60 Three-phase UPS DELPHYS MX from 250 to 900 kVA the Mega Power protection up to 5.4 MVA DELPHYS MX range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances, IDC, Telecom datacentres, semiconductor production lines and big automation manufactures, airports, big air traffic control centres, tunnels. DELPHYS MX, is a true-online “double conversion” UPS system which protects the load from power grid pollution or power failure, from utility power supply and diesel generators. > Data center > Industry > Telecommunications > Processes Your protection for DEFYS 176 A Flywheel COMPLIANT BUREAU VERITAS DELPHYS MX series is attested by Bureau Veritas.

UPS DELPHYS MX - amadeus · PDF filethe Mega Power protection up to 5.4 MVA ... - free cooling compatible to save cooling ... UPS DELPHYS MX from 250 to 900 kVA Fault tolerant architecture

  • Upload
    vothien

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

60

Three-phase UPS DELPHYS MX

from 250 to 900 kVAthe Mega Power protection up to 5.4 MVA

DELPHYS MX range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances, IDC, Telecom

datacentres, semiconductor production lines and big automation manufactures, airports, big air traffic control centres, tunnels.DELPHYS MX, is a true-online “double conversion” UPS system which protects

the load from power grid pollution or power failure, from utility power supply and diesel generators.

> Data center> Industry> Telecommunications> Processes

Your protection for

De

fyS

176

A

FlywheelCOMPLIANT

B U R E A UV E R I T A S

DELPHYS MX series is attested by Bureau Veritas.

61

Three-phase UPS DELPHYS MX

from 250 to 900 kVA

• Parallel system with modular units.• Powerful central bypass for power extension

or redundancy.• Tier 3 and Tier 4 compatible.• Designed for optimal use with STS in

downstream network.

Easy to Service and Maintain

• Specially designed graphic touch screen for easy and ergonomic operation.

• 7 com-slots plug-in communication interfaces for upgrading your operating requirements.

• easy remote monitoring via web browser or via customer’s supervision systems (web, intranet, extranet…).

• Very open connectivity (Modbus / Jbus, Jbus tunnelling, LAN…).

• front accessibility for all components.• Reduced MTTR thanks to extractible power

bridges or fans on “cassette”.

User-friendly operation and remote communication

Flexible architecture

• Internal fault tolerant architecture with internal redundancies and fan failure localisation.

• Intelligent embedded battery monitoring with failed block localisation and preventative remote alarm.

• Able to withstand an output short circuit and overload, ensuring the systems safety under extreme conditions.

• Reliable and robust paralleling mode.• Multisystem automatic cross synchronisation

(ACS) for an optimised use with STS.• Output isolation transformer to reduce

the influence of N-GND (Neutral Line-to-Ground) voltage and load harmonic current on UPS inverter.

• Minimised running costs, by: - Very high efficiency of up to 93.5 %

(lower energy dissipation and cooling costs) equals energy saving in full on line conversion,

- ‘energy saver’ on-line mode allows the number of running units of the system to adapt automatically to the real load,

- free cooling compatible to save cooling costs.

• Valuable space saving with its reduced footprint and exceptional high power density (the most compact unit of its class): 900 kVA in less than 3.2 meters (width) per unit including the by-pass. DELPHYS MX units can also be installed without side or rear access (dependant on requirements).

• Lower infrastructure installation costs benefit from PfC “clean input” rectifier (without filters) with a lasting high input power factor whatever the operation conditions. It means lower input current, in comparison with traditional UPS, therefore no need to oversize upstream transformers or generator sets.

• Intelligent built-in battery monitoring system interacts with “charging mode” to prolong battery lifetime (reduced battery stress thanks to a very low ripple current). The independent charger permanently isolates the batteries from the inverter DC bus in normal mode.

• Designed to match latest IT load requirement.

• Leading power factor load compatible without derating.

High reliability and availability Lower Total Cost of Ownership

AP

PLI

406

A

62

Three-phase UPS DELPHYS MX

from 250 to 900 kVA

Fault tolerant architecture

DELPHYS MX integrates internal redundancy that ensures permanent power supply even during system failure:• redundant ventilation system,• ring bus synchronisation,• no single point of failure since the

synchronisation bus uses a fault tolerant token ring topology that accepts an accidental opening of the synchronisation loop, without UPS malfunctioning or load losses and an alarm is given to the operator at the first fault.

• “Cascade failure” protection function eliminates fault propagation downstream of a module in parallel system when configured with central bypass,

• internal or external “backfeed” protection eliminates any risk of energy feedback upstream of the UPS,

• hardware and software watchdog ensures that the power supplied to applications is secure in case of a circuit and control software fault,

• redundancy of the power supplied to the electronics, locating ventilation faults, preventative detection of faults on a battery component on request.

Protecting your battery investment

EBS (expert Battery System) technology significantly prolongs the battery life:• charge according to an algorithm which

adapts to the environment and the condition of the battery,

• eliminates overloading effects due to permanent floating, which accelerates the corrosion of the positive plates and causes the separators to dry out,

• isolation of the DC battery bus, (independent charger function). Premature ageing, caused by residual ripple from the inverter bridge is eliminated.

Guaranteed battery availability

• the battery and DC circuit are regularly tested automatically and the operator is notified of their condition,

• Available as option, BHC Interactive (Battery Health Check), a battery monitoring system that provides permanent monitoring of the battery system, simplifies maintenance (either preventative or curative) and optimises battery lifetime.

Interacting proactively with the battery charger recharging system (EBS), it optimises battery capacity, increases charger precision, performs automatic battery testing and automatic procedure to recover a block when becoming weaken before it is totally unusable.

DELPHYS MX ensures your power supply is of the utmost quality by using Space Vector Modulation (SVM) digital regulation:• perfectly sinusoidal output voltage THDV <  2 %  with  linear  loads  and  <  3 %  with non-linear loads,

• output voltage precision even when load is completely unbalanced between phases,

• an immediate response to major variations in load, without deviating the output voltage (± 2% in less than 5 ms),

• a very high short circuit capacity up to 4 In (Ph / N) allows selectivity.

Components and power bridges (integrating the latest high performance IGBT) enable the supply:• non-linear loads with high crest factor up

to 3,• loads with a leading power factor up to

0.9 lagging without de-rating of the active power (900 kVA / 800 kW).

The voltage you require: whatever the load

De

fyS

153

A G

B

Without derating

cos ϕ 0,9

0,25

0,50

0,75

1

cos ϕ 1100% kW

kW

-1 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1

cos ϕ 0,9 cos ϕ 0,9cos ϕ 0,9

0,25

0,50

0,75

1

cos ϕ 1100% kW

kVAr

kWLEADINGLEADING LAGGINGLAGGING

Without derating

100% kva

100% kVA

H5 H7 H11 H13 H17 H19

Traditional three-phase rectifier with thyristor

12 pulse rectifier

Low distortion rectifier DELPHYS MX

HARMONICS

THDI %

28 %

1 %

8 %7 %

9 %

5 % 6 %

3,2 % 2,5 %4,7 %

2 %

DELPHYS MX guarantees total compatibility with your low voltage electrical power supply system and, in particular, with generating sets:• sinusoidal current at rectifier THDI input:

4.5 % without filter,• increased power factor upstream of the

rectifier: 0.93 without filter, reducing the current consumed, and therefore the size of cables and protective devices,

• gradual, sequential start-up of the rectifiers in parallel, facilitating take up by the generating set,

• delayed battery recharge when running on generating set to reduce power consumption.

Integration into your electrical network: a “clean” and economical rectifier

UPSDELPHYS Green Power V

I

GR

ee

N 0

66 A

De

fyS

171

A G

B

63

Three-phase UPS DELPHYS MX

from 250 to 900 kVA

AutomaticBypass

MaintenanceBypass

Rectifier

Charger

Inverter

Battery

Q4

Q5

Q3

Q20

Q1

Double conversion architecture

De

fyS

088

B G

B

Parallel architectures

STS 3

STS 1

STS 2

Load 1

Load 2

Load 3

DELPHYS MX

DELPHYS MX

To fulfil the most demanwding needs for power supply availability, for flexibility and for the installation to be upgraded.

• DELPHYS MX modular, growth without constraints (up to 6).

De

fyS

167

A

• DELPHYS MX centralised bypass, programmed growth.

De

fyS

168

B

• DELPHYS MX double bypass, for easier operation.

De

fyS

169

A

• DELPHYS MX with Stat ic Transfer Systems: IT SWITCH and STATYS to provide security as close to the applications as possible.

De

fyS

180

A G

B

De

fyS

093

AD

efy

S 0

94 A

De

fyS

059

B

64

Three-phase UPS DELPHYS MX

from 250 to 900 kVA

De

fyS

111

A G

B

Graphic display

Design adapted to the user: control panel with LeDs and LCD display.

Graphic touch screen (GTS)

The operator has access to the control functions with only a few intuitive touches of the screen.

Quick access to each installation module

Direct access zones to sub-unit menus

Status bar

Help menu for correct operation

UPS load rate (bar graph)

Access to installation mimic panel

De

fyS

102

A

Operating mode icons

Preventative maintenance request

Communication options

• Remote access panel.• ADC (Advanced Dry Contacts) data input

and output by dry contacts.• RS232, RS422, RS485 serial connection

JBUS / MODBUS, PROfIBUS.• MODBUS TCP interface (JBUS / MODBUS

tunneling).• NET VISION ethernet Network interface

(http web pages, email, SNMP, servers shutdown).

• Alarm notification via SMS.

Standard equipment

•  Slots for 7 communication cards.• Backfeed protection: detection circuit.• Standard interface  -  3  inputs  (emergency  stop,  generating 

set, battery protection) - 4 outputs (general alarm, back-up, bypass,

preventative maintenance needs).• EBS (expert Battery System).

Accessories

• BHC Interactive battery monitoring system.• Graphic touch screen.• ACS function for synchronisation with an

external source.• Reinforced IP protection degree.• Ventilation filters.• Ventilation control.

Remote maintenance

• T.SERVICE for continuous 24/7 monitoring via  the  SOCOMEC  UPS  maintenance service.

65

Three-phase UPS DELPHYS MX

from 250 to 900 kVA

UPS and batteries

A compact and integrated system.

De

fyS

181

A G

B

1930

845W2

Technical data

Sn [kVA] 250 300 400 500 800 900Pn [kW] 225 270 360 450 720 800RECTIFIER INPUTRated input voltage(1) 380/400/415 Vac

Voltage tolerance 340 to 460 V 360 to 460 VRated input frequency 50/60 HzFrequency tolerance ± 5 HzInput current distortion THDI at rated input current < 4.5% < 5%Input power factor 0.93 0.94

OUTPUTRated output voltage 380/400/415 VNominal output frequency 50/60 HzOutput frequency tolerance ± 0.2%Total output voltage distortion - linear load < 2%Total output voltage distortion - reference non-linear load (lEC 62043-3) < 4% < 3%

Short-circuit capability - 3.5 In 100 msOverload capabilìty 125% 10 min - 150% 1 minOutput power factor without derating in kVA or kW 0.9 lagging to 0.9 leading

BYPASSRated input voltage 380/400/415 VInput voltage tolerance ± 10%Rated input frequency 50/60 Hzlnput frequency tolerance ± 2 Hz (0.2 Hz to 4 Hz settable)

EFICIENCYNormal mode up to 93.5%ECO-MODE 98%

ENVIRONMENTAmbient storage temperature -20 °C to +70 °CAmbient service temperature 25 °C (recommended) ; 0 to 35 °C without deratingAltitude ≤ 1000 m without deratingRelative humidity range 95% max without condensationAcoustic noise at 1 m (ISO 3746)(2) ≤ 70 dBA ≤ 72 dBA ≤ 75 dBA

UPS CABINETDimensions (W x D x H) (mm) 1600 x 995 x 1930 3200 x 995 x 2210Weight (kg) 2300 2650 3000 5900Degree of protection (IEC 60529) IP20 standard

STANDARD COMPLIANCESafety IEC 62040-1; EN 62040-1; IEC 60950-1EMC IEC 62040-2; EN 62040-2Performance and test IEC 62040-3

Product comformity CE

(1) DELPHYS MX 250-500: three-phase 220-230-240 V on demand. (2) As per power range.

UPS Battery for back-up time Battery for back-up time Battery for back-up time5 minutes 10 minutes 15 minutes

UPS power Width Weight W2 Weight W2 Weight W2kVA / kW mm kg mm kg mm kg mm250 / 225 1600 - - 3670 2400 3770 2400300 / 270 1600 - - 3670 2400 4600 3200400 / 360 1600 - - 4890 3200 6110 4000500 / 450 1600 - - 5560 3200 7115 4800800 / 720 3200 7565 4800 9640 5000 - -900 / 800 3200 8735 4800 11568 6000 - -

De

fyS

087

A G

B

Central bypass cabinet

Coupling cabinet including the central static switch and the maintenance bypass.

1930

DWD

efy

S 0

86 A

GB

Power(1)

kVAW

mmD

mmWeight

kg300 600 800 270400 600 800 300600 1000 800 420800 1000 800 4501200 1200 800 6002000 2600 1200 21002400 4000 1245 N/D3200 5800 1245 N/D

(1) For other power ranges, please contact us.

Bypass transformer

for galvanic isolation.

1930

800W

Power(1)

kVAW

mmWeight

kg300 1000 800400 1200 1000500 1200 1500600 1200 1800800 1200 20001000 1200 25001200 1600 2700

(1) For other power ranges, please contact us.

www.socomec.comNon contractual document. © 2011, Socomec SA. All rights reserved.D

CG

_840

73

VALID FOR FRANCE VALID FOR ITALY

ISO 9001FM 28237

ISO14001EMS 553476