Upload
hadung
View
222
Download
0
Embed Size (px)
Citation preview
Index
AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listed is approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.
© 2010, AmerCable Incorporated
36-311 Type W (Flat) 2/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
36-314 Type W (Flat) 4/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
36-320 Type G (Flat) 2/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
36-322 Type G-GC (Flat) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
36-431 Type W (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
36-432 Type W (Round) 4/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
36-442 Type G-GC (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . 14-15
36-503 Type SHD-GC (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . 16-17
36-504 Type SHD-PCG 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
36-505 Type SHD-CGC 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
36-506 Type SHD-CGC 5kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
36-510 Type SHD (Flat) 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25
36-515 Type SHD-GC 5kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27
Type SHD-GC (Round) 3/C 2300V . . . . . . . . . . . . . . . . . . . . . . 27
36-516 Type SHD-PCG 5kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29
36-601/602/604 Type MP-GC 3/C 5-15kV (EP/CPE) . . . . . . . . . . . . . . . . . . . . 30-31
36-621/622/624 Type MP-GC 3/C 5-15kV (XLP/PVC) . . . . . . . . . . . . . . . . . . . 32-33
36-202-018 Longwall Signal Cable 2-9/C 50 Volts . . . . . . . . . . . . . . . . . . . 34
36-202-118 Underground Lighting Cable 2-9/C 110 Volts . . . . . . . . . . . . . . 35
37-119 DLO 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37
36-501 VFD 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-39
Tiger Stripes – Reflective and Standard . . . . . . . . . . . . . . . 40-41
Jacket Materials - CPE, TPU and Orange XL/XLS . . . . . . . . . . . 42
Safety, Training and Education . . . . . . . . . . . . . . . . . . . . . . . . 43
Cable Assemblies and Refurbishing . . . . . . . . . . . . . . . . . . 44-45
El Dorado, Arkansas
Made in America
[email protected] www.amercable.com 1
®
Committed to Safer, More Productive MiningSince the electrification of mines,AmerCable’s core business has been powering mine equipment.Surface or underground – AmerCable has a cable productivity solution for you. Our innovatively engineered and manufactured Tiger® Brand cable lineis designed for your toughest conditions. As the leading producer of mining cables in North America,AmerCable is dedicated to producing:
� cables that last longer in harsh mining environments
� cables designed to help provide greater levels of safety and productivity
� lowest cable cost per ton!
Mining Cable Innovation� Designing insulating and jacketing materials that
are more flexible with greater resistance to abrasion and moisture
� Cable constructions that last longer providing reduced down time for increased production
� New product development that addresses environmental, safety and cost reduction issues specific to your mining application.
Operating Excellence� On-time delivery – best in
the cable industry� Standard lead-time of
8 to 10 weeks� Urgent response shipment
capability of 2 to 4 weeks� Strategically located inventories
throughout the major mining regions. � AmerCable is an ISO-9001 certified manufacturer
Hands-on Field SupportOur mine-experienced field application engineers are available 24/7 for on-site evaluation and solutions. Theyalso conduct education and training sessions that addresssafety, splicing and cable handling issues. See page 47 for more information.
Factory InstalledCable Assemblies
See pages 46-47 for more information.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96132
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-311
Type W Flat 2/CMold-cured Jacket • 600/2000 Volts
ApplicationFor use on D.C. off-track mining equipment.Especially designed for D.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
JacketMold-cured thermosetwith cable identification via permanent marking.Standard Jacket: Black
Also available:OrangeXL(Special Order)
See Pages 42 for details
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
D-shaped cross-section
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 3
®
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" Minor Dimension± 0.040" Major Dimension
SizeAWG
86421
1/02/04/0
36-311-008006004002001010020040
No. of Wiresper
Conductor133 7x19133 7x19259 7x37259 7x37259 7x37259 7x37329 7x47532 19x28
InsulationThickness
mils6060606080808080
NominalOutside
Dimensions in.
0.51 x 0.840.56 x 0.930.61 x 1.050.73 x 1.240.81 x 1.400.93 x 1.510.99 x 1.631.10 x 1.89
Approx.Weightlbs. per1,000 ft.
340440580850
1070131016002300
Ampacity 1
40°CAmbient Temp
7295
127167191217250328
Power Conductors
36-311 • Type W Flat 2/C • 600/2000 Volts
ShuttleCar
Primary UsageRecommendation
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96134
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-314
Type W Flat 4/CMold-cured Jacket • 600/2000 Volts
ApplicationFor use on A.C. off-track mining equipment.Especially designed for A.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-33 and B-172 .
Insulation90°C ethylene-propylenerubber (EPR). Color codedblack, white, red, green.
JacketMold-cured thermosetwith cable identification via permanent marking.Standard Jacket: Black
Also available:OrangeXL(Special Order)
See Pages 42 for details
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
Square and D-shaped cross-section
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 5
®
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.050" Minor Dimension± 0.080" Major Dimension
SizeAWG
6421
36-314-006004002001
No. of Wiresper
Conductor133 7x19259 7x37259 7x37259 7x37
InsulationThickness
mils60606060
NominalOutside
Dimensions in.
0.68 x 1.710.76 x 1.910.82 x 2.250.98 x 2.54
Approx.Weightlbs. per1,000 ft.
910122017202240
Ampacity 1
40°CAmbient
Temp7293
122143
Power Conductors
36-314 • Type W Flat 4/C • 600/2000 Volts
Pump
ShuttleCar
RoofBolter
Primary UsageRecommendation
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96136
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-320
Type G Flat 2/CMold-cured Jacket • 2000 Volts
ApplicationFor use on D.C. off-track mining equipment.Especially designed for D.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.Insulation
90°C ethylene-propylenerubber (EPR)
JacketMold-cured thermosetwith cable identification via permanent marking.
Also available:OrangeXL(Special Order)
See Pages 42 for details
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
Ground WireUni-directional lay flexible tinned copper
D-shaped cross-section
� Mine Safety & Health Administration 184-MSHA. All underground mining cables
� Pennsylvania Department of Environmental Protection P-184. All underground mining cables.
� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 7
®
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" Minor Dimension± 0.040" Major Dimension
SizeAWG
6421
1/02/0
SizeAWG
875432
36-320-006004002001010020
No. of Wiresper
Conductor133 7x19259 7x37259 7x37259 7x37259 7x37329 7x47
No. of Wiresper
Conductor270 6x45180 6x30168 6x28168 6x28204 6x34246 6x41
InsulationThickness
mils606060808080
NominalOutside
Dimensions in.
0.56 x 1.020.61 x 1.150.73 x 1.350.81 x 1.550.93 x 1.670.99 x 1.85
Approx.Weightlbs. per1,000 ft.
500660990
123015401870
Ampacity 1
40°CAmbient Temp
95127167191217250
Power Conductors Grounding Conductor
36-320 • Type G Flat 2/C • 2000 Volts
Primary UsageRecommendation
ShuttleCar
RoofBolter
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96138
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-322
Type G-GC Flat 3/CMold-cured Jacket • 2000 Volts
ApplicationFor use on A.C. off-track mining equipment.Especially designed for A.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.Insulation
90°C ethylene-propylenerubber (EPR)
JacketMold-cured thermosetwith cable identification via permanent marking.
Also available:OrangeXL(Special Order)
See Pages 42 for details
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
Ground WireUni-directional lay flexible tinned copperwith green covering
Ground Check WireUni-directional lay flexible tinned copperwith yellow insulation
Square and D-shaped cross-section
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 9
®
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.050" Minor Dimension± 0.080" Major Dimension
SizeAWG
6421
SizeAWG
8754
36-322-006004002001
No. of Wiresper
Conductor133 7x19259 7x37259 7x37259 7x37
No. of Wiresper
Conductor270 6x45180 6x30168 6x28168 6x28
InsulationThickness
mils60606080
NominalOutside
Dimensions in.
0.67 x 1.690.75 x 1.890.81 x 2.230.97 x 2.48
Approx.Weightlbs. per1,000 ft.
940124016902170
Ampacity 1
40°CAmbient
Temp79
104138161
Power Conductors Grounding Conductor
36-322 • Type G-GC Flat 3/C • 2000 Volts
Primary UsageRecommendation
Pump
ShuttleCar
RoofBolter
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961310
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-431
Type W Round 3/CMold-cured Jacket • 2000 Volts
ApplicationEspecially suitable for general use where baregrounding conductors are not required ordesired. Recommended maximum continuousconductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
Round-shaped cross-section
TapeNon-conducting
Photo courtesy Joy Mining Equipment
See Page 42 for jacket color options.
See Page 40-41 for Tiger Stripe options
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 11
®
36-431 • Type W Round 3/C • 2000 Volts
1 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request.
2 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" 8-1 AWG± 0.040" 1/0 - 2/0 AWG± 0.050" 3/0 - 4/0 AWG
SizeAWG
86421
1/02/03/04/0
36-431-008006004002001010020030040
No. of Wiresper
Conductor133133259259259266323418532
InsulationThickness
mils606060608080808080
NominalOutside
Dimensions in.
0.911.011.171.341.511.651.751.892.04
Approx.Weightlbs. per1,000 ft.
550730
1020143018002140258029223800
Ampacity 2
40°CAmbient Temp
5979
104138161186215249287
Power Conductors
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961312
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-432
Type W Round 4/CMold-cured Jacket • 2000 Volts
ApplicationEspecially suitable for use with mobile miningequipment such as continuous miners, drills,cutters, loading machines and AC shuttle cars.Type W is for applications where bare grounding conductors are not required or desired.Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
Round-shaped cross-section
See Page 42 for jacket color options.
See Page 40-41 for Tiger Stripe options
TapeNon-conducting
PureIntegral Fill
for greatertorsion
resistance
PureIntegral Fill
Cable shown with optional Tiger Stripes. See page 46.Photo courtesy Joy Mining Equipment
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 13
®
36-432 • Type W Round 4/C • 2000 Volts
Primary UsageRecommendation
1 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request.
2 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" 8-1 AWG± 0.040" 1/0 - 2/0 AWG± 0.050" 3/0 - 4/0 AWG
SizeAWG
86421
1/02/03/04/0
36-432-008006004002001010020030040
No. of Wiresper
Conductor133133259259259266323418532
InsulationThickness
mils606060608080808080
NominalOutside
Dimensions in.
0.991.101.271.481.681.791.932.072.26
Approx.Weightlbs. per1,000 ft.
670890
1250180022702680320036274650
Ampacity 2
40°CAmbient Temp
547293
122143165192221255
Power Conductors
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
ContinuousMiner
ShuttleCar
Pump
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961314
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-442
Type G-GC Round 3/CMold-cured Jacket • 2000 Volts
ApplicationEspecially suitable for use with mobile miningequipment such as continuous miners, drills,cutters, loading machines, AC shuttle cars andpumps. Type G-GC is for applications wheregrounding conductors and a ground check conductor are required. Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184 MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanentmarking.
ConductorsFlexible tinned copper
Ground WiresFlexible tinned copper
Ground Check Conductor2
Flexible tinned copper with yellow polypropyleneinsulation
Round-shaped cross-section
Photo courtesy Joy Mining Equipment
PureIntegral Fill
for greatertorsion
resistance
PureIntegral Fill
TapeNon-conducting
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
PumpApplicationConstruction36-442 is available withinsulated grounds forpump applications thatrequire this specification.
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 15
®
1 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request.
2Ground Check Conductor – 10 AWG (minimum 49strand 7x7) ground check conductor on 8 AWGthrough 2 AWG cable.
8 AWG (minimum 133 strand 7x19) ground checkconductor on 1 AWG through 4/0 AWG cable.
6 AWG (minimum 133 strand 7x19) ground checkconductor on 250 kcmil and larger cable.
3 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" 8-1 AWG± 0.040" 1/0 - 2/0 AWG± 0.050" 3/0 - 4/0 AWG± 0.060" 250 - 500 kcmil
36-442 • Type G-GC Round 3/C • 2000 Volts
Primary UsageRecommendation
ContinuousMiner
ShuttleCar
RoofBolter
Pump
SizeAWG
86421
1/02/03/04/0250350500
SizeAWG101087654222
1/02/0
No. of Wiresper
Conductor133259259259259266323418532627888
1221
No. of Wiresper
Conductor4949
133133133133259259259259266323
InsulationThickness
mils606060608080808080959595
NominalOutside
Dimensions in.
0.971.051.191.341.511.651.751.892.042.392.683.03
Approx.Weightlbs. per1,000 ft.
600750
1070148018902340275033773980500067508900
Ampacity 3
40°CAmbient Temp
5979
104138161186215249287320394487
Power Conductors Grounding Conductors
36-442-008006004002001010020030040250350500
Number of MultiplyingLayers Correction Factors
1 0.852 0.653 0.454 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961316
36-503
Type SHD-GCMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable for use in circuits not exceeding 2,000 volts. Designedfor applications such as longwall shearers,continuous miners, loaders, drills, conveyors,pumps and mobile equipment where groundingconductors, a ground check conductor andmetallic shielding are required. Recommended maximum continuous conductor temperatureis 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket3
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)
Ground WiresFlexible tinned copper
Ground Check Conductor2
Flexible tinned copperwith yellow polypropyleneinsulation
Round-shaped cross-section
InsulationShieldingTinned copperand color codednylon braid
Separator Tape
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
PureIntegral Fill
for greatertorsion
resistance
PureIntegral Fill
Photo courtesy Joy Mining Equipment
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 17
®
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-503 • Type SHD-GC 3/C • 2000 Volts
Primary UsageRecommendation
ContinuousMiner
Longwall Miner
Pump
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
2Ground Check Conductor – 10 AWG (minimum 49 strand 7x7) ground check conductor on 8 AWG through 2 AWG cable.
8 AWG (minimum 133 strand 7x19) ground check conductor on 1 AWG through 4/0 AWG cable.
6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.
3 Jacket – Extra-Heavy-Duty (EHD) CPE jacket. Black is standard. Colored EHD CPE jackets available upon request. See page 42.
Tolerances – ± 5% of nominal outside diameter
SizeAWG
6421
1/02/03/04/0250350500
SizeAWG108654321
1/02/04/0
No. of Wiresper
Conductor133259259259266323418532627888
1221
No. of Wiresper
Conductor49
133133133259259259259266323532
InsulationThickness
mils7070708080808080959595
NominalOutside
Dimensions in.
1.291.401.591.761.862.002.132.312.512.813.19
Jacket Thickness
mils155155170190190205205220220235265
Approx.Weightlbs. per1,000 ft.
1160149020002450284034003680486059507400
10100
Ampacity 1
40°CAmbient Temp
93122159184211243279321355435536
Power Conductors Grounding Conductors
36-503-006004002001010020030040250350500
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
RoofBolter
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961318
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-504
Type SHD-PCG • LongwallMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable designed foruse on longwall shearers, where three shieldedpower conductors, three unshielded controlconductors, and a grounding conductor arerequired. Recommended maximum continuousconductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of EnvironmentalProtection and the Mine Safety and HealthAdministration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Ground ConductorFlexible tinned copper located in the center of the cable
Jacket2
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)Control Group 3 Conductors
Flexible tinned copperethylene polypropylene rubberinsulation color coded black,white, red and an overall thermosetting jacket
Round-shaped cross-section
Insulation ShieldingTinned copper and color-coded nylon braid
Separator TapeNon-conducting
See Page 42 for jacketcolor options.
PureIntegral Fill
for greatertorsion
resistance
PureIntegral Fill
Photo courtesy DBT America
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381.
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 19
®
36-504 • Type SHD-PCG Longwall • 2000 Volts
Primary UsageRecommendation
Longwall Miner
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
2 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
Tolerances – ± 5% of nominal outside diameter
SizeAWG2/03/04/0
SizeAWG
21
1/0
SizeAWG
886
No. of Wiresper
Conductor323418532
No. of Wiresper
Conductor246258426
No. of Wiresper
Conductor133133133
NominalOutside
Dimensions in.
2.232.322.67
Approx.Weightlbs. per1,000 ft.
351040754990
Ampacity 1
40°CAmbient Temp
243279321
Power Conductors Grounding Conductors Control Conductors
36-504-020030040
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961320
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-505
Type SHD-CGC 3/CMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable for use in circuitsnot exceeding 2,000 volts. Designed for applicationssuch as longwall shearers, continuous miners, loaders, drills, conveyors, pumps, and other mobileequipment requiring grounding conductors, where a ground check conductor, and metallic shieldingare required. Recommended maximum continuousconductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of Environmental Protectionand the Mine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceeds ICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosettingChlorinated Polyethylene(CPE) Jacket. Cableidentification via permanent marking.
ConductorsFlexible tinned copper
Insulation ShieldingTinned copper and color-coded nylon braid
Ground Check Conductor2
Flexible tinned copper withyellow insulation located inthe center of the cable
Round shaped cross-section
Ground WiresFlexible tinned copper
TapeNon-conductingSeparator TapeNon-conducting
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
PureIntegral Fill
for greatertorsion
resistance
PureIntegral Fill
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & ApprovalsPhoto courtesy Eickhoff
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 21
®
1 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
2Ground Check Conductor – 16 AWG tinned copperconductor, designed to withstand extreme flexingand be extensible, insulated with yellow polypropylene
3 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 5% of nominal outside diameter
36-505 • Type SHD-CGC 3/C • 2000 Volts
Primary UsageRecommendation
Longwall Miner
ContinuousMiner
SizeAWG2/03/04/0350
SizeAWG
5431
No. of Wiresper
Conductor323418532888
No. of Wiresper
Conductor133259259259
InsulationThickness
mils80808095
NominalOutside
Dimensions in.
2.092.212.362.81
Jacket Thickness
mils205205220250
Approx.Weightlbs. per1,000 ft.
3400393448607400
Ampacity 3
40°CAmbient Temp
243279321435
Power Conductors Grounding Conductors
36-505-020030040350
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961322
36-506
Type SHD-CGC 3/CMold-cured Jacket • 5000 Volts
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosettingChlorinated Polyethylene(CPE) Jacket. Cableidentification via permanent marking.
ConductorsFlexible tinned copper
Insulation ShieldingTinned copper and color-coded nylon braid
Ground Check Conductor2
Flexible tinned copper withyellow insulation located inthe center of the cable
Ground WiresFlexible tinned copper
Strand ShieldSemi-conductinglayer
ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding 5000 volts.Designed for applications such as longwall miners, continuous miners, conveyors, pumps,and other mobile equipment requiring groundingconductors, a ground check conductor, andmetallic shielding overall. Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Round-shaped cross-section
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
Photo courtesy Joy Mining Equipment
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 23
®
36-506 • Type SHD-CGC 3/C • 5000 Volts
Primary UsageRecommendation
Longwall Miner
ContinuousMiner
1 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
2Ground Check Conductor – 16 AWG tinned copper conductor, designed to withstand extreme flexing andbe extensible, insulated with yellow polypropylene.
3 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – +8%/-5% of nominal outside diameter
SizeAWG2/03/04/0350
SizeAWG
5431
No. of Wiresper
Conductor323418532888
No. of Wiresper
Conductor133259259259
InsulationThickness
mils110110110120
NominalOutside
Dimensions in.
2.2002.3602.5002.950
Jacket Thickness
mils220235235265
Approx.Weightlbs. per1,000 ft.
3716413051907571
Ampacity 3
40°CAmbient Temp
243279321435
Power Conductors Grounding Conductors
36-506-020030040350
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961324
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-510
Type SHD Flat 3/CMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable for use in circuits not exceeding 2,000 volts. Especiallydesigned for use on continuous miners requiringgrounding conductors and metallic shieldingover each conductor. Recommended maximumcontinuous conductor temperature is 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.Reinforcement
JacketMold-cured thermosetwith cable identification via permanent marking.
ConductorsFlexible tinned copper
Insulation90°C ethylene-propylenerubber (EPR)
Insulation ShieldingTinned copper and textile braid
Separator Tape
Cross-section
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
Ground WiresFlexible tinnedcopper coveredwith semi-conductivethermoset compound
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 25
®
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
Jacket – Extra-Heavy-Duty black neoprene is standard.
Tolerances – ± 0.050 inch minor dimension± 0.080 inch major dimension
SizeAWG2/0
SizeAWG
336-510-
020
No. of Wiresper
Conductor329 7x47
No. of Wiresper
Conductor204 6x34
InsulationThickness
mils80
NominalOutside
Dimensions in.
1.205 x 2.970
Approx.Weightlbs. per1,000 ft.
3600
Ampacity 1
40°CAmbient Temp
243
Power Conductors Grounding Conductors
36-510 • Type SHD Flat 3/C • 2000 Volts
Primary UsageRecommendation
ContinuousMiner
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961326
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-515
Type SHD-GC 3/CMold-cured Jacket • 5000 Volts
ApplicationHeavy duty portable power cable for use in circuits not exceeding 5,000 volts (see nextpage for continuous miner circuit requirementsexceeding 2000 volts). Designed for applica-tions such as longwall shearers, continuousminers and mobile equipment such as shovels,dredges and drills. Recommended maximumcontinuous conductor temperature is 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58.
Tiger® Brand Cable meets or exceeds ASTM B-172 and B-33.
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)
Ground WiresFlexible tinned copper
Strand ShieldSemi-conducting layer
Ground Check Conductor2
Flexible tinned copper with yellow polypropylene insulation
Round-shaped cross-section
InsulationShieldingTinned copperand color codednylon braid
Assembly Taped core
Separator Tape
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
Tiger ® Brand cables come in six colors for safe, easy circuit identification. See page 42 for details.
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 27
®
36-515 • Type SHD-GC 3/C • 5000 Volts
Primary UsageRecommendation
Longwall Miner
1 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
2Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 6 AWG through 4/0 AWG cable.
6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.
3 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – +8%/-5% of nominal outside diameter
SizeAWG
6421
1/02/03/04/0250350500
SizeAWG108654321
1/02/04/0
No. of Wiresper
Conductor133259259259266323418532627888
1221
No. of Wiresper
Conductor49
133133133259259259259266323532
InsulationThickness
mils110110110110110110110110120120120
NominalOutside
Dimensions in.
1.561.681.871.952.082.202.362.502.692.953.31
Jacket Thickness
mils185185205205220220235235250265280
Approx.Weightlbs. per1,000 ft.
1560192025002860339038304418530064507880
10440
Ampacity 3
40°CAmbient Temp
93122159184211243279321355435536
Power Conductors Grounding Conductors
36-515-006004002001010020030040250350500
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
ContinuousMiner
2300VContinuous MinerApplicationsHeavy duty orange/green jacketed portablepower cable for use in continuous miner circuits exceeding 2,000 volts.
Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58.
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961328
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-516
Type SHD-PCG • LongwallMold-cured Jacket • 5000 Volts
ApplicationHeavy duty portable power cable designed foruse on longwall shearers, where three shieldedpower conductors, three unshielded controlconductors, and a grounding conductor arerequired. Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Ground ConductorFlexible tinned copper located in the center of the cable
Jacket2
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)Control Group 3 Conductors
Flexible tinned copperethylene polypropylene rubberinsulation color coded black,white, red and an overall thermosetting jacket
Round-shaped cross-section
Strand ShieldSemi-conductinglayer
Insulation ShieldingTinned copper and color-coded nylon braid
Separator TapeNon-conducting
See Page 42 for jacketcolor options.
PureIntegral Fill
for greatertorsion
resistance
PureIntegral Fill
Photo courtesy 20 Mile Coal Mine
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381.
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 29
®
36-516 • Type SHD-PCG 3/C • 5000 Volts
Primary UsageRecommendation
Longwall Miner
1 Ampacity – Based on continuous duty at 90°C conductor temperature.
2 Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
Tolerances – +8%-5% of nominal outside diameter
SizeAWG
21/02/03/04/0
SizeAWG
4321
1/0
SizeAWG
88886
No. of Wiresper
Conductor259266323418532
No. of Wiresper
Conductor168222246259426
No. of Wiresper
Conductor133133133133133
NominalOutside
Dimensions in.
2.032.272.452.582.76
Approx.Weightlbs. per1,000 ft.
27693571377447526030
Ampacity 1
40°CAmbient Temp
159211243279321
36-516-002010020030040
Power Conductors Grounding Conductors Control Conductors
Nearest StandardMetric Cond.
mm2
0.500.501.001.502.50
46
1016253550507095
120120150185240240300400400500
Area ofAWG/kcmil
in mm2
0.350.520.821.312.083.315.268.37
13.3021.1533.6242.4153.4967.4385.01107.2126.7152.0177.3202.7253.4304.0380.0405.4506.7
AWG/kcmilSize
2220181614121086421
1/02/03/04/0250300350400500600750800
1000
AWG/Metric Cross Reference
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961330
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-601/602/604
Type MP-GC 3/C • Mine Power Feeder • 5/8/15kVMold-cured Jacket • 100% Level (Grounded)
ApplicationConnections between units of mine distributionsystems not exceeding the rated voltage wheninstalled in duct, conduit or open air and for direct burial in wet and dry locations.Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-8 and B-33.
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsCopper
Insulation90°C ethylene-propylenerubber (EPR)Ground WiresTinned copper
Strand ShieldSemi-conducting layer
Ground Check Conductor8 AWG 7-wire copper with yellow polypropylene insulation
Round-shaped cross-section
InsulationShieldingSemi-conductinglayer undercopper tape(phase identification provided)
Assembly Taped core
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
See Page 42 for jacketcolor options.
Cable may be suspendedvertically by using a
messenger and specialmechanical connectors.
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 31
®
5000 Volts • 36-601 • Type MP-GC 3/C
8000 Volts • 36-602 • Type MP-GC 3/C
15000 Volts • 36-604 • Type MP-GC 3/C
Primary UsageRecommendation
1 Jacket – CPE jacket. Black is standard. Colored CPE jackets available upon request. See page 42.
2 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – + 8%/-5% of nominal outside diameter
SizeAWG
421
1/02/04/0250350500
SizeAWG
865431
1/02/04/0
No. of Wiresper
Conductor7719191919373737
No. of Wiresper
Conductor77777
19191919
InsulationThickness
mils909090909090909090
NominalOutside
Dimensions in.
1.421.561.651.761.882.142.232.472.70
Jacket Thickness
mils110110110110110140140140140
Approx.Weightlbs. per1,000 ft.
144118272168260230104190482560628427
Ampacity 2
40°CAmbient Temp
122159184211243321355435536
Power Conductors Grounding Conductors
36-601-004002001010020040250350500
SizeAWG
421
1/02/04/0250350500
SizeAWG
865431
1/02/04/0
No. of Wiresper
Conductor7719191919373737
No. of Wiresper
Conductor77777
19191919
InsulationThickness
mils115115115115115115115115115
NominalOutside
Dimensions in.
1.541.661.781.892.032.282.312.582.88
Jacket Thickness
mils110110110110110140140140140
Approx.Weightlbs. per1,000 ft.
160819192507266032574382496564848857
Ampacity 2
40°CAmbient Temp
122159184211243321355435536
Power Conductors Grounding Conductors
36-602-004002001010020040250350500
SizeAWG
21
1/02/04/0250350500
SizeAWG
65431
1/02/04/0
No. of Wiresper
Conductor719191919373737
No. of Wiresper
Conductor7777
19191919
InsulationThickness
mils175175175175175175175175
NominalOutside
Dimensions in.
1.982.112.182.302.542.612.803.15
Jacket Thickness
mils110110110110140140140170
Approx.Weightlbs. per1,000 ft.
25173023329636795146561870559405
Ampacity 2
40°CAmbient Temp
164187215246325359438536
Power Conductors Grounding Conductors
36-604-002001010020040250350500
Mine Power Feeder
Vertical
Mine Power Feeder
Horizontal
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961332
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-621/622/624
Type MP-GC 3/C • Mine Power FeederPVC Jacket • 100% Level (Grounded)
ApplicationConnections between units of mine distributionsystems not exceeding the rated voltage wheninstalled in duct, conduit or open air. For directburial in wet and dry locations. Recommendedmaximum continuous conductor temperatureis 90°C.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-8 and B-33.
Jacket1
Polyvinyl chloride (PVC),cable identification via permanent surface marking.
ConductorsCopper
Insulation90°C cross-linked polyethylene
Strand ShieldSemi-conducting layer
Ground Check Conductor8 AWG 7-wire copper with yellow polypropylene insulation
Round-shaped cross-section
InsulationShieldingSemi-conductinglayer undercopper tape(phase identification provided)Fillers
Assembly Taped core
Ground WiresTinned Copper
Binder Tape
PVC jacket color optionsare the same as CPE. See Page 42
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.1
� Canadian Standards Association File 82346, FT1, FT5, -35°C Type MP-GC, MPF up to 25kV
Ratings & Approvals
Cable may be suspendedvertically by using amessenger and specialmechanical connectors.
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 33
®
5000 Volts • 36-621 • Type MP-GC 3/C
8000 Volts • 36-622 • Type MP-GC 3/C
15000 Volts • 36-624 • Type MP-GC 3/C
Primary UsageRecommendation
1 Jacket – PVC2 Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – + 8%/-5% of nominal outside diameter
SizeAWG
421
1/02/04/0250350500
SizeAWG
865431
1/02/04/0
No. of Wiresper
Conductor7719191919373737
No. of Wiresper
Conductor77777
19191919
InsulationThickness
mils909090909090909090
NominalOutside
Dimensions in.
1.421.561.651.761.882.142.232.472.70
Jacket Thickness
mils110110110110110140140140140
Approx.Weightlbs. per1,000 ft.
122416531950220027213845432156527721
Ampacity 2
40°CAmbient Temp
122159184211243321355435536
Power Conductors Grounding Conductors
36-621-004002001010020040250350500
SizeAWG
421
1/02/04/0250350500
SizeAWG
865431
1/02/04/0
No. of Wiresper
Conductor7719191919373737
No. of Wiresper
Conductor77777
19191919
InsulationThickness
mils115115115115115115115115115
NominalOutside
Dimensions in.
1.541.661.781.892.032.282.312.582.88
Jacket Thickness
mils110110110140140140140140140
Approx.Weightlbs. per1,000 ft.
136617272174265628953983448458277893
Ampacity 2
40°CAmbient Temp
122159184211243321355435536
Power Conductors Grounding Conductors
36-622-004002001010020040250350500
SizeAWG
21
1/02/04/0250350500
SizeAWG
65431
1/02/04/0
No. of Wiresper
Conductor719191919373737
No. of Wiresper
Conductor7777
19191919
InsulationThickness
mils175175175175175175175175
NominalOutside
Dimensions in.
1.982.112.182.302.542.612.803.15
Jacket Thickness
mils140140140140140140140170
Approx.Weightlbs. per1,000 ft.
20212503265830664369487564128610
Ampacity 2
40°CAmbient Temp
164187215246325359438536
Power Conductors Grounding Conductors
36-624-002001010020040250350500
Mine Power Feeder
Horizontal
Mine PowerFeederVertical
Note:Cable maybe suspendedvertically byusing amessengerand specialmechanicalconnectors.
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961334
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-202-018
Longwall Signal Cable2-9 Conductors • 50 Volts
ApplicationA flexible signal cable for use in Longwall and other underground mining applications. The TPU jacket providesextra-tough physical characteristics needed in the mining environment. Cable is available with full copper braid shielding upon request.
JacketThermoplastic Polyurethane(TPU)
Power ConductorsExtra flexible stranded per ASTM B-174
Round-shaped cross-section
InsulationChemically cross-linked, non-chlorinated thermosetting, flame retardant polyolefin
� 90°C Temperature Rating
� Tiger® Brand Mining Cables materials meetor exceed industry specifications
� Mine Safety and Health Administration184-MSHA
� Pennsylvania Department of EnvironmentalProtection P-184
Ratings & Approvals
Colors Available:Black (standard)Orange (optional)
Tolerances – ± 5% of nominal outside diameter
SizeAWG181818181818181816161616161616161414141414141414
Number of
Conductors234567892345678923456789
PartNumber
36-202-018203-018204-018205-018206-018207-018208-018209-018202-016203-016204-016205-016206-016207-016208-016209-016202-014203-014204-014205-014206-014207-014208-014209-014
DiameterOver
Insulation (Inches)
0.1150.1150.1150.1150.1150.1150.1150.1150.1250.1250.1250.1250.1250.1250.1250.1250.1400.1400.1400.1400.1400.1400.1400.140
OverallDiameter(Inches)
0.4400.4600.4900.5200.5600.5600.6300.6600.4600.4800.5100.5500.5900.5900.6600.6900.4900.5100.5500.5900.6300.6300.7100.750
Weight(lbs./ft.)0.0870.1000.1170.1360.1560.1630.1970.2150.0990.1140.1330.1580.1830.1900.2250.2470.1180.1380.1660.1960.2250.2380.2780.300
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 35
®
36-202-118
Underground Lighting Cable2-9 Conductors • 110 Volts
ApplicationA flexible insulated cable for use in longwall and other minelighting systems. The TPU jacket provides extra-tough physicalcharacteristics needed in the underground mining environment.Cable is available with full copper braid shielding upon request.
JacketThermoplastic Polyurethane(TPU)
Power ConductorsExtra flexible stranded per ASTM B-174
Round-shaped cross-section
InsulationChemically cross-linked, non-chlorinated thermosetting, flame retardant polyolefin
� 90°C Temperature Rating
� Tiger® Brand Mining Cables materials meet or exceed industry specifications
Ratings
Colors Available:Black (standard)Orange (optional)
Tolerances – ± 5% of nominal outside diameter
SizeAWG18181818181818181616161616161616141414141414141412121212121212121010101010101010
Number of
Conductors2345678923456789234567892345678923456789
PartNumber
36-202-118203-118204-118205-118206-118207-118208-118209-118202-116203-116204-116205-116206-116207-116208-116209-116202-114203-114204-114205-114206-114207-114208-114209-114202-112203-112204-112205-112206-112207-112208-112209-112202-110203-110204-110205-110206-110207-110208-110209-110
DiameterOver
Insulation (Inches)
0.1150.1150.1150.1150.1150.1150.1150.1150.1250.1250.1250.1250.1250.1250.1250.1250.1400.1400.1400.1400.1400.1400.1400.1400.1600.1600.1600.1600.1600.1600.1600.1600.1800.1800.1800.1800.1800.1800.1800.180
OverallDiameter(Inches)
0.4400.4600.4880.5200.5600.5600.6400.6600.4600.4800.5120.5500.5900.5900.6700.6900.4900.5100.5500.5880.6300.6300.7200.7550.5260.5550.5960.6420.6900.6900.7700.8150.5700.5980.6450.6980.7500.7500.8350.875
Weight(lbs./ft.)0.0870.1000.1160.1350.1560.1630.1980.2150.1060.1140.1340.1580.1830.1910.2250.2470.1190.1380.1660.1950.2250.2380.2780.3020.1480.1770.2130.2540.2970.3160.3880.4260.1860.2260.2760.3310.4010.4620.5190.626
Photo courtesy 20 Mile Coal Mine
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961336
37-119
Flexible Power Cable • DLOEP/CPE • RHH, RHW-2 • 2000 Volts
ApplicationAmerCable’s 2000V Diesel Locomotive Cable (DLO) is a singleconductor portable power cable suitable for use in applicationsneeding great flexibility, excellent wearability and good flex life.Applications include motor and generator leads, battery leads,shipyards, telecommunications power, heavy earth movingequipment, and renewable energy applications.
Features� A two layer composite of flame retardant, oil and sunlight
resistant Chlorinated Polyethylene (CPE) outer layer andEthylene-Propylene rubber (EPR) inner layer. Compositedesign provides significant diameter reductions compared todesigns using full thickness jackets.
� Suitable for continuous operating temperatures of 90°C, wet or dry
� Rated RHH, RHW-2; 2/0 – 1111 kcmil listed and marked “for CT use”
� UL listed as Sunlight Resistant
� UL listed as Marine Shipboard Cable (4/0 and larger) Special order only
� Insulation and jacket meet hazardous waste regulations, perCode of Federal Regulations 40 Section 261 (40CFR261) forcharacteristic lead content
� Flame Resistance: FT-4/IEEE1202 for 2/0 1111 kcmil and UL VW-1
� Meets smoke release and other requirements of VerticalCable Tray Test UL 1685 and is marked “ST-1” for 2/0 – 1111 kcmil
JacketFlame retardant, oil and sunlight retardant Chlorinated Polyethylene (CPE)
See Page 34for jacketcolor options.
Round-shaped cross-section
Ratings & Approvals
InsulationEthylene-Propylene rubber (EPR)
ConductorFlexible-stranded, tin-coated annealedcopper
SSeparatorSuitable separator tape provides easy stripping of insulation
Extremely flexible strandingfor increased overall cable
flexibility and ease of installation
� UL Standard 44: Thermoset Insulated Wires &Cables, Types RHH, RHW-2. UL VW-1.
� UL Standard 1685: Vertical Tray Fire propagation and Smoke Release Test forElectrical and optical Fiber Cables. (UL, LS)
� AAR 591 Wire and Cable Insulating Material:Strand Construction except 3/0 and 4/0.
� ASTM B-33: Standard Specification for TinnedSoft or Annealed Copper Wire for ElectricalPurposes.
� ASTM B-172: Standard Specification for Rope-Lay-Stranded Copper Conductors havingBunch-Stranded Members, for ElectricalConductors.
� MSHA P-184
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 37
®
* Ampacity – Calculated with at 90°C conductor temperature and 30°C ambient air, per2002 NEC, Table 310-17
• Cable diameters are subject to +/-5% manufacturingtolerance
• Sizes above 1000 kcmil are not UL listed
37-119 • Portable Power Cable • 2000 Volts
201 14 19 0.045 0.015 0.214 31 35202 12 19 0.045 0.015 0.233 41 40203 10 27 0.045 0.015 0.257 58 55204 8 37 0.055 0.030 0.326 86 80205 6 61 0.055 0.030 0.365 124 105207 4 105 0.055 0.030 0.460 198 140209 2 147 0.055 0.030 0.498 261 190210 1 224 0.065 0.045 0.618 400 220211 1/0 266 0.065 0.045 0.664 468 260212 2/0 323 0.065 0.045 0.704 561 300213 3/0 418 0.065 0.045 0.789 725 350214 4/0 532 0.065 0.045 0.839 888 405215 262 646 0.075 0.065 0.973 1048 467216 313 777 0.075 0.065 1.029 1227 522217 373 925 0.075 0.065 1.094 1436 591218 444 1110 0.075 0.065 1.169 1691 652219 535 1332 0.090 0.065 1.295 2034 728220 646 1591 0.090 0.065 1.368 2395 815221 777 1924 0.090 0.065 1.488 2837 904222 929 2318 0.090 0.065 1.583 3448 1005223 1111 2745 0.130 0.065 1.707 4156 1119
Approx.Weightlbs. per1,000 ft.
*Ampacity90°C
Part No.37-119-
SizeAWG/kcmil
MinimumWires perConductor
NominalInsulationThickness
in.
NominalJacket
Thickness in.
NominalOutside
Diameter in.
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961338
36-501
VFD Power Cable • Shielded • 2000 Volts3 Conductors + 3 Grounds + Ground Check(s)
ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable materials meet orexceed ICEA Standard S-75-381/NEMA WC-58for Type SHC constructions. ASTM B-172 andB-33.
Ratings & Approvals� 90˚C Temperature Rating� Tiger® Brand Mining Cable materials
meet or exceed ICEA Standard S-75-381/NEMA WC-58.
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Canadian Standards Association (pending)File 82346CSA Phase Color ID available on MTO
JacketReinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
See Page 34 for jacket color options.
Ground Conductors (x3)Flexible tinned rope stranded conductors perASTMB-172 and B-33,Insulated and colored green
Ground CheckWire(s)Flexible tinnedcopper with yellow insulation.Center groundcheck available
ShieldOverall tinned copper braid plus aluminum/polyester tape providing100% coverage
InsulationType II EPDM (EPR) suitablefor continuous operation at90°C. Ozone resistant.
Round-shaped cross-section
Power ConductorExtra flexibletinned ropestranded conductors perASTM-172 and B-33
*Cable diameters are subject to a +/- 5% manufacturing tolerance1Ground Check Conductor – #16 AWG extensible strand for center groundcheck.
#14 AWG is the minimum size for non-center ground check wires2Ampacity Ratings – based on continuous duty at 90°C conductor temperature
002 2 8 0.155 1.43 1790 159001 1 7 0.170 1.64 2150 184010 1/0 6 0.170 1.74 2550 211020 2/0 5 0.190 1.89 3100 243030 3/0 4 0.190 2.01 4050 279040 4/0 3 0.220 2.17 4390 321250 250 3 0.220 2.40 5950 355350 350 1 0.220 2.68 7840 405500 500 1 0.265 3.03 9730 536
Part No.36-501
PowerConductor
SizeAWG/kcmil
NNoommiinnaallJacket
Thicknessin.
GroundingConductorsSize AWG1
NominalDiameter
in.
Approx.Weightlbs./ft.
Ampacity2
90°C
CorrectionFactorsFor ampacities for various ambienttemperatures above or below 40°C.
Ambient MultiplyingTemp. Correction
Degrees C Factors
10 1.2620 1.1830 1.1040 1.0050 0.90
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 39
®Other Available AmerCableVFD Cable Constructions
37-102VFD
Standard Type VFD
Power Cable• 2kV• Rated 110°C• Gexol® Insulated
37-102VFD
Low SmokeHalogen-Free
Type VFD Power Cable• 2kV• Rated 110°C• Gexol® Insulated
37-108VFD
FlexibleType TC-ER
VFD Power Cable• 600V• Rated 90°C
VFD CABLE
MOTORMOTORUV
WPE
R
S
T
PE
VFDVFD
V LL
37-102VFD
CIR Type VFD Power Cable• 2kV• Rated 110°C• Gexol® Insulated• Crush & Impact
resistant withoutexternal armoring
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961340
Tiger Stripes – Reflective
AmerCable’s reflective Tiger Stripescan extend cable life by reducing run-overs in low visibility situationsand improve mine safety by providing easier visual circuitidentification.
Black(standard)
Blue Green Orange Yellow Red
■ Increased safety for personnel through easiercircuit identification
■ Available on CPE round jacketed cables only.
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 41
®
Black/Red Blue/White Yellow/Rred Orange/Green Red/White Green/White
Black/White Blue/Green Yellow/Green Orange/White Red/Blue Black/Green
AmerCable’s standard Tiger Stripesprovide additional color combinationsby vulcanizing a contrasting colored stripeinto the jacket of our round CPE cables.
Shown below are a few examples of the many possible jacket / stripe combina-tions.
Consult with your AmerCable rep or thefactory for a complete list of availablestripe options.
Available onlyfrom AmerCable
Safetythrough easier
circuitidentification
Assign to specificequipment tomake visual
inventory simpler
Available onlyon round CPE
jacketed cables
Tiger Stripes – Standard
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961342
AmerCable TPU JacketsFor extremely abrasive environments, AmerCable’sThermoplastic Polyurethane (TPU) jacket providesthe extra-tough physical characteristics needed in the roughest mining environments.Compared to AmerCable’s standardCPE jacketing material, TPU provides:
5X more abrasion resistance
2X more tear resistance
2X more tensile strength
AmerCable CPE JacketsAmerCable’s thermoset Chlorinated Polyethylene jacket provides the physical performance andstrength needed to resist wear, tear, abrasion andcompression cuts caused by everyday mining use.
This tough, durable jacket is a proven performer in mines throughout the world. AmerCable’s engineered cable construction includes a taped-core,integral fill and tandem extrusion of the jacket layers.Two-pass jackets, extruded in tandem, yield an inseparable bond between the layers. Integral fillingof the cable core reduces torsion-induced damage.
Black(standard)
Blue Green Orange Yellow RedBlack(standard)
Blue Green Orange Yellow Red
Coloredjackets
experienceno loss ofphysical
propertiescompared to our
black jacket.
Up to8% Less
JacketWeight
Jacket Materials & Color Options
These brightlycolored cablescan improve
minesafety byproviding
easy circuitidentification.
ORANGE XLTM is AmerCable’s high strength,highly visible proprietary jacketed flat ShuttleCar cable. This cable jacket is extremely resistant to tear and abrasion. This highlydurable shuttle car cable improves productivitythrough 30-50% greater service life.
ORANGE XL
Shuttle CarProductivity
Solutions
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 43
®
Safety, Training, and Education
Field Technical SupportSafety and maximized cable productivity areAmerCable’s top priorities for our customers. Surface or underground – 24/7 – all shifts –AmerCable’s mine-experienced field reps are ready to provide on-site cable evaluation, safe handlingtraining and innovative productivity solutions.
A few extra minutes spent in cable repair can save hours of costly downtime.
Cable Splicing TrainingOur field reps can conduct on-site training (all shifts) on the correct way to splice cablesto extend their service life.
Splice Kits
(CPE or TPU)
MineCable-Safe is an investment in Safety and Productivity that brings the knowledge and experience of ourfield engineers to your mine. High voltage cables require special handling to get maximum service life andkeep personnel safe. Can you identify the difference between a productivity problem and a safety issue?Our experts can. We deliver a highly-valuable report that clearly identifies safety and productivity issues. The report includes recommendations on how to deploy, move and utilize cables more safely and to makeyour mine more productive. Follow-up can also include training sessions and engineered solutions.
Manufactured by AmerCable Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961344
Why Use
CableAssemblies?■ Your cable assembly,
built to your exact specifications, arrives ready for immediate use
■ Reduced prep, handlingand installation time
■ No need to maintain expensive connectorinventory or terminationkit inventory
■ Professionally assembled
■ Factory electrical testingafter termination/refurb
■ AmerCable’s on-time delivery rate and short lead times are #1 in thecable industry
Tiger Term
Lower Enhanced ReducedOverall Cost Reliability Installation Time
Factory Installed Cable Assemblies from AmerCable are professionallyassembled in our El Dorado, Arkansas manufacturing facility. Our team of experienced handlers join cables and connectors that match yourexact specifications. Our assemblies are designed to perform in yourharshest operating conditions.
Factory prepared cable assemblies or terminations are a reliable way to lower your overall cable connectivity costs through enhanced reliability, reduced handling and lower installation time.
FACTORYINSTALLED
Constructions■ 2 - 25kV■ Stress Cones & fill■ ID Labeling■ Pothead Assemblies
Applications■ Surface Mining■ Underground Mining■ Reeling
Tiger Term cables arrive ready for installation – saving you prep time and costs.
Our process involves properly removing copper shielding components and semi-conductive materials without damage to the underlying insulation. This is necessary for long-life and trouble-free operation.Tiger Term is available on any cable 5kV or larger.
Factory InstalledCable Assemblies
350 Bailey Road • El Dorado, Arkansas USA • www.amercable.com • e-mail: [email protected] 45
®
Molded Potheads
(up to 25kV)
Longwall RefurbishmentGet maximum service life fromyour Tiger ® Brand longwall cables. Our refurb team will expertly, clean, inspect,repair and splice in new sections as needed.
We then deliver them back to the mine – ready to power your longwall system.
Saves up to 60% when compared to the cost of a new longwall cable.
Before Refurb After Refurb
CouplersAmerCable has the coupler you need forimmediate installation upon arrival.
Factory installed couplers fromAmerCable are a reliable way to lower your overall cable connectivity costs.
Reeling
AmerCable’s Mining & Industrial Cable Products & Services
Factory InstalledCable Assemblies
IndustrialUndergroundMining
SurfaceMining
®
350 Bailey Road • El Dorado, Arkansas USA(870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613 e-mail: [email protected] • www.amercable.com
4_10© 2010, AmerCable Incorporated
AmerCable is the leading global manufacturer of surfaceand underground mining cables.
AmerCable is an ISO 9001 certified cable manufacturer that combines leading-edge technology, proven manufacturing techniques,and high quality service to deliver the finestmining cable products available.
AmerCable serves a worldwide customer base from our manufacturing facility in El Dorado, Arkansas.Our professional field engineers and customer supportteam work directly, or in partnership with a network of independent distributors, to deliver productivityenhancing cable solutions.
What can you expect from AmerCable?■ High Quality Cable with an Emphasis on Safety
■ On-time Delivery
■ Professional Sales, Support and Service
■ Strategic Inventory Locations
■ Short Lead TimesEl Dorado, Arkansas
Made in America