490-GC: The “Go Anywhere” Micro-GC
2
What is the 490-GC
• The 490-GC is Varian’s 5th generation of the Micro-GC series
• Small, fast and rugged gas analyser
• Based on advanced micro-machining technology
• Instrument control and data handling by Galaxie
• Usage in laboratory, on-line, at-line and for field applications
3
Why the 490-GC
• Immediate answers for gas and vapour samples• Fast analysis, separations in seconds• Analyse anywhere, in the lab, at-line, on-line, in the field• Easy to use, no need for specialised trained personnel• Consuming less bench space• Local or remote control• Complete software and user-programs• Savings on gas cylinder purchases and gas related
items• Savings on installation time
4
What is a 490-GC
The 490-GC is• Multi Method• Multi Stream
–Micro GC- Controlled by and reporting by Galaxie data
handling package- High Speed Gas analysis
5
490-GC Dual and Quad version
490-GC Dual cabinet 490-GC Quad cabinet
6
How does the 490-GC Micro-GC Work
7
490-GC Micro-Machined Technology
CHIPINJECTOR
GCCOLUMN MICRO TCDMICRO EGC
8
How does the 490-GC Micro-GC Work
Complete miniaturised GC system:• 1 up to 4 complete GC channels
Each GC channel is a separate GC:• Silicon micro-machined injector• Oven with analytical column • Micro-machined Thermal Conductivity Detector (µ-TCD)• Pneumatics• Electronics
Each channel is tuned for a specific part of the sample
9
Permanent Gases
Peak identification1 Hydrogen2 Oxygen3 Nitrogen4 Methane5 Carbon Monoxide
CP-Molsieve 5Å Temperature : 80°CCarrier gas : Argon
10
Light Hydrocarbons
Peak identification1 Carbon Dioxide2 Ethylene3 Ethane4 Acetylene5 Hydrogen Sulfide
CP-Pora PLOT-U Temperature : 90°CCarrier gas : Helium
11
Extended Hydrocarbons
Peak identification1. iso-Pentane2. normal-Pentane3. Hexane4. iso-Octane
CP-Sil 5 CBTemperature : 80°CCarrier gas : Helium
12
490-GC Communication
Various communication protocols
• Standard Ethernet TCP/IP
• Six analogue input signals(external process signals)
• Optional two extra Com Ports for external devices
• Selectable RS-232 or RS-485
13
490-GC
Galaxie Data System
IntegrationCalculation
Control
Signal
Report
• Instrument Control• Data Acquisition• Report Generation
Galaxie™ Chromatography Software
14
490-GC PRO VersionA Fast, Small Form Factor, High
Performance Gas Measurement Platform Designed for Unattended Operation and
supports Industrial networks
15
490-GCPC Data System
Control
Signal
Set up / Operation
Report
490-GC Standard versus 490-GC PRO
PCPROstation 490-GC PRO
Maintenance
490-GC PROPC PROstation
CommunicationResult Industrial
networks
16
490-GC PRO Objective
Product differentiation• Process Environment• On-line / at-line
Benefits• Implement proven Lab Technology
in Process Analytics • Instrument-hardware availability for autonomous
operation• Communicates results instead of raw/signal data
17
What is a 490-GC PRO
The 490-GC PRO isSingle Method
AutonomousMulti Sample Stream
High Speed Gas analysisAnalyser / Monitor (Micro-GC)
Communicator of Results
18
490-GC PRO
OBDH
Local display(optional)
Automation
Application
External I/Odevices
Modbus
FTP client
PROstation
19
On Board Data Handling
Built into the 490-PRO:• Peak integration• Peak identification• Peak calibration• Peak grouping
This means that for routine measurements:• Full autonomous operation (no operator required)• No external data handling software required • No PC needed to generate results
20
490-PRO – Fully Automated Operation
Sequential measurement runs that include:• sample type • valve/sample position• flush time• calibration level
Calibration and/or verification analysis• after a desired # of samples • based on a specific time• on demand via remote command• automatic (re)calibration if verification values “fail”
21
490-PRO – Fully Automated Operation
Stream selection and control:• Electrically actuated multi-position valves • Solenoids based stream selectors
Remote Communication:• MODBUS • Digital input
22
Standard Functionality
• Validation of• Verification samples• Sample streams• Calibration samples
• Calculation parameters:• Multi channel normalisation. Optional a bridge component• Add estimated concentrations for non detected peaks• Convert acquired analog input signals to functional values, ex.
sample flow• Definable alarms to:
– activate a relay – store results in MODBUS registers
• Definable 4-20 mA signals
23
Additional available Functionality in 490-PRO
“Energy meter”• According to ISO 6976, ASTM D3588, GPA 2172 and GOST
– calorific value– relative density – compressibility factor
35 day logging:• according API (chapter21)
Serial output:• MODBUS communication
Note: requires licenses
24
MODBUS (490-PRO is a MODBUS “slave”):
Communication:• Serial: RS-232 or RS-485• Ethernet TCP/IP
Commands from Industrial Network:• Start analysis type
– Run, calibration, verification, column conditioning, method parameters
• Stream selectionInformation to Industrial Network:
• Instrument status • OBDH results• Application results
Highly Flexible Communication & I/O
RS-232 or RS-485
Ethernet TCP/IP
25
490-GC PRO Connectivity
26
490-GC PRO Customer Responsibilities
Sample inlet tubing and
Sample conditioning
I/O Cable Connections
Display Fitting/MountingDCS Connections
&Programming
27
PRO Station Software
OBDH settings• Integration• Identification• Calibration settings
“Automation” settings • sequence• verification • calibration
Instrument method setup • temperatures, • pressures, etc.
PRO Station
TCP/IP
28
Application method setup• alarms• validations• external I/Os• calorific constants• sample conditions, etc)• LCD display parameters
Displayed• Chromatogram• Integration parameters• Instrument Status• Results (obtained from OBDH of 490-PRO)• MODBUS register table setup
PRO Station Software
29
Sample / Application results can be communicated via
• ModBus (incl instrument status) via TCP/IPoptional via RS232
• Analog output 4-20mA, extension board• Digital I/O, alarms, extension board
• Text file FTP/Client Server, via TCP/IP• LCD display (incl instrument status), serial port
• Web browser (incl instrument status), TCP/IP
Information is available to the outside world in different formats
Results !!! Not chromatograms and reports
Output of Results
30
Software Options
• 35 Day Logging (API Chapter 21):– Analysis data – Averages, Minimums and maximums of analysis data – Calibration data – Alarms – Method parameter changes – Power On-Off events – Error chromatograms (one per stream) – Static data (ID calibration cylinder, site name, etc.)
• Includes “history log” (remote PC)• Standard HTML reports• Custom HTML reports
31
19” Rack mounting
• Dual channel Micro-GC• Options
– Stream selection valve– Micro-Gasifier– Extension boards– Genie membrane filter– LCD screen– Pressure sensors
32
Sample Stream Automation
• Multiple sample stream measurement is possible• Stream selection:
– Valco electrically actuated multi positional valve – serially connected to the 490-GC– Simultaneously control 3 X16 ports; 46 streams max
• Solenoid based stream selectors: – Via relay control
• Similar to the standard 490-GC
RS-232
33
User definable • Time based scrolling• Sample results• GC status• Error information
External device • up to 10 meter from instrument• user can choose where to mount it
Communication• RS-232
RS-232
LCD Display
34
External Hardware Options
Extension boards:• Stackable up to 8 boards with
• maximum 64 relays• maximum 25 analog outputs
– 4-20mA outputs, 0-1V• maximum 64 digital I/O
• mountable on DIN-rail
• This means:• Flexible and robust connections• Standardised connections
Basic board on DIN rail housing
Analog board
Digital board
35
WebServer
• Inside 490-PRO• Obtain status from anywhere
490-PRO System
36
Application overview
490-GC & 490-GC PRO Options
38
RTS (Retention Time Stability), option
• Molsieve Columns• Increased retention time due to moisture/CO2
• Al2O3 Columns• Retention time shift due to moisture
Solution• Molsieve trap integrated
• Remove Moisture and CO2
– Improved backflush for % level CO2
39
Achieving stable retention times.
Retention time decreases steadily
Almost immediate stable retention times
40
Permanent Gases in Natural Gas
Column: Hayesep, 0.4m
Temperature: 60°C
Carrier Gas: Helium, 140 kPa
41
Hydrocarbons in Natural Gas
Column: CP-Sil 5 CB, 4m
Temperature: 60°C
Carrier Gas: Helium, 135 kPa
42
Extended Hydrocarbon Analysis
Column: CP-Sil 5 CB, 8m
Temperature: 140°C
Carrier gas: 150 kPa, Helium
43
THT in natural gas
Column: CP-Sil 19 CB, 6m
Temperature: 90°C
Carrier Gas: Helium, 150 kPa
44
Permanent gases on CP-COX column
45
Biogas, composition (1)
46
Biogas Application
Composition primarily CH4, CO2, N2 and some H2, O2and CO
• Channel 1. Molsieve column– H2, O2, N2, CH4 and CO
• Channel 2. PoraPLOT U column– CO2 and H2S
47
Biogas, channel 1, permanent gases
Molsieve column, 80°C
Carrier gas: Ar, 150 kPa
Backflush of C2+, CO2, moisture
48
Biogas, Channel 2, C2, C3, H2S and CO2,
PoraPLOT U column, 100°C
Carrier gas: He, 100 kPa
Back flush of C4+
49
Biogas, Channel 3, C3+
CP-Sil 5 CB column, 60°C
Carrier gas: He, 150 kPa
50
Accessories
• Gasifier• Genie filter• Stream Selection Valve• Field case• 19” Rack Housing• Syringe Injection• Integrated sample conditioning
51
Micro-Gasifier Mounted on 490-GC
Power Supply
Vent Outlet
Sample In
Sample Flow Control
Vent Flow Control
Conditioned Transfer Line
52
Genie Membrane Filter
• Protects the analyzer from damage and contamination
• Fully inert membrane technology
• Proven and widely accepted filtering technique
• Removes liquids from gas samples
• Removes particles from gas samples
• No interference with sample composition
• Compliant for BTU calorific value applications
• Suitable for PPB, PPM and percentage level analysis
• Standard Swagelok™ connections
• High and low flow membranes
• Stainless Steel, Polypropylene and Kynar housing
• Standard Viton housing seal
• Easy connection with 490-GC
Genie Model 170
53
490-GC Dual and Quad Field Cases
490-GC dual field case
490-GC quad field case
54
490-GC Field case
A
E
C
B
D
C
B
E
D
F
A
A. canister pressure gauge
B. battery indicator
C. fill opening for canister
D. open/close valve canister
E. handle for easy slide out of
dock station
F. battery compartment
55
19” Rack Micro-GC
56
New Syringe Injection
57
Syringe Injection
• Unheated• Front inlet• Septum nut
• 1/8” sample inlet still available• Luer Lock
• Standard 1/16” inlet still available• Optional way Ball valve
• Sample selectable via Syringe option or standard inlet
58