Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
1Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United KingdomTel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected]
www.ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Dimensions
Physical Specification
Specifications
Part Number:
Length:
Width:
Container Height:
Total Height (with terminal):
Approx Weight:
Terminal Type
Container Material
Rated Capacity
Max Discharge CurrentInternal ResistanceDischarge Characteristics
Design Floating Life at 20°CSelf Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For higher
temperatures the time interval will be shorter.
ISO9001
±
±
±
±
mm
mm
mm
mm
(
(
(
(
)
)
)
)
inches
inches
inches
inches
Normal Voltage
Normal Capacity (20HR)
Standard Terminal
Optional Terminal
Standard Option
Flame Retardant Option (FR)
Operating Temp. Range
Normal Operating Temp. Range
Cycle Use
Standby Use
Capacity affected by Temperature
Discharge:
Charge:
Storage:
Inital Charging Current less than
ABS
ABS (UL94:VO)
(20hr,1.80V/cell, 25°C / 77°F)
(10hr,1.80V/cell, 25°C / 77°F)
(5hr,1.75V/cell, 25°C / 77°F)
(3hr,1.75V/cell, 25°C / 77°F)
(1hr,1.60V/cell, 25°C / 77°F)
No limit on Initial Charging Current Voltage
Temp. Coefficient
Temp. Coefficient
Voltage
Approx kgkg ( lbs)
12V 9AH
F1 Terminal
10 Years
14.4V ~ 15.0V at 25°C(77°F) -30mV/°C
13.5V ~ 13.8V at 25°C(77°F) -20mV/°C
40°C (104°F) 103%
25°C (77°F) 100%
0°C (32°F) 86%
2.70A
12V
9AH
F1
F2
9.00 AH/0.450A
8.31 AH/0.831A
7.55 AH/1.51A
6.84 AH/2.28A
6.24 AH/6.24A
135A (5s)
Approx 17mΩ
5.862.66
5.95
2.56
3.70
3.92
1
1
1
1
151
65
94
99.5
UHR 9-12
UHR 9-12
High Rated
UHR 9-12
-15 ~ 50°C (5 ~ 122°F)
0 ~ 40°C (5 ~ 104°F)
-15 ~ 40°C (5 ~ 104°F)
25 ± 3°C (77 ± 5°F)
2
Constant Current Discharge (Amperes) at 25°C (77°F)
Constant Power Discharge (Watts) at 25°C (77°F)
Discharge Characteristics Float Charging Characteristics
Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life
Self Discharge Characteristics
Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United KingdomTel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected]
www.ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
ISO9001
La construcción de la batería será tipo AGM con ABS case (celda cerrada en la que se encuentran las placas de plomo, separador y electrolito contenidos. Se compone normalmente de célula y cubierta que están permanentemente unidas)
0 4 8 12 16 20 24 28 32 36
2.0
2.1
2.2
2.3
2.4
(V /cell)(A)
0.02C
0C
0.04C
0.06C
0.08C
0.10C
%
20
40
60
80
100
120
C hargeVolume
C harging C urrent
C harging Voltage
After 5 0% D ischarge
After 1 00% D ischarge
C harge V oltage(C onstant 2.2 5V /cell)
C harged V olume
C harging C urrent
00.1C A-2.25V /cell temperature25C
C harging Time(Hours)
0.05C
2 0 C.
120
100
80
60
40
20
0-20 -10 0 1 0 20 3 0 4 0 50
Cap
acity
(%)
Tempe rature( )0C
0.17C
1.0 C
Batte ry temperature
2068
0C3086
40104
50122 OF
0
2
3
5
810
12
Charging vol tage :2.25V/cell
0.05C
1 2 4 6 810 20 40 60 2 4 6 8 10 20 40 60 2 4 6 8 10 20
8.0
9.0
10.0
11.0
12.0
13.0
0.092 C0.17C
0.4C0.66C1.3C
2.2C
4C5C7C10C
S min H
Discharge Time
12V BatteryV
0Te mpera ture:25C
4.0
4.5
5.0
5.5
6.0
6.5
6V BatteryV
Term
inal
Vol
tage
(V)
1.8 5V /ce ll
1.8 0V /ce ll
1.7 5V /ce ll
1.7 0V /ce ll
1.6 7V /ce ll
1.6 0V /ce ll
5m in 10 m in 15 m in 30 m in 45 m in 1h 2h 3h 4h 5h 6h 8h 10 h 20 h20 m inF.V/ Tim e
30.8 21.5 16.1 13.1 10.1 7.24 5.65 3.12 2.19 1.72 1.44 1.25 0.98 0.812 0.446
34.3 23.2 17.1 13.9 10.5 7.42 5.80 3.18 2.23 1.76 1.47 1.28 1.00 0.831 0.450
37.9 24.8 18.0 14.5 10.8 7.61 5.93 3.24 2.28 1.80 1.51 1.30 1.03 0.843 0.455
41.7 26.3 18.6 15.0 11.1 7.77 6.02 3.30 2.32 1.83 1.54 1.33 1.05 0.858 0.463
43.9 27.4 19.4 15.6 11.3 7.95 6.13 3.35 2.36 1.87 1.57 1.36 1.06 0.874 0.469
46.3 28.5 20.2 16.3 11.7 8.08 6.24 3.40 2.40 1.91 1.60 1.39 1.08 0.887 0.472
5m in 10 m in 15 m in 30 m in 45 m in 1h 2h 3h 4h 5h 6h 8h 10 h 20 h20 m inF.V/ Tim e
1.8 5V /ce ll
1.8 0V /ce ll
1.7 5V /ce ll
1.7 0V /ce ll
1.6 7V /ce ll
1.6 0V /ce ll
57.5 40.3 30.2 24.7 19.2 13.9 10.9 6.05 4.27 3.36 2.83 2.45 1.93 1.61 0.883
62.0 42.6 31.6 26.0 19.8 14.1 11.1 6.13 4.32 3.42 2.87 2.50 1.98 1.64 0.890
67.8 45.0 33.0 26.9 20.2 14.4 11.3 6.22 4.39 3.49 2.93 2.54 2.01 1.66 0.898
73.6 47.1 33.7 27.7 20.7 14.6 11.5 6.32 4.47 3.55 2.98 2.59 2.05 1.69 0.913
76.4 48.3 34.8 28.5 21.0 14.9 11.6 6.40 4.54 3.59 3.04 2.64 2.08 1.72 0.925
79.2 49.6 35.6 29.2 21.3 15.0 11.7 6.46 4.59 3.66 3.09 2.69 2.11 1.74 0.929
S torage T ime(Months)
Rem
aini
ng C
apac
ity(%
)
8 10 120
4 6
60
80
100
0 2
20
40
025 C030 C
040 C
010 C A
B
C
No suppl ementa ry charge r equired(Carry ou t supplem entary ch arge befo re use if 100% capacit y is require d.)
Supple mentar y charge re quired be fore use. Option al chargi ng way as be low:1.Charg ed for abov e 3 days at limt ed curren t 0.25CA and c onstan t volatge 2. 25V/ce ll.2.Charg ed for abov e 20hour s at limted cu rrent 0.25 CA and cons tant vola tge 2.45V /cell.3.Charg ed for 8~10 hours at lim ted curre nt 0.05CA .
Supple mentar y charge m ay often fai l to recover t he capac ity.The batte ry should n ever be lef t standin g till this is rea ched.
A
B
C