UP TO 2100 kW(2815 HP)
+ The 32-bit High Speed Digital Signal Processor protects the drive against the short circuit or ground fault conditions. User setable over load function protects the load against the over load conditions.
+ Soft stall current limit reduces the output frequency if the output current exceeds the set level before the drive trips. Input and Output Phase Loss to prevent loading on the other phases.
Easy to Protect
+ The cooling fan, one of the common service parts can be easily removed for replacement.
+ Total Conductive Time and Total Run Time provides the information about the drive and machine usage for the monitoring of serviceable parts.
Easy to Maintain
+ Auxiliary Drive feature allows the user to control two different motors with different HP and control schemes.
+ Multi-pump control feature allows the control of 5 pumps with single drive which doesn't require PLC.
+ Built-In energy meter displays all electrical parameters, which eliminates the need of separate energy meter.
+ 50ºC (122ºF) design, eliminates the need of derating the drive.
+ Built-in PID, PLC and application specific software reduces the peripherals’ cost.
+ Built-in energy saving calculator and high efficiency operation mode.
+ Modbus-RTU connectivity offered as a standard.
+ No option board required for encoder feedback.
Easy to Economize
+ The AXPERT-EAZY has been downsized considerably hence require less space to mount.
+ Well-defined terminations for power and control circuit allows user to install and wire the drive easily. Use of terminals with captive screws on the main control board facilitates single-handed installation.
Easy to Install & Wire
+ 80-character, 4-line LCD display & 8-key keypad (HMI)
+ Self-explanatory full parameter name is displayed on Digital Operation Panel for easy programming. This allows user to set parameters without referring to the manual.
+ Navigation of parameters made easy with self-explanatory functional keys like NORM, MODE, GROUP, UP & DOWN, RUN & STOP for easy operation in local mode.
+ 8 selectable parameters on single screen helps to monitor critical parameters simultaneously.
+ Fault history with last ten faults and 8 important parameters helps in trouble shooting.
Easy to Operate & Program
+ Advanced control is easy and less expensive with configurable analog / digital I/O and integral PID.
+ Digital Operation Panel can be extended to 300 meter (1000 ft) for remote operation through optional cable.
+ Easily configurable control modes as per the application requirement.
+ User programmable 8-analog & 15 digital I/O’s.
+TMAxpert-Communicator drive support software for PC.
Easy to Control
1
Improved Efficiency, High Reliability & Unmatched Performance Improved Efficiency, High Reliability & Unmatched Performance
ModBus-RTU Connectivity for Networking
Digital Operation Panel
TMAxpert-Communicator
Energy Saving Calculator
Designed for Harsh Environments
F w d ; L c l ; N o r m a l R u n
M o d e - M G r o u p - 2
M 2 1 3 E n e r g y S a v e d
5 8 M W H
LMode-M F T - 1 Group- 4Timed Over Current592 Vdc 795.6 Amp
50.00 Hz 75 CO
p M o d e - M G r o u - 2
M 2 1 6 M o n e y S a v e d x 1 k
F w d ; L c l ; N o r m a l R u n
2 9 0 I N Rk
2
Key Functions
Ÿ V/F and Vector control modes with & without speed sensor
Ÿ 120 / 150 % overload for 90 seconds in cold start
Ÿ Kinetic Energy Buffering operation
Ÿ High Efficiency operation mode
Ÿ Software functions like PID, Multi pump control, Traverse, Ring spinning frame, Crane & Hoist
Ÿ User programmable in-built PLC
Ÿ Fieldbus interfaces (Modbus as standard, Optional Profibus-DP (slave), DeviceNet, ControlNet, Ethernet, CANopen)
Ÿ Immune to power fluctuations
Ÿ Wide input voltage range
Ÿ Designed for 50 C (122 ) º ºF
ambient temperature
Ÿ State of the art coating on electronics board as standard
Fault History with LastTen Faults with 8 DynamicParameter's Values
User Selectable8 parameter Displayon Single Screen
80 character, 4 line LCD display with back light and 8-key Keypad
Eazy Navigation through MODE, NORM, GROUP,UP, DOWN Keys
Swapping between 8 and 4 parameter display screen by NORM key
ESC
Ÿ Forced draft fan
Ÿ Feed water pump
Ÿ Secondary air fan
Ÿ Slurry pump
Ÿ Cooling tower fan
Ÿ Condensate pump
Ÿ Primary air
Ÿ Induced draft fan
Ÿ Power exhaust fan
Ÿ Compressor
Ÿ Coal mill
Ÿ Pipeline transportation pump
Ÿ Submerged pump
Ÿ Feed water pump for offshore oil platform
Ÿ Water injection pump
Ÿ Compressor
Ÿ Feed water pump
Ÿ Pressure blower
Ÿ Brine pump
Ÿ Descaling pump
Ÿ Feeding pump
Ÿ Drainage pump
Ÿ Mud pump
Ÿ Stirring pump
Ÿ Ball mill
Ÿ Slurry pump
Ÿ Kiln transmission
Ÿ Conveyer
Ÿ Clean water pump
Ÿ Ventilation fan
Ÿ Crusher
Ÿ Blast furnace blower
Ÿ Compressor
Ÿ Water-delivery pump
Ÿ Pusher car
Ÿ Kneader
Ÿ Descaling pump
Ÿ Induced draft fan
Ÿ Compressing blower
Ÿ Stacker/reclaimer
Ÿ Forced draft fan
Ÿ Primary dust removal blower
Ÿ Crane
Ÿ Secondary dust removal blower
Ÿ Kiln draft fan
Ÿ Coal mill
Ÿ Kiln drive
Ÿ Dust removal fan
Ÿ Cooling fan
Ÿ Stone crusher
Ÿ Rotary kiln transmission
Ÿ Pressure blower
Ÿ Sewage pump
Ÿ Induced draft fan
Ÿ Cleaning water pump
Ÿ Forced draft fan
Ÿ Lifting pump
Ÿ Pressure pump
Ÿ Reclaimed water pump
Ÿ Gas blower
Ÿ Soft water pump
Ÿ Pressure pump
Ÿ Water-delivery pump
Ÿ Compressor Ÿ Axial flow pump
Ÿ Paper machine Ÿ Paper winding Ÿ Pulper machine Ÿ Process fans & pumps
Ÿ Mill drive
Ÿ Cane carrier
Ÿ Juice pump Ÿ Fiberizer Ÿ Leveler
STANDARD SPECIFICATIONS
Power SourceTolerance
AMT -
500~575 VAC, 3-Phase, 3-Wire, 50/60 Hz
Voltage tolerance: -15 to +10%, Frequency tolerance: +/-5%
Norm
al
Duty
Heavy
Duty
Max Continuous Rated Current (A) Note 1
Max Applicable Motor (kW) Note 2
Overload Current Rating
Max Continuous Rated Current (A) Note 1
Max Applicable Motor (kW) Note 2
Overload Current Rating
Power SourceTolerance
AMT -
600~690 VAC, 3-Phase, 3-Wire, 50/60 Hz
Voltage tolerance: -15 to +10%, Frequency tolerance: +/-5%
Norm
al
Duty
Heavy
Duty
Max Continuous Rated Current (A) Note 1
Max Applicable Motor (kW) Note 2
Overload Current Rating
Max Applicable Motor (kW) Note 2
Overload Current Rating
037 045 055 075 090 110 132 160 200 250 315 355 400 450 500 630 710 800 900 11E 14E 15E 18E
72 87 110 147 175 215 245 320 360 470 530 600 704 800 844 1067 1205 1440 1613 1992 2500 2700 3200
37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 800 900 1120 1400 1550 1800
120% for 60 seconds, 140% for 2.5 seconds every 5 minutes, 120% for 90 sec in cold start
60 72 87 110 147 175 215 245 320 360 470 530 600 704 800 844 1067 1205 1440 1613 1992 2500 2700
30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 800 900 1120 1400 1550
150% for 60 seconds, 175% for 2.5 seconds every 5 minutes, 150% for 90 sec in cold start
Power SourceTolerance
AMT -
380~480 VAC, 3-Phase, 3-Wire, 50/60 Hz
Voltage tolerance: -15 to +10%, Frequency tolerance: +/-5%
Norm
al
Duty
Heavy
Duty
Max Continuous Rated Current (A) Note 1
Max Applicable Motor (kW) Note 2
Overload Current Rating
Max Continuous Rated Current (A) Note 1
Max Applicable Motor (kW) Note 2
Overload Current Rating
- 4
- 5
- 6
V/F, Closed loop V/F, Sensor less Vector Control, Closed loop Vector Control
Control Method Digital Space Vector PWM Control
Control Mode
0.1~600 Hz for V/F Control
Output Frequency Resolution 0.0001 Hz (20-bit)
Frequency Setting Resolution
V/ Hz Characteristics
Torque Boost Manual / Automatic Selective: 0~20%
Acceleration / Deceleration Time 0.1~6,00,000 Seconds / Linear or S-Curve selective
Co
ntr
ol F
un
ctio
ns
2-Preprogrammed patterns, 1-Custom 3-point setting pattern
0.01 Hz Digital, 0.012 Hz / 50 Hz Analog (12-bit)
Frequency Accuracy Digital references : ±0.01% (0~50 ºC) / Analog references: ±0.01% (0~50 ºC)
Skip Frequency Three frequencies can be set, band can be set up to 10.0 Hz
Slip Compensation Slip compensation frequency up to 5.0 Hz
Carrier Frequency Note3 Default: 5 kHz, 2~10 kHz
Power Loss Carry Through Up to 5 seconds for smooth operation of the system during power loss
DC Braking DC Braking start frequency 0.1~50 Hz, Time: 0~25 seconds,Brake current: 15 to 150%
Digital Operation Panel (Keypad)
Preset Speeds: Using digital inputs Preset input-0, 1 & 2
Frequency Setting Input
Potentiometer: 2 k Ohm
Programmable Analog Inputs
Speed Search Function Allows the drive to start with rotating machinery without damage / tripping.Bump less transfer for redundancy application (Optional)
Static Pot: Frequency Increase/Frequency Decrease using digital inputs
Serial RS-485, PLC Analog Output - 1, 2, 3 & 4
Op
era
tio
n S
pe
cific
atio
ns
Preset Speeds: Using digital inputs Preset input-0, 1 & 2
Static Pot: Torque Increase/Torque Decrease using digital inputs
Digital Operation Panel (Keypad)
Potentiometer: 2 k Ohm
Programmable Analog Inputs
Torque Setting Input
Serial RS 485
PLC Analog Output - 1, 2, 3 & 4
Default: 4 kHz, 2~6 kHz
Frequency Range
037 045 055 075 090 110 132 160 200 250 315 355 400 450 500 630 710 900 10E 12E 14E 17E 18E 21E
46 54 72 87 110 135 150 175 215 290 345 387 426 482 537 662 713 941 1058 1327 1396 1680 1720 2050
37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1700 1800 2100
120% for 60 seconds, 140% for 2.5 seconds every 5 minutes, 120% for 90 sec in cold start
37 46 54 72 87 110 135 150 175 215 290 345 387 426 482 537 662 713 941 1058 1327 1396 1680 1860
30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1700 1800
150% for 60 seconds, 175% for 2.5 seconds every 5 minutes, 150% for 90 sec in cold start
Max Continuous Rated Current (A) Note 1
037 045 055 075 090 110 132 160 200 250 315 355 400 450 500 630 710 900 10E 12E 14E 15E 18E
54 73 87 110 135 150 175 215 290 345 390 430 485 540 670 720 950 1060 1335 1400 1680 1720 2050
37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1550 1800
120% for 60 seconds, 140% for 2.5 seconds every 5 minutes; 120% for 90 sec in cold start
46 54 73 87 110 135 150 175 215 290 345 390 430 485 540 670 720 950 1060 1335 1400 1680 1720
30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1550
150% for 60 seconds, 175% for 2.5 seconds every 5 minutes, 150% for 90 sec in cold start
44
STANDARD SPECIFICATIONSO
pera
tio
n S
pecif
icati
on
s
Programmable to 42 different options: Not Used, Jog Select, Ramp Select, Preset i/p-0, Preset i/p-1, Preset i/p-2, Freq Increase, Freq Decrease, Aux Drive, Emergency Stop, Fault Reset, Ext Fault, Reverse, Terminal, Ref Select 0, Ref Select 1, PR Step Skip, PR Step Hold, PR/RSF Reset, PID Bypass, PID Disable, Emergency Stop-NC, Ext Fault-NC, Run, Stop, Drive Enable-NC, Drive Enable-NO, PLC input 1~ 8, STO, Torque mode etc...
FSV: 0~5 Vdc or 0~10 Vdc (or Inverse)
FSI: 0~20 mA or 4~20 mA (or Inverse)
VIN: 0~10 Vdc (or Inverse)
IIN: 0~20 mA or 4~20 mA (or Inverse)
Digital Inputs 8-Programmable Sequence Inputs, Sink / Source changeable
Programmable Analog Inputs
Programmable Analog Outputs
Digital Outputs
Potential Free Contacts 3-Programmablerelays:
1-NO, 1-NC for 2A @ 240 VACProgrammable between 40 different options same as digital outputs
Network connectivity RS-485 for PC Interface with Modbus-RTU protocol as standardOptional Profibus-DP (slave), DeviceNet, ControlNet, Ethernet, CANopen
The input power factor is approximately 0.9 with 3% ACL / The inverter efficiency will be >98%Consult Amtech for models other than mentioned in this catalog.Note1 : Indicates the total effective value including the higher harmonics. Note2 : The maximum applicable motor output is given for a standard induction motor.Note3 : If the default carrier frequency is exceeded, derate the output current by 5% per 1kHz as the reduced rating. The default carrier frequency for 500 V & 600 V series drives is 4 kHz and can be adjustable between 2~6 kHz.
4-Programmable Sequence Outputs, open collector type
Programmable to 40 different options: Not Used, Run, Local, Reverse Run, I-Detection, Freq. Attain, Speed Detect1, Speed Detect2, Acceleration, Deceleration, Aux Drive, Timer O/P, Zero Speed, Fault Alarm, PID Up Limit, PID Lo Limit, Temp Alarm, Ready, Pump-1~4, Doff-End Alarm, Sleep Mode, Fault, PLC O/P 1~7, PID F/B Ulmt, PID F/B Llmt etc...
5
2-Programmable analog voltage outputs VO1 & VO2: 0~10 Vdc
2-Programmable analog current outputs IO1 & IO2: 4~20 mA
Auto Restart Adjustable up to 10 times for ten faults
PID Controller Inbuilt PID can be used as stand alone
Fault History
Smooth Operation Speed Search, Auto Restart and Power Loss Carry through functions,Heat sink over temperature alarm, KEB (Kinetic Energy Buffering)
Installation Location Indoor
Storage Temperature
Altitude (above sea level)
Humidity
Enclosure
-20~70 ºC (-4~158 ºF)
1000 m (3300 ft) without derating, above this derate 3% per 305 m (1000 ft)
0~95% maximum non-condensing
Ambient Temperature 0~50 ºC (32~122 ºF) for 400V series drives and for 500V/600V series HD ratings0~40 ºC (32~104 ºF) for 500V/600V series ND ratings, contact Amtech for more details.
Pro
tecti
ve S
pecif
icati
on
Display and Keypad unit
Dis
pla
y
Vibration As per EN 60068-2-6, Acceleration: 1 g, Frequency: 10 Hz ~ 150 Hz
En
viro
nm
ent
Last ten faults with status and eight operational parameters like Output Frequency,Output Current, Dc Bus Voltage, Heat Sink Temperature, Input Voltage,Total ON Time, kWH and MWH
Protective Function Current limit, Over Current Fault, Timed Over Current Fault, Load side Short Circuit Fault, Under Current Fault, DC Bus Over Voltage Fault, DC Bus Under Voltage Fault, Temperature Fault, Output Phase Loss Fault, Earth (Ground) Fault, External Fault, Charging Fault, Current Sensor Fail Fault, EEPROM Fault, 4~20mA Reference Missing Fault, Auto Tuning Fault, Emergency Stop, Communication Loss, Output Unbalance Current Fault.
‘IP 00 Standard (IP 20 or higher protection optional)
Programmable between 15 different options: Output Frequency, Output Current, Output Power, Output Voltage, DC Bus Volt, PID Output, Heat sink temperature, PLC Analog Output 1 to 4, Unipolar Torque Current, Bipolar Torque Current, Excite Current and Set Frequency
Total 80-Character, 4-Line LCD panel with backlit, 8-Key keypad, 3-Status Indicating LED for Run, Stop and Fault; Simultaneous display of 8 selectable monitor parameters from O/P Frequency, RPM, Current, % Current, Set Frequency, PID Reference, PID Feed Back, I/P Voltage R-Y, I/P Voltage Y-B, O/P Voltage, DC Bus Voltage, kW, kWH, MWH, Heat sink Temp. in ºC and ºF, Set Torque, Torque Current, Excitation Current, ASR O/P Monitor, ACR O/P Monitor
EXTERNAL DIMENSION FOR 400 V SERIES
FOR 500 V & 600 V SERIES
6
Dimensions in mm (inch)
A B C D E F G
470(18.5)
250(9.8)
262(10.3)
196.5(7.7)
438.5(17.2)
61.5(2.4)
81(3.2)
585(23.0)
250(9.8)
300(11.8)
196.5(7.7)
565(22.2)
61.5(2.4)
186(7.3)
H
61.5(2.4)
61.5(2.4)
AMT-011-4, -015-4, -018-4, -022-4
AMT-030-4, -037-4, -045-4, -055-4
AMT-075-4, -090-4
970(38.2)
360(14.2)
305(12.0)
940(37.0)
127(5.0)
238(9.4)
106(4.2)
364(14.3)
700(27.6)
322(12.7)
217(8.5)
680(26.8)
98(3.9)
145(5.7)
98(3.9)
365(14.4)
AMT-110-4, -132-4, -160-4
AMT-200-4, -250-4
AMT-315-4, -355-4
1330(52.4)
506(19.9)
400(15.7)
1300(51.2)
155(6.1)
528(20.8)
11(0.43)
321(12.6)
AMT-400-4 ~ AMT-18E-4, consult Amtech for detail dimensions
AMT-800 and above rating uses Diode Unit (DU) / Inverter Unit (IU) paralleling technology
224(8.8)
15(0.59)
200(7.87)
138(304.2)
1185(46.6)
481(18.9)
400(15.7)
1155(45.5)
167(6.6)
431(17.0)
187(7.4)
321(12.6)
JL Ø K
Weight in
kg (lb)
18(39.7)
31(68.3)
76(167.6)
103(227.0)
45(99.2)
15(0.59)
10(0.39)
10(0.39)
10(0.39)
10(0.39)
11(0.43)
11(0.43)
15(0.59)
200(7.87)
11(0.43)
15(0.59)
-
-
-
-
-
-
-
Dimensions in mm (inch)
A B C D E F G H JL Ø K
Weight in
kg (lb)
1247(49.0)
506(19.9)
400(15.7)
1217(47.9)
154.5(6.0)
460(18.1)
224.5(8.8)
321(12.6)
117.7(259.4)
200(7.87)
11(0.43)
15(0.59)
906(35.7)
368.5(14.5)
313(12.3)
876(34.5)
121(4.8)
375(14.8)
119(4.7)
364.5(14.3)
65(143.3)
15(0.59)
11(0.43)
--
679.5(26.7)
292(11.5)
300(11.8)
236.5(9.3)
659.5(26.0)
84(3.3)
227.5(9.0)
81(3.1)
28.5(62.8)
10(0.39)
10(0.39)
--
595(23.4)
292(11.5)
300(11.8)
236.5(9.3)
574.5(22.6)
84(3.3)
142.5(5.6)
81(3.1)
22(48.5)
10(0.39)
10(0.39)
--
970(38.2)
360(14.2)
255(10.0)
940(37.0)
127(5.0)
236.5(9.3)
105.5(4.2)
364(14.3)
77.4(170.6)
11(0.43)
15(0.59)
-
AMT-011-5, -015-5, -018-5, -022-5, -030-5
AMT-011-6, -015-6, -018-6, -022-6, -030-6, -037-6
AMT-037-5, -045-5, -055-5
AMT-045-6, -055-6, -075-6
AMT-075-5, -090-5, -110-5
AMT-090-6, -110-6, -132-6
AMT-132-5, -160-5
AMT-160-6, -200-6
AMT-200-5, -250-5, -315-5
AMT-250-6, -315-6, -355-6
For AMT-355-5 ~ AMT-18E-5, AMT-400-6 ~ AMT-21E-6, consult Amtech for detail dimensions
AMT-710-5, -900-6 and above rating uses Diode Unit (DU) / Inverter Unit (IU) paralleling
technology
AMT-200-4-P, -250-4-P
AMT-315-4-P, -355-4-P
1185(46.6)
478(18.7)
186(7.3)
940(37.0)
175.5(6.9)
687(27.05)
11(0.43)
351(13.8)
175.5(6.9)
15(0.59)
186(7.3)
99(218.2)
1085(42.7)
468(18.4)
186(7.3)
839(33.0)
181(7.11)
587(23.1)
160.5(6.32)
326(12.8)
89(196.2)
176(6.93)
11(0.43)
15(0.59)
AMT-200-5-P, -250-5-P, -315-5-P
AMT-250-6-P, -315-6-P, -355-6-P
J JL
Ø K HOLE
L
D JL
Ø K HOLE
L
1185(46.6)
478(18.7)
186(7.3)
940(37.0)
175.5(6.9)
687(27.05)
11(0.43)
351(13.8)
175.5(6.9)
15(0.59)
186(7.3)
102(224.8)
For - P model only
7
CONNECTION AND TERMINALS
I02FSV
P15
0VFSI V01 0V
IIN0V VIN VO2 I01 PSI2
PSI3CANL STOP +24V PSI1
PSI6CANH RUN COM
PSI5 COM PSO2 PSO4
PSO1PSI4 +24V PSO3 COM
TX COM PBN PAN COM
RX PB +5VPA
Note-1 : This circuit is valid upto AMT- 055 - 4. Above this, DCL comes before soft charge circuit.
Control terminals(The terminal block are aligned in two rows.) TB1
+24V
COM
PSI1
PSI2
PSI3
PSI4
PSI5
COM
PSI6
STOP
RUN
INPUT
Analog COM
0-10V PID Feedback
4-20mA Analog input
4-20mA Analog Ref
0-10V Analog Ref
Analog COM
FSV
0V
FSI
VIN
0V
IIN
270W
10kW
33kW 270W
940W
10kW
33kW
+15V
ANALOG
Output Current
(0-10V, 1mA)
Analog COM
(4-20mA)
(4-20mA)Motor Voltage
Motor Power
(0-10V, 1mA)Output FrequencyVO1
VO2
0V
IO1
IO2
50W
50W
270W
270W
PROGRAMMABLEANALOG OUTPUT
ProgrammableRelay 2240V AC, 1A
ProgrammableRelay 1240V AC, 1AR1B
R2A
R2C
R2B
R1A
R1C
Fault Relay240V AC, 1A
NC
FB
FC
PB
PBN
PAN
+5VCOM
ConnectionsEncoder
FA
PA
COM
PSO1
PSO2
PSO3
PSO4
COM
Sequence Outputs
RS-485
Programmable
RX
TX
SEQUENCEINPUT
CANH
CANH
Power SupplyMCCB Filter
Noise
E
ACL
L2
L3
E
W
V
L1 U
L+2L+1 L-
DCL
DB UNIT
+24V
SOURCESOURCE
L<50mJP1
COM
SINK
PSI 5.6kW
+24V
JP1
SINK
L<50m
PSI
+24V
5.6kW
SINK LOGIC SOURCE LOGIC
AXPERT-EAZY
Main-circuit block
P15Control block
PROGRAMMABLE
M
Note-1
Soft charge circuit
(164’)
(164’)
INPUT / OUTPUT TERMINAL FUNCTION
SYMBOL NAME USE
COM
RX DATA-
+24V +24V source This source is used for the Programmable Sequence Inputs. The logic for the Programmable Sequence Inputs can be changed to sink or source with the help of JP1 on the control board.
RUN RUN command This is programmable sequence input and can be configured to different 42 functions using C114.
STOP STOP command This is programmable sequence input and can be configured to different 42 functions using C115.
PSI1-6 Programmable These are programmable sequence inputs and can be configured to Sequence different 40 functions using C101 ~ C106. Inputs 1 ~ 6
PSO1-4 Programmable These are programmable sequence outputs different 40 functions using Sequence C107 ~ C110. Outputs 1 ~ 4
P15 +15V source This is a 10V source used when a frequency setter is connected to the FSV inputcircuit. The frequency setter to be used should be a variable resistor of 2k and 2W.
0V Common This is a common terminal for analog input signals.
FSV Frequency This is mainly used for setting the frequency (speed) input. A maximum frequency Setting Voltage setting is available at 10V input. This setting is valid when FSV 0-10V, FSV 0-5V, FSV input 10-0V or FSV 5-0V is selected as frequency reference input in A106 or D204 or torque
reference input in A108. Also, this input can be configured as PID Reference input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or Variable bias (A706) for math operation.
FSI Frequency This is mainly used for setting the frequency (speed) input. A maximum frequency Setting setting is available at 20mA input. This setting is valid when FSI 0-20mA, FSI 4-20mA, Current input FSI 20-0mA or FSI 20-4mA is selected as frequency reference input in A106 or D204 or
torque reference input in A108. Also, this input can be configured as PID Reference input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or Variable bias (A706) for math operation.
VIN Voltage input This is mainly used for setting the frequency (speed) input. A maximum frequency setting is available at 10V input. This setting is valid when VIN 0-10V is selected as frequency reference input in A106. Also, this input can be configured as PID Reference input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or Variable bias (A706) for math operation.
IIN Current Input This is mainly used for setting the frequency (speed) input. A maximum frequency setting is available at 20mA input. This setting is valid when IIN 4-20mA is selected as frequency reference input in A106. Also, this input can be configured as PID Reference input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or Variable bias (A706) for math operation.
VO1 Vout-1 These are programmable analog voltage outputs 0-10V. In default condition, output frequency signal is assigned to VO1 and output current signal is assigned to VO2.VO2 Vout-2 Different seven internal signals can be assigned to these outputs using C201 & C202. IO1 Iout-1 These are programmable analog current outputs 4-20mA. In default condition, motor
power signal is assigned to IO1 and output voltage signal is assigned to IO2. DifferentIO2 Iout-2 seven internal signals can be assigned to these outputs using C203 & C204. TX DATA+ These two signals are for the two-wire RS-485 serial link. The protocol used is Modbus-RTU.
8
INPUT / OUTPUT TERMINAL FUNCTION
Eazy Drive Software (PC)TMAXPERT-COMMUNICATOR
- Powerful monitoring and control software for PC for controlling maximum drives at a time.
Functions - All parameter reading / writing & monitoring
- Bargraphs- Trend plots- Alarm view
M
Stand-alone option
PowerSupply
Main circuit wiring device
MCCB or Fuse MC I/P Reactor Noice Filter
DCL
DB Unit
Drive unit
O/P Reactor
SYSTEM OPTIONS
Option classification
Line reactor (ACL) / DC choke (DCL)
Noise filter
DBU / DBR unit
Output reactor / Output sine filter
12 / 18-pulse converter for low harmonic requirements
Active Front-end Converter to meet IEEE 519
requirements and regenerative applications
Cabinets / Panels with different IP rating
Types of options
SYMBOL
PA A-Phase Pulses The A-phase positive pulse of encoder is applied at this terminal.
PAN The A-phase negative pulse of encoder is applied at this terminal.
PB B-Phase Pulses The B-phase positive pulse of encoder is applied at this terminal.
PBN The B-phase negative pulse of encoder is applied at this terminal.
+5V +5V source This is +5V source for the encoder. The encoder is required only in case of close loop control mode. Refer chapter-10 for details on encoder specification.
FA Fault Relay These contacts function when a fault occurs (when the FAULT LED is flashing on Contacts Digital Operation Panel). When a fault occurs, the section FA-FC is closed and theFC section FB-FC is open. It can be configured to different 40 functions using C113.
FB
R1A Programmable This is programmable relay and its function is assigned to “Run” condition in default. Relay 1 contacts When a programmed condition occurs, the section R1A-R1C is closed and the sectionR1C R1B-R1C is open. It can be configured to different 40 functions using C111.
R1B
R2A Programmable This is programmable relay and its function is not assigned to any internal signal in Relay 2 contacts default. When any function is assigned using C112 and the programmed condition
occurs, the section R2A-R2C is closed and the section R2B-R2C is open. It can be configured to different 40 functions using C112.
NAME USE
R2C
R2B
9
USER SELECTABLE FUNCTIONS
Multi-pump Control
PID Control Auxiliary Drive Motor Control
Auxillarydrivemotor
Powersupply
Input OFF
ON
Control switching commandAux. Drive
Control switching confirmationAux. Drive
Output Maindrivemotor
IM
IM
Main Drive Control
Auxillary drive control(V/F Control)
Sequence Input Sequence Output
AXPERT-EAZY
Contr
ol
Sele
ction
Aux.Drive
Pattern Run Function & RSF
PLCT & Speed Search Function
KEB (Kinetic Energy Buffering)
TMPC Software AXPERT-COMMUNICATOR Math Operation
10
+ +
+PID PID Output
C609 : PID deviationLower Limit
C603 : PIDReference Input
C602=1
C604 : PIDFeedback Input
C605 : Proportional Gain
C606 : I ntegral Time
C607 Derivative Gain
PID Controller
C610 : PID OffsetAdjustment
C608 : PID deviationUpper Limit
PID M
M
M
M
M
P
P
P
P
P
ConverterPressure Feedback
Pump ON/OFFcomm and
PSO -4
PSO -3
PSO -2
PSO -1
U, V, W
LimiterMonitor
FSI
PID
Feedback
Input ( C604)
AXPERT EAZY AC DRIVE
PID Ref
Input
(C60 3)
Pump-1
Pump-2
Pump-3
Pump-4
Pressure Sensor
Fre
quency
(sp
eed) E201
E202
E203
E204
E205
Time
RUN
Step-1
G301Step-2
G302Step-3
G303Step-4
G304Step-5
G305
F Out
A103M101
Maximum Frequency
C506A201
Set Frequency
MotorSpeed
t
t
tC507
C508
C505M104
I Out
V Out
Speed search current limit
A702: Math Ref Input
A106: Freq Ref Input
Multiplier
Multiplier
Math Operator
A704
Variable Bias
A706
Internal Freq
Command
A703
Fix BiasA705
X/
+
+
A701
C510 Speed Search Match Current Limit
VDC
B319KEB Threshold Level
Under Voltage Level
Output Frequency
Power Failure
Power Returns
KEB ON KEB OFF
5%
OUR OTHER OFFERINGS
We provide complete motion control system solutions or individual system components to address industry specific requirements and optimize your process.
Our solutions are simple, compatible and environment friendly, resulting in efficient production, cost optimization a n d m i n i m i z i n g h u m a n intervention. It even leads to energy conservation especially i n t y p i c a l F a n , B l o w e r applications.
Flagship Solutions
l Axpert-Eazy Series VFD
l Axpert-VT240S Series VFD
l A x p e r t - H i v e r t S e r i e s Medium Voltage Drive
l Axpert-Opti torque Soft Starter
l A x p e r t - E a z y H F - H i g h Frequency Drive
Applications
l Fans, Blowers, Pumps
l Compressors, Centrifuges
l Agitators & Conveyors
l Oil & Gas
l Mining
CA
T .
NO
. :
AE
IL/E
AZ
Y/0
8-1
7
"Automation Made Easy" is our philosophy to simplify the increas ing complex i ty o f modern production systems through our Amtech-Jetter PROCESS PLC technology platform.
Our 30 years experience in Machine, Line, Plant and Networking Automation has helped us to find the best s o l u t i o n i n t e r m s o f functionality, sustainability and efficiency.
Flagship Solutions
J e t C o n t r o l s e r i e s P L C C o n t r o l l e r s , E x p a n s i o n M o d u l e s , J e t v i e w S o f t SCADA, HMIs, Jet Move series Servo and Axes Control System.
Applications
l Paper Machine Automation
l Textiles Manufacturing
l Packaging
l Winder Machine
l Crane & Material Handling Equipment
l CNC Machines
l Semiconductor Assembly Line
l Retrofit solutions
Amtech 's Power Qua l i t y Solutions offer you the synergy of multiple benefits - energy c o n s e r v a t i o n , e n h a n c e d operational efficiency and reliability through a dedicated r a n g e o f p r o d u c t s a n d services.
Products
l Active Harmonic Filter
l Harmonic Reactor
l Static Harmonic Converter
l EMI/RFI Filter
l Sinus Filter
l Active Front end Converter
Services
l Harmonic Audit and Solutions to comply with IEEE-519 standard
l System design, optimization & pay-back analysis
l Consultancy for Power Quality improvement
l Training on Power Quality Management
l Energy Audit and solutions by experienced BEE certified professionals
We offer technology solutions to independent R&D labs as well as industrial segments, l ike Tract ion, Renewable Energy sources (Wind, Solar etc.) thereby zeroing your lead time to commercialization.
Products
l Traction Drive
l High Voltage Power Supply
l Battery back-up drive & systems for critical loads
l Wind Power Converter
l Grid tied Solar Inverter
l Digital Heater controller
Services
l Power Electronics Engineering Services
l Customized solutions for industry specific applications
l Solution for Oil, Gas & Mining
l Power Electronics product development & testing
l Product verification & validation
l Retrofit Solutions
MOTION CONTROL AUTOMATION POWER QUALITY INDUSTRIAL ELECTRONICS
“DRIVE FOR SUCCESS”“AUTOMATION.MADE EASY”
“ONE STOP SOLUTIONTO QUALITY POWER”
“YOUR TECHNOLOGYPARTNER”
i-SineAXPERT-Active Harmonic Filter
i-SineAXPERT-Active Harmonic Filter
N o r m0 . 0 % L 4 1 5 V r y0 . 0 l r 0 0 V oV R a m p . L c l , S t o p
E-6, GIDC Electronics Zone, Gandhinagar - 382028, Gujarat, India.Phone: +91-79-23289101, 23289102, 23289103 | Fax: +91-79-23289111Email: [email protected] | Website: www.amtechelectronics.comSpecifications in this catalog are subject to change without notice.