Title: Changing the Threshold value only for the specific Checkpoint. (Make it Static) – (Oracle Probe)Case : 00114521
Product Family Nimsoft Monitor
Component oracleComponent Version 4.53TPlatform WindowsPlatform Version 2008
Description Information
SubjectSet oracle probe alarm value to single database but the database alarm value changes globally with single database. We do not want the database alarm value changes globally.
Description
Solution:
Step by step Screenshots:
1. Go to Oracle Probe >>
2. under profile tab – double click on any profile >>
3. Under profile checkpoints – we have Checkpoint, Description, Type.
4. We have to change the checkpoint from Template to Static.“Type” – If we want to change only a single threshold without making any change to the other profiles then we have to Right click on the checkpoint and change the specific checkpoint from template to static. Now the change will not affect globally.
5. Now the “Type” has been changed from Template to Static.
6. Now double click on the checkpoint and change the “Threshold Value”.
7. This Threshold value is only for that specific checkpoint and will not affect globally.
Thank You,Viquaruddin Mohammed.