ANGLEATABOVE FINISH FLOORALUMINUMARCHITECTURALBLOCKINGBUILT- UP ROOFCENTERLINECONTROL JOINTCEILINGCENTERCONCRETECONCRETE MASONRY UNITCONTINUOUSDIAMETERDOWN SPOUTDRAWINGEXTERIOREXISTINGEACHEXPANSION JOINTELECTRICALELEVATIONELEVATOREQUIPMENTELECTRIC WATER COOLERFINISHFLOOR DRAINFACE OF FINISHFACE OF STUDFIRE RETARDENTFIELD VERIFYGAUGEGYPSUM BOARDHOLLOW METALHORIZONTALHEIGHTHEATING VENTILATION AIR-CONDITIONINGINSIDE DIAMETERINSULATIONJOINTLAVATORYMAXIMUMMECHANICALMANUFACTURERMINIMUMMASONRY OPENINGNOT IN CONTRACTNOMINALNOT TO SCALEON CENTEROUTSIDE DIAMETEROPENINGOPPOSITEPAINTPAIRPLATE, PROPERTY LINEPRESSURE TREATEDRADIUSREQUIREDROOF DRAINROUGH OPENING SQUARE FEETSIMILARSPECIFICATIONSSTAINLESS STEELSTANDARDSTRUCTURALSUSPENDEDTOP OF STEELTOP OF WALLTYPICALUNLESS NOTED OTHERIWSEVERTICALVINYL COMPOSITION TILEWITHWATER CLOSETWATER RESISTANTWELDED WIRE FABRICWOOD
@AFFALUMARCHBLKGBU
CJCLGCTRCONCCMUCONTDIADSDWGEXTEXISTEAEJELECELELEVEQUIPEWCFINFDFOFFOSFRFVGAGYP BDHMHORIZHTHVACIDINSULJTLAVMAXMECHMFRMINMONICNOMNTSOCODOPNGOPPPPRPLPTR, RADREQDRDRO SFSIMSPECSSSTDSTRSUSPTOSTOWTYPUNOVERTVCTW/WCWRWWFWD
CL
PLAN DETAIL REFERENCE
ROOM TAG SYMBOL
WALL SECTION / DETAIL SECTION REFERENCE
DOOR SYMBOL
ALTERNATE WALL SECTION REFERENCE
BUILDING SECTION REFERENCE
FIRE RATED WALL SYMBOLS
REVISION SYMBOL
DETAIL NUMBER
WHERE DETAIL IS SHOWN
DETAIL NUMBERWHERE DETAIL IS SHOWN
WALL SECTION / DETAIL NUMBERWHERE WALL SECTION / DETAIL IS SHOWN
ROOM NAME
ROOM NUMBER
DOOR NUMBER
FRAME TYPE
DOOR TYPE
DIMENSION TO FACE OR EDGE
DIMENSION TO CENTERLINE
ELEVATION ABOVE SEA LEVELITEM IDENTIFIED
WINDOW / STOREFRONT / CURTAIN WALL / LOUVER TYPE
PARTITION TYPE
FIRE EXTINGUISHER RECESSED IN WALL CABINET
FIRE EXTINGUISHER MOUNTED ON WALL BRACKETS
FD - FLOOR DRAIN
BUILDING SECTION NUMBERWHERE BUILDING SECTION IS SHOWN
WALL SECTION / DETAIL NUMBERWHERE WALL SECTION / DETAIL IS SHOWN
TOP = TOP HALF OF WALL FOR PARTICULAR LEVEL
BOT = BOTTOM HALF OF WALL FOR PARTICULAR LEVEL
WALL SECTION / DETAIL NUMBERWHERE WALL SECTION / DETAIL IS SHOWN
SIM = SIMILAR CONDITIONOH = OPPOSITE HAND CONDITIONOPP = OPPOSITE HAND CONDITIONROT = ROTATED CONDITION
ONE-HOUR FIRE-RATED WALL ASSEMBLY
TWO-HOUR FIRE-RATED WALL ASSEMBLY
FOUR-HOUR FIRE-RATED WALL ASSEMBLY
SEE PARTITION TYPES FOR UL DESIGN NO'S.
BRICK VENEER / CMU CONTROL JOINT
TOILET / LOCKER ROOM ACCESSORY SYMBOL
GYPSUM BOARD CONTROL JOINT
INDICATES A CHANGE IN ORIENTATION OF CUT PLANE(INTERIOR ELEVATION ONLY)
CLOUD AROUND REVISION
EXTERIOR WALL / ROOF CONSTRUCTION TYPE
TITLESCALE: 1'-0" = 1'-0" REF: 1/A1.1
1A1.1
LOCATION OF DETAIL CUT (AS SHOWN)
1A1.1
1A1.1
1
BOT
TOP
SIM
001ADX FX
S1
1A
FE-C FE-C
100RECEPTION
1A1.1
1A1.1
1A1.1
1A1.1
EXPANSION JOINT TYPEA
26
26
95
2620
85 38577
20
95
26 CAROLINA
GEORGIA
NORTH
ATLANTIC OCEAN
COLUMBIA
STATE OFSOUTH CAROLINA
MAPNORTH
CLEARANCES TO COMPLY WITH LATEST VERSION OF ANSI A117.1 ADOPTED BY GOVERNING BODY
NOTE: DIMENSIONS AND CLEARANCES SHOWN MUST BE PROVIDED AT ALL DOORS. CONTRACTOR SHALL REVIEW FIELD LAYOUT AND CONFIRM THAT ALL OF THE APPROPRIATE CLEARANCES ARE PROVIDED. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION. ANY REMEDIAL WORK THAT SHOULD HAVE BEEN AVOIDED BY BRINGING DISCREPANCIES TO THE ARCHITECT'S ATTENTION SHALL BE AT THE CONTRACTOR'S EXPENSE.
TWO HINGED DOORS IN A SERIES
HINGE SIDE APPROACHES
FRONT APPROACHES
LATCH SIDE APPROACHES
PULL SIDE
36" MIN.
42" MIN.
60" M
IN.
PULL SIDE
PUSH SIDE
PUSH SIDE
PUSH SIDE
PULL SIDE
60" M
IN.
18" MIN.
48" M
IN.
24" MIN.54" M
IN.
IF D
OOR
HAS
CLOS
ER
24" MIN.
42" M
IN.
48" M
IN.
IF D
OOR
HAS
CLOS
ER
12" MIN.IF DOOR HAS BOTHCLOSER AND LATCH
52" M
IN.
12" MIN.
42" M
IN.
48" M
IN. IF
DOO
R HA
SIF
BOT
H CL
OSER
AND
LATC
H
48" M
IN.
60" MIN.
48" M
IN.
60" MIN.
PUSH / PUSH
PUSH / PULL
60" MIN.
PULL / PUSH
64" M
IN.
(W/ 54" CLEAR)
(W/ 60" CLEAR)
IF BOTH CLOSER AND LATCH
22" MIN.54" M
IN.
COMPACTED EARTH
POROUS FILL (STONE OR GRAVEL)
CONCRETE
CONCRETE MASONRY UNIT (CMU)
BRICK
SAND, PLASTER, CEMENT, GROUT
STEEL
WOOD (ROUGH)
WOOD (FINISHED)
PLYWOOD
BATT INSULATION
GYPSUM BOARD
RIGID INSULATION
ARCHITECTURAL
MECHANICAL
PLUMBING
FIRE PROTECTION
ELECTRICAL
T1.1 TITLE SHEET, INDEX TO DRAWINGS, CODE INFORMATION & LIFE SAFETY PLAN
A1.1 GROUND FLOOR AND DEMOLITION PLANSA2.1 GROUND FLOOR REFLECTED CEILING PLAN AND CEILING DEMOLITION PLANA3.1 ELEVATIONS, SECTIONS, PARTITION TYPES, DOOR SCHEDULE AND DETAILSA4.1 FINISHES
MD1.1 HVAC DEMOLITION FLOOR PLANM1.1 HVAC RENOVATION FLOOR PLANM2.1 HVAC DETAILS, NOTES, SCHEDULES AND LEGEND
PD1.1 DEMOLITION PLANP1.1 FLOOR PLANS, NOTES, SCHEDULE AND LEGEND
FP1.1 FLOOR PLAN AND NOTES
E0.1 ELECTRICAL NOTES & LEGENDSE0.2 ELECTRICAL ONE-LINE DIAGRAM & PANELBOARD SCHEDULEE1.1 LIGHTING PLANSE2.1 POWER/SYSTEMS PLANSE3.1 MECHANICAL ELECTRICAL PLANS
PROJECT DESIGNED IN ACCORDANCE WITH:
1.2.3.4.5.6.7.
8.9.10.11.12.
13.14.
INTERNATIONAL BUILDING CODE (IBC), 2015 EDITIONINTERNATIONAL EXISTING BUILDING CODE (IEBC), 2015 EDITIONINTERNATIONAL FIRE CODE (IFC), 2015 EDITIONINTERNATIONAL ENERGY CONSERVATION CODE (IECC), 2009 EditionINTERNATIONAL FUEL GAS CODE (IFGC), 2015 EDITIONINTERNATIONAL MECHANICAL CODE (IMC), 2015 EDITIONINTERNATIONAL PLUMBING CODE (IPC), 2015 EDITION with the following insertions:
1. Section 305.4.1, insert “18” and insert “18”2. Section 903.1, insert “8”
INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE (IPSDC), 2015 EDITIONINTERNATIONAL PROPERTY MAINTENANCE CODE (IPMC), 2015 EDITIONNATIONAL ELECTRICAL CODE (NEC) [NFPA-70], 2014 EDITIONNATIONAL ELECTRICAL SAFETY CODE, IEEE-C2-2012 EDITIONAMERICAN NATIONAL STANDARDS INSTITUTE, INC. (ANSI) - A117.1 - 2017, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIESSTATE FIRE MARSHAL RULES, REGULATIONS, AND POLICIES - LATEST EDITIONSTATE OF SC TELEPHONE EQUIPMENT ROOM AND COMMUNICATIONS/DATA SYSTEMS POLICY AS FORMULATED BY THE DSIT
EXISTING BUILDING GENERAL CODE INFORMATION: DESIGNED c. 1966 UNDER CURRENT CODE AT THE TIME
EXISTING BUILDING OCCUPANCY: ASSUMED MIXED USE - ASSEMBLY (A-1) AND BUSINESS (B)
EXISTING CONSTRUCTION CLASSIFICATION: ASSUMED TYPE IIB, NON-SPRINKLERED, WITH FIRE ALARM (RECENT RENOVATIONS IN 2009, 2017 AND 2018 ON GROUND FLOOR ARE SPRINKLERED PER NFPA-13)
PROJECT SCOPE RELEVANT CODE INFORMATION: GROUND FLOOR (ATHLETIC LEVEL)
NEW USE - RENOVATION AREA AREA PER PERSON OCCUPANT LOAD
BUSINESS (B) 850 SF 100 GROSS 9
TOTAL: 850 SF 9
- DISTANCE BETWEEN EXITS = MIN. ONE-THIRD LENGTH OF MAX. OVERALL DIAGONAL (SPRINKLERED) (PER TABLE 1007.1.1)- MAX. COMMON PATH OF EGRESS TRAVEL DISTANCE = 100' (SPRINKLERED) (PER TABLE 1006.2.1)- MAX. EXIT ACCESS TRAVEL DISTANCE = 300' (SPRINKLERED) (PER TABLE 1017.2)
NOTESA. TRAVEL DISTANCES ARE BEING CONSIDERED FOR SPRINKLERED BUILDING SINCE ALL RENOVATED SPACE IS SPRINKLERED
PER NFPA-13. OTHER EXISTING/NON-RENOVATED SPACES IN ORIGINAL BUILDING (COLISEUM) ARE NON-SPRINKLERED.
B. CURRENT FIRE RATINGS ARE BEING MAINTAINED/NOT CHANGING.
C. INCIDENTAL USE SEPARATION IS REQUIRED PER 2015 IBC 509.1 FOR LAUNDRY ROOMS OVER 100 SF. SINCE AREA IS BEINGSPRINKLERED, 1-HOUR FIRE RATED SEPARATION NOT REQUIRED (TABLE 509).
TRASH203
LAUNDRY ACCESS203A
LAUNDRY203B
FOOD SERVICE201D
STAIRST02
FOOD STORAGE201C
KITCHEN201
STAIRST01
ELECTRICAL202
HALLWAYH107
RAMPH213
240
69' TO DOOR
ALONG MAIN
EGRESS PATH
BUSINESS (100 GROSS)[825 SF = 9 P]
242
25+2=27272
9P
9P
FIRE ALARM204 JANITOR 205
ST03
FE-B
FE-B
164P+9P=173
(8 EXIT DOORS)
TO EXIT
ONE EXIT REQUIRED BUT SIGNING STAIR FOR
SECONDARY EGRESS PATH
FIRE EXTINGUISHER, BRACKET MOUNTED. SEE SPECS.FE-B
EXIT LIGHTS - ALSO SEE ELECTRICAL DRAWINGS
REQUIRED EGRESS WIDTH AT DOOR, IN INCHESEGRESS WIDTH PROVIDED AT DOOR, IN INCHES
EGRESS WIDTH SYMBOLS534
4' - 0"(3'-8") REQUIRED EGRESS WIDTH AT PASSAGE
EGRESS WIDTH PROVIDED AT PASSAGE
23 # OF PEOPLE/DIRECTION OF TRAVEL
[9,960 SF = 50 P] NET (OR GROSS) SQ. FT./# OF PEOPLE (OCCUPANCY OF SPACE)
TRAVEL DISTANCE LEGEND45'
TRAVEL DIST.
300' TO EXIT FROM REMOTE CORNER
1. EXIT SIGNS ALSO SHOWN ON ELECTRICAL DRAWINGS
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
1/22
/201
9 1:
01:4
3 PM
T1.1U501
.18
01.2
2.19
TITL
E SH
EET,
INDE
X TO
DRA
WIN
GS,
CODE
INFO
RMAT
ION
& LI
FE S
AFET
YPL
AN
Auth
or
Chec
ker
COLI
SEUM
LAU
NDRY
EQU
IPM
ENT
RELO
CATI
ONCa
rolin
a Co
liseu
m70
1 As
sem
bly S
t.Co
lumbia
, SC
2920
8
COLISEUM LAUNDRY EQUIPMENT RELOCATIONUNIVERSITY OF SOUTH CAROLINA
22 JANUARY 2019CONSTRUCTION DOCUMENTS
ABBREVIATIONS ARCHITECTURAL SYMBOLS
LOCATION MAP MANEUVERING CLEARANCES
MATERIAL DESIGNATIONS
INDEX TO DRAWINGS
CAROLINA COLISEUM701 ASSEMBLY STREET COLUMBIA, SOUTH CAROLINA 29208USC Project Number: FP00000296 Architect's Project Number: U501.18
CODE INFORMATION - GENERAL
CODE INFORMATION - LAUNDRY
REVI
SIO
N S
NO.
NAM
EDA
TE
REFERENCED ON:
3/16" = 1'-0"T1.1 A3.11 LIFE SAFETY PLAN
LEGEND - LIFE SAFETY
GENERAL NOTES - LIFE SAFETY
UP
UPUP
UP
UP
UPUP
UP
4
3' - 8
"2'
- 8"
1
2
3
1' - 4
"4'
- 0"
5
EXISTING ROLL-UP DOOR TO REMAIN
6
6
8
8
8
8
5
8
8
TRASH203
LAUNDRY203B
FOOD SERVICE201D
STAIRST02
FOOD STORAGE201C
KITCHEN201
STAIRST01
ELECTRICAL202
HALLWAYH107
RAMPH213
CLOSET203C
7
9
10
REFERENCE ABATEMENT SPECIFICATIONS FOR KNOWN AREAS CONTAINING HAZARDOUS MATERIALS. CONTACT OWNER UPON DISCOVERY OF ANY SUSPECTED ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BE REMOVED IN THE PROJECT SCOPE.
1 DEMO CMU WALL FOR NEW HOLLOW METAL FRAME. SAW CUT OPENING AS REQUIRED. SEE FRAME SCHEDULE FOR SIZE.
DEMO CMU WALL FOR NEW HOLLOW METAL DOOR AND FRAME. SAW CUT OPENING AS REQUIRED. SEE DOOR AND FRAME SCHEDULE FOR SIZE.
DEMO EXISTING HM DOOR AND FRAME. INFILL OPENING WITH 8" CMU. PAINT/FINISH TO MATCH EXISTING.
DEMO EXISTING CHALKBOARD
DEMO EXISTING CASEWORK
REMOVE EXISTING CARPET
REMOVE EXISTING DRINKING FOUNTAIN, SEE PLUMB. DWGS. FILL IN WALL WITH SIMILAR CONSTUCTION TO MATCH EXISTING WALL CONSTRUCTION.
REMOVE EXISTING WALLPAPER AND WOOD PANELING FROM ALL WALLS
DEMOLISH EXISTING CONC. SLAB AND TILE AS REQ'D. FOR PLUMBING TIE-IN, SEE PLUMB. DWGS.
EXISTING 3-COMPARTMENT SINK TO REMAIN
2
3
4
5
6
7
8
9
10
EXSITING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
EXISTING DOOR AND FRAME TO BE DEMOLISHED
EXISTING DOOR AND FRAME TO BE REMAIN
NOTE: SEE KEYNOTES AND PLUMBING, MECHANICAL AND ELECTRICAL DEMO DRAWINGS FOR ADDITIONAL DEMO WORK
EXISTING FLOOR SLAB AND FINISHES TO BE DEMOLISHED FOR PLUMBING TIE-IN. REPOUR SLAB AND REPLACE FINISHES WHEN WORK COMPLETE. SEE FINISH SCHEDULE.
1. FIELD VERIRY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION AND NEW WORK. EXISTING BUILDING INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGS PROVIDED BY THE OWNER AND SELECTIVE FIELD MEASUREMENTS. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.
2. PROVIDE AND INSTALL ALL SHORING AND SUPPORT SYSTEMS NECESSARY TO ENSURE EXISTING STRUCTURE TO REMAIN STABLE THROUGHOUT DEMOLITION AND NEW CONSTRUCTION.
3. WHERE APPLICABLE, REFERENCE ABATEMENT SPECIFICATIONS FOR KNOWN AREAS CONTAINING HAZARDOUS MATERIALS. CONTACT OWNER UPON DISCOVERY OF ANY SUSPECTED ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BE REMOVED IN THE PROJECT SCOPE.
4. CONTRACTOR SHALL PHOTOGRAPH ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION OR NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT AND OWNER WITH ELECTRONIC COPY OF PHOTOGRAPHS.
5. ITEMS TO SALVAGED AND REMOVED BY THE OWNER PRIOR TO DEMOLITION ARE IDENTIFIED WITHIN THE SPECIFICATIONS.
6. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH EXISTING CONDITIONS FOR SIZES, QUANTITIES AND LOCATIONS.
7. PROTECT ALL EXISTING PIPING & INSULATION, CONDUIT/BOXES, WIRING, LIGHTING, DUCTWORK, SPRINKLER PIPING, AND ALL OTHER UTILITIES TO REMAIN IN USE. REMOVE ALL ABANDONED OR DISCONNECTED ITEMS FROM ABOVE CEILINGS.
8. ALL FURNITURE, FIXTURES AND LOOSE ITEMS TO BE REMOVED BY OWNER BEFORE COMMENCEMENT OF WORK.
9. PATCH, CLEAN, SCRAPE AND OTHERWISE PREP ALL AFFECTED WALLS, CEILINGS AND FLOORS WHERE ITEMS ARE REMOVED OR WERE REMOVED BY OWNER TO PREPARE AREAS FOR FINAL WORK AND FINISHES AS SPECIFIED. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
SEE T1.1 FOR MINIMUM REQUIRED ADA MANEUVERING CLEARANCES. VERIFY EXACT FEB AND FEC LOCATIONS WITH ARCHITECT..
SEE T1.1 FOR REQUIRED UL ASSEMBLIES OF ALL BUILDING SYSTEMS. ALL PENETRATIONS THROUGH RATED WALL AND FLOOR ASSEMBLIES MUST COMPLY WITH UL DESIGN FOR PENETRATIONS.
DIMENSIONS INDICATED ON THESE DRAWINGS ARE TO FACE OF CMU WALL, FACE OF EXTERIOR VENEER, FACE OF STUD WALL, OR CENTERLINE OF COLUMN UNLESS OTHERWISE INDICATED. COORDINATE ALL DIMENSIONS WITH STRUCTURAL DIMENSION PLANS, ENLARGED PLANS, SECTION AND DETAIL DRAWINGS, AND STRUCTURAL DRAWINGS AND VERIFY EXACT LOCATIONS. COORDINATE ALL FLOOR SLAB PENETRATIONS WITH SYSTEM DRAWINGS (S'S, M'S, P'S, FP'S, AND E'S) AND ACTUAL PRODUCT TO BE INSTALLED AND VERIFY LOCATIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION.
SEE FINISH SCHEDULE AND PLAN FOR FLOOR PATTERNS AND FLOOR FINISH REFERENCES
EXISTING AND MASONRY OPENINGS TO RECEIVE CURTAIN WALL, DOORS, WINDOWS, LOUVERS, OR OTHER ELEMENTS SHALL BE FIELD VERIFIED PRIOR TO MANUFACTURE OF SYSTEM.
INTERIOR METAL STUD OPENINGS TO RECEIVE STOREFRONT, DOORS, GRILLES, LOUVERS, OR OTHER ELEMENTS SHALL BE FIELD VERIFIED PRIOR TO MANUFACTURE OF SYSTEM. LOCATION OF ALL RECESSED CABINETS AND EQUIPMENT WALL PENETRATIONS MUST BE VERIFIED PRIOR TO INSTALLATION OF CMU WALLS TO ENSURE INDICATED LOCATION AND EVEN COURSING. ANY CONFLICTS WITH INDICATED DIMENSIONS OR LOCATIONS SHALL BE COORDINATED WITH ARCHITECT PRIOR TO INSTALLATION..
CONTACT OWNER UPON DISCOVERY OF ANY SUSPECTED ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BE REMOVED WITHIN THE PROJECT SCOPE.
PATCH, CLEAN, SCRAPE AND OTHERWISE PREP ALL AFFECTED WALLS, CEILINGS AND FLOORS WHERE ITEMS ARE REMOVED OR WERE REMOVED BY OWNER TO PREPARE AREAS FOR FINAL WORK AND FINISHES AS SPECIFIED. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
1.
2.
3.
4.
5.
6
7.
8.
FIRE EXTINGUISHER, BRACKET MOUNTED. SEE SPECS.
REFERNCE LIFE SAFETY PLAN SHEET T1.1 FOR EXISTING CMU OR CONCRETE WALLS ASSUMED AS EQUIVALENT TWO-HOUR FIRE-RATED WALL ASSEMBLIES FROM EXISTING CONSTRUCTION
FE-B
6' - 8
1/2
"
SLOPE DN 12"
DUMPSTER
DUMPSTER
CARD
BOAR
D
COMPACTOR
STORAGE BARRELS
TRASH203
LAUNDRY ACCESS203A
WASHERDRYER
12" CONC. PAD AND RAMP
RAMP SLOPE UP
LAUNDRY203B
FOOD SERVICE201D
12" RAISED CONC. CURB, SEE DETAILS
NEW HOLLOW METAL DOOR AND FRAME
NEW 3-5/8" METAL STUD AND GWB WALL AND FRAMED CEILING AT 9'-0" AFF
HOLLOW METAL FRAME (NO DOOR)
3' - 0"
4' - 0" 9' - 0"
ROOF DRAIN TO REMAIN
NEW ELEC. PANEL, SEE ELEC. DWGS.
FD
1' - 4
"4'
- 0"
A3.1 1
3
A3.1
2
A3.1
NEW SLOPED CONC. TRANSITION FROM DOOR THRESHOLD TO RAMP. CHIP OUT EXISTING CONCRETE AS REQ'D. TO ACCEPT NEW CONC. RAMP
A3.14
NEW 8" CMU INFILL WALL AT PREVIOUS DOOR OPENING. MATCH CMU COURSING AND PAINT FOOD SERVICE SIDE TO MATCH EXISTING
STAIRST02
203AAD1 F1
FOOD STORAGE201C
KITCHEN201
STAIRST01
ELECTRICAL202
HALLWAYH107
RAMPH213
CLOSET203C
5
3' - 8
"2'
- 8"
8
A3.1
FE-B
FE-B
6
7
M3A
10
A3.1
3' - 6
"2'
- 6"
12' - 0"
TRASH ROOM EQUIP. TO BE RELOCATED BY OWNER
POLYPROPELENE DRAIN TROUGH AND LINT INTERCEPTOR, SEE PLUMB. DWGS.
3' - 0
"
DRYER EXHAUST, SEE MECH. DWGS.
FUTURE WASHERWASHERDRYERDRYERDRYERDRYER
A3.114
203AB-- F2
WASHERS AND DRYERS PROVIDED BY OWNER
NEW RELIEF DAMPER, SEE MECH. DWGS. CUT OPENING IN EXISTING WALL AS REQUIRED. COORDINATE FINAL LOCATION WITH A/E BEFORE CUTTING. COORDINATE REMOVAL OF HAZARDOUS EXTERIOR COATING WITH OWNER PRIOR TO CUTTING OPENING IN WALL.
1' - 0" 0' - 0"
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
1/22
/201
9 1:
01:3
4 PM
A1.1U501
.18
01.2
2.19
GROU
ND F
LOOR
AND
DEM
OLIT
ION
PLAN
S
Auth
or
Chec
ker
COLI
SEUM
LAU
NDRY
EQU
IPM
ENT
RELO
CATI
ONCa
rolin
a Co
liseu
m70
1 As
sem
bly S
t.Co
lumbia
, SC
2920
8
REFERENCED ON:
1/4" = 1'-0"A1.1 A3.11 DEMOLITION PLAN
KEYNOTES - DEMO PLAN
LEGEND - DEMOLITION PLAN
GENERAL NOTES - DEMO PLAN
GENERAL NOTES - FLOOR PLAN
LEGEND - FLOOR PLAN
REVI
SIO
N S
NO.
NAM
EDA
TE
REFERENCED ON:
1/4" = 1'-0"A1.1 A3.12 FLOOR PLAN
3
A3.1
2
A3.18
A3.1
LAUNDRY203B
TRASH203
LAUNDRY ACCESS203A
FOOD SERVICE201D
STAIRST02
FOOD STORAGE201C
KITCHEN201
STAIRST01
ELECTRICAL202
HALLWAYH107
RAMPH213
CLOSET203C
9' - 0"
14' - 4"EXPOSED CONCRETE STRUCTURE
NEW BULKHEAD WITH 5/8" GWB ON 3-5/8" METAL STUD FRAMING TO CONC. STRUCTURE ABOVE TO SEAL OFF LAUNDRY ROOM FROM OPEN CEILING SPACE
EQEQ
EQ EQ
SLOPES UP
NOT ALL MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL PIPING SHOWN FOR CLARITY. SEE M, P, FP AND E DWGS.
EXISTING PLASTER CEILING TO REMAIN. SCRAPE OFF LOOSE PAINT, SAND AND PREP FOR NEW PAINT COATING
NEW RELIEF DAMPER, SEE MECH. DWGS. CUT OPENING IN EXISTING WALL AS REQUIRED. COORDINATE FINAL LOCATION WITH A/E BEFORE CUTTING. COORDINATE REMOVAL OF HAZARDOUS EXTERIOR COATING WITH OWNER PRIOR TO CUTTING OPENING IN WALL.
NOT ALL MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL PIPING SHOWN FOR CLARITY. SEE M, P, FP AND E DWGS.
SEE ELEC. DWGS. FOR FULL SCOPE OF WORK RELATED TO ELECTRICAL LIGHTING AND DEVICES IN HALLWAY
SUSP. LIGHT FIXTURES, TYP.
14' - 4"EXPOSED CONCRETE STRUCTURE
HVAC UNIT AND DUCTWORK, SEE MECH. DWGS.
2' - 2
"6'
- 0"
1' - 2
"
8' - 0" 4' - 0" 4' - 0" 8' - 0"
1
2
3 3
4
SLOPES UP
EXISTING PLASTER CEILING TO REMAIN. SCRAPE OFF LOOSE PAINT, SAND AND PREP FOR NEW PAINT COATING
TRASH203
STAIRST02
LAUNDRY203B REFERENCE ABATEMENT SPECIFICATIONS FOR KNOWN AREAS CONTAINING
HAZARDOUS MATERIALS. CONTACT OWNER UPON DISCOVERY OF ANY SUSPECTED ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BE REMOVED IN THE PROJECT SCOPE.
REFERENCE MECH. AND ELEC. DEMOLITION DRAWINGS FOR FULL EXTENT OF DEMOLITION REQUIREMENTS.
REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND SPECIFIC FIXTURE DESIGNATIONS, AND FOR ELECTRICAL CEILING AND WALL MOUNTED DEVICES.
ALL SUSPENDED ACOUSTICAL GRIDS ARE TO BE LOCATED AS SHOWN, UNLESS NOTED OTHERWISE. REFERENCE NOTES FOR GRID START POINTS AND FULL-TILE LOCATIONS. REVIEW ALL GRID LAYOUTS WITH ARCHITECT PRIOR TO INSTALLATION TO ASSURE NO "SLIVERS" OF TILE, OVERLAPPING WALL MOLDS, OR OUT-OF-SQUARE CONDITIONS OCCUR. GRIDS NOT COMPLYING WITH THIS PROCESS OR THESE STIPULATIONS WILL BE REMOVED AND RE-INSTALLED AT CONTRACTOR'S EXPENSE.
CEILING MOUNTED EQUIPMENT, DEVICES, FIXTURES & GRILLS MUST BE COORDINATED ON REFLECTED CEILING PLANS. CEILING MOUNTED SPRINKLERS TO BE LOCATED IN CENTER OF CEILING TILE IN APC CEILINGS AND ALIGNED WITH DOWNLIGHTS IN GWB CEILINGS/SOFFITS.
SEE FP DRAWINGS FOR FIRE PROTECTION SYSTEM LAYOUT. COORDINATE ROUTING OF PIPING W/ ARCHITECTURAL DWGS AND DETAILS AS WELL AS ALL OTHER SYSTEM DRAWINGS (S's, M's, P's, & E'S). SUBMIT LAYOUT/COORDINATION DRAWING FOR REVIEW & APPROVAL PRIOR TO INSTALLATION.
PAINT EXPOSED STRUCTURE/CEILING AREA AND UTILITIES ONLY AS NOTED ON FINISH SCHEDULES AND INTERIOR ELEVATIONS.
ACCESS PANELS BY GENERAL CONTRACTOR. QUANTITY OF ACCESS PANELS SHOWN ON ARCHITECTURAL DRAWINGS NOT INTENDED TO BE ALL INCLUSIVE; SEE MECHANICAL DRAWINGS, PLUMBING DRAWINGS, ELECTRICAL DRAWINGS, AND FIRE PROTECTION SHOP DRAWINGS FOR ADDITIONAL ACCESS PANELS NOT SHOWN. COORDINATE EXACT LOCATION OF ACCESS PANELS NOT SHOWN WITH ARCHITECT. BRING ALL MECHANICAL, PLUMBING AND ELECTRICAL ITEMS WHICH NEED ACCESS TO THE ACCESS PANEL LOCATIONS SHOWN - BRING THE NEED FOR ADDITIONAL ACCESS PANELS TO THE ARCHITECT'S ATTENTION BEFORE PROCEEDING.
1.
2.
3.
4.
5.
6.
SUPPLY & RETURN MECHANICAL DIFFUSERS, SEE MECH. DWGS.
GYPSUM BOARD CEILING / SOFFIT AS SPECIFIED
LIGHT FIXTURES, SEE ELEC. DWGS.
EXIT LIGHTS - SEE ELEC. DWGS. AND LIFE SAFETY PLAN FOR LOCATIONS
9' - 8" SHOWS CEILING HEIGHTS RELATIVE TO MAIN 0'-0" FINISHED FLOOR ELEVATION
1 DEMO ALL CEILING GRID IN THIS SPACE
DEMO EXISTING LIGHT FIXTURES, SEE ELEC. DWGS.
DEMO EXISTING HVAC UNITS, SEE MECH. DWGS.
DEMO EXISTING PROJECTION SCREEN AND HOUSING
2
3
4
1. FIELD VERIRY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION AND NEW WORK. EXISTING BUILDING INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGS PROVIDED BY THE OWNER AND SELECTIVE FIELD MEASUREMENTS. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.
2. WHERE APPLICABLE, REFERENCE ABATEMENT SPECIFICATIONS FOR KNOWN AREAS CONTAINING HAZARDOUS MATERIALS. CONTACT OWNER UPON DISCOVERY OF ANY SUSPECTED ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BE REMOVED IN THE PROJECT SCOPE.
3. CONTRACTOR SHALL PHOTOGRAPH ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION OR NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT AND OWNER WITH ELECTRONIC COPY OF PHOTOGRAPHS.
4. ITEMS TO SALVAGED AND REMOVED BY THE OWNER PRIOR TO DEMOLITION ARE IDENTIFIED WITHIN THE SPECIFICATIONS.
5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH EXISTING CONDITIONS FOR SIZES, QUANTITIES AND LOCATIONS.
6. PROTECT ALL EXITING PIPING & INSULATION, CONDUIT/BOXES, WIRING, LIGHTING, DUCTWORK, SPRINKLER PIPING, AND ALL OTHER UTILITIES TO REMAIN IN USE. REMOVE ALL ABANDONED OR DISCONNECTED ITEMS FROM ABOVE CEILINGS.
7. ALL FURNITURE, FIXTURES AND LOOSE ITEMS TO BE REMOVED BY OWNER BEFORE COMMENCEMENT OF WORK.
8. PATCH WALLS, CEILINGS AND FLOORS WHERE ITEMS ARE REMOVED OR WERE REMOVED BY OWNER TO PREPARE AREAS FOR FINAL WORK AND FINISHES AS SPECIFIED.
9. SEE MECHANICAL, PLUMBING AND ELECTRICAL DEMOLITION PLANS AND NOTES FOR DEMOLITION OF LIGHTS, DEVICES, DUCTWORK, PIPING, ETC. ABOVE CEILINGS. PREPARE ALL AREAS FOR NEW CEILNGS AND UTILITIES INCLUDING RAISING AND/OR REMOVAL OF CONDUIT, PIPING, DUCTWORK, ETC. NECESSARY TO ACHIEVE NOTED CEILING HEIGHTS. CONSULT WITH ARCHITECT SHOULD ANY UTILITY CONFLICTS ARISE.
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
1/22
/201
9 1:
01:3
6 PM
A2.1U501
.18
01.2
2.19
GROU
ND F
LOOR
REF
LECT
EDCE
ILIN
G PL
AN A
ND C
EILI
NGDE
MOL
ITIO
N PL
AN
Auth
or
Chec
ker
COLI
SEUM
LAU
NDRY
EQU
IPM
ENT
RELO
CATI
ONCa
rolin
a Co
liseu
m70
1 As
sem
bly S
t.Co
lumbia
, SC
2920
8
REFERENCED ON:
1/4" = 1'-0"A2.1 A3.11 REFLECTED CEILING PLAN
REFERENCED ON:
1/4" = 1'-0"A2.1 A3.12 DEMOLITION REFLECTED CEILING PLAN
GENERAL NOTES - REFLECTED CEILING PLAN
LEGEND - REFLECTED CEILING PLAN
KEYNOTES - DEMO RCP
GENERAL NOTES - DEMO RCP
REVI
SIO
N S
NO.
NAM
EDA
TE
1 LAYER 5/8" GYPSUM WALL BOARD EACH SIDE
20 GAGE METAL STUDS @ 16" O.C. MAX.(SEE SPECIFIC PARTITION TYPE FOR SIZE)
WALL FINISH, SEE FINISH SCHEDULE
STEEL RUNNER ATTACHED TO CONCRETE SLAB AT 12" O.C. MAX.@ TOP AND BOTTOM OF WALL
CONCRETE SLAB FINISH FLOOR MATERIAL, SEE FINISH SCHEDULE
BASE, SEE FINISH SCHEDULE
6" - 18 GAGE METAL STUD CEILING JOISTS AT 16" O.C. MAX.
1 LAYER 5/8" GYPSUM WALL BOARD CEILING
BASE, SEE FINISH SCHEDULE
3/4" WOOD TRIM FULL LENGTH OF WALL, PTD. WALL COLOR
5/8" PLYWOOD SHEATHING
3 1/
2"
M1M2M3M4M6M8
M2A*
MATERIAL FINISH CONSTRUCTION
SIZE
SEE CHART BELOW
SEE CHART BELOW
SEE PARTITION SECTION
1-1/2" METAL STUD2-1/2" METAL STUD3-5/8" METAL STUD4" METAL STUD6" METAL STUD8" METAL STUD
W2W4W6W8
2X2" WOOD STUD2X4" WOOD STUD2X6" WOOD STUD2X8" WOOD STUD
C4C8C12
4" CMU (3-5/8" NOM.)8" CMU (7-5/8" NOM.)12" CMU (11-5/8" NOM.)
INSULATION DESIGNATION
S2 2" C-H STUD (SHAFT WALL)
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
1' - 0
"7'
- 4"
4' - 0" 1' - 4"
NEW H.M. DOOR AND FRAME(FRAME 4'-0" X 7'-4") CUT INTO CMU WALL
EXISTING HM DOOR AND FRAME
EXISTING SPRINKLER VALVE TO REMAIN
EXISTING LIGHT SWITCH TO REMAIN
NEW SLOPED CONC. TRANSITION FROM DOOR THRESHOLD TO RAMP
EXISTING ROLL-UP DOOR
HVAC DUCTWORK, SEE MECH. DWGS.
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
3
A3.1
LAUNDRY ACCESS203A
7' - 4
"1'
- 0"
EXISTING CONC. SLAB AND RAMP
9' - 0"4' - 0"
WALL PROTECTION, SEE FINISH SCHED. AND SPECS
LAUNDRY203B
NEW H.M. DOOR AND FRAME
HOLLOW METAL CASED OPENING FRAME, F2
STAINLESS STEEL CORNER GUARDS ON H.M. FRAME, SEE SPECS
STAINLESS STEEL CORNER GUARDS ON H.M. FRAME, SEE SPECS.
A3.19
4' - 0
"
1' - 0
"3'
- 0"
RESILIENT BASE, RB-1
CONC. LANDING AND RAMP -3000 PSI CONCRETE WITH WWF 6 X 6 - W1.4 X W1.4 OVER EXISTING SLAB
1 1/
2"
A3.112
A3.115
PAINTED GWB, SEE FINISH SCHED.
OPEN TO TRASH ROOM BEYOND
6" METAL STUDS @ 16" O.C. WITH 5/8" GWB CEILING ON BOTTOM AND 5/8" PLYWOOD SHEATHING ON TOP. SEE PARTITION TYPE FOR DETAILS
HVAC DUCTWORK BEYONDLIGHT FIXTURE, SEE ELEC. DWGS.
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
9' - 0
"
LAUNDRY ACCESS203A
OPEN
2
A3.1
3-5/8" METAL STUDS @ 16" O.C. WITH 5/8" GWB BOTH SIDES. SEE PARTITION TYPE FOR DETAILS
CONC. RAMP IN FOREGROUND
EXISTING CONC. COLUMN BEYOND
TRASH203
COMPACTOR
ROOF DRAIN BEYOND
H.M. CASED OPENING FRAME BEYOND
STAINLESS STEEL CORNER GUARDS, SEE SPECS.
6" METAL STUDS @ 16" O.C. WITH 5/8" GWB CEILING ON BOTTOM AND 5/8" PLYWOOD SHEATHING ON TOP. SEE PARTITION TYPE FOR DETAILS
6' - 8 1/2"
CONC. FLOOR ABOVE
4' - 0
"DUMPSTER
SUSPENDED HVAC UNIT AND DUCTWORK, SEE MECH. DWGS.
CARDBOARD
F1
INTERIORHOLLOW METAL
(RABBETED FRAME WITH DOOR)
2" DOOR WIDTH 2"
4"DO
OR H
EIGH
T
D1
INTERIOR1-3/4" HOLLOW METAL DOOR W/
PAINTED FINISH
DOOR WIDTH
DOOR
HEI
GHT
F2
INTERIORHOLLOW METAL
(NON-RABBETED FRAME WITHOUT DOOR)
2" DOOR WIDTH 2"
4"DO
OR H
EIGH
T
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
2
A3.1
OPEN
ELEC.PANEL
DRYER
7' - 8
"
2' - 8" 3' - 8"
FE-B
HOLLOW METAL FRAME (NO DOOR), P-3STAINLESS STEEL CORNER GUARDS ON H.M. FRAME, SEE SPECS
RESILIENT BASE, RB-1
3' - 1
0"
LAUNDRY203B
SUSPENDED LIGHT FIXTURES, SEE ELEC. DWGS.
4' - 0
"
SUSPENDED HVAC UNIT AND DUCTWORK, SEE MECH. DWGS.
8' - 8
"
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
10
A3.1
RESILIENT BASE, RB-1
DRYER DRYER DRYER DRYER DRYER
WASHER WASHER
12" HIGH CONC. WASHING MACHINE HOUSEKEEPING CURB
1' - 0
"
LAUNDRY203B
SUSPENDED LIGHT FIXTURES, SEE ELEC. DWGS.
FUTUREWASHER
SUSPENDED HVAC UNIT AND DUCTWORK, SEE MECH. DWGS.
8' - 8
"
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
NEW BULKHEAD WITH 5/8" GWB ON 3-5/8" METAL STUD FRAMING TO CONC. STRUCTURE ABOVE TO SEAL OFF LAUNDRY ROOM FROM OPEN CEILING SPACE
RESILIENT BASE, RB-1
FE-B
WASHER
3' - 1
0"
12" HIGH CONC. WASHING MACHINE HOUSEKEEPING CURB
1' - 0
"
DRAIN TROUGH, SEE PLUMB. DWGS.
NEW HANDRAILS, SEE SECTION
LAUNDRY203B
SUSPENDED LIGHT FIXTURES, SEE ELEC. DWGS.
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
3
A3.1
RESILIENT BASE, RB-1
NEW BULKHEAD WITH 5/8" GWB ON 3-5/8" METAL STUDS @ 16" O.C. TO CONC. STRUCTURE ABOVE TO SEAL OFF LAUNDRY ROOM FROM OPEN CEILING SPACE
NEW STEEL HANDRAILS AND BRACKETS, PTD., BOTH SIDES. 1-1/2" O.D. STEEL PIPE WITH BRACKETS @ 4'-0" O.C. MAX. RETURN ENDS OF RAILING TO WALL, TYP.
LAUNDRY203B
STAIRST02
EXISTING SUSPENDED PLASTER CEILING TO REMAIN
NEW LIGHT FIXTURE, SEE ELEC. DWGS.
CLOSET203C
NEW ELEC. PANEL BEYOND, SEE ELEC. DWGS.
LAUNDRY ACCESS203A
1' - 0"
1' - 0"
3' - 0
"
WALL PROTECTION WP-1, SEE FINISH SCHED. AND SPECSHOLLOW METAL FRAME
STAINLESS STEEL CORNER GUARDS ON H.M. FRAME, SEE SPECS
RESILIENT BASE, RB-1
4' - 0
"
SEE 2/A3.1 FOR ADDITIONAL / TYPICAL NOTES FOR THIS AREA, O.H.
EXISTING CONC. COLUMN
3' - 0
"
4' - 0
"
SUSPENDED LIGHT FIXTURES, SEE ELEC. DWGS.
RESILIENT BASE, RB-1
HVAC DUCTWORK, SEE MECH. DWGS.
01_ATHLETIC LEVEL0' - 0"
03_ACADEMIC LEVEL15' - 4"
STAIRST02
1' - 0"
1' - 0"
NEW BULKHEAD WITH 5/8" GWB ON 3-5/8" METAL STUDS @ 16" O.C. TO CONC. STRUCTURE ABOVE TO SEAL OFF LAUNDRY ROOM FROM OPEN CEILING SPACE
EXISTING SUSPENDED PLASTER CEILING TO REMAIN
NEW STEEL HANDRAILS AND BRACKETS, PTD., BOTH SIDES. 1-1/2" O.D. STEEL PIPE WITH BRACKETS @ 4'-0" O.C. MAX. RETURN ENDS OF RAILING TO WALL, TYP.
NEW LIGHT FIXTURE, SEE ELEC. DWGS.
3' - 0
"
CLOSET203C
LAUNDRY203B
RESILIENT BASE
RESILIENT BASE
SPRINKLER LINE WALL MOUNTED BELOW EXISTING CEILING, SEE FP DWGS.COORD. FINAL LOCATION AND MOUNTING WITH A/E
01_ATHLETIC LEVEL0' - 0"
1/2"
2' - 0"
CHIP OUT 1/2" OF CONCRETE AT BASE OF RAMP TO ELIMINATE FEATHER EDGE
NEW CONCRETE RAMP
EXISTING CONCRETE SLAB
1 1/
2"
WWF 6 X 6 - W1.4 X W1.4 OVER EXISTING SLAB
01_ATHLETIC LEVEL0' - 0"
1' - 0
"
2' - 6" 3' - 6"
DRAIN TROUGH AND LINT INTERCEPTOR
WASHERS
12" HIGH WASHING MACHINE HOUSEKEEPING CURB.3000 PSI CONCRETE WITH (7) #5 REINF. BARS EACH WAY AT BOTTOM
#5 REINF. BARS, 8" LONG - DRILL AND EPOXY WITH 3" EMBEDMENT INTO EXISTING SLAB AT 12" O.C. FOR FULL PERIMETER, EXTEND 5" INTO HOUSEKEEPING CURB
KITCHEN201 LAUNDRY
203B
EXISTING WALLS
SEE PLUMB. DWGS. FOR SIZE AND CONNECTION DETAILS
RESILIENT BASE
3"
EXISTING 8" CMU WALL
CONT. SEALANT & BACKER ROD ALL SIDES
HOLLOW METAL DOOR FRAME
8 3/4"
3/8" THICK X 7" WIDE STEEL PLATE LINTEL, MIN. 6" BEARING EACH SIDE
4"
EXISTING 8" CMU WALL
CONT. SEALANT & BACKER ROD ALL SIDES
HOLLOW METAL DOOR FRAME
3/8" THICK X 7" WIDE STEEL PLATE LINTEL, MIN. 6" BEARING EACH SIDE
4"
8 3/4"
EXISTING 8" CMU WALL
CONT. SEALANT & BACKER ROD ALL SIDES
HOLLOW METAL DOOR FRAME, WRAP CMU AT JAMB
8 3/4"
2"
EXISTING 8" CMU WALL
CONT. SEALANT & BACKER ROD ALL SIDES
NON-RABBETED HOLLOW METAL DOOR FRAME, WRAP CMU AT JAMB
8 3/4"
2"
HOLLOW METAL DOOR AND FRAME
RESILIENT BASE
NEW CONCRETE LANDING AND RAMP
EXISTING CMU WALL, CUT DOWN BELOW LANDING LEVEL TO MATCH SLOPE OF RAMP IN CORRIDOR AND CONTINUE CONCRETE FROM LANDING ACROSS CMU AT SILL TO CREATE SMOOTH TRANSITION AT THRESHOLD
SLOPED CONCRETE AT SILL TO TRANSITION TO SLOPED RAMP IN CORRIDOR (HEIGHT VARIES). CHIP OUT 1/2" OF CONCRETE AT BASE OF RAMP TO ELIMINATE FEATHER EDGE
EXISTING RAMP SLAB
VARI
ES A
LONG
SLO
PE4"
AT
HIGH
POI
NT
SAW CUT JOINT AT FACE OF CMU WALL TO CONTROL CRACKING
LAUNDRY ACCESS203A
1/2"
RECESS MIN. 2X DEPTH OF RESINOUS FLOORING COATING AT TERMINATION (WIDTH OF HM FRAME TO SAWCUT)
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
1/22
/201
9 1:
01:4
0 PM
A3.1U501
.18
01.2
2.19
ELEV
ATIO
NS, S
ECTI
ONS,
PART
ITIO
N TY
PES,
DOO
RSC
HEDU
LE A
ND D
ETAI
LS
Auth
or
Chec
ker
COLI
SEUM
LAU
NDRY
EQU
IPM
ENT
RELO
CATI
ONCa
rolin
a Co
liseu
m70
1 As
sem
bly S
t.Co
lumbia
, SC
2920
8
INTERIOR PARTITION1 1/2" = 1'-0"M#A
LEGEND - PARTITION TYPES
REVI
SIO
N S
NO.
NAM
EDA
TE
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.11 HALLWAY ELEVATION - EAST
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.12 SECTION AT LAUNDRY ACCESS - E/W
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.13 SECTION AT TRASH AND LAUNDRY ACCESS - N/S
DOOR & FRAME TYPES
DOOR SCHEDULE
Mark
DOORFRAMETYPE HEAD JAMB SILL RATING REMARKSWIDTH HEIGHT
DOORTYPE
01_ATHLETIC LEVEL203AA 3' - 8" 7' - 0" D1 F1 11/A3.1 13/A3.1 15/A3.1 N/A203AB 3' - 4" 7' - 4" -- F2 12/A3.1 14/A3.1 -- N/A NO DOOR01_ATHLETIC LEVEL: 2
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.14 WEST ELEVATION - LAUNDRY
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.15 NORTH ELEVATION - LAUNDRY
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.16 EAST ELEVATION - LAUNDRY
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.17 SOUTH ELEVATION - LAUNDRY
REFERENCED ON:
1/4" = 1'-0"A3.1 A1.18 SECTION AT STAIR
REFERENCED ON:
1 1/2" = 1'-0"A3.1 A3.19 DETAIL AT BASE OF RAMP
REFERENCED ON:
3/4" = 1'-0"A3.1 A1.110 SECTION DETAIL AT WASHER CURB
REFERENCED ON:
1 1/2" = 1'-0"A3.111 HEAD DETAIL 1
REFERENCED ON:
1 1/2" = 1'-0"A3.1 A3.112 HEAD DETAIL 2
REFERENCED ON:
1 1/2" = 1'-0"A3.113 JAMB DETAIL 1
REFERENCED ON:
1 1/2" = 1'-0"A3.1 A1.114 JAMB DETAIL 2
REFERENCED ON:
1 1/2" = 1'-0"A3.1 A3.115 SILL DETAIL 1
UP
UPUP
UP
ABBREVIATION DESCRIPTION BASIS OF DESIGN
BASERB
FLOOR
WALLSP-1
CEILINGS
EXP STR
4" RUBBER COVE
PAINT--GENERAL WALL COLOR
EXPOSED STRUCTURE, DUCTS, PIPES
JOHNSONITE RECESS WALL BASE, COLOR: #63 BURNT UMBER
SEMI-GLOSS, TO MATCH SW#7632 MODERN GRAY
NO NEW FINISH
MISC.
P-3 PAINT-HM FRAMES, 'MED TONE,' SEMI-GLOSSP-2 PAINT-CEILINGS, 'WHITE TONE,' FLAT FLAT--TO MATCH SW # 7005 PURE WHITE
P-5 PAINT- DOORS/HANDRAIL, ACCENT-'DARK GREY' SEMI-GLOSS TO MATCH 'DARK GREY' EXISTING DOORS--SW #7068 GRIZZLE GRAY OR EQ.
SEMI-GLOSS--'TAUPE' TO MATCH EXISTING ADJACENT FRAMES, SW#7507 STONE LION OR EQ.
QUARRY TILE- 6"x6"QT
EXISTING CONCRETE, SPECIAL COATINGEX CONC/SPC SHERWIN WILLIAMS, FASTOP12S BROADCAST 46 GRIT ALUMINUM OXIDE, OR APP'D EQ., COLOR: GRAY
TO MATCH EXISTING--DALTILE GOLDEN BROWN OR GRAY--FIELD VERIFY, GROUT: LATICRETE #60 DUSTY GREY
WP WALL PROTECTION PANEL, 4'-0 WIDTH X 8 OR 10' LENGTHS, COLOR: CHARCOAL--SEE SPEC.WALL PROTECTION
CG CORNER GUARD, STAINLESS STEEL 4' H X 2" RETURN, STAINLESS STEEL CORNER GUARDS, SEE FINISH PLAN FOR LOCATION
EXB EXISTING BASE BLOCK OR CONCRETE, NO NEW BASE
BROADLOOM CARPET CPT PATCRAFT, CLOISONNE II, COLOR: #32527 ALTROUS
P-4 PAINT- PRIMARY ACCENT-'GARNET' SEMI-GLOSS-TO MATCH USC CUSTOM GARNET --MATCH ARCHITECT'S SAMPLE SW# CCE 02 32 64 128
REFERENCE SPEC. SECTION
096513
096816099600
099123099123099123099123099123102650
102650
GB/P-* GYPSUM WALL BOARD - PAINTED SEE COLOR DESIGNATIONS ABOVE 102650
EXISTINGEX NO NEW FINISH
RM RESILIENT MOULDING MOULDING ACCESSORY @ TRANSITION FROM CPT TO ADJACENT SURFACE - COLOR TO MATCH BASE, SEE SPEC. 096513
093000
LAUNDRY203B
LAUNDRY ACCESS203A
STAIRST02
1
2
2
1
WASHERDRYERFUTURE WASHERWASHERDRYERDRYERDRYERDRYER
DRAIN TROUGH
FOOD SERVICE201D
KITCHEN201
4
3
5
CLOSET203C
TRASH203
6
7
WHERE SPECIFIC PRODUCTS ARE INDICATED, ITEM DESIGNATION INCORPORATES QUALITY AND AESTHETIC APPEARANCE FOR 'BASIS OF DESIGN.' SEE SPECIFICATIONS FOR EQUAL MANUFACTURER'S PER PRODUCT TYPE INDICATED. DEPENDING ON LOCATION OF ITEM, ALTERNATES SHALL MATCH IN COLOR/ TEXTURE, AS WELL AS PERFORMANCE CRITERIA, PER ARCHITECT'S APPROVAL.
ALL PAINT COLOR SELECTIONS SHALL BE FIELD VERIFIED WITH ARCHITECT IN LIGHTED CONDITIONS PRIOR TO FINAL INSTALLATION, SEE SPEC. RE: MOCK-UPSSEE FINISH PLANS FOR FLOOR MATERIAL TRANSITIONS AT DOOR THRESHOLDS AND IN OPEN FLOOR AREAS.
REFERENCE REFLECTED CEILING PLANS FOR EXTENT/LOCATION OF CEILING FINISH DESIGNATIONS AND HEIGHTS.
SEE FINISH PLANS AND/OR ENLARGED INTERIOR PLANS & ELEVATIONS FOR EXTENT OF SPECIFIC FINISH DESIGNATIONS.
FINISH COLUMNS IN OPEN AREAS TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE.
SEE SILL DETAILS, FLOORING SPECIFICATIONS AND FINISH SCHEDULE FOR TRANSITION STRIPS.
SEE SPECS FOR FLOOR AND WALL PREP FOR ALL NEW FINISHES.
A.
B.
C.
D.
E.
F.
G.
1 CORNER GUARD LOCATION, SEE SPECS.
EXTENT OF WALL PROTECTION, WP, INSTALLED FROM FINISH FLOOR TO 4'-0" A.F.F. @ LAUNDRY; 3'-0" @ ENTRY, SEE ELEV. 7/A3.1
PAINT WALLS TO DECK ABOVE TO GREATEST EXTENT POSSIBLE. CLEAN EXPOSED CEILING PIPES, DUCTS, ETC. --DO NOT PAINT.
PAINT HANDRAILS: P-5
REPLACE QUARRY TILE AREA, AS NEEDED, PER DEMO REPAIR
RESILIENT BASE @ NEW WALL
PAINT FOOD SERVICE SIDE OF NEW CMU INFILL TO MATCH EXISTING PAINT COLOR AND INFILL BASE TO MATCH EXISTING.
2
3
4
5
6
7
EX/NEW CONCRETE WITH INDUSTRIAL NON-SLIP COATING, 'SPC'
CARPET, 'CPT'
QUARRY TILE REPLACEMENT, 'QT'
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
1/22
/201
9 1:
01:4
2 PM
A4.1U501
.18
01.2
2.19
FINI
SHES
Auth
or
Chec
ker
COLI
SEUM
LAU
NDRY
EQU
IPM
ENT
RELO
CATI
ONCa
rolin
a Co
liseu
m70
1 As
sem
bly S
t.Co
lumbia
, SC
2920
8
SCHEDULED INTERIOR FINISHESREFERENCED
ON:1/4" = 1'-0"A4.1 A3.1
1 FINISH PLAN
ROOM FINISH SCHEDULE (FINISH ORIENTATION IS PLAN NORTH)
Number NameBaseFinish Floor Finish NORTH EAST SOUTH WEST Ceiling Finish
201 KITCHEN EX EX, QT EX EX EX EX EX203 TRASH RB EX EX EX P-1 EX EX203A LAUNDRY ACCESS RB CONC/SPC WP,P-1 P-1 WP,P-1 WP,P-1 GB/P-2203B LAUNDRY RB EX
CONC/SPCP-4 P-1 P-1 P-1 EXP STR
203C CLOSET RB CPT EX EX EX EX EXST02 STAIR RB CPT P-1 P-1 P-1 P-1 GB/P-2
REVI
SIO
N S
NO.
NAM
EDA
TE
GENERAL NOTES - INTERIOR FINISHES KEYNOTES - FINISHES
LEGEND - FLOOR FINISHES
UPUP
UP
1 1
2
2
2
2
2
3
4
1
1
EXISTING EXHAUST LOUVER TO REMAIN
EXISTING INTAKE LOUVER ABOVE DOOR TO REMAIN
EXISTING EXHAUST DUCTWORK TO REMAIN
EXISTING EXHAUST DUCTWORK TO REMAIN
DEMOLITION NOTES
REMOVE SUSPENDED CHILLED WATER FAN COIL UNIT COMPLETE INCLUDING SUPPLY AND RETURN PIPING BACK TO MAINS, DRAIN PIPING, HANGERS, WIRING, CONTROLS, ETC.
REMOVE ABANDONED SUPPLY DUCT AND ASSOCIATED DIFFUSERS AS SHOWN.
REMOVE SIDEWALL TRANSFER GRILLE.
REMOVE CEILING EXHAUST GRILLE AND ASSOCIATED RUNOUT DUCT BACK TO TRUNK.
1
2
3
4
REGISTERED
PROFES
SI O
N A L E N G I N E E R
B R A D L E YJ.
JASINSKI
SOUTHCA
R OL I N A
No. 2
3877
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected] MD1.1U5
01.1
8
01.1
6.19
HVAC
DEM
OLIT
ION
FLOO
R PL
ANBJ
J
BJJ
COLI
SEUM
LAU
NDRY
REL
OCAT
ION
Caro
lina
Colis
eum
701
Asse
mbly
St.
Colum
bia, S
C 29
208
1−22−19
1/4" = 1'-0"MD1.11 DEMOLITION FLOOR PLAN
REVI
SIO
N S
NO.
NAM
EDA
TE
UPUP
UP
TRASH203
LAUNDRYACCESS
203A
LAUNDRY203B
FOODSERVICE
201D
2M1.1
3M1.1
EDH-1
RELOCATEDAHU
DBF-1PROVIDE 22"x22" COUNTER BALANCED RELIEF DAMPER WITH FLANGE FRAME AND CONCRETE GRAY HI-PRO POLYESTER COATING
EXISTING EXHAUST LOUVER TO REMAIN
EXISTING INTAKE LOUVER ABOVE DOOR TO REMAIN
CLEAN EXISTING DUCTWORK PRIOR TO CONNECTION TO NEW
EDH-2
21ø
21ø
17ø 15ø 12ø 8ø
24x24
24x18
MIN
. 10'-
0"
24x2
4
24x2424x18
A 1000
A 1000
A 1000
B 500
D
CHWSCHWR
D
D
D D
¾"
¾"
FIELD INSTALL DRAIN CONNECTION ON DRYER BOOSTER FAN AND PROVIDE CONDENSATE TRAP
1"DROP DRAIN LINE DOWN TIGHT TO WALL AND OVER TO CONNECT INTO TOP OF LINT TROUGH; COORDINATE WITH PLUMBING CONTRACTOR
DUCT OFFSETS UP
21ø
2"
CONNECT TO EXISTING 4" CHILLED WATER SUPPLY AND RETURN LINES ABOVE CEILING; FIELD VERIFY EXACT LOCATION AND SERVICE
1
2 2 2 2 2
T HFRESH AIR DUCT ROUTED EXPOSED WITH INTERNAL INSULATION
SUPPLY AIR DUCT ROUTED EXPOSED WITH INTERNAL INSULATION
UNIT CLEARANCE
DBF-1
21ø
21ø 17ø 15ø 12ø 8ø
CLEANOUT45° CONNECTION (TYP.)
D
8ø 8ø 8ø 8ø 8ø
21ø
LAUNDRY203B
TRASH203
RELOCATEDAHU
EDH-1 EDH-2
18x24 18x2424x2424x24
LAUNDRY203B
LAUNDRYACCESS
203A
ELECTRICAL202
RENOVATION NOTES
INSTALL EXISTING RELOCATED AIR HANDLING UNIT AS DETAILED. PROVIDE NEW PIPING SPECIALTIES AS REQUIRED. THIS CONTRACTOR IS RESPONSIBLE FOR MOVING THE UNIT FROM ITS CURRENT LOCATION WITHIN THE COLISEUM. PRIOR TO INSTALLATION REMOVE THE DYNAMIC AIR CLEANING FILTERS AND ASSOCIATED WIRING AND TEAR DOWN AND CLEAN ALL INTERIOR SURFACES, COOLING COIL, AND FAN.
PROVIDE 12" LONG SECTION OF 8"ø ALUMINUM FLEXIBLE DRYER DUCT AND CONNECT TO APPLIANCE WITH WORM CLAMPS.
1
2
REGISTERED
PROFES
SI O
N A L E N G I N E E R
B R A D L E YJ.
JASINSKI
SOUTHCA
R OL I N A
No. 2
3877
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected] M1.1U5
01.1
8
01.1
6.19
HVAC
REN
OVAT
ION
FLOO
R PL
ANBJ
J
BJJ
COLI
SEUM
LAU
NDRY
REL
OCAT
ION
Caro
lina
Colis
eum
701
Asse
mbly
St.
Colum
bia, S
C 29
208
1−22−19
1/4" = 1'-0"M1.11 RENOVATION FLOOR PLAN
1/4" = 1'-0"M1.12 DRYER VENTING SECTION
1/4" = 1'-0"M1.13 AIR HANDLING UNIT SECTION
REVI
SIO
N S
NO.
NAM
EDA
TE
GENERAL NOTES
VISIT SITE PRIOR TO BIDDING. THIS CONTRACTOR SHALL DETERMINE DIFFICULTY OF INSTALLATION AND REFLECT THIS IN HIS BIDDING.
DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS AND REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF DOORS, WINDOWS, AIR DISTRIBUTION, ETC.
THIS CONTRACTOR SHALL VERIFY ALL EXISTING ITEMS AND LOCATIONS IN THE FIELD.
ALL PIPING AND DUCTWORK LOCATIONS SHALL BE COORDINATED WITH WORK UNDER OTHER DIVISIONS OF THE SPECIFICATIONS TO AVOID INTERFERENCE.
EXISTING PIPE, DUCTWORK, CONDUIT, ETC. THAT INTERFERES WITH THE ROUTING OF NEW SYSTEMS SHALL BE RELOCATED. THIS CONTRACTOR SHALL INCLUDE THE COST OF SUCH IN HIS BID UNLESS NOTED OTHERWISE.
WATER SYSTEMS SHALL BE DRAINED AS REQUIRED FOR INSTALLATION OF WORK. UPON COMPLETION, SYSTEM SHALL BE FILLED WITH WATER AND VENTED OF ALL AIR.
ALL PIPING AND DUCTWORK INSULATION SHALL BE RUN CONTINUOUSLY THROUGH PARTITIONS.
ALL PIPING IS SHOWN DIAGRAMMATIC. HOWEVER, THIS CONTRACTOR SHALL PROVIDE ALL REQUIRED FITTINGS, PIPING AND INSULATION FOR ALL OFFSETS AND/OR CHANGES IN ELEVATION.
EXTEND ALL DRAIN LINES TO NEAREST FLOOR DRAIN OR AS INDICATED – SO ROUTED AS TO AVOID INTERFERENCE WITH PASSAGEWAYS AND MAINTENANCE. DRAINS FROM AIR HANDLING UNITS SHALL BE TRAPPED PER STATIC PRESSURE REQUIREMENTS.
ALL WATER PIPING SHALL PITCH DOWN IN DIRECTION OF FLOW ONE-INCH PER FIFTY FEET WITH MANUAL AIR VENTS AT ALL HIGH POINTS AND 3/4-INCH DRAIN VALVES WITH STANDARD HOSE CONNECTION AT ALL LOW POINTS.
ALL VALVES AND SPECIALTIES SHALL BE LINE SIZE UNLESS NOTED OTHERWISE, USING ECCENTRIC REDUCERS ON AUTOMATIC VALVES AS REQUIRED.
MINIMUM PIPE SIZE SHALL BE 3/4-INCH UNLESS INDICATED OTHERWISE.
ALL PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATIONS AND FURTHER SUPPORTS OR HANGERS SHALL BE PROVIDED TO PREVENT WEIGHT OF PIPING BEING PLACED ON EQUIPMENT.
ALL DUCTWORK SPECIFIED TO BE LINED SHALL BE INCREASED IN SIZE TO ALLOW FOR LINER.
PROVIDE FOR ACCESS TO ALL EQUIPMENT REQUIRING CLEANING OR ADJUSTMENT PER MANUFACTURER’S INSTRUCTIONS. PROVIDE FULL SPACE FOR COIL REMOVAL AND REPLACEMENT FOR ALL CHILLED WATER AIR HANDLING UNITS.
THIS CONTRACTOR SHALL PROVIDE ALL ITEMS OF MISCELLANEOUS STEEL AS REQUIRED FOR INSTALLATION OF ALL MECHANICAL ITEMS.
THIS CONTRACTOR SHALL DO ALL CONTROL WIRING. DIVISION 26 WILL DO ALL POWER WIRING. ALL WIRING SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. CONTROL WIRING SHALL BE CONCEALED WITHIN WALL AND ALL CONTROL WIRING SHALL BE ROUTED IN EMT CONDUIT. DUCT DETECTORS PROVIDED BY DIVISION 26 SHALL BE INSTALLED BY DIVISION 23. POWER WIRING AND FIRE ALARM CONNECTIONS SHALL BE BY DIVISION 26. CONTROL WIRING FOR UNIT SHUTDOWN SHALL BE BY DIVISION 23.
LOCATE ALL SPACE CONTROL INSTRUMENTS 4'-0" ABOVE FINISHED FLOOR TO TOP OF DEVICE IN ACCORDANCE WITH ADA. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS TO AVOID ITEMS INCLUDING BUT NOT LIMITED TO CUSTOM FINISHES, FIXED CASEWORK, FURNITURE, AND DOOR SWINGS. IN THE EVENT OF CONFLICTS IN THE FIELD, THE CONTRACTOR SHALL BRING THIS TO THE ATTENTION OF THE A/E FOR FINAL APPROVAL OF LOCATION.
INSTRUMENT TEST HOLES SHALL BE LOCATED IN EACH SUPPLY DUCT OR ZONE DUCT, IN EACH RETURN AIR DUCT AND EACH OUTSIDE AIR DUCT.
CORRECT SETTINGS ON ALL BALANCING FITTINGS SHALL BE PERMANENTLY MARKED. PROVIDE ORANGE FLAGGING RIBBON ON EACH DAMPER HANDLE FOR EASY IDENTIFICATION.
THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY DISMANTLING OF EQUIPMENT TO BE REMOVED.
ITEMS REMOVED UNDER THIS CONTRACT SHALL BECOME THE PROPERTY OF THE CONTRACTOR, UNLESS NOTED OTHERWISE, AND SHALL BE DISPOSED OF PROPERLY.
THE HVAC SYSTEMS SHALL NOT BE OPERATED DURING HEAVY CONSTRUCTION OPERATIONS INCLUDING MASONRY, GYPSUM BOARD SANDING, HEAVY CLEANUP ACTIVITIES, OR OTHER ACTIVITIES THAT CREATE AIRBORNE PARTICLES OR DEBRIS. ALL SYSTEMS SHALL BE CLEAN OF CONSTRUCTION DEBRIS, DUST AND DIRT AT FINAL COMPLETION. DUCT CLEANING AND UNIT/COIL CLEANING SHALL BE PERFORMED AS REQUIRED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
TAG
AIRFLOW
CFM AIR-CFM
ESP
IN. WG
BRAKE
H.P.
MOTOR
H.P.MODEL NO.
OUTDOORTRANE
BCHC090G2EX AHU 3,0003,000 0.5 2.4 3
COOLING COIL
WTR. P.D.
FT. WTR.
MAX-FPMEADB/WB LADB/WB GPM REMARKS
95.0/78.0 56.7/56.6 42.0 37.9 500 1
EXISTING RELOCATED AIR HANDLING UNIT (FOR INFORMATION ONLY)
1. PROVIDE NEW 2" THICK MERV 8 PLEATED FILTERS IN PLACE OF EXISTING DYNAMIC AIR CLEANER FILTERS. FIELD VERIFY SIZES AND QUANTITIES.
VALVEDRAIN
CH
WR
CH
WS
¾" GATE VALVE AND MALE HOSECONNECTION
PT PORT (TYPICAL)
MODULATING PI 2-WAY CONTROL VALVE
EXTEND AND CONNECT TO EXISTING 4" LINES
SHUT-OFF VALVE(TYPICAL)
Y-STRAINER WITHBLOWDOWN(TYPICAL)
MANUAL AIR VENT(TYPICAL)THERMOMETER(TYPICAL)
UNION (TYPICAL)
COOLINGCOIL
2" 2"
BE SIZED BY THE SEISMIC RESTRAINT SUPPLIER.ANCHOR BOLTS FOR NON-ISOLATED AND INTERNALLY ISOLATED EQUIPMENT SHALL1.
UNITS (SUSP.)AIR HANDLING
TAGEQUIPMENT ISOLATION
MANUFACTURERINTERNAL BY1.0
COMPONENTIp SPECIFICATION
SPEC SCNOTE 1
SEISMIC REST.SPECIFICATION
2"
DEFLECTIONISOLATION
RISK CATEGORY = III SEISMIC DESIGN CATEGORY = D
1.0 SPEC D SPEC SC 1"INLINE FANS
ISOLATION AND SEISMIC SCHEDULE
100A
CO2
LEGEND
,
CHWR
CHWS
D
/
/
T
H
ZONE TEMPERATURE SENSOR
TYPE "A" DIFFUSER, 100 CFM
SHUTOFF VALVE
PIPE TURNS TO, AWAY
SYMBOL
ECCENTRIC REDUCER
CONCENTRIC REDUCER
DESCRIPTION
CHILLED WATER SUPPLY LINE
CHILLED WATER RETURN LINE
DRAIN LINE
THERMOMETER / PRESSURE GAGE
THERMOMETER WELL CAPPED / GAGE COCK
UNION
STRAINER WITH BLOWDOWN
MBD MANUAL OPPOSED BLADE BALANCING DAMPER
RELATIVE HUMIDITY SENSOR
CARBON DIOXIDE SENSOR
48"x24" RECTANGULAR DUCT
RETURN AND FRESH AIR DUCTWORK
RECTANGULAR SUPPLY DUCTWORK
48x24
LOUVERED DOOR BY GENERAL CONTRACTOR
CONNECTION POINT OF NEW TO EXISTING
ABOVE FINISHED FLOORAFF
EXHAUST DUCTWORK
B
TAG
A
NECK SIZE
SIDEWALL SUPPLY
DESCRIPTION
PRICE
MANUFACTURER
620D
MODEL
SURFACE
FRAME
1,000
CFM
24"x16"
MAX NC
3526"x18"
FACE SIZE REMARKS
1,2,3
AIR DISTRIBUTION SCHEDULE
1. PROVIDE WITH STANDARD WHITE FINISH.2. PROVIDE ALUMINUM CONSTRUCTION.3. PROVIDE WITH OPPOSED BLADE BALANCING DAMPER.
SIDEWALL EXHAUST PRICE 630D SURFACE 500 14"x10" 3516"x12" 1,2,3
DBF-1
TAG
EQD-15-VG
GREENHECKMODEL NO.
INLINE
TYPE
3,750
CFM
2
MOTORH.P./W.
0.5
ESP
17
SONES(MAX.)
1,2
REMARKS
DRYER BOOSTER FAN SCHEDULE
1. PROVIDE DIRECT DRIVE MIXED FLOW INLINE FAN WITH DISCONNECT SWITCH, CONCRETE GRAY PERMATECTOR COATING, DUCT COLLARS, AND FOUR BOLTED ACCESS DOORS.
2. PROVIDE VARI-GREEN EC MOTOR WITH CONSTANT PRESSURE CONTROL AND INTEGRAL TRANSDUCER.
3/8"ø (TYPICAL FOR 6)
NORMALLY CLOSEDBALL VALVE
FLOAT SWITCH1-1/2"x1-1/2"x1/4"ANGLE IRON
BOLT & LOCK WASHERBOTH SIDES
22 GAUGE GALVANIZED DRAINPAN 3" LARGER THAN AHUON ALL SIDES, 3" DEEP
SEISMIC RESTRAINT CABLEAT 45 DEGREE ANGLESSECURED TO STRUCTURETYPICAL FOR 4 CORNERS
SUSPENDED FROMSTRUCTURE ABOVE
STRUCTURE
AIR HANDLINGUNIT
4" BASE RAIL
DRAIN TRAP PER DETAIL
EXTEND TO NEAREST FLOOR DRAIN
H
H = FAN INLET PRESSURE (IN. W.C.) + 1"
H/2 MIN.
FROM COILPAN
HAND-TIGHT THREADED CLEANOUT PLUG (TYP.)
FAN INLET PRESSURE (NEGATIVE)
HVAC EQUIPMENT
EXTEND TO FLOOR DRAIN
WATER SEAL
ELECTRIC DUCT HEATER SCHEDULE
EDH-1
TAGDUCT SIZE
MODEL
HF SERIES
MARKELSTAGES
33
KW
3
REMARKS
24"x24"
(WxH)
1,2
1. PROVIDE WITH DOOR INTERLOCKING DISCONNECT SWITCH.2. PROVIDE WITH SCR CONTROLS, CONTROL TRANSFORMER, AIR FLOW SWITCH AND HIGH LIMIT
SWITCH.
EDH-2 HF SERIES 19 2 24"x18" 1,2
REGISTERED
PROFES
SI O
N A L E N G I N E E R
B R A D L E YJ.
JASINSKI
SOUTHCA
R OL I N A
No. 2
3877
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected] M2.1U5
01.1
8
01.1
6.19
HVAC
DET
AILS
, NOT
ES,
SCHE
DULE
S, A
ND L
EGEN
D
BJJ
WCL
COLI
SEUM
LAU
NDRY
REL
OCAT
ION
Caro
lina
Colis
eum
701
Asse
mbly
St.
Colum
bia, S
C 29
208
1−22−19
NO SCALEM2.11 AHU PIPING DETAIL
NO SCALEM2.12 AIR HANDLING UNIT SUPPORT DETAIL
NO SCALEM2.13 CONDENSATE DRAIN DETAIL
REVI
SIO
N S
NO.
NAM
EDA
TE
UPUP
UP
1
DEMOLITION NOTES
EXISTING ELECTRIC WATER COOLER TO BE REMOVED COMPLETE. CAP EXISTING WASTE AND SUPPLY PIPING IN WALL.
1
REGISTERED
PROFES
SI O
N A L E N G I N E E R
T O D DF .
SWYGERT
SOUTHCA
R OL I N A
No. 1
5574
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected] PD1.1U5
01.1
8
01.1
6.19
DEM
OLIT
ION
PLAN
DEM
TFS
COLI
SEUM
LAU
NDRY
REL
OCAT
ION
Caro
lina
Colis
eum
701
Asse
mbly
St.
Colum
bia, S
C 29
208
1−22−19
1/4" = 1'-0"PD1.11 DEMOLITION PLAN
REVI
SIO
N S
NO.
NAM
EDA
TE
UPUP
UP
UPUP
UP
TRASH203
LAUNDRYACCESS
203A
LAUNDRY203B
FOODSERVICE
201D
SD
SD SD SD
ELECTRICAL202
STAIRST01
FOODSTORAGE
201C KITCHEN201
STAIRST02
CLOSET203C
LT
2
1
2
FD
4"
2"
DROP DOWN BELOWSLAB
2" VENT UP TIGHTTO WALL
NOTE:ALL VENT PIPING SHALLBE 2" IN SIZE UNLESSOTHERWISE INDICATED.
4"
FUTUREWASHERDRAIN
TRASH203
LAUNDRYACCESS
203A
LAUNDRY203B
FOODSERVICE
201D
CLOSET203C
STAIRST02
KITCHEN201
FOODSTORAGE
201C
ELECTRICAL202
STAIRST01
1"
3
4
1"
¾"
5 5
NOTE:ALL SUPPLY PIPING TOBE ROUTED ABOVECEILING UNLESSOTHERWISE INDICATED.
"A" "A" "A""A"
NOTE:THE OWNER HAS INDICATEDHAZARDOUS MATERIAL ATMASTIC JOINTS OF EXISTINGPIPE INSULATION. CONTRACTORSHALL CONTACT OWNER PRIORTO MAKING ANY CONNECTIONS,BUT AFTER CONTRACTOR HASDETERMINED EXACT LOCATIONS.
NOTES TO SHEET
EXTEND AND CONNECT TO NEAREST SANITARY VENT LINE IN CHASE. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR CEILING REMOVAL AND REPLACEMENT IN EXISTING KITCHEN AREA AS REQUIRED.
PROVIDE INDIRECT DRAIN FROM WASHER TO LINT INTERCEPTOR. SUPPORT LINES WITH STANDOFF BRACKETS FROM FLOOR.
CONNECT TO EXISTING 1" DOMESTIC COLD WATER LINE ABOVE CEILING AT THIS APPROXIMATE LOCATION.
CONNECT TO EXISTING 1¼" DOMESTIC COLD WATER LINE ABOVE CEILING AT THIS APPROXIMATE LOCATION.
DOWN TIGHT TO WALL AND TERMINATE WITH THREADED HOSE VALVE WITH WHEEL HANDLE AT 4'-0" ABOVE FINISHED FLOOR.
1
2
3
4
5
PLUMBING FIXTURE SCHEDULE
P. NO.
MIN. SUPPLY
CWNAMEFIXTURE MFGR. MFGRS. NO. SIZE HW REMARKS
FD - -- - -FLOOR DRAIN ZURN ZN-415-S - - - - - WITH 5"x5" NICKLE BRONZE STRAINER, P-TRAP, AND PROSET, OR APPROVED EQUAL, TRAP GUARD.
LT - -- - -LINT TROUGH H-M COMPANY 120 48"x18"x12" - - WITH LINT FILTER AND 4" END DRAIN OUTLET.
GENERAL NOTESALL WORK SHALL BE PERFORMED ACCORDING TO ALL LOCAL, STATE, NATIONAL CODES, AND THE 2015 INTERNATIONAL PLUMBING CODE.
DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS, FIXTURE LOCATIONS, ETC. EXCEPT WHERE PIPE SPACE IS PROVIDED OR UNLESS NOTED OTHERWISE, ALL SUPPLY, WASTE AND VENT RISERS SHALL BE RUN IN WALLS AND PARTITIONS.
COORDINATE CLOSELY WITH ALL WORK DONE UNDER OTHER DIVISIONS OF THE SPECIFICATIONS TO AVOID INTERFERENCE AND CONFLICT. PROVIDE FOR ACCESS TO ALL EQUIPMENT REQUIRING CLEANING OR ADJUSTMENT.
ALL PIPING INSULATION SHALL BE RUN CONTINUOUSLY.
REMOVAL AND REPLACEMENT OF CEILING, AS REQUIRED FOR INSTALLATION OF NEW WORK, SHALL BE DONE BY THIS CONTRACTOR. ANY CEILING GRID OR TILE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT NO COST TO THE OWNER.
1.
2.
3.
4.
5.
6.
7.
LEGEND
DOMESTIC COLD WATER LINE
DOMESTIC HOT WATER LINE
SANITARY WASTE LINE
SANITARY VENT LINE
SHUTOFF VALVE
PIPE TURNS TO, AWAY,
SYMBOL DESCRIPTION
EXISTING STORM DRAIN LINESD
CONNECTION POINT OF NEW TO EXISTING
"A" SHOCK ARRESTOR (P.D.I. RATING OF "A")
REGISTERED
PROFES
SI O
N A L E N G I N E E R
T O D DF .
SWYGERT
SOUTHCA
R OL I N A
No. 1
5574
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G AN
D TH
E DE
SIGN
TH
EREO
N AR
E TH
E PR
OPER
TY O
F TH
E GA
RVIN
DES
IGN
GROU
P, IN
C.
THE
REPR
ODUC
TION
, COP
YING
, OR
USE
OF T
HIS
DRAW
ING
WIT
HOUT
TH
E W
RITT
EN C
ONSE
NT O
F TH
E GA
RVIN
DES
IGN
GROU
P IS
PR
OHIB
ITED
AND
ANY
IN
FRIN
GEM
ENT
WIL
L BE
SUB
JECT
TO
LEG
AL A
CTIO
N.
@20
03 G
ARVI
N DE
SIGN
GRO
UP, I
NC.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected] P1.1U5
01.1
8
01.1
6.19
FLOO
R PL
ANS,
NOT
ES, S
CHED
ULE,
AND
LEGE
ND
DEM
TFS
COLI
SEUM
LAU
NDRY
REL
OCAT
ION
Caro
lina
Colis
eum
701
Asse
mbly
St.
Colum
bia, S
C 29
208
1−22−19
1/4" = 1'-0"P1.11 FLOOR PLAN
WASTE AND VENT PIPING
1/4" = 1'-0"P1.12 FLOOR PLAN
SUPPLY PIPING
REVI
SIO
N S
NO.
NAM
EDA
TE
UPUP
UP
TRASH203
LAUNDRYACCESS
203A
LAUNDRY203B
FOODSERVICE
201D
FOODSTORAGE
201C
KITCHEN201
ELECTRICAL202
STAIRST01
STAIRST02
CLOSET203C
1
2
F F
33
SCOPE OFWORK
F
5
4
GENERAL NOTESSUBMIT DRAWINGS INDICATING EXACT LOCATION OF ALL SPRINKLER HEADS FOR OWNER'S REVIEW AND BRING ALL FIELD CONFLICTS AND REQUIRED ADJUSTMENTS TO THE OWNER'S ATTENTION FOR VERIFICATION OF FINAL LOCATION OF ALL SPRINKLER HEADS.
SPRINKLER DRAWINGS PROVIDED ARE TO ASSIST THE CONTRACTOR. SUCCESSFUL CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF A COMPLETE SYSTEM PER THESE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH ALL APPLICABLE CODES. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMISSION TO THE OFFICE OF THE STATE FIRE MARSHAL.
THE DESIGN TEAM, TO INSURE COMPATIBILITY WITH THE BUILDING DESIGN INTENT, WILL CAREFULLY REVIEW SPRINKLER PLANS. CORRECTIONS WILL BE MADE BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER.
ALL NEW SPRINKLER HEADS SHALL BE CENTERED IN ALL ACOUSTICAL CEILING TILES OR CENTERED IN GYPSUM BOARD SOFFITS AS REQUIRED.
SPRINKLER PIPING SHALL BE INSTALLED TO MEET SEISMIC REQUIREMENTS WITH LATERAL SWAY BRACING, LONGITUDINAL SWAY BRACING, AND FOUR-WAY BRACING AS REQUIRED BY NFPA AND THE INTERNATIONAL BUILDING CODES.
ALL PIPING 2-1/2" AND LARGER SHALL BE SCHEDULE 10 STEEL PIPING AND ALL PIPING SMALLER THAN 2-1/2" SHALL BE SCHEDULE 40 STEEL PIPING.
1.
2.
3.
4.
5.
6.
SPECIAL NOTES
EXISTING SPRINKLER SYSTEM SHALL BE EXTENDED OVER TO UNPROTECTED AREA INSIDE "SCOPE OF WORK" LINE AND PROVIDE COVERAGE AT NEW CEILINGS TO PROVIDE A FULLY PROTECTED AREA. PROTECTION ABOVE CEILING NOT REQUIRED.
AREA OF LAUDRY ACCESS H120E HAS SPRINKLERS INSTALLED AT STRUCTURE LEVEL. FIRE SPRINKLER CONTRACTOR TO EXTEND HEADS DOWN TO NEW CEILING. EXISTING SPRINKLERS TO REMAIN IN PLACE.
EXISTING SPRINKLER SYSTEM TO BE EXTENDED INTO NEW LAUNDRY. VERIFY HYDRAULIC SIZES.
DROP NEW SPRINKLER LINE BELOW CEILING FOR PROTECTION OF STAIRS.
NEW FIRE SPRINKLER LINE AT STAIR TO BE ROUTED EXPOSED AND MOUNTED TO WALL NEAR CEILING.
1
2
3
4
5
NOTE:ALL WORK SHALL COMPLY WITHNFPA 13 - 2013 EDITION FOR AWET PIPE SYSTEM.
ORDINARY HAZARD - GROUP I-
LIGHT HAZARD
LEGEND
-
WATER FLOW INFORMATION
INFORMATION PROVIDED BY JASON A.SHAW, P.E. WITH THE CITY OF COLUMBIA (803-545-3400).
STATIC: 89 PSIRESIDUAL: 70 PSIFLOW: 1560 GPMDATE: 8/3/2018
REGISTERED
PROFES
SI O
N A L E N G I N E E R
T O D DF .
SWYGERT
SOUTHCA
R OL I N A
No. 1
5574
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PRO
JEC
T N
O.
DAT
E
DRAWING NO.
DR
AWN
BY:
CH
ECK
ED B
Y:
THIS
DRA
WIN
G A
ND T
HE D
ESIG
N TH
EREO
N AR
E TH
E PR
OPE
RTY
OF
THE
GAR
VIN
DESI
GN
GRO
UP, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
USE
OF
THIS
DRA
WIN
G W
ITHO
UT
THE
WRI
TTEN
CO
NSEN
T O
F TH
E G
ARVI
N DE
SIG
N G
ROUP
IS
PRO
HIBI
TED
AND
ANY
INFR
ING
EMEN
T W
ILL
BE S
UBJE
CT
TO L
EGAL
ACT
ION.
@20
03 G
ARVI
N DE
SIG
N G
ROUP
, INC
.
PRO
JEC
T TI
TLE
A/E
SEAL
A/E
SEAL
DR
AWIN
G T
ITLE
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected] FP1.1U5
01.1
8
01.1
6.19
FLOO
R PL
AN A
ND N
OTES
DEM
TFS
COLI
SEUM
LAU
NDRY
REL
OCAT
ION
Caro
lina
Colis
eum
701
Asse
mbl
y St.
Colu
mbi
a, S
C 29
208
1−22−19
1/4" = 1'-0"FP1.11 FLOOR PLAN
RE V
ISIO
N S
NO
.NA
ME
DAT
E
UP
UP
UP UP
UP
UP
ELECTRICAL SYMBOL LEGEND
DESCRIPTIONSYMBOL SYMBOL
SINGLE RECEPTACLE (WALL MOUNTED @ 18"AFF)
DUPLEX RECEPTACLE (WALL MOUNTED @ 18"AFF)
PHONE OR DATA OUTLET (WALL MOUNTED @ 18"AFF)
MOTOR CONNECTION (AS NOTED)
J JUNCTION BOX (WALL MTD)
J JUNCTION BOX (FLOOR MOUNTED)
DUPLEX RECEPTACLE (FLOOR MOUNTED)
QUADPLEX RECEPTACLE (FLOOR MOUNTED)
DISCONNECT SWITCH, (REFER TO EQUIPMENT
CONNECTION SCHEDULE)
DISCONNECT SWITCH, (NON PROTECTED)
SP SPEAKER (CEILING MOUNTED)
SP SPEAKER (WALL MOUNTED)
DUPLEX RECEPTACLE (CEILING MOUNTED)
QUADPLEX RECEPTACLE (CEILING MOUNTED)
TV TELEVISION / CATV OUTLET (WALL MOUNTED @ 18"
AFF)
R SECURITY CARD READER
S SMOKE DETECTOR (WALL MOUNTED)
D SMOKE DETECTOR (DUCT MOUNTED)
A FIRE ALARM AUDIBLE DEVICE (WALL MOUNTED @ 7'-
6" AFF)
WF Wi-Fi ACCESS POINT (CEILING MOUNTED)
AIUADDRESSABLE INTERFACE UNIT (MONITOR OR
CONTROL TYPE)
HANDHOLEHH
DESCRIPTION
FSD FIRE / SMOKE DAMPER
W CCTV CAMERA (WALL MOUNTED)
C CCTV CAMERA (CEILING MOUNTED)
PUSH BUTTON CONTROL
H HEAT DETECTOR (CEILING MOUNTED)
SPD SURGE PROTECTION DEVICE
CABLE TRAY
KITCHEN EQUIPMENT CALLOUT (REFER TO SCHEDULE)#
DUPLEX RECEPTACLE (@ 6" ABOVE COUNTER)
DUPLEX RECEPTACLE (GFI TYPE @ 18"AFF)
DUPLEX RECEPTACLE (USB TYPE @ 18"AFF)
QUAD RECEPTACLE (WALL MOUNTED @ 18"AFF)
QUAD RECEPTACLE (GFI TYPE @ 18"AFF)
QUAD RECEPTACLE (USB TYPE @ 18"AFF)
QUAD RECEPTACLE (@ 6" ABOVE COUNTER)
J JUNCTION BOX (CEILING)
PHONE OR DATA OUTLET (MTD ABOVE COUNTER)
PHONE OR DATA OUTLET (FLOOR MOUNTED)
V FIRE ALARM VISUAL DEVICE (WALL MOUNTED @ 7'-6"
AFF)
A/V FIRE ALARM AUDIBLE/VISUAL DEVICE (WALL MOUNTED @
7'-6" AFF)
FIRE ALARM AUDIBLE DEVICE (CEILING MOUNTED)
FIRE ALARM VISUAL DEVICE (CEILING MOUNTED)
FIRE ALARM AUDIBLE/VISUAL DEVICE (CEILING MOUNTED)
A
V
A/V
S SMOKE DETECTOR (CEILING MOUNTED)
FIRE ALARM PULL STATION (WALL MOUNTED @ 48"
AFF TOP OF BOX)F
T FIRE ALARM TAMPER SWITCH
P FIRE ALARM PRESSURE SWITCH
H HEAT DETECTOR (WALL MOUNTED)
F FIRE ALARM FLOW SWITCH
TV TELEVISION / CATV OUTLET (CEILING MOUNTED)
MULTI-PHASE RECEPTACLE (AS NOTED ON PLAN)
CONDUIT CALLOUT (# INDICATES DIAMETER)#" C.
LIGHTING CONTROL CALLOUT (REFER TO SCHEDULE)#
K SECURITY KEY PAD
PANELBOARD (SURFACE MOUNTED)
PANELBOARD (RECESS MOUNTED)
PIV PRESSURE INDICATING VALVE
#
LIGHT SWITCH, SINGLE POLE
LIGHT SWITCH, 3 WAY TYPE
LIGHT SWITCH, 4 WAY TYPE
LIGHT SWITCH, AUTOMATIC (CONNECT TO LCS)
LIGHT SWITCH, DIGITALLY TIMED (0-30 MINUTES)
LIGHT SWITCH, DIMMER TYPE
LOWER CASE SUBSCRIPT INDICATES SWITCH-LEGa
T
D
A
4
3
OS OCCUPANCY SENSOR (CEILING MOUNTED)
OS OCCUPANCY SENSOR (WALL MOUNTED)
PC PHOTOCELL LIGHTING CONTROL
KEY NOTE CALLOUT (REFER TO KEY NOTES ON SHEET)#
CONTROL PANEL (SURFACE MOUNTED)
CONTROL PANEL (RECESS MOUNTED)
REMOTE TEST STATION FOR DUCT MOUNTED DETECTORS
(WALL MOUNTED)
REMOTE TEST STATION FOR DUCT MOUNTED DETECTORS
(CEILING MOUNTED)
T
T
MMOTOR RATED SNAP SWITCH IN NEMA 1 ENCLOSURE
ELECTRICAL METERING DEVICE
ELECTRICAL UTILITY METER & C/T CABINET
M
M
DUPLEX REC/DATA COMBINATION (FLOOR MOUNTED)
QUADPLEX REC/DATA COMBINATION (FLOOR
MOUNTED)
MULTI-LEVEL SWITCHING CONFIGURATION
DUPLEX RECEPTACLE (GFI TYPE @ 6" ABOVE
COUNTER)
DUPLEX RECEPTACLE (USB TYPE @ 6" ABOVE
COUNTER)
QUAD RECEPTACLE (GFI TYPE @ 6" ABOVE
COUNTER)
QUAD RECEPTACLE (USB TYPE @ 6" ABOVE
COUNTER)
REMOTE FEED-THRU GFCI DEVICE WITH
INDICATOR LIGHT. (NO RECEPTACLE)G
FIRE
12"
DOOR, OPENING
OR END OF
WALL
NOTE:
DEVICES SHOWN WITHIN 48" OF EACH OTHER ON ALL ELECTRICAL PLANS SHALL BE ALIGNED
PER THIS DETAIL. IF DEVICES ARE SHOWN IN MIDDLE OF WALL, THEN CENTER DEVICES ON
WALL.
18"
48"
SEE LEGEND
TELEVISION
DEVICE
RECEPTACLE
VOICE/DATA OUTLET
LIGHT
SWITCH
HVAC THERMOSTAT,
HUMIDISAT, CO
SENSOR, ETC.
FIRE ALARM ANNUNCIATION DEVICE
6"
CL
PHONE OUTLET
CARD
READER
6"
6"
6"
APPROXIMATE LOCATION
OF SWITCHBOARD "MDP-A"
EXISTING TELEPHONE/DATA
EQUIPMENT ROOM
SEE DETAIL 1/E0.2 FOR SIZING
PANEL "LP"
EXISTING PANEL "HB"
EXISTING PANEL "LB"
EXISTING PANEL "EB"
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
US21815US21815US21815
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
PR
OJE
CT
NO
.
DA
TE
DRAWING NO.
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
T
HE
RE
ON
AR
E T
HE
PR
OP
ER
TY
OF
B
ELK
A E
NG
INE
ER
ING
AS
SO
CIA
TE
S,
INC
. T
HE
RE
PR
OD
UC
TIO
N,
CO
PY
ING
, O
R U
SE
OF
TH
IS
DR
AW
ING
WIT
HO
UT
TH
E W
RIT
TE
N
CO
NS
EN
T O
F B
ELK
A E
NG
INE
ER
ING
A
SS
OC
IAT
ES
, IN
C.
IS P
RO
HIB
ITE
D
AN
D A
NY
IN
FR
ING
EM
EN
T W
ILL B
E
SU
BJE
CT
TO
LE
GA
L A
CT
ION
.
PR
OJE
CT
TIT
LE
A/E
SE
AL
A/E
SE
AL
DR
AW
ING
TIT
LE
01-22-19
2/8
/2019 1
1:1
7:5
1 A
M
E0.1
U5
01.1
8
01.1
4.1
9
EL
EC
TR
ICA
L N
OT
ES
& L
EG
EN
DS
JJS
CE
S
CO
LIS
EU
M L
AU
ND
RY
EQ
UIP
ME
NT
RE
LO
CA
TIO
N
Caro
lina
Co
lise
um
70
1 A
sse
mb
ly S
t.C
olu
mbia
, S
C 2
920
8
GENERAL EXISTING CONDITION NOTES1 AREAS OF WORK EXIST FOR THIS PROJECT WHICH ARE NOT ACCESSIBLE OR HAVE LIMITED ACCESS DURING
DESIGN. AS SUCH CONTRACTOR SHALL VERIFY ALL UTILITIES IN AREA OF WORK BEFORE DEMOLITION OF ANY
SERVICE. ANY ELECTRICAL COMPONENTS NOT SHOWN SHALL BE IDENTIFIED AND THE ARCHITECT AND
ENGINEER SHALL BE NOTIFIED AS SOON AS POSSIBLE. NO ELECTRICAL REWORK SHALL BE COMMENCEDWITHOUT COORDINATION OF BOTH ARCHITECT AND ENGINEER.
2 IN AREAS WHERE THE EXISTING CEILINGS ARE NOT SLATED TO BE REMOVED, THE CONTRACTOR SHALL WORKTHRU THE EXISTING CEILINGS (SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR AREA OF WORK). THE
CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED TILE OR GRID THAT IS A RESULT OF
THEIR WORK.
3 REFER TO ARCHITECTURAL PLANS FOR PHASING OF CONSTRUCTION.
4 WHERE INSTALLATION REQUIRES CUTTING OR DRILLING OF THE EXISTING FLOOR SLAB, THE CONTRACTORSHALL X-RAY THE EXISTING SLAB PRIOR TO WORK TO ENSURE THAT NO EXISTING UTILITIES OR STRUCTURAL
ELEMENTS IN THE SLAB WILL BE COMPROMISED BY THE WORK. NOTIFY THE ARCHITECT/ENGINEER OF ANY
CONFLICTS THAT WILL REQUIRE RELOCATING THE PROPOSED SLAB WORK. THE CONTRACTOR SHALL BERESPONSIBLE FOR THE REPAIR OF ANY DAMAGED UTILITIES OR STRUCTURAL ELEMENTS CAUSED BY THE SLAB
DEMOLITION.
5 SUPPORT ALL EXISTING CONDUITS AND JUNCTION BOXES ABOVE THE CEILING PER NEC IN THECONSTRUCTION AREA.
6 REMOVE ALL ABANDONED CONDUIT, WIRE, AND COMMUNICATION CABLES ABOVE THE CEILING IN THECONSTRUCTION AREA.
7 PROVIDE JUNCTION BOX COVER PLATES ON ALL EXISTING JUNCTION BOXES ABOVE THE CEILING IN THECONSTRUCTION AREA.
8 SUPPORT ALL EXISTING COMMUNICATION CABLES ABOVE THE CEILING IN THE CONSTRUCTION AREA
9 WHERE INFORMATION SHOWN ON THESE DRAWINGS CONFLICTS WITH VERIFIED FIELD CONDITIONS, IT SHALL BEBROUGHT TO THE ATTENTION OF THE ENGINEER
GENERAL "ELECTRICAL" NOTES1 BRANCH CIRCUIT WIRING SHALL BE NO. 12 AWG UNLESS NOTED OTHERWISE. WHERE CONDUCTOR AND
RACEWAY SIZE ARE SHOWN AT HOMERUN, SUCH SIZE SHALL BE USED FOR THE ENTIRE CIRCUIT.
EXCEPTION: FINAL CONNECTION TO DEVICES, IN OUTLET BOXES, IS NOT REQUIRED TO BE LARGER THAN NO.
12 AWG.
2 20A/120V BRANCH CIRCUITS EXCEEDING 100' IN LENGTH FROM PANEL TO FARTHEST DEVICE OR FIXTURESHALL USE NO. 10 CONDUCTORS AND 3/4"C.
3 PRIOR TO ROUGH-IN, COORDINATE THE LOCATION AND MOUNTING HEIGHT OF ALL WALL AND CEILINGMOUNTED DEVICES WITH THE ARCHITECTURAL ELEVATIONS, MILLWORK SHOP DRAWINGS, AND EXISTING
CONDITIONS. IN THE EVENT OF A CONFLICT, NOTIFY THE ARCHITECT. MINOR ADJUSTMENTS IN DEVICE
LOCATION, I.E. 5'-0" IN ANY DIRECTION SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER.
4 RACEWAYS SHALL BE INSTALLED CONCEALED IN NEW WALL CONSTRUCTION ABOVE CEILINGS, BELOW FLOOR,AND IN OTHER CAVITIES TO THE GREATEST EXTENT POSSIBLE. WHERE EXPOSED RACEWAYS MUST BE USED,
LAYOUT RACEWAYS TO MINIMIZE THE NUMBER OF VERTICAL RUNS.
5 THE ARRANGEMENT, GROUPING, AND ROUTING OF BRANCH CIRCUITS SHALL BE PROVIDED AT THECONTRACTOR'S DISCRETION IN ACCORDANCE WITH GENERALLY ACCEPTED PRACTICE FOR ELECTRICAL WORK,
THE NATIONAL ELECTRICAL CODE REQUIREMENTS, LOCAL ORDINANCES, AND THE FOLLOWING:
5.1 A COMMON NEUTRAL SHALL NOT BE INSTALLED IN A HOMERUN FOR 2 OR 3 BRANCH CIRCUITS UNLESSDIRECTION IS PROVIDED BY THE ENGINEER IN WRITTING FOR A SPECIFIC APPLICATION.
5.2 MULTIPLE SINGLE-POLE BRANCH CIRCUITS (UP TO 3 HOTS, 3 NEUTRALS, 1 GROUND) RATED FOR 30-AMPSOR LESS MAY BE PULLED INTO A SINGLE RACEWAY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SIZING
THE RACEWAYS AND DERATING CONDUCTORS PER NEC ARTICLE 310.15.
5.3 BRANCH CIRCUIT, FEEDER & COMMUNICATION CIRCUITS SHALL BE ROUTED OVERHEAD UNLESS PRIORAPPROVAL HAS BEEN GRANTED BY THE ARCHITECT AND ENGINEER.
5.4 A GROUND CONDUCTOR SHALL BE PROVIDED IN ALL RACEWAYS UNLESS NOTED OTHERWISE.
6 PROVIDE EXPANSION JOINT COUPLINGS ANYWHERE A CONDUIT PASSES THROUGH A BUILDING EXPANSIONJOINT.
7 THE USE OF MC CABLE IS NOT ALLOWED.
8 SEAL ALL EXISTING AND NEW FIRE RATED WALL AND FLOOR PENETRATIONS IN THE CONSTRUCTION AREA
9 SEE THE ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS OF FIRE RATED WALLS.
10 WHEREVER ON THE ELECTRICAL DRAWINGS THE WORD "PROVIDE" IS USED, IT SHALL BE INFERRED TO MEAN"FURNISH AND INSTALL".
11 WHERE CARD READERS AND / OR DOOR CONTACTS ARE SHOWN ON DRAWINGS, COORDINATE WITH ACCESSCONTROL AND DOOR HARDWARE SUPPLIER TO ENSURE THAT ALL RACEWAYS AND BOXES FOR POWER,
SIGNALING, AND DATA ARE PROVIDED TO CARD READER LOCATIONS, DOOR FRAME, POWER SUPPLIES, AND
CABLE-TRAY.
GENERAL "POWER" NOTES1 ALL BRANCH CIRCUITS INDICATED ON THESE PLANS TO BE LARGER THAN NO. 12 AWG SHALL BE SIZED AS
INDICATED FOR THE ENTIRE LENGTH OF THE CIRCUIT.
2 PROVIDE AND INSTALL AN ENGRAVED LAMINATED PLASTIC NAMEPLATE ON EACH ITEM OF ELECTRICALEQUIPMENT SERVING MECHANICAL EQUIPMENT WHICH MATCH MECHANICAL DESCIPTIONS, TO INDICATE THE
DESIGNATION OF THE UNIT ON THE PLANS & THE BRANCH CIRCUIT SERVING THE EQUIPMENT.
3 PROVIDE NEMA CONFIGURATION RECEPTACLES TO MATCH PLUGS ON EQUIPMENT FURNISHED.
4 WHERE SPEED CONTROLLER IS INDICATED TO BE PROVIDED WITH FANS, IT SHALL BE PROVIDED BYMECHANICAL CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR.
5 PROVIDE LABEL ON INSIDE FACE OF COVER PLATE OF ALL RECEPTACLES, SWITCHES & WALL MOUNTEDDEVICES INDICATING PANEL AND BRANCH CIRCUIT TO WHICH EACH DEVICE IS CONNECTED.
GENERAL "LIGHTING" NOTES1 SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR THE EXACT LOCATION OF ALL CEILING MOUNTED LIGHTING
FIXTURES.
2 EXACT LOCATIONS OF LIGHTING FIXTURES IN MECHANICAL SPACES SHALL BE DETERMINED IN THE FIELD. DONOT SUPPORT FIXTURES FROM DUCT OR PIPING. PROVIDE CHAIN OR TRAPEZE-TYPE HANGERS WHERE
FIXTURES CAN NOT BE MOUNTED DIRECTLY TO CEILING.
3 LIGHTING FIXTURE CATALOG NUMBERS ARE INDICATIVE OF THE STYLE OF FIXTURE REQUIRED. CONTRACTORSHALL PROVIDE FIXTURES WITH THE PROPER TRIM, VOLTAGE AND OPTIONS NECESSARY FOR INSTALLATION.
4 DOUBLE-FACED EXIT FIXTURES SHALL BE OF THE SAME MANUFACTURER & SERIES AS THE SINGLE TYPESPECIFIED.
5 REGARDLESS OF CATALOG NUMBER INDICATED IN SCHEDULE, PROVIDE BATTERY PACKS FOR ALL FIXTURESINDICATED ON THE DRAWINGS TO BE EMERGENCY TYPE.
6 ALL EXIT SIGNS SHALL BE CONNECTED TO LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHING.
7 REGARDLESS OF CATALOG NUMBER INDICATED IN SCHEDULE, ALL EXIT SIGNS SHALL BE PROVIDED WITH ABATTERY PACK, SHALL BE WIRED AHEAD OF LOCAL SWITCH AND SHALL NOT BE SWITCHED.
8 REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING DETAILS OF LIGHT FIXTURE TO ACOUSTICAL CEILINGSYSTEM AND STRUCTURE.
GENERAL "DEMOLITION" NOTES1 ALL ELECTRICAL EQUIPMENT TO BE REMOVED SHALL REMAIN THE PROPERTY OF THE OWNER. THE
CONTRACTOR SHALL NOT DISPOSE OF ANY MATERIALS UNTIL RELEASED BY OWNER'S PROJECT MANAGER.
MATERIALS THAT OWNER'S PROJECT MANAGER CHOOSES TO RETAIN SHALL BE DELIVERED BY THE
CONTRACTOR TO A LOCATION DESIGNATED BY THE PROJECT MANAGER. ALL OTHER MATERIALS SHALL BEPROPERLY DISPOSED OF BY THE CONTRACTOR.
2 REMOVE ALL EXPOSED ABANDONED COMMUNICATION CABLE FOUND DURING THE CONSTRUCTION PROCESS.SUPPORT ALL EXISTING REMAINING CABLE PER THE NEC.
3 ELECTRICAL DEVICES NOT SHOWN ON WALLS TO BE DEMOLISHED SHALL BE DEMOLISHED AT NO ADDITIONALCOST TO OWNER.
4 ELECTRICAL DEVICES NOT SHOWN ON CEILINGS OR WALLS TO REMAIN SHALL REMAIN IN PLACE. PROTECTFROM DAMAGE DURING CONSTRUCTION
5 ELECTRICAL DEVICES NOT SHOWN ON CEILINGS TO BE REMOVED SHALL BE TEMPORARILY DISCONNECTED ANDREMOVED DURING DEMOLITION AND RE-INSTALLED ON NEW CEILING IN SAME LOCATION.
ABBREVIATIONS
ABR DESCRIPTION(E) EXISTING
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
BAS BUILDING AUTOMATION SYSTEM
BFC BELOW FINISHED CEILING
BFG BELOW FINISHED GRADE
BOD BOTTOM OF DEVICE
CBB COMMUNICATIONS BACK BOARD
cd CANDELA
CLG CEILING
ECB ENCLOSED CIRCUIT BREAKER
EF EXHAUST FAN
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FDS FUSED DISCONNECT SWITCH
FSD FIRE/SMOKE DAMPER
GBB GROUND BUSS BAR
GFCI GROUND-FAULT CIRCUIT-INTERRUPTING
GFI GROUND-FAULT INTERRUPTING
GP GENERAL PURPOSE
HP HEAT PUMP
ICP IRRIGATION CONTROL PANEL
IG ISOLATED GROUND
J-BOX JUNCTION BOX
LCS LIGHTING CONTROL SYSTEM
NEC NATIONAL ELECTRIC CODE
NFDS NON-FUSED DISCONNECT SWITCH
OC ON CENTER
RFAP REMOTE FIRE ALARM ANNUNCIATOR PANEL
RTU ROOF TOP UNIT
SD SMOKE DETECTOR
SPD SURGE PROTECTION DEVICE
TGB TELEPHONE GROUNDING BUSS BAR
UNO UNLESS OTHERWISE NOTED
UTP UNSHIELDED TWISTED PAIR
VFD VARIABLE FREQUENCY DRIVE
W/ WITH
WH WATER HEATER
WP WEATHERPROOF
XFMR TRANSFORMER
ELECTRICAL DRAWING INDEX
# SHEET NAMEE0.1 ELECTRICAL NOTES & LEGENDS
E0.2 ELECTRICAL ONE-LINE DIAGRAM & PANELBOARD SCHEDULE
E1.1 LIGHTING PLANS
E2.1 POWER/SYSTEMS PLANS
E3.1 MECHANICAL ELECTRICAL PLANS
DEMOLITION/RENOVATION NOTATIONIF NO ANNOTATION IS SHOWN ASSUME EXISTING TO REMAIN INPLACE FOR SOLID LINES AND DEMOLISH FOR DASHED LINES.
DEVICES AND EQUIPMENT NOT SHOWN SHALL BE ASSUMED TOBE EXISTING TO REMAIN IN PLACE.
E EXISTING FIXTURE OR DEVICE TO REMAIN IN PLACE. REPLACEANY BROKEN DEVICES OR PLATES; COLOR TO MATCH EXISTING.
R EXISTING FIXTURE OR DEVICE TO BE REMOVED BY THEELECTRICAL CONTRACTOR. MAINTAIN CONTINUITY OF REMAINING
PORTIONS OF BRANCH CIRCUIT.
RE EXISTING DEVICE TO BE REMOVED BY THE ELECTRICALCONTRACTOR. EXISTING CIRCUIT SHALL BE RETAINED. PROVIDE
NEW DEVICE AS SHOWN ON RENOVATION PLANS.
RN RELOCATED FIXTURE (NEW LOCATION).
RR EXISTING FIXTURE TO BE RELOCATED BY THE ELECTRICALCONTRACTOR TO NEW LOCATION SHOWN ON RENOVATION PLAN.
SCALE: 12" = 1'-0"E0.1
1 DEVICE ALIGNMENT DETAILSCALE: 1/16" = 1'-0"E0.1
2 ELECTRICAL OVERALL PLAN
EQUIPMENT CONNECTION SCHEDULE NOTES1 ALL SWITCHES SHALL BE GENERAL DUTY TYPE, FUSIBLE UNLESS NOTED WITH "NF" (NON-FUSIBLE).
2 "M" DENOTES DISCONNECT SWITCH INTEGRAL WITH MECHANICAL EQUIPMENT.
3 PROVIDE FUSING PER EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
4 EXISTING WASHER 1 SHALL BE CORD CONNECTED TO 20 AMP, 120V DUPLEX RECEPTACLE. 480V SWITCH SHALL BE FUTURE REPLACEMENT WASHER.
EQUIPMENT CONNECTION SCHEDULE
UNIT I.D. CONNECTION DESCRIPTION
ELECTRICAL SUMMARY DISCONNECT SUMMARY
NOTESVOLTAGE
# OFPOLES
LOAD(VA)
FURN.BY
DISC.RATING
TRIP /FUSE
NEMARATING
AHU RELOCATED UNIT 480 V 3 4489 EC 30 A 15 A 1 1
DBF-1 DRYER BOOSTER FAN 208 V 2 2496 30 A M 1 2
DRYER 1 RELOCATED EQUIPMENT (UNI-MAC) 480 V 3 31500 EC 60 A - 4 3
DRYER 2 RELOCATED EQUIPMENT (UNI-MAC) 480 V 3 31500 EC 60 A - 4 3
DRYER 3 RELOCATED EQUIPMENT (ADC) 480 V 3 38400 EC 60 A - 4 3
DRYER 4 RELOCATED EQUIPMENT (ADC) 480 V 3 38400 EC 60 A - 4 3
DRYER 5 CKT 1 RELOCATED EQUIPMENT (CISSELL) 480 V 3 29098 EC 100 A - 4 3
DRYER 5 CKT 2 RELOCATED EQUIPMENT (CISSELL) 208 V 2 450 EC 30 A - 4 3
EDH-1 ELECTRIC DUCT HEATER 480 V 3 33000 60 A M 1 2
EDH-2 ELECTRIC DUCT HEATER 480 V 3 19000 30 A M 1 2
WASHER 1 RELOCATED EQUIPMENT (UNLABELED) 480 V 3 0 EC 30 A - 4 3,4
WASHER 2 RELOCATED EQUIPMENT (UNI-MAT 35) 480 V 3 4200 EC 30 A - 4 3
LIGHT FIXTURE SCHEDULE NOTES1 LUMENS LISTED IN SCHEDULE REPRESENT DELIVERED LUMENS OF FIXTURES.
2 SEE ARCHITECTURAL RCP AND ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHTS.
3 CONFIRM QUANTITIES OF FIXTURES SHOWN IN RCP MATCH QUANTITIES SHOWN ON ELECTRICAL PLANS PRIOR TO BID. IF NO DISCREPANCIES ARE NOTED PRIOR TO BID THE HIGHESTQUANTITY OF EACH FIXTURE TYPE SHOWN SHALL BE PROVIDED.
LIGHT FIXTURE SCHEDULE
SYMBOL
FIXTURE SPECIFICATIONS LAMPING ELECTRICAL
MOUNTING REMARKS NOTESTYPE FIXTURE DESCRIPTION MANUFACTURER CAT. # NO. LAMP TYPEFIXT.LOAD VOLTS
AE 4' LINEAR LED VAPORTIGHTFIXTURE WITH BATTERY PACK
HUBBELL LXEM4-40ML-RFA-EU-ELL14
- LED, 4343L,4000K
39 120 V SURFACE 1,2,3
B 4' LINEAR LED VAPORTIGHTFIXTURE PENDANT MOUNTED
HUBBELL LXEM4-40ML-RFA-EU - LED, 4343L,4000K
39 120 V PENDANT AT 9'0"AFF 1,2,3
BE SAME AS TYPE "B" BUT WITHBATTERY
HUBBELL LXEM4-40ML-RFA-EU-ELL14
- LED, 4343L,4000K
39 120 V PENDANT AT 9'0"AFF 1,2,3
E SEE DEMOLITION/RENOVATIONNOTATION ON SHEET E0.1
X EXIT SIGN WITH BATTERY ANDRED LETTERING
COMPASS CER - LED 4 120 V AS SHOWN ON PLAN 1,2,3
RE
VIS
ION
S
NO
.N
AM
ED
AT
E
EXISTING
SWITCHBOARD
"SWBD"PANEL
"LP"
MAIN ELECTRICAL ROOM
FIRST FLOOR
2E0.2
LAUNDRY H120F
PROVIDE 400A,
3POLE BREAKER
PROVIDE 4-#600KCMIL,
1#2G. IN 4"C.
EXISTING
TYPICAL
SECONDARY
PANELSERVICE ENTRANCE
RATED EQUIPMENT
NEUTRAL GROUND
PROVIDE BUILDING GROUND ROD
CLUSTER. PROVIDE A #4/0
MINIMUM BARE COPPER WIRE
WELDED TO RODS.
20' MINIMUM INTERIOR METAL COLD-WATER PIPE(S)
SERVICE NEUTRAL FROM
UTILITY TRANSFORMER.
SIZE TO MATCH PHASE
CONDUCTORS.
EGC
NEUTRAL GROUND
GEC
METAL OUTLET BOX
GREEN HEX HEAD
GROUNDING SCREW
[250.126]
BOND BOX USING GROUNDING
SCREW, DO NOT USE SHEET
METAL SCREW [250.8]
[250.146]
EGC
SIZE NEUTRALS TO
MATCH PHASE.
GEC [250.66(B)]
PIGTAIL AND
SPLICE.
CONCRETE ENCASED
REINFORCING STEEL OR COPPER
CONDUCTOR.
[250.52(A)(3)] - WHERE
EXISTING
GEC
PIPE GROUNDING CLAMPS. CONNECTION
MADE AT NOT GREATER THAN 5'-0"
FROM POINT OF ENTRANCE [250.52(A)
(1)].
GAS PIPING
EGC PIPE GROUNDING CLAMPS. BOND ONLY
IF LIKELY TO BECOME ENERGIZED BY
FAULTED CONDUCTOR [250.104(B)].
EGCSIZE
NEUTRALS TO
MATCH
PHASE.
GEC
MBJ
GROUNDING LEGEND
ABBR. DESCRIPTION SIZE
MBJ MAIN BONDING JUMPER
SBJ SYSTEM BONDING JUMPER *
GEC GROUNDING ELECTRODE CONDUCTOR 3/0
EGC EQUIPMENT GROUNDING CONDUCTOR **
GROUNDING NOTES:
1. NUMBERS IN BRACKETS REFER TO SPECIFIC SECTIONS OF THE NATIONAL ELECTRICAL CODE.
2. ALL UNDERGROUND OR OTHERWISE INACCESSIBLE GROUND CONNECTIONS AND SPLICES SHALL BE
EXOTHERMICALLY WELDED [250.68].
3. GROUND ELECTRODE FOR SEPARATELY DERIVED SYSTEMS SHALL BE THE NEAREST METAL WATER PIPE OR STRUCTURAL METAL. IF EITHER IS NOT AVAILABLE, PROVIDE GROUNDING CONDUCTOR BACK TO MAIN
GROUND BUS AT SERVICE ENTRANCE.
4. PROVIDE A GROUND WIRE IN ALL CONDUITS.
5. EARTH SHALL NOT BE USED AS THE SOLE GROUND RETURN PATH FOR ANY EQUIPMENT POWERED UNDER
THIS PROJECT.
6. NO ALUMINUM SHALL BE USED FOR GROUNDING WORK WITHOUT THE SPECIFIC WRITTEN PERMISSION OF THE
ENGINEER. EXCEPTION: ALUMINUM BUILDING STRUCTURAL MATERIALS SHALL BE BONDED WITH LISTED
ALUMINUM EQUIPMENT WITH ALUMINUM TO COPPER CONNECTORS FOR ROUTING COPPER EGC'S.
7. PROVIDE GROUNDING BUSHING ON BOTH ENDS OF ALL SERVICE ENTRANCE RACEWAYS, SIZE AS A GEC
[250.80]. THIS INCLUDES RIGID STEEL ELBOWS ON PVC CONDUIT.8. ALL METAL ENCLOSURES AND RACEWAYS SHALL BE BONDED TO GROUND [250.86]. FOR CIRCUITS OVER
250V PROVIDE BOND PER [250.97], STANDARD LOCKNUTS ARE NOT ACCEPTABLE.
9. PROVIDE EGC CONNECTED TO ANY JUNCTION BOX WHERE SPLICE IS MADE [250.148] OR WHERE A DEVICE
IS INSTALLED.
10. PROVIDE BOND TO EXPOSED METAL ON ALL MOTORS, PUMPS, AND LIGHTING FIXTURES PER [250.112].
* SIZE PER TABLE 250.66 OF THE NEC OR
12.5% OF CONDUCTOR SIZE [250.28].
** SIZE PER TABLE 250.122.
DIAGRAM PROVIDES OVERALL VIEW OF BUILDING GROUNDING SYSTEM. EQUIPMENT SHALL BE GROUNDED BASED ON ITS PORTION OF THIS DIAGRAM.
3/0
SSBJ SUPPLY SIDE BONDING JUMPER 2/0
TIE SSJB TO A
GROUNDING BUSHING ON
EACH SERVICE ENTRANCE
CONDUIT.
SSBJ
NOTE 3
GEC
EGC
TYPICAL
SUB-PANEL
NEUTRAL GROUND EGC
EGC
SBJ
TRANSF.
NEUTRAL
LUG
TYPICAL
TRANSFORMER
GROUND
SIZE NEUTRALS TO
MATCH PHASE.
BUILDING STEEL
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
US21815US21815US21815
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
PR
OJE
CT
NO
.
DA
TE
DRAWING NO.
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
T
HE
RE
ON
AR
E T
HE
PR
OP
ER
TY
OF
B
ELK
A E
NG
INE
ER
ING
AS
SO
CIA
TE
S,
INC
. T
HE
RE
PR
OD
UC
TIO
N,
CO
PY
ING
, O
R U
SE
OF
TH
IS
DR
AW
ING
WIT
HO
UT
TH
E W
RIT
TE
N
CO
NS
EN
T O
F B
ELK
A E
NG
INE
ER
ING
A
SS
OC
IAT
ES
, IN
C.
IS P
RO
HIB
ITE
D
AN
D A
NY
IN
FR
ING
EM
EN
T W
ILL B
E
SU
BJE
CT
TO
LE
GA
L A
CT
ION
.
PR
OJE
CT
TIT
LE
A/E
SE
AL
A/E
SE
AL
DR
AW
ING
TIT
LE
01-22-19
2/8
/2019 1
1:1
7:5
1 A
M
E0.2
U5
01.1
8
01.1
4.1
9
EL
EC
TR
ICA
L O
NE
-LIN
E D
IAG
RA
M &
PA
NE
LB
OA
RD
SC
HE
DU
LE
JJS
CE
S
CO
LIS
EU
M L
AU
ND
RY
EQ
UIP
ME
NT
RE
LO
CA
TIO
N
Caro
lina
Co
lise
um
70
1 A
sse
mb
ly S
t.C
olu
mbia
, S
C 2
920
8
NOT TO SCALEE0.2
1 POWER ONE-LINE DIAGRAM
NOT TO SCALEE0.2
2 GROUNDING DETAIL
ELECTRICAL DISTRIBUTION SYSTEM
PANEL DISTRIBUTION PHASE# OFWIRES
MAINSTYPE MCB
FEDFROM REMARKS
SWBD 480 V/3-0 3 4 5000 A EXISTING, MANUFACTURER: WESTINGHOUSE
LP 480 V/3-0 3 4 MCB 400 A SWBD
NOTES:
TOTAL PER PHASE AMPACITY: 276 276 276 CONNECTED AMPACITY: 276
TOTAL PER PHASE KVA: 76.5 76.5 76.5 CONNECTED KVA: 229.6
41 12.8 0.0 -- -- PREPARED SPACE 42 --
39 12.8 0.0 -- -- PREPARED SPACE 40 --3-#6, 1-#6, 1-#10
37
DRYER #4 (ADC) 60 3
12.8 0.0 -- -- PREPARED SPACE 38 --
35 12.8 0.0 -- -- PREPARED SPACE 36 --
33 12.8 0.0 -- -- PREPARED SPACE 34 --3-#6, 1-#6, 1-#10
31
DRYER #3 (ADC) 60 3
12.8 0.0 -- -- PREPARED SPACE 32 --
29 10.5 0.0 -- -- PREPARED SPACE 30 --
27 10.5 0.0 -- -- PREPARED SPACE 28 --3-#6, 1-#6, 1-#10
25
DRYER #2 (UNI-MAC) 60 3
10.5 0.0 -- -- PREPARED SPACE 26 --
23 10.5 0.0 -- -- PREPARED SPACE 24 --
21 10.5 0.0 -- -- PREPARED SPACE 22 --3-#3, 1-#3, 1-#8
19
DRYER #1 (UNI-MAC) 100 3
10.5 0.0 -- -- PREPARED SPACE 20 --
17 6.3 1.4 18
15 6.3 1.4 163-#10, 1-#10, 1-#10
13
EDH-2 30 3
6.3 1.4
3 30 WASHER #2 (UNI-MAT 35)
14
3-#10, 1-#10, 1-#10
11 11.0 0.0 12
9 11.0 0.0 103-#6, 1-#6, 1-#10
7
EDH-1 50 3
11.0 0.0
3 30 WASHER #1 (FUTURE)
8
3-#10, 1-#10, 1-#10
5 1.5 9.7 6
3 1.5 9.7 43-#10, 1-#10, 1-#10
1
AHU - LAUNDRY 25 3
1.5 9.7
3 100 DRYER #5 (CISSELL, CKT 1: HEAT)
2
3-#3, 1-#3, 1-#8
WIRE SIZE CKT DESCRIPTION BKR P A B C P BKR DESCRIPTION CKT WIRE SIZE
MOUNTING: SURFACE ENCLOSURE: Type 1
SUPPLIED FROM: SWBD WIRES: 4 MCB RATING: 400 A
PHASES: 3 MAINS RATING: 400 A
PANELBOARD:
LPDISTRIBUTION: 480/277 Wye A.I.C. RATING: 28,860
3/4"C.
1"C.
3/4"C.
1"C.
1"C.
1"C.
1"C.
1 1/4"C.
3/4"C.
3/4"C.
RE
VIS
ION
S
NO
.N
AM
ED
AT
E
UP
UPUP
UP
UP
UPUP
UP
RR
E
E
R R
R R
R R R R
RR
R R R
R
R
RR
RR
R
E
E
RR
203TRASH
203A
LAUNDRY
ACCESS
203BLAUNDRY
201D
FOOD
SERVICE
E
E
RN
1
X
X
X X
3
3
B
B
BE
B
BE
B
B
B
AE
E
E
RN
AE
2
E E
SHADING INDICATES EMERGENCY FIXTURE SUPPLIED WITH EMERGENCY BATTERY PACK
CE = UPPERCASE LETTER / LETTERS INDICATE FIXTURE TYPEd = LOWERCASE LETTER INDICATES SWITCH IDENTIFICATION NL or EM = INDICATES NON SWITCHED "NIGHT LIGHT" / "EMERGENCY"A-2 = DESIGNATES PANEL NAME - CIRCUIT NUMBER
NOTE:
ALL "EM" FIXTURES INDICATED IN PLAN CONTAIN EMERGENCY BALLASTS. ALL EMERGENCY BALLAST FIXTURES REQUIRE AN EXTRA CONSTANT POWER CONDUCTOR TO BE CONNECTED TO THE EMERGENCY BALLAST FOR CHARGING. CONDUCTOR MUST NOT BE CONTROLLED BY ANY LIGHTING SYSTEM OR HAVE POWER INTERUPTED AT ANY TIME. "NL" FIXTURES SHALL HAVE ABSOLUTELY NO LIGHTING CONTROL & SHALL BE OPERATIONAL AT ALL TIMES.
IN BOTH CASES "EM" & "NL" , WHERE UTILITY POWER SHOULD FAIL, FIXTURES SHALL REMAIN OPERATIONAL FOR A MINIMUM 90 MINUTES @ 1400 LUMENS.
NL A-2
CE
LIGHT FIXTURE PLAN KEY
d
N
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
US21815US21815US21815
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
PR
OJE
CT
NO
.
DA
TE
DRAWING NO.
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
T
HE
RE
ON
AR
E T
HE
PR
OP
ER
TY
OF
B
ELK
A E
NG
INE
ER
ING
AS
SO
CIA
TE
S,
INC
. T
HE
RE
PR
OD
UC
TIO
N,
CO
PY
ING
, O
R U
SE
OF
TH
IS
DR
AW
ING
WIT
HO
UT
TH
E W
RIT
TE
N
CO
NS
EN
T O
F B
ELK
A E
NG
INE
ER
ING
A
SS
OC
IAT
ES
, IN
C.
IS P
RO
HIB
ITE
D
AN
D A
NY
IN
FR
ING
EM
EN
T W
ILL B
E
SU
BJE
CT
TO
LE
GA
L A
CT
ION
.
PR
OJE
CT
TIT
LE
A/E
SE
AL
A/E
SE
AL
DR
AW
ING
TIT
LE
01-22-19
1/2
2/2
019 3
:59:1
3 P
M
E1.1
U5
01.1
8
01.1
4.1
9
LIG
HT
ING
PL
AN
S
JJS
CE
S
CO
LIS
EU
M L
AU
ND
RY
EQ
UIP
ME
NT
RE
LO
CA
TIO
N
Caro
lina
Co
lise
um
70
1 A
sse
mb
ly S
t.C
olu
mbia
, S
C 2
920
8
KEY NOTES
1 EXISTING EXIT SIGN SHALL BE REMOVED AND REINSTALLED IN THE SAMELOCATION, PENDANT MOUNTED AT APPROXIMATELY 3'0" BELOW CEILING.
2 COORDINATE MOUNTING HEIGHT AND LOCATION OF LIGHTING FIXTURESWITH LAUNDRY AND HVAC EQUIPMENT AND DUCTWORK. LIGHTING SHALL
BE BELOW ALL EQUIPMENT AND DUCTWORK TO PREVENT SHADOWING.
GENERAL NOTES1 ELECTRICAL CONTRACTOR SHALL RE-USE EXISTING LIGHTING CIRCUIT(S)
THAT SERVED AREA FOR RENOVATION PHASE LIGHTING FIXTURES.
SCALE: 1/4" = 1'-0"E1.1
1 LIGHTING DEMOLITION PLAN
SCALE: 1/4" = 1'-0"E1.1
2 LIGHTING RENOVATION PLAN
0 8' - 0" 12' - 0" 16' - 04' - 0"
SCALE: 1/4" = 1'-0"
RE
VIS
ION
S
NO
.N
AM
ED
AT
E
UP
UPUP
UP
J J J
J
J
A/V S
A/V
JJ
UP
UPUP
UP
A/V S
A/V
E
R R R R
R
R
RRRR
COMPACTOR
R
R
MOTION
MOTION
RRRR
SECURITY PAD
HVAC CTRLS
R
SECURITY
ENCLOUSRE
R
R
E E2
RR
1
203TRASH
203A
LAUNDRY
ACCESS
203BLAUNDRY
201D
FOOD
SERVICE
E
PANEL "LP"
COMPACTOR
RN
DRYER
1
DRYER
2
DRYER
3
DRYER
4
DRYER
5 CKT
1
WASHER
1
WASHER
2
RN
RN
60cd
E
E
13
19,21,23 25,27,29 31,33,35 37,39,412,4,6
8,10,12 14,16,18
RN
4
5 5
2
DRYER
5 CKT
2
6
UNI-MAC
UNI-MAC
ADC
ADC
CISSELL
SMALLER
UNLABELED
UNI-MAT
35
N
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
US21815US21815US21815
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
PR
OJE
CT
NO
.
DA
TE
DRAWING NO.
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
T
HE
RE
ON
AR
E T
HE
PR
OP
ER
TY
OF
B
ELK
A E
NG
INE
ER
ING
AS
SO
CIA
TE
S,
INC
. T
HE
RE
PR
OD
UC
TIO
N,
CO
PY
ING
, O
R U
SE
OF
TH
IS
DR
AW
ING
WIT
HO
UT
TH
E W
RIT
TE
N
CO
NS
EN
T O
F B
ELK
A E
NG
INE
ER
ING
A
SS
OC
IAT
ES
, IN
C.
IS P
RO
HIB
ITE
D
AN
D A
NY
IN
FR
ING
EM
EN
T W
ILL B
E
SU
BJE
CT
TO
LE
GA
L A
CT
ION
.
PR
OJE
CT
TIT
LE
A/E
SE
AL
A/E
SE
AL
DR
AW
ING
TIT
LE
01-22-19
2/8
/2019 1
1:1
7:5
2 A
M
E2.1
U5
01.1
8
01.1
4.1
9
PO
WE
R/S
YS
TE
MS
PL
AN
S
JJS
CE
S
CO
LIS
EU
M L
AU
ND
RY
EQ
UIP
ME
NT
RE
LO
CA
TIO
N
Caro
lina
Co
lise
um
70
1 A
sse
mb
ly S
t.C
olu
mbia
, S
C 2
920
8
KEY NOTES
1 EXTEND CIRCUIT FROM DEMOLISHED RECEPTACLE LOCATION TO THISRECEPTACLE.
2 COORDINATE RELOCATION OF EXISTING TRASH COMPACTOR WITH OWNERAND ARCHITECT BEFORE ROUGH-IN. MODIFY AND EXTEND EXISTING
BRANCH CIRCUIT AS REQUIRED.
3 PENDANT MOUNT FIRE ALARM INDICATING DEVICE AT SAME HEIGHT ASLIGHTING. SMOKE DETECTOR SHALL BE MOUNTED ON STRUCTURAL
CEILING HIGH BUT STILL ACCESSIBLE FOR SERVING.
4 ELECTRICAL CONTRACTOR SHALL RELOCATE INDICATING DEVICE SUCH THATIT IS NOT COVERED/CONCEALED BY DUCT WORK.
5 ELECTRICAL CONTRACTOR SHALL SERVE THIS RECEPTACLE WITH ADEDICATED 20 AMP CIRCUIT FROM PANEL "LB". ELECTRICAL
CONTRACTOR SHALL COORDINATE AVAILABLE SPACE AND CIRCUITS WITH
OWNER'S RESIDENT ELECTRICIAN IN EXISTING PANEL "LB". PROVIDEBREAKERS AS NEEDED. SEE ELECTRICAL OVERALL PLAN ON SHEET E0.1
FOR LOCATION OF PANEL.
6 ELECTRICAL CONTRACTOR SHALL SERVE THIS RECEPTACLE WITH ADEDICATED 20 AMP, 208V, SINGLE PHASE CIRCUIT FROM PANEL "LB".
ELECTRICAL CONTRACTOR SHALL COORDINATE AVAILABLE SPACE AND
CIRCUITS WITH OWNER'S RESIDENT ELECTRICIAN IN EXISTING PANEL "LB".PROVIDE BREAKERS AS NEEDED. SEE ELECTRICAL OVERALL PLAN ON
SHEET E0.1 FOR LOCATION OF PANEL.
GENERAL NOTES1 ELECTRICAL DEVICES ON THIS SHEET SHALL BE CIRCUITED FROM PANEL
"LP" WITH CIRCUIT NUMBER SHOWN, UNLESS INDICATED OTHERWISE.
SCALE: 1/4" = 1'-0"E2.1
1 POWER/SYSTEMS DEMOLITION PLAN
SCALE: 1/4" = 1'-0"E2.1
2 POWER/SYSTEMS RENOVATION PLAN
0 8' - 0" 12' - 0" 16' - 04' - 0"
SCALE: 1/4" = 1'-0"
RE
VIS
ION
S
NO
.N
AM
ED
AT
E
UP
UPUP
UP
UP
UPUP
UP
1 1
203TRASH
203A
LAUNDRY
ACCESS
203B
LAUNDRY
201D
FOOD
SERVICE
DBF-1
EDH-1
EDH-2AHU
PANEL "LP"
7,9,11
1,3,513,15,17
2
N
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
(803) 731-0650 p | (803) 960-6443 c
ENGINEERING
7 CLUSTERS COURT, SUITE 201 | COLUMBIA, SC | 29210
ASSOCIATES, INC.
BELKA
CONTACT: CLIFF STRINGFIELD
US21815US21815US21815
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. 26181
R
A
NILORACHTU
O
S
J EE
NI
GN
E
LANOISSEF
OR
PD
ES
NE
CILA
S
ON E
AR
T
L.HERA
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
No. C00953
ASSOC. INC.
BELKA
ENGINEERING
A
NILORACHTU
O
S
CE
RT
I FI CATE OF AUTHOR
I ZA
TI O
N
PR
OJE
CT
NO
.
DA
TE
DRAWING NO.
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
T
HE
RE
ON
AR
E T
HE
PR
OP
ER
TY
OF
B
ELK
A E
NG
INE
ER
ING
AS
SO
CIA
TE
S,
INC
. T
HE
RE
PR
OD
UC
TIO
N,
CO
PY
ING
, O
R U
SE
OF
TH
IS
DR
AW
ING
WIT
HO
UT
TH
E W
RIT
TE
N
CO
NS
EN
T O
F B
ELK
A E
NG
INE
ER
ING
A
SS
OC
IAT
ES
, IN
C.
IS P
RO
HIB
ITE
D
AN
D A
NY
IN
FR
ING
EM
EN
T W
ILL B
E
SU
BJE
CT
TO
LE
GA
L A
CT
ION
.
PR
OJE
CT
TIT
LE
A/E
SE
AL
A/E
SE
AL
DR
AW
ING
TIT
LE
01-22-19
1/2
2/2
019 3
:59:1
5 P
M
E3.1
U5
01.1
8
01.1
4.1
9
ME
CH
AN
ICA
L E
LE
CT
RIC
AL
PL
AN
S
JJS
CE
S
CO
LIS
EU
M L
AU
ND
RY
EQ
UIP
ME
NT
RE
LO
CA
TIO
N
Caro
lina
Co
lise
um
70
1 A
sse
mb
ly S
t.C
olu
mbia
, S
C 2
920
8
KEY NOTES
1 ELECTRICAL CONTRACTOR SHALL DISCONNECT UNIT FOR REMOVAL BYMECHANICAL CONTRACTOR. MAINTAIN CONTINUITY OF REMAINING PORTION
OF CIRCUIT.
2 ELECTRICAL CONTRACTOR SHALL PROVIDE A 25 AMP, 208 VOLT, SINGLEPHASE CIRCUIT BREAKER IN EXISTING PANEL "LB" TO SERVE THIS UNIT
(SEE ELECTRICAL OVERALL PLAN ON SHEET E0.1 FOR LOCATION OF
PANEL). ELECTRICAL CONTRACTOR SHALL COORDINATE AVAILABLE SPACEAND CIRCUITS WITH OWNER'S RESIDENT ELECTRICIAN IN EXISTING PANEL
"LB". ELECTRICAL CONTRACTOR SHALL FEED THIS UNIT WITH 2-#10,
1-#10 GROUND IN 3/4" CONDUIT. ELECTRICAL CONTRACTOR SHALL
TURN OVER ANY BREAKERS REMOVED FROM PANEL "LB" TO MAKE ROOMFOR 25 AMP BREAKER.
SCALE: 1/4" = 1'-0"E3.1
1 MECHANICAL ELECTRICAL DEMOLITION PLAN
SCALE: 1/4" = 1'-0"E3.1
2 MECHANICAL ELECTRICAL RENOVATION PLAN
0 8' - 0" 12' - 0" 16' - 04' - 0"
SCALE: 1/4" = 1'-0"
GENERAL NOTES1 ELECTRICAL DEVICES ON THIS SHEET SHALL BE CIRCUITED FROM PANEL
"LP" WITH CIRCUIT NUMBER SHOWN, UNLESS INDICATED OTHERWISE.
RE
VIS
ION
S
NO
.N
AM
ED
AT
E