18
VERSION DESCRIPTION DOCUMENT Last modification: 2019-01-09 Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.6.3.0.0 (Patch 1..4) Date of print 2019/01/11 18 page(s) VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 1 of 18 Form I3D-VDD001 Release Date: 2018-06-11 General Advantages: PMI Display in Graphic View Extensions: Ability to retrieve and display PMI data from CATIA V5 CREO NX Surface Point / Shape deviation error o On manual probing in Teach and measure when the projection cannot be calculated, a message is diplayed allowing the user reporbing the point immediately to replace the wrong point or click ok to modify parameters o The same principle allows user reprobing last point when Shape deviation is greater than maximum shape deviation allowed

Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VERSION DESCRIPTION DOCUMENT

Last modification: 2019-01-09

Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.6.3.0.0 (Patch 1..4)

Date of print 2019/01/11 18 page(s)

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 1 of 18 Form I3D-VDD001

Release Date: ▪ 2018-06-11

General Advantages:

▪ PMI Display in Graphic View

Extensions:

• Ability to retrieve and display PMI data from CATIA V5 – CREO – NX

• Surface Point / Shape deviation error

o On manual probing in Teach and measure when the projection cannot be calculated, a message is diplayed allowing the user reporbing the point immediately to replace the wrong point or click ok to modify parameters

o The same principle allows user reprobing last point when Shape deviation is greater than maximum shape deviation allowed

Page 2: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 2 of 18 Form I3D-VDD001

• Toolmanager: Star probe tips deactivation

o Ability to deactivate one tip of star probe for a specific angle

o Advantage is ability to deactivate tips not used to save time during calibration and also deactive tips that cannot be calibrated on the sphere regarding their orientation.

o Deactivated tips are displayed in Orange in the grid

• Complex alignment RPS

o Ability to use Plane and Line (also Cylinder, Cone)

Page 3: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 3 of 18 Form I3D-VDD001

o Ability to Lock Translation and Rotation according to Coordinate System Axis in Complex alignment and optimization (access in yellow +)

o

• Tool analyzer

o Ability to check tool file loaded, allowing to verify probe validity according to calibration date, probe radius, deviation form

o

o

o Sorting by column in one click

o Customizing display able in parameter tabsheet

• Pantec Driver (option available in advanced parameters):

o Ability to force “Fast move buffer”

o Add an option to force “emergency mode” when closing inca3D

o Add an option to force “emergency mode” when execution is finished

o Add option to switch to emergency when machine doesnot move in MANUAL mode after 30s or N mn

Page 4: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 4 of 18 Form I3D-VDD001

• Angle calculation and displaying

o Ability to calculate constructed angles is several ranges [0°; +180°] [-180°; +180°] [0°; +360°]

• Ability to display angles as a

▪ Line: from Line1 to Line2 (former method) or

▪ Short Arc: Arc is displayed from Line 1 to Line 2 shortest way) or

▪ Long Arc: Arc is displayed from Line 1 to Line2 but may be greater than 180°

and turn counterclockwise ↺ (trigonometric) if user calculate angles in range

[0°;360°]

Page 5: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 5 of 18 Form I3D-VDD001

• New Graphical paremeters widnow

• Selecting CAD element in Local Coordinate system

o Add ability to select in which coodinate system are retrieved element clicked in on CAD file.

o In selection target pop-up menu, user can specify in which coordinate system will be sent elemnt clicked in graphic

Page 6: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 6 of 18 Form I3D-VDD001

o On the left-side list should be selected CAD coordinate system, on the right-side list user must choose “Nominal alignment” that will be applied to element clicked in the graphic

• Kren Arm

o When using a arm with 2 buttons: long click (leave down more than 1s) with 2nd button will DELETE last probed point

• Machine driver switch off

o Abilty to switch off machine driver in counter window.

o Allowing to keep Inca3D open with machine connection freed for another software (like support tool from hardware provider)

• Date in Report

o Ability to select short and long date in report keyword (2 options Short or Long date and 2 options with or without time)

o Available for any Date keyword and display according to Windows parameters ▪ mercredi 19 septembre 2018 09:55:25 ▪ 2018/09/19 09:55:25 ▪ mercredi 19 septembre 2018 ▪ 2018/09/19

Page 7: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 7 of 18 Form I3D-VDD001

Requirements:

Usable Operating Systems: ▪ Windows™ Ten Pro (64 or 32); Windows™ Eight Pro (64 or 32 bits without aero);

Windows™ Seven Pro (64 or 32 bits without aero); ▪ Compliant but not recommended Windows™ Vista Pro (64 or 32 bits without aero),

Windows™ XP Pro (32 bits), ▪ Compatibility of the hardware device, Counter Card, Link to DCC must be checked

separately with the hardware provider ▪ INCA3D installation and License Key Installation must be performed with Windows™

administrator right. MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini

o To avoid trouble with windows virtual store directory both softkomp.ini and vm.ini files are now located in “Inca3d\machine”

o This new location allows also using 2 different CAA files when working in multi machine mode

Multiplex Configuration: ▪ Working directories /CAD and /OperationSequence should be same shared directories on all

PC’s.

Dongle driver:

• Download at http://www.inspect-3d.com/english/software/download.htm - For Windows Vista, Seven, XP 1- Install first HASP HL Driver V5.22: haspusersetup.exe (V5.22) 2- Then install HASP4 Device Drivers V 5.22: hdd32.exe (HASP4 V 5.22)

Remarks

• Some of the functions and improvements described in this document may not be available for your INCA3D license depending on Package and options. Contact us for further details

Documentation updates: ▪ 2013-07-15 English Help Version E.1.21 ▪ 2013-07-15 German Help Version G.1.9 ▪ 2013-07-15 French Help Version F.1.12 ▪ 2013-07-15 Chinese Help Version C1.0

Valid Maintenance Date needed: ▪ 2018-06-01

Modifications & Bug fixes (V6300 – 2018-06-22):

Wishes Done: R6890:” Graphical programming --> Extract geometrical elements from surface : Roundslots are

extracted instead of Rectangles. Some of them are also not extracted.” Add sampling value for very small parts (Sampling Rectangle=0.1) DONE

R6919:” If calibration parameters are locally modified, user do not see that there are modified and is not able to reset the modification to use default calibration parameters of the sphere” DONE

R6926:” Pantec Eagle + Eagle Pad/SmartPad: Be able to do a Beep on the handbox when probe a point ” For the SmartPad one setting file of the SmartPad must be modified to allow beep FIXED

R6952:” Add the display of CMM Primus L 152515” DONE R6972:” Cloud. If the opened cloud is in separate file mode (for huge files):

- Add a button to open folder that contains the cloud points file - Add a button to open the cloud points file” DONE

R6902:” Add a menu in Operation sequence menu to open the directory of the current ops.” DONE

R6974:” When there is no alignment (in nominal and real) do not start automatic wizard.” DONE R6969:” In translator/creator, when I edit text in the search window would be useful to modify

directly TEXT inside the search window (when press enter).” DONE R6990:” When click on "New" in open window, never owerwrite an existing ops.” DONE

Page 8: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 8 of 18 Form I3D-VDD001

R6985:” Hotline Messenger: - MAP with already added file to avoid increasing log with duplicate files- CLEAN : only INCA should Clean the File when STARTED create a Backup with date in a folder- Do not add line when hidden session” DONE

R6994:” Add the new dates formats (date and time, only date, short date,….)” DONE R5313:” Curve profil or shape profile : ability to perform calculation without reference element,

means best fitting the shape or the curve” DONE

Fixed Bugs: R7033:” Arm or tracker: Inca3D display warning icon on current coordinate in the counter” FIXED R7106:” When select I++DME Manual the tool builder failed” FIXED R6892:” Allow to drag a PMI tolerance from the CAD property list (also in the search window) to a

tolerance in the action parameter window.” FIXED R6889:” Rack calibration icon is not protected according to the user profile” FIXED R6927:” In Machine,exe / IncaIPPServer.exe, when select Icon = Medium, Counter function

buttons have no BMP” FIXED R6911:” UCC error message, then user clicks OK to reset error and restart execution, sometimes

nothing happens, machine is standing” Now when click on OK in Machine Error Window, Inca3D wait that machine has been cleared and machine is ready to close the Machine Error Window. Done for drivers: I++DME, Pantec Eagle Pro, DCC Controller FIXED

R6870:” When selecting probe orientation by clicking on CAD surface, CTRL+R is not taken into account” FIXED

R6818:” PMI: Minmax box wrongly calculated when file contains PMI” FIXED R6960:” Cloud display in color of the tolerance. If user change the zot file the graphic is not

updated with new colors” FIXED R6959:” FDT in graphic : when not visible FDT text should be greyed like surface ref when not

visible” FIXED R6957:” PMI in graphic : when double click in treeview on FDT, the graphic center+zoom on FDT

But if you do it with popup menu it center only without zooming. Modify to center only without zooming” DONE

R6958:” FDT in graphic : when click a FDT in the treeview, it is not highlighted in the graphic view Highlighting FDT is not clear it turn to bold only maybe reversing color could be easier (and for white reverse to Grey)” FIXED

R6955:” Head rotation confirmation. Using the button in the counter it is not possible to re-active the rotation head validation” FIXED

R6980:” Try to click a cone on a face, sometimes the calclated Cone is Inner or Outer.” FIXED R6981:” Arm and tracker driver: When scan with single point action (Point on surface,,,,) counter

count of point in the counter is the double of count of point in Action parameters” FIXED R6982:” Arm Unable to create a new section by scanning points” FIXED R6983:” I load 2 CAD files : put File2 not visible in graphic parameter, then try to put on surface

not visible in File1 --> Files2 become visible again” FIXED R6995:” Last modification date is always the current date/time when execute the report action”

FIXED R6916:” Open an ops with several measures with creation and modification dates not equal.

When select in Measure window a previous mesure number, Inca3D can ask to save the ops. If click on Yes, Inca is saving the measure file opened. So it changes the modification date of the measure and if export (in QDas for example) we don't have the right date for the results.” FIXED

Page 9: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 9 of 18 Form I3D-VDD001

Modifications & Bug fixes (V6301 – 2018-09-18):

• PH20 :

o Abilty to create tool orientation with several strategies (like Revo head)

• Measuring pathwizard Circle:

o Abilty to reverse measuring clockwise/anticlockwise

o

Wishes Done: R7019:” Add extension *.ptp (Unigraphics) when slect a milling file” DONE R7021:” Star probe orientation: Select on default axis + angle of adjustement on the default axis

selected” DONE R7026:” I++: Perform always full probe calibration for PH20 and Revo head” DONE R7027:” Ability to use Plane of the referenced Circle in GDT action circularity” DONE R7031:” Remove buttons to manage .GTO files when there is no change tool holder and option

"Allow head orientation modification in tool manager" is not checked. If necessaryhere is an option exists to reactivate them in Inca3D Config (Machine)” DONE

R7032:” In tools manager grid, if there is no tool selected, when click on the filters button, select all corresponding tools” DONE

R6997:” Profile user : To create a user for each of us, we would like to be able to duplicate a user that contains all shared properties.” DONE

R7036:” In "Calibrate all tools" available in tools manager, be able to save sphere used for calibration” DONE

R7042:” MR12 driver: Introduce maximum time to calculate the probe vector after probe open status switch to ON. Aim is to avoid unexpected probe open status due to vibration or any other reason because in this case the MR12 current coordinate are frozen while the” Parameter can be set in advanced parameters of the MR12 driver in Inca3D config DONE

R7043:” MR12 driver: After head rotation always reset probe open status to avoid unexpected probe contact” DONE

R7099:” Add OMEGA Temperature sensor in Temperature driver for compensation” DONE R7100:” Temperature driver: Be able to define a min and max value when temperature device

return wrong values” Can only be set in Inca.ini. An error message is displayed after receiving several times wrong values (number can be set) DONE

R7103:” Be able to assign an output to Machine error state” DONE R5444:” PH20 ability to make automatic orientation (like revo strategy) for 5 axis probing -

example outer circle or outer curve” DONE

Page 10: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 10 of 18 Form I3D-VDD001

R7086:” In wizard of circle, in case of arc circle, possibility to reverse the start/end position and the direction of the measuring path calculation.” DONE

Fixed Bugs: R7011:” MR12 driver: When user probe very fast, point are missed and/or generate wrong probe

radius compensation” FIXED R7012:” When calibrate manually a star probe tip from action Change Probe in the OPS, Inca3D

display a dialog to know which tip must be calibrated even tip number is already define in the action” FIXED

R7013:” Save execution time of each action also in T&L mode” FIXED R7014:” Milling tool: In tools definition when click on filter "Tool component(s) template files", they

are not displayed. Works only if select the filter in probing tool then go back to milling tool” FIXED

R7015:” Pantec Eagle driver: If start Inca3D and Pantec Eagle is in milling mode, Pantec Eagle cannot be switched to any other mode than emergency. Only solution is to switch off the controller” FIXED

R7016:” RSM1 driver: Reduce communication between RSM1 driver and DCC controller:” FIXED R7017:” RSM1 driver: Get error if the RSM1 driver is not able to communicate with the DCC

controller (cable disconected, ...)” FIXED R7018:” During milling if get error that a point is not inside the software limits, Inca3D doesnot

switch MANUAL mode” FIXED R7023:” If set temperature and coefficient from an action in the OPS, when display temperature

dialog from counter, values are not set with latest define by the action” FIXED R7024:” Retrieve the probe orientation with sphere measuring path calculation does not work

properly with 5 axis head (PH20, REVO)” FIXED R7000:” Complex and shape alignment : Red/Green target does not work and should be also

available on actual. Add also the possibility to drag in the listview, not only in the combobox.” FIXED

R7025:” When click on Red target on Surfacic Alignement, after it is not possible with Element selection mode to select surfaces in the view.” FIXED

R7020:” When do a copy/past translation of a milling action, if Offset is set to "Fixed offset", apply the translation to the fixed offset” FIXED

R7029:” Wizard automatic calculation in case of NO active alignment : Neither modifications in Nominal nor click with the Red/Green target can trigger an automatic calculation (automatic calculation is done only if a parameter changes in the Path Wizard parameter” FIXED

R7030:” DCC Controller driver: Add the possibility to select the kind of move done for gage point” Selection can be done in Inca3D Config (advanced parameters of the driver). Useful with DCC controller on old bridge CMM FIXED

R6996:” Selection of alignment in the list does not highlight them in the graphic.” FIXED R6953:” Multipart + Display statistic label : when starting execution, Inca ask if user wants to

erase current meas file, if user says OK --> error message meas loaded by another module.” FIXED

R6954:” Multipart : if next meas already exist, question do you want to overwrite measure file, user says Yes, then Inca display starting window (with several choice, continue with existing already probe values,reset meas, meas+1 …) which is useless” FIXED

R6924:” Measured distance between 2 measured pts. In simple mode. If select Tol2768, an error message is displayed: Internal Error (3035) Pointer NULL.” FIXED

R7034:” Error when generating a report : pow: OVERFLOW error” Header contains formula exceeding computer capacity - UNIPPS Nr. 11371 FIXED

R7037:” In action "Call tool file", if GTO file is not available (see R7031/R6999) only display .TOOL selection” FIXED

R7045:” SB CNC driver: Sometimes during change tool holder sequence, machine doesnot move anymore” When used not optimized path for the sequence it works fine FIXED

R7047:” I++DME: When calibrate from the OPS, result of calibration does not contains information if tool is out of tolerance or not” FIXED

R7064:” The collison warning window is not always displayed at the same place in dual screenmode” FIXED

R7080:” Errors when create a measured cylinder with actual construct by n circles” FIXED R7061:” Curve point : In the result window it is written "Surface" instead of "Curve"” FIXED R7072:” The simplification menu "Show Graphic Main toolbar and all buttons" displays all the

selection buttons (point selection, gage point selection, legend arrow selection...) that are already in the popup selection button. Too much buttons are displayed.” FIXED

Page 11: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 11 of 18 Form I3D-VDD001

R7081:” In graphic window, the menu to Show/Hide buttons is always grayed.” FIXED R7060:” Wizard on an ellipse is not working when using Nominal set by user in simple probed

action.” FIXED R7059:” Default probing depth for cylinders is not properly saved.” FIXED R7079:” Create a cylinder measured with nominal "Kb " and actual construct by "list of circles"

then create a point construct by list of points and have "CylMeas1.List point" that is not reducible to POINT.” FIXED

R7083:” Polygon calculation improvement. Some calculation method failed and reversed probing vector” UNiPPS Number 11592 FIXED

R6984:” CAD with PMI : min max boxes are calculated regarding PMI (cartouche also) that generate trouble in best of the view and Plane display in section calculation and clipping plane. Calculate boxes only for CAD surface/geometry and Add a button to bestfit on PMI” FIXED

R7051:” Programmation of gage point. There is no Up Down arrow in XYZ edits” FIXED R7095:” DMO output : No management of the formula calculation for Part number, Part index and

Part serial number.” FIXED R7097:” Exportation of Header.Part serial number to a file using the action "Output Data in file" is

creating a boolean value” FIXED R7044:” With star probe, be able to deactivate tip(s) only for particular A&B position or probe(s)”

FIXED R7104:” Send to server each axis temperature instead of average temperature of the 3 axes”

FIXED R6584:” Cannot probe outer circle/cylinder by AB probing because always start/end gage point

inside cylinder/circle.” FIXED R6209:” Possibility to remove gage pts Before After in Wizard calculated for REVO head.” FIXED R7109:” Target of the current line and start line of a milling file are not displayed at the right

position in the graphic view when there is an alignment” FIXED R7093:” If an operation sequence name contains an extension that is not lower case (f.i XX.OPS

instead of XX.ops) then the dialog that displays all the measures contains only the current measure. There is no way to open a former measure.” FIXED

R7096:” Calibration tool operation. There is not result window when we execute the operation.” FIXED

R7052:” Not possible to create any gage point inside a section using the window "Define gage point". I have the error message "Multi entite creation : No opened action"” FIXED

R7118:” Add the possibility to move gage points by Mouse selection in the graphic like done for measuring path of circle in the measuring path editor (using red target).” FIXED

R7119:” When we select a list of points in the graphic and create probing operations with them : We execute them by clikcing on the button "Wizard apply and probe" ( a button with gears and a wizard) but the displayed button should be the execute button because” FIXED

Modifications & Bug fixes (V6302 – 2018-11-08):

• Execution time:

o Abilty to display current execution time elapsed.

▪ To be activated in paremeter Yellow + parameter

• Temperature Compensation:

o Ability to select several kind of temperature sensors to perform CMM and Part Temparture compensation

Page 12: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 12 of 18 Form I3D-VDD001

o User can also set lower and upper limit for temperature value

o

• Moving Gage point with the mouse

o Ability to click an existing gage point to move it wth the mouse (click target icon near XYZ)

o Inca draw X, Y and Z axis colored in the machine limit area

Page 13: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 13 of 18 Form I3D-VDD001

• Calibration Action

o Ability to add a calibration action to calibrate all the probe used in current operation sequence

o

• Parking Position

o Parking position can now be defined with some priority on the axis sequence (access in counter window 3rd page). Useful to always start and end the programs at the same position

o In example below, the CMM will move up on Z 1st, than move along X to position 50, Y is deactivated so CMM will keep Y position as it is

o

• Gage Point without Probe

o This new action allows to create gage in machine coordinate system without taking probe offset into account.

o Available in “Prepare Tabsheet”

o

o Gage Point to Parking Position are now managed in this action

o

• Permanent Log File : Ability to activate permanently log file for machine driver

Page 14: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 14 of 18 Form I3D-VDD001

• Distance Plane/Plane and Line/Plane

o Add a new calculation: User can now calculate distance with 1st Plan as the Reference (Main Plane) meaning that INCA3D will calculate the distance of the 2nd to the 1st one in the direction of the First one. This method avoids to get trouble on the distance if the second plane can only be probed on a very small area implying that plane orientation is not good.

o Parameter is available in “Yellow +” tab sheet

o

Wishes Done: R7134:” Global modifications window : Add filtering in the probes listview and vertical resizing.

Sometime the horizontal resizing is wrong.” DONE R7139:” For I++ DME driver with Renishaw, add function RWSuspend() and RWResume() to the

popup menu of the counter” DONE R7122:” Handbox management : Button EXECUTE should ask if you want to go to execution

mode when you are in TEACH&PROBE (and no action is opened)” DONE R7146:” Add an option to save permanently INCA3D logs” DONE R7138:” New management of T° driver and T° CAA. Be able to select one T° driver for CMM and

one for the Part. Be able to read T° from Machine driver (I++ and Pantec Eagle only for the moment).” DONE

Fixed Bugs: R7111:” PMI Information is avaialble in middle click but not in treeview popup” FIXED R7123:” I++ DME : In action Change Probe when tool used is a star user can select the tip of the

star. It must be deactivated because star selection is not possible with I++ DME” FIXED R7124:” I++ DME : In tools maneger when tool definition has a star Inca3D allow to select tip 1

event there is no tip 1” FIXED R7110:” PMI set all not visible, sometimes some PMI stay visible” FIXED R7113:” Diffusor CAD file : Select the 3 points in the CAD treeview; pop up menu send to OPS or

Send to selection windows … Nothing happens” FIXED R7115:” Diffusor CAD file : When selecting a tolerance in tolerance tabsheet some PMI are not

R7133:” Leica tracker: Unable to used F2,,F12 with the remote control” FIXED R6883:” Debug Time limitation does not work anymore, debug is active anyway. Debug option

modification taken into account only after restart.” FIXED R7140:” Renishaw UCC server: When requalify one tool of an assembly all other tools of the

same assembly are decalibrated” FIXED We allow now to requalify and select tools not calibrated

R7137:” Label filter cannot be save anymore in 6301. Try with filter by reference” FIXED R7144:” If action change probe has been set with Tip information and tool is not anymore a star

probe, when tip used is 1, do not display error message” FIXED R7145:” Pantec Eagle driver : error 83 is not documented” FIXED R7147:” When press F5 to add a gage point action in the OPS, Inca3D display an error message”

FIXED R7148:” Softko32.dll / Softko64.dll version 0.0.0.87” FIXED R7152:” Measuring path editor. Add a red/green target button to select and move one by one

measuring path probing points and measuring path gage points.” FIXED R7153:” ACR3+FCR25+TM25-20 : When select only FCR25 position used with TP20 module,

Inca3D display MCR20 even there is no MCR20 calibrated” FIXED Now "TP20 modules” is displayed

Page 15: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 15 of 18 Form I3D-VDD001

Modifications & Bug fixes (V6303 – 2018-11-20):

• New action Point project on geometrical entities

o Add a new action Point projected on circle, rectangle, roundslot, ellipse, polygon, Cylinder, cone and sphere

• Add parameters “recalculate probed point compensation” for Rectangle, Roundslot, Ellipse, Cylinder, Sphere, Torus, Curve, Cloud of Points

• Export Filename : Ability to create export file name according to “Use customizable Header fiels”

Fixed Bugs:

R7160:” Error message displayed saying that manual temperature is not available” FIXED

R7161:” When you are in Form Deviation view and switch back to Label view with List of different kinds of page, the Cad is not redrawing in the view.” FIXED

R7164:” Zéro on sphere center is not activated when start Inca3D. User must reactivate it from the counter or tool manager.” FIXED

R7162:” Some FDTs in file 16192_PAVE_1_PAVE_RAPPORTE_1_MATRICE_.stp have same name, cannot display all correctly in the graphical view.” FIXED

R7163:” FDTs from file nist_ftc_06_asme1_cr3000_rd.prt.1 are displayed very small (inch coefficient) in the graphical view” FIXED

R7165:” ZAK limit are fixed to A: +/-120 and B: +/-180 (ZAK manage by DCC Controller). With SB CNC limit are different. User with SB CNC and SB CNC ZAK cannot use value like B=+/- 360°” Limit are fixed by the machine driver if the driver return A&B limits or can be forced from Inca.ini if necessary FIXED

R7166:” When click on button save as or new for a tool file propose a tool file name that doesnot exist” FIXED

R7153:” ACR3+FCR25+TM25-20 : When select only FCR25 position used with TP20 module, Inca3D display MCR20 even there is no MCR20 calibrated ” Now we display "TP20 modules" FIXED

R7167:” Add the possibility to make report file names (or directories) using the 10 fields that can be defined by the user in the header action (5 in Ops + 5 in Meas)” FIXED

R7151:” Text in preview is very small ! Very big screen resolution and Text % is 175% in Windows. Not take into account in Preview” FIXED

Page 16: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 16 of 18 Form I3D-VDD001

Modifications & Bug fixes (V6304 – 2019-01-09):

• New Action: Cone by 2 circles

• Pantec Driver

o Pantec Eagle Driver V4:

▪ Warning it need installation of the new Pantec Driver (http://www.inspect-3d.com/drivers/machinedriver/pantec/PantecEagle/Pantec.Cmm.Driver_v4.0.2.3_x86.msi)

▪ Must be changed manually in configuration

o Old Driver V2 is still available and still NECESSARY for MILLING

o Manage Pantec GEC CAA including temperature sensors

• Display information (hand icon) about manual execution in Teach&Measure

• Improvement in search windows in treeview (CTRL-F)

o Ability to display list of result

o ability of adding the successive searches

o Abilty to open in editor , entity mentionned in an error message

Page 17: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 17 of 18 Form I3D-VDD001

o Ability to open referenced entities from pop-up menu

• Display simplification (access “Menu Windows /Simplification/user interface simplification”)

o Add management of the “starting window option” and “on machine error windows”

o

o

Wishes Done: R7150:” Add a menu to display the out of tolerance window (the red triangle) of the complete

operation sequence if this window has been closed.” DONE R7173:” Ability to modify the support plane in Revo wizard parameter for curve actions” DONE R7186:” Possibility in Action parameters window, to have 'Select in editor' in the List of CoordSyst and

on all list of elements. Have graphic highlight and filtering in list of CoordSyst.” DONE R7169:” Report : Remove "export directory" it seems useless, always "export directory" true” DONE R7180:” Do not display any more the message "Operation file already used by another computer" if

this computer is not another computer but the current computer.” DONE R7201:” Output result to DMO : Do not convert all entitie names to upper case” DONE R7202:” Output results to BMWIpp format” DONE

Page 18: Version Descritpion Document...2019/01/09  · MORA CAA: Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory

VDD_INCA3D_English_2019-01-09_V_6_3_0_4.doc Page 18 of 18 Form I3D-VDD001

Fixed Bugs: R7170:” Execution information (the progressbar with the number of actions displayed in the action

tool bar) are wrong if an error occur and user click on 'Retry' button.” FIXED R7171:” After calculation of optimization; Actions after optimization becomes with question mark”

FIXED R7172:” Action cone by 2 circles” FIXED R7121:” Handbox management : Button DELETE LAST MEASPATH ELEMENT does not work in

execution (in Pantec but probably alos other)”Before was working only when teach an action in execution. FIXED

R7175:” In T&L, open an action ChangePrb to active the tool orientation, after clicking on Apply button, open quickly an existing action GagePoint, sometimes coordinate of the gage point are not displayed, X, Y and Z are still equal to 0.0” FIXED

R7159:” Wen you set Form Dev. Error 0,001 for ex. and you are in the execution mode than you do not get error message displayed even it is activated” FIXED

R7176:” In the caption of the calibation window, add before the tool reference the name of tool(s) holder(s)” FIXED

R7177:” Send tool offset to Pantec Eagle CAA”FIXED R7178:” Possibility to filter the display of FDT elements according to views/captures” FIXED R7168:” With some Solidworks files, entity color are not recovered correctly.”Primus SW files FIXED R7191:” Error mesage #1.406 when opening measured distance between 2 measured planes or 2

lines” FIXED R7195:” When used a HLM from customer that used I++Server CAA or Pantec CAA, when switch to

VirtualCMM used VirtualCMM CAA (doing nothing) but allow to make test as at customer place” FIXED

R7196:” OMEGA Sensor driver: Read more often T° of the sensor to always get the latest value, not the T° few second before” FIXED

R7197:” KREON Scanner: At end of scan, does not stop scanning action” FIXED R7198:” DCC controller : When firmware is upper to 2.14 use movetype 32 by default for 5 axis

moves” FIXED R7204:” In the window "Graphic parameters", with some computers, the buttons Ok / Cancel / Apply

are missing. The only way to store the modifications is the press "Return" keyboard key.” FIXED

R7205:” Open an action Change Probe, created with a ZAK configuration with a PH configuration. When click on button Grid angle selection Inca3D display a message GUIToolManager Exception” FIXED

R7193:” In V6303 Graphic cannot be saved in JPEG Format: “error in saving JPEG format”” FIXED R7187:” When we display an error message like "Entity xxxxx is not calculated", add a button to

select xxxxx in the editor to give the possibility to open easily the entity xxxxx.” FIXED R7207:” When select several points in a cloud, we get all points as individual one. Previously we got

only 1 entity with sub list of points.”Pb since 6.2.0.7 FIXED R7212:” HTML report : start with unexpected /HEAD> message and picture may not be displayed

when export with meas number” FIXED R7208:” The security planes, obtained from Cad min max boxes and used for gage point, take into

account the FDT elements in the graphical view. Should not.” FIXED R7209:” SB PT100 driver : unable to communicate with SB PT100 device” FIXED