1 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE Dimensions Physical Specification Specifications Part Number: Length: Width: Container Height: Total Height (with terminal): Approx Weight: Terminal Type Container Material Rated Capacity Max Discharge Current Internal Resistance Discharge Characteristics Design Floating Life at 20°C Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For higher temperatures the time interval will be shorter. ISO9001 ± ± ± ± mm mm mm mm ( ( ( ( ) ) ) ) inches inches inches inches Normal Voltage Normal Capacity (20HR) Standard Terminal Optional Terminal Standard Option Flame Retardant Option (FR) Operating Temp. Range Normal Operating Temp. Range Cycle Use Standby Use Capacity affected by Temperature Discharge: Charge: Storage: Inital Charging Current less than ABS ABS (UL94:VO) (20hr,1.80V/cell, 25°C / 77°F) (10hr,1.80V/cell, 25°C / 77°F) (5hr,1.75V/cell, 25°C / 77°F) (3hr,1.75V/cell, 25°C / 77°F) (1hr,1.60V/cell, 25°C / 77°F) No limit on Initial Charging Current Voltage Temp. Coefficient Temp. Coefficient Voltage Approx kg kg ( lbs) 12V 9AH F1 Terminal 10 Years 14.4V ~ 15.0V at 25°C(77°F) -30mV/°C 13.5V ~ 13.8V at 25°C(77°F) -20mV/°C 40°C (104°F) 103% 25°C (77°F) 100% 0°C (32°F) 86% 2.70A 12V 9AH F1 F2 9.00 AH/0.450A 8.31 AH/0.831A 7.55 AH/1.51A 6.84 AH/2.28A 6.24 AH/6.24A 135A (5s) Approx 17mΩ 5.86 2.66 5.95 2.56 3.70 3.92 1 1 1 1 151 65 94 99.5 UHR 9-12 UHR 9-12 High Rated UHR 9-12 -15 ~ 50°C (5 ~ 122°F) 0 ~ 40°C (5 ~ 104°F) -15 ~ 40°C (5 ~ 104°F) 25 ± 3°C (77 ± 5°F)

UHR 9-12 12V 9AHtashi.al/wp-content/uploads/2016/11/UHR9-12.pdf · -20 -10 0 1 0 20 3 0 4 0 50 C a p a c i t y (%) Tempe rature(0C ) 0 .17 C 1 . 0 C Battery temperature 20 68 30 0C

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UHR 9-12 12V 9AHtashi.al/wp-content/uploads/2016/11/UHR9-12.pdf · -20 -10 0 1 0 20 3 0 4 0 50 C a p a c i t y (%) Tempe rature(0C ) 0 .17 C 1 . 0 C Battery temperature 20 68 30 0C

1Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United KingdomTel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected]

www.ultracell.co.uk

ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

Dimensions

Physical Specification

Specifications

Part Number:

Length:

Width:

Container Height:

Total Height (with terminal):

Approx Weight:

Terminal Type

Container Material

Rated Capacity

Max Discharge CurrentInternal ResistanceDischarge Characteristics

Design Floating Life at 20°CSelf Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For higher

temperatures the time interval will be shorter.

ISO9001

±

±

±

±

mm

mm

mm

mm

(

(

(

(

)

)

)

)

inches

inches

inches

inches

Normal Voltage

Normal Capacity (20HR)

Standard Terminal

Optional Terminal

Standard Option

Flame Retardant Option (FR)

Operating Temp. Range

Normal Operating Temp. Range

Cycle Use

Standby Use

Capacity affected by Temperature

Discharge:

Charge:

Storage:

Inital Charging Current less than

ABS

ABS (UL94:VO)

(20hr,1.80V/cell, 25°C / 77°F)

(10hr,1.80V/cell, 25°C / 77°F)

(5hr,1.75V/cell, 25°C / 77°F)

(3hr,1.75V/cell, 25°C / 77°F)

(1hr,1.60V/cell, 25°C / 77°F)

No limit on Initial Charging Current Voltage

Temp. Coefficient

Temp. Coefficient

Voltage

Approx kgkg ( lbs)

12V 9AH

F1 Terminal

10 Years

14.4V ~ 15.0V at 25°C(77°F) -30mV/°C

13.5V ~ 13.8V at 25°C(77°F) -20mV/°C

40°C (104°F) 103%

25°C (77°F) 100%

0°C (32°F) 86%

2.70A

12V

9AH

F1

F2

9.00 AH/0.450A

8.31 AH/0.831A

7.55 AH/1.51A

6.84 AH/2.28A

6.24 AH/6.24A

135A (5s)

Approx 17mΩ

5.862.66

5.95

2.56

3.70

3.92

1

1

1

1

151

65

94

99.5

UHR 9-12

UHR 9-12

High Rated

UHR 9-12

-15 ~ 50°C (5 ~ 122°F)

0 ~ 40°C (5 ~ 104°F)

-15 ~ 40°C (5 ~ 104°F)

25 ± 3°C (77 ± 5°F)

Page 2: UHR 9-12 12V 9AHtashi.al/wp-content/uploads/2016/11/UHR9-12.pdf · -20 -10 0 1 0 20 3 0 4 0 50 C a p a c i t y (%) Tempe rature(0C ) 0 .17 C 1 . 0 C Battery temperature 20 68 30 0C

2

Constant Current Discharge (Amperes) at 25°C (77°F)

Constant Power Discharge (Watts) at 25°C (77°F)

Discharge Characteristics Float Charging Characteristics

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life

Self Discharge Characteristics

Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United KingdomTel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected]

www.ultracell.co.uk

ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO9001

La construcción de la batería será tipo AGM con ABS case (celda cerrada en la que se encuentran las placas de plomo, separador y electrolito contenidos. Se compone normalmente de célula y cubierta que están permanentemente unidas)

0 4 8 12 16 20 24 28 32 36

2.0

2.1

2.2

2.3

2.4

(V /cell)(A)

0.02C

0C

0.04C

0.06C

0.08C

0.10C

%

20

40

60

80

100

120

C hargeVolume

C harging C urrent

C harging Voltage

After 5 0% D ischarge

After 1 00% D ischarge

C harge V oltage(C onstant 2.2 5V /cell)

C harged V olume

C harging C urrent

00.1C A-2.25V /cell temperature25C

C harging Time(Hours)

0.05C

2 0 C.

120

100

80

60

40

20

0-20 -10 0 1 0 20 3 0 4 0 50

Cap

acity

(%)

Tempe rature( )0C

0.17C

1.0 C

Batte ry temperature

2068

0C3086

40104

50122 OF

0

2

3

5

810

12

Charging vol tage :2.25V/cell

0.05C

1 2 4 6 810 20 40 60 2 4 6 8 10 20 40 60 2 4 6 8 10 20

8.0

9.0

10.0

11.0

12.0

13.0

0.092 C0.17C

0.4C0.66C1.3C

2.2C

4C5C7C10C

S min H

Discharge Time

12V BatteryV

0Te mpera ture:25C

4.0

4.5

5.0

5.5

6.0

6.5

6V BatteryV

Term

inal

Vol

tage

(V)

1.8 5V /ce ll

1.8 0V /ce ll

1.7 5V /ce ll

1.7 0V /ce ll

1.6 7V /ce ll

1.6 0V /ce ll

5m in 10 m in 15 m in 30 m in 45 m in 1h 2h 3h 4h 5h 6h 8h 10 h 20 h20 m inF.V/ Tim e

30.8 21.5 16.1 13.1 10.1 7.24 5.65 3.12 2.19 1.72 1.44 1.25 0.98 0.812 0.446

34.3 23.2 17.1 13.9 10.5 7.42 5.80 3.18 2.23 1.76 1.47 1.28 1.00 0.831 0.450

37.9 24.8 18.0 14.5 10.8 7.61 5.93 3.24 2.28 1.80 1.51 1.30 1.03 0.843 0.455

41.7 26.3 18.6 15.0 11.1 7.77 6.02 3.30 2.32 1.83 1.54 1.33 1.05 0.858 0.463

43.9 27.4 19.4 15.6 11.3 7.95 6.13 3.35 2.36 1.87 1.57 1.36 1.06 0.874 0.469

46.3 28.5 20.2 16.3 11.7 8.08 6.24 3.40 2.40 1.91 1.60 1.39 1.08 0.887 0.472

5m in 10 m in 15 m in 30 m in 45 m in 1h 2h 3h 4h 5h 6h 8h 10 h 20 h20 m inF.V/ Tim e

1.8 5V /ce ll

1.8 0V /ce ll

1.7 5V /ce ll

1.7 0V /ce ll

1.6 7V /ce ll

1.6 0V /ce ll

57.5 40.3 30.2 24.7 19.2 13.9 10.9 6.05 4.27 3.36 2.83 2.45 1.93 1.61 0.883

62.0 42.6 31.6 26.0 19.8 14.1 11.1 6.13 4.32 3.42 2.87 2.50 1.98 1.64 0.890

67.8 45.0 33.0 26.9 20.2 14.4 11.3 6.22 4.39 3.49 2.93 2.54 2.01 1.66 0.898

73.6 47.1 33.7 27.7 20.7 14.6 11.5 6.32 4.47 3.55 2.98 2.59 2.05 1.69 0.913

76.4 48.3 34.8 28.5 21.0 14.9 11.6 6.40 4.54 3.59 3.04 2.64 2.08 1.72 0.925

79.2 49.6 35.6 29.2 21.3 15.0 11.7 6.46 4.59 3.66 3.09 2.69 2.11 1.74 0.929

S torage T ime(Months)

Rem

aini

ng C

apac

ity(%

)

8 10 120

4 6

60

80

100

0 2

20

40

025 C030 C

040 C

010 C A

B

C

No suppl ementa ry charge r equired(Carry ou t supplem entary ch arge befo re use if 100% capacit y is require d.)

Supple mentar y charge re quired be fore use. Option al chargi ng way as be low:1.Charg ed for abov e 3 days at limt ed curren t 0.25CA and c onstan t volatge 2. 25V/ce ll.2.Charg ed for abov e 20hour s at limted cu rrent 0.25 CA and cons tant vola tge 2.45V /cell.3.Charg ed for 8~10 hours at lim ted curre nt 0.05CA .

Supple mentar y charge m ay often fai l to recover t he capac ity.The batte ry should n ever be lef t standin g till this is rea ched.

A

B

C