBLE-SIDED" ON 75 x 50mm SAP PURLINS @ MAX. 600mm ON 114 x 38mm SAP

WALLPLATES. WALLPLATES TO BE ANCHORED DOWN BY 30 x 1,6mm THICK GALVANIZED HOOP IRON. HOOP IRON TO BE TIED BACK INTO WALLS TO MIN. DEPTH

OF 600mm. HOOP IRON TO BE FOLDED UP & OVER WALLPLATES & RAFTERS AND TO BENAILED DOWN AT BOTH ENDS. 100 x 75mm SEAMLESS ALUMINIUM GUTTERS WITH UPVC DOWNPIPES.

225 x 15mm PLAIN HIGH DENSITY FIBRE-CEMENT FASCIA PAINTED & FIXED TO ROOF CONSTRUCTIONACCORDING TO MANUFACTURER'S SPECIFICATIONS.

F.F.L.

ACCORDING TO WINDOW MANUFACTURERS SPEC

N/A

EPOXY COATED ALUMINIUM FINISHTO SABS SPEC. COLOUR TOARCHITECT'S SPECIFICATIONS

6mm CLEAR FLOAT GLASS

N/A

TYPE F

1

W14

900 x 1 200mm ALUMINIUM TOP-HUNG WINDOW TO MEET"AAAMSA" SPECIFICATIONS.

TYPE A

Workstation2
Typewriter
SECTION B-B
Workstation2
Typewriter
SCALE 1:50
Workstation2
Rectangle
Workstation2
Rectangle
Workstation2
Rectangle
Workstation2
Typewriter
PITCH 3
Workstation2
Typewriter
DOUBLE-
Workstation2
Typewriter
RAFTERS @ MAX. 600mm C/C ON 114 x 38mm