VASCOCATH® The Generation of Steerable Catheters Hartmut Görtz, Dr. med. Lingen Jörg Teßarek, Dr. med. Münster Hansgeorg Schaaf, Dipl-Ing. Pfaffenhofen VASCOCATH is a registered trademark of POLYDIAGNOST GmbH

V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Embed Size (px)

Citation preview

Page 1: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

VASCOCATH®The Generation of Steerable Catheters

Hartmut Görtz, Dr. med. LingenJörg Teßarek, Dr. med. MünsterHansgeorg Schaaf, Dipl-Ing. Pfaffenhofen

VASCOCATH is a registered trademark of POLYDIAGNOST GmbH

Page 2: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

VASCOCATH® The Generation of Steerable Catheters

Target

• Reach any desired target within the vascular system

• Few catheter changes• As atraumatical as possible

Page 3: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Target

• Simple application• Minimizes:

- time resources- material resources

VASCOCATH® The Generation of Steerable Catheters

Page 4: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Endovascular in situ bypass

1999

Re-sterilisable, steerable 8F AngioscopePOLYSCOPE-VASCOCATH

VASCOCATH is a registered Trademark of POLYDIAGNOST GmbH

The Path of Development

VASCOCATH® The Generation of Steerable Catheters

Page 5: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

1999

VASCOCATH® The Generation of Steerable Catheters

Endovascular in situ bypass

Re-sterilisable, steerable 8F AngioscopePOLYSCOPE-VASCOCATH

Page 6: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Modular 8F endoscope with sterile modular catheter

POLYSCOPE

2006POLYSCOPE

VASCOCATH® The Generation of Steerable Catheters

Page 7: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Example of vascular endoscopy with stent surveillance

(movie)

POLYSCOPE VASCOCATH

(Source: Priv. Doz. Dr. Hartmut Rimpler, Vivantes Klinikum Friedrichshain, Berlin)

VASCOCATH® The Generation of Steerable Catheters

Page 8: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

2007

Steerable 8F catheter-VASCOCATH®

1. working channel 0.035 ´´ 1.2 mm2. working channel 0.020 ´´ 0.63 mm

VASCOCATH® The Generation of Steerable Catheters

Page 9: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

90 degrees bent

VASCOCATH® The Generation of Steerable Catheters

Page 10: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

180 degrees bent

VASCOCATH® The Generation of Steerable Catheters

Page 11: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

225 degrees bent

VASCOCATH® The Generation of Steerable Catheters

Page 12: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

180 degrees bent with 0.035´´ guiding wire

VASCOCATH® The Generation of Steerable Catheters

Page 13: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Renal artery stenosis - VASCOCATH® 8F

VASCOCATH® The Generation of Steerable Catheters

Page 14: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

VASCOCATH® The Generation of Steerable Catheters

Renal artery stenosis - VASCOCATH® 8F(movie)

Page 15: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Stenosis of the superior mesenteric artery - VASCOCATH® 8F(movie)

VASCOCATH® The Generation of Steerable Catheters

Page 16: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Inferior mesenteric artery - VASCOCATH® 8F(movie)

VASCOCATH® The Generation of Steerable Catheters

Page 17: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Probing of the renal artery with fenestrated Endograft - VASCOCATH® 8F(movie)

VASCOCATH® The Generation of Steerable Catheters

Page 18: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Aneurysm of superior mesenteric artery - VASCOCATH® 8F(movie)

VASCOCATH® The Generation of Steerable Catheters

Page 19: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

VASCOCATH® - 5,5 F 2 working channels 0,020´´ 0,55 mm

VASCOCATH® The Generation of Steerable Catheters

Page 20: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Cross-over-maneuver - VASCOCATH® 5,5F(movie)

VASCOCATH® The Generation of Steerable Catheters

Page 21: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Summary

• Innovative system of steerable catheters

• Saves time and material

• Extends endovascular spectrum

VASCOCATH® The Generation of Steerable Catheters

Page 22: V ASCO C ATH ® The Generation of Steerable Catheters Hartmut Görtz, Dr. med.Lingen Jörg Teßarek, Dr. med.Münster Hansgeorg Schaaf, Dipl-Ing.Pfaffenhofen

Summary

Being developed:

• Steerable sheath 9,5F• Smaller catheter diameters 5,5F• Balloon arming• Different bending radiuses• Different degrees of rigidity