    ENGINEERING DOCUMENT

    757-4002-140 CAD# D8538

    Subject: Hardware Installation Procedure

    for Ultinet Networking Option.

    Responsible Reviewed/Approved

    Originator Date Mgr. Control Systems Engineering Date

  • 8/16/2019 Ulti Net Install Procedure

    2/6

    Network Card Installation, Ultinet 757-4002-140 Page 2 

    RECORD OF CHANGES

    Engineering Document 757-4002-140 CAD # D8538

    Revision ECN # Revision Description Rev By Date Appd By Date

    A 14080 Original Release

    B 14142 Change Comm Panel Part Number SAW 11/97

    C 14168 Add Plug and Play Disabling Instructions SAW 01/98

  • 8/16/2019 Ulti Net Install Procedure

    3/6

    Network Card Installation, Ultinet 757-4002-140 Page 3 

    I. INTENT 

    To provide a standardized method to retrofit and install the Ultinet Network Option, including the

    Network Card, the Cabling, and the Comm Panel.

    II. APPLICABILITY 

     As required on all machines equipped with V2.0 or greater software, Pentium based motherboard

    and CPU.

    III. REFERENCE DOCUMENTS 

    1) 007-3002-001, Assy, ISA/P Card Cage.

    2) 802-2901-002, Cabinet, Knee Mill Control.

    IV. INDEX 

    Page 3 Kit DefinitionPage 4 ISA Network card installation instructions

    Page 4 BMC comm panel installation Instructions

    Page 5 Knee Mill network connector installation Instruction

    Page 6 Plug and Play disabling

    V. KIT DEFINITION 

    Ultinet Hardware and Cabling. (007-0020-001)

    Description Part Number Quantity

    PCB Assy, Etherlink III Network Card 415-0600-004T 1

    Connector, BNC -Y Type 406-0804-049 1

    Cable, Cat-4 w/RJ-45 Connectors 406-1663-001 1

    Cable, Coax w/BNC Connectors 406-1663-002 2

    Connector, RJ-45 Bulkhead 406-0804-047 1

    3mm Hex Nut 117-5009-001 2

    3 X 6mm Screw 108-5001-001 2

    3mm Washer 110-0066-004 2

    Connector, BNC Double Female 406-0804-048 2

    Panel, Comm Port w/Network Option 802-2700-022 1

    VI. SPECIAL TOOLS NEEDED 

     AT Keyboard with Extension Cable. 

  • 8/16/2019 Ulti Net Install Procedure

    4/6

    Network Card Installation, Ultinet 757-4002-140 Page 4 

    VII. INSTALLATION PROCEDURE 

    ISA NETWORK CARD INSTALLATION

    1. Be sure machine is running properly before beginning.

    2. Cycle the Machine Power Off.

    3. Locate the ISA Card Rack and remove cover.

    4. Locate an open ISA slot amongst the existing cards. (should be an open slot near canbus controller)

    5. Remove ISA blank bracket from the slot, and discard, retain mounting screw for use on Network Card

    Installation.

    6. Install Network card (415-0600-004T) in the chosen slot.

    7. Fasten with mounting screw from step 5.

    8. Replace cover on ISA Rack.

    9. Locate two black coax cables (406-1663-002).

    10. Locate BNC Y-type connector (406-0804-049).

    11. The BNC connector has a “board side” with one connection point, and a “cable side” with two

    connection points.

    12. Attach one end of each of the two coax cables, to each of the connection points on the cable side of

    the BNC connector.

    13. Connect the board side of the connector to the matching BNC connection point on the newly installedNetwork Card.

    14. Locate the cable with RJ-45 connectors, telephone type (406-1663-001)

    15. Install one end of the cable into the telephone jack on the newly installed Network Card.

    BMC COMM PANEL INSTALLATION

    16. Locate the comm panel mounted in the left-side door of the main electrical cabinet.

    17. Remove the components from the existing comm panel and set aside, retain all mounting screws,

    they will be used to reinstall components on new panel:

    The two DB-9 comm port connectors (PORT 1 and PORT2)

    The hour meter, indexer connector, and the light switch (if applicable)

    18. Remove the existing comm panel and discard, retain the mounting screws, they will be used to mount

    the new comm panel.

    19. Install the BNC connectors (406-0804-048) in the new panel where it’s labeled coax in and out.

    20. Install the RJ-45 connector (406-0804-047) in the new comm panel where it’s labeled 10 Base-T.

    Use the 3mm screws, washers, and nuts provided in this kit.

    21. Install the new comm panel. Refer to (802-2700-022) for proper orientation, and secure with screws

    from step 18.

    22. Install all components that were removed in step 17. Refer to (802-2700-022) for proper location.

    23. Use button plug (408-8001-027) for light switch hole, if light switch is not present.

    24. Locate the existing comm cables and their routing from the ISA rack to the comm panel.

    25. Locate the three new cables that are attached to the new network card, keeping the cables together;route them with the existing Comm cables up to the comm panel.

    26. Connect the telephone type cable to the telephone type plug, and connect the coax cables to the BNC

    type connectors. (Either BNC cable can connect to either BNC connector)

    27. Cycle the Machine Power On.

    28. Verify machine operation.

    29. If Network Option does not operate correctly, verify that the “PLUG AND PLAY” function is disabled

    on the network card. (Refer to instructions on page 6.)

  • 8/16/2019 Ulti Net Install Procedure

    5/6

    Network Card Installation, Ultinet 757-4002-140 Page 5 

    KNEE MILL NETWORK CONNECTOR INSTALLATION

    30. Locate the comm ports (PORT 1and PORT 2) on the side of the main electrical cabinet. This is the

    area that the new network connectors will be installed.

    31. Drill or punch all of the holes for the BNC feed thru connectors (406-0804-048), and the RJ-45 feed

    thru connector (406-0804-047). Refer to (802-2901-002) Knee Mill Cabinet Drawing.

    32. Install the new network connectors.

    33. Locate the existing comm cables and their routing from the ISA rack to the comm ports.

    34. Locate the three new cables that are attached to the new network card, keeping the cables together;

    route them with the existing Comm cables up to the network connectors.

    35. Connect the telephone type cable to the telephone type plug, and connect the coax cables to the BNC

    type connectors. (Either BNC cable can connect to either BNC connector)

    36. Cycle the Machine Power On

    37. Verify machine operation.

    38. If Network Option does not operate correctly, verify that the “PLUG AND PLAY” function is disabled

    on the network card. (Refer to instructions on page 6.)

  • 8/16/2019 Ulti Net Install Procedure

    6/6

    Network Card Installation, Ultinet 757-4002-140 Page 6 

    VIII. PLUG AND PLAY DISABLING 

    1. If machine power is on, cycle power off.

    2. Insert a DOS bootable disk into the floppy drive

    3. Cycle the Machine Power On

    4. Remove the DOS disk and replace it with the 3COM EtherDisk.

    5. At the A: prompt, type “3C5X9CFG.EXE”, press ENTER

    6. A menu comes up and says Configure NIC. Press ENTER

    7. Press the TAB key 5 times to highlight the “NIC CONFIGURE” box.8. Press the DOWN ARROW key 6 times to highlight the “PLUG AND PLAY” field.

    9. Press the ENTER key, “DISABLE” should now be selected.

    10. Press ENTER again.

    11. Press TAB key 4 times to highlight the “OK” box on the lower menu bar.

    12. Press ENTER again. The following message will pop-up. “The specified configuration is now being

    saved to the NIC.”

    13. Press ESC, then press ENTER. This will exit the program.

    14. Cycle the Machine Power Off, then back On Again.

    15. Verify machine operation.

    Web Site: http://support.3com.com/infodeli/tools/nic/3c509/3c5096.1.htm  

    Download Disk # 2 Extract the file to a floppy disk to run program file 3C5X9CFG.EXE as listed in step

    5 above