8
Order code: BOTE32 UP2-RF Dimmer Controller User Manual

UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

Order code: BOTE32

UP2-RF Dimmer Controller

User Manual

Page 2: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablevoltageis230VAC~50Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• WARRANTY:Oneyearfromdateofpurchase.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

Page 3: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 3

Product overview & technical specifications

TheUP2-RFisasinglechannelDMXdimmerwhichcanbeconvertedtoasinglechannelswitchpack.Theunitfeatures0-100%dimminganda3pushbuttonLEDmenusystem.

• Compact,1channelDMX/HTPDimmerPack 

• StandardDMX512Protocol 

• DimPreset-DimLimiterandcanbechangedfromaDimmertoaSwitchPack

• LEDDisplaymakesiteasytosetDMXchannels

• HTPfunction 

• 3-PinXLRinput/output

• Output:2xIECSocket

• Easytousemountingbracket 

• MaximumPower:10A

UP2-RF Dimmer Controller

Specifications

Powersupply 230V,50Hz

Fuse F10A250V

Dimensions 182x92x68mm

Weight 1.1kg

Ordercode BOTE32

01-2xIECoutputs

02-LEDdisplay

03-HTPfader

04-Menubutton

05-Upbutton

06-Downbutton

07-ExternalHTPfader

08-Captivepowerconnection

09-FuseF10A250V

10-3-PinXLRDMXinput

11-3-PinXLRDMXoutput

12-PhonejacktoconnectexternalHTPfader

Inthebox:1 x controller, 1 x External HPT fader & 1 x user manual

IP20

10 11

09

08

12

04 05 06

01

03

02

07

Page 4: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 4

Operating instructions

WhentheunitispowereduptheunitwillshowtheDMXaddressthattheunitwaslastinbeforeitwaspowereddown.IftheDMXaddress123wasselectedintheunitslastusethetheunitwilldisplay“A123”.

Byusingthe“UP” or “DOWN”buttonstheuserisabletoselecttherequiredDMXaddress.OncetheDMXaddressisselected,itwillbeautomaticallystoredintotheunitsmemory.

Pressthe“MENU”buttonuntilthedisplayshowsd---.

Pressthe“UP” or “DOWN” buttonsothedisplayshowsS---.

Pressthe“MENU” buttontoenterswitchpackmode.Usethe“UP” or “DOWN” buttonstochangebetweenS-onandS-oF.

Pressthe“MENU” buttontoexitswitchpackmode.InSwitchpackonmodetheoutputisonandthefixturewillilluminateregardlessoftheDMXsignal.InswitchpackoffmodetheoutputisturnedoffandthefixtureiscontrolledviatheDMXsignal.IftheDMXlevelislessthan40%thefixturewillblackout,above40%thefixturewillilluminate.

DMX address mode:

Switch pack mode:

--- ---

Page 5: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 5

Operating instructions

Dimmer pack mode:

Pressthe“UP” or “DOWN” buttonsothedisplayshowsd---.

---MENU

Pressthe“MENU”buttontoenterDimmerlimitmode.

Usethe“UP” or “DOWN” buttonstochangethevaluebetween10-100.

Usethe“UP” or “DOWN” buttonstochangethevaluebetween00-100.Oncethedimmerpresetisselecteditwillbeautomaticallystoredintotheunitsmemory.

Pressthe“MENU”buttonexitoutofanyoftheaboveoptions.

Pressthe“MENU”buttontoenterDimmerpresetmode.

MENU

MENU

Page 6: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 6

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-512.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Also remember that DMX cable must be daisy chained and cannot be split.

Page 7: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 7

Terminationreducessignaltransmissionproblemsandinterferance.itisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Page 8: UP2-RF Dimmer Controller · 2015. 9. 11. · UP2-RF Dimmer Controller User Manual 4 Operating instructions When the unit is powered up the unit will show the DMX address that the

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 8

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.