1 Programmable Controller Analog Terminal Block Conversion Module Programmable Controller High-Speed Counter Module Terminal Block Conversion Module Model FA-LTB40ADG FA-LTB40DAG FA-TB20TD FA-LTB40ADGN FA-LTB40TDG FA-TB20TC FA-LTB40ADDG FA-LTB40RD3G FA-LTB40D63P6V5 FA-LTB40D63P6V12 FA-LTB40D63P6V24 User’s Manual SAFETY PRECAUTIONS (Always read these precautions prior to use.) Before using this product, please read this manual carefully and pay full attention to safety to ensure that the product is used correctly. The precautions presented in this manual are concerned with this product only. For programmable controller system safety precautions, refer to the user’s manual of the programmable controller to be used. In this manual, the SAFETY PRECAUTIONS are ranked as “DANGER“ and “CAUTION“. DANGER Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in medium or minor injury and/or property damage. Note that failure to observe the CAUTION level instructions may lead to a serious consequence according to the circumstances. Always follow the precautions of both levels because they are important to personal safety. Please keep this manual in an easy-to-access location for future reference, and be sure to provide the manual to the end user. FA Go ds o

User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

1

Programmable Controller Analog Terminal Block Conversion Module

Programmable Controller High-Speed Counter Module Terminal Block Conversion Module

Model FA-LTB40ADG FA-LTB40DAG FA-TB20TD FA-LTB40ADGN FA-LTB40TDG FA-TB20TC FA-LTB40ADDG FA-LTB40RD3G FA-LTB40D63P6V5 FA-LTB40D63P6V12 FA-LTB40D63P6V24 User’s Manual

SAFETY PRECAUTIONS

(Always read these precautions prior to use.)

Before using this product, please read this manual carefully and pay full attention to safety

to ensure that the product is used correctly.

The precautions presented in this manual are concerned with this product only. For

programmable controller system safety precautions, refer to the user’s manual of the

programmable controller to be used. In this manual, the SAFETY PRECAUTIONS

are ranked as “DANGER“ and “CAUTION“.

DANGER Indicates that incorrect handling may cause hazardous

conditions, resulting in death or severe injury.

CAUTION

Indicates that incorrect handling may cause hazardous

conditions, resulting in medium or minor injury and/or

property damage.

Note that failure to observe the CAUTION level instructions may lead to a serious

consequence according to the circumstances. Always follow the precautions of both levels

because they are important to personal safety.

Please keep this manual in an easy-to-access location for future reference, and be sure to

provide the manual to the end user.

FA Go dso

Page 2: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

2

[Installation Precautions]

CAUTION Use this module in an environment that complies with the general specifications

described in the catalog. Use in an environment outside the scope of general

specifications may result in risk of electric shock, fire, malfunction, product damage,

and deterioration.

During installation, be sure to fully secure the module using a DIN rail or mounting

screws and fully tighten the screws to the specified torque. Loosely tightened screws

results in the risk of the module dropping and malfunction.

Be careful to prevent foreign matter such as dust or wiring chips from entering the

module. Failure to do so may result in the risk of fire, failure, and malfunction.

Do not touch a powered terminal. Doing so results in the risk of malfunction.

Do not directly touch a powered section of the module. Doing so results in the risk of

module failure and malfunction.

[Wiring Precautions]

DANGER Be sure to shut off all phases of the external power supply used by the system

before installation or wiring work. Failure to do so results in the risk of electric shock,

module failure, and malfunction.

CAUTION Be sure to ground the FG terminal by applying class D grounding (class 3 grounding)

or higher. Failure to do so results in the risk of electric shock and malfunction.

Correctly wire cables to the module after checking the rated voltage and terminal

layout of the product. Connecting a power supply having a different rating or wiring

the module incorrectly results in the risk of fire and malfunction.

When wiring the input signal line and output signal line, do not bind the line with or

have the line contact wiring having superimposed noise. Doing so results in the risk

of malfunction.

Tighten the terminal screws within the range of the specified torque. If a screw is too

loose, a short circuit, or malfunction may result. If a screw is too tight, screw and/or

module damage may result, causing the module to drop, a short circuit, or

malfunction.

Page 3: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

3

[Startup and Maintenance Precautions]

DANGER Do not touch a terminal while the module is powered. Doing so results in the risk of electric

shock and malfunction.

Be sure to turn the power OFF before cleaning the module or retightening terminal screws.

Failure to do so results in the risk of module failure and malfunction.

CAUTION Do not disassemble or modify the module. Doing so results in the risk of failure, malfunction,

injury, and fire.

Be sure to shut off all phases of the external power supply module installation or removal.

Failure to do so results in the risk of electric shock, module failure, and malfunction.

[Disposal Precautions]

DANGER At the time of disposal, treat the product as industrial waste.

Page 4: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

4

INTRODUCTION

Thank you for purchasing the FA Goods programmable controller analog terminal block conversion

module and programmable controller high-speed counter module terminal block conversion module.

Before using the product, please read this manual carefully to ensure correct and effective use.

1. PERFORMANCE SPECIFICATIONS

FA-LTB40TDG

Thermocouple input terminal block conversion module Model name Item FA-LTB40TDG

Connectable module (Note 1) Q68TD-G-H01, Q68TD-G-H02

Connectable cable (Note 2) FA-CBL**Q68TDG

Applicable wire: 0.5 to 1.25mm2 (conform to JIS C 2811 ) However, a 0.3 to 2mm2 cable is connectable by using an applicable crimping terminal.

Operating voltage: 8VDC or less, operating current: 1mA or less

Terminal screw tightening torque range: 50 to 75N・cm (5.2 to 7.6kgf・cm)

Terminal block (regular screws)

Terminal block screw: M3 screw

Mounting screws M4 (with plain washer) x 0.7mm x 8mm or greater

Tightening torque range: 78 to 118N・cm (8 to 12kgf・cm) Module

mounting DIN rail Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (conform to JIS C 2812)

Dielectric withstand voltage Between analog input CHs: 1000VAC for 1 minute; Other: 500VAC for 1 minute

Insulation resistance (initial) 10MΩ or more by 500VDC insulation resistance tester

Weight About 200g Note 1: Applies to the programmable controller MELSEC-Q series manufactured by Mitsubishi Electric Corporation. Note 2: The two asterisks (**) indicate cable length (05: 0.5m, 10: 1m, 20: 2m, 30: 3m).

FA-TB20TD

Thermocouple input terminal block conversion module Model name Item FA-TB20TD

Connectable module (Note 1) Q64TD、Q64TDV-GH A1S68TD

Connectable cable (Note 2) FA-CBLQ64TD** FA-CBLS68TD**

Applicable wire: 0.5 to 1.25mm2 (conform to JIS C 2811) However, a 0.3 to 2mm2 cable is connectable by using an applicable crimping terminal.

Operating voltage: 5VDC or less operating current: 1mA or less

Terminal block screw: M3 screw

Terminal screw tightening torque range: 58.8 to 88.2N・cm (6 to 9kgf・cm)

Terminal block (Captive screws)

Terminal block screw pull force (axial direction): 78.4N or greater

Mounting screws M4 x 0.7mm x 22mm or greater, tightening torque range: 78 to 118N・cm (8 to 12kgf・

cm) Module

mounting DIN rail Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (conform to JIS C 2812)

Dielectric withstand voltage 1500VAC (50/60Hz) for 1 minute

Insulation resistance (initial) 100MΩ or more by 500VDC insulation resistance tester

Weight 125g Note 1: Applies to the programmable controller MELSEC-Q series and AnS series manufactured by Mitsubishi Electric

Corporation. Note 2: The two asterisks (**) indicate cable length (05: 0.5m, 10: 1m, 15:1.5m, 20: 2m, 25:2.5m, 30: 3m).

Page 5: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

5

FA-TB20TC

Temperature control terminal block conversion module Model name Item FA-TB20TC

Connectable module (Note 1) Q64TCTT, Q64TCTTBW A1S64TCTRT, A1S64TCTRTBW

Connectable cable (Note 2) FA-CBLQ64TC** FA-CBLS64TCTR**

Applicable wire: 0.5 to 1.25mm2 (conform to JIS C 2811) However, a 0.3 to 2mm2 cable is connectable by using an applicable crimping terminal.

Operating voltage: 30VDC or less; Operating current: 400mA or less (common), 100mA or less (signal)

Terminal block screw: M3 screw

Terminal screw tightening torque range: 58.8 to 88.2N・cm (6 to 9kgf・cm)

Terminal block (Captive screws)

Terminal block screw pull force (axial direction): 78.4N or greater

Mounting screws M4 x 0.7mm x 22mm or greater, tightening torque range: 78 to 118N・cm (8 to 12kgf・

cm) Module

mounting DIN rail Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (conform to JIS C 2812)

Dielectric withstand voltage 1500VAC (50/60Hz) for 1 minute

Insulation resistance (initial) 100MΩ or more by 500VDC insulation resistance tester

Weight 125g Note 1: Applies to the programmable controller MELSEC-Q series and AnS series manufactured by Mitsubishi Electric

Corporation. Note 2: The two asterisks (**) indicate cable length (05: 0.5m, 10: 1m, 15: 1.5m, 20: 2m, 25:2.5m, 30: 3m).

FA-LTB40RD3G

RTD input terminal block conversion module Model name Item FA-LTB40RD3G

Connectable module (Note 1) Q68RD3-G

Connectable cable (Note 2) FA-CBL**Q68RD3G

Applicable wire: 0.5 to 1.25mm2 (conform to JIS C 2811) However, a 0.3 to 2mm2 cable is connectable by using an applicable crimping terminal.

Operating voltage: 8VDC or less, operating current: 1mA or less

Terminal screw tightening torque range: 50 to 75N・cm (5.2 to 7.6kgf・cm)

Terminal block (Regular screws)

Terminal block screw: M3 screw

Mounting screws M4 (with plain washer) x 0.7mm x 8mm or greater

Tightening torque range: 78 to 118N・cm (8 to 12kgf・m) Module

mounting DIN rail Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (conform to JIS C 2812)

Dielectric withstand voltage Between analog input CHs: 1000VAC for 1 minute, Other: 500VAC for 1 minute

Insulation resistance (initial) 10MΩ or more by 500VDC insulation resistance tester

Weight About 200g Note 1: Applies to the programmable controller MELSEC-Q series manufactured by Mitsubishi Electric Corporation. Note 2: The two asterisks (**) indicate cable length (05: 0.5m, 10: 1m, 20: 2m, 30: 3m).

Page 6: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

6

FA-LTB40ADG, FA-LTB40ADGN, FA-LTB40ADDG, FA-LTB40DAG Q68AD-G

conversion module Q66AD-DG

conversion module Q66DA-G

conversion module Model name

Item FA-LTB40ADG FA-LTB40ADGN FA-LTB40ADDG FA-LTB40DAG

Connectable module (Note 1) Q68AD-G Q66AD-DG Q66DA-G

Connectable cable (Note 2) FA-CBL**Q68ADG FA-CBL**Q68ADGN FA-CBL**Q66ADDG FA-CBL**Q66DAG

Applicable wire: 0.5 to 1.25mm2 (conform to JIS C 2811) However, a 0.3 to 2mm2 cable is connectable by using an applicable crimping terminal.

Terminal screw tightening torque range: 50 to 75N・cm (5.2 to 7.6kgf・cm)

Terminal block (Regular screws)

Terminal block screw: M3 screw

Operating voltage 10VDC 10VDC 24VDC 24VDC

Operating current 30mA or less 30mA or less 360mA or less 220mA or less

Mounting screws M4 (with plain washer) x 0.7mm x 8mm or greater

Tightening torque range: 78 to 118N・cm (8 to 12kgf・cm) Module

mounting DIN rail Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (conform to JIS C 2812)

Connector MIL40P

Dielectric withstand voltage Between CHs: 1000VAC for 1 minute, Other: 500VAC for 1 minute

Insulation resistance (initial) 10MΩ or more by 500VDC insulation resistance tester

Weight About 200g Note 1: Applies to the programmable controller MELSEC-Q series manufactured by Mitsubishi Electric Corporation. Note 2: The two asterisks (**) indicate cable length (05: 0.5m, 10: 1m, 20: 2m, 30: 3m).

FA-LTB40D63P6V5, FA-LTB40D63P6V12, FA-LTB40D63P6V24

QD63P6 terminal block conversion module 5V signal input 12V signal input 24V signal input

Model name

Item FA-LTB40D63P6V5 FA-LTB40D63P6V12 FA-LTB40D63P6V24

Connectable module (Note 1) QD63P6

Connectable cable (Note 2) FA-CBL**QD63P6

Applicable line: 0.5 to 1.25mm2 (conform to JIS C 2811) However, a 0.3 to 2mm2 cable is connectable by using an applicable crimping terminal.

Terminal screw tightening torque range: 50 to 75N・cm (5.2 to 7.6kgf・cm)

Terminal block (Regular screws)

Terminal block screw: M3 screw

Voltage 5V±10% 12V±10% 24V±10%

Counter input signal Current 6.4 to 11.5mA 10.8 to 15.9mA 10.5 to 14.9mA

Connectable encoder Open collector output CMOS voltage output

Open collector output Open collector output

Mounting screws M4 (with plain washer) x 0.7mm x 8mm or greater

Tightening torque range: 78 to 118N・cm (8 to 12kgf・cm) Module

mounting DIN rail Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (conform to JIS C 2812)

Dielectric withstand voltage 500VAC for 1 minute

Insulation resistance (initial) 10MΩ or more by 500VDC insulation resistance tester

Weight About 200g Note 1: Applies to the programmable controller MELSEC-Q series manufactured by Mitsubishi Electric Corporation. Note 2: The two asterisks (**) indicate cable length (05: 0.5m, 10: 1m, 15:1.5m, 20: 2m).

Page 7: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

7

Module mounting hole

Module mounting hole

Cable connector 191 181 169

29

7.62

47

18

(44.7)

(4) 14.3 5.5

Simple lock (120 ) °

DIN rail

Input terminal block

41.5 (3.2)

Module mounting hole

Module mounting hole

Cable connector

Input terminal block

Simple lock(120 )

104

67.5

94

Cold junction compensatingresistor (supplied)

DIN rail

°

(5) 52-φ4.5

2-φ8

7.62 12

16

50

5

(32)15

35.5

6

8.5

FA-TB20TD

FA-TB20TD

Q64TD/Q64TDV-GH

A1S68TD

Cable length: LQ68TD-G-H01 G68TD-G-H02 Connection side connector

FA-LTB40TDGConnection sideconnector

Shielded cable (with M4 round crimping terminal) Shielded cable (with M4 round crimping terminal) (300)

(18)

SLD

φ7.

4

(50) (6)

(55.

3)

(300)

SLD

FA-TB20TD Connection side connector

Q64TD/Q64TDV-GH Connection side terminal block Cable length: L

8

(30)

φ10

.0 (50)

(22.8) (12.23)

(51.03)

FA-TB20TD Connection side connector

A1S68TD Connection side terminal block Cable length: L

10 φ

10.0

(50)

(22.8)

(51.

03)

(30)

(12.23)

2. EXTERNAL DIMENSIONS [unit: mm]

Insulated thermocouple input terminal block conversion module

(FA-LTB40TDG)

Thermocouple input terminal block conversion module

(FA-TB20TD)

Thermocouple input dedicated cable

(For FA-CBL**Q68TDG MELSEC-Q series)

(For FA-CBLQ64TD** MELSEC-Q series)

(For FA-CBLS68TD** MELSEC-AnS series)

Page 8: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

8

FA-TB20TC Connection side connector

FA-TB20TC Connection side connectorA1S64TCTRT/A1S64TCTRTBW

Connection side terminal block

Q64TCTT/Q64TCTTBW Connection side terminal block

Module mounting hole

Cable connector

°

DIN rail

Input terminal block

104 94 (5) 5

Simple lock(120 )

2-φ4.5

12 7.62

16

50

2-φ8

5

(32)15

6 35

.5

8.5

(3.2)41.5

Shielded wire (with round crimping terminal)

Cable length: L

8

φ10

.0

(50)

(22.8)

(51.

03)

(30) (150)

(12.23)

Cable length: L

10

(30)

(150)

φ10

.5 (50)

(22.8) (12.23)

(51.

03)

FG

Module mounting hole

Module mounting hole

Module mounting hole Cable connector

191 181 169

29

7.62

47

18

(44.7)

(4) 14.3 5.5

Simple lock(120 ) °

DIN rail

Input terminal block

Cable length: L

Shielded wire (with M4 round crimping terminal) Shielded wire (with M4 round crimping terminal) (300)

(18)

SLD

φ7.

4

(50) (6)

(55.

3)

(300)

SLD

Q68RD3-G Q68AD-G Q66AD-DG Q66DA-G Connection side connector

FA-LTB40RD3GFA-LTB40ADG FA-LTB40ADGN FA-LTB40ADDG FA-LTB40DAG Connection side connector

Temperature control terminal block conversion module [Unit: mm]

(FA-TB20TC)

Temperature control cable with terminal block

(For FA-CBLQ64TC** MELSEC-Q series)

(For FA-CBLS64TCTR** MELSEC-AnS series)

Insulated analog module terminal block conversion module, insulated RTD input module terminal

block conversion module (FA-LTB40ADG/ADGN/ADDG/DAG, FA-LTB40RD3G)

Connection cable (FA-CBL**Q68ADG, FA-CBL**Q68ADGN, FA-CBL**Q66ADDG,

FA-CBL**Q66DAG, FA-CBL**Q68RD3G)

Page 9: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

9

Module mounting hole

Module mounting hole Cable connector Input terminal block

191 181 169

29

7.62

47

18

(44.7)

(4)

14.3 5.5Simple lock

(120 ) °

DIN rail

(50) (6)

(55.

3)

(200)

FG(7

.4)

FA-LTB40D63P6V**Connection side connector

QD63P6 Connection side connector

High-speed counter module terminal block conversion module [Unit: mm]

(FA-LTB40D63P6V5/V12/V24)

Connection cable (FA-CBL**QD63P6)

High-speed counter module terminal block conversion module dedicated cable connection example

Phase A

Phase B

Phase B pulse input +

Phase A pulse input +

Phase A pulse input -

Phase B pulse input -

Twisted shielded cable

Twisted shielded cable

Shield

Shield

Pulse generating device

5V signal 12V signal24V signal

5V signal 12V signal24V signal

Signal GND

Signal GND

**

Cable length: L

Page 10: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

10

3. INSTALLATION METHOD

3-1 Connecting the Connection Cable and Terminal Block Conversion Module with MELSEC-Q Series

For MELSEC-Q series module with insulation between channels

(Q68AD-G, Q66AD-DG, Q66DA-G, Q68TD-G-H01, Q68TD-G-H02, Q68RD3-G)

Voltage/Current input/output Dual wire transmitter input Thermocouple input RTD input

Mitsubishi Electric Corporation MELSEC-Q series module with insulation between channels Q68AD-G Q66AD-DG Q66DA-G Q68TD-G-H01 Q68TD-G-H02 Q68RD3-G

Q68TD-GRUN

ERR. ALM

Q68TD-G

Connection cableFA-CBL**Q68ADG

**Q66ADDG

FA-CBL**Q68ADGN FA-CBL FA-CBL**Q66DAG FA-CBL**Q68TDG FA-CBL**Q68RD3G

Terminal block conversion module FA-LTB40ADG FA-LTB40ADGNFA-LTB40ADDGFA-LTB40DAG FA-LTB40TDG FA-LTB40RD3G

Ground the FG wire in the same manner as the programmable controller module.

Ground the FG wire in the same manner as the programmable controller module.

Insert the connector to the back, and then fully secure the connector with the clip.

Insert the connector to the back, and then fully install the connector to the programmable controller module using the mounting screws.

Page 11: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

11

For MELSEC-Q series thermocouple input module For MELSEC-AnS series thermocouple input module

[Q64TD, Q64TDV-GH, Q64TCTT (BW)] [A1S68TD, A1S64TCTRT (BW)]

Thermocouple input Temperature control input/output

MELSEC-Q seriesthermocouple inputmodule manufacturedby Mitsubishi ElectricCorporationQ64TDQ64TDV-GHQ64TCTT(BW)

Terminal block conversion moduleFA-TB20TD FA-TB20TC

Q64TD RUN ERR.

Q64TD

Connection cable FA-CBLQ64TD** FA-CBLQ64TC**

Terminal block conversion module FA-TB20TD FA-TB20TC

Connection cable FA-CBLS68TD** FA-CBLS64TCTR**

MELSEC-AnS seriesthermocouple inputmodule manufacturedby Mitsubishi ElectricCorporationA1S68TDA1S64TCTRT(BW)

Fully install the terminal block to the programmable controller module using the mounting screws.

Fully insert and secure the connector until you hear a click.

Ground the FG wire in the same manner as the programmable controller module.(FA-CBLQ64TC** only.)

Fully insert and secure the connector until you hear a click.

Fully install the terminal block to the programmable controller module using the mounting screws.

Ground the FG wire in the same manner as the programmable controller module.(FA-CBLS64TCTR** only.)

Thermocouple input Temperature control input/output

Page 12: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

12

For MELSEC-Q series high-speed counter module (QD63P6)

5V 12V Pulse input 24V

MELSEC-Q series counter module manufactured by Mitsubishi Electric Corporation QD63P6

QD63P6RUN

ERR.

φA φB

1 2 3 4 5 6 CH

QD63P6

Terminal block conversion module FA-LTB40D63P6V5 FA-LTB40D63P6V12 FA-LTB40D63P6V24

Connection cableFA-CBL**QD63P6

FA-LTB40D63P6V5

Insert the connector to the back, and then fully secure the connector with a clip.

Ground the FG wire in the same manner as the programmable controller module.

Insert the connector to the back, and then fully install the connector to the programmable controller module using the mounting screws.

Page 13: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

13

3-2 Connecting the Terminal Block Conversion Module and External Devices

FA-LTB40ADG 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

CH1 V+

- CH2 V+

CH2 V-/I-

- CH3V+

CH3 I+

- - CH4V-/I-

- CH5V+

CH5I+

- CH6V-/I-

- CH7 V+

CH7 I+

- CH8V-/I-

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

CH1 V-/I-

CH1 I+

- CH2

I+ -

CH3 V-/I-

- - CH4V+

CH4I+

- CH5V-/I-

- CH6V+

CH6I+

- CH7 V-/I-

- CH8V+

CH8I+

V+

V-/I-

I+ V+

V-/I-

I+

Current input Voltage input

I- V+ V-I+ FA-LTB40ADGN

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39CH1 V+

CH1 Is

CH2 V+

CH2 Is

- CH3V+

CH3 Is

CH4 V+

CH4Is

- CH5V+

CH5Is

CH6V+

CH6Is

- CH7 V+

CH7 Is

CH8 V+

CH8Is

-

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

CH1 V-/I-

CH1 I+

CH2 V-/I-

CH2 I+

- CH3 V-/I-

CH3 I+

CH4 V-/I-

CH4I+

- CH5V-/I -

CH5I+

CH6V-/I-

CH6I+

- CH7 V-/I-

CH7 I+

CH8V-/I-

CH8I+

-

V+

V-/I-

Is V+

V-/I-

Is

Current input(Note 1) Voltage input(Note 2)

I- V+ V-I+

I+ I+

FA-LTB40ADDG

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 CH1

P I-

/CHK -

CH2 P

I- /CHK

- CH3

P I-

/CHK -

CH4P

I- /CHK

- CH5

P I-

/CHK-

CH6 P

I- /CHK

- - DC24V

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

I+ /CHK

- - I+

/CHK - -

I+ /CHK

- - I+

/CHK- -

I+ /CHK

- - I+

/CHK - - - DC24G

P I-/CHK P I-/CHK

Dual wire transmitter input Current input

I+ I-+ - + -VDual wire

transmitter

I+/CHK I+/CHK

FA-LTB40DAG 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

CH1 V+

CH1 I+

- CH2 V+

CH2 I+

- CH3 V+

CH3 I+

- CH4V+

CH4I+

- CH5V+

CH5I+

- CH6 V+

CH6 I+

- - DC24V

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

COM1 - - COM2 - - COM3 - - COM4 - - COM5 - - COM6 - - - DC24G

V+

COM

I+ V+

COM

I+

Voltage output Current output

V- I+I-V+

Input1 Input2 Input3 Input4 Input5 Input6 Input7 Input8

Input1 Input2 Input3 Input4 Input5 Input6 Input7 Input8

Note 1: For current input, connect the (V+) and (Is) terminals. The screw terminal block short circuit bar FA-BAR20P can be used for the above connection. (For screw terminal block short circuit bar details, refer to our catalog.)

Note 2: For voltage input, set the (Is) and (I+) terminals as NC, and do not connect external wiring.

Input1 Input2 Input3 Input4 Input5 Input6 24VDC

Output1 Output2 Output3 Output4 Output5 Output6 24VDC

Page 14: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

14

FA-LTB40TDG 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

CH1 +

- CH2

+ -

CH3 +

- CH4

+ -

CH5+

- CH6

+ -

CH7+

- CH8

+ - - - -

RTDG

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

CH1 -

- CH2

- -

CH3 -

- CH4

- -

CH5-

- CH6

- -

CH7-

- CH8

- - - -

RTD+

RTD-

+

- RTD+

RTDG

RTD-

Thermocouple input RTD input

-+ RTD

(Note1)

(Note1)

FA-LTB40RD3G 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

CH1 A1

CH1 b1

- CH2 B2

- CH3A3

CH3 b3

- CH4B4

- CH5A5

CH5b5

- CH6B6

- CH7 A7

CH7 b7

- CH8B8

-

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

CH1 B1

- CH2 A2

CH2 b2

- CH3 B3

- CH4 A4

CH4b4

- CH5B5

- CH6A6

CH6b6

- CH7 B7

- CH8A8

CH8b8

-

A

B A

B

b

RTD input

BA

b

b BA b

FA-TB20TD(With Q64TD and Q64TDV-GH connection) FA-TB20TD(With A1S68TD connection)

1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19

- - - SLD CH2

+ CH2

- CH4

+ CH4

- SLD -

CH1+

CH1-

CH2+

CH2-

CH4 +

CH4 -

CH6 +

CH6-

CH8+

CH8-

2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20

RTD +

RTD -

SLD CH1

+ CH1

- CH3

+ CH3

- SLD - -

RTD+

RTD-

CH3+

CH3-

CH5 +

CH5 -

CH7+

CH7-

SLD SLD

+ -

RTD+ RTD-

Thermocouple input RTD input

-+ RTD (Note2)

FA-TB20TC(With Q64TCTT(BW) connection)

1 3 5 7 9 11 13 15 17 19

L1 L3 COM

- CH1

+ CH1

- - -

CH3 +

CH3-

-

2 4 6 8 10 12 14 16 18 20

L2 L4 - CH2

+ CH2

- - -

CH4 +

CH4-

-

Input1 Input2 Input3 Input4 Input5 Input6 Input7 Input8 RTD

Input1 Input2 Input3 Input4 Input5 Input6 Input7 Input8

· Install the module in a location having a constant ambient temperature. · Connect the thermocouple or compensation lead wire directly to the terminal

block. Note 1: For the cold junction compensating resistor (RTD), connect the supplied

Q68TD-G-H01 and -H02 products to terminal numbers 38 and 40 as illustrated above. Terminal number 38 (RTD G) and terminal number 40 (RTD -) are connected inside the conversion module, and therefore do not require external wiring.

RTD Input1 Input3 RTD Input3 Input5 Input7

Input2 Input4 Input1 Input2 Input4 Input6 Input8

· Install the module in a location having a constant ambient temperature. · Connect the thermocouple or compensation lead wire directly to the terminal block. · For FA-CBLQ64TD** and FA-CBLS68TD**, a ground wire is not wired. Grounding with

FA-TB20TD is not possible. Ground Q64TD with terminal number 18 of the programmable controller module side terminal block of FA-CBLQ64TD. Ground A1S68TD with terminal number 20 of the programmable controller module side terminal block of FA-CBLS68TD**.

Note 2: The cold junction compensating resistor (RTD) is supplied with FA-TB20TD.

Control output Input2 Input4

Input1 Input3 + -

Thermocouple input

-+

· Install the module in a location having a constant ambient temperature.

· Connect the thermocouple or compensation lead wire directly to the terminal block.

· The cold junction compensating resistor (RTD) is built into FA-TB20TC.

Control output

Page 15: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

15

FA-TB20TC(With A1S64TCTRT(BW) connection FA-TB20TC (with A1S64TCTRT (BW) connection : Standard Control (thermocouple)) : Heating and cooling Control (thermocouple))

1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19

L1 L3 COM

- -

CH1 +

CH1-

- - CH3

+ CH3

- L1H L2H

COM-

- MT1

+ MT1

- - -

MT2+

MT2-

2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20

L2 L4 - CH2

+ CH2

- - - -

CH4+

CH4-

L1C L2C - CH1

+ CH1

- - - -

CH2+

CH2-

+ -

Thermocouple inputMonitor input

-+

FA-TB20TC (With A1S64TCTRT (BW) connection FA-TB20TC (With A1S64TCTRT (BW) connection : Standard control (platinum RTD)) : Heating and cooling control (platinum RTD))

1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 11 13 15 17 19

L1 L3 COM

- CH1

A CH1

B CH1

b -

CH3 A

CH3B

CH3b

L1H L2HCOM

- MT1

A MT1

B MT1

b -

MT2A

MT2B

MT2b

2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20

L2 L4 CH2

A CH2

B CH2

b - -

CH4 A

CH4B

CH4b

L1C L2CCH1

A CH1

B CH1

b - -

CH2A

CH2B

CH2b

BA b

A B

Platinum RTD input Monitor input

b

FA-LTB40D63P6V5 (For 5V signal) 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

- CH1 A+(5)

CH1 B+(5)

- CH2 A+(5)

CH2B+(5)

- CH3 A+(5)

CH3B+(5)

- CH4A+(5)

CH4B+(5)

- CH5A+(5)

CH5B+(5)

- CH6 A+(5)

CH6 B+(5)

- -

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

- CH1 A-

CH1 B-

- CH2 A-

CH2 B-

- CH3 A-

CH3B-

- CH4A-

CH4B-

- CH5A-

CH5B-

- CH6 A-

CH6B-

- -

FA-LTB40D63P6V12 (For 12V signal) 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

- CH1

A+(12) CH1

B+(12) -

CH2 A+(12)

CH2B+(12)

- CH3

A+(12) CH3

B+(12)-

CH4A+(12)

CH4B+(12)

- CH5

A+(12)CH5

B+(12)-

CH6 A+(12)

CH6 B+(12)

- -

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

- CH1 A-

CH1 B-

- CH2 A-

CH2 B-

- CH3 A-

CH3B-

- CH4A-

CH4B-

- CH5A-

CH5B-

- CH6 A-

CH6B-

- -

FA-LTB40D63P6V24 (For 24V signal) 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

- CH1

A+(24) CH1

B+(24) -

CH2 A+(24)

CH2B+(24)

- CH3

A+(24) CH3

B+(24)-

CH4A+(24)

CH4B+(24)

- CH5

A+(24)CH5

B+(24)-

CH6 A+(24)

CH6 B+(24)

- -

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

- CH1 A-

CH1 B-

- CH2 A-

CH2 B-

- CH3 A-

CH3B-

- CH4A-

CH4B-

- CH5A-

CH5B-

- CH6 A-

CH6B-

- -

Input2 Control output Input4

Input1 Input3Control output

Control output Input1 Input2

Monitor Input1 Monitor Input2Control output

· Install the module in a location having a constant ambient temperature. · Connect the thermocouple or compensation lead wire directly to the terminal block. · The cold junction compensating resistor (RTD) is built into FA-TB20TC.

Input2 Control output Input4

Input1 Input3Control output

Control output Input1 Input2

MonitorInput1 MonitorInput2Control output

· Install the module in a location having a constant ambient temperature. · Connect the thermocouple or compensation lead wire directly to the terminal block. · The cold junction compensating resistor (RTD) is built into FA-TB20TC.

Input1 Input2 Input3 Input4 Input5 Input6

Input1 Input2 Input3 Input4 Input5 Input6

Input1 Input2 Input3 Input4 Input5 Input6

Page 16: User’s Manual - MEE · 4 INTRODUCTION Thank you for purchasing the FA Goods programmable controller analog terminal block conversion module and programmable controller high-speed

16

A+

A-

B+

Pulse input

+ -

B-

+ -Phase A Phase B

4. USAGE PRECAUTIONS

(1) For wiring to the terminal block, refer to the manual of the programmable controller module to be

connected, published by Mitsubishi Electric Corporation.

(2) Ground the FG wire provided with the cable in the same manner as the programmable controller

module. Note that rolling up extra wire without grounding the wire may cause the wire to function

as an antenna, resulting in the risk of noise.

For Your Safety This product has been manufactured as a general-purpose product for general industry

applications, etc. The product is not intended for use in devices or systems used under

conditions in which human life could be greatly affected.

When considering application of this product to special applications, such as nuclear power,

electrical power, aerospace, medical, or manned transport devices or systems, contact our

sales service desk.

Although this product was manufactured under a strict quality management system, the product

shall be systematically provided with backup and fail-safe functions when applied to equipment

that may lead to a major accident or damage in the unlikely event any failure or defect should

occur in the product.

MITSUBISHI ELECTRIC ENGINEERING CO., LTD. 1-13-5 Kudankita, Chiyoda-ku, Tokyo, Japan 102-0073 Homepage URL: http://www.mee.co.jp/

Direct any technical inquiries to: Nagoya office (PC Engineering Dept.) Phone: +81 (52) 723-8058 Fax: +82 (52) 723-8062

During product use, be sure to ensure safety in the unlikely event failure occurs. Mitsubishi Electric Engineering assumes no responsibility whatsoever for any secondary damage caused by the failure of this product.

50D-FB0035 (0906) MEE Information such as specifications is subject to change without notice.

Developed June 2009