    SITE ACCEPTANCE TEST

    III) Test of Automatic Laser Safety (ALS) Feature of optical Interface.

    Test Description:

    This test is performed to check the laser safety feature is functional in a node. When the laser safety

    feature is switched ON, in an event of optical receive signal failure the optical transmit signal is switched OFF thereby

    protecting the laser from undesirable operation.

    Test Equipment

    Power meter, Local Craft Terminal (LCT), Fiber optic patch cord

    Test Procedure:

    Connect the power meter on the STM optical unit by using optical patch cords and transmit the respectivelySTM signal.

    Using the LCT establish connection on the SDH node and monitor for any current alarms. Set the Automatic Laser Shutdown (ALS) to ON using the LCT software. Now, disconnect the receive optical path cord on the STM optical unit. This disconnection will be enable the ALS

    feature on the node.

    Record the result. Repeat the above procedure for other cards/Ports al

    Results:

    Slot-Port No. Optical Port Type

    (STM-1/4/16/64)

    Observation

    (Pass/Fail)

    Slot-Port No. Optical Port Type

    (STM-1/4/16/64)

    Observation

    (Pass/Fail)

    6325

    OPT TX

    LCT

    OPTICAL Power meter

  • 7/28/2019 vEERANAM

    3/3

    Automatic Laser Safety Test Status -----------------------(OK/Failed)