16
Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 1

Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Embed Size (px)

Citation preview

Page 1: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 1

Update on Q1 TAS REGION (18 to 22m), layouts.

Page 2: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 2

Motivation.

Reduce and improve interventions in view of LS3. Q1-TAS is a difficult access area, space is very limited and subject to high radiation doses (ALARA considerations).

Page 3: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 3

Page 4: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 4

Page 5: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 5

Baseline lay-out

Assumed BPM integrated into Q1.Bellows between Q1-TAS.Vacuum equipment inside FIN and at IP side (CMS cavern).

ST0666891 etude IP5L_version 1 vide cote IP5ST0667188 Integration vers 1 proposition 1ST0667348 Ligne vide cote Q1 version 1

CATIA models

Page 6: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Situation actuelle

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 6

1447mm 990mm

1480mm

Page 7: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Quick connectors

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 7

Page 8: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Situation actuelle

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 8

430 mm

150 mm

Page 9: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 9

Situation actuelle

Page 10: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 10

Situation actuelle

Page 11: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Baseline scénario

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 11

Page 12: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Baseline scénario

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 12

Page 13: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Baseline scénario

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 13

Page 14: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

Baseline scénario: les 2 vannes coté IP(passage tuyauteries gaz + vide a l’exterieur du FIN)

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 14

Page 15: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 15

TAXS next steps, detail studies

• Vacuum• Alignment (BP support)• Installation• Interventions, remote handling• Risk assessment• Timeline for LS2 needs to freeze lay-out during next year.

Page 16: Update on Q1 TAS REGION (18 to 22m), layouts. D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting1

D. Brethoux, M. Lazzaroni, F. Sanchez Galan, WP8 meeting 16

TAXN at P8 Timeline