Upload
ngomien
View
213
Download
0
Embed Size (px)
Citation preview
Greiner vibrograf A.G.Weststrasse 69CH - 4900 LangenthalSwitzerland
Tel. ++41 62 923 44 33Fax ++41 62 923 18 46Email: [email protected]: www.greinervibrograf.com
Greiner
english
User ManualACS - 900
Helmut Klein GmbH.Steinenlandstrasse 1DE - 75181 PforzheimGermany
Tel. ++49 7231 9535 0Fax ++49 7231 9535 95 Greiner
User Manual ACS-900
Page 1Contents
Contents ------------------------------------------------
Introduction ACS-900 -------------------------------
Loading of the jars -----------------------------------
Fixed cleaning programs---------------------------
Select your own cleaning program-------------
Display explanation --------------------------------
Programming ------------------------------------------
Programming ------------------------------------------
Start cleaning program-----------------------------
Placing a password ---------------------------------
Help --------------------------------------------------------
Accessories --------------------------------------------
Baskets --------------------------------------------------
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13-19
User Manual ACS-900
Introduction ACS-900 Page 2
Unpack the ACS-900 and install it on the working place.Open the front doors and remove all packing material inside the instrument.
1. Main switch off.
2. Connect the ACS-900 with the delivered power-cable to the Power socket. Please observe the Voltage (230 or 115 Volts)marked on the label.
3. Switch on the main power switch. The basket - holder moves upwards, the turntable turns to Pos. 5 in front and the bracket of basket holder turns to front.
The Instrument is now in standby Position.
4. Press the „LOAD“ key on the keyboard to install the Ultrasound and the glass jars.
User Manual ACS-900
Standby Position = Position 5 of turnable is in front. Bracket of basket holderis in frontl. A arrow in the display is moving from left to right.The machine is ready to start.
Caution :
Do not place anything on top to the instrument that can block the ventilation
The ventilator fan that evacuates the fumes during the cleaning process from the machine is located on the top. When process is finished, ventilator stops automatically after 5 min.
Preparation of the baths
Pos. 1 = cleaning bath (with or without ultrasonic)Pos. 2 = cleaning bath or 1st rinsing bathPos. 3 = rinsing bathPos. 4 = cleaning or lubrication bathPos. 5 = remains empty (drying position)
Take care not to exceed the maximum level of fluids indicated on the jar and ultrasonic.(Quantity 0,55 l).
Page 3Loading of the jars
User Manual ACS-900
1. Press LOAD
2. Press ENTER
3. Put ultrasonic in Pos. 1
4. Press ENTER
5. Put jar in Pos. 2
6. Continue as discribed in point 2 till all the jars are installed
7. Press EXIT
8. Load the baskets with the parts youwant to clean, insert in lower basket-holder and close fixture.
9. The machine is ready for service.You can start a test.
for example: Programm 7
10. Press
11. Press
12. Press
Display shows :Next or Pos. 1 - 5Basket holder moves upwards.
Turntable turns to the Pos. 1If you operate 1,2,3,4 or 5 instead of ENTERthe turntable turns directly to the corresponding position.
If ultrasonic is not requested you can installa cleaning jar instead.
Turntable turns to the nex Position,Pos. 2
--
--ACS-900 change over to standby position.
--
--
Display says,Which clean program?
Display shows you datas in programm 7
Cleaning program 7 is running.
LOAD
ENTER
ENTER
EXIT
CLEAN
7
ENTER
Fixed cleaning programs Page 4
Buttons 7 8 9 are fixed programs (factory set).They can not be changed.
Descriptions of the programs :
Program 7
Cold air
7 > 3 0 - - 1 1 3 1 5 F 1 U
TIME MODE1 2 3 4 5 S US
Position turntableSpin drying time
Ultrasonic
Ultrasonic yes1 Minute
Cleaning timein minutes
Basketmovement typ Drying time
User Manual ACS-900
Program 8
8 > 3 0 - - 1 3 3 3 5 H 1 U
TIME MODE1 2 3 4 5 S US
Warm airPositions which are not used
Programm 9
9 > 5 0 2 5 - - 3 3 5 H 1 U
TIME MODE1 2 3 4 5 S US
Positions which are not used
Warm air
Page 5Select your own cleaning program
1 2 3
54 6Important: Button 1-6 can be used for cleaning procedures.
Programming of ACS 900 is possible in standby status or during cleaning program.
Explanation of the settings :
User Manual ACS-900
Time programming positions 1-5 ( 0 - 9 minutes )
0 = Position is inactiv1 - 9 basket stays in the jar between 1-9 minutes
Time
Acc
Movement typ of the basket 0 - 5
0 = Basket turns slowly in one direction half of the time and in the reverse direction the other half of the selected time. No agitation
1 = movements are very slowly and stretched 2 = movements are slowly and less strectched.3 = mean movements 4 = quick and short movement5 = very quick and very short movement.
Spin Spin 1 - 5 minutes
Spinning is effected in the upper part of the jars. Selected time is between 1 – 5 minutes.The selected time is for all jars.
Drying Drying (warm or cold)
H = warm air Switch on or off with button 1F = cold air
Remark : When jar (4) is selected, temperature of warm air is alreadyin the right position when basket runs for drying
US Ultrasound
Programming of ultrasound is effected with Pos. 1 of turntable. WithButton 1 you can switch on or off. Movement status 0 is suggestedduring cleaning with ultrasonic.
Page 6Display explanation
When you press key and 1 of the keys
the programs which were entered are shown on the display as you can see in the following example:
CLEAN 1 9
Cold air
1 > 3 0 - - 1 1 3 1 5 F 1 U
TIME MODE1 2 3 4 5 S US
Position turntableSpining time
Ultrasonic
Ultrasonic yes1 minute
Cleaning timein minutes
Basketmovement typ Drying time
Button-No.
User Manual ACS-900
Warm air
7 > 3 0 - - 1 1 3 1 5 H 1 -
TIME MODE1 2 3 4 5 S US
Position turntableSpining time
Ultrasonic
Ultrassonic no1 bis 5 minutes
Cleaning timeIn minutes
Basketmovement typ Drying time
button-No.
Programming Page 7
Key application display Indication Remark
PROG
ENTER
1
5
ENTER
0
ENTER
4
ENTER
1
ENTER
4
ENTER
2
ENTER6
3
ENTER
Which clean Program ?
1 > -- -- -- -- -- 1 -
Pos 1 > Time: # Acc: #
Pos 1 > Time: 5 Acc: #
Pos 1 > Time: 5 Acc: 0
Pos 2 > Time: # Acc: #
Pos 2 > Time: 4 Acc: #
Pos 2 > Time: 4 Acc: 1
Pos 3 > Time: # Acc: #
Pos 3 > Time: 4 Acc: #
Pos 3 > Time: 4 Acc: 2
Pos 4 > Time: # Acc: #
Pos 4 > Time: 6 Acc: #
Pos 4 > Time: 6 Acc: 3
Pos 5 > Time: 0
9
ENTER
Pos 5 > Time: 9
Time pos. 1
Movement typ
Time pos. 2
Movement typ
Time pos. 3
Movement typ
Time pos. 4
Movement typ
Time pos. 5
See next page
Which program ?
User Manual ACS-900
Programming with button 1 ( exampel)1 Page 8
Key application display indication Remark
1
ENTER
ENTER
ENTER
1
Fan : OFF 1. ONBy pressing button 1, fan for drying is activated ordeactivated.
ENTER Heat : OFF 1. ONBy pressing button 1,heat for drying is activated or deactivated.
Spin btwn stations : #
Spin btwn stations : 1
Spining time1 bis 5 minutes
US : OFF 1. ON By pressing button 1,ultrasonic is activated ordesactivated.
US : ON 1. OFF
EXIT > > > > > > > > > > > > > >Arrow to the right
PROG Which clean Program ? For controlling fixed programs.
1 > 5 0 4 1 4 2 6 3 9 H 1 U
TIME MODE1 2 3 4 5 S US1
Is cleaning program of button 1 correct ? If yes,1
EXIT > > > > > > > > > > > > > >
Programming of button is installed and stored.
Programming of button + can be done in the same
way. On page 5 you will find all the adjustments which are possible.
1
2 6
User Manual ACS-900
Start cleaning program Page 9
Key application Display indication
ENTER
1 9
CLEAN Which clean Program ?Press button
Press button Indication of the dates from the selected program.
Press button Cleaning program is startedand whole run time is Indicated.
Interruption Cleaning program:
You can interrupt cleaning at any time.
1. Press button BREAK
2. Press button EXIT
User Manual ACS-900
Placing a password Page 10
Only the person who knows the password is able to change the cleaning program.Any password can be used.Installation can be done during standby-modus or cleaning program.
Enter a password for the first time:
ENTER
ENTER
PROG
0
Key application Display indication Remark
ENTER
1 9
Which clean Program ?
Change password :
Enter new password :
Code, max. 8 digits
Enter your personalpassword
Enter new pw again : Enter new pw again
Now pw is installed andstored.
1 9
Difference, new try : In case of a mistake, enterright no.
Which program ?
Clear the password:
ENTER
0 Service, WELCOME !!!
The password is cleared
Welcome to the serviceprogram70
1
Key application Display indication Remark
User Manual ACS-900
Assistance Page 11
The ultrasonic does not work.
Please check if the ultrasonic is installed as follows:
ENTER
0
Key Display indication Remark
Service, WELCOME !!!
US uninst, 1, Toggle Ultrasonic is not installed
US inst, 1 , Toggle Ultrasonic is installed
US inst, 1 , Toggle Press button 1Indication is changing between US inst and US uninst
Welcome to the serviceprogram
70
3
Or
1
Press button 1 till display indication shows you (US inst, 1, Toggle).
exitPress button
Check and reinstall programs 1 to 6 as required.
User Manual ACS-900
Accessories Page 12
17142
Ultraschall
230 V = 17102110 V = 17101
US GeneratorPrint
User Manual ACS-900
17135
Glass jarbocal en verreGlaswanne
17136covercouvercleDeckel
17938Wave - breakerBrise - remousWellenbrecherfor basket up to ø 80pour panier jusqu‘à ø80für Korb bis ø 80