2
1 14 13 2 7 8 (UB-5365) (UB-5865) 3 16 15 4 9 10 “LL” “UL” “UR” “LR” 5 18 17 6 11 12 19 36 35 20 27 28 A C B 2025 mm (6 ft. 7 3 / 4 in.) 1900 mm (6 ft. 2 13 / 16 in.) 1775 mm (5 ft. 9 7 / 8 in.) The current time must be set when using the unit for the first time. (Refer to the operating instructions for details on setting the current time.) A B C . - - PNQX5935ZA F1112NS0 23 40 39 24 31 32 2 . ) : , , < ; < ; , / 21 38 37 22 29 30 1 . , , 25 26 33 34 41 (For EU only) © Panasonic System Networks Co., Ltd. 2012 Printed in Malaysia * * - - 0 * * * * For using the optional stand For wall mounting Installation Manual (for qualified service personnel) Electronic Board Model No. UB-5365 / UB-5865 Assembling the Optional Stand and Electronic Board Stand (UE-608005) accessories Electronic board accessories Required tools (not included) & × 2 , × 1 (UB-5365) 2 × 1 8 × 2 ' × 2 - × 1 (UB-5865) 3 × 1 9 × 1 ( × 6 . × 10 4 × 2 : × 1 ) × 20 / × 4 5 × 2 ; × 6 * × 2 0 × 4 6 × 4 < × 6 + × 1 1 × 4 7 × 2 % × 1 ) × 6 - × 1 1 × 1 & × 1 * × 6 . × 1 2 ' × 6 + × 1 / × 1 3 × 1 ( × 6 , × 7 0 × 1 4 × 1 Please hand this USB cable to the customer. M6 × 45 M6 × 15 M6 × 60 5 mm ( 3 / 16 in.) M4 × 10 M4 × 45 M4 × 20 10 mm ( 13 / 32 in.)

UB-5365 PNQX5935ZA eng p1 20121119 - Shopify

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UB-5365 PNQX5935ZA eng p1 20121119 - Shopify

1

1413

2

7 8

(UB-5365)

(UB-5865)

3

1615

4

9 10

“LL”

“UL”

“UR”

“LR”

5

1817

6

11 12

19

3635

20

27 28

A

C

B

2025 mm(6 ft. 7 3/4 in.)

1900 mm(6 ft. 2 13/16 in.)

1775 mm(5 ft. 9 7/8 in.)

The current time must be set when using the unit for the first time. (Refer to the operating instructions for details on setting the current time.)

A

B

C

PNQX5935ZA F1112NS0

23

4039

24

31 32

21

3837

22

29 30

25 26

33 34

41

(For EU only)

© Panasonic System Networks Co., Ltd. 2012 Printed in Malaysia

For using the optional stand

For wall mounting

Installation Manual (for qualified service personnel)

Electronic Board

Model No. UB-5365 / UB-5865

� Assembling the Optional Stand and Electronic Board

Stand (UE-608005) accessories

Electronic board accessories

Required tools (not included)

× 2 × 1(UB-5365) × 1 × 2

× 2 × 1(UB-5865) × 1 × 1

× 6 × 10 × 2 × 1

× 20 × 4 × 2 × 6

× 2 × 4 × 4 × 6

× 1 × 4 × 2

× 1 × 6 × 1 × 1

× 1 × 6 × 1

× 6 × 1 × 1 × 1

× 6 × 7 × 1× 1

Please hand this USB cable tothe customer.

M6 × 45 M6 × 15

M6 × 60

5 mm (3/16 in.)

M4 × 10

M4 × 45

M4 × 20

10 mm (13/32 in.)

UB-5365_PNQX5935ZA_eng_p1_20121119.pdf 1 2012/11/19 15:26:23

Page 2: UB-5365 PNQX5935ZA eng p1 20121119 - Shopify

H: 900 mm (2 ft. 11 7/16 in.)

H: 812.8 mm (2 ft. 8 in.)

V: 940 mm (3 ft. 1 in.)

H: 518 mm (20 3/8 in.)H: 440 mm (17 11/32 in.)

Center of the electronic board (screen)UB-5865

Center of the electronic board (screen) UB-5365

• Panasonic assumes no responsibility for injuries or property damage resulting from failures arising out of improper installation or operation inconsistent with this documentation.

For Your SafetyTo prevent severe injury and loss of life, read this section carefully before using the unit to ensure proper and safe operation of your unit.

• This section explains the graphic symbols used in this manual.

Denotes a potential hazard that could result in serious injury or death.

Denotes hazards that could result in minor injury or damage to the unit.

These symbols are used to alert operators to a specific operating procedure that must not be performed.

These symbols are used to alert operators to a specific operating procedure that must be emphasized in order to operate the unit safely.

WARNING

CAUTION

WARNING

� Notes in the operating instructions or notes of labels on the cabinet, chassis or parts should be observed.

� Be sure to use the specified parts for the installation. Otherwise, it may cause fire, electric shock or injury.

� Plug the power cord firmly into an AC outlet. Otherwise, it can cause fire or electric shock.

� Safety check must be done by qualified service personnel after installing this option.

� Have the unit installed, removed and disposed of only by qualified service personnel.

� If the unit is hung on a wall, confirm the wall must be capable of supporting at least the following weight.1,568 N (160 kgf)

� Be sure to disconnect the power cord while installing the unit. Otherwise, it may cause electric shock or injury.

� To ensure safe operation the power cord supplied must be inserted into a standard three-prong AC outlet which is effectively grounded (earthed) through the normal wiring.

� The fact that the equipment operates satisfactorily does not imply that the power point is grounded (earthed) and that the installation is completely safe. For your safety, if in any doubt about the effective grounding (earthing) of the power point, consult a qualified electrician.

� Do not use damaged plugs or warped outlets. Otherwise, it may cause fire, electric shock, or short circuit.

� During thunderstorms, do not touch the unit and plug. It may cause an electric shock.

� Do not alter the unit or modify any parts. Alteration or modification can cause fire or electric shock.

CAUTION

� Be sure to put on a glove to avoid electric shock or injury.

� Confirm both sides of the screen are hung in the same height slots.

� Make sure to tighten the height adjustment handles after adjusting the screen height.

� Confirm the bolts of the unit are certainly caught by the wall mounting plate by pulling the unit after hanging the unit on the wall mounting plate if the unit is mounted on a wall.

� After installing or moving the electronic board, lock the casters and set the fall-prevention extension legs.

� Move this unit with two persons. Otherwise, this unit may fall down and cause injury.

� When using the stand, be sure to watch your step so that you do not bump into or trip over the fall-prevention extension legs.The label of precautions is attached to the stand UE-608005 (sold separately).

� For your safety, connect the lead wire securely to the terminal.(Refer to step 31.)

Locking the casters(Push to lock)

� Do not position the unit in a location where it is unstable.

� Do not attach the electronic board to mortared walls. Accidental electric leakage from the wall mounting plate bolts to metal laths or wire laths can cause heat, smoke or fire.

Cautions for Wall Mounting ConstructionWhich method should be used to mount the electronic board depends greatly on the structure of the wall. The system to be mounted on the wall is heavy. Before proceeding with installation, therefore, consult with the building manager, maintenance engineer or designer to verify that the wall has a structure strong enough to support the weight of the system. For safety, install the electronic board only after thoroughly understanding the type of walls, the appropriate types of screws and the construction method.

� Necessary Tools and PartsTools Required for Assembly

Phillips Head Screwdriver . . . . . . 1

Tools and Parts Required for Wall-Mounting Work

Drill, measuring tape, level, dust pump, hammer, torque driver (capable to specify torque*1)*1 The range in which the torque can be specified is limited. Use the correct

torque. [Recommended tightening torque: 5.2 N•m (53 kgf•cm)]

� Checkpoints to be Observed While Working

1 Work-Related Safety Precautions• Before mounting the electronic board, read through the following points, and

take care to avoid accidents.— To ensure that the work is accomplished safely and properly, make it a

basic rule to strictly observe all other applicable aspects of safety control.— If there is a chance that the unit has ended up being deformed or damaged

by unexpected impact while it was being transported and installed, do not install it without taking appropriate measures. Otherwise, it may fall off the wall.

2 Concerning Installation• The electronic board is for indoor use. It cannot be used outdoors. Neither can

it be installed or used in the following kinds of places.— Places where it will be directly exposed to rain or water (including under

the eaves of a house)— Places with a lot of steam or grease such as manufacturing plants or

kitchens, places with special environments such as those with combustible atmospheres

— Seaborne or coastal places and places where corrosive gases are given off— Places where the operating temperature range of the electronic board

[temperature: 10 °C to 35 °C (50 °F to 95 °F), humidity: 30 % to 80 %] will be exceeded

• To prevent deformation and discoloring, avoid installing the unit in places exposed to direct sunlight or near heating or cooling appliances, etc.

3 Concerning the Installation Surface• Avoid mounting the unit on a wall, which is not a principal structure

component [a concrete wall which is at least 120 mm (4 3/4 in.) thick], with a plasterboard, plywood or other such construction since these walls are weak. If mounting on such a wall is unavoidable, reinforce the wall adequately (by ensuring that its ultimate strength will be at least as great as the specified pull-out strength of the anchors).

4 Concerning the Screws and Bolts Used• When obtaining anchors and bolts locally, be absolutely sure that they satisfy

the required specifications.• Use the values recommended by the manufacturer of the anchors used for

the depth to which the anchors are to be embedded in the wall.• Use M6 bolts when the anchors have internal screw threads.• Ensure that the M6 bolt has a mated length of 9 mm (11/32 in.) or longer.

(Below)

• Ensure that the M6 bolts do not strike the bottoms of the anchors, and check that they have been tightened up securely.

• Recommended tightening torque: 5.2 N•m (53 kgf•cm)

5 Other Checkpoints• Make sure that the location is large enough to accommodate the electronic

board.

• Place the AC outlet in the position outlined below.— Within 3 m (9ft. 10 1/8 in.) of the electronic board mounting position— Not behind the electronic board

Anchor . . . . . . . . . . . . . . . 4M6 Bolt . . . . . . . . . . . . . . . 4Flat Washer . . . . . . . . . . . 4Spring Washer . . . . . . . . . 4

The specified pull-out strength is required per anchor.M6 anchor bolts are used when installing the electronic board on the wall.[Specified pull-out strength: 784 N (80 kgf)]

UB-5365 Height: greater than 1,480 mm (4 ft. 10 9/32 in.)Width: greater than 1,580 mm (5 ft. 2 7/32 in.)

UB-5865 Height: greater than 1,480 mm (4 ft. 10 9/32 in.)Width: greater than 1,950 mm (6 ft. 4 25/32 in.)

M6 BoltSpring Washer

Installation SurfaceAnchor (internal thread)9 mm (11/32 in.) or longer

Flat Washer [max. diameter of 16 mm (5/8 in.)]

� Wall-mounting and electronic board assembly

1 Use the template from the Installation Manual to mark the position on the wall.

2 Drill 4 holes in the wall.

3 Hammer in the anchors.

4 Fix electronic board accessories and (board attachments) to the wall with M6 screws.

5 • Refer to steps 9 and on under “� Assembling the Optional Stand and Electronic Board”.

• Steps 19 to 23 and 32 are unnecessary.

A B C

A B C

H: 900 mm (2 ft. 11 7/16 in.)

H: 812.8 mm(2 ft. 8 in.) V: 940 mm

(3 ft. 1 in.)

• Make marks at and or and .A C B C

UB-5365_PNQX5935ZA_eng_p2_20121119.pdf 1 2012/11/19 15:33:25