Ventilation Solutions Kitchens - Ventilation Solutions...Ventilation Solutions Kitchens. fantech 2 | Kitchens fantech Today’s kitchens have become much ... Models are available from

  • View
    216

  • Download
    4

Embed Size (px)

Text of Ventilation Solutions Kitchens - Ventilation Solutions...Ventilation Solutions Kitchens. fantech 2 |...

  • fantechVentilation SolutionsKitchens

  • fantech

    2 | Kitchens

    fantech

    Todays kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. Its the center of activity for the entire family as well as the ideal place to congregate for informal entertaining.

    Let Fantech show you how to keep the kitchen clear of smoke, grease, steam and odors with a ventilation system that works quietly and effectively.

    2 | Kitchens

  • fantech

    Kitchens | 3Kitchens | 3

  • fantech

    4 | Kitchens

    3

    26

    15

    4

    7

    How do I size my kitchen ventilation system?

    Wall Mount Installations: 100 CFM per foot of hood width

    Before choosing your kitchen ventilation fan, check with your local residential codes and the range manufacturers recommendations. If the range manufacturers recommendations are not available, use the information below to calculate the fan size. These recommendations follow the guidelines of the Home Ventilating Institute (HVI).

    Example: 36 (3 ft.) wide hood will require 300 CFM.

    Hood Width 3 CFM per Foot x 100 Air flow [CFM] 300

    Island Mount Installations: 150 CFM per foot of hood width

    Example: 36 (3 ft.) wide hood will require 450 CFM.

    Hood Width 3 CFM per Foot x 150 Air flow [CFM] 450

    When using a gas cooktop or range, it is recommended that the hood liner be 6 wider than the cooktop.

    4 | Kitchens

  • fantech

    Kitchens | 5

    9

    6

    1

    8

    fantech

    Makeup Air Solution

    1. Inline supply fan2. Filter cassette3. Shut-off damper 4. Intake wall hood5. Inline duct heater 1

    6. Silencer7. Fast clamps

    Kitchen Exhaust Solution

    1. Inline exhaust fan6. Silencer8. Roof cap 2

    9. Kitchen hood 3

    1 optional for cold climates2 supplied by others3 kitchen hood liners can support fans with total max amperage of 6 Amps

    Your makeup air solution should be simple, yet effective. Your Fantech makeup air system, along with your Fantech Inline Kitchen exhaust solution, will be quiet, comfortable and reliable.

    Under ideal conditions, even while preparing the largest and most demanding meals, your kitchen remains ventilated without pulling in air from every cracked window or crevice in your home.

    Every time an exhaust fan removes air fromyour home an equal volume of air must enter,this is called makeup air. Homes today arebuilt to tighter standards resisting infiltrationfrom outside air. With little to no leakage inthe building envelope, where does a powerfulrange hood get its makeup air? If the homedoes not have enough random air leaksaround the windows and doors, the makeupair is often pulled backwards from thechimney or water heater flue, this is calledbackdrafting. Since flue gasses from somecombustion appliance can include carbonmonoxide, backdrafting is dangerous and insome cases can be life threatening.

    Balanced ventilation makes your kitchen a dream

    Kitchens | 5

  • fantech

    6 | Kitchens

    Inline duct fans designed with airtight galvanized steel housings. Ideal for use with smaller, standard size ranges. Available in sizes from 303 CFM to 940 CFM. Duct sizes from 6 to 12.

    Speed-controllable Built-in thermal overload protection with automatic reset Can be installed in any position and outdoors Mounting bracket and hardware included

    Specification data

    RC Roof Capspage 11

    FG Series Inline Centrifugal Fans

    Model*Rated power

    Voltage / phase

    Maxamps

    RPM 0.0 Ps 0.1 Ps 0.2 Ps 0.4 Ps 0.6 Ps 0.8 Ps 1.0 Ps 1.5 Ps 2.0 Ps Max Ps Shippingweight

    UPC #

    W V / ~ A min-1 cfm in.wg lbs

    FG 6 72 120 / 1 0.68 2700 303 287 270 232 196 164 134 58 - 1.88 10 48060 8

    FG 6XL 153 120 / 1 1.48 2900 483 466 450 409 369 329 289 201 103 2.41 12 48065 3

    FG 8 119 120 / 1 1.14 2550 461 435 410 351 295 243 191 97 - 2.11 12 48080 6

    FG 8XL 142 120 / 1 1.45 2950 502 486 470 428 388 351 313 218 100 2.40 13 48085 1

    FG 10 138 120 / 1 1.43 3000 513 497 480 444 407 366 324 216 89 2.36 12 48100 1

    FG 10XL 196 120 / 1 1.96 3100 589 574 560 531 503 472 441 355 257 3.02 14 48105 6

    FG 12 181 120 / 1 1.87 2600 741 711 680 601 515 434 363 236 146 2.99 18 48120 9

    FG 12XL 301 120 / 1 3.01 2900 940 910 880 819 746 670 596 425 259 2.74 21 48125 4

    Performance shown is for installation type D - Ducted intlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the (accessories).* This product earned the ENERGY STAR by meeting strict efficiency guidelines. All models meets ENERGY STAR requirements.

    Fantech, Inc. certifies that the models shown herein are licensed to bear the AMCA Seal. The ratings are based on the tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).

    Air flow

    F

    A

    DE C

    3 3/4"

    2"

    Dimensions

    Duct connections are 1/8 smaller than duct size. Dimensional information is in inches.

    Model A C D E F

    FG 6 6 11 3/8 6 1/4 1

    7/8FG 6XL 6 13 1/8 7 1 1

    FG 8 8 13 1/4 6 1 1

    FG 8XL 6 13 1/4 6 1 1/8 1

    FG 10 10 13 1/4 4 3/4 1

    1/8 1

    FG 10XL 10 13 1/4 4 13/16 1

    1/4 1

    FG 12 12 16 6 11/16 1 1/4 1

    FG 12XL 12 16 6 11/16 1 1/2 1

    Accessories

    RSK Backdraft Damperpage 11

    FC Mounting Clampspage 11

    LDSilencerpage 11

    SHL/SGHL Hood Linerspage 10

  • fantech

    Kitchens | 7

    A C B

    DF G

    HE

    Powerful, smooth running mixed flow centrifugal fans designed for kitchen ventilation systems. Galvanized steel housings. The perfect size for use with commercial style ranges. Models from 836 CFM to 2016 CFM. Duct sizes from 8 to 12.

    High efficiency impeller generates low noise 100% speed-controllable Integral thermal contacts Can be installed in any position Airstream temperatures up to 140 F

    Dimensions

    Dimensional information is in inches.

    Model A B C D E F G H

    FKD 8XL 8 14 12 1/2 15 1/2

    3/4 2 3/8 6

    1/83/8

    FKD 10 10 14 12 1/2 15 1/2

    3/4 2 3/8 5

    3/8FKD 10XL 10 15 5/8 14 15

    3/4 2 3/8 6

    3/83/8

    FKD 12 12 15 5/8 14 12 1/2

    3/4 2 3/8 5

    1/83/8

    FKD SeriesInline Centrifugal Fans

    Fantech, Inc. certifies that the FKD Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

    Model

    Rated power

    Voltage / phase

    Maxamps

    RPM 0.0 Ps 0.25 Ps 0.50 Ps 0.75 Ps 1.0 Ps 1.5 Ps 2.0 Ps Max Ps Sones Shipping

    weightUPC #

    W V / ~ A min-1 cfm in.wg lbs

    FKD 8XL 327 120 / 1 2.991 2700 836 761 680 595 499 286 - 2.50 14.1 20 09085 2

    FKD 10 329 120 / 1 3.011 2700 910 836 752 653 547 342 - 2.60 15.3 19 09100 2

    FKD 10XL 529 120 / 1 4.481 2850 1266 1187 1100 1006 911 696 460 3.08 21.0 25 09105 7

    FKD 12 531 120 / 1 4.862 2900 1305 1228 1145 1054 948 712 479 3.08 23.0 24 09120 0

    Performance certified is for installation type D - Ducted inlet, Ducted outlet. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5ft. (1.5m) in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type D: ducted inlet hemisphericalfan sone levels. Ratings do not include the effect of duct end correction. All sone values shown are calculated at 0.5 (static pressure in inches W.G.)1Recommended speed control rating 5A 2Recommended speed control rating 10A

    Specification data

    Accessories

    RSK Backdraft Damperpage 11

    FC Mounting Clampspage 11

    LDSilencerpage 11

    SHL/SGHL Hood Linerspage 10

    RC Roof Capspage 11

  • fantech

    8 | Kitchens

    Exterior mounted exhaust fans can provide the perfect solution when space is at a minimum. Ideal for homes, condominiums and apartment complexes. Fans mount on an exterior wall. Models are available from 242 CFM to 435 CFM. Duct sizes - from 4 to 8.

    Wall mounted fan For high moisture, lint and dust laden air Excellent motor heat dissipation Permanently lubricated sealed ball bearings Ambient noise is kept outside

    Dimensions

    Dimensional information is in inches. Duct connections are 1/8 smaller than duct size.

    Accessories

    SHL/SGHL Hood Linerspage 10

    RVF 4XL Exterior-Mount Fan

    FC Mounting Clampspage 11

    Specification data

    Model

    Duct size Rated power

    Voltage / phase

    Max. amps

    0.0 Ps 0.1 Ps 0.2 Ps 0.4 Ps 0.6 Ps 0.8 Ps 1.0 Ps 1.5 Ps Shippingweight

    UPC #

    inch W V / ~ A cfm lbs

    RVF 6 6 92 120 / 1 0.84 242 220 204 177 150 123 68 - 10 23060 9

    RVF 6XL 6 149 120 / 1 1.46 381 360 346 315 285 258 213 64 14 23065 4

    RVF 8XL 8 151 120 / 1 1.42 435 410 392 348 312 282 235 102 14 23085 2

    Performance shown is for installation type with duct inlet Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG. RVF Series performance is sho