2
UPRIGHT TANK AUXILIARY STORAGE TANK WITH FOIL JACKET HT 120 ER HT 160 ERM HT 200 ERM HT 300 ERM HT 400 ERM HT 500 ERM ©Fotolia

UPRIGHT TANK - Austria Email AG€¦ · 1) Installation depth ... Head office and factory: Austria Email AG A-8720 Knittelfeld, Austriastrasse 6 ... in Watt Profile Con- Heat loss

  • Upload
    lykhue

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

UPRIGHT TANK

AUXILIARYSTORAGE TANK WITH FOIL JACKET

HT 120 ERHT 160 ERMHT 200 ERMHT 300 ERMHT 400 ERMHT 500 ERM

©Fo

tolia

n Large heat exchanger surfacesn Welded-in high-performance straight-tube heat exchanger (not susceptible to limescale)n Enamelling and Mg anode comply with DIN 4753n High-quality PU insulation, 50 mmn Upward-facing hot water outlet guarantees complete ventingn Thermometer, dummy flange (D 180 mm, DN 110) and flange insulating cover fitted ex worksn All storage tanks include 1½‘‘ sleeve (sealed ex works) for SH-series

screw-in heaters (except HT 120 ER)n Sensor positioning via dip tube (regulating sleeve)n Operating pressure 10 bar

ACCESSORIES:n Capillary tube charge pump controllern Foil jacket included in delivery, leading to reduced stock inventoryn Height-adjustable feet and plastic rosettes included

1) Installation depth of screw-in heater sleeve for SH heating 2) Installation depth of flange (for built-in heater or finned tube heat exchanger)

ModelHeatingsurface

in m2

Supply temperature

Hot water temperature

Cold water temperature

Flow quantity

HT 160 ERM

HT 300 ERM

HT 400 ERM

HT 500 ERM

HT 200 ERM

Flow performances in kW or l/h

0,57

0,57

0,91

1,40

1,76

1,95

Perfor-mance in-dicator NL

80°C

60°C

10°C

3 m3/h

1,4

2,2

4,0

9,2

14,6

17,7

80°C

45°C

10°C

3 m3/h

16,0

394

19,8

487

31,0

763

42,7

1050

50,7

1247

58,1

1429

70°C

60°C

10°C

2 m3/h

9,5

164

9,7

167

15,5

267

20,9

360

25,5

439

27,2

468

70°C

60°C

10°C

1 m3/h

8,3

144

8,5

146

13,2

227

17,1

294

20,4

351

21,9

377

70°C

60°C

10°C

3 m3/h

10,0

173

10,3

177

16,6

286

22,4

386

27,5

474

29,5

508

80°C

60°C

10°C

1 m3/h

11,8

205

12,5

215

19,1

329

24,8

427

29,3

505

31,7

546

80°C

60°C

10°C

2 m3/h

13,5

235

14,7

253

22,9

394

31,0

534

37,1

639

42,1

725

80°C

60°C

10°C

3 m3/h

14,3

247

15,7

270

24,8

427

33,9

584

41,2

709

48,1

828

70°C

45°C

10°C

1 m3/h

10,5

260

11,9

293

18,0

443

23,0

566

27,2

669

29,8

733

70°C

45°C

10°C

3 m3/h

12,6

312

14,9

367

23,5

578

31,8

782

38,9

957

44,2

1087

70°C

45°C

10°C

2 m3/h

12,0

296

13,9

342

21,7

534

30,1

740

34,8

856

39,2

964

80°C

45°C

10°C

1 m3/h

13,3

329

15,6

384

23,3

573

29,8

733

35,1

863

38,3

942

80°C

45°C

10°C

2 m3/h

15,2

375

18,5

455

28,4

699

39,1

962

45,1

1109

51,2

1260

Model

HT 160 ERM

HT 200 ERM

HT 300 ERM

HT 400 ERM

HT 500 ERM

ETE1)

mm

-

520

520

520

590

670

Anodemm

ø 33 x 300

ø 33 x 300

ø 33 x 430

ø 33 x 600

ø 33 x 700

ø 33 x 700

Diagonalheight

mm1100

1240

1440

1860

1930

1965

Weightkg

70

76

88

115

145

160

ETF1)

mm

400

420

420

420

490

580

263

263

263

263

320

370

543

583

718

898

960

1010

503

503

638

818

880

930

600

610

610

610

680

760

403

668

803

983

1000

1095

Bmm

Cmm

ø Dmm

Emm

Amm

Gmm

Hmm

Imm

Fmm

305

305

305

305

345

470

913

1118

1340

1797

1832

1838

-

668

803

983

1000

1095

633

228

1050

1507

1521

1498

AUXILIARY STORAGE TANK WITH FOIL JACKET

TH- Thermometer ½“ female threadsEH- Screw-in heater sleeve ½“, female threadsZ - Circulation ¾‘‘, male th-

reads (1‘‘ at HT 500 ERM)RM- Regulating sleeve ½“, female threadsVL- Boiler supply 1“ female

threadsRL- Boiler return 1‘‘, female

threadsWW- Hot water outlet 1‘‘, male

threadsKW- Cold water supply 1‘‘,

male threadsBride: Ø 180 mm

© w

ww

.age

ntur

-sch

arf.a

t – 2

42.5

25 –

150

122

– H

T ER

M –

prin

ted

on c

hlor

ine-

free

blea

ched

, env

ironm

enta

lly fr

iend

ly p

aper

. Tec

hnic

al c

hang

es a

nd p

rintin

g er

rors

rese

rved

.

Head office and factory: Austria Email AGA-8720 Knittelfeld, Austriastrasse 6 Phone (03512) 700-0, Fax (03512) 700-239 Internet: www.austria-email.at E-mail: [email protected]

Customer Service: Phone (03512) 700-297E-mail: [email protected]

Sales offices Germany:

Germany North/East D-14770 Brandenburg, Beetzseeufer 3Phone 0049/(0)3381 / 766-0Fax 0049/(0)3381 / 766-244 E-mail: [email protected]

HT 160 ERM

HT 200 ERM

HT 300 ERM

HT 400 ERM

HT 500 ERM

120

160

200

300

400

500

1,24

1,47

1,67

2,19

2,45

2,72

52,0

61,3

69,6

91,3

102,1

113,3

L

L

XL

XXL

XXL

3XL

B

C

C

C

C

C

ECO DESIGN - LABELING

Germany South D-92637 Weiden/Opf., Parksteiner Strasse 49Phone 0049/(0)961 / 63 490-0Fax 0049/(0)961 / 63 490-30E-mail: [email protected]

in kWh/24h Zapf Profile in Watt

Heat loss in EN 12897Con-tent

l

EnergyEfficiency

Class

TECHNICAL DETAILS

Type

HT 120 ER

HT 120 ER

HT 120 ER