4
IE2 motors for use on a frequency converter www.vem-group.com Variable-speed drives

Variable-speed drives · 2015. 5. 18. · Variable speed drives for a broad range of applications Standard insulation For motors with standard insulation, the permissible peak voltages

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • IE2 motors for use on a

    frequency converter

    www.vem-group.com

    Variable-speed drives

    www.vem-group.com

  • IE2

    mot

    ors

    for

    use

    on a

    freq

    uenc

    y co

    nver

    ter

    IE2 motors for use on a frequency converterVariable speed drives for a broad range of applications

    Standard insulation For motors with standard insulation, the permissible peak voltages at the connecting terminals must not exceed the limit curve shown in Fig. 7 of DIN VDE 0530-17:2007-12 (IEC/TS 60034-17:2006). If the permissible peak voltage is not observed, it is either necessary to provide a filter at the converter output or use a motor with enhanced insulation.

    Enhanced winding insulation Operation on a frequency converterup to 500 V without filter

    Motors of the design series IE2-WU.. possess enhanc-ed winding insulation to permit operation of the motor on frequency converters for mains voltages up to 500 V without filter. From IEC size 315, insulated bearings are used on the non-drive side as standard, and the insu-lation of the PTC thermistors is adapted to the higher withstand voltage of the winding.

    Subject to limitation of the impulse voltages to the cor-responding maximum permissible values, motors of the design series IE2-WU.. are also well suited for operation on 690 V converters.

    Sizes 80 to 400Power range 0.75 – 355 kW (Outputs for size 400 by request)Efficiency class IE2 acc. to IEC/EN 60034-30, valid for mains operation and continuous duty S1 Type of protection IP 55 acc. to IEC/EN 60034-5, higher types of protection as optionType of construction IM B3, IM B35, IM B5, IM B14, IM B34 and derived types acc. to IEC/EN 60034-7Duty type S1/S8, S1/S9 acc. to IEC/EN 60034-1Type of cooling IC 411 (K..R) or IC 416 (K..F) acc. to IEC/EN 60034-6

    Series IE2-WU.. for operation on a 500 V converter without filter

  • Please refer to our catalogues for technical details. The catalogues are available in printed or in digital version on DVD. They are also available in the internet.

    IE2

    mot

    ors

    for

    use

    on a

    freq

    uenc

    y co

    nver

    ter

    Size Rated output P (kW) Series IE2-WU.. Types of cooling IC 411 and IC 416, without filter up to 500 V 2-pole 4-pole 6-pole 8-pole* 3000 1500 1000 750 rpm80 K 0.75 - - -80 G 1.1 0.75 - -90 S 1.5 1.1 0.75 -90 L 2.2 1.5 1.1 -100 L 3 2.2 - 0.75100 LX - 3 1.5 1.1112 M. 4 4 2.2 1.5132 S.T 5.5 - - -132 S 5.5 5.5 3 2.2132 SX 7.5 - - -132 M - 7.5 4 3132 MX - - 5.5 -160 M 11 11 7.5 4160 MX 15 - 5.5160 L 18.5 15 11 7.5180 M 22 18.5 - -180 L - 22 15 11200 L 25 30 18.5 15200 LX 37 - 22 -225 S - 37 - 18.5225 M 45 45 30 22250 M 55 55 37 30280 S 74 75 45 37280 M 87 90 55 45315 S 110 110 75 55315 M 132 132 90 75315 MX 160 160 110 90315 MY 192 200 132 110315 L 220 250 160 132315 LX 270 285 185 145355 MY 315 315 200 160355 M 330 355 250 200355 MX - - 300 215355 LY - - 315 230

    Outputs for size 400 by request

    * without IE-marking

    IE2 motors are suitable for the most varied applications also in converter-fed operation.

  • www.vem-group.com

    © 2015 KOMMUNIKATION SCHNELL GmbH

    VEM/05-015.2 E/0315 Printed in Germany. Subject to change.

    For detailed information please visit our website.

    VEM Holding GmbH

    Pirnaer Landstraße 176 D-01257 Dresden

    Phone: +49 351 208-0 Fax: +49 351 208-1028

    VEM Sales

    Low voltage

    Phone: +49 3943 68-0 E-Mail: [email protected]

    High voltage

    Phone: +49 351 208-0 E-Mail: [email protected]

    Drive systems

    Phone: +49 30 9861-2104 E-Mail: [email protected]