4
TECHNICAL DATASHEET Aquashield MAX UV Pressure System Model Numbers: ASHS60-08T, ASHM60-10T, ASHS60-08RB, ASHM60-10RB UV Applications • Pressure boosting and disinfection of rainwater • Large home potable water supply • School shower and toilet blocks • Guest house potable water supply Benefits of Microlene's Aquashield Packaged UV Pressure System Davey’s proven 3 stage water disinfection & filtration process will ensure a safe and hygienic water supply*. Factory matched and tested package ensures the correct UV dosage is delivered with high reliability. Suitable for both tank only and mains water back-up installations, and for bore and surface water treatment – subject to water quality. Pump interlock detects lamp failure and locks pump out ensuring only disinfected water is delivered. Lamp count down timer with set limit of 9000 hours (1 year) matches lamp life and ensures only disinfected water is delivered. Durable UV resistant cover allows for flexible, vandal resistant, exterior installation. RainBan ® k MKII controller option • Provides seamless automatic mains water back-up and source indication • Automatically reverts to mains water if power fails or pump is removed Torrium ® 2 TT70 controller option • Intelligent automatic pump control maximises pump efficiency by adjusting run on time and cut in pressures High efficiency Steriflo UV disinfection system with low pressure lamp and test tube quartz sleeve for easy cleaning and high performance. 20 micron Filterpure pre-filtration for long cleaning intervals with dirt, rust, sediment and debris reduction. 1 micron Filterpure filtration for parasitic cyst reduction and further sediment reduction to reduce ‘shadowing’ of bacteria and viruses. *Cannot treat water contaminated by metals, chemicals, algal toxins or radiation Roof Tank Pump Valve Coarse Filtration Fine Filtration UV Disinfection Valve 1 2 3

UV Aquashield MAX UV Pressure System - Microlene · TECHNIAL ATASHEET Aquashield MAX UV Pressure System Model Numbers: ASHS60-08T, ASHM60-10T, ASHS60-08RB, ASHM60-10RB UV Applications

Embed Size (px)

Citation preview

TECHNICAL DATASHEET

Aquashield MAXUV Pressure SystemModel Numbers: ASHS60-08T, ASHM60-10T, ASHS60-08RB, ASHM60-10RB

UV

Applications• Pressure boosting and disinfection of rainwater

• Large home potable water supply

• School shower and toilet blocks

• Guest house potable water supply

Benefits of Microlene's Aquashield Packaged UV Pressure System

Davey’s proven 3 stage water disinfection & filtration process will ensure a safe and hygienic water supply*.

Factory matched and tested package ensures the correct UV dosage is delivered with high reliability.

Suitable for both tank only and mains water back-up installations, and for bore and surface water treatment – subject to water quality.

Pump interlock detects lamp failure and locks pump out ensuring only disinfected water is delivered.

Lamp count down timer with set limit of 9000 hours (1 year) matches lamp life and ensures only disinfected water is delivered.

Durable UV resistant cover allows for flexible, vandal resistant, exterior installation.

RainBan®k MKII controller option

• Provides seamless automatic mains water back-up and source indication

• Automatically reverts to mains water if power fails or pump is removed

Torrium®2 TT70 controller option

• Intelligent automatic pump control maximises pump efficiency by adjusting run on time and cut in pressures

High efficiency Steriflo UV disinfection system with low pressure lamp and test tube quartz sleeve for easy cleaning and high performance.

20 micron Filterpure pre-filtration for long cleaning intervals with dirt, rust, sediment and debris reduction.

1 micron Filterpure filtration for parasitic cyst reduction and further sediment reduction to reduce ‘shadowing’ of bacteria and viruses.

*Cannot treat water contaminated by metals, chemicals, algal toxins or radiation

Roof Tank Pump Valve Coarse Filtration

Fine Filtration

UVDisinfection

Valve

1 2 3

microlene.com.au | microlene.co.nzThis literature is not a complete guide to product usage. All images provided in this document are for illustration purposes only. Further information is available from your Davey Dealer, Davey Support Centre and from the relevant product Installation and Operating Instructions. Must be read in conjunction with the relevant product Installation and Operating Instructions and all applicable statutory requirements. Product specifications may change without notice. ® Davey and Microlene are registered trademarks of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2017.

Microlene Aquashield UV System

Operating Limits

Capacities to 70 lpm

Maximum system pressure 700 kPa

Max. Mains water pressure for RB models 850 kPa

Water temperature range 8oC – 40oC

Maximum ambient temperature 50oC

Lamp life 9,000 hrs (1 year)

Identification Of The System

AS HM 60 08 RB

Pump controller

Output kW (P2) x 10

Flow @ BEP (lpm)

Pump code

AS = Aquashield® pre�x

RB = RainBank®

T = Torrium®

HM = HM SeriesHS = HS Series

Identification Of The System

Use a rope to position and retrieve the pump. Do not lower or retrieve the pump using the power lead as this may damage the cable entry seals, causing water leaks and unsafe operation.

Don’t use this product for recirculating or filtering swimming pools, spas, etc. While these pumps are built to high safety standards, they are not approved for installations where people will be in the water while they are operating.

Don’t pump abrasive materials. Sand and grit in the water being pumped will accelerate wear, causing shortened pump life.

Keep your pump clean, particularly in situations where lint, hair or fibrous materials may get bound around the pump shaft. Regular inspection and cleaning will extend pump life.

Make room for the float switch to operate. Automatic models have a float switch to turn them on when the water level rises and turn them off again when it has been pumped down to the safe operating level of the pump. If the float switch is not free to rise and fall, correct pump operation may not be possible.

Don’t run your pump dry. Non-automatic models must be switched off manually or by way of an external float/level switch when the water level is reduced to the top of the pump housing.

Replacement Parts

Code Description

GPH550N2/W Steriflo Lamp

TT600 Steriflo Quartz Sleeve

S24X3N70 Steriflo Oring

20PP20J 20 micron pleated filter

1PS20J 1 micron spun filter

Service Intervals**

20 micron filter Clean Replace

3 months up to 12 months

1 micron filter Replace up to 12 months

UV lamp Replace 12 months

UV Quartz Sleeve Clean 3-6 months

**Will vary depending on water quality. Check pressure drop ‘Gauge Set’. Based on clean rainwater.

Materials Of Construction

Part Material

Housing

Cover Polyethylene

Frame 304 stainless steel

Surface pumps

Pump casing 304 stainless steel

Pump backplate 304 stainless steel

Pump stages HM HS

304 stainless steelGlass filled noryl

Pump impellers HM HS

304 stainless steelGlass filled polycarbonate

Pump shaft HM HS

316L stainless steel303 stainless steel

Neck rings HM HS

TeflonPolypropylene & teflon

Mechanical seal Carbon / ceramic

O-rings HM HS

EPDMNitrile rubber

Motor shell & lantern bracketMarine grade aluminium with baked polyester powder coat

Submersible pumps

Impeller Glass filled polycarbonate

Lock nut 304 stainless steel

Pump casing Glass filled polycarbonate

Diffuser and blanking ring Glass filled noryl

Mechanical seal – pump Carbon / ceramic

Mechanical seal – motor Silicon carbide / ceramic in oil bath

Shaft seal elastomer Nitrile rubber

Pump shaft 304 stainless steel

O-rings Nitrile rubber

Motor shell 304 stainless steel

Bottom bearing housing Cast 316 stainless steel

Upper motor cover Cast 316 stainless steel

Handle 304 stainless steel

Fasteners 304 stainless steel

Float & power supply leads HO7RN-F oil resistant

Controller - Torrium2

Housing Glass reinforced nylon

Diaphragm Santoprene 87

Springs Molybond coated tempered steel

Sensor plate 316 stainless steel

Inlet union Glass reinforced nylon

Orings Nitrile

Controller - RainBank

Housing Glass reinforced nylon

Diaphragm Santoprene 87

Springs D.R Brass

Sensor plate 316 stainless steel

Filters

Filter housing Glass reinforced polypropylene

20 micron filter Pleated polyester fabric

1 micron filter Spun melt polypropylene fabric

Steriflo UV disinfection unit

Chamber 304 stainless steel

Lamp Low pressure high intensity

Sleeve Quartz

Pipework

Braided hose Silicone lined stainless steel

microlene.com.au | microlene.co.nzThis literature is not a complete guide to product usage. All images provided in this document are for illustration purposes only. Further information is available from your Davey Dealer, Davey Support Centre and from the relevant product Installation and Operating Instructions. Must be read in conjunction with the relevant product Installation and Operating Instructions and all applicable statutory requirements. Product specifications may change without notice. ® Davey and Microlene are registered trademarks of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2017.

Microlene Aquashield UV System

Hydraulic Performance

Note: Do not flow water over 70 lpm.

800

700

600

500

400

300

200

100

00 10 20 30 40 50 60 70

HS60-08T/RB

D42A/B

D53A/B

HM60-10T/RB

FLOW (lpm)

PRESSURE (kPa)

microlene.com.au | microlene.co.nzThis literature is not a complete guide to product usage. All images provided in this document are for illustration purposes only. Further information is available from your Davey Dealer, Davey Support Centre and from the relevant product Installation and Operating Instructions. Must be read in conjunction with the relevant product Installation and Operating Instructions and all applicable statutory requirements. Product specifications may change without notice. ® Davey and Microlene are registered trademarks of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2017.

DW

P0

25

4-4

/07

17

Microlene Aquashield UV System

Dimensions (mm) – Aquashield MAX

Dimensions (mm) – Submersible Pump

A F

G45

116

B

C

D

DE

MainsWater In(RB only)

Power In PotableWater Out

RainwaterInlet

Model A B C D E F G Inlet Outlet Weight (kg)

ASHS60-08T 905 960 597 226 305 279 158 32 25 92

ASHS60-10RB 905 960 597 226 305 279 158 32 25 96

Model A B C D E F Outlet B.S.P. Weight (kg)

D45A/B 475 130 370 235 195 330 1"F 18.5

D53A/B 535 170 430 235 195 330 1"F 19.5