Vanguard Tibial Bearings Vanguard Tibial Bearings are available in ArCom ® Direct Compression Molded (DCM) Polyethylene and E1 Antioxidant Infused Technology. ArCom Polyethylene is clinically proven to be resistant to wear, delamination, and oxidation 1–4 E1 Antioxidant Infused Bearings, founded on ArCom heritage, are infused with Vitamin-E, a natural antioxidant. E1 Technology defines a new class of tibial bearings and overcomes the limitations of remelted and annealed polyethylenes by uniting true oxidative stability, high mechanical strength, and ultra-low wear. 5,6 References 1. Beading, L. Direct Molded Components Shown to Resist Oxidation. Orthopedics Today. 17(4): 1997. 2. Furman, B. et al. (Abstract) Effect of Resin Type and Manufacturing Method on UHMWPE Oxidation and Quality at Long Aging and Implant Times. 43rd Annual Meeting Orthopaedic Research Society, San Francisco, CA, February 9–13, 1997. 3. Beading, L. Polyethylene-Related Failure: A Challenge to TKA. Orthopedics Today. 16–21, 1996. 4. Ritter, M. et al. Long-Term Survival Analysis of a Posterior Cruciate- Retaining Total Condylar Total Knee Arthroplasty. Clinical Orthopaedics and Related Research. 309:136–145, 1994. 5. Data on file at Biomet. Bench test results not necessarily indicative of clinical performance. 6. Kurtz, S. et al. The UHMWPE Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement. Elsevier Academic Press. San Diego, CA. 2004. 7. Parks, N. et al. Modular Tibial Insert Micromotion. Clinical Orthopaedics and Related Research. 356:10–15, 1998. 8. Sosa, M. et al. Micromotion Between the Tibial Tray and the Polyethylene Insert. Fifth World Biomaterial Congress. Toronto Canada, May 29–June 2, 1996. 9. Incavo, S. et al. Tibial Plateau Coverage in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research. 299:81–85, 1994. All trademarks herein are the property of Zimmer Biomet or its subsidiaries unless otherwise indicated. This material is intended for the sole use and benefit of the Zimmer Biomet sales force and physicians. It is not to be redistributed, duplicated or disclosed without the express written consent of Zimmer Biomet. For product information, including indications, contraindications, warnings, precautions and potential adverse effects, see the package insert and Zimmer Biomet’s website. ©2016 Zimmer Biomet BIO0264.2-REV0616 Authorized Representative Biomet UK Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA UK Legal Manufacturer Biomet Orthopedics P.O. Box 587 56 E. Bell Drive Warsaw, Indiana 46581-0587 USA zimmerbiomet.com CE mark on a surgical technique is not valid unless there is a CE mark on the product label. 0086 DCM UHMWPE Volumetric Wear Rate (mm 3 /MC) Volumetric Wear Rates of Largest Cruciate Retaining (CR) Tibial Bearing Profile 1 Tested at Biomet Biomaterials Laboratory 86% CR wear reduction over Direct Compression Molded E1 Material 0 10 20 30 40 50 43.4 6.1 Cruciate Retaining 3 degrees posterior slope 15 degrees internal/external rotation Cruciate Retaining Lipped Enhanced posterior lip 15 degrees internal/external rotation Anterior Stabilized Prominent 10 mm anterior lip 5 mm posterior lip 6 degrees internal/external rotation Vanguard ® Cruciate Retaining Knee Brochure

Vanguard Cruciate - Zimmer Biomet · 2020-01-10 · Beading, L. Direct Molded Components Shown to Resist Oxidation. Orthopedics Today. 17(4): 1997. 2. Furman, B. et al. (Abstract)

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Vanguard Cruciate - Zimmer Biomet · 2020-01-10 · Beading, L. Direct Molded Components Shown to Resist Oxidation. Orthopedics Today. 17(4): 1997. 2. Furman, B. et al. (Abstract)

Vanguard Tibial BearingsVanguard Tibial Bearings are available in ArCom® Direct Compression Molded (DCM) Polyethylene and E1™ Antioxidant Infused Technology. ArCom Polyethylene is clinically proven to be resistant to wear, delamination, and oxidation1–4

E1 Antioxidant Infused Bearings, founded on ArCom heritage, are infused with Vitamin-E, a natural antioxidant. E1 Technology defines a new class of tibial bearings and overcomes the limitations of remelted and annealed polyethylenes by uniting true oxidative stability, high mechanical strength, and ultra-low wear.5,6

References

1. Beading, L. Direct Molded Components Shown to Resist Oxidation. Orthopedics Today. 17(4): 1997.

2. Furman, B. et al. (Abstract) Effect of Resin Type and Manufacturing Method on UHMWPE Oxidation and Quality at Long Aging and Implant Times. 43rd Annual Meeting Orthopaedic Research Society, San Francisco, CA, February 9–13, 1997.

3. Beading, L. Polyethylene-Related Failure: A Challenge to TKA. Orthopedics Today. 16–21, 1996.

4. Ritter, M. et al. Long-Term Survival Analysis of a Posterior Cruciate-Retaining Total Condylar Total Knee Arthroplasty. Clinical Orthopaedics and Related Research. 309:136–145, 1994.

5. Data on file at Biomet. Bench test results not necessarily indicative of clinical performance.

6. Kurtz, S. et al. The UHMWPE Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement. Elsevier Academic Press. San Diego, CA. 2004.

7. Parks, N. et al. Modular Tibial Insert Micromotion. Clinical Orthopaedics and Related Research. 356:10–15, 1998.

8. Sosa, M. et al. Micromotion Between the Tibial Tray and the Polyethylene Insert. Fifth World Biomaterial Congress. Toronto Canada, May 29–June 2, 1996.

9. Incavo, S. et al. Tibial Plateau Coverage in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research. 299:81–85, 1994.

All trademarks herein are the property of Zimmer Biomet or its subsidiaries unless otherwise indicated.

This material is intended for the sole use and benefit of the Zimmer Biomet sales force and physicians. It is not to be redistributed, duplicated or disclosed without the express written consent of Zimmer Biomet.

For product information, including indications, contraindications, warnings, precautions and potential adverse effects, see the package insert and Zimmer Biomet’s website.

©2016 Zimmer Biomet

BIO0264.2-REV0616

Authorized RepresentativeBiomet UK Ltd.Waterton Industrial EstateBridgend, South WalesCF31 3XA UK

Legal ManufacturerBiomet Orthopedics P.O. Box 58756 E. Bell DriveWarsaw, Indiana 46581-0587 USA

zimmerbiomet.com

CE mark on a surgical technique is not valid unless there is a CE mark on the product label.

0086

DCMUHMWPE

Vo

lum

etri

c W

ear

Rat

e (m

m3 /M

C)

Volumetric Wear Rates of Largest Cruciate Retaining (CR)

Tibial Bearing Profile1

Tested at Biomet Biomaterials Laboratory

86% CR wear reduction

over Direct Compression

Molded

E1™ Material

0

10

20

30

40

50

43.4

6.1

Cruciate Retaining

• 3 degrees posterior slope

• 15 degrees internal/external rotation

Cruciate Retaining Lipped

• Enhanced posterior lip

• 15 degrees internal/external rotation

Anterior Stabilized

• Prominent 10 mm anterior lip

• 5 mm posterior lip

• 6 degrees internal/external rotation

Vanguard® CruciateRetaining Knee

Brochure

Page 2: Vanguard Cruciate - Zimmer Biomet · 2020-01-10 · Beading, L. Direct Molded Components Shown to Resist Oxidation. Orthopedics Today. 17(4): 1997. 2. Furman, B. et al. (Abstract)

Vanguard Cruciate Retaining Knee | BrochureZimmer Biomet Tibial TrayThe Vanguard Complete Knee System features a symmetrical tibial tray design for optimal coverage, ArCom and E1 Tibial Bearings for proven wear resistance,1–4 and a proven locking mechanism shown to be “the most stable overall.”7,8 Zimmer Biomet Tibial Trays are available with Interlok Finish for cemented applications or Regenerex Porous Titanium Construct to enhance bone fixation in cementless applications.

0–15°

Softened Anterior FlangeStreamlined design to

help avoid incidence of “retinacular tenting”

Deep Trochlear GrooveReduces patellar forces

throughout range of motion

Proportional Posterior Condyles

Allows for optimal contact area in deep flexion

Wide Proximal Trochlear GrooveProvides excellent patellar tracking regardless

of patient’s Q-angle*

Optimized Tibiofemoral Articulation

Increased contact area in high flexion and axial rotation

Extended Trochlear GrooveAllows the patella to maintain full contact with the femoral component in deep flexion

Additional Features of the Vanguard CR Design: • 10 femoral components that grow anterior/posterior on average

by 2.4 mm increments

• Fully interchangeable tibial/femoral sizing

• 1:1 tibial/femoral coronal congruency

• PPS® Porous Plasma Spray Coating for cementless or Interlok® Finish for cemented applications

*within 0–15 degrees of Q-angle

Removable LugsFor modular

augmentation

Independent Augments

CR component can accept posterior or distal femoral augments

Interchangeable Bearing Options

CR, CR Lipped, and AS bearings can be utilized

with the CR femur

Rotated Bearing Surface Articulation

Increases contact area by 13 percent1

Proven Compressive Locking Mechanism

Clinically proven to minimize micromotion

and backside wear5

Tibial Tray DesignSymmetric tibial tray available in nine sizes

for optimal tibial coverage6

Patellar Tendon Relief

Facilitates increased range of motion

Raised Anterior LipProvides enhanced femoral

rotational stability and controls anterior femoral slide

The Vanguard Knee System offers surgical simplicity with complete component interchangeability.