16
VariAx Foot Locking Plate System • Trauma and Deformity Correction • Polyaxial Locking Technology • Comprehensive Calcaneal Fracture Plates

VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

  • Upload
    dohuong

  • View
    235

  • Download
    3

Embed Size (px)

Citation preview

Page 1: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

VariAx Foot LockingPlateSystem

• TraumaandDeformityCorrection• PolyaxialLockingTechnology• ComprehensiveCalcanealFracture

Plates

Page 2: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Introduction

The reconstruction and fixation of bones in the foot can now be accomplished by means of the patented SmartLock polyaxial locking mechanism. This powerful feature allows a surgeon to insert polyaxial locking or non-locking screws at variable angles with respect to the plate, so that they can be targeted to address the location and geometry of a given fracture or osteotomy.

Each plate can be configured with a combination of locking and/or non-locking screws which satisfy the intraoperative requirements of a particular case, without constraint or reliance on any pre-existing plate designs.

Page 3: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Features and Benefits

• CompletePlatingSystem Multiple indication based plate

designs are included in the VariAx Foot Locking Plate System, which are engineered to address specific foot trauma and deformity indications.

H-Plate

Rectangular Plate

Broad Straight Plate

T-Plate Curved Plate

L-Plate

Oblique T-Plate

3-D Plate

Calcaneus Mesh PlateCalcaneus Standard Plate

Page 4: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Features and Benefits

-15° +15°

3.5mm Locking

2.7mm Locking

3.5mm Non- Locking

2.7mm Non- Locking

• FullRangeof2.7mmand3.5mmLockingandNon-LockingScrews

Offers intraoperative solutions to cover a broad range of clinical indications.

• LowProfilePlateDesignandReducedScrewHeadProminence

Each plate is designed to minimize soft tissue irritation by having a low profile (1mm – 1.5mm thickness). Furthermore, the screws are designed to have minimal head prominence when fully inserted in a plate, which further reduces the risk of irritation.

• AnodizationTypeII Increases the strength of all VariAx

Foot Plates, and may reduce the incidence of tissue adherence.

• PatentedSmartLockPolyaxialLockingTechnology

Each screw is made of titanium alloy (Grade V), which is slightly harder than the plates, which are made from commercially pure titanium (Grade II). When a locking screw is used, the thread in the head of the harder screw reshapes the softer titanium used in the plate, thus creating a secure form-fitting geometry. This process results in a solid, locked connection between the head of the screw, and the plate.

• UniqueOne-StepLocking Achieved by simply inserting a

locking screw within the polyaxial locking range of ±15°, without the need for further steps.

Page 5: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Features and Benefits

• TwoDedicatedCalcanealPlateDesigns

The VariAx Foot Locking Plate System offers two distinct calcaneal plate designs, each incorporating a different design philosophy.

The mesh design provides surgeons with an extremely low profile plate (1mm thick) that can be easily contoured, and has many screw placement options.

The standard plate design provides surgeons with a strong plate that can easily be contoured to the superior surface of the calcaneus.

Page 6: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Features and Benefits

ovalcompressionhole

ovalcompressionhole

lip

lip

• EfficientT7orT10ScrewHeadDesign

All VariAx Foot Locking Plate System screws are designed with either a T7 head (for 2.7mm screws), or a T10 head (for 3.5mm screws). This screw head design encourages efficient force transmission from the screwdriver blade to the screw, and reduces the risk of screw head stripping.

• OvalCompressionHolesallowforCompressionandLockingin

One-Step Oval compression holes allow

for the active compression of different bone segments along the long axis of the oval hole. As a screw is inserted and tightened into an oval compression hole, compression can be achieved, and if a locking screw is used, the screw can then be locked into the plate in a single step.

Page 7: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Features and Benefits

• ModularInstrumentPlatform The modular instrumentation system

is designed for seamless integration within the Stryker Foot Solutions Portfolio.

• ColorCodingofInstruments The instruments are color coded to

facilitate ease-of-use during surgery.

• DeluxeorBasicConfigurations The VariAx Foot Locking Plate

System comes in two configurations: a Deluxe configuration, and a Basic configuration. The Deluxe configuration contains every implant design, while the Basic configuration consists of a reduced selection of implants, and provides a cost effective solution for foot surgery.

The SmartLock Locking Technology is patented (US 6,322,562; DE 43 43 117; EP 1 143 867) by Professor Dietmar Wolter, Hamburg, Germany.

Page 8: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Ordering Information

REF Description

Instruments

TwistDrills

QuantityperBasicSet

QuantityperDeluxeSet

0

optional

optional

optional

OptionalInstruments

45-27005

45-35005

45-27001

45-35001

45-80001

45-80005

45-27015

45-35015

45-85000

45-35030

45-27030

45-80010

45-80020

64-20129

45-80030

29-13462

Tap for 2.7mm Screws, AO, 50mm

Tap for 3.5mm Screws, AO, 70mm

Depth Measuring Gauge for 2.7mm Screws

Depth Measuring Gauge for 3.5mm Screws

Drill Guide for Circular Locking Holes

Drill Guide for Oval Compression Holes

Screwdriver Blade, AO, T7

Screwdriver Blade, AO, T10

Screwdriver Handle, Revolving/Rigid, AO

Holding Sleeve for 3.5mm screws

Holding Sleeve for 2.7mm screws

Plate Bending Pliers

K-Wire Cutting Pliers (max 1.6mm)

Forceps with Grasping Lips

Joint Distraction Forceps

Accessory Tray

1

1

1

1

1

1

2

2

2

1

1

2

1

1

1

1

1

1

1

1

2

2

2

1

1

2

1

1

45-27010

45-35010

Drill, 2.0mm x 102mm, WL50mm, AO-Shaft

Drill, 2.6mm x 122mm, WL70mm, AO-Shaft

2

2

2

2

Page 9: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

29-35000

29-13009

29-35200

29-31400

29-31007

29-31000

29-31021

29-31022

29-31004

29-31005

29-31006

29-31050

29-31052

29-31053

29-50000

Sterilization Container, 3 levels

Sterilization Container, 4 levels

Stryker Foot Container Lid - Half Size

VariAx Foot Instrument Tray

Drawer for Screw Racks

Deluxe Plate Module (includes Lid)

Inlay for Recon and Trauma Plates

Inlay for Calcaneus Plates

Screw Rack for 3.5 Locking Screws (includes Lid)

Screw Rack for 3.5 Bone Screws (includes Lid)

Screw Rack for 2.7 Screws (includes Lid)

Basic Plate Module (includes Lid)

Inlay 1 for Basic Plate Module

Inlay 2 for Basic Plate Module

Inlay Generic

REF Description

45-80000

29-31013

29-31012

29-31051

Spring for Holding Sleeve

Lid for Screw Rack

Lid for Deluxe Plate Module

Lid for Basic Plate Module

Miscellaneous

1

0

1

1

0

0

0

0

0

0

0

1

1

1

0

0

1

1

1

1

1

1

1

1

1

1

0

0

0

1

0

0

0

0

0

0

0

0

QuantityperBasicSet

QuantityperDeluxeSet

Ordering Information

ModulesAndTrays

Page 10: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Ordering Information

REF Description

40-35610

40-35612

40-35614

40-35616

40-35618

40-35620

40-35622

40-35624

40-35626

40-35628

40-35630

40-35632

40-35634

40-35636

40-35638

40-35640

40-35642

40-35644

40-35646

40-35648

40-35650

40-35655

40-35660

40-35665

40-35670

Locking Screw, T10, 3.5x10mm

Locking Screw, T10, 3.5x12mm

Locking Screw, T10, 3.5x14mm

Locking Screw, T10, 3.5x16mm

Locking Screw, T10, 3.5x18mm

Locking Screw, T10, 3.5x20mm

Locking Screw, T10, 3.5x22mm

Locking Screw, T10, 3.5x24mm

Locking Screw, T10, 3.5x26mm

Locking Screw, T10, 3.5x28mm

Locking Screw, T10, 3.5x30mm

Locking Screw, T10, 3.5x32mm

Locking Screw, T10, 3.5x34mm

Locking Screw, T10, 3.5x36mm

Locking Screw, T10, 3.5x38mm

Locking Screw, T10, 3.5x40mm

Locking Screw, T10, 3.5x42mm

Locking Screw, T10, 3.5x44mm

Locking Screw, T10, 3.5x46mm

Locking Screw, T10, 3.5x48mm

Locking Screw, T10, 3.5x50mm

Locking Screw, T10, 3.5x55mm

Locking Screw, T10, 3.5x60mm

Locking Screw, T10, 3.5x65mm

Locking Screw, T10, 3.5x70mm

�.�mm LOCKING SCREWS

5

5

5

5

5

5

5

5

5

5

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

QuantityperBasicSet

QuantityperDeluxeSet

REF Description

40-27608

40-27610

40-27612

40-27614

40-27616

40-27618

40-27620

40-27622

40-27624

40-27626

40-27628

40-27630

40-27632

40-27634

40-27636

40-27638

40-27640

40-27645

40-27650

Locking Screw, T7, 2.7x8mm

Locking Screw, T7, 2.7x10mm

Locking Screw, T7, 2.7x12mm

Locking Screw, T7, 2.7x14mm

Locking Screw, T7, 2.7x16mm

Locking Screw, T7, 2.7x18mm

Locking Screw, T7, 2.7x20mm

Locking Screw, T7, 2.7x22mm

Locking Screw, T7, 2.7x24mm

Locking Screw, T7, 2.7x26mm

Locking Screw, T7, 2.7x28mm

Locking Screw, T7, 2.7x30mm

Locking Screw, T7, 2.7x32mm

Locking Screw, T7, 2.7x34mm

Locking Screw, T7, 2.7x36mm

Locking Screw, T7, 2.7x38mm

Locking Screw, T7, 2.7x40mm

Locking Screw, T7, 2.7x45mm

Locking Screw, T7, 2.7x50mm

�.�mm LOCKING SCREWS

0

5

5

5

5

5

5

5

5

5

5

0

0

0

0

0

0

0

0

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

QuantityperBasicSet

QuantityperDeluxeSet

10

Page 11: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Ordering Information

REF Description

40-27008

40-27010

40-27012

40-27014

40-27016

40-27018

40-27020

40-27022

40-27024

40-27026

40-27028

40-27030

40-27032

40-27034

40-27036

40-27038

40-27040

40-27045

40-27050

Bone Screw, T7, 2.7x8mm

Bone Screw, T7, 2.7x10mm

Bone Screw, T7, 2.7x12mm

Bone Screw, T7, 2.7x14mm

Bone Screw, T7, 2.7x16mm

Bone Screw, T7, 2.7x18mm

Bone Screw, T7, 2.7x20mm

Bone Screw, T7, 2.7x22mm

Bone Screw, T7, 2.7x24mm

Bone Screw, T7, 2.7x26mm

Bone Screw, T7, 2.7x28mm

Bone Screw, T7, 2.7x30mm

Bone Screw, T7, 2.7x32mm

Bone Screw, T7, 2.7x34mm

Bone Screw, T7, 2.7x36mm

Bone Screw, T7, 2.7x38mm

Bone Screw, T7, 2.7x40mm

Bone Screw, T7, 2.7x45mm

Bone Screw, T7, 2.7x50mm

�.�mm NON-LOCKING SCREWS

0

3

3

3

3

3

3

3

3

3

3

0

0

0

0

0

0

0

0

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

QuantityperBasicSet

QuantityperDeluxeSet

REF Description

40-35010

40-35012

40-35014

40-35016

40-35018

40-35020

40-35022

40-35024

40-35026

40-35028

40-35030

40-35032

40-35034

40-35036

40-35038

40-35040

40-35042

40-35044

40-35046

40-35048

40-35050

40-35055

40-35060

40-35065

40-35070

Bone Screw, T10, 3.5x10mm

Bone Screw, T10, 3.5x12mm

Bone Screw, T10, 3.5x14mm

Bone Screw, T10, 3.5x16mm

Bone Screw, T10, 3.5x18mm

Bone Screw, T10, 3.5x20mm

Bone Screw, T10, 3.5x22mm

Bone Screw, T10, 3.5x24mm

Bone Screw, T10, 3.5x26mm

Bone Screw, T10, 3.5x28mm

Bone Screw, T10, 3.5x30mm

Bone Screw, T10, 3.5x32mm

Bone Screw, T10, 3.5x34mm

Bone Screw, T10, 3.5x36mm

Bone Screw, T10, 3.5x38mm

Bone Screw, T10, 3.5x40mm

Bone Screw, T10, 3.5x42mm

Bone Screw, T10, 3.5x44mm

Bone Screw, T10, 3.5x46mm

Bone Screw, T10, 3.5x48mm

Bone Screw, T10, 3.5x50mm

Bone Screw, T10, 3.5x55mm

Bone Screw, T10, 3.5x60mm

Bone Screw, T10, 3.5x65mm

Bone Screw, T10, 3.5x70mm

�.�mm NON-LOCKING SCREWS

3

3

3

3

3

3

3

3

3

3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

QuantityperBasicSet

QuantityperDeluxeSet

11

Page 12: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Ordering Information

REF Description

40-35900

40-27900

Washer for 3.5mm screw

Washer for 2.7mm screw

WASHERS QuantityperBasicSet

QuantityperDeluxeSet

0

0

10

10

REF Description

45-80100

45-80200

45-80300

K-Wire, Fully Threaded, 1.6mm x 200mm

K-Wire, Smooth, 1.4mm x 100mm

Steinmann Pin, Smooth, 2.5mm x 100mm

K-WIRES & STEINMANN PINS QuantityperBasicSet

QuantityperDeluxeSet

4

4

0

4

4

optional

1�

Page 13: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Ordering Information

40-15011

40-15012

40-15013

40-15014

40-15021

40-15022

40-15023

40-15031

40-15032

40-15033

40-15041

40-15042

40-15043

40-15061

40-15062

40-15071

40-15072

40-15081

40-15091

40-15092

40-10102

40-10104

40-10106

40-10112

40-10114

40-10116

Curved Plate, 4 holes

Curved Plate, 5 holes, Right

Curved Plate, 5 holes, Left

Curved Plate, 6 holes

H-Plate, Small

H-Plate, Medium

H-Plate, Large

Rectangular Compression Plate, size 1

Rectangular Locking Plate, size 2

Rectangular Compression Plate, size 2

Broad Straight Plate, Short

Broad Straight Plate, Medium

Broad Straight Plate, Long

3-D Plate, Left

3-D Plate, Right

Oblique T-Plate, Left

Oblique T-Plate, Right

T-Plate

L-Plate, Left

L-Plate, Right

Calcaneus Mesh Plate, Small

Calcaneus Mesh Plate, Medium

Calcaneus Mesh Plate, Large

Calcaneus Standard Plate, Small

Calcaneus Standard Plate, Medium

Calcaneus Standard Plate, Large

REF Description

Plates

2

2

2

2

0

0

0

0

0

2

0

0

0

2

2

2

2

0

2

2

0

0

0

0

0

0

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

QuantityperBasicSet

QuantityperDeluxeSet

1�

Page 14: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

1�

Complementary Products

AxSOS Distal Tibial Plates

T� Ankle Arthrodesis Nail

Asnis III Cannulated Screw System

Hydroset - Calcium Phosphate based Bone Substitute

Page 15: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

1�

Complementary Products

Hoffmann II Sterile Ankle Kit

Stryker Staple System

Numelock II Distal Tibia Plate

Page 16: VariAx Foot Locking Plate System - Strykerfoot.com · Features and Benefits oval compression hole oval compression hole lip lip • Efficient T7 or T10 Screw Head Design All VariAx

Biologics

Surgical Products

Neuro & ENT

Trauma, Extremities & Deformities

Biologics

Surgical Products

Neuro & ENT

Trauma, Extremities & Deformities

The information presented in this brochure is intended to demonstrate a Stryker product. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which products and techniques to use with their patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.

Stryker Corporation or its subsidiary owns the registered trademark: Stryker Stryker Corporation or its subsidiary owns, uses or has applied for the following trademarks: VariAx

Literature Number: 90-07804LOT A1807

Copyright © 2007 StrykerPrinted in Germany

Stryker Leibinger GmbH & Co. KGBötzinger Strasse 39-41D-79111 FreiburgGermany

www.osteosynthesis.stryker.com