NEW PARK AMENITIES BUILDING
21 BOULEVARD AVE
CELORON , NY 14720
VILLAGE OF CELORON
LABELLA PROJECT NUMBER: 2182911
ISSUED FOR:
BID / CONSTRUCTION
PROJECT LOCATIONGENERAL
G-001 COVER SHEET
G-002 NOTES, SYMBOLS AND ABBREVIATIONS
CIVIL
C-100 PLANTING PLAN
C-101 SITE GRADING PLAN AND DETAILS
STRUCTURAL
S-001 SYMBOLS, ABBREVIATIONS, GENERAL NOTES & DESIGN CRITERIA
S-002 TYPICAL CONCRETE & MASONRY DETAILS
S-003 TYPICAL WOOD FRAMING DETAILS
S-101 FOUNDATION / FIRST FLOOR PLAN
S-102 ROOF FRAMING PLAN
S-201 SECTIONS
ARCHITECTURAL
A-101 FLOOR PLAN AND SCHEDULES
A-102 REFLECTED CEILING PLAN, ROOF PLAN AND DETAILS
A-201 EXTERIOR ELEVATIONS
A-301 SECTIONS AND DETAILS
MECHANICAL
M-001 MECHANICAL LEGEND SHEET
M-101 MECHANICAL PLANS
ELECTRICAL
E-001 ELECTRICAL NOTES, SYMBOL LEGEND, & ABBREVIATIONS
E-100 ELECTRICAL SITE PLAN
E-101 ELECTRICAL FLOOR PLAN
E-102 ELECTRICAL SCHEDULES
PLUMBING
P-001 PLUMBING LEGEND SHEET
P-002 PLUMBING SITE PLAN
P-101 PLUMBING PLAN
P-501 PLUMBING DETAILS
DRAWING INDEX
NYS DOS Contract Number: C1001143
Note: This drawing was prepared with funding provided
by the New York State Department of State under Title
11 of the Environmental Protection Fund.
UNLESS OTHERWISE NOTED, ALL MASONRY DIMENSIONING IS NOMINAL TO FACE OF MASONRY, ALL NON-MASONRY DIMENSIONING IS TO FACE OF PARTITIONS OR WALLS AND ALL CONCRETE DIMENSIONING IS FACE TO FACE OF WALL.
ALL DIMENSIONS ARE TO THE OUTSIDE FINISH SURFACE OF WALLS OR TO COLUMN CENTERLINES.
ALL DIMENSIONS ARE FINISHES DIMENSIONS FROM FINISH FACE OF GYPSUM BOARD OR SCHEDULED WALL FINISH UNLESS OTHERWISE NOTED.
PROVIDE CONCEALED BLOCKING IN ALL STUD PARTITIONS AND WALLS BEHIND SURFACE FOR SEMI-RECESSED, FULLY RECESSED OR SURFACE MOUNTED ACCESSORIES AND MILLWORK.
DIMENSIONS NOTED AS “CLEAR” ARE TO FINISHED SURFACE AND ARE CRITICAL FOR ACCESSIBILITY REQUIREMENTS OR BUILT-IN FURNISHINGS.
CONTRACTOR SHALL FIELD VERIFY FINISHED DIMENSIONS AND CLEARANCES IN SPACES INDICATED TO RECEIVE BUILT-IN FURNISHINGS OR CASEWORK PRIOR TO FABRICATION.
ALL ENDS OF MASONRY WALLS THAT WILL BE EXPOSED TO VIEW UPON COMPLETION OF WORK SHALL BE PLAIN END UNITS.
FINISHED DOOR OPENINGS SHALL BE NOMINAL 6” FROM FINISHED CORNER OF ROOM EXCEPT WHERE DIMENSIONED OTHERWISE.
SEALANT SHALL BE PROVIDED AT THE INTERIOR AND EXTERIOR PERIMETER OF ALL WINDOWS, DOOR FRAMES, LOUVERS OR OTHER ITEMS INSERTED IN AN EXTERIOR WALL.
WOOD USED FOR BLOCKING OR OTHER PURPOSES ON OR ABOVE THE ROOF DECK, WITHIN 2'-0” OF GRADE AND IN OTHER LOCATIONS OUTSIDE THE BUILDING ENVELOPE WHERE EXPOSED TO THE WEATHER SHALL BE PRESSURE TREATED LUMBER OR PLYWOOD.
INSTALL ALL WORK AS INDICATED AND VERIFY EXACT LOCATION AND ELEVATIONS ON THE JOB.
DO NOT SCALE DRAWINGS. REFER TO DIMENSIONS AND SPECIFIED MATERIALS. CONTACT THE ARCHITECT IF ADDITIONAL DIMENSIONS ARE REQUIRED.
COORDINATE ALL DOOR HARDWARE, TRIM AND FINISHES TO MEET INTENT AND COMPLIANCE.
FIRST FLOOR LEVEL DATUM ELEVATION (0'-0") IS EQUAL TO ACTUALELEVATION (1312.5'). ARCHITECTURAL ELEVATIONS U.O.N. ARE TAKEN FROM FINISHED FIRST FLOOR LEVEL DATUM ELEVATION (0'-0").
TRUSS IDENTIFICATION SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH TITLE 19 NYCRR PART 1264 AND APPENDIX H OF THE FIRE CODE OF NEW YORK STATE 2010. TRUSS IDENTIFICATION SIGNS SHALL BE LOCATED AT BUILDING ENTRANCE DOORS, EXTERIOR DISCHARGE DOORS AND FIRE DEPARTMENT HOSE CONNECTIONS.
A. ATTACH SIGN TO FACE OF DOOR, OR ATTACHED TO A SIDELIGHT OR FACE OF THE BUILDING NOT MORE THAN 12 INCHES HORIZONTALLY FROM THE LATCH SIDE OF THE DOOR JAMB, AND NOT LESS THAN 42 INCHES NOR MORE THAN 60 INCHES ABOVE THE ADJOINING WALKING SURFACES.
B. ATTACH SIGN AT EACH END OF A ROW OF DOORS AT A MAXIMUM HORIZONTAL DISTANCE OF 12 FEET BETWEEN SIGNS, AND NOT LESS THAN 42 INCHES NOR MORE THAN 60 INCHES ABOVE THE ADJOINING WALKING SURFACE.
C. AT FIRE DEPARTMENT HOSE CONNECTIONS ATTACH TO THE FACE OF BUILDING, NOT MORE THAN 12 INCHES HORIZONTALLY FROM THE CENTER LINE OF THE FIRE DEPARTMENT HOSE CONNECTION, AND NOT LESS THAN 42 INCHES NOR MORE THAN 60 INCHES ABOVE THE ADJOINING WALKING SURFACE.
D. SIGNS IDENTIFYING THE EXISTENCE OF TRUSS CONSTRUCTION SHALL CONSIST OF A CIRCLE 6 INCHES IN DIAMETER, WITH A STROKE WIDTH OF 1/2 INCH. THE SIGN BACKGROUND SHALL BE REFLECTIVE WHITE IN COLOR. THE CIRCLE AND CONTENTS SHALL BE REFLECTIVE RED IN COLOR, CONFORMING TO PANTONE MATCHING SYSTEM (PMS) # 187. WHERE A SIGN IS DIRECTLY APPLIED TO A DOOR OR SIDELIGHT, IT MAY BE A PERMANENT STICKER OR DECAL. SIGNS NOT DIRECTLY APPLIED TO DOORS OR SIDELIGHTS SHALL BE STURDY, NON-FADING, WEATHER RESISTANT MATERIAL.
F. SIGNS SHALL CONTAIN THE ROMAN ALPHANUMERIC DESIGNATION OF THE CONSTRUCTION TYPE OF THE BUILDING, IN ACCORDANCE WITH THE PROVISIONS FOR THE CLASSIFICATION OF TYPES SET FORTH IN SECTION 602 OF THE BUILDING CODE OF NEW YORK STATE 2010, AND AN ALPHABETIC DESIGNATION FOR THE STRUCTURAL COMPONENTS THAT ARE OF TRUSS CONSTRUCTION AS FOLLOWS:
"F" SHALL MEAN FLOOR FRAMING, INCLUDING GIRDERS AND BEAMS
"R" SHALL MEAN ROOF FRAMING
"FR" SHALL MEAN FLOOR AND ROOF FRAMING
G. THE CONSTRUCTION TYPE DESIGNATION SHALL BE PLACED AT TWELVE O'CLOCK POSITION OVER THE STRUCTURAL COMPONENT DESIGNATION, WHICH SHALL BE PLACED AT THE SIX O'CLOCK POSITION. REFER TO FOLLOWING SYMBOL FOR THIS BUILDING:
GENERAL ARCHITECTURAL NOTES
IIBR
ROMAN ALPHANUMERIC DESIGNATION OF CONSTRUCTION
ALPHABETIC DESIGNATION FOR THE STRUCTURAL COMPONENTS THAT ARE TRUSS CONSTRUCTION
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
CONSTRUCTION SHALL CONFORM TO THE “NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE”, LATEST REVISION, THE NEW YORK STATE ENERGY CODE AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THE PROJECT IS BEING CONSTRUCTED.
CONSTRUCTION SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND REGULATIONS.
ALL DRAWINGS ARE GRAPHIC REPRESENTATIONS OF APPROXIMATE LOCATIONS OF NEW MATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL CONDITIONS PRIOR TO COMMENCEMENT OF WORK.
CONTRACTORS ARE RESPONSIBLE FOR ALL MATERIALS, CONSTRUCTION METHODS AND CRAFTSMANSHIP.
CONTRACTORS ARE TO VERIFY ALL EXISTING CONDITIONS, REQUIREMENTS, NOTES, CODES AND DIMENSIONS, PRIOR TO THE START OF CONSTRUCTION AND SHALL NOTIFY THE ARCHITECT IF CONDITIONS VARY FROM THOSE SHOWN ON THE DOCUMENTS.
THOROUGHLY COORDINATE WORK WITH OTHER TRADES AND DETERMINE THE EXACT ROUTE AND LOCATION OF UTILITIES, MATERIALS AND EQUIPMENT BEFORE FABRICATION AND INSTALLATION.
CONTRACTORS PROVIDE ALL BLOCKING, FURRING AND SHIMMING FOR INSTALLATION AND COMPLETION OF WORK.
ALL NEW WORK SHALL BE PLUMB, LEVEL AND SQUARE. SCRIBE AND MAKE FIT ALL NEW TO EXISTING.
CONTRACTORS VERIFY ALL DIMENSIONS BEFORE ORDERING MATERIAL OR DOING WORK. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS AND MEASUREMENTS INDICATED ON THE DRAWINGS.
ALL DETAILS ARE SUBJECT TO CHANGE DUE TO EXISTING FIELD CONDITIONS. CONTRACTOR MUST NOTIFY ARCHITECT OF SAME.
THESE DRAWINGS DO NOT PURPORT TO SHOW ALL ITEMS AND PROCEDURES REQUIRED FOR A COMPLETE INSTALLATION. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE GENERAL ARCHITECTURAL DESIGN CONCEPT, THE LOCATION/DIMENSIONS OF THE CONSTRUCTION AND MAJOR ELEMENTS OF CONSTRUCTION.
CONTRACTORS ARE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS ASSOCIATED WITH THE WORK OF THEIR CONTRACT.
ITEMS NOTED AS 'BY OWNER” ARE TO BE FURNISHED AND INSTALLED BY THE OWNER OR THE OWNER'S VENDOR.
GENERAL CONSTRUCTION NOTES:1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
TOILET TISSUE/ GRAB BAR
GRAB BAR MIRROR PAPER TOWELDISPENSER /
WASTE CONTAINER
VISIBLEALARM SIGNAL
LAVATORY
INSULATE HOT WATER & DRAIN PIPES (TYP.)SEE PLUMBING DWGS. (B
OT
TO
M O
F R
EFL
. S
UR
FAC
E)
SEAT HGT.
FLOOR MOUNT W.C.
FINISH FLOOR
FACE OF WALL
SOAP DISPENSER
CL
EYE LEVEL
HANDLE
ARMREST
STD. WHEELCHAIR DIMENSIONS
REQUIREDCLEARSPACE
48
" IF
DO
OR
HA
SC
LOS
ER
& L
AT
CH
54
" IF
DO
OR
HA
SC
LOS
ER
& L
AT
CH
CLEARFLOORSPACE
12" MIN. IF DOOR HASCLOSER & LATCH
LAVATORY CLEARANCE DOOR CLEARANCE(SIDE APPROACH)
DOOR CLEARANCE (FRONT APPROACH)URINAL
HC
H
GT
.
HC
HG
T.
TO CONTROL MECHANISM
DRINKING FOUNTAIN
TO CONTROL MECHANISM
FACE OF WALL
REQUIREDCLEARSPACE
REQUIREDCLEARSPACE
REQUIREDCLEARSPACE
SPOUT HEIGHT
WHEELCHAIR ACCESSIBLE
STANDARD/STANDING
CL
14"-19" @ CHILDREN'S
11"-17" @ CHILDREN'S
36
"
15
"
(MIN
.)
8"
42"12"
17
" T
O 1
9" 4
0"
27
" C
LEA
R
34
" M
AX
.
40
" (M
AX
.)
17
"
40
"
88
" M
IN.
/ 9
6"
MA
X
24"
18"
36
"
26
"
42" 6"
18
"8
"
19
" 27
" 43
" -
51
"
30
"36
"
27
" M
IN.
9"
MIN
.
6" MAX. TOE CLR.
8" MIN. KNEE CLR.
17" MIN.
24"
(MIN.)
32"
(CLEAR)
42
" (M
IN.)
22"
(MIN.)
48
" (M
IN.)
15" MIN.
17
" M
IN.
19
" M
AX
.
18" (MIN.)32"
(CLEAR)
48
" (M
IN.)
60
" (M
IN.)
48
" M
IN.
30" MIN.
40"
40
"
17
"
24
" S
TA
ND
AR
D
44
"
27
" C
LR.
34
" M
AX
.
11"
MIN.
36
" M
AX
.
38
" M
IN./
43
" M
AX
.
1'-6"18
"
NOTES:1. LOCATE SIGN ON WALL ON LATCH SIDE OF DOOR MAXIMUM 18" FROM EDGE OF DOOR.2. PROVIDE VANDAL-RESISTANT FASTENERS OR ANCHORS TO SUIT MOUNTING SURFACE.
WHITE
BLUE OR BLACK BACKGROUND
CENTERED @ 5'-0" A.F.F.
WHITE
6" - 8" 6" - 8"
6" -
8"
6" -
8"
GENERAL SIGNAGE DETAIL:
MATERIAL SYMBOLS
CONCRETE MASONRY UNITS(CMU)
CONCRETE
BRICK
CEMENT, SAND, GROUT, PLASTER, OR GYPSUM WALL BOARD
EARTH
STONE, GRAVEL, OR POROUS FILL
CARPET
PLYWOOD
WOOD (FINISHED)
WOOD (ROUGH)
RIGID INSULATION
BATT. OR LOOSE INSULATION
STEEL
WOOD (BLOCKING)
PARTICLE BOARD
ARCHITECTURAL DRAWINGS SYMBOLSMATCH LINE
ELEVATION LINE
COLUMN LINE REFERENCES
DOOR TAGS
BUILDING SECTIONS
WALL SECTIONS
ARCHITECTURAL ABBREVIATIONSA
0
X-XXX
0
X-XXX
0
X-XXX
21DETAIL NO
SHEET NO
DETAIL NO
SHEET NO
A
B
FINISH FACE OF NEW WALL(U.O.N.)
NOMINAL FACEOF MASONRY AND CONCRETE
WALL / PARTITIONS(U.O.N.)
CENTERLINE OF NEW COLUMNS(U.O.N.)
TYPICAL PLAN DIMENSIONING
NOMINAL FACE OF EXISTING PARTITION
(U.O.N.)
B
A: AreaAB: Anchor BoltABV: AboveACC: AccessACOUST: AcousticalACR: AcrylicACST: AcousticACT: Acoustical TileAD: Access DoorADH: AdhesiveADJ: Adjust, Adjustable, AdjacentAFF: Above Finished FloorAGGR: AggregateALT: AlternateALUM: AluminumANOD: AnodizedAP: Access PanelAPPROX: ApproximateACT: Acoustical Ceiling Tile
BDRM: BedroomBETW: BetweenBF: Board FootBIT: BituminousBLDG: BuildingBLKG: BlockingBOT: BottomBPL: Bearing PlateBRG: BearingBRK: BrickBRZ: BronzeBS: Both SidesBSMT: BasementBUR: Built-up Roof
C/C: Center to CenterCAB: CabinetCAR: CarpetCAV: CavityCCW: Counter ClockwiseCCTV: Closed Circuit TVCEM: CementCER: CeramicCF: Cubic FeetCHAM: ChamferCJ: Control JointCK: CaulkingCL: CenterlineCLG: CeilingCLKG: CaulkingCLR: ClearCLR OPG: Clear OpeningCMT: Ceramic Mosaic TileCMU: Concrete Masonry UnitCOL: ColumnCONC: ConcreteCONSTR: ConstructionCONT: ContinuousCONTR: ContractorCOP: CopperCPR: CopperCPT: CarpetCT: Ceramic TileCW: Clockwise
EA: EachEB: Expansion BoltEE: Each EndEF: Each FaceEIFS: Exterior Insulation and Finish SystemEJ: Expansion JointEL: Elevation, ElevatorELEC: ElectricalELEV: Elevator, ElevationENCL: EnclosureEPDM: Ethylene Propylene Diene MonomerEQ: EqualEQUIP: EquipmentETR: Existing To RemainEW: Each WayEXG: ExistingEXH: ExhaustEXIST: ExistingEXP: Exposed
GA: Gauge, GageGALV: GalvanizedGC: General ContractorGL: GlassGL BLK: Glass BlockGRND: GroundGRTG: GratingGVL: GravelGYP: GypsumGYP BD: Gypsum Board
WINDOW TAG/LOUVER TAG
DETAIL SECTIONS0
X-XXX
DETAIL NO
SHEET NO
P. LAM: Plastic LaminatePAR: ParallelPBD: Particle BoardPERIM: PerimeterPERP: PerpendicularPL: PlatePLBG: PlumbingPLYWD: PlywoodPLUMB: PlumbingPR: PairPREFAB: PrefabricatedPRES: PressurePRESS: PressurePRMLD: PremoldedPRTN: PartitionPSF: Pounds per square footPSI: Pounds per square inchPT: PAINTPTD: Painted, Paper Towel DispenserPTD/R: Combination Paper Towel Dispenser/ReceptaclePTN: Partition
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
DETAIL CALL OUTS
DETAIL NO0
X-XXX
DETAIL NO
SHEET NO
3
X-XXX2 4
1
SHEET NO
WALL TYPE
ROOM TAGROOM #
ROOM AREA
REVISION SYMBOL AND CLOUD
C
D
E
F
G P
H
I
J
L
M
N
O
Q
R
S
T
DBL: DoubleDEG: DegreeDEMO: DemolitionDF: Drinking FountainDIAG: DiagonalDIA: DiameterDIAM: DiameterDIFF: DiffuserDN: DownDR: DoorDWG: DrawingDWGS: DrawingsDWR: Drawer
FB: Face BrickFD: Floor drainFDC: Fire Department ConnectionFDN: FoundationFDTN: FoundationFE: Fire ExtinguisherFEC: Fire Extinguisher CabinetFFE: Finished Floor ElevationFF&E: Fixtures, Furnishings & EquipmentFFL: Finished Floor LineFGL: FiberglassFHC: Fire Hose CabinetFIN: Finish, finishedFIXT: FixtureFL: FloorFLR: FloorFO: Finished OpeningFOF: Face of FinishFOS: Face of StudsFP: FireproofFRT: Fire RetardantFT: Foot, Feet,FTG: Footing, FittingFURN: Furnish, FurnitureFURR: Furring
HDCP: Handicapped (better called "Accessible")HDW: HardwareHDWD: HardwoodHGT: HeightHM: Hollow MetalHORIZ: HorizontalHR: HourHWD: Hardwood
ID: Inside DiameterIN: InchINCL: IncludeINFO: InformationINSTL: InstallINSUL: InsulationINT: InteriorINTERM: Intermediate
JAN: JanitorJC: Janitor's ClosetJT: Joint
LAB: Laboratory, LaborLAV: LavatoryLB: Pound (weight)LBL: LabelLINO: LinoleumLNTL: LintelLVT: Luxury Vinyl Tile
MAINT: MaintenanceMAN; ManualMAR: MarbleMARB: MarbleMAS: MasonryMAT: MaterialMATL: MaterialMAX: MaximumMECH: MechanicalMEMB: MembraneMFD: ManufacturedMFG: Manufacturer, ManufacturingMFR: Manufacture, ManufacturerMI: Malleable Iron, MilesMIKE: MicrophoneMIN: MinimumMIR: MirrorMISC: MiscellaneousMK: MarkML&P: Metal Lath & PlasterMLD: MoldingMLDG: MoldingMM: MillimeterMMB: MembraneMO: Masonry OpeningMOD: ModuleMONO: MonolithicMOV: MovableMP: Metal Acoustical PanelMPS: Medium Pressure SteamMR: Mop ReceptorMRD: Metal Roof DeckMT: Mount, MountedMTD: MountedMTL: Material, MetalMTR: MotorMUL: MullionMULL: MullionMV: Mercury VaporMWP: Maximum Working PressureMWK: Millwork
N: North, NitrogenNAP: NapkinNAT: NaturalNATL: NaturalNB: "Nota Bene" Latin phrase for "Take Special Note"NC: Normally Closed, Noise CriteriaNEC: National Electrical CodeNEUT: NeutralNF: Near FaceNFWH: Non-freeze Wall HydrantNI: NickelNIC: Not In ContractNK: NeckNMT: Non-MetallicNO: Number, Normally OpenNOM: NominalNR: Noise ReductionNRC: Noise Reduction CoefficientNTS: Not To Scale
OB: ObscureOBS: ObscureOC: On CenterOD: Outside DiameterOF: Outside FaceOFF: OfficeOH: OverheadOHD: Overhead DoorOPNG: OpeningOPP: OppositeOPP H: Opposite HandO.S.C.I. Owner Supplied,
Contractor Installed
QUAL: QualityQT: Quarry Tile, QuartQTY: Quantity
RB: Rubber BaseRCP: Reflected Ceiling PlanRD: Roof Drain, Round, Receptacle Distribution PanelREBAR: Reinforcing BarREF: Refer, Reference, RefrigeratorREFL: Reflected,REFR: Refrigerate, RefrigeratorREINF: Reinforcement, or ReinforceREQD: RequiredRESIL: ResilientRF: RoofRGH: RoughRGH OPNG: Rough OpeningRO: Rough OpeningRT: Rubber Tile
SALV: SalvageSCHED: ScheduleSF: Square FootSHR: ShowerSHT: SheetSPEC: Specification, SpecificationsSPECS: SpecificationsSQ: SquareSS: Stainless SteelSTC: Sound Transmission ClassSTD: StandardSTL: SteelSTOR: StorageSTRT: StraightSTRUC: StructuralSTRUCT: StructuralSUR: SurfaceSUSP: Suspended, Suspend
T&B: Top and BottomT&G: Tongue & GrooveTB: Towel BarTD: Trench DrainTERR: TerrazzoTHK: Thick, ThicknessTHRU: ThroughTLT: ToiletTPD: Toilet paper DispenserTPH: Toilet Paper HolderTPTN: Toilet PartitionTYP: TypicalTZ: Terrazzo
UNFIN: UnfinishedUNO: Unless Noted OtherwiseUON: Unless Otherwise NotedUP: UnpaintedUR: Urinal
VAT: Vinyl Asbestos TileVBC: Vinyl Base (Coved)VCT: Vinyl Composition TileVERT: VerticalVEST: VestibuleVIF: Verify In the FieldVT: Vinyl TileVTR: Vent Through RoofVWC: Vinyl Wall Covering
W/: WithW/O: WithoutWAINS: WainscotWC: WaterclosetWD: Wood
U
V
W
A101
1SIM
CS12.0b
W-
ROOM NAME123
150 SF
100
KEYNOTE###
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/23
/201
9 3
:14:
01
PM
C:\
Use
rs\t
eklu
m\D
ocum
ents
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg-
tekl
um(R
ecov
ery)
.rvt
G-002
NOTES, SYMBOLS &
ABBREVIATIONS
TEE
DNM
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
© 2019 LaBella Associates
TYP. MOUNTING FOR HC ACCESSIBLE FIXTURES
SCALE: 1" = 1'-0"G-002
1 TOP OF CMU. WALL TYP.
Revisions
NO: DATE: DESCRIPTION:
LINDSEY PLACE
NEW AMENITIESBUILDING
F.F.E. = 1312.5'
1312
1313
1313 1312
1312
1312
1312
PRF
HEDGE
FLAGPOLES
CONC.MONUMENT
ASPHALT
GARDEN
CONC.
EXIS
T. A
SPHA
LT T
O RE
MAI
N
ASPHALT
GRASS
GRASS
GRASS
CONCRETE
21
4'-0
" +
/-TO
C
OF
BLV
D A
VE.
L
RESTORE GRASS/LAWNAREA WITHIN PROJECT LIMIT LINES
PLANTING(ALTERNATE #2)
PLANTING(ALTERNATE #2)
FLUSH
FLUSH
FLUSH
PROTECT TREESDURING CONSTRUCTION
ASPHALT PAVEMENT
ASPHALT PAVEMENT
15' - 0"
1' - 6" (TYP.)
PROJECT LIMIT LINES
GRASS
CHAUTAUQUA LAKE
EXIST. PUBLIC DOCK
EXIST. LIGHTHOUSE
EXIST. SUMMER WIND DOCK
EXIST. BANDSHELL
EXIST. PAVILION
EXIST. BASKETBALL
COURT
EXIST. LUCY STATUE.
EXIST. AMY KINGMEMORIAL
EXIST. BOAT LAUNCH
EXISTING PARKING LOT
EXIST. BUILDING
EXIST. SUMMERWINDTICKET OFFICE
EXIST. RESTROOMS
EXIST. BASEBALL FIELD
EXIST. VETERANS MEMORIAL
EXIST. BLEACHER
EXIST. BLEACHER
EXIST. DUGOUT
EXIST. DUGOUTEXIST. SIGNAND PLANTINGS
EXIST. DOCK WALL
EXIST.PLAYGROUND
EXIST. 5'-0"CHAINLINKFENCE
BOULEVARD AVE
DU
NH
AM
AV
EEXIST. STO. SHED
EXIST. CONCESSION STAND
LINSEY STREET
NEW AMENITIES BUILDLING LOCATION
70' -
0" +
/-
30' - 0" +/-
SECURE FENCINGAND LOCKABLE ACCESS GATE
CONTRACTOR STAGING AREA
TEMPORARY CONSTRUCTION DRIVE (SEE 2/C-100)
STABILIZED CONSTRUCTION ENTRANCE (SEE 5/C-101)
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
2:55
:27
PM
C:\
Use
rs\t
eklu
m\D
ocum
ents
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg-
tekl
um(R
ecov
ery)
.rvt
C-101
SITE AND GRADING PLAN
TEE
RIK
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
N
SCALE: 1" = 10'-0"C-101
1 SITE / GRADING PLAN
NOT TO SCALEC-101
2 TEMPORARY SOIL STOCKPILE
NOT TO SCALEC-101
4 SILT FENCE DETAILNOT TO SCALEC-101
5 STABILIZED CONSTRUCTION ENTRANCE DETAIL
NOT TO SCALEC-101
3 ASPHALT SIDEWALK DETAIL
Revisions
NO: DATE: DESCRIPTION:
SCALE: 1" = 80'-0"C-101
6 SITE KEYPLAN
B-X
STRUCTURAL SYMBOLS LEGEND
SOIL BORING LOCATION & NUMBER
BOTTOM OF FOOTING ELEVATION
LATERAL FRAME MOMENT CONNECTION
GRAVITY MOMENT CONNECTION
ONE-WAY SPAN DIRECTION
TWO-WAY SPAN DIRECTION
STEP IN ELEVATION
RAMP DOWN
RAMP UP
STRUCTURAL SECTION
STRUCTURAL ELEVATION
DETAIL CALLOUTA101
1 SIM
1
A101
SIM
1
A101
SIM
STRUCTURAL ABBREVIATIONS
ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION
ADJ ADJACENT
ADDL ADDITIONAL
ALT ALTERNATE
AB ANCHOR BOLT
BRG BEARING
ARCH ARCHITECT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CONST JT CONSTRUCTION JOINT
CJ CONTROL JOINT
CU YD CUBIC YARD
DIA DIAMETER
DWG DRAWING
EL ELEVATION
EF EACH FACE
EQ EQUAL
EW EACH WAY
EOD EDGE OF DECK
EOS EDGE OF SLAB
EXIST EXISTING
EXP EXPANSION
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
HORIZ HORIZONTAL
GC GENERAL CONTRACTOR
HP HIGH POINT
HSS HOLLOW STRUCTURAL SECTION
JT JOINT
IF INSIDE FACE
L ANGLE
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
FS FAR SIDE
MO MASONRY OPENING
MAX MAXIMUM
MIN MINIMUM
NTS NOT TO SCALE
NIC NOT IN CONTRACT
NS
OC ON CENTER
NEAR SIDE
OF OUTSIDE FACE
PL PLATE
R RADIUS
RD ROOF DRAIN
RO ROUGH OPENING
SIM SIMILAR
SOG SLAB ON GRADE
SYMM SYMMETRICAL
STD STANDARD
T&B TOP & BOTTOM
TRANS TRANSVERSE
TYP TYPICAL
VIF VERIFY IN FIELD
UNO UNLESS NOTED OTHERWISE
WP WORK POINT
VERT VERTICAL
WD WOOD
WWF WELDED WIRE FABRIC
TOS TOP OF STEEL
TOW TOP OF WALL
TOL TOP OF LEDGEFTG FOOTING
SC SLIP CRITICAL
LW LIGHT WEIGHT
P PIER (CONCRETE)
MP MASONRY PIER
DIM DIMENSION
ES EACH SIDE
STRUCTURAL DESIGN CRITERIA
NOTE: ALL LOADS SHALL BE DETERMINED IN ACCORDANCE WITH THE "BUILDING CODE OF NEW YORK STATE" (2015)AND THE "2017 NEW YORK STATE SUPPLEMENT"
TYPE DESCRIPTION DESIGN CRITERIA
FLOOR LIVE LOAD
ROOF LIVE LOAD
SNOW LOAD
WIND LOAD
WIND LOAD
EARTHQUAKE LOAD
RESTROOMS
STORAGE
ROOF CONSTRUCTION LOAD
RISK CATEGORY / IMPORTANCE FACTOR
GROUND SNOW LOAD
SNOW EXPOSURE FACTOR
THERMAL FACTOR
FLAT ROOF SNOW LOAD
DRIFTING SNOW
RISK CATEGORY
BASIC WIND SPEED (3-SECOND GUST)
WIND EXPOSURE CATEGORY
MAXIMUM WIND PRESSURE
MAXIMUM WIND PRESSURE FOR WALLS (EFF. AREA = 10 FT2)
MAXIMUM WIND PRESSURE FOR ROOFING (EFF. AREA = 10 FT2)
RISK CATEGORY / IMPORTANCE FACTOR
DESIGN SPECTRAL RESPONSE COEFFICIENT (Sds)
DESIGN SPECTRAL RESPONSE COEFFICIENT (Sd1)
SOIL SITE CLASSIFICATION
SEISMIC DESIGN CATEGORY
BASIC SEISMIC - FORCE RESISTING SYSTEM
RESPONSE MODIFICATION FACTOR (R)
ANALYSIS PROCEDURE
DESIGN SEISMIC BASE SHEAR
60 PSF
125 PSF
20 PSF
II / 1.0
57 PSF
1.0
1.10
48 PSF
PER ASCE 7 AS REQ'D
II
115 MPH
C
PER ASCE 7
PER ASCE 7
PER ASCE 7
II / 1.0
0.223 g
0.119 g
E
B
TABLE 12.2-1 (TYPE A9)
2.0
EQUIV. LATERAL FORCE
3.3 KIPS
(MWRS)
(COMPONENT & CLADDING)
COPYRIGHT C 2019 SIRACUSE ENGINEERS, PCALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED OR COPIED IN ANY FORM BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF SIRACUSE ENGINEERS, PCREPRODUCTION OF THIS DRAWING FOR USE IN THE PRODUCTION OF SHOP DETAILS AND ERECTION DRAWINGS IS EXPRESSLY FORBIDDEN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
:42:
32
PM
Z:\L
aBel
la\J
ames
tow
n O
ffic
e\20
18-0
95 L
ucill
e B
all A
men
ities
Bui
ldin
g\D
raw
ings
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg_
S_
R18
.rvt
S-001
SYMBOLS,
ABBREVIATIONS, GENERAL
NOTES & DESIGN CRITERIA
MR
DG
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
GENERAL NOTES1 THE WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED IN ACCORDANCE WITH THE
STRUCTURAL REQUIREMENTS OF THE BUILDING CODE OF NEW YORK STATE (2015 EDITION).
2 THE STRUCTURAL COMPONENTS HAVE BEEN DESIGNED FOR THE LOADS INDICATED IN THESTRUCTURAL DESIGN CRITERIA.
3 CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS PRIOR TO THE START OF CONSTRUCTION AND THE FABRICATION OF ANYMATERIALS. NOTIFY ENGINEER OF ANY EXISTING CONDITION DISCREPANCIES.
4 THIS STRUCTURE HAS BEEN DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THECONSTRUCTION OF THE BUILDING HAS BEEN COMPLETED. THE STABILITY OF THE STRUCTUREPRIOR TO COMPLETION IS SOLEY THE RESPONSIBILITY OF THE CONTRACTOR. THISRESPONSIBILITY EXTENDS TO ALL RELATED ASPECTS OF THE CONSTRUCTION ACTIVITYINCLUDING BUT NOT LIMITED TO, ERECTION METHODS, ERECTION SEQUENCE, TEMPRORARYBRACING, SHORING, FORMS, USE OF EQUIPMENT AND SIMILAR CONSTRUCTIONPROCEDURES.
5 THE CONTRACTOR IS RESPONSIBLE FOR DESIGNING, PROVIDING AND INSTALLING ALLTEMPRORY SHORING THAT IS REQUIRED DURING CONSTRUCTION.
6 JOBSITE SAFETY AND CONSTRUCTION MEANS AND METHODS ARE SOLEY THERESPONSIBILITY OF THE CONTRACTOR. REVIEW OF THE CONSTRUCTION BY THE ENGINEERIS FOR CONFORMANCE WITH THE DESIGN ASPECTS ONLY, NOT TO REVIEW THECONTRACTOR'S PROVISIONS FOR JOB SITE SAFETY AND CONSTRUCTION PROCEDURES.LACK OF COMMENT BY THE ENGINEER IS NOT TO BE INTERPRETED AS APPROVAL.
7 LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO REQUIREMENTS OF OTHERNON-STRUCTURAL DISCIPLINES ARE SHOWN FOR REFERENCE ONLY. THESE PLANS DO NOTSHOW THE FULL SCOPE OF OPENINGS IN ROOFS, FLOORS AND WALLS. FOR SIZE ANDLOCATION OF ALL OPENINGS SEE ARCHITECTURAL AND MEP DRAWINGS. THE CONTRACTORSHALL OBTAIN FROM THE MEP AND OTHER TRADES THE FINAL APPROVED SIZE ANDLOCATION OF ALL OPENINGS AND WORK TO BE PROVIDED FOR THEIR TRADE IN ROOFS,FLOORS AND WALLS WHETHER SHOWN OR NOT ON STRUCTURAL DRAWINGS. EXCESS COSTRELATED TO VARIATION IN REQUIREMENTS OR EQUIPMENT ARE NOT TO BE BORNE BY THEOWNER.
8 IF FAULTY CONSTRUCTION PROCEDURES OR MATERIAL RESULT IN DEFECTIVE WORK THATREQUIRES ADDITIONAL ENGINEERING TIME TO DEVISE CORRECTIVE MEASURES,PROFESSIONAL FEES MAY BE CHARGED TO THE CONTRACTOR AT TEH STANDARD HOURLYRATE OF ADDITIONAL SERVICES. SUCH FEES MY BE WITHHELD FROM THE GENERALCONTRACTOR'S PAYMENT.
9 ONE BLACKLINE PRINT OF ALL ERECTION AND DETAIL SHOP DRAWINGS INDICATING THEFABRICATOR, MANUFACTURER, FINISH, LAYOUT AND ALL ACCESSORIES MUST BE SUBMITTEDTO AND BE CHECKED BY THE CONTRACTOR AND SUBCONTRACTOR AND BEAR THE CHECKER'SINITIALS BEFORE SUBMISSION TO THE ARCHITECT FOR REVIEW PRIOR TO FABRICATION.
10 THESE DRAWINGS ARE SUPPLEMENTED BY A DETAILED TECHNICAL SPECIFICATION. THENOTES SHOWN UNDER CERTAIN CATEGORIES OF WORK ARE INTENDED TO SUMMARIZE BASICREQUIREMENTS.
11 WORK SHOWN AS "TYPICAL DETAILS" APPLY THROUGHOUT THE PROJECT AS REQUIRED. WORKSHOWN AS "SECTIONS" SHALL BE CONSIDERED TO APPLY FOR THE SAME AND SIMILARCONDITIONS IN THE BUILDING.
12 SOME DETAILS OF THE WORK ARE SHOWN ON THE ARCHITECTURAL DRAWINGS. CAREFULREVIEW AND STUDY OF THE DETAILS ARE NECESSARY BEFORE THE FULL SCOPE OF THEWORK CAN BE COMPREHENDED.
13 DO NOT SCALE THE DRAWINGS.
FOUNDATION NOTES1 REFER TO DIVISION 31 OF THE PROJECT SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS OF EARTHWORK MATERIAL AND BACKFILLING.
2 REFER TO THE PROJECT "STATEMENT OF SPECIAL INSPECTIONS" FOR REQUIREDFOUNDATION TESTING AND INSPECTIONS.
3 FOUNDATIONS HAVE BEEN DESIGNED BASED ON THE GEOTECHNICAL REQUIREMENTS STATEDIN THE PROJECT GEOTECHNICAL REPORT. SEE PROJECT SPECIFICATIONS FOR REPORT.
4 ALL FOUNDATIONS SHALL BEAR ON INORGANIC, UNDISTURBED SOILS AS DESCRIBED IN THEPROJECT GEOTECHNICAL REPORT OR ON COMPACTED STRUCTURAL FILL. ACCEPTABLEBEARING STRATA IS ANTICIPATED AT THE BOTTOM OF FOOTING ELEVATIONS NOTED ONPLAN AND SHALL BE INSPECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACINGCONCRETE.
5 DO NOT PLACE CONCRETE ON FROZEN GROUND OR IN EXCAVATIONS CONTAINING FREESTANDING WATER. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL BEARINGGRADES AND SURROUNDING SOILS PRIOR TO AND AFTER FOUNDATIONS HAVE BEENPOURED.
6 BACKFILL FOUNDATION WALLS IN SUCH A MANNER TO MAINTAIN EQUAL LEVELS OF FILL ONEACH SIDE OF WALL. FILL LEVELS MAY VARY UP TO 1'-0" ON EITHER SIDE AT ANY ONE TIME.
7 CONCRETE SLABS AT THE TOP AND BOTTOM OF BASEMENT WALLS ARE ASSUMED TO BRACETHE WALLS. DO NOT BACKFILL BASEMENT WALLS UNTIL THESE SLABS HAVE BEEN POUREDAND ACHIEVE THEIR SPECIFIED 28-DAY COMPRESSIVE STRENGTH.
8 LOCATE EXISTING UNDERGROUND UTILITIES IN AREAS OF EXCAVATION WORK. PROVIDEADEQUATE MEANS OF SUPPORT AND PROTECTION DURING EARTHWORK OPERATIONS.
9 WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SUB-SURFACE PIPING, BOTTOM OFFOOTINGS SHALL BE AT LEAST 8-INCHES BELOW ELEVATION OF PIPING UNLESS OTHERWISESHOWN ON THE CONTRACT DRAWINGS.
10 COMPLY WITH ALL OSHA STANDARDS AND REGULATIONS WHEN EXCAVATING FORFOUNDATIONS.
CONCRETE NOTES1 REFER TO DIVISION 03 OF THE PROJECT SPECIFICATIONS FOR ADDITONAL CONCRETE
REQUIREMENTS.
2 REFER TO THE PROJECT "STATEMENT OF SPECIAL INSPECTIONS" FOR REQUIRED CONCRETETESTING AND INSPECTIONS.
3 ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OFACI 301 - "SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS".
4 ALL DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS, UNLESS NOTEDOTHERWISE, MUST FOLLOW THE LATEST EDITION OF THE ACI CODE AND ACI "MANUAL OFSTANDARD PRATICE FOR DETAILING REINFORCED CONCRETE STRUCTURES.
5 "WET STICKING" DOWELS AND REINFORCING INTO CONCRETE IS NOT PERMITTED. ALLDOWELS, REINFORCING AND WELDED WIRE FABRIC MUST BE SUPPORTED AND TIED IN ITSPROPER LOCATION PRIOR TO POURING CONCRETE.
6 REFER TO CHAPTER 7 OF THE LATEST EDITION OF ACI 318 FOR MINIMUM CONCRETE COVERREQUIREMENTS.
7 NO ADMIXTURES ARE PERMITTED WITHOUT THE ENGINEERS WRITTEN PERMISSION OTHERTHAN ENTRAINED AIR.
8 DO NOT USE CALCIUM CHLORIDE IN ANY CONCRETE.
9 REFER TO AND COORDINATE WITH ARCHITECTURAL AND MEP DRAWINGS FOR ALL ITEMSREQUIRED BY OTHER TRADES TO BE PLACED INTO CONCRETE PRIOR TO POURING.
10 REFER TO AND COORDINATE WITH ARCHITECTURAL AND MEP DRAWINGS FOR ALL SLABDEPRESSIONS, WALL AND SLAB OPENINGS AND FLOOR FINISHES PRIOR TO POURINGCONCRETE.
11 PLACE CONCRETE PIERS AND WALLS MONOLITHICALLY WITH WALL REINFORCINGEXTENDING THROUGH PIER.
12 DEFLECTION OF STEEL FRAMED FLOORS WILL OCCUR DURING PLACEMENT OF CONCRETEFLOOR SLABS. PROVIDE ADDITIONAL CONCRETE AS REQUIRED TO FINISH SLABS WITHINTHE SPECIFIED TOLERANCES SET FORTH IN THE PROJECT SPECIFICATIONS. ALLOW FOR ANAVERAGE OF 1/2-INCH OF ADDTIONAL CONCRETE AT EACH FLOOR SLAB POUR.
13 SAW CUT CONTROL JOINTS FOR SLABS ON GRADE WHEN CUTTING ACTION WILL NOT TEAR,ABRADE OR OTHERWISE DAMAGE THE SURFACE OF THE CONCRETE WITH AN EARLY-ENTRYDRY-CUT SAW EQUIPPED WITH DIAMOND-RIMMED BLADES. START CUTTING WITHIN 4-HOURSOF FINISHING CONCRETE AND COMPLETE CUTTING WITHIN 12-HOURS OF FINISHINGCONCRETE. JOINTS SHALL BE CUT IN PATTERN SHOWN ON PLAN.
14 A REPRESENTATIVE FROM THE FIBER REINFORCING MANUFACTURER SHALL BE PRESENT ATTHE PRE-POUR MEETING TO ADVISE ON PLACING AND FINISHING TECHNIQUES OFCONCRETE CONTAINING FIBER REINFORCING.
REINFORCED MASONRY NOTES1 REFER TO DIVISION 04 OF THE PROJECT SPECIFICATIONS FOR ADDITIONAL REINFORCED
MASONRY REQUIREMENTS.
2 REFER TO THE PROJECT "STATEMENT OF SPECIAL INSPECTIONS" FOR REQUIRED REINFORCEDMASONRY TESTING AND INSPECTIONS.
3 ALL REINFORCED MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LATESTEDITION OF ACI 530 / ASCE 5 / TMS 402 "BUILDING CODE REQUIREMENTS FOR MASONRYSTRUCTURES AND ACI 530.1 / ASCE 6 / TMS 602 "SPECIFICATIONS FOR MASONRY STRUCTURES".
4 REINFORCED MASONRY ASSEMBLAGES SHALL HAVE A MINIMUM NET AREA COMPRESSIVESTRENGTH (F'm) = 2000 PSI.
5 REINFORCED MASONRY MORTAR SHALL BE TYPE "S" MORTAR IN ACCORDANCE WITH ASTM C270.
6 BAND ALL MASONRY OPENINGS WITH (2) #5 BARS. EXTEND HORIZONTAL BARS A MINIMUM OF2'-6" BEYOND OPENINGS. EXTEND VERTICAL BARS TO FULL HEIGHT OF WALL.
7 PROVIDE HORIZONTAL JOINT REINFORCING AT 16" O.C. VERTICALLY IN ALL MASONRY WALLSUNLESS NOTED OTHERWISE ON PLAN OR IN SPECIFICATIONS.
8 ALL CELLS CONTAINING REINFORCING BARS AND / OR EMBEDMENTS SHALL BE GROUTED SOLID.
9 PROVIDE FULL MORTAR COVERAGE AT HEAD AND BED JOINTS OF FACE SHELLS AND AT ALLWEBS IN THE STARTING COURSE, MASONRY PILASTERS AND COLUMNS, SHEAR WALLS ANDADJACENT TO CELLS GROUTED SOLID.
10 REINFORCED MASONRY LINTELS HAVE BEEN DESIGNED ON THE BASIS OF ARCHING ACTION OFTHE COMPLETED WALL. LINTELS REQUIRE TEMPORARY SUPPORT UNTIL THE WALL IN COMPLETEAND THE ASSEMBLAGE HAS ACHIEVED ITS SPECIFIED NET AREA COMPRESSIVE STRENGTH (F'm).
11 ALL MASONRY WALLS MUST BE ADEQUATELY BRACED DURING CONSTRUCTION UNTIL DECK,FLOOR AND ROOF FRAMING IS COMPLETELY INSTALLED. DESIGN AND INSTALLATION OF WALLBRACING IS THE RESPONSIBILITY OF THE CONTRACTOR PERFORMING THE WORK.
12 COVER AND PROTECT THE TOP OF ALL MASONRY CONSTRUCTION TO PROTECT AGAINSTPRECIPITATION.
13 PROVIDE CONTRAL JOINTS IN WALLS AS SHOWN ON PLAN. IF NOT ON PLAN SPACE AT 25'-0" O.C.MAX. INTERRUPT HORIZONTAL BARS AND HORIZONTAL JOINT REINFORCING AT CONTROLJOINT. DO NOT LOCATE JOINT WITHIN 6'-0" OF GIRDER BEARING LOCATIONS.
14 REFER TO AND COORDINATE WITH ARCHITECTURAL AND MEP DRAWINGS FOR ALL ITEMSREQUIRED BY OTHER TRADES TO BE PLACED INTO REINFORCED MASONRY PRIOR TOCONSTRUCTING WALLS.
SPECIAL INSPECTION NOTES1 REFER TO DIVISION 01 OF THE PROJECT SPECIFICATIONS FOR THE SCHEDULE OF SPECIAL
INSPECTIONS AND ADDITIONAL SPECIAL INSPECTIONS REQUIREMENTS.
2 MATERIAL SPECIFICATION SECTIONS, THE SCHEDULE OF SPECIAL INSPECTIONS AND ALLASSOCIATED NOTES DESCRIBE THE STRUCTURAL TESTING AND INSPECTIONS REQUIRED FOR THEPROJECT. COLLECTIVELY THEY SHALL BE CONSIDERED THE STATEMENT OF SPECIALINSPECTIONS.
3 THE OWNER SHALL ENGAGE THE SERVICES OF A QUALIFIED SPECIAL INSPECTOR FOR THISPROJECT. SIRACUSE ENGINEERS, PC IS NOT THE SPECIAL INSPECTOR FOR THIS PROJECT UNLESSENGAGED BY THE OWNER UNDER A SEPARATE CONTRACT.
4 THE CONTRACTOR SHALL HOLD A PRE-CONSTRUCTION MEETING PRIOR TO THE START OFCONSTRUCTION TO DISCUSS THE REQUIRED TESTING AND INSPECTION PROCEDURES FOR THISPROJECT. THE MEETING SHALL ALSO DISCUSS NOTIFICATION AND REPORTING PROCEDURES.
5 THE CONTRACTOR SHALL NOTIFY THE SPECIAL INSPECTOR AND TESTING AGENCY AT LEAST 24HOURS IN ADVANCE OF A REQUIRED INSPECTION OR TEST. UN-INSPECTED WORK THAT REQUIRESINSPECTION OR TESTING MAY BE REJECTED SOLELY ON THAT BASIS.
6 THE SPECIAL INSPECTOR AND/OR TESTING AGENCY SHALL IMMEDIATELY NOTIFY THECONTRACTOR OF DEFICIENT WORK THAT REQUIRES CORRECTIVE ACTION. INSPECTIONREPORTS FOR THIS WORK SHALL NOTE WHEN AND HOW THE DEFICIENT WORK WAS CORRECTED.WORK IMMEDIATELY CORRECTED WITH SPECIAL INSPECTOR OR TESTING AGENCY PRESENT ANDRE-INSPECTED OR TESTED NEED NOT BE IDENTIFIED AS NON-CONFORMING WORK.
7 DEFICIENT WORK, NOT IMMEDIATELY CORRECTED WHILE SPECIAL INSPECTOR OR TESTINGAGENCY ARE ON SITE, SHALL BE REPORTED TO THE ENGINEER OF RECORD AND CODEENFORCEMENT OFFICIAL WITHIN 24 HOURS. A REPORT OF NON-CONFORMANCE SHALL BE ISSUEDFOR THIS WORK.
8 THE CONTRACTOR SHALL COOPERATE WITH THE SPECIAL INSPECTOR AND TESTING AGENCYINCLUDING SAFE ACCESS TO THE WORK AREAS SO THAT TESTING AND INSPECTIONS CAN BEPERFORMED IN A TIMELY MANNER OR UNDUE DELAY TO THE PROJECT.
9 THE SPECIAL INSPECTIONS REQUIREMENTS OF THIS PROJECT IN NO WAY RELIEVE THECONTRACTOR OF HIS/HER OBLIGATION TO PERFORM WORK IN ACCORDANCE WITH THEREQUIREMENTS OF THE CONTRACT DOCUMENTS OR FROM IMPLEMENTING A EFFECTIVE QUALITYCONTROL PROGRAM.
10 EACH TESTING AGENCY SHALL SUBMIT, STAMP AND SIGN AN AGENT'S FINAL REPORT TO THESPECIAL INSPECTOR FOR ATTACHMENT TO THE SPECIAL INSPECTOR'S FINAL REPORT. THE FINALREPORT SHALL BE STAMPED AND SIGNED BY THE SPECIAL INSPECTOR AND SUBMITTED TO THECODE ENFORCEMENT OFFICIAL AND OWNER PRIOR TO THE ISSUANCE OF A CERTIFICATE OF USEAND OCCUPANCY.
WOOD NOTES1 REFER TO DIVISION 06 OF THE PROJECT SPECIFICATION FOR ADDITIONAL WOOD
REQUIREMENTS.
2 REFER TO PROJECT "STATEMENT OF SPECIAL INSPECTIONS" FOR REQUIRED WOODINSPECTIONS.
3 ALL WOOD CONSTRUCTION SHALL CONFORM TO AWC NDS - NATIONAL DESIGNSPECIFICATION FOR WOOD CONSTRUCTION AND ITS SUPPLEMENTS AND APA PANEL DESIGNSPECIFICATION.
4 STORAGE OF ALL LUMBER AND TIMBER ON SITE SHALL BE KEPT OFF GROUND, UNDER COVERAND PROTECTED FROM DAMAGE.
5 ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THEMINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE.
6 MINIMUM NUMBER AND SIZE OF FASTENERS CONNECTING WOOD MEMBERS SHALL CONFORMTO TABLE 2304.10.1 IN THE INTERNATIONAL BUILDING CODE.
7 ALL NAILS FOR STRUCTURAL WORK SHALL BE COMMON WIRE NAILS. HOLES SHALL BEPRE-DRILLED WHERE NECESSARY TO PREVENT SPLITTING.
8 STUD BEARING WALLS, SHEAR WALLS AND ROOF AND FLOOR DECKS SHALL BE FRAMED WITHTHE MEMBER SIZES AND/OR TYPES AT THE SPACINGS SHOWN ON PLAN. THE CONTRACTORSHALL COORDINATE LOCATIONS OF ALL PLUMBING PIPING, HVAC DUCTING AND RECESSEDLIGHTING FIXTURES, ETC PRIOR TO LAYOUT TO MINIMIZE INTERFERENCE THAT MAYREQUIRE THE ALTERING OR STRENGTHENING OF THE INSTALLED FRAMING.
9 ROOF AND FLOOR FRAMING MEMBERS SHALL BE POSITIONED SO THEY BEAR DIRECTLYOVER THE WALL STUDS WITH AN OFFSET TOLERANCE OF NO MORE THAN 1 INCH.
10 FLUSH FRAMED CONNECTIONS SHALL BE MADE WITH PREFABRICATED GALVANIZED STEELHANGERS MADE BY SIMPSON STRONG-TIE, CO. INC. OR APPROVED EQUIVALENT OF WIDTHAND DEPTH APPROPRIATE FOR THE SUPPORTED MEMBERS. INSTALL WITH THE TYPE ANDQUANTITY OF FASTENERS RECOMMENDED BY THE MANUFACTURER.
11 PREFABRICATED STEEL HANGERS USED IN CONTACT WITH PRESERVATIVEPRESSURE-TREATED OR FIRE RETARDANT-TREATED WOOD SHALL BE HOT-DIP GALVANIZEDOR STAINLESS STEEL. FASTENERS IN CONTACT WITH PRESERVATIVE PRESSURE-TREATED ORFIRE RETARDANT-TREATED WOOD SHALL BE HOT-DIP GALVANIZED OR STAINLESS STEEL. DONOT MIX STAINLESS STEEL AND GALVANIZED FASTENERS AND CONNECTORS.
12 ENGINEERED LUMBER MEMBERS SHALL BE MANUFACTURED UNDER A PROCESS BY THENATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP NOTING THE NAME ANDPLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NATIONAL RESEARCH BOARDNUMBER, AND THE QUALITY CONTROL AGENCY.
13 ALL FLOOR AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAINPERPENDICULAR TO THE SUPPORTS.
14 ALL SHEATHING PANELS SHALL BE INSTALLED WITH END JOINTS STAGGERED UNLESS NOTEDOTHERWISE ON THE DRAWINGS.
15 STRUCTURAL WOOD MEMBERS MAY NOT BE BORED OR NOTCHED WITHOUT WRITTENPERMISSION FROM THE ENGINEER OR AS INDICATED ON THE CONTRACT DRAWINGS.
16 STRUCTURAL WOOD FRAMING USED IN EXTERIOR APPLICATIONS OR IN CONTACT WITHCONCRETE OR MASONRY SHALL BE SOUTHERN YELLOW PINE NO. 2 OR BETTER,PRESERVATIVE PRESSURE TREATED WOOD WITH A RETENTION APPROPRIATE FOR END USE.
Revisions
NO: DATE: DESCRIPTION:
04/26/2019
NOTES:
1.) TOP BARS ARE THOSE WHICH ARE ORIENTED HORIZONTALLY AND HAVE MORE THAN 12" OF CONCRETE BELOW THE BAR.
2.) EMBEDMENT AND LAP SPLICE LENGTHS SHOWN ARE APPLICABLE TO ASTM A615 GR. 60 REINFORCING BARS. FOR GR. 75 REINFORCING BARS, MULTIPLY LENGTHS BY 1.25.
3.) TABULATED VALUES ARE BASED ON CONCRETE COVER CONTROLLING. FOR BARS WITH CENTER-TO-CENTER SPACING LESS THAN 1.0Db (BAR DIAMETER) PLUS TWICE THE CONCRETE COVER, NOTIFY THE ENGINEER.
4.) WHERE CONCRETE DEPTH PRECLUDES FULL EMBEDMENT, PROVIDE 90 DEGREE HOOK.
5.) PROVIDE CONCRETE PROTECTION FOR REINFORCEMENT AS DESCRIBED IN ACI 318, CHAPTER 7.
6.) TABULATED VALUES ARE BASED ON NORMAL WEIGHT AGGREGATE. FOR LIGHTWEIGHT AGGREGATE, MULTIPLY LENGTHS BY 1.33.
REINFORCING BAR EMBEDMENT / LAP SPLICE SCHEDULE
BAR SIZE
CONCRETE COVER < 1 1/2"
TOP BARS OTHER BARS
3,000 psi 4,000 psi 3,000 psi 4,000 psi 3,000 psi 4,000 psi 3,000 psi 4,000 psi
#3
#4
#5
#6
#7
#8
13"
22"
32"
43"
69"
86"
CONCRETE COVER > 1 1/2"
TOP BARS OTHER BARS
EMBED. LAP EMBED. LAP EMBED. LAP EMBED. LAP EMBED. LAP EMBED. LAP EMBED. LAP EMBED. LAP
17"
28"
41"
56"
90"
111"
12"
17"
24"
33"
53"
66"
13"
22"
32"
43"
69"
86"
12"
19"
28"
37"
60"
74"
15"
24"
36"
48"
78"
96"
12"
15"
21"
29"
46"
57"
12"
19"
28"
37"
60"
64"
13"
17"
22"
26"
43"
54"
17"
23"
28"
34"
55"
70"
12"
13"
17"
20"
33"
41"
13"
17"
22"
26"
43"
54"
12"
15"
19"
22"
37"
47"
15"
20"
24"
29"
48"
60"
12"
12"
15"
17"
28"
36"
12"
15"
19"
22"
37"
47"
#9
#10
104"
125"
135"
162"
80"
96"
104"
125"
90"
108"
117"
140"
69"
83"
90"
108"
66"
81"
86"
105"
51"
62"
66"
81"
57"
70"
74"
91"
44"
54"
57"
70"
CONCRETE SLAB, SEE PLAN
PROVIDE 1" CLEAR COVER WHEREMESH IS REQ'D. (SEE PLAN). SET MESH ON BOLSTERS/CHAIRS TO MAINTAINPOSITION
15 MIL CLASS A STEGO WRAPVAPOR BARRIER OR APPROVEDEQUAL
FULLY COMPACTED STRUCTURAL FILL WHERE REQUIRED TO RAISE GRADE OVER EXCAVATED AREAS.
PROOF-ROLLED EXIST. GRADESTABILIZATION SEPARATION GEOTEXTILE FABRIC
CUT LINE
6" MIN. COMPACTED NYSDOTITEM 304.12 - TYPE 2 SUBBASESTONE.
2' - 6" 2' - 0" 2' - 6"
"d"
1/8"
APPLY SEALANT FLUSH WITH TOP OF CONCRETE SLAB
PROVIDE 1" CLEAR COVER WHERE MESH ISREQ'D (SEE PLAN). SET MESH ON BOLSTERS/CHAIRS TO MAINTAIN POSITION
SAWCUT
CONCRETE SLAB, SEE PLAN
SEE TYPICAL SLAB ON GRADE DETAIL
CONCRETE SLAB, SEE PLAN
PROVIDE 1" CLEAR COVER WHERE MESH ISREQ'D (SEE PLAN). SET MESH ON BOLSTERS/CHAIRS TO MAINTAIN POSITION
2x4 CONT.KEYWAY
to 8
"THICKEN S
LAB
SEE TYPICAL SLAB ON GRADE DETAIL.
CONTRACTION JOINT
CONSTRUCTION JOINT
1/4 d
SEE P
LAN
CO
NC. SLAB,
FF ELEV. +0'-0"
UNEXCAVATED MATERIAL
BACKFILLSEE TYPICAL SLAB ON GRADE DETAIL
H/2H/2
STRUCTURAL FILL
H =
2'-0"
EXIST. FILL
UNDISTURBED, SUITABLE BEARING GRADE. SEE PROJECT GEOTECH REPORTFOR ADD'L INFORMATION
INTERIOR LINTEL SCHEDULESCHEDULE APPLIES TO ALL OPENINGS REQ'D IN NON-LOAD BEARING
WALLS INCLUDING OPENINGS REQUIRED FOR MECHANICAL PENETRATIONS
THICKNESS OF MASONRY WALL
CLEAR OPENING SIZE OF LINTEL
4" MASONRY
UP TO 9'-0"PL 3/8 x 3
PL 3/8 x 45/16 4@12
8" @ ENDS
9'-0" TO 12'-0"PL 3/8 x 3
PL 1/2 x 65/16 4@12
12" @ ENDS
6" MASONRY
UP TO 9'-0"PL 3/8 x 5
PL 3/8 x 65/16 4@12
8" @ ENDS
9'-0" TO 12'-0"PL 3/8 x 5
PL 1/2 x 85/16 4@12
12" @ ENDS
UP TO 5'-0" 2L's 4 x 3 1/2 x 5/16
5'-0" TO 7'-6" 2L's 5 x 3 1/2 x 5/16
7'-6" TO 9'-0" 2L's 6 x 3 1/2 x 5/16
8" MASONRY
3L's 4 x 3 x 5/16
3L's 5 x 3 x 5/16
3L's 6 x 3 x 5/16
10" MASONRY
3L's 4 x 3 1/2 x 5/16
3L's 5 x 3 1/2 x 5/16
3L's 6 x 3 1/2 x 5/16
12" MASONRY
UP TO 5'-0"
5'-0" TO 7'-6"
7'-6" TO 9'-0"
UP TO 5'-0"
5'-0" TO 7'-6"
7'-6" TO 9'-0"
LINTELS TO BEAR 8" MIN. AT EACH END.
NOTE: LINTELS FOR OPENINGS EXCEEDING 6'-0" TO BE SHORED AT1/3 POINTS FOR 72 HOURS AFTER SETTING MASONRY.
EQ EQ
REBAR POSITIONER
DIA. LAP
40 B
AR
DIA. LAP
40 B
AR
1-#5 AT 32" o.c.
HORIZ. JOINT REINF. AT 16" o.c.
HOLD GROUT DOWN 1" AT TOP OF LIFT
DOWELS TO MATCH VERT. REINF.
BOND BEAM WITH(2) #5 CONT.
BOND BEAM WITH(2) #5 CONT.
FOOTING - SEE PLAN & SECTIONS
3' -
4"
4' -
8" M
AX, TYP.
FIRST FLOOR
GRO
UT R
EINFO
RCED C
ELLS S
OLID
REINFO
RCED S
PLIT F
ACE C
MU
GRO
UT A
LL C
ELLS S
OLID
REINFO
RCED C
MU
DIA. LAP
40 B
AR
GROUT BOND BEAM SOLID
(3) #5 VERT. & DWLS.
2 #5 CONT.BOND BEAM W/
#5 CORNER BAR W/ 2'-0" LEGS
SEE PLAN
6" REINFORCED CMU
SEE P
LAN
6" REINFO
RCED C
MU
CMU - SEE PLAN
8" REINFORCED
#4 VERT. @ 16" O.C. MAX
#5 CORNER BAR W/ 2'-0" LEGS AT BOND BEAM ELEVATIONS
EXTEND BAR FROM BOND BEAM
5"
2-#5
OPENING
CMU WALL - SEE PLAN FOR SIZE
FILL W/ GROUT (FULL HEIGHT OF WALL)
MP-1
NOTES:
1. MASONRY PIERS SHALL EXTEND DOWN TO FOUNDATIONS UNLESS INTERRUPTED BY LINTEL.
2. WHERE INTERRUPTED BY LINTEL, FIELD WELD VERT. BAR TO TOP FLANGE ON LINTEL.
GROUT SOLID TOUNDERSIDE OF LINTEL
5"
CMU WALL - SEE PLAN FOR SIZE
FILL W/ GROUT (FULL HEIGHT OF WALL)
MP-2
2-#5
COPYRIGHT C 2019 SIRACUSE ENGINEERS, PCALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED OR COPIED IN ANY FORM BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF SIRACUSE ENGINEERS, PCREPRODUCTION OF THIS DRAWING FOR USE IN THE PRODUCTION OF SHOP DETAILS AND ERECTION DRAWINGS IS EXPRESSLY FORBIDDEN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
:42:
33
PM
Z:\L
aBel
la\J
ames
tow
n O
ffic
e\20
18-0
95 L
ucill
e B
all A
men
ities
Bui
ldin
g\D
raw
ings
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg_
S_
R18
.rvt
S-002
TYPICAL CONCRETE &
MASONRY DETAILS
MR
DG
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
TYPICAL SLAB ON GRADE DETAIL
TYPICAL CONTROL JOINT DETAILS
TYPICAL EXCAVATION DETAIL
TYPICAL 8" REINFORCED MASONRY WALL DETAILS
TYPICAL REINF. MASONRY CORNER DETAILS TYPICAL MASONRY PILASTER DETAIL
Revisions
NO: DATE: DESCRIPTION:
04/26/2019
1. SEE STRUCTURAL DESIGN CRITERIA ON DWG S-001 FOR ADDITIONAL LOADING INFORMATION
2. TRUSSES TO BE DESIGNED FOR WIND & SEISMIC LOAD IN ACCORDANCE WITH"BUILDING CODE OF NEW YORK STATE" (2015).
3. TRUSSES MUST BE DESIGNED AND BUILT BY A REPUTABLE TRUSS MANUFACTURER.ALL TRUSS DESIGN AND DETAILS MUST BE STAMPED AND SIGNED BY A NEW YORKSTATE PROFESSIONAL ENGINEER.
4. TRUSS COMPONENTS TO BE A MINIMUM OF 2x6 FOR TOP & BOTTOM CHORDS, AND2x4 FOR WEB MEMBERS.
5. STRUCTURAL CALCULATIONS:
SUBMIT STRUCTURAL CALCULATIONS PREPARED BY THE MANUFACTURER FORAPPROVAL BY THE PROJECT ENGINEER. CALCULATIONS SHALL INCLUDE, BUT ARE NOT LIMITED TO:
A. DESCRIPTION OF DESIGN CRITERIA.
B. ENGINEERING ANALYSIS DEPICTING STRESS AND DEFLECTION (STIFFNESS) REQUIREMENTS FOR EACH FRAMING APPLICATION.
C. SELECTION OF FRAMING COMPONENTS AND ACCESSORIES.
D. VERIFICATION OF ATTACHMENTS TO STRUCTURE AND FOR ADJACENTFRAMING COMPONENTS.
E. FASTENERS: PROVIDE NUTS, BOLTS, WASHERS, SCREWS, AND OTHER FASTENERS WITH CORROSION-RESISTANT PLATED FINISH.
6. TRUSS MANUFACTURER TO SUPPLY BRACING REQUIREMENTS FOR TRUSSES.MATERIAL AND ATTACHMENT BY GENERAL CONTRACTOR.
7. TRUSS DESIGN SHALL CONFORM TO THE REQUIREMENTS OF THE A.I.T.C.
8. DEFLECTION SHALL NOT EXCEED 1/240TH SPAN FOR TOTAL LOAD & 1/360TH SPANFOR LIVE LOAD.
9. INSTALL ALL TRUSSES AS PER MANUFACTURERS INSTRUCTIONS.
10. DO NOT INSTALL ROOF TRUSSES UNTIL AFTER STUD WALLS ARE FULLY BRACEDAND STABILIZED.
WOOD TRUSS - GENERAL NOTES
MINIMUM TRUSS LOADING
LL = 10 PSFDL = 10 PSF
LL = 48 PSFDL = 10 PSF
LL = 57 PSFDL = 10 PSF
4' - 0" MIN. 4' - 0" MIN.
2x6 PLATESELEVATION
3" 3" TYP.(2) 2x6(8) 16d NAILS, EACHSIDE OF JOINT
PLAN - NAILING STAGGER
TYPICAL - ALL DOUBLE PLATE CONDITIONS
1/8" GAP
APA RATED PLYWD.SHEATHING
SIMPSON 'PSCL' PANEL SHEATHINGCLIPS EQUALLY SPACE BETWEENEACH TRUSS/SUPPORT
STAGGER PLYWOOD JOINTS
EDGE NAIL @ ROOF PERIMETER
SIMPSON 'PSCL' PANEL SHEATHINGCLIPS EQUALLY SPACED BETWEENEACH TRUSS/RAFTER
LONG DIMENSION OF PLYWOODSHEATHING PANEL TO RUNPERPENDICULAR TO TURSSES
EDGE NAIL @ PERIMETEROF PLYWOOD PANEL
FIELD NAIL @ ALL INTERMEDIATETRUSSES/RAFTERS
NOTES:
1. MINIMUM PLYWOOD SHEET SIZE SHALL BE 2'-8" x 4'-0".
2. MINIMUM 3/8" NAILING EDGE DISTANCE.
PREFAB. WOODTRUSSES
SIMPSON 'DTC' GALV. ROOFTRUSS CLIP @ 4'-0" O.C.
1" G
AP
NON-BEARING CMU PARTITION
PERPENDICULAR TO TRUSS
NON-BEARING CMU PARTITION
PREFAB. WOOD TRUSSES, TYP.
2x6 VERT. BLOCKING 4'-0" O.C.W/ (2) 16d EA. END, EA. SIDE
SIMPSON 'DTC' GALV. ROOFTRUSS CLIP @ 4'-0" O.C.
PARALLEL TO TRUSS
1" G
AP
GROUT SOLID GROUT SOLID
COPYRIGHT C 2019 SIRACUSE ENGINEERS, PCALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED OR COPIED IN ANY FORM BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF SIRACUSE ENGINEERS, PCREPRODUCTION OF THIS DRAWING FOR USE IN THE PRODUCTION OF SHOP DETAILS AND ERECTION DRAWINGS IS EXPRESSLY FORBIDDEN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
:42:
34
PM
Z:\L
aBel
la\J
ames
tow
n O
ffic
e\20
18-0
95 L
ucill
e B
all A
men
ities
Bui
ldin
g\D
raw
ings
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg_
S_
R18
.rvt
S-003
TYPICAL WOOD FRAMING
DETAILS
MR
DG
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
TYPICAL PLATE LAP DETAIL
TYPICAL ROOF SHEATHING EDGE SUPPORTTYPICAL ROOF SHEATHING FASTENING DETAIL
TYPICAL BRACING AT NON-LOAD BEARING PARITION DETAIL
Revisions
NO: DATE: DESCRIPTION:
04/26/2019
CJ CJCJ
CJ
CJ
CJ
CJ
CJ
CJ
1
S-201
5' - 4"
12' -
0"
3
S-2011
S-201
1
S-201
3
S-201
1
S-201
SLO
PE
SLO
PE
SLO
PE
SLO
PE
6' - 4"
4"4"
1' - 8 1/2"
10' -
11 3
/8"
3' -
5 1
/4"
10' -
11 3
/8"
SLOPE SLOPE
SLOPE SLOPE
4" EXTERIOR SLAB ON GRADE W/ 6X6 W2.1XW2.1 WWF
4" EXTERIOR SLAB ON GRADE W/ 6X6 W2.1XW2.1 WWF
FD
FD
8" 3' - 4" 1' - 4"
2
S-201
41' - 4"
2' - 0"33' - 0"
25' -
4"
8" 3' - 4" 1' - 4"
13' - 6"
TYP. @ CORNERS6
' -
8"
6' -
8"
COPYRIGHT C 2019 SIRACUSE ENGINEERS, PCALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED OR COPIED IN ANY FORM BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF SIRACUSE ENGINEERS, PCREPRODUCTION OF THIS DRAWING FOR USE IN THE PRODUCTION OF SHOP DETAILS AND ERECTION DRAWINGS IS EXPRESSLY FORBIDDEN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
:42:
35
PM
Z:\L
aBel
la\J
ames
tow
n O
ffic
e\20
18-0
95 L
ucill
e B
all A
men
ities
Bui
ldin
g\D
raw
ings
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg_
S_
R18
.rvt
S-101
FOUNDATION / FIRST
FLOOR PLAN
MR
DG
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
NOTES:
1. FLOOR CONSTRUCTION SHALL BE 4" CONCRETE SLAB ON GRADE W/ SIKAFIBER FORCE 950 BLEND FIBROUS REINFORCING (5#/CU. YD.) SEE TYPICAL SLAB BASE DETAIL.
2. FINISH FIRST FLOOR ELEVATION SHALL BE 0'-0" (REF. ACTUAL ELEV. = 1312.5').
3. CONSTRUCTION & CONTROL JOINTS ARE NOTED THUS, C.J., ON PLAN. SEE TYPICAL DETAILS.
4. FOUNDATION WALLS SHALL BE 8" REINFORCED CMU WALLS GROUTED SOLID. SEE TYPICAL DETAIL & SECTIONS FOR ADDITIONAL INFORMATION.
5 FOUNDATIONS TO BEAR ON SUITABLE, RELATIVELY UNDISTURBED, INDIGENOUS SOIL SUBGRADE OR COMPACTED STRUCTURAL FILL. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL INFORMATION.
6. BOTTOM OF FOOTING ELEVATIONS SHALL BE (-4'-4") FROM FINISH FIRST FLOOR ELEVATION (0'-0") UNLESS NOTED OTHERWISE ON PLAN, SHOWN (-X'-X") FROM FINISH FIRST FLOOR ELEVATION (0'-0").
7. SEE DRAWINGS S001 - S003 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & TYPICAL DETAILS TO BE INCORPORATED INTO THE WORK.
SCALE:1/4" = 1'-0"S-101
1 FOUNDATION / FIRST FLOOR PLANNORTH
Revisions
NO: DATE: DESCRIPTION:
04/26/2019
6
S-201 RIDGE
@ 1
6" O
.C.
PRE-F
AB W
OO
D T
RUS
SES
4
S-201
5
S-201
5
S-201
L-1 L-1
L-1 L-1
L-1
L-1
L-2
MP-1 TYP. AT OPENING JAMBS UNLESS NOTEDOTHERWISE
3' -
5 5
/8"
3' - 5 5/8" 1' - 9 5/8"
1' -
9 5
/8"
1' -
9 5
/8"
1' - 9 5/8"3' - 5 5/8"
3' -
5 5
/8"
LO
CATIO
N &
CANTILEVER T
O F
RO
NT E
DGE
TRUS
S S
HALL B
EAR O
N R
ECESSED W
ALL
6" REINFORCED MASONRY TYP. @ CORNERS - SEE TYPICAL DETAIL ON S-002
DECORATIVE ARCHED WOOD BEAM - SEE ARCH. DRAWINGS
L-1
MP-2MP-2
L-1
MP-2MP-2
L-1
MP-2
LINTEL SCHEDULE
MARK SIZE
L-1 (2) L4 x 3 1/2 x 5/16
L-2 (2) L5 x 3 1/2 x 5/16
COPYRIGHT C 2019 SIRACUSE ENGINEERS, PCALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED OR COPIED IN ANY FORM BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF SIRACUSE ENGINEERS, PCREPRODUCTION OF THIS DRAWING FOR USE IN THE PRODUCTION OF SHOP DETAILS AND ERECTION DRAWINGS IS EXPRESSLY FORBIDDEN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
:42:
35
PM
Z:\L
aBel
la\J
ames
tow
n O
ffic
e\20
18-0
95 L
ucill
e B
all A
men
ities
Bui
ldin
g\D
raw
ings
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg_
S_
R18
.rvt
S-102
ROOF FRAMING PLAN
MR
DG
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
NORTH
SCALE:1/4" = 1'-0"S-102
1 ROOF FRAMING PLAN
NOTES:
1. ROOF CONSTRUCTION SHALL BE 5/8" APA RATED PLYWOOD SHEATHING WITH GALV. PANEL CLIPS. FASTEN WITH 10d COMMON NAILS @ 6" O.C. AT PANEL EDGES AND @ 12" O.C. AT INTERMEDIATE SUPPORTS.
2. TRUSS BEARING ELEVATION TO BE AS SHOWN ON SECTIONS. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF PROFILEAND SLOPE.
3. EXTERIOR MASONRY WALLS SHALL BE 8" REINFORCED SPLIT FACED CMU UNLESS NOTED OTHERWISE ON PLAN. SEE TYPICAL WALL DETAIL & SECTIONS FOR ADDITIONAL INFORMATION.
4 EXTERIOR WALL SHEATHING ABOVE MASONRY WALLS TO BE 1/2" APA RATED STRUCTURAL I PLYWOOD SHEATHING. FASTEN WITH 8d COMMON NAILS @ 6" O.C. AT PANEL EDGES AND @ 12" O.C. AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES TO BE BACKED WITH 2x WOOD BLOCKING, TYPICAL.
5. SEE DRAWINGS S001 - S003 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & TYPICAL DETAILS TO BE INCORPORATED INTO THE WORK.
Revisions
NO: DATE: DESCRIPTION:
04/26/2019
REINFORCED SPLIT FACE CMU BRG. WALL SEE PLAN & TYPICAL DETAIL
SIDEWALK, SEE CIVIL/SITE DWGS.
FLOOR CONSTR.,SEE PLAN
JT. FILLER MAT'L (TYP)
SEE TYPICAL SLABON GRADE DETAIL
2'-0" X 1'-0" THICKCONC. FTG. W/ (3) #5 CONT.SEE PLAN
FOR ELEV.
FOUNDATION UNDERCUTREFER TO TYPICAL EXCAVATION
DETAILS & GEOTECHNICAL REPORT
REINFORCED CMUFOUNDATION WALL SEE PLAN & TYPICAL DETAIL
BENT DWLS TO MATCHVERT. WALL REINFORCINGALT. DIRECTION OF HORIZ. LEG
CELLS S
OLID
GRO
UT A
LL
T.O. BOND BEAM+10'-0"
2X CONT.
ROOF CONSTR.,SEE PLAN
12
4
COORDINATE TRUSSPROFILE W/ ARCH. DWGS.
8" CMU BOND BEAMW/ (2) #5 CONT.GROUTED SOLID
REINFORCED SPLIT FACE CMU BRG. WALLSEE TYPICAL DETAIL
PRE-FAB WOODTRUSS, SEE PLAN
SIMPSON 'H2.5T' TIE (TYP)
(2) 2x8 P.T. WD. PLATE W/1/2" DIA. ANCHOR @ 24" O.C.
T.O. BOND BEAM+10'-0"
8" CMU BOND BEAMW/ (2) #5 CONT.GROUTED SOLID
REINFORCED SPLITFACE CMU BRG. WALLSEE TYPICAL DETAIL
(2) 2x8 P.T. WD. PLATE W/1/2" DIA. ANCHOR @ 24" O.C.
2X6 WD. BLKG. @ 16" O.C.
2x CONT.
ROOF CONSTR.,SEE PLAN
2X8 WD. STUD WALL W/ 1/2"PLYWOOD SHEATHING (STUDS @ 16" O.C.)
(2) 2X8 WD. TOP PL. SPLICE ONLY AT VERT. STUD - STAGGERED
2X6 X 10'-0" LG. WD. BRACE@ 4'-0" O.C., CONN. TO BOTT.CHORD OF TRUSSES
PRE-FAB WD. TRUSS, SEE PLAN
DOOR OPENING REFER TO ARCH. DWGS.
EXTERIOR CONC. -SEE PLAN
FLOOR CONSTR.,SEE PLAN
JT. FILLER MAT'L (TYP)
SEE TYPICAL SLABON GRADE DETAIL
2'-0" X 1'-0" THICKCONC. FTG. W/ (3) #5 CONT.SEE PLAN
FOR ELEV.
FOUNDATION UNDERCUTREFER TO TYPICAL EXCAVATION
DETAILS & GEOTECHNICAL REPORT
REINFORCED CMUFOUNDATION WALL
BENT DWLS TO MATCHVERT. WALL REINFORCING
#4 DWLS @ 16" O.C.
CELLS S
OLID
GRO
UT A
LL
1' - 0"
8"
GREASE THIS END6" EMBED &
#5 DWLS @ 12" O.C.
REINFORCED SPLIT FACE CMU BRG. WALL SEE PLAN & TYPICAL DETAIL
GRADE - SEE CIVIL/SITE DWGS
FLOOR CONSTR.,SEE PLAN
JT. FILLER MAT'L (TYP)
SEE TYPICAL SLABON GRADE DETAIL
2'-0" X 1'-0" THICKCONC. FTG. W/ (3) #5 CONT.SEE PLAN
FOR ELEV.
FOUNDATION UNDERCUTREFER TO TYPICAL EXCAVATION
DETAILS & GEOTECHNICAL REPORT
REINFORCED CMUFOUNDATION WALL SEE PLAN & TYPICAL DETAIL
BENT DWLS TO MATCHVERT. WALL REINFORCINGALT. DIRECTION OF HORIZ. LEG
STONE VENEER - SEE ARCH.
T.O. BOND BEAM+10'-0"
REINFORCED SPLIT FACE CMU BRG. WALLSEE TYPICAL DETAIL
PRE-FAB WOODTRUSS, SEE PLAN
SIMPSON 'H2.5T' TIE (TYP EA. SIDE)
(2) 2x8 P.T. WD. PLATE W/1/2" DIA. ANCHOR @ 24" O.C.
2X CONT.
ROOF CONSTR.,SEE PLAN
12
4
COORDINATE TRUSSPROFILE W/ ARCH. DWGS.
8" CMU BOND BEAMW/ (2) #5 CONT.GROUTED SOLID
1/2" PLYWOOD SHEATING
TRUSSES CANTILEVER
DECORATIVE WOOD ARCHEDBEAM - SEE ARCH. DWGS.
COPYRIGHT C 2019 SIRACUSE ENGINEERS, PCALL RIGHTS RESERVED. NO PART OF THIS DRAWING MAY BE REPRODUCED OR COPIED IN ANY FORM BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF SIRACUSE ENGINEERS, PCREPRODUCTION OF THIS DRAWING FOR USE IN THE PRODUCTION OF SHOP DETAILS AND ERECTION DRAWINGS IS EXPRESSLY FORBIDDEN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
:42:
36
PM
Z:\L
aBel
la\J
ames
tow
n O
ffic
e\20
18-0
95 L
ucill
e B
all A
men
ities
Bui
ldin
g\D
raw
ings
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg_
S_
R18
.rvt
S-201
SECTIONS
MR
DG
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORONSCALE:
SECTION3/4" = 1'-0" S-201
1
SCALE:
SECTION3/4" = 1'-0" S-201
4
SCALE:
SECTION3/4" = 1'-0" S-201
5
SCALE:
SECTION3/4" = 1'-0" S-201
3SCALE:
SECTION3/4" = 1'-0" S-201
2
SCALE:
SECTION3/4" = 1'-0" S-201
6
Revisions
NO: DATE: DESCRIPTION:
04/26/2019
A-201 1
A-201
2
A-201
4
A-2013
1
A-301
___________1
A-301
___________
25' -
4"
6' -
8"
6' -
8"
12' -
0"
46 SF
SURVEILLANCEEQUIPMENT
03A
254 SF
STORAGE03
237 SF
WOMENS01
252 SF
MENS02
PLUMBING CHASE03B
WH
A5
A5
A15
A14
A4
A4
A10
A7
A7
A7 A7
A6 A6
A6 A6
A5
A11A11
A11A11
A21
A22
A14
A22 A21
A7
A3
A3
FD.
FD.
FD.
01
02
03
03A
03B
A16
A16
A13
A13
A12
A18
A12
A18
A12
A17
A19
A13 A13
A20
A17
A19
A20
A14
A13
A20
A20
A13
41' - 4"
3' - 8" 5' - 0"
(M.O.)
3' - 4" 6' - 8"
(M.O.)
3' - 4"
(M.O.)
6' - 4" 2' - 0"
5' - 4" 5' - 4" 16' - 2"4"
12' - 6"
10
' - 3
"
5' - 8" 8' - 1"
11' - 0"
2' -
10"
10
' - 3
"
8' - 8"
(M.O.)
3' - 4" 6' - 8"
(M.O.)
3' - 4" 19' - 4"
20' - 3"
FD.
1
3
3
3
4
4
1
1
A-102
6
5
A-102
4
A-102
6
A-102
3
A14
A2
A23
A1
12
22
2
W1 W1
W1 W1
A10A10
3
A8
3
3
43
5' - 4"
5' -
0" (
CLR
.)
5' -
0" (
CLR
.)
1
1
A3
A24
A24
A24
A3
3' -
6"
2' - 6"
A26
A25H
.O.D
.
2"
2" W.O.D.2"
DOOR FRAMEDOOR ELEVATION
W.O.D.
H.O
.D.
F-1D-1
W.O.D. = WIDTH OF DOORH.O.D. = HEIGHT OF DOOR
WINDOW ELEVATION
W-1
3' -
4"
(M.O
.)
4' -
8"
(M.O.)
3' - 4"
4"
2" W.O.D.2"
F-2
H.O
.D.
HM FRAME (PT.)GROUT SOLID
6"x4" LLU ANGLE(-SEE STRUCT)
4" REINF. CMU WALL(SEE STRUCT. DWGS.)
DOOR AS SCHEDULED
DOORHEAD - 11 1/2" = 1' - 0"
SEALANT, EA. SIDE
4"
4" REINF. CMU WALL(SEE STRUCT. DWGS.)
HM FRAME (PTD.)GROUT SOLID
SEALANT, EA. SIDE
MASONRY ANCHOR(-SEE SPECS)
DOOR AS SCHEDULED
2"
DOORHEAD - 21 1/2" = 1' - 0"
STEEL LINTEL, PAINT(SEE STRUCT. DWGS.)
8" REINF. CMU WALL (SEE STRUCT. DWGS.)
EXT. INT.
BACKER ROD / SEALANTEA. SIDE
ALUM. FRAME
FRP DOOR (AS SCHEDULED)
2"
BACKER ROD / SEALANT EA. SIDE
REINF. CMU WALL (SEE STRUCT. DWGS.)
2"
DOORJAMB - 11 1/2" = 1' - 0"
DOORJAMB - 21 1/2" = 1' - 0"
4 3/4"
5/8" GYP. BD., PAINT WITH 2 1/2" RIGID INUSL. FASTENED TO 2x4 VERT. WD. FURRING AT 16" O.C.(AT SURVEILLANCE ROOM 03A ONLY)
ALUM. FRAME (NON-INSULATED)
FRP DOOR (NON-INSULATED)
4 3/
4"
1"
SYNTHETIC STONE VENEER (ONE SIDE AT DOOR 03 ONLY)
5/8" GYP. BD., PAINT WITH 2 1/2" RIGID INUSL. FASTENED TO 2x4 VERT. WD. FURRING AT 16" O.C.(AT SURVEILLANCE ROOM 03A ONLY)
WINDOW SILL R.O.@ 3'-4" A.F.F.
BULLNOSE CMU SILL
WINDOW HEAD -11 1/2" = 1' - 0"
WINDOW SILL1 1/2" = 1' - 0"
STEEL LINTEL, PAINT(SEE STRUCT. DWGS.)
8" REINF. CMU WALL(SEE STRUCT. DWGS.)
EXT. INT.
BACKER ROD / SEALANTEA. SIDE
EXT.
INT.
EXT. INT.
8" REINF. CMU WALL(SEE STRUCT. DWGS.)
TRANSLUCENT SANDWICH PANEL SYSTEM
WINDOW HEAD R.O.@ 8'-0" A.F.F.
MTL. DRIP EDGE
TRANSLUCENT SANDWICH PANEL SYSTEM AND FRAME
MTL. DRIP EDGE
BACKER ROD / SEALANT, EA. SIDE
WINDOW JAMB -11 1/2" = 1' - 0"
8" REINF. BULLNOSE CMU(SEE STRUCT. DWGS.)
EXT.
INT.
TRANSLUCENT SANDWICH PANEL SYSTEM AND FRAME
BULLNOSE CMU SILL BELOW
BACKER ROD / SEALANT, EA. SIDE
MTL. DRIP EDGE BELOWEXT. INT.
ALUM. FRAME
DOOR AS SCHEDULED
REINF. CONC. SLAB(SEE STRUCT. DWGS.)
1" EXPANSION JOINT
ALUM. THRESHOLD SET IN BEDOF SILICONE SEALANT
DOOR THRESHOLD -11 1/2" = 1' - 0"
MAX
.1/
2"
INTEGRAL SWEEP (SEE SPEC.
4 1/4"
4 1/
2"
2 3/4"
2 3/4"
2 3/
4"
1"
8" REINFORCED CONCRETE BLOCK (WIDTH = 7 5/8")1
REFER TO ROOM FINISH SCHEDULE, FLOOR PLANS, WALL SECTIONS, INTERIOR ELEVATIONS & SPECIFICATIONS FOR ALL FINISHES OR OTHER VARIATIONS IN MATERIALS.
REFER TO STRUCTURAL DRAWINGS FOR CMU WALL REINFORCING.
REFER TO MECH./ELEC./PLUMB. DWGS. FOR ADDITIONAL INFO. AND COORDINATION OF EQUIPMENT AND INSTALLATIONS.
1.
2.
3.
WALL TYPE NOTES:
WALL TYPES:
6" REINFORCED CONCRETE BLOCK W/ SIMULATED STONE VENEER (WIDTH VARIES 6 3/4" - 8 1/8")
2
4" REINFORCED CONCRETE BLOCK (WIDTH = 3 5/8")3
5/8" GYP. BD., PAINT. WITH 2 1/2" RIGID INSUL. FASTEND TO 2X4 VERT. WD. FURRING AT 16" O.C. FASTENED TO REINF. CONC. BLOCK WALL (CMU WIDTH VARIES SEE PLAN)
4
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
2:53
:36
PM
C:\
Use
rs\t
eklu
m\D
ocum
ents
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg-
tekl
um(R
ecov
ery)
.rvt
A-101
FLOOR PLAN AND
SCHEDULES
TEE
DNM
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
© 2019 LaBella Associates
N
DOOR SCHEDULE
NO.
DOOR FRAME
HEAD JAMB RATING HARDWARE COMMENTSELEV WIDTH HEIGHT MATERIAL ELEV MATERIAL
01 D-1 3' - 0" 7' - 2" FRP. F-1 ALUM. H-2 J-2 -- 1 2
02 D-1 3' - 0" 7' - 2" FRP. F-1 ALUM. H-2 J-2 -- 1 2
03 D-2 (2) 3' - 0" 7' - 2" FRP. F-1 ALUM. H-2 J-2 -- 2 --
03A D-3 3' - 0" 7' - 0" HM. F-2 HM. H-1 J-1 -- 4 1
03B D-3 2' - 6" 7' - 0" HM. F-2 HM. H-1 SIM. J-1 SIM. -- 3 1
FLOOR PLAN KEYNOTES
A1 SECURITY SYSTEM CONTROLS (BY OTHERS)
A2 HEATER TO BE INSTALLED (SEE MECH. DWGS.)
A3 REINF. CONC. PAD. (SEE STRUCT. DWGS)
A4 HOLLOW METAL DOOR AND FRAME.
A5 FIBERGLASS DOOR AND ALUM. FRAME.
A6 FIXED TRANSLUCENT FIBERLASS PANEL SYSTEM WITH FAUX MULLION.
A7 SYNTHETIC STONE VENEER ON 6" REINF. CMU BLOCK WALL.
A8 DRINKING FOUNTAINS W/ (1) STANDARD HEIGHT, (1) ACCESSIBLEHEIGHT, AND (1) BOTTLEFILLER (SEE PLUMB. DWGS.)
A9 ELEC. PANEL TO BE INSTALLED (SEE ELEC. DWGS.)
A10 5/8" GYP. BD.(PAINT), 3" RIGID INSULATION AND 1 1/2" WD. FURRINGFASTENED TO BLOCK WALL @ 24" O.C. (VERT.)
A11 WALL MOUNTED SINK (SEE PLUMB. DWGS.)
A12 WALL MOUNTED URINAL (SEE PLUMB. DWGS.)
A13 WALL MOUNTED TOILET (SEE PLUMB. DWGS.)
A14 FLOOR DRAIN (SEE PLUMB. DWGS.)
A15 WATER HEATER (SEE PLUMB. DWGS.)
A16 WALL MOUNTED GRAB BARS TO BE INSTALLED
A17 1" SOLID PLASTIC TOILET PARTITION
A18 1" SOLID PLASTIC URINAL SCREEN
A19 36"W SOLID PLASTIC TOILET PARTITION DOOR
A20 24"W SOLID PLASTIC TOILET PARTITION DOOR
A21 WALL MOUNTED CHANGING TABLE
A22 WALL MOUNTED ELECTRIC HAND DRYER (SEE ELEC. DWGS.)
A23 BACKFLOW PREVENTER (SEE PLUMB. DWGS.)
A24 ALUM DOOR THRESHOLD SET IN SEALANT.
A25 WD. STUD KNEE WALL TO BE INSTALLED, 5/8" GYP. BD. EACH SIDE ON3 1/2" WD. STUDS @ 16" O.C. (OVERALL WIDTH 4 3/4") TOP OF WALLAT 5'-0".
A26 PLASTIC LAMINATE COUNTERTOP TO BE INSTALLED, HEIGHT AT 3'-6"(SEE SPEC)
ROOM FINISH SCHEDULE
ROOM NUMBER ROOM NAME FLOOR FINISH BASE MATERIAL WALL FINISH CEILING MATERIAL REMARKS
01 WOMENS HON. CONC. (SEAL) - PAINT. GYP. BD. (PT.) 2, 3
02 MENS HON. CONC. (SEAL) - PAINT GYP. BD. (PT.) 2, 3
03 STORAGE CONC. (SEAL) - - EXP. STRUCT. (PT.)
03A SURVEILLANCE EQUIPMENT CONC. (SEAL) 1x4 PVC TRIM (PT.) PAINT. GYP. BD. (PT.) 1
03B PLUMBING CHASE CONC. (SEAL) - - EXP. STRUCT. (PT.)
FINISH SCHEDULE REMARKS:
1. GYP. BD. CEILING WITHIN THIS ROOM TO RECIEVE BATT. INSUL., R-38 MIN.2. 1x4 PVC TRIM BOARD (PT.) AT CEILING PERIMETER.3. ALTERNATE #3 - EPOXY FLOOR AND 4" BASE
DOOR SCHEDULE REMARKS:
1. DOOR AND FRAME TO BE PAINTED.2. ALUM. THRESHOLD TO BE PROVIDED - DOOR THRESHOLD 1
SCALE: 1/4" = 1'-0"A-101
1 FLOOR PLAN
SCALE: 1 1/2" = 1'-0"A-101
4 DOOR AND WINDOW DETAILS
Revisions
NO: DATE: DESCRIPTION:
E.F.
E.F.
E.F.
C1C1
C1C1
C1C1
C2C2
C2C2
C4
C3C3
C3
C3
C5
C5
C6
C7
C7
C5
C5
C6
C6
C6C6
C6C6C6
C6
C6C6
C6
C7
C6
C6
2
A-301
___________
4
A-301
___________
4
A-301
___________
2
A-301
___________
SLOPE
4 : 12
SLOPE
4 : 12
6" O
VER
HAN
G
6" O
VER
HAN
G
1' - 4" OVERHANG
1' - 4" OVERHANG
R1R1
R1R1
R4
R3
R3R3
R3
R2
R5R5
R5
R4R4R4
R4R4
EXTERIOR FACECMU WALL BELOW (TYP).
6' - 0" 6' - 0"
1' -
4"
R1R1
R1R1
1' -
4"
1' -
4"
6' - 0"6' - 0"
1' -
4"
1' - 4"
R4 R4
R6R6
R6 R6
SCRATCH COAT
AT DOOR 03 REFER TO JAMB-2 DETAIL FOR CONDITION AT NEW DOOR FRAME
6" REINF. CMU WALL ATSTONE VENEER CORNERS
CMU CELL GROUTING AND REINFORCEMENT(SEE STRUCT. DWGS.)
SYNTHETIC STONE VENEER
FLUSH
FLUSH
(VAR
IES,
SEE
ELE
VATI
ON
S)
(VARIES, SEE ELEVATIONS)
SEALANT
SEALANT
2' - 10 1/2"
(CLR.)
2' - 6"
(CLR.)
2' - 6"
(CLR.)
3' - 0"
(CLR.)
5' - 0"
T1T1
T3T3
T2T2
T8T8
T7 T7
T6T6
T6T5T5
T4T4
T11
T15
T16
T17
(CLR.)
5' - 7"
(CLR.)
3' - 0"
(CLR.)
3' - 0"
(CLR.)
3' - 0"
T1T1
T5T5
T4T4
T2 T2 T2T2
T8T8
T7 T7 T7 T7
T11
T15
T16
T17
T1T1
T12T12
T10
T9
T13
T14
T16
4' -
0"
3' - 0"
3' -
0"
2' -
10"
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/26
/201
9 1
2:53
:38
PM
C:\
Use
rs\t
eklu
m\D
ocum
ents
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg-
tekl
um(R
ecov
ery)
.rvt
A-102
REFLECTED CEILING PLAN,
ROOF PLAN, INTERIOR
ELEVATIONS AND DETAILS
TEE
DNM
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
SCALE: 1/4" = 1'-0"A-102
1 FIRST FLOOR REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"A-102
2 ROOF PLAN
NN
ROOF KEYNOTES
R1 ARCHITECTURAL ASPHALT SHINGLES AND 30LB. FELT PAPER
R2 ROOF RIDGE VENT.
R3 EXTENT OF ICE AND WATER SHIELD TO BE INSTALLED.
R4 5" K STYLE 0.027 ALUMINUM GUTTERS. (SEAMLESS)
R5 ROOF VENT (SEE MECH. DWGS.)
R6 2" X 3" .019 ALUMINUM DOWNSPOUTS TO GRADE.
CEILING PLAN KEY NOTES
C1 1/2" GYP. BD. CEILING (PAINT.), ON 2x4 FURRING STRIPS@ 16" O.C., FASTEN TO UNDERSIDE OF JOIST.
C2 AREA OPEN TO ROOF, EXPOSED WOOD JOISTS ANDDECK (SEE STRUCT. DWGS.)
C3 VENTED VINYL SOFFIT.
C4 PVC CLAD WOOD BEAM.
C5 MECHANICAL EQUIPMENT TO BE INSTALLED (SEE MECH.DWGS.)
C6 LIGHT FIXTURE TO BE INSTALLED (SEE ELEC. DWGS.)
C7 EMERENCY LIGHT FIXTURE TO BE INSTALLED (SEE ELEC.DWGS.)
SCALE: 1" = 1'-0"A-102
3 CORNER DETAIL
SCALE: 1/4" = 1'-0"A-102
4 INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"A-102
5 INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"A-102
6 INTERIOR ELEVATION
INTERIOR ELEVATION KEYNOTES
T1 CMU. WALL TO BE PAINTED.
T2 1" SOLID PLASTIC WALL AND FLOOR MOUNTED TOILET PARTITIONTO BE INSTALLED.
T3 1" SOLID PLASTIC FLOOR MOUNTED URINAL SCREEN TO BEINSTALLED.
T4 WALL MOUNTED SINK TO BE INSTALLED (SEE PLUMB. DWGS.)
T5 24" W X 36" H MIRROR TO BE INSTALLED.
T6 URINAL TO BE INSTALLED (SEE PLUMB. DWGS.)
T7 TOILET TO BE INSTALLED (SEE PLUMB. DWGS.)
T8 GRAB BARS TO BE INSTALLED (SEE G-002 FOR TYP. HC. MOUNTINGHEIGHTS)
T9 WALL MOUNTED CHANGING TABLE TO BE INSTALLED.
T10 WALL MOUNTED ELEC. HAND DRYER TO BE INSTALLED W/ METALWALL PROTECTION PLATE (SEE ELEC. DWGS.)
T11 FRP. DOOR W/ ALUM. FRAME (SEE DOOR SCHEDULE)
T12 FIXED TRANSLUCENT FIBERLASS PANEL SYSTEM WITH FAUXMULLION.
T13 3'W x 4'H 304 STAINLESS STEEL RIGIDIZED METALS CORP., .024GA. PATTERN: SWL, FINISH: SATIN #4 W/430 STAINLESS STEELJ-CHANNEL ON ALL 4' SIDES (NO EXPOSED FASTENERS)
T14 EMERGENCY LIGHT FIXTURE TO BE INSTALLED (SEE ELEC. DWGS.)
T15 WALL MOUNTED LIGHT FIXTURE TO BE INSTALLED (SEE ELEC.DWGS.)
T16 1X3 PINE TRIM, PAINT.
T17 SOAP DISPENSER
Revisions
NO: DATE: DESCRIPTION:
FIN. FLOOR
0' - 0"
T.O. CMU
10' - 0"
B.O. FOOTING
-4' - 4"
412
4
12
E1
E16
E3
E9
E1
E2E2
E9
E3
E4
E17E10
E13E13
E15
E4
E12
E14
E12
E17
3' - 8" 2' - 0"
E5
E6 4
A-301
___________
CL
CL
4' -
6"
E5
E20
C.J. C.J.
1
A-301
___________
1
A-301
___________
FIN. FLOOR
0' - 0"
T.O. CMU
10' - 0"
B.O. FOOTING
-4' - 4"
2' - 0"2' - 0"
E3E3
E16
E14
E2E2
E1E1
E13E13
E12
2
A-301
___________
C.J. C.J.
1
A-301
___________
1
A-301
___________
FIN. FLOOR
0' - 0"
T.O. CMU
10' - 0"
B.O. FOOTING
-4' - 4"
E2E2E2E2
E11
E3E3E3E3
E16
E4
E13E13
E17
E14
E2E2E1E1 E1E1
3' - 8" 3' - 8"18' - 0"
E5
E12
2
A-301
___________
E18
36" M
AX.
38" M
AX.
43" M
AX.
C.J. C.J.
9' -
0"
R 18' - 0"
FIN. FLOOR
0' - 0"
T.O. CMU
10' - 0"
B.O. FOOTING
-4' - 4"
4
12
4
12
E1
E16
E3
E9
E2
E9
E3
E8
E4
E6
E10
E13E13
E15E15
E14
E17
E12
E12 E1
E4
2' - 0"
E2
3' - 8"
E5
E5
4
A-301
___________
CL
CL
4' -
6"
C.J.
C.J.
C.J.
5
A-201
___________
CMU COLOR KEY
SPLIT FACE CMU (COLOR A)
SPLIT FACE CMU (COLOR B)
5" VINYL SIDING
BUILDING WRAP
1x4 PVC TRIMBOARD, PAINT.
PREFABRICATED WOOD TRUSSES
DOUBLE TOP PLATE(SEE STRUCT. DWGS.)
1/2" APA RATED SHEATHING(SEE STRUCT. DWGS.)
T.O. CMU
10' - 0"
MTL. DRIP EDGE(PRE-FIN.)
SIMULATED STONE VENEER
BACKER ROD AND SEALANT
6" REINF. CMU WALL (SEE STRUCT. DWGS.)
ANCHOR BOLT(SEE STRUCT. DWGS.)
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/23
/201
9 3
:13:
59
PM
C:\
Use
rs\t
eklu
m\D
ocum
ents
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg-
tekl
um(R
ecov
ery)
.rvt
A-201
EXTERIOR ELEVATIONS
TEE
DNM
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
SCALE: 1/4" = 1'-0"A-201
4 EAST ELEVATIONSCALE: 1/4" = 1'-0"A-201
3 NORTH ELEVATION
SCALE: 1/4" = 1'-0"A-201
1 SOUTH ELEVATIONSCALE: 1/4" = 1'-0"A-201
2 WEST ELEVATION
ELEVATION KEY NOTES
E1 8" REINF. SPLIT FACE CMU BLOCK (COLOR A).
E2 8" REINF. SPLIT FACE CMU BLOCK (COLOR B).
E3 SYNTHETIC STONE VENEER.
E4 .042" DOUBLE 5" WOOD GRAIN CLAPBOARD VINYLSIDING.
E5 5/4" X 4" PVC TRIM BOARD CORNERS W/ RABBETEDCORNERS TO ACCEPT VINYL SIDING.
E6 1x PVC TRIM BOARDS (PAINT.) W/ RABETTED CORNERS.
E8 FIBERGLASS DOOR AND FRAME.
E9 FIXED TRANSLUCENT FIBERLASS PANEL SYSTEM WITHFAUX MULLIONS.
E10 36" DIA. ROUND POLYURETHANE LOUVER WITH TRIM.MODEL FRLV36 BY FYPON OR EQUAL.
E11 DRINKING FOUNTAINS W/ (1) STANDARD HEIGHT, (1)ACCESSIBLE HEIGHT, AND (1) BOTTLEFILLER (SEEPLUMB. DWGS.)
E12 2" X 3" PREFIN. ALUM. DOWNSPOUT. W/ SPLASH BLOCK.
E13 REINF. CONCRETE FOUNDATION AND FOOTING.
E14 ROOF RIDGE VENT.
E15 BRICK VENT TO BE INSTALLED (SEE MECH. DWGS.)
E16 ASPHALT SHINGLE ROOFING.
E17 5" PREFIN. ALUM. K-STYLE GUTTER.
E18 EMERGENCY LIGHT FIXTURE TO BE INSTALLED (SEEELEC. DWGS.)
E20 METERS (SEE ELEC. DWGS.)
SCALE: 1 1/2" = 1'-0"A-201
5 DETAIL
Revisions
NO: DATE: DESCRIPTION:
FIN. FLOOR
0' - 0"
T.O. CMU
10' - 0"
B.O. FOOTING
-4' - 4"
(1312.0)
(TO CMU)
1' - 4"
(SPL
IT F
ACE
CO
LOR
A)
3' -
4"
(SPL
IT F
ACE
CO
LOR
B)
6' -
8"
FINISHED GRADE(SEE SITE PLAN)
6" GRAVEL SUB-BASE
4" THICK CONC. SLAB(ENTIRE PERIMETER)
8" REINF. SPLIT FACE CONC. BLOCK (SEE STRUCT. DWGS.)
APA RATED SHEATHING(SEE STRUCT. DWGS.)
SEE ROOF PLAN FOR EXTENT OF ICE AND WATER SHIELD, SELF ADHERING MEMBRANE
ARCHITECTURALASPHALT SHINGLE
4" REINF. CONC. BLOCK
1/2" GYP. BD CEILING.ON 2x3 FURRING STRIPS @ 16" O.C., FASTENTO UNDERSIDE OF JOIST
ASPHALT PATH(SEE SITE PLAN)
6" GRAVEL SUB-BASE
SPLIT FACE CMU BEYOND
FIBERGLASS DOOR AND ALUMINUM FRAME
(2) 2X3 WD. FURRING AT 16" O.C.
4
12
4
12
6" GRAVEL SUB-BASE
REINF. CONC. SLAB(SEE STRUCT. DWGS.)
FLOOR AS SCHEDULED
WOMENS01
STORAGE03
RIDGE VENT
APPROVED BACKFILL
APPROVED BACKFILL
2" RIGID INSUL.4'-0" BEYOND EACH SIDEOF PLUMB. CHASE
PRE-ENGINEERED WOOD TRUSS(SEE STRUCTURAL DWGS.)
VINYL VENTED SOFFIT
DOWEL AS REQ'D.
5" PREFIN. ALUM. K-STYLE GUTTER
REPAIR LAWN AT AREAS OF DISTURBED WORK(PROVIDE TOPSOIL AND SEED AS REQ'D.)
SURVEILLANCEEQUIPMENT
03A
8" FULLY GROUTED REINF.CMU FOUNDATION WALL AND CONC. FOOTER(SEE STRUCT. DWGS)
2x4 VERT. WD. FURRING @ 16" O.C.
3" RIGID INSUL.
5/8" GYP. BD., PAINT.
A-301
2
ENGINEERED FILL (SEE STRUCT. DWGS)
UNDISTURBED SUITABLE BEARING GRADE
ENGINEERED FILL (SEE STRUCT. DWGS)
UNDISTURBED SUITABLE BEARING GRADE
REINF. CONC. SLABW/ THICKENED EDGE(SEE SRUCT. DWGS.)
ARCHED BEAM(SEE DETAIL 5/A-301)
1X3 PAINTED PINE TRIM AT ENTIRE CEILING PERIMETER, PAINT.
UNFACED BATT INSUL (R-38) AT SURVEILLANCE EQUIPMENT ROOM O3A
VENTED VINYL SOFFIT
A-301
5
VAPOR BARRIER
30# FELT PAPER
1/2" APA RATED SHEATHING(SEE STRUCT. DWGS.)
BUILDING WRAP
VINYL SIDINGA-301
4
8" FULLY GROUTED REINF. CMU FOUNDATION WALL AND CONC. FOOTER(SEE STRUCT. DWGS)
RESTROOM SIGNAGE(SEE SPEC)
1' - 4"
5" K-STYLE PREFIN.SEAMLESS ALUM. GUTTER
PRE-FIN. ALUM.DRIP EDGE
2x WD. BLOCKING
APA RATED SHEATHING(SEE STRUCT. DWGS.)
ARCHITECTURALASPHALT SHINGLE
30# FELT PAPER
5" VINYL SIDING
BUILDING WRAP
1x4 PVC TRIMBOARD, PAINT.
PREFABRICATED WOOD TRUSSES
1x PVC TRIMBOARD, PAINT.
2x WD. BLOCKING
8" REINF. CMU WALL (SEE STRUCT. DWGS.)
2x4 WD. BLOCKING
5" K-STYLE PREFIN.SEAMLESS ALUM. GUTTER
PRE-FIN. ALUM.DRIP EDGE
2x WD. BLOCKING
TRIPLE 4" .040"PERFORATED VINYLSOFFIT W/ J-MOLD
1x PVC TRIMBOARD, PAINT.
APA RATED SHEATHING(SEE STRUCT. DWGS.)
ARCHITECTURALASPHALT SHINGLE
30# FELT PAPER
1' - 4"
PREFABRICATED WOOD TRUSSES
DOUBLE TOP PLATE(SEE STRUCT. DWGS.)
ANCHOR BOLT(SEE STRUCT. DWGS.)
T.O. CMU
10' - 0"
5" VINYL SIDING
BUILDING WRAP
1x4 PVC TRIMBOARD, PAINT.
2x WD. BLOCKING(RADIUSED)
1x PVC TRIMBOARD, PAINT.(1 PIECE RADIUS)
(2) 3/4" PLYWOOD (RADIUSED)
TRIPLE 4" .O4O"SOLID VINYL SOFFITW/ J-MOLD
PREFABRICATED WOOD TRUSSES
(2)2x3 FURRING STRIPS @ 16" O.C.
DOUBLE TOP PLATE(SEE STRUCT. DWGS.)
1/2" APA RATED SHEATHING(SEE STRUCT. DWGS.)
8" REINF. CMU WALL (SEE STRUCT. DWGS.)
ANCHOR BOLT(SEE STRUCT. DWGS.)
T.O. CMU
10' - 0"
CMU WALL BEYOND
(RAKE.)
6"
PRE-FIN. ALUM.DRIP EDGE
APA RATED SHEATHING(SEE STRUCT. DWGS.)
ARCHITECTURALASPHALT SHINGLE
30# FELT PAPER
TRIPLE 4" .040"PERFORATED VINYLSOFFIT W/ J-MOLD
1x PVC TRIMBOARD, PAINT.
APA RATED SHEATHING(SEE STRUCT. DWGS.)
5" VINYL SIDING
BUILDING WRAP
1x4 PVC TRIMBOARD, PAINT.
DOUBLE TOP PLATE(SEE STRUCT. DWGS.)
8" REINF. CMU WALL (SEE STRUCT. DWGS.)
ANCHOR BOLT(SEE STRUCT. DWGS.)
1x4 PVC TRIMBOARD, PAINT.
DOUBLE TOP PLATE(SEE STRUCT. DWGS.)
T.O. CMU
10' - 0"
MTL. DRIP FLASHING
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/23
/201
9 3
:13:
59
PM
C:\
Use
rs\t
eklu
m\D
ocum
ents
\218
2911
- N
ew P
ark
Am
eniti
es B
ldg-
tekl
um(R
ecov
ery)
.rvt
A-301
SECTIONS AND DETAILS
TEE
DNM
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
SCALE: 1/2" = 1'-0"A-301
1 BUILDING SECTION 1
SCALE: 1 1/2" = 1'-0"A-301
2 DETAILSCALE: 1 1/2" = 1'-0"A-301
4 DETAILSCALE: 1 1/2" = 1'-0"A-301
5 DETAILSCALE: 1 1/2" = 1'-0"A-301
3 DETAIL
Revisions
NO: DATE: DESCRIPTION:
BRANCH OFF TOP OF PIPE
PIPE TURNED UP
PIPE TURNED DOWN
BRANCH OFF BOTTOM OF PIPE
REDUCER
PIPE BREAK
BALL VALVE
BUTTERFLY VALVE
GATE VALVE
DRAWING SYMBOLS
ANGLE VALVE
CHECK VALVE
BALANCE VALVE
SHUT OFF VALVE (GATE, BALL,OR BUTTERFLY - REFER TO SPECS)
MOTOR OR SOLENOIDCONTROL VALVE (3-WAY)
STEAM TRAP
MOTOR OR SOLENOIDCONTROL VALVE
PRESSURE REDUCING VALVE
TRIPLE DUTY VALVE
RELIEF VALVE
STRAINER
UNION
PRESSURE GAUGE
PUMP
EQUIPMENT TO BE REMOVED
KEYNOTE
SECTION CALLOUT
NEW CONNECTION TO EXISTING
REMOVE TO THIS POINT)
DEMOLITION KEYNOTE
DETAIL NUMBER
RETURN AIR
SUPPLY AIR
DUCT (DIMENSIONS SHOWN INDUCT. DIMENSIONS IN INCHES.)
DUCT SECTION - EXHAUST AIR
DUCT SECTION - SUPPLY AIR
DUCT SECTION - RETURN AIR
14" ROUND DUCT
VOLUME DAMPER
DUCT (DIMENSIONS SHOWN BYLEADER. DIMENSIONS IN INCHES.)
14" Ø
MITERED ELBOW W/ TURNING VANES
INSULATED DUCT (DIM. IS INTERNAL)
EXHAUST GRILLE
REGISTER OR GRILLE - TOP NUMBERREPRESENTS TAG, SEE SCHEDULE;BOTTOM NUMBER REPRESENTS CFM.
RETURN GRILLE
DIFFUSER - LETTER REPRESENTS TAG,SEE SCHEDULE; NUMBER REPRESENTSCFM
SUPPLY DIFFUSER
T
S
H
THERMOSTAT
SENSOR
HUMIDISTAT
APPLICABLE CODES ABBREVIATIONS
%ACADJAFFAFGALTAMBAMPANSIAPPROXAVGBFPBHPBLDGBOBSMTBTUBVCAPCIPCLGCLRCOCOLCONNCONCCONTCU FTCVDCDADCVDCWDEMODHWDIADIPDWHDWVDWG(E)ENGREQESTETREWHEWTEXEXISTEXPEXT°F
PERCENTALTERNATING CURRENTADJACENTABOVE FINISHED FLOORABOVE FINISHED GRADEALTERNATEAMBIENTAMPERE (AMP,AMPS)AMERICAN NATIONAL STANDARD INSTITUTEAPPORXIAMTE (LY)AVERAGEBACKFLOW PREVENTERBRAKE HORSEPOWERBUILDINGBOTTOM OFBASEMENTBRITISH THERMAL UNITBALANCING VALVECAPACITYCAST IRON PIPECEILINGCLEARCLEANOUT or CARBON MONOXIDECOLUMNCONNECTIONCONCRETECONTINUOUSCUBIC FEETVALVE FLOW COEFFICIENTDOUBLE CHECK DETECTOR ASSEMBLYDETECTOR CHECK VALVEDOMESTIC COLD WATERDEMOLISH or DEMOLITIONDOMESTIC HOT WATERDIAMETERDUCTILE IRON PIPEDOMESTIC WATER HEATERDRAIN, WASTE, & VENTDRAWINGEXISTINGENGINEEREQUALESTIMATEDEXISTING TO REMAINELECTRIC WATER HEATERENTERING WATER TEMPERATUREEXISTINGEXISTINGEXPANSIONEXTERIORDEGREES FAHRENHEIT
FAFINFLFLAFPMFPSFTFUTGAGALGCGPMGPDGPHHDHGHORIZHPHPCHPSHRHVACHZIDININSULINTIPSINVKWKWHLBSLFLGLOCLPCLPSLRALWTMATLMAXMBHMECHMFGMINMISCMOCPMPCMPSMTGN/ANC
FREE AREAFINISHEDFLOORFULL LOAD AMPSFEET PER MINUTEFEET PER SECONDFOOT OR FEETFUTUREGAGE OR GAUGEGALLONSGENERAL CONTRACTORGALLONS PER MINUTEGALLONS PER DAYGALLONS PER HOURHEADMERCURYHORIZONTALHORSEPOWERHIGH PRESSURE CONDENSATEHIGH PRESSURE STEAMHOURHEATING, VENTILATING, AND AIR CONDITIONINGFREQUENCYDIAMTER, INSIDEINCHINSULATIONINTERIORIRON PIPE SIZEINVERTKILOWATTKILOWATT HOURPOUNDSLINEAR FEETLENGTHLOCATIONLOW PRESSURE CONDENSATELOW PRESSURE STEAMLOCKED ROTOR AMPSLEAVING WATER TEMPERATUREMATERIALMAXIMUMBTU PER HOUR (THOUSAND)MECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMAXIMUM OVERCURRENT PROTECTIONMEDIUM PRESSURE CONDENSATEMEDIUM PRESSURE STEAMMOUNTINGNOT APPLICABLENORMALLY CLOSED
NICNONPTNRSNTSOCODOS&YPCPLBGPHPRESSPSFPSIPSIGPRVRCVRRECIRCRHWRORPDARPMRPZSCHSPECSPLYSQSQ FTSQ INSTDSUCTT'STATTBDTCTDTEMPTMVTOTYPVVACVARVELVIFVOLWW/W/OWCOWHAWMWPDWTWWP
NOT IN CONTRACTNORMALLY OPENNATIONAL PIPE TREADNON-RISING STEMNOT TO SCALEON CENTERDIAMETER, OUTSIDEOUTSIDE SCREW AND YOKEPLUMBING CONTRACTORPLUMBINGPHASE (ELECTRICAL)PRESSUREPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPSI GUAGEPRESSURE REDUCING VALVERECEIVERRECIRCULATEHOT WATER RE-CIRCULATIONROUGH OPENINGREDUCED-PRESSURE DETECTOR ASSY.REVOLUTIONS PER MINUTEREDUCED-PRESSURE ZONESTEAM CAPTURE HOODSPECIFICATIONSUPPLYSQUARESQUARE FOOT (FEET)SQUARE INCH (INCHES)STANDARDSUCTIONTHERMOSTATTO BE DETERMINEDTEMPERATURE CONTROL CONTRACTORTEMPERATURE DIFFERENCETEMPERATURETHERMOSTATIC MIXING VALVETOP OFTYPICALVOLTVACUUMVARIABLEVELOCITYVERIFY IN FIELDVOLUMEWATTWITHWITH OUTWALL CLEANOUTWATER HAMMER ARRESTERWATER METERWATER PRESSURE DROPWEIGHTWORKING WATER PRESSURE
NOTE:
SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
1
8
750
A
125
18/8
18/8
18/8
1
M-2
A
M-2
A
M
EQUIPMENT DESIGNATIONS
HC
HP
HWP
HX
PHC
L
PRV
VAV
UH
CA
AHU
CFP
CC
B
CHP
CH
CT
CP
CAV
EF
FT
FCU
CUH
AS
CRU
CV
VD
RCRAC
DHW
ET
FP
PRG
HU
MAU
P
PPU
RTU
RCP
UV
WS
CU
ACU
AD
BDD
MD
VFD
EXISTING DUCTWORK, PIPE, EQUIPMENT
NEW DUCTWORK, PIPE, EQUIPMENT
DUCTWORK, PIPE, EQUIPMENT
TO BE REMOVED
CHWS
GHR
CHILLED WATER SUPPLY
GLYCOL HOT WATER RETURN
CHILLED WATER RETURNCHWR
HPLS
HPLR
HEAT PUMP LOOP SUPPLY
HEAT PUMP LOOP RETURN
GLYCOL HOT WATER SUPPLY
GHSHPC
CA
NG
C
HIGH PRESSURE CONDENSATE
COMPRESSED AIR
NATURAL GAS
CONDENSATE
VAC VACUUM
HPS HIGH PRESSURE STEAM
LPC LOW PRESSURE CONDENSATE
LPS LOW PRESSURE STEAM
MPC
MPS MEDIUM PRESSURE STEAM
RHL REFRIGERANT H/L PRESSURE
RL
RS
REFRIGERANT LIQUID
REFRIGERANT SUCTION
SV STEAM VENT
CD CONDENSATE DRAIN
CTR
CTS
COOLING TOWER RETURN
COOLING TOWER SUPPLYHWS
HWR
HOT WATER SUPPLY
HOT WATER RETURN
DN
DIRECTION OF FLOW
DIRECTION OF PITCH
MU MAKE-UP WATER
PC PUMPED CONDENSATE
HOT WATER PUMP
HEAT PUMP
HEATING COIL
HEAT EXCHANGER
PREHEAT COIL
LOUVER
PRESSURE REDUCING VALVE
VARIABLE AIR VOLUME BOX
UNIT HEATER
AIR COMPRESSOR
COOLING COIL
BOILER
AIR HANDLING UNIT
CHEMICAL FEED PUMP
COOLING TOWER
CHILLER
CONDENSATE PUMP
CHILLED WATER PUMP
EXHAUST FAN
CONSTANT AIR VOLUME BOX
FINNED TUBE
FAN COIL UNIT
CABINET UNIT HEATER
AIR SEPARATOR
CONDENSATE RETURN UNIT
CONTROL VALVE
VOLUME DAMPER
REGISTERCOMPUTER ROOM UNIT
DOMESTIC WATER HEATER
EXPANSION TANK
FIRE PUMP
GAS PRESSURE REGULATOR
HUMIDIFIER
MAKE UP AIR UNITS
PUMP
PUMPING PACKAGED UNIT
ROOF TOP UNIT
RADIANT CEILING PANEL
UNIT VENTILATOR
WATER SOFTENER
CONDENSING UNIT
AIR CONDITIONING UNIT
ACCESS DOOR
BACK DRAFT DAMPER
MOTORIZED DAMPER
VARIABLE SPEED DRIVE
FIRE DAMPER
SD
SMOKE DAMPER
F/SCOMBINATION FIRE / SMOKE DAMPER
AD
AD
AD
ACCESS DOOR TO BE LOCATEDON MOST ACCESSIBLE SIDE OF DUCT
ACCESS DOOR TO BE LOCATEDON MOST ACCESSIBLE SIDE OF DUCT
ACCESS DOOR TO BE LOCATEDON MOST ACCESSIBLE SIDE OF DUCT
FD
WALL OR DUCT MOUNTED SUPPLY GRILLE
WALL OR DUCT MOUNTED RETURN OR EXHAUST GRILLE
VRF FAN COIL CASSETTE UNIT
MOTOR OPERATED DAMPER
FLEX DUCT
NOTE:
SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
BUILDING CODE OF NEW YORK STATEENERGY CODE OF NEW YORK STATEMECHANICAL CODE OF NEW YORK STATEFIRE CODE OF NEW YORK STATEPLUMBING CODE OF NEW YORK STATEENERGY CONSERVATION CODE OF NEWYORK STATEACCESSIBLE AND USABLE BUILDING ANDFACILITIES-CABO/ANSI A117.1NATIONAL ELECTRIC CODENATIONAL FIRE CODE NFPA 13
123456
7
89
NOTE:NOT ALL SYMBOLS, ABBREVIATIONS ANDEQUIPMENT DESIGNATIONS MAY APPLY TO THISPARTICULAR PROJECT. ANY ADDITIONS OROMISSIONS FROM THIS LEGEND SHEET DOES NOTIMPLY INCLUSION AND/ OR EXCLUSIONS OF ANYPARTICULAR ITEM FROM THIS PROJECT.
MEDIUM PRESSURE CONDENSATE
GENERAL NOTES
C02 CARBON DIOXIDE SENSOR
IW INDIRECT WASTE
18" x 8" FLAT OVAL DUCT18/8
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
4/25
/201
9 2
:44:
21
PM
C:\
Use
rs\J
Jarr
ett\
Doc
umen
ts\2
1829
11 -
New
Par
k A
men
ities
Bld
g -
MP
_jja
rret
t.rvt
M-001
MECHANICAL LEGEND
SHEET
JLJ
JSN
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES
BUILDING
VILLAGE OF CELORON
DUCTWORK GENERAL NOTES
1 HVAC CONTRACTOR TO PROVIDE CRANE AND NECESSARY EQUIPMENT TO HOIST ROOF MOUNTED HVAC EQUIPMENT FROMSITE TO FINAL ROOF LOCATION. GENERAL CONTRACTOR TO PROVIDE ALL ROOF PENETRATIONS REQUIRED TOACCOMMODATE HVAC EQUIPMENT OPENINGS AND SET CURBS. HVAC CONTRACTOR TO COORDINATE EXACT LOCATION OFPENETRATIONS WITH G.C. AND SHALL ASSIST WITH SETTING ALL HVAC EQUIPMENT ROOF CURBS. HVAC CONTRACTORSHALL BE RESPONSIBLE FOR TEMPORARY CAP OF ALL ROOF PENETRATIONS IN INTERIM FROM TIME PENETRATIONS ARECOMPLETE TO TIME EQUIPMENT IS SET ON ROOF CURBS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FLASHINGALL EQUIPMENT CURBS AND OTHER HVAC RELATED ROOF PENETRATIONS. HVAC CONTRACTOR SHALL REMOVE ANDDISPOSE OF TEMPORARY CAP WHEN EQUIPMENT IS SET IN PLACE.
2 PROVIDE 45 DEGREE SHOE-TAP FITTING AND VOLUME DAMPER AT ALL BRANCH DUCT TAKE-OFFS (TOP, SIDE AND BOTTOM)FOR SUPPLY, RETURN AND EXHAUST AIR, UNLESS SHOWN OR NOTED OTHERWISE. VOLUME DAMPERS SHALL BE OMITTEDFROM VAV INLET BRANCH DUCTWORK.
3 COORDINATE HVAC INSTALLATION WITH STRUCTURE, CEILING, LIGHTING, CONDUIT, HEATING AND DOMESTIC PIPING, STORMAND SANITARY DRAIN PIPING (ALL TRADES). PREPARE AND SUBMIT FULL COORDINATION DRAWINGS FOR APPROVAL BYENGINEER PRIOR TO ORDERING MATERIALS AND/OR BEGINNING CONSTRUCTION.
4 INSULATE OR LINE DUCTWORK AS SPECIFIED IN THE MECHANICAL INSULATION AND METAL DUCTS SPECIFICATIONS ORNOTED ON DRAWINGS. NOTE THAT DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE NET CLEAR DIMENSIONS.
5 ALL 90 DEGREE RECTANGULAR ELBOWS AND DUCTWORK TEES SHALL BE HARD MITERED WITH FACTORY TURNING VANES.TURNING VANES SHALL BE OMITTED FROM AIR TRANSFER DUCT ELBOWS.
6 ALL DUCTWORK PASSING THROUGH NON-FIRE RATED WALLS TO BE SEALED AROUND PERIMETER (BOTH SIDES) WITHDRYWALL JOINT COMPOUND OR APPROVED EQUAL.
7 BALANCING CONTRACTOR TO SET MINIMUM OUTSIDE AIR DAMPER POSITION TO MEET VENTILATION AIR QUANTITIESREQUIRED AS SHOWN ON PLANS OR LISTED IN EQUIPMENT SCHEDULES.
8 NATURAL GAS PIPING WHERE REQUIRED SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR, WHICH SHALL INCLUDEFINAL CONNECTIONS TO HVAC EQUIPMENT. COORDINATE ALL EQUIPMENT LOCATIONS THAT REQUIRE NATURAL GAS WITHTHE PLUMBING CONTRACTOR.
9 THE ABOVE GENERAL NOTES APPLY TO ALL HVAC CONSTRUCTION DOCUMENT DRAWINGS.
Revisions
NO: DATE: DESCRIPTION:
T
L-3L-1
EF-1
EF-2
EF-3
H-1
8"Ø EA UP TO
9x6
8"Ø EA UP TO 9x6
6"Ø EA UP
STORAGE03
SURVEILLANCEEQUIPMENT
03A
WOMENS01
MENS02
PLUMBING CHASE03B
16/8 EAM
2
150
16/4 EA DUCT DOWN TO 12" AFF WITH SUPPORT LEGS
1
375
L-2
1
375
1
1
3
4
2
FAN SCHEDULENo. Location Service Type CFM S.P. Fan RPM Fan Drive
Motor DataMax. Sones Weight Notes Model No. Manufacturer
Amps Volts Phase
EF-1 WOMEN'S ROOM EXHAUST CEILING MOUNTED 368 0.25 1350 DIRECT 1.34 115 1 4.5 24 LBS 1,2,4 SP-A390 GREENHECK
EF-2 MEN'S ROOM EXHAUST CEILING MOUNTED 368 0.25 1350 DIRECT 1.34 115 1 4.5 24 LBS 1,2,4 SP-A390 GREENHECK
EF-3 SURVEILLANCE ROOM EXHAUST CEILING MOUNTED 154 0.25 1050 DIRECT 1.70 115 1 3.0 10 LBS 1,3,4 SP-B150 GREENHECK
NOTES:1. PROVIDE RJ-6x9 SLOPED ROOF VENT (COLOR TO MATCH ROOFING, COORDINATE WITH ARCHITECT) W/ INTEGRAL BIRD SCREEN AND BACK DRAFT DAMPER.2. INTERLOCK EF OPERATION WITH OCCUPANCY SENSOR, COORDINATE WITH DIVISION 26.3. PROVIDE LINE VOLTAGE THERMOSTAT.4. PROVIDE HANGING VIBRATION ISOLATION KIT FROM SAME MANUFACTURER AS EXHAUST FAN.
LOUVER SCHEDULENo. Size Depth CFM APD (in) Type Remarks Bird Screen Mat'l Manufacturer Model
L-1 32" x 7-3/4" 4" 375 -- STATIONARY 1,2,3 YES ALUM GREENHECK BVE
L-2 32" x 7-3/4" 4" 375 -- STATIONARY 1,2,3 YES ALUM GREENHECK BVE
L-3 16" x 7-3/4" 4" 150 -- STATIONARY 1,2,3,4 YES ALUM GREENHECK BVE
WALL HEATER SCHEDULENo. Type CFM Cap. MBH Electrical KW Amps Mounting Remarks Manufacturer Model
H-1 Electric -- 3413 120 V 1 8.4 WALL 1 Marley CWH1101DSF
NOTES:1. PROVIDE 1/2" MESH BIRD SCREEN ON REAR OF UNIT.2. PROVIDE BAKED ENAMEL FINISH.3. PROVIDE ALUMINUM EXTENSION DUCT FULL WIDTH OF WALL.4. PROVIDE 120V MOTOR OPERATED DAMPER IN DUCT TO POWER OPEN, SPRING CLOSE.
NOTES:1. PROVIDE INTEGRAL THERMOSTAT, SET AT 55 DEG F.
REGISTER SCHEDULENo. Face Size Material Face Pattern Damper Mounting Finish Use Manufacturer
1 34" x 10" STAINLESS STEEL H LOUVERED NONE SURFACE WHITE RETURN 3/4" BLADE SPACING, 45 DEG DEFLECTON PRICE
Model
735
Description
2 12" x 8" STAINLESS STEEL H LOUVERED NONE SURFACE WHITE RETURN 3/4" BLADE SPACING, 45 DEG DEFLECTON PRICE 735
G.C. TO PROVIDE OPENING.COORDINATE SIZE WITH G.C.
CEILINGGRILLE
EXHAU
ST A
IR
FLEXIBLE INSULATEDDUCT SIZETO MATCH FAN DISCHARGE
REMOVE AND REISTALLINSULATION AROUND FAN WHERE REQUIRED
ROOF CAP - PROVIDE ROOF CAPOR EXHAUST FAN W/BDD. FLASHROOF TO MAKE WATER TIGHT .COODINATE INSTALLATION WITHROOF ING CONTRACTOR.
EXISTING ROOF DECK
PROVIDE DUAL SS STRAPS ATALL POINTS BETWEEN FLEX DUCTAND TERMINATION POINTSPROVIDE TAPE TO SECUREINSULATION.
CEILING EXHAUST FAN
M
LOUVER FRAME
SET LOUVER INFROM EXTERIORFACE OF WALL
L 1-1/2" x 1-1/2" x 1/8" GALVANIZED ANGLE, TOP & BOTTOM, CONTINUOUS ANGLE
18 Ga. GALV SLEEVE
PROVIDE CAULK SEALANT ALL AROUND
BIRD SCREEN IN REMOVABLE FRAME (WHEN SCHEDULED)
PROVIDE LOUVER PER SCHEDULE
DAMPER, MOTORIZED CONTROL,BACKDRAFT, COUNTERBALANCED
BACKDRAFT OR OTHER (WHEN SCHEDULED)
DUCTWORK (WHEN SHOWN IN PLAN)
EXTERIOR WALL
1" FLANGE ON ALUMINUM DUCT
16 GA. ALUMINUM WIRE SCREEN1/2" MESH IN REMOVABLE FRAME
20 GAUGE ALUM. SLEEVE
FILL CAULKING SLOT ALL AROUNDWITH CLEAR SILICONE
GRILLE
TAMPER RESISTANT STAINLESS SCREWS
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
4/25
/201
9 2
:44:
21
PM
C:\
Use
rs\J
Jarr
ett\
Doc
umen
ts\2
1829
11 -
New
Par
k A
men
ities
Bld
g -
MP
_jja
rret
t.rvt
M-101
MECHANICAL PLANS
JLJ
JSN
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES
BUILDING
VILLAGE OF CELORON
1/4" = 1'-0"M-101
1 MECHANICAL PLAN
NOT TO SCALEM-101
2 EXHAUST FAN DETAIL - THRU ROOF
N
NOT TO SCALEM-101
3 SURVEILLANCE EQUIPMENT ROOM LOUVER DETAILNOT TO SCALEM-101
4 RESTROOM LOUVER DETAIL
MECHANICAL KEY NOTES:
SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF BRICK VENT. MOUNT STAINLESS GRILLE ON INSIDE OF WALL WITH TAMPER RESISTANT SCREWS.
MOUNT LOUVER WHERE SHOWN ON ARCHITECTURAL DRAWING. RUN DUCT DOWN TO 12" ABOVE FLOOR. KEEP DUCT AS TIGHT TO WALL AS POSSIBLE. MOUNT GRILLE IN FACE OF DUCT.
INSULATE EXHAUST DUCT FROM FAN DISCHARGE TO UNDERSIDE OF ROOF.
SET THERMOSTAT AT 75 DEG F. WHEN SPACE TEMPERATURE EXCEEDS SETPOINT, THE EXHAUST FAN SHALL START AND RUN, AND THE MOD SHALL OPEN.
1
2
3
4
Revisions
NO: DATE: DESCRIPTION:
ELECTRICAL GENERAL NOTES
FOR EXACT LOCATIONS AND SURFACE FINISH CONDITIONS OF CEILINGS, WALLS, OR FLOORS, REFER TO ARCHITECTURAL DRAWINGS.
FOR EXACT LOCATION OF FACILITY EXPANSION JOINTS, FIRE RATED WALLS, AND SMOKE WALLS, REFER TO ARCHITECTURAL DRAWINGS.
VERIFY EXACT LOCATION OF CONNECTION POINTS PRIOR TO ROUGH-IN.
COORDINATE LOCATIONS OF ALL RECEPTACLES AND LUMINAIRES IN MECHANICAL SPACES WITH HVAC CONTRACTOR PRIOR TO ROUGH-IN TO AVOID CONFLICTS WITH EQUIPMENT AND DUCTWORK.
MOUNTING HEIGHTS ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS NOTED OTHERWISE, EXCEPT FOR PENDANT LIGHTING WHICH ARE TO THE BOTTOM OF THE LUMINAIRE. FOR AREAS WITH DIFFERENT FLOOR LEVELS, HEIGHT IS BASED UPON CLOSEST FLOOR OR LANDING TO DEVICE, EQUIPMENT, OR LUMINAIRE. ELEVATIONS GIVEN ON LEGEND SHEET ARE UNLESS NOTED OTHERWISE ON DRAWINGS.
PROVIDE RACEWAY, WIRE AND CABLE, ASSOCIATED FITTINGS AND CONNECTORS, AND COMPLETE CONNECTIONS REQUIRED FOR DESIGNATED BRANCH CIRCUITS FROM DEVICE(S) TO FINAL OVERCURRENT DEVICE AND TO LOCAL CONTROL DEVICE(S) PER SPECIFICATIONS.
MINIMUM BRANCH CIRCUIT WIRE SIZE SHALL BE #12 AWG. SIZE BRANCH CIRCUIT CONDUCTORS AS PER NEC AND AS SCHEDULED ON THIS DRAWING BASED ON ACTUAL CIRCUIT DISTANCE. INCLUDE GROUND CONDUCTOR DERATINGS.
PULL A SEPARATE NEUTRAL CONDUCTOR FOR ALL BRANCH CIRCUITS REQUIRING A NEUTRAL CONNECTION. DERATE CONDUCTORS PER NEC ACCORDINGLY. MULTIWIRE BRANCH CIRCUITS ARE NOT ACCEPTABLE.
PROVIDE GROUNDING PER NEC & TIA 607B. PROVIDE GREEN GROUND CONDUCTOR IN ALL BRANCH AND FEEDER CIRCUITS.
DO NOT INSTALL ANY NEW WORK DIRECTLY ABOVE ANY ELECTRICAL PANELS, SWITCHBOARDS, SWITCHGEAR, OR TRANSFORMERS.
CIRCUIT NUMBERS SHOWN FOR EQUIPMENT TO BE CONNECTED TO EXISTING PANELBOARD(S) IS SHOWN FOR DESIGN INTENT ONLY AND MAY NOT CORRESPOND TO ACTUAL CIRCUIT BREAKER MOUNTING POSITION IN THE PANEL. UPDATE THE RECORD DRAWINGS & PANELBOARD DIRECTORY WITH THE ACTUAL CIRCUIT NUMBERS USED TO CORRESPOND TO THE PANEL DIRECTORY.
CONFIRM ALL LABELS AND ROOM NUMBERS WITH OWNER PRIOR TO FINALIZING LABELING AND PROGRAMMING.
COORDINATE FINAL OUTLET LOCATION WITH ALL TRADES AND FURNITURE/MILLWORK PLACEMENT PRIOR TO ROUGH-IN. GENERAL CONTRACTOR SHALL PROVIDE ALL DRILLING AND GROMMETING IN FURNITURE/CASEWORK FOR CORD ACCESS IF REQUIRED.
INSTALL DATA OUTLETS 6" ADJACENT TO ASSOCIATED ELECTRICAL OUTLET.
SWITCHES SHOWN SIDE BY SIDE OR GANGED SHALL BE INSTALLED UNDER A COMMON COVERPLATE, UNLESS NOTED OTHERWISE.
PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS, CEILINGS, & ROOFS AS CALLED OUT ON ARCHITECTURAL PLANS. PROVIDE ACOUSTICAL SEALANT AT PENETRATIONS THROUGH ALL NON-FIRE RATED WALLS, FLOORS, & CEILINGS.
PROVIDE CONDUIT EXPANSION JOINTS AT ALL EXPANSION JOINTS AS CALLED OUT ON ARCHITECTURAL PLANS.
SITE PLAN CONDUIT ROUTING SHOWN FOR INTENT. REFERENCE CIVIL DRAWINGS FOR UNDERGROUND COORDINATION AND DISTANCE OF RUNS. COORDINATE WITH ALL TRADES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
ELECTRICAL LEGEND
DEVICE SUBSCRIPTS
II ROMAN NUMERAL INDICATES QUANTITY OF GANGED DEVICES UNDER COMMON FACEPLATE+xx HEIGHT OF DEVICE ABOVE FINISHED FLOOR (IN INCHES)a LOWER CASE LETTER(S) INDICATES SWITCH CONTROL ARRANGEMENT5 NUMERAL INDICATES BRANCH CIRCUIT NUMBER (POWER & LIGHTING)/CANDELA RATING (FIRE ALARM DEVICES)AC INSTALL ABOVE COUNTER, AT 40" AFF. COORDINATE WITH GCCL INSTALL FLUSH IN CEILINGCLS INSTALL ON SURFACE OF CEILINGD DIMMER SWITCH (LIGHTING CONTROL)EO EQUIPMENT SUPPLIED BY OWNEREQ INSTALL IN EQUIPMENT/CASEWORKETR EXISTING TO REMAINEWC RECEPTACLE FOR WATER COOLER. COORDINATE EXACT LOCATION WITH GC & PC PRIOR TO ROUGH-INFL INSTALL FLUSH IN FLOORGFCI GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLEGFI GROUND FAULT CIRCUIT INTERRUPTING BREAKER PROTECTEDGFP FEED THROUGH GROUND FAULT CIRCUIT INTERRUPTING PROTECTEDH INSTALL HORIZONTALLYHA HIGH ABUSE COVERPLATE WITH CENTER PIT REJECT SCREWSK KEY OPERATEDLV LOW VOLTAGENIC NOT IN CONTRACT/PROVIDE BY OTHERSO OCCUPANCY SENSOR (AUTOMATIC 'ON' LIGHTING SENSOR SWITCH)P PILOT STYLE TOGGLE SWITCH (PILOT LIGHT 'ON' WHILE DEVICE IS ON OR POWERED)S INSTALL ON SURFACET DIGITAL ELECTRONIC INTERVAL TIMER (LIGHTING SWITCH)TR TAMPER RESISTANTTS DIGITAL ELECTRONIC PROGRAMMABLE TIME SWITCH (LIGHTING SWITCH)VEND RECEPTACLE FOR VENDING MACHINE, INSTALL 44" AFFV VACANCY SENSOR (MANUAL 'ON' LIGHTING SENSOR SWITCH)WP WEATHERPROOF DEVICE / WEATHERPROOF WHILE-IN-USE EXTRA DUTY COVER & WEATHER RESISTANT RECEPTACLEWPS WEATHERPROOF SPRING LOADED COVER (WEATHERPROOF WHEN CLOSED), WEATHER RESISTANT RECEPTACLEWR WEATHER RESISTANT DEVICE/WEATHER RESISTANT RECEPTACLE
CIRCUIT NUMBER(S)11,131LNL1
BRANCH CIRCUIT CONDUCTOR SIZING
CONDUCTOR SIZE (AWG)
NOTES:
1.
2.
3.
4.
90MAXIMUM BRANCH CIRCUIT LENGTH AT 120V (FEET)
MAXIMUM BRANCH CIRCUIT LENGTH AT 277V (FEET)
140 225
205 325 520
#12 #10 #8
INCREASE ALL BRANCH CIRCUIT CONDUCTORS AS INDICATED BASED ON LENGTH OF CIRCUIT, INCLUDING EQUIPMENT GROUNDING CONDUCTOR.
TRANSITION FROM LARGER CONDUCTOR SIZE TO #12 AWG FOR FINAL TERMINATION TO OUTLET DEVICE. PROVIDE JUNCTION BOX WITHIN 10' OF OUTLET AND EXTEND #12 AWG CONDUCTORS TO OUTLET.
LENGTHS ARE FROM OVERCURRENT PROTECTIVE DEVICE, ALONG CIRCUIT ROUTING, TO CENTER OF EQUIPMENT LOAD.
SCHEDULE ASSUMES 12A LOAD, FOR LOADS HIGHER THAN 12A, INCREASE CONDUCTOR SIZE.
CIRCUIT NOTATION:
20A BRANCH CIRCUIT CONDUCTOR SIZING SCHEDULE:
EQUIPMENT CONNECTIONS
DIRECT CONNECTION FOR 120V EQUIPMENT CONNECTED TO NORMAL BRANCH
SINGLE PHASE MOTOR/PUMP CONNECTION, REFER TO EQUIPMENT CONNECTION SCHEDULE
THREE PHASE MOTOR/PUMP CONNECTION, REFER TO EQUIPMENT CONNECTION SCHEDULE
SINGLE POINT EQUIPMENT CONNECTION, REFER TO EQUIPMENT CONNECTION SCHEDULE
355
825
#6
565
1310
#4
N
PROVIDE MINIMUM WIRE SIZE AS FOLLOWED UNLESS NOTED OTHERWISE:20A CB - #12 AWG30A CB - #10 AWG40A CB - #8 AWG50A CB - #8 AWGINCREASE SIZE OF CONDUCTOR FOR DISTANCE AS SHOWN BELOW IN 20A BRANCH CIRCUIT CONDUCTOR SIZING SCHEDULE.
SOURCE PANELBOARD (IF OTHER THAN NOTED ON SHEET/CIRCUIT BOUNDARY)
GENERAL LINEWORK DESCRIPTIONS & DRAWINGS NOTES
NEW WORK
EXISTING WORK / FUTURE PROVISIONS / NOT IN CONTRACT WORK
WORK TO BE REMOVED (DEMO PLANS) - DEVICE AND ALL ASSOCIATED ELECTRICAL WORK SHALL BE REMOVED BACK TO THE SOURCE, UNLESS NOTED OTHERWISE / UNDERFLOOR/UNDERGROUND CONDUIT (NEW PLANS)
WIRE AND / OR CONDUIT RUN CONTINUED ON REFERENCED DETAIL
MATCH LINE REFERENCING CONTINUATION ON OTHER DRAWING
CALLOUT BOUNDARY - DETAIL AND / OR SECTION REFERENCE / SCOPE OF WORK
BRANCH CIRCUIT BOUNDARY
DRAWING KEYED NOTES
BRANCH CIRCUITING NOTES
DEMO NOTE / FEEDER IDENTIFICATION
KITCHEN / LAB EQUIPMENT TAG
SYMBOL WITH TAIL INDICATES WALL INSTALLATION, HEIGHT AS INDICATED
INDICATES MULTIPLE DEVICES OF DIFFERENT TYPES INSTALLED UNDER COMMON COVERPLATE AT ONE LOCATION (DEVICES SHALL BE INSTALLED UNDER A COMMON COVERPLATE)
#
#
#
#
RACEWAY, BOXES, & BUSWAY
CONDUIT TURNED UP
CONDUIT TURNED DOWN
CAPPED CONDUIT
CONDUIT STUBBED AND BUSHED INTO ACCESSIBLE CEILING CAVITY
SERVICE WEATHERHEAD
MANHOLE
HANDHOLE
POWER ASSIST PUSH PLATE BACKBOX- MOUNTED 44" AFF
POWER ASSIST PUSH PLATE BACKBOX- MULLION MOUNTED 44" AFF
DEVICE BOX WITH BLANK COVERPLATE, HEIGHT AS INDICATED
DEVICE BOX WITH BLANK COVERPLATE, INSTALLED IN CEILING
JUNCTION BOX, HEIGHT AS INDICATED
JUNCTION BOX, INSTALLED IN CEILING
PULL BOX
SYSTEMS CABINET, SURFACE OR FLUSH AS SHOWN, TOP OF TRIM 74" AFF
PB
J
J
B
B
PP1
PP
HH
MH
GROUNDING, BONDING, & LIGHTNING PROTECTION
GROUND ELECTRODE CONDUCTOR
GROUND ROD
GROUND TEST STATION
MECHANICAL CONNECTION
GROUND CONNECTION (MOLDED FUSION WELD OR IRREVERSIBLE)
EQUIPMENT ROOM GROUND TERMINAL BAR, 18" AFF
TELECOMMUNICATIONS MAIN GROUNDING BUSBAR, 18" AFF
TELECOMMUNICATIONS GROUNDING BUSBAR, 18" AFF
GROUND
AIR TERMINAL
ROOF CONDUCTOR
DOWN CONDUCTOR
THRU ROOF
G
GROUND
TMGB
TGB
DC
ELECTRICAL EQUIPMENT
DISCONNECT SWITCH, TYPE PER EQUIPMENT CONNECTION SCHEDULE, SURFACE MOUNTED 48" AFF
CIRCUIT BREAKER (ONE-LINE NOTATION)
FRACTIONAL HORSEPOWER MOTOR CONTROLLER, RECESSED 44" AFF OR ABOVE CEILING (MANUAL THERMAL SWITCH)
COMBINATION MOTOR CONTROLLER/DISCONNECT, PER EQUIPMENT CONNECTION SCHEDULE, 48" AFF
MOTOR CONTROLLER, PER EQUIPMENT CONNECTION SCHEDULE, 48" AFF
VARIABLE SPEED DRIVE/VARIABLE FREQUENCY DRIVE
TRANSFORMER (PLAN NOTATION)
TRANSFORMER (ONE-LINE NOTATION)
METER CABINET/SOCKET (ONE-LINE & PLAN NOTATION)
XXXA-3P
T
M
VFD
M
VSD
ELECTRICAL DEVICES
NEMA 5-20R DUPLEX RECEPTACLE, 18" AFF
NEMA 5-20R DUPLEX RECEPTACLE, INSTALLED FLUSH IN CEILING
NEMA 5-20R GFCI DUPLEX RECEPTACLE, 18" AFF
NEMA 5-20R QUADPLEX (DOUBLE DUPLEX) RECEPTACLE, 18" AFF
NEMA 5-20R QUADPLEX (DOUBLE DUPLEX) RECEPTACLE, INSTALLED FLUSH IN CEILING
NEMA CONFIGURATION TO MATCH INDICATED EQUIPMENT OR AS CALLED OUT, 18" AFF
+30"PI
CIRCUIT #INSTALLATION HEIGHT TO CENTER OF DEVICE IN INCHES (IF OTHER THAN SPECIFIED ON LEGEND)
SUBSCRIPT (IF APPLICABLE)
GENERAL ELECTRICAL DEVICE NOTATION:
15
1LNL1
SOURCE PANELBOARD (IF OTHER THAN NOTED ON SHEET/CIRCUIT BOUNDARY)
LIGHTING CONTROL DEVICES
SINGLE POLE TOGGLE SWITCH, 44" AFF
DIGITAL ELECTRONIC INTERVAL TIMER, WALL-BOX STYLE, 44" AFF
DIGITAL ELECTRONIC PROGRAMMABLE TIME SWITCH, WALL-BOX STYLE, 44" AFF
VACANCY SENSOR SWITCH, DUAL TECHNOLOGY [PIR / ULTRASONIC TECHNOLOGY], SINGLE POLE, WALL-BOX STYLE, 44" AFF
OCCUPANCY SENSOR, LINE VOLTAGE, DUAL TECHNOLOGY [PIR / ULTRASONIC TECHNOLOGY], WIDE VIEW, CEILING MOUNTED
DAYLIGHT SENSING DEVICE (ON/OFF CONTROL), CEILING MOUNTED
PHOTOCELL DEVICE, LINE VOLTAGE, 12" ABOVE ROOF, AIMED NORTH
T
OS
DS
P
V
TS
NOTE: LIGHTING CONTROL DEVICES SHOW FUNCTIONAL REQUIREMENTS, NOT ALL DEVICES NEEDED FOR A FULLY FUNCTIONING SYSTEM. DEPENDING ON CONFIGURATION AND MANUFACTURER, DEVICES SUCH AS POWER PACKS, RELAYS, SINGLE/DOUBLE/TRIPLE
OUTPUT ROOM CONTROLLERS MAY BE NECESSARY. REFER TO DETAILS & SPECIFICATIONS.
LIGHTING
GEOMETRIC SHAPE LUMINAIRE, RECESSED OR SURFACE MOUNTED PER LUMINAIRE SCHEDULE
ILLUMINATED EXIT SIGN - SINGLE/DOUBLE FACE AS SHOWN - DIRECTION OF ARROWS AS INDICATED - CEILING, SURFACE WALL, OR PERPENDICULAR WALL AS SHOWN
SELF CONTAINED BATTERY LIGHTING UNIT
REMOTE LIGHTING LAMP HEAD(S) - CONNECT TO REMOTE BATTERY PACK IN INTERIOR ACCESSIBLE CEILING SPACE
LUMINAIRE(S) AND POLE ASSEMBLY
SURFACE AT GRADE / FLUSH TO GRADE LUMINAIRE
FLOOD OR MONO-POINT LUMINAIRE
BOLLARD WITH INTEGRAL LUMINAIRE
a
CIRCUIT #
SWITCHLEG CONTROL ARRANGEMENT15
1LNL1SOURCE PANELBOARD(IF OTHER THAN NOTED ON SHEET/CIRCUIT BOUNDARY)
GENERAL LUMINAIRE NOTATION:
LD1
LUMINAIRE TYPE - REFER TO LUMINAIRE SCHEDULE
POLE TYPE - REFER TO SITE LIGHTING POLE SCHEDULE/LUMINAIRE SCHEDULE
P-A
DOTS INDICATE PENDANT HUNG
ARROW INDICATES AIMING DIRECTION (WHERE APPLICABLE)
TAIL INDICATES WALL MOUNT STYLE LUMINAIRE
PATTERN INDICATES LUMINAIRE CONNECTED TO UNSWITCHED LIGHTING CIRCUIT
R4 RELAY DESIGNATION (IF APPLICABLE)
NOTE: PROVIDE CONDUIT FROM BOX STUBBED INTO ACCESSIBLE CEILING SPACE. ALL OUTLET ROUGH-INS SHALL BE 4-11/16" SQUARE X 2-1/8" DEEP BACKBOX WITH 4-11/16" SQUARE X 1-1/2" DEEP EXTENSION RING OR 4-11/16" SQUARE X 3-5/8" DEEP BACKBOX. BACKBOX SHALL BE GALVANIZED SHEET STEEL WITH NOT LESS THAN (6) 1-1/4" KNOCKOUTS. PROVIDE SINGLE OR DOUBLE GANG MUDRING AND BLANK COVERPLATE AS INDICATED, OF DEPTH AND TYPE TO PROVIDE A FLUSH INSTALLATION IN FINISHED WALL OR CEILING CONSTRUCTION. PROVIDE CONDUIT FROM BOX STUBBED INTO ACCESSIBLE CEILING SPACE WITH PULLSTRING.
DATA/TELECOMMUNICATIONS OUTLET, 18" AFF
DATA/TELECOMMUNICATIONS OUTLET, 44" AFF OR 6" ABOVE COUNTER
DATA/TELECOMMUNICATION OUTLETS
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/24
/201
9 3
:09:
31
PM
C:\
Use
rs\A
Lysi
ak\D
ocum
ents
\Rev
it Lo
cal F
iles\
2182
911
- N
ew P
ark
Am
eniti
es B
ldg
- EL
EC -
R18
_m
ajor
min
otau
r5.r
vt
E-001
ELECTRICAL NOTES,
SYMBOL LEGEND, &
ABBREVIATIONS
APL
TAH
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
Revisions
NO: DATE: DESCRIPTION:
04/24/2019
EPEP
EP
EPEP
EP
EP EP
EP
EP
EP
EP
PO
PO
PO PO
PO
PO
PO
PO
JS
JS
JS
MS
RFRF
RF
RFRF
RF RF
CA CA CA
CA
CA
CA
CA
CA
CA
40' -
0"
25' - 4"
10' - 0"
214'
- 4
" +/-
METER
POLE 51060
UNDERGROUND CONDUIT - COORDINATE WITH PLUMBING CONTRACTOR TO BE AT LEAST 5' AWAY FROM WATER LINES.
REPAIR PATHWAY
POLE 50320
LIGHTING DISCONNECT SWITCH
HH
COMPLY WITH JAMESTOWN BPU UTILITY WIRING RULES, REQUIREMENTS, AND PER DETAIL DWG E2017012 - LOCATED WITHIN SPECIFICATIONS.
INTERCEPT EXISTING UNDERGROUND CABLING HANDHOLE, RECONNECT EXISTING CIRCUITS. COORDINATE WITH JAMESTOWN BOARD OF PUBLIC UTILITIES & OWNER
UNDERGROUND CONDUIT - REFER TO POWER DISTRIBUTION ONE-LINE DIAGRAM FOR SIZE & WIRING ON E-101, ROUTE TO AVOID TREE ROOTS. ELECTRICAL CONTRACTOR RESPONSIBLE FOR ALL EXCAVATION, BACKFILL, RESTORATION, & ELECTRICAL WORK IN ALTERNATE.
ALTERNATE E-1
HH
HH
PULLBOX
HH
HH
(1) 2.5" CONDUIT WITH 3 OF 300 KCMIL ALUMINUM
(1) 1" CONDUIT WITH PULLSTRING (FUTURE COMMUNICATIONS)
UNDERSLAB CONDUIT, COORDINATE WITH FOUNDATIONS
APPROX AREA - CROSS OVER SEWER LINE - COORDINATE WITH PC.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/24
/201
9 3
:09:
32
PM
C:\
Use
rs\A
Lysi
ak\D
ocum
ents
\Rev
it Lo
cal F
iles\
2182
911
- N
ew P
ark
Am
eniti
es B
ldg
- EL
EC -
R18
_m
ajor
min
otau
r5.r
vt
E-100
ELECTRICAL SITE PLAN
APL
TAH
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
1" = 20'-0"E-100
1 ELECTRICAL SITE PLAN
Revisions
NO: DATE: DESCRIPTION:
04/24/2019
T
M
J J J J J
JJJJ
PB
OS
OS
DS
MDP
+44"
+18"
+18"
+44"
+44"+18"
+44"
3MDP
3MDP
S
S
+44"
3MDP
S
11MDP
9MDP
6MDP
CONNECT TOILET SENSORS USING 2#18AWG WIRE. PROVIDE BACKBOXES FOR SENSORS PER MANUFACTURERS RECOMMENDATIONS. COORDINATE EXACT LOCATION IN FIELD WITH PLUMBING CONTRACTOR PRIOR TO ROUGH-IN. (TYP ALL)
TELCO DEMARC, PROVIDE BACKBOARD. STUB UP AND CAP CONDUIT W/ PULL STRING
ROUTE BELOW CONCRETE SLAB
REFER TO SITE PLAN
REFER TO SITE PLAN REFER TO
SITE PLAN
PROVIDE EMPTY BACKBOXES WITH 3/4" RACEWAY BACK TO TELCO DEMARC
#6 GEC
MIN 6'-0"
HD-2
HD-1
TS-1
WH-1
RP-1
EF-3
EF-1
EF-2
SURVEILLANCE EQUIPMENT03A
STORAGE03
MENS02
PLUMBING CHASE03B
WOMENS01
H-1
17MDP
15MDP
1MDP
1MDP
8,10MDP
7MDP
4MDP
5MDP
13MDP
3MDP
ALTERNATE E-1
+44"3
MDP
S S
LINE VOLTAGE THERMOSTAT (FURNISHED BY MECH CONTRACTOR)
120V DAMPER
T
V
V
LS2 LS2 LS2
LS1LS1
LS4
LS4
LS4
K
K
LS3
LS3
LS1LS1
EBU1
EBU1
EBU1
2MDP
2MDP
LD1
2MDP
LD1
MDP
1MDP
2MDP
2MDP
1MDP
1MDP
2MDP
2MDP
2MDP
1MDP
1MDP
1MDP
1MDP
STORAGE03
SURVEILLANCE EQUIPMENT03A
PLUMBING CHASE03B
MENS02
WOMENS01 T
S
+120"
1
+120"
1
2
2
3
3
1MDP
1MDP
2
240VAC 60A/3P FUSED DISCONNECT SWITCH NEMA 3R
TO JAMESTOWN BPU POLE MOUNTED
XFMR
M
TO EXISTING PARK LIGHTING
ALTERNATE E-1
120/240V MDP
100A MCB
3 #1 AWG AL IN 2" C
3 #4 AWG AL IN 1" C
3 #4 AWG AL + #8 AL GND IN 1" C
24" X 24" X 6" NEMA 4 PULLBOX
#6 AWG CU GEC
#6 AWG CU GEC
CONNECT TO ALL ELECTRODES IN BUILDING INCLUDING BUILDING STEEL AND WATER PIPE 500 East Sixth Street
Jamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/24
/201
9 3
:09:
33
PM
C:\
Use
rs\A
Lysi
ak\D
ocum
ents
\Rev
it Lo
cal F
iles\
2182
911
- N
ew P
ark
Am
eniti
es B
ldg
- EL
EC -
R18
_m
ajor
min
otau
r5.r
vt
E-101
ELECTRICAL FLOOR PLAN
APL
TAH
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORON
0 8' 12' 16'4'
GRAPHIC SCALESCALE: 1/4" = 1'-0"
E-101 - KEYED NOTES
1 COORDINATE WITH OTHER TRADES IN THIS AREA FOR EXACT LOCATION PRIOR TO ROUGH-IN TO AVOID OBSTRUCTIONS.
2 CONNECT TO CIRCUIT UNSWITCHED.
3 CONNECT TO PROGRAMMABLE TIME SWITCH IN STORAGE ROOM 03 & CONNECT TO LOAD SIDE OF DAYLIGHT SENSOR. SET SENSOR TO TURN OFF AT 30 FOOTCANDLES.
1/4" = 1'-0"E-101
1 1ST FLOOR POWER & SYSTEMS PLAN1/4" = 1'-0"E-101
2 1ST FLOOR LIGHTING PLAN
NOT TO SCALEE-101
3 POWER DISTRIBUTION ONE-LINE DIAGRAM
N N
Revisions
NO: DATE: DESCRIPTION:
04/24/2019
A A
6"MIN
12"
6"MIN
8"MIN.
18"
12"
13"
SECTION A-A
COVER DETAIL
CRUSHED STONE
SAND BED OR CONCRETE AS CALLED FOR IN DETAIL3" MIN ABOVE AND BELOW CONDUIT
3/8"-16 UNC STAINLESS STEEL HEX HEAD BOLT WITH WASHER (TYP OF 2)
1/2"X4" PULL SLOT
LOGO - POWER OR COMMUNICATIONS AS APPLICABLE
PLAN VIEW
SKID RESISTANT HEAVY DUTY COVER WITH LOGO
(2) PRECAST POLYMERCONCRETE (STACKABLE) PULL BOXES.QUAZITE #PC SERIES OR EQUAL
CONDUIT
GASKET
BOX AND COVER FLUSHWITH GRADE
GRADE
CONDUIT
LIGHTING
12"
33" MIN
12"3
6" MIN
FINAL GRADE
NOTE: USE THIS DETAIL FOR ALL SITECONDUIT UNLESS NOTED OTHERWISE
SIZE & QUANTITY OF CONDUIT AS NOTED. SCHEDULE 40 PVC CONDUIT WITH CONDUCTORS AS NOTED.
3" BETWEEN CONDUITS (IF APPLICABLE)
COMPACTED BACKFILL
SAND ENCASE CONDUIT 3" MIN ON ALL SIDES
WARNING MARKER OVER ENTIRE LENGTH
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
NYS DOS CONTRACT NO.: C1001143
NOTE: THIS DRAWING WAS PREPARED WITH FUNDING PROVIDED BY THE NEW YORK STATE DEPARTMENT OF STATE UNDER TITLE 11 OF THE ENVIRONMENTAL PROTECTION FUND.
4/24
/201
9 3
:09:
35
PM
C:\
Use
rs\A
Lysi
ak\D
ocum
ents
\Rev
it Lo
cal F
iles\
2182
911
- N
ew P
ark
Am
eniti
es B
ldg
- EL
EC -
R18
_m
ajor
min
otau
r5.r
vt
E-102
ELECTRICAL SCHEDULES
APL
TAH
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES BUILDING
VILLAGE OF CELORONESTIMATED DEMAND - NC HEAT/COOL: 56 A
NON-COINCIDENT HEATING/COOLING: 0 A
ESTIMATED DEMAND CURRENT: 56 A
CONNECTED CURRENT: 56 A
Receptacle 1980 VA 100.00% 1980 VA ESTIMATED DEMAND LOAD: 13519 VA
Lighting 506 VA 100.00% 506 VA CONNECTED LOAD: 13519 VA
Equipment 11045 VA 100.00% 11045 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD TOTALS
TOTAL CONNECTED PHASE CURRENTS: 55 A 58 A
TOTAL CONNECTED PHASE LOADS: 6544 VA 6975 VA
29 SPACE -- -- -- 0 0 -- -- -- SPACE 30
27 SPACE -- -- -- 0 0 -- -- -- SPACE 28
25 SPACE -- -- -- 0 0 -- -- -- SPACE 26
23 SPARE 20 A 1 0 0 -- -- -- SPACE 24
21 SPARE 20 A 1 0 0 -- -- -- SPACE 22
19 SPARE 20 A 1 0 0 -- -- -- SPACE 20
17 *HAND DRYER HD-2 - MENS 02 20 A 1 1690 0 -- -- -- SPACE 18
15 *HAND DRYER HD-1 - WOMENS 01 20 A 1 1690 0 1 20 A SPARE 16
13 *TOILET SENSORS TS-1 20 A 1 50 0 1 20 A SPARE 14
11 WOMENS - CONV REC 20 A 1 180 0 1 20 A SPARE 12
9 MENS - CONV REC 20 A 1 180 3000 10
7 SURVEIL RM - WALL HEATER H-1 20 A 1 1000 30002 40 A WATER HEATER WH-1
8
5 RECIRC PUMP RP-1 20 A 1 100 720 1 20 A SURVEILLANCE EQUIPMENT RECEPTACLES** 6
3 RECEPTACLES 20 A 1 900 205 1 20 A EXHAUST FAN EF-3 4
1 BATHROOMS - EF-1/EF-2/LTG 20 A 1 641.4 170 1 20 A ENTRANCE/PLUMB CHASE/STORAGE - LTG 2
CKT CIRCUIT DESCRIPTION BKR POLES A B POLES BKR CIRCUIT DESCRIPTION CKT
** PROVIDE GFCI CIRCUIT BREAKER
* PROVIDE CIRCUIT BREAKER WITH PERMANENT LOCKING PROVISIONS
PANELBOARD SCHEDULE NOTATION:
OPTIONS: ENCLOSURE TYPE: NEMA 1 MODIFICATIONS:
SERVICE ENTRANCE LABEL: YES MOUNTING: SURFACE MCB TRIP: 100 A
FED FROM: # OF WIRES: 3 BUS RATING: 100 A
# OF PHASES: 1 MAIN TYPE: MCB
LOCATION: STORAGE 03 DISTRIBUTION VOLTAGE: 120/240V SINGLE PHASE FULLY RATED AIC: 10K
DESIGNATION: MDPDESIGN BASE: SQUARE D NQ SERIES
EQUIPMENT CONNECTION SCHEDULE
DESIGNATION LOCATION DESCRIPTION LOAD VOLTAGE PHASEPOWERSOURCE
CIRCUITNUMBER
PROTECTIVEDEVICE
RATING (A)
NUMBEROF
POLESCONDUCTORS
& CONDUIT CONTROLLER TYPECONTROLLER
SIZECONTROLLERACCESSORIES DISCONNECT NOTES
EF-1 WOMENS 01 EXHAUST FAN 1.34 A 120 V 1 MDP 1 20 1 2#12 AWG + #12 AWG GND VIA OCCUPANCY SENSOR - - INTEGRAL TO UNIT -
EF-2 MENS 02 EXHAUST FAN 1.34 A 120 V 1 MDP 1 20 1 2#12 AWG + #12 AWG GND VIA OCCUPANCY SENSOR - - INTEGRAL TO UNIT -
EF-3 SURVEILLANCE EQUIPMENT 03A EXHAUST FAN 1.7 A 120 V 1 MDP 4 20 1 2#12 AWG + #12 AWG GND LINE VOLTAGE THERMOSTAT (FURNISHED BY MECHANICAL CONTRACTOR) - - INTEGRAL TO UNIT CONNECT DAMPER & EXHAUST FAN ON LOAD SIDE OF THERMOSTAT
H-1 SURVEILLANCE EQUIPMENT 03A WALL HEATER 1 KW 120 V 1 MDP 7 20 1 2#12 AWG + #12 AWG GND INTEGRAL THERMOSTAT - - INTEGRAL TO UNIT -
HD-1 WOMENS 01 HAND DRYER 1690 W 120 V 1 MDP 15 20 1 2#12 AWG + #12 AWG GND INTEGRAL SENSOR - - LOCKABLE SOURCE CIRCUIT BREAKER -
HD-2 MENS 02 HAND DRYER 1690 W 120 V 1 MDP 17 20 1 2#12 AWG + #12 AWG GND INTEGRAL SENSOR - - LOCKABLE SOURCE CIRCUIT BREAKER -
RP-1 STORAGE 03 RECIRC PUMP 100 W 120 V 1 MDP 5 20 1 2#12 AWG + #12 AWG GND AQUA STAT (FURNISHED BY PLUMBING CONTRACTOR) - - SOURCE CIRCUIT BREAKER WITHIN SIGHT -
TS-1 PLUMBING CHASE 03B TOILET SENSOR TRANSFORMER 50 VA 120 V 1 MDP 13 20 1 2#12 AWG + #12 AWG GND INTEGRAL - - LOCKABLE SOURCE CIRCUIT BREAKER -
WH-1 STORAGE 03 WATER HEATER 6000 W 240 V 1 MDP 8,10 40 2 2#8 AWG + #10 AWG GND INTEGRAL - - SOURCE CIRCUIT BREAKER WITHIN SIGHT -
LUMINAIRE SCHEDULEDESIGNATION DESCRIPTION VOLTAGE WATTAGE LIGHT SOURCE MANUFACTURER MODEL REMARKS
EBU1 EMERGENCY BATTERY UNIT LIGHT 5 W (2) 320 LUMEN LED LITHONIA ELM-UVOLT-LTP-SDRT-WPVS RECESS DEVICE BOX
LD1 WET LOCATION RECESSED LED DOWNLIGHT 120 V 11 W 1000 LUMEN, 80 CRI, 3500K LED EATON PORTFOLIO LD6B10D010-EU6B10208035-6LBM1MW-LGSKT6IP66 RECESSED
LS1 12"W x 57"L x 4"H VANDAL RESISTANT WET LOCATION SURFACE/PENDANT MOUNT LED LUMINAIRE 120 V 49 W 5000 LUMEN, 82 CRI, 3500K LED KENALL MLHA12-48-R-MW-PP-45L35K-DCC-1-DV-TL50 RECESS DEVICE BOX
LS2 VAPORPROOF UTILITY GLOBE LED LUMINAIRE, WALL MOUNT 120 V 26 W 1700 LUMEN, 82 CRI, 4000K LED RAB VXBRLED26NDG SURFACE MOUNT DEVICE BOX
LS3 5"W x 56"L x 4"H VANDAL RESISTANT WET LOCATION WALL SURFACE MOUNT LED LUMINAIRE 120 V 49 W 4700 LUMEN, 82 CRI, 3500K LED KENALL MLHA5-48-R-MW-PP-45L35K-DCC-1-DV-TL50 RECESS DEVICE BOX
LS4 9"W x 48"L x 3"H LENSED WRAP SURFACE/PENDANT MOUNT LED LUMINAIRE 120 V 45 W 4800 LUMEN, 80 CRI, 3500K LED LITHONIA SBL4-4800LM-80CRI-35K-NODIM-MVOLT RECESS DEVICE BOX
120 V
NOT TO SCALEE-102
1 HAND HOLE DETAIL
UTILITY METER
NOT TO SCALEE-102
2 DIRECT BURY CONDUIT TRENCH DETAIL
Revisions
NO: DATE: DESCRIPTION:
04/24/2019
BRANCH OFF TOP OF PIPE
PIPE TURNED UP
PIPE TURNED DOWN
BRANCH OFF BOTTOM OF PIPE
REDUCER
PIPE BREAK
BALL VALVE
BUTTERFLY VALVE
GATE VALVE
DRAWING SYMBOLS
ANGLE VALVE
CHECK VALVE
BALANCE VALVE
SHUT OFF VALVE (GATE, BALL,OR BUTTERFLY - REFER TO SPECS)
MOTOR OR SOLENOIDCONTROL VALVE (3-WAY)
STEAM TRAP
MOTOR OR SOLENOIDCONTROL VALVE
PRESSURE REDUCING VALVE
TRIPLE DUTY VALVE
RELIEF VALVE
STRAINER
UNION
PRESSURE GAUGE
PUMP
EQUIPMENT TO BE REMOVED
KEY NOTE
CO CO CLEAN OUT
SECTION CALLOUT
POINT OF CONNECTION
POINT OF DISCONNECTION
DEMOLITION KEY NOTE
DETAIL NUMBER
APPLICABLE CODES ABBREVIATIONS
%ACADJAFFAFGALTAMBAMPANSIAPPROXAVGBFPBHPBLDGBOBSMTBTUBVCAPCIPCLGCLRCOCOLCONNCONCCONTCU FTCVDCDADCVDCWDEMODHWDIADIPDWHDWVDWG(E)ENGREQESTETREWHEWTEXEXISTEXPEXT°F
PERCENTALTERNATING CURRENTADJACENTABOVE FINISHED FLOORABOVE FINISHED GRADEALTERNATEAMBIENTAMPERE (AMP,AMPS)AMERICAN NATIONAL STANDARD INSTITUTEAPPORXIAMTE (LY)AVERAGEBACKFLOW PREVENTERBRAKE HORSEPOWERBUILDINGBOTTOM OFBASEMENTBRITISH THERMAL UNITBALANCING VALVECAPACITYCAST IRON PIPECEILINGCLEARCLEANOUT or CARBON MONOXIDECOLUMNCONNECTIONCONCRETECONTINUOUSCUBIC FEETVALVE FLOW COEFFICIENTDOUBLE CHECK DETECTOR ASSEMBLYDETECTOR CHECK VALVEDOMESTIC COLD WATERDEMOLISH or DEMOLITIONDOMESTIC HOT WATERDIAMETERDUCTILE IRON PIPEDOMESTIC WATER HEATERDRAIN, WASTE, & VENTDRAWINGEXISTINGENGINEEREQUALESTIMATEDEXISTING TO REMAINELECTRIC WATER HEATERENTERING WATER TEMPERATUREEXISTINGEXISTINGEXPANSIONEXTERIORDEGREES FAHRENHEIT
FAFINFLFLAFPMFPSFTFUTGAGALGCGPMGPDGPHHDHGHORIZHPHPCHPSHRHVACHZIDININSULINTIPSINVKWKWHLBSLFLGLOCLPCLPSLRALWTMATLMAXMBHMECHMFGMINMISCMOCPMPCMPSMTGN/ANC
FREE AREAFINISHEDFLOORFULL LOAD AMPSFEET PER MINUTEFEET PER SECONDFOOT OR FEETFUTUREGAGE OR GAUGEGALLONSGENERAL CONTRACTORGALLONS PER MINUTEGALLONS PER DAYGALLONS PER HOURHEADMERCURYHORIZONTALHORSEPOWERHIGH PRESSURE CONDENSATEHIGH PRESSURE STEAMHOURHEATING, VENTILATING, AND AIR CONDITIONINGFREQUENCYDIAMTER, INSIDEINCHINSULATIONINTERIORIRON PIPE SIZEINVERTKILOWATTKILOWATT HOURPOUNDSLINEAR FEETLENGTHLOCATIONLOW PRESSURE CONDENSATELOW PRESSURE STEAMLOCKED ROTOR AMPSLEAVING WATER TEMPERATUREMATERIALMAXIMUMBTU PER HOUR (THOUSAND)MECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMAXIMUM OVERCURRENT PROTECTIONMEDIUM PRESSURE CONDENSATEMEDIUM PRESSURE STEAMMOUNTINGNOT APPLICABLENORMALLY CLOSED
NICNONPTNRSNTSOCODOS&YPCPLBGPHPRESSPSFPSIPSIGPRVRCVRRECIRCRHWRORPDARPMRPZSCHSPECSPLYSQSQ FTSQ INSTDSUCTT'STATTBDTCTDTEMPTMVTOTYPVVACVARVELVIFVOLWW/W/OWCOWHAWMWPDWTWWP
NOT IN CONTRACTNORMALLY OPENNATIONAL PIPE TREADNON-RISING STEMNOT TO SCALEON CENTERDIAMETER, OUTSIDEOUTSIDE SCREW AND YOKEPLUMBING CONTRACTORPLUMBINGPHASE (ELECTRICAL)PRESSUREPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPSI GUAGEPRESSURE REDUCING VALVERECEIVERRECIRCULATEHOT WATER RE-CIRCULATIONROUGH OPENINGREDUCED-PRESSURE DETECTOR ASSY.REVOLUTIONS PER MINUTEREDUCED-PRESSURE ZONESTEAM CAPTURE HOODSPECIFICATIONSUPPLYSQUARESQUARE FOOT (FEET)SQUARE INCH (INCHES)STANDARDSUCTIONTHERMOSTATTO BE DETERMINEDTEMPERATURE CONTROL CONTRACTORTEMPERATURE DIFFERENCETEMPERATURETHERMOSTATIC MIXING VALVETOP OFTYPICALVOLTVACUUMVARIABLEVELOCITYVERIFY IN FIELDVOLUMEWASTEWITHWITH OUTWALL CLEANOUTWATER HAMMER ARRESTERWATER METERWATER PRESSURE DROPWEIGHTWORKING WATER PRESSURE
NOTE:
SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
1
1
M-2
A
M-2
A
EQUIPMENT DESIGNATIONS
EXISTING PIPE, EQUIPMENT
NEW PIPE, EQUIPMENT
PIPE, EQUIPMENT
TO BE REMOVED
NOTE:
SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
NOTE:NOT ALL SYMBOLS, ABBREVIATIONS ANDEQUIPMENT DESIGNATIONS MAY APPLY TO THISPARTICULAR PROJECT. ANY ADDITIONS OROMISSIONS FROM THIS LEGEND SHEET DOES NOTIMPLY INCLUSION AND/ OR EXCLUSIONS OF ANYPARTICULAR ITEM FROM THIS PROJECT.
GENERAL NOTES
WATER HAMMER ARRESTER
P-TRAP
WHA
F.D. FLOOR DRAIN
R.D. ROOF DRAIN
F.S. FLOOR SINK
P TRAP
DPCO
CS
CV
DF
DWH
EJ
ET
EWC
EWS
FI
HB
KS
LAV
M
MS
NF
P
S
SA
SS
SH
SP
SRV
SWP
TK
UR
WC
WCO
WS
DWP
CO
BT
OS
DECK PLATE CLEANOUT
CUP SINK
CONTROL VALVE
DRINKING FOUNTAIN
DOMESTIC WATER HEATER
EXPANSION JOINT
EXPANSION TANK
ELECTRIC WATER COOLER
EMERGENCY EYEWASH/SHOWER
FILTER
HOSE BIBB
KITCHEN SINK
LAVATORY
METER
MOP SINK
NON-FREEZE HOSE BIB
PUMP
SINK
SHOCK ABSORBER (WATER HAMMERARRESTOR)SERVICE SINK
SHOWER
SUMP PUMP
SAFETY RELIEF VALVE
SEWAGE PUMP
WATER TANK
URINAL
WATER CLOSET
WALL CLEANOUT
WATER SOFTENER
DOMESTIC WATER PUMP
CLEANOUT
BATH TUB
OIL SEPARATOR
COMPRESSED AIR SANITARY DRAIN
DOMESTIC HOT WATER SUPPLY
INDIRECT WASTE
VACUUM
NG
VAC
NATURAL GAS
SAN
DHW
VENT
ACID VENT
ACID WASTE
ST
AV
AW
IW
STORM DRAIN
CA
DCW DOMESTIC COLD WATER
SANITARY DRAIN BELOW GRADESAN
ST STORM DRAIN BELOW GRADE
FUEL OIL SUPPLYFS
FUEL OIL RETURNFR
VDOMESTIC HOT WATER RECIRCDHR
1. BUILDING CODE OF NEW YORK STATE2. MECHANICAL CODE OF NEW YORK STATE3. FIRE CODE OF NEW YORK STATE4. PLUMBING CODE OF NEW YORK STATE5. ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE6. ACCESSIBLE AND USUABLE BUILDING AND FACILITIES-CABO/ANSI A117.17. NATIONAL ELECTRIC CODE8. NFPA 13: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
4/25
/201
9 2
:44:
21
PM
C:\
Use
rs\J
Jarr
ett\
Doc
umen
ts\2
1829
11 -
New
Par
k A
men
ities
Bld
g -
MP
_jja
rret
t.rvt
P-001
PLUMBING LEGEND SHEET
JLJ
JSN
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES
BUILDING
VILLAGE OF CELORON
PLUMBING GENERAL NOTES
1 DO NOT SHUT DOWN ANY PLUMBING, FIRE PROTECTION, NATURAL GAS, OR RELATED SYSTEMS WITHOUT BUILDING OWNER'S PRIORWRITTEN APPROVAL. FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL AS ALL REQUIREMENTS OF THISPROJECT.
2 IF REQUIRED, PROVIDE SHUT DOWNS AND TIE-INS DURING OFF HOURS TO AVOID DISRUPTION OF BUILDING SYSTEMS. COORDINATE ALLSHUT DOWN REQUIREMENTS PRIOR TO SUBMITTING BID (INCLUDE ALL REQUIRED DURING OFF HOURS IN BID).
3 PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. OBTAIN ALL REQUIRED PERMITS.
4 PROVIDE ALL REQUIRED EXCAVATION, BACKFILL AND COMPACTION FOR ALL UNDERGROUND WORK.
5 FIELD VERIFY EXACT LOCATION, DEPTH, COMPOSITION AND CONDITION OF ALL PIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OFTHE CONTRACT.
6 PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS AND DECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORKWITH OWNER AND GENERAL CONTRACTOR AND ALL TRADES.
7 PROVIDE SCHEDULE 40 BLACK STEEL PIPE SLEEVES FOR ALL UNDERGROUND PIPING PASSING THROUGH OR UNDER FOOTINGS, WALLS,FOUNDATION WALLS, SLABS FLOORS AND/OR UNDERGROUND STRUCTURES. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONALREQUIREMENTS.
8 WHERE PIPING IS LOCATED OVER FOOTINGS AND/OR OTHER UNDERGROUND STRUCTURES, ROLL DOWN AS REQUIRED TO CONNECT TOSYSTEMS NOTED. PROVIDE ALL REQUIRED OFFSETS, FITTINGS AND CONNECTIONS.
9 PITCH ALL SANITARY, WASTE, AND STORM PIPING AS FOLLOWS: PIPING SMALLER THAN 3", PITCH AT 2 PERCENT (1/4" PER FOOT) MINIMUM.3" AND LARGER, PITCH AT 1 PERCENT (1/8" PER FOOT) MINIMUM.
10 CONNECT TO SITE PIPING OUTSIDE BUILDING AS SHOWN. PROVIDE ALL REQUIRED OFFSETS, FITTINGS AND CONNECTIONS. FIELD VERIFYEXACT LOCATION, DEPTH AND COMPOSITION OF SITE SERVICES AND COORDINATE ALL WORK WITH SITE CONTRACTOR.
11 COORDINATE ALL VENT TERMINATIONS ABOVE ROOF WITH HVAC CONTRACTOR. ALL VENT TERMINATIONS ABOVE ROOF SHALL BE AMINIMUM 10'-0" AWAY FROM ANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC.).
12 PROVIDE SINGLE HOSE BIBB WITH VACUUM BREAKER (HB) UNDER LAVATORY(S) IN ALL TOILET ROOMS WITH FLOOR DRAINS. ONE REQUIREDPER ROOM.
13 REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECT SPECIFICATIONS FOR ANY PROJECT PHASING REQUIREMENTS.
14 THE ENTIRE PLUMBING SYSTEM SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE PLUMBING CODE OF NEW YORK STATE ANDLOCAL PLUMBING INSPECTOR.
15 THE EXISTING PIPING INDICATED ON THESE PLANS SHALL BE VERIFIED IN THE FIELD FOR EXACT LOCATIONS, QUANTITY, AND PIPE SIZES.
16 THE PIPING INDICATED ON THESE PLANS ARE DIAGRAMATIC. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES PRIOR TOINSTALLATION. CONTRACTOR SHALL COORDINATE ROUTING OF ALL PIPING WITH EXISTING CONDITIONS AND SHALL PROVIDE ANYNECESSARY OFFSETS, REROUTING, TEES, ELBOWS, ETC. REQUIRED FOR A COMPLETE AND COORDINATED INSTALLATION.
17 THE CONTRACTOR SHALL OBTAIN AND PAY ALL FEES RELATED TO PERMITTING, INSPECTIONS, TAP-ON FEES, ETC, INCLUDING THE CITY OFJAMESTOWN AND SOUTH AND CENTER SEWER DISTRICT.
18 CONTRACTOR SHALL COORDINATE ANY PLUMBING OR PIPING SYSTEM SHUTDOWN WITH THE OWNER 5 DAYS IN ADVANCE.
19 CONTRACTOR SHALL COORDINATE AND PROVIDE ALL NECESSARY PIPING & PLUMBING FITTINGS, PIPING, MISCELLANEOUS ITEMSREQUIRED FOR A COMPLETE INSTALLATION OF ALL PLUMBING RELATED ITEMS.
20 ALL WORK SHALL BE COORDINATED WITH THE EQUIPMENT VENDORS.
21 THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL UNDER SLAB PIPING WITH EXISTING STRUCTURAL FOUNDATIONS. UNDERGROUND UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO ANY WORK BEING PERFORMED. CONTRACTOR SHALL REPAIR OR
REPLACE ALL PIPING NOT IN PROPER WORKING ORDER OR DAMAGED DURING INSTALLATION OF THE NEW UNDERSLAB PIPING.
22 ALL PLUMBING & PIPING SYSTEMS SHALL BE SUPPORTED AS REQUIRED BY THE STATE AND LOCAL CODE REQUIREMENTS AND PERMANUFACTURER'S RECOMMENDATIONS.
23 ALL PIPING PENETRATIONS THROUGH NEW, EXISTING WALL, OR FLOOR SHALL BE SEALED TO EQUAL THE RATING OF THE NEW, EXISTINGWALL OR FLOOR.
24 THE PLUMBING SYSTEM SHALL BE TESTED AS REQUIRED BY STATE AND LOCAL CODE OR BY THE REQUIREMENTS OF THE LOCAL PLUMBINGINSPECTOR.
25 THE ENTIRE DOMESTIC WATER SYSTEM (EXISTING/NEW) SHALL BE DISINFECTED IN ACCORDANCE TO THE LOCAL CODE & HEALTHDEPARTMENT REQUIREMENTS.
26 THE BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED PER STATE AND LOCAL CODE & PER AUTHORITY HAVING JURISDICTIONREQUIREMENTS.
27 ALL (VTR'S) VENT THRU ROOF PENETRATIONS INDICATED ON PLANS ARE PRELIMINARY. FINAL LOCATIONS SHALL BE COORDINATED WITH ALL TRADES. ALL VTR'S SHALL BE A MINIMUM OF 10'-0" FROM ALL FRESH AIR INTAKE OPENINGS.
28 CONTRACTOR SHALL INSULATE ALL PLUMBING PIPING PER SPECIFICATION.
29 ALL WORK SHALL BE PERFORMED BY A CITY OF JAMESTOWN LICENSED PLUMBER.
Revisions
NO: DATE: DESCRIPTION:
BOULEVARD AVENUE
LINDSEY PLACE
NEW AMENITIESBUILDING
~
~
~
1315
1314
1314
1314
1314
1314
1314
1314
1313
1313
1313
1314
1314
1312
1312
1312
1313
1313
1313
1313
1312
1312
1312
1311
1311
1312
1312
1311
1311
1311
1312
1312
1313
1313
1312
1312
1312
13141314
~
~ ~
~
~ ~
~
~
~
~
~
1
2
CP#1
CP#2
CP#3
LT
LT
LT
LT
UP
UP
UPL
PRF
PRF
PR
F
PRF
PRF
PRF
PRF
PRF
HYD
APPROX. LOCATION OF 8"WATER (E)
6"W
ATE
R (
E)
6"WATER (E)
APPROX.R.O.W.
APPROX. R.O.W.
HEDGE
HEDGE
GP
GP
GP
GPGP
SIGN
SIGN
SIGN
SIGN
SIGN
SIGN
SIGN
SIGN
BLEACHERSDUGOUT
CO
NC
.C
RO
SS
WA
LK
CR
OS
SW
ALK
(WIDTH VARIES)
FLAGPOLES
CONC.MONUMENT
ASPHALT
GARDEN
CONC.
GUTTER
WHITELINE
CURB
CO
NC
.
ASPHALT
GRASS
EXIS
T. A
SPHA
LT
CONC.
STATUE
PLAYGROUND
SHELTER
GRILL
ASPHALT
ASPHALT
GARDENW
/SIGN
PITCHER'SMOUND
BASE
BASE
BASE
BASEBALLDIAMOND
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS GRASS3"
8"
20"
28"
18"
24"
28"
18"
18"
18"
18"18"
24"
30"
ROAD CENTERLINE
CURB
CURB
EXIST. ROAD CENTERLINE
ASPHALT PAVING
CONC. PADCRUSHED STONE DRAINAGE BED
PLANTING BED
ASPHALT PAVING
CONC. PAD
YCO
YCO
4" SAN @ 1.5% SLOPE
4" SAN @ 1.5% SLOPE
2" DCW
2" DCW
2" DCW
2" DCW UP
4" SAN INV 1309.93SEE P-101
CO
CURB STOP
FF 1312.5
INV 1306.10
INV 1305.50
INV 1309.55
CO
1
1
7
5
4
3
INV 1307.67
2
6
ELECTRICAL CONDUITS (SEE ELECTRICAL DRAWINGS)
ELECTRICAL CONDUITS (SEE ELECTRICAL DRAWINGS)
ELECTRICAL CONDUITS (SEE ELECTRICAL DRAWINGS)
8
8
8
8
8
FCO
VALVE BOX SHALL BE CENTERED ON VALVE AND SET
ON COMPACTED BACKFILL. IN NO CASE SHALL THE
VALVE BOX BE SUPPORTED BY THE VALVE BODY.
FOR SUPPORT. (MIN. BLOCK SIZE, 4" x 8" x 16")
CONCRETE BLOCK CENTERED UNDER VALVE
5' M
IN.
#1 CRUSHED STONE
FOR WIDTH OF TRENCH
AROUND VALVE BOX
VALVE
VALVE BOX
GRADE
NOTE:
FLOW
TYPICAL PIPINGCONNECTION FORALL FLOORCLEANOUTSPLUG AT END OF
MAIN ONLY
HEAVY DUTY CAST IRON FRAMEW/ SCORIATED, HINGED COVER(J.R. SMITH NO. 4915 OR EQUAL)
PAVING
18"x18" CONCRETE CLEANOUT BOX,SLOPE TOP FOR WATER RUNOFF.
CAST IRON CLEANOUT BODYW/ TAPERED BRONZE PLUG(J.R. SMITH NO. 4283 OR EQUAL)
. 12"
.6"
.10" EFFECTIVE
OPENING
A-A
VIEW A-A
14"
17.75"
14"
FLOW
TYPICAL PIPINGCONNECTION FORALL FLOORCLEANOUTS
CAST IRON CLEANOUT BODYW/ TAPERED BRONZE PLUG
(J.R. SMITH NO. 4283 OR EQUAL)
17.75"
12.75"
15"
TURF WRAPPED COVER AND BOX -LEVEL WITH GRADE
GRADE
8x16x4" THICK CONCRETE SUPPORT BLOCK (TYP 4)
PROVIDE 1/4" STAINLESS STEEL BOLT (TYP 2). DRILL AND TAP COVER TO SECURE.
PROVIDE 1/4" STAINLESS STEEL
BOLT (TYP 4). DRILL AND TAP MOUNTING
FLANGE. BOLT COVER TO FLANGE.
SELECT BACKFILL
END VIEW
TOP VIEW
IN AREAS WITH WET ORUNSTABLE BOTTOMS USE1 1/2" STONE, DEPTH AS
DIRECTED BY THE ENGINEER.
MINIMUM COVER
MACHINE BACKFILL
IN 6" LIFTS
24" FOR SAN. WASTE PIPE
12"
12"
HAND BACKFILL WITH SELECTEDLOOSE EARTH, SAND ORGRAVEL AND COMPACT.
UNDERGROUND PIPE
MACHINE BACKFILL WITH GOOD FILLAS DIRECTED, EXCLUDING LARGEROCKS, FROZEN CHUNKS, DEBRIS,
OR SPONGY MATERIAL ANDCOMPACT AS SHOWN WITHOPTIMUM MOISTURE CONTENT.
HAND BACKFILL WITH SELECTED
MATERIALS AND COMPACT
90% COMPACTION
95% COMPACTION
GRADE
DETECTABLE WARNING
TAPE
FOR SURFACE RESTORATIONREFER TO ADDITIONAL DETAIL3/P-G001
NOTE:BEDDING AND BACKFILLMATERIALINSTALLED & COMPACTED INMAXIMUM 6" LIFTS.
PIPE BEDDING MATERIAL:
• NYSDOT 703-020150-50 MIXTURE OFPRIMARY SIZE 1 &2
• IN ROCK, BACKFILLPIPE ZONE WITHSAND
PIP
E Z
ON
E
12"
PIP
EO
.D.
WARNINGTAPE
TRENCH BACKFILL MATERIAL:
• ROADWAY, SIDEWALK AND ALLDRIVEWAY AREAS:SHALL BE SELECT GRANULAR FILL.
• NON PAVED AREAS:SHALL BE COMMON EARTH BACKFILL
A A
SAFE OPERATIONSHEET PILING
(AS REQUIRED)
6" MIN.IN ROCK
6" MIN.IN ROCK
PIPE
O.D.
DIM. APIPE DIA.
UP TO 18"
19" TO 36"
OVER 36"
1'-0" (MIN.)
1'-6" (MIN.)
2'-0" (MIN.)
6"
9"
12"
DIM. B
B
AT EXISTING PAVEMENT:INITIAL SAWCUT TYPICALEACH SIDE OF TRENCH.(SEE PAVEMENT JOINT DETAILFOR PAVEMENT RESTORATION)
EXISTING ORPROPOSED SURFACE
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
4/25
/201
9 2
:44:
22
PM
C:\
Use
rs\J
Jarr
ett\
Doc
umen
ts\2
1829
11 -
New
Par
k A
men
ities
Bld
g -
MP
_jja
rret
t.rvt
P-002
SITE PLUMBING PLAN
JLJ
JSN
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES
BUILDING
VILLAGE OF CELORON
N
1" = 20'-0"P-002
1 PLUMBING SITE PLAN
NOT TO SCALEP-002
5 MAINLINE VALVE DETAIL
NOT TO SCALEP-002
3 EXTERIOR CLEANOUT DETAIL
KEY NOTES:
PROVIDE PLAYING FIELD ACCESS COVER. SEE DETAIL.
PROVIDE 1" THICK x 24" WIDE EXTRUDED FOAM INSULATION OVER THE TOP OF ALL SANITARY PIPING WITH LESS THAN 48" OF SOIL COVER, INCLUDING UNDER PAVEMENT TO BUILDING FLOOR PENETRATION.
CONNECT TO EXISTING 6" WATER LINE IN STREET PER JAMESTOWN BPU REQUIREMENTS. CONNECT TO LINE PRIOR TO HYDRANT CUTOFF VALVE. APPLY FOR PERMIT AND PAY ALL FEES. CUT AND PATCH STREET PER MUNICIPAL AUTHORITY REQUIREMENTS. PROVIDE ALL SAFETY EQUIPMENT AND PERSONNEL DURING CONSTRUCTION.
PROVIDE CURB STOP ASSEMBLY PER JAMESTOWN BPU REQUIREMENTS.
PROVIDE NEW UNDERGROUND WATER LINE TO BUILDING. MAINTAIN 5'-0" MINIMUM COVER. EXCAVATE AND RESTORE ALL SURFACES TO MATCH EXISTING. PROVIDE TRENCH AND BACKFILL FOR WATER LINE.
CONNECT TO MANHOLE PER SOUTH AND CENTER SEWER DISTRICT REQUIREMENTS. APPLY FOR PERMIT AND PAY ALL FEES. CUT AND PATCH STREET PER MUNICIPAL AUTHORITY REQUIREMENTS. PROVIDE ALL SAFETY EQUIPMENT AND PERSONNEL DURING CONSTRUCTION.
PROVIDE SCHEDULE 40 PVC PIPE SLEEVE FOR DOMESTIC WATER PIPE TO 5 FEET FROM CENTER LINE OF SEWER PIPE IN BOTH DIRECTIONS. PROVIDE 18" SEPERATION FROM SLEEVE TO SEWER LINE. OFFSET WATER LINE DOWN THRU SLEEVE AND BACK UP AS REQUIRED.
COORDINATE WORK WITH ELECTRICAL CONDUIT. MAINTAIN 5'-0" MINIMUM SEPERATION.
1
2
3
4
5
6
7
NOT TO SCALEP-002
6 FIELD CLEANOUT ACCESS BOX
8
NOT TO SCALEP-002
4 SANTARY PIPE BEDDING DETAIL
NOT TO SCALEP-002
2 WATER PIPE BEDDING DETAIL
Revisions
NO: DATE: DESCRIPTION:
2" DCW DOWN
WH-1
WC-2
WC-2
WC-1
WC-1 WC-1
UR-2 UR-1 UR-1
LAV-2
LAV-2LAV-1
LAV-1
DF-1
2" DCW2" DCW
1" DHW
1/2" DHR
2" DCW
1 1/2" DCW
1 1/2" DCW1" DCW
3/4" DCW
3/4" DHW
1/2" DCW
HB-1
1" DCW
1
HB-1
2
2
5
1
3 3 3
44
4
44
WC-1
4
1 1
HB-1
26
HB-1
2
3/4" DCW
2" D
CW
UG
2" DCW (UG)
RP-1
RPZ-1
SEE SITE PLAN FOR CONTINUATION
WOMENS01
MENS02
STORAGE03
SURVEILLANCEEQUIPMENT
03A
WH-1
WC-2
WC-2
WC-1
WC-1WC-1
UR-2 UR-1 UR-1
LAV-2
LAV-2
LAV-1
LAV-1
FD-1
FD-1
FD-14" SAN DOWN
4" SAN
4" SAN
4" SAN
4" SAN
2" V3" V
3" V3" V2" V2" V
2" V
4" DRAIN TO OUTSIDE WITH BUG SCREEN
CO
CO4" SAN 4" SAN 4" SAN 4" SAN
4"
SA
N
4" SAN 4" SAN
4" SAN
2" V4" SAN
4"
SA
N11
7
3
3
3
WC-1 4
444
4
2
41 1
FD-1
72
5
6
7
4" SAN
DF-1
SEE SITE PLANFOR CONTINUATION
4" SAN FCO
WOMENS01
MENS02
SURVEILLANCEEQUIPMENT
03A
STORAGE03
FCOFCO
WC-2
WC-1
WC-2
WC-1
WC-1
WC-1
UR-1
UR-1
UR-2
FD-1
FD-1
FD-1
FD-1
WH-1
LAV-2
LAV-1
LAV-2
LAV-1
DF-1
RPZ-1
WATER METER
AIR BLOW OUT PORT
2" DCW UG
2" DCW
3/4" DCW
1" DCW
1" DHW
1/2" DHR
1" DCW
2" DCW
1" DCW
1" DHW
1/2" DHR
2" DCW
1" DCW
1" DCW
3/4" DCW
3/4" DCW3/4" DCW
1" DCW
1" DCW
1 1/2" DCW
1 1/2" DCW
1" DCW
1/2" DCW
3/4" DCW
1/2" DCW
1/2" DCW
3/4" DCW
3/4" DCW
1/2" DCW
1/2" DHW
1/2" DHR
1/2" DCW
1/2" DHW
1/2" DHR
1/2" DHW
1/2" DHR
3/4" DHW
1/2" DHW
1/2" DHR
3/4" DHW
HB-1
HB-1
HB-1
HB-1
SEE WATER HEATER DETAIL
FCO
DRAIN VALVE RP-1
FCO
FCO
4" SAN UG
4" SAN UG
4" SAN UG
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN4" SAN UG
WC-2
WC-1
WC-2
WC-1
WC-1
WC-1
UR-1
UR-1UR-2
FD-1
FD-1
FD-1
FD-1
WH-1
LAV-2
LAV-1
LAV-2
LAV-1
DF-1
3" VTR
3" V
2" V
2" V
2" V
2" V
2" V
3" V
2" V
2" V
3" V
2" V
2" V
2" V
2" V
2" V1 1/2" V
1 1/2" V
1 1/2" V
1 1/2" V
2" V
4" SAN
4" SAN UG
1 1/2" SAN
FLOOR
3" V
FCO
FCO
FCO
4"(E) UG
4"(E) UG
CO
CO
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
4/25
/201
9 2
:44:
24
PM
C:\
Use
rs\J
Jarr
ett\
Doc
umen
ts\2
1829
11 -
New
Par
k A
men
ities
Bld
g -
MP
_jja
rret
t.rvt
P-101
PLUMBING PLAN
JLJ
JSN
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES
BUILDING
VILLAGE OF CELORON 1/4" = 1'-0"P-101
1 DOMESTIC PLUMBING PLAN 1/4" = 1'-0"P-101
2 SANITARY PLUMBING PLAN
N N
PLUMBING KEY NOTES:
PROVIDE LAV AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1/2" DCW, DHW, DHR DOWN TO FIXTURE. PROVIDE 2" SAN UP TO FIXTURE. PROVIDE 1-1/2" VENT UP.
PROVIDE HB AND ALL ASSOCIATED ACCESSORIES. PROVIDE 3/4" DCW DOWN TO FIXTURE.
PROVIDE UR AND ALL ASSOCIATED ACCESSORIES. PROVIDE 3/4" DCW DOWN TO FIXTURE. PROVIDE 2" SAN UP TO FIXTURE. PROVIDE 2" VENT UP.
PROVIDE WC AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1" DCW DOWN TO FIXTURE. PROVIDE 4" SAN UP TO FIXTURE. PROVIDE 2" VENT UP.
PROVIDE DF AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1/2" DCW DOWN TO FIXTURE. PROVIDE 2" SAN UP TO FIXTURE. PROVIDE 1-1/2" VENT UP.
PROVIDE WH-1 AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1" DCW, 1" DHW, 1/2" DHR DOWN. SEE P-501 FOR CONNECTION DETAILS. ROUTE DRAIN PIPING FROM WH RELIEF TO FD.
PROVIDE FD AND ALL ASSOCIATED ACCESSORIES. PROVIDE 4" SAN UP TO FIXTURE WITH P-TRAP.
1
2
3
4
5
6
P-101
3 DOMESTIC ISOMETRICP-101
4 SANITARY ISOMETRIC
7
PLUMBING GENERAL NOTES:
1. PITCH ALL PIPING TO SERVICEABLE LOW POINTS TO PERMIT COMPLETE DRAINAGE FOR COLDER WEATHER.
Revisions
NO: DATE: DESCRIPTION:
ELEVATION
CHASE
VENT PIPE
URINAL
FLUSH VALVE
REFER TOARCHITECTURALELEVATIONS FORMOUNTING HEIGHT
CARRIER. REFER TOSPECIFICATION SECTION15410.
-
C.I. CLEANOUTFERRULE & PLUG
SANITARY/STORMSEWER
CLEANOUT ACCESS COVER (DPCO) PROVIDE 18"X18"X6" CONCRETE PAD
WHEN FINISHING AT EXTERIOR OFBUILDING. FINISHED FLOOR OR PAVEDAREA.
FD-1 (NICKEL BRONZE GRATE) REFER TO PLUMBING ACCESSORIES SPECIFICATIONS.
FINISH FLOOR OR TILE
MEMBRANE FLASHING AS REQUIRED.
MEMBRANE ANCHOR FLANGE
ADJUSTABLE COLLAR WITH 1-5/8" TO 2-3/4" ADJUSTMENT TO
FINISH FLOOR
ASSE 1072 MECHANICAL TRAP SEAL FITTING
4" DEEP SEAL P-TRAP
24"
MIN
ALL THREAD ROD
NUT (TOP & BOTTOM)
WASHER (TOP & BOTTOM)
CLEVIS HANGER
INSULATION
PIPE
INSULATION PROTECTIVESHEETMETAL SHIELD
METAL DECK CONCRETE FLOOR SLAB
WATERPROOF CAULK
PIPE INSULATION (WHERE REQ'D)
PIPE
6"
FIRE RESISTANT SILICONE FOAM SEALER
PIPE SLEEVE
CUT OPENING IN EXISTING
PRESSURE INJECT EPOXY GROUT TOCOMPLETELY FILL ANNULAR SPACE
BETWEEN PIPE AND WALL . SEESPECIFICATION 030130 MAINTENANCE OF
CONCRETE.
CUT OPENING IN EXISTING
PRESSURE INJECT EPOXY GROUT TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE AND WALL . SEE SPECIFICATION 030130 MAINTENANCE OF CONCRETE.
CONTINUOUSLY WELDED WATER STOP & ANCHOR COLLAR, WATERPROOF FLOORS ONLY. MIN. 1" ALL OTHERS TO HAVE ANCHOR LUGS (MIN. 3 REQ'D).
MIN.12"
10"
18"
SEALANT
STAINLESS STEELCLAMP
FLASHING
VENT
ROOFING
ROOF DECK
ELEVATION
1'-0"
CHASE
VENT
WALL
CARRIERBODY
PIPE SUPPORT
FLUSH VALVE
ESCUTCHEON
SEAT
WATER CLOSET
ADJUSTABLE FEET
PIPE FITTING
FINISHED FLOOR
C.W. SUPPLY
FINISHED FLOOR
PRESSURE GAUGE
METER
RPZ-1
60" MAX30" MIN
2" DOMESTIC COLD WATER SERVICE
BACKFLOW PREVENTER AIR GAPDISCHARGE FITTING, PIPED
FULL SIZE TO EXTERIOR (TYP.)PROVIDE SCREEN ON DISCHARGE
2" DOMESTIC COLD WATERTO FACILITY
ADJUSTABLE PIPESUPPORT (TYP.)
WATER METER BYUTILITY COMPANY
SHUT-OFF VALVE (TYP.)
2" REDUCED PRESSUREZONE BACKFLOW
PREVENTER
4"
2"
2"
PRV
8" MINIMUM BEHIND BFP FOR SERVICE30" IN FRONT FOR SERVICE
DRAIN VALVE WITH HOSE CONNECTION AND VACUUM BREAKER
A. 1.28 GPF, DUAL-FILTERED FIXED BYPASS DIAPHRAGM, ROUGH BRASS FINISH, POLISHED CHROME WALL PLATE FINISH, SINGLE FLUSH, 2-10.75 L DIMENSION, HARDWIRED, SENSOR-OPERATED, SLOAN® CONCEALED SENSOR FLUSHOMETER. EXTRA HEAVY WEIGHT INJECTION MOLDED SOLID PLASTIC ELONGATED SEAT WITH OPEN FRONT, LESS COVER AND STAINLESS STEEL SELF SUSTAINING CHECK HINGES, SIMILAR TO BEMIS 1655SSC.
B. 0.5 GPF, DUAL-FILTERED FIXED BYPASS DIAPHRAGM, ROUGH BRASS FINISH, POLISHED CHROME WALL PLATE FINISH, SINGLE FLUSH, LESS CONTROL STOP, 2-10.75 L DIMENSION, HARDWIRED, SENSOR-OPERATED, SLOAN® CONCEALED SENSOR URINAL FLUSHOMETER. CARRIER WITH DURA COATED RECTANGULAR STEEL UPRIGHTS ANCHORS TO FLOOR WITH BEARING PLATE, SIMILAR TO ZURN MODEL Z1222.
C. DECK MOUNTED CHROME PLATED CAST BRASS, 4" FIXED CENTERS, 4" RIGID SPOUT WITH 1.5 GPM VANDAL RESISTANT AERATOR, ADA COMPLIANT METERING PUSH BUTTON INDEXED HANDLES, SIMILAR TO T&S MODEL B-0831-VF05. CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1/4" TAILPIECE, SIMILAR TO McGUIRE MODEL 155A. CHROME PLATED CAST BRASS 1-1/4"x1-1/2" P-TRAP WITH CLEAN OUT PLUG AND TUBING TO WALL WITH SET-SCREW ESCUTCHEON SIMILAR TO MCGUIRE MODEL 8902. CHROME PLATED CAST BRASS SUPPLIES WITH LOOSE KEY ANGLE STOP AND SET-SCREW ESCUTCHEON. PROVIDE TRAP AND SUPPLY COVERING TO MEET ADA REQUIREMENTS, SIMILAR TO "PRO-WRAP".
D. CAST IRON DEEP SEAL P-TRAP, SIMILAR TO ZURN MODEL Z-1000 AND MECHANICAL SEAL SIMILAR TO SURE SEAL.
SHUT OFF WATER SUPPLY TO FACILITY AND OPEN ALL DRAIN VALVES.
WINTERIZING PROCEDURE
1.1 WATER SUPPLY
AFTER REMOVAL OF ALL FLUSH VALVES, AND DISCONNECTION OF WATER SUPPLIES, PURGEPIPING SYSTEM WITH COMPRESSED AIR.
LEAVE HEAT OPERATIONAL IN METER ROOM.
REMOVE FLUSH VALVE COMPLETE WITH DIAPHRAGM, ACTUATOR, VACUUM BREAKER, ETC.AND PLACE IN PLASTIC (ZIPLOC) BAG AND STORE IN A COOLER DARK AREA ABOVE FREEZING.
1.4 WATER CLOSETS
REMOVE WATER FROM WATER CLOSET TRAP AND FILL WITH ANTI-FREEZE.
1.5 URINALS
REMOVE FLUSH VALVE COMPLETE WITH DIAPHRAGM, ACTUATOR, VACUUM BREAKER, ETC.AND PLACE IN PLASTIC (ZIPLOC) BAG AND STORE IN A COOLER DARK AREA ABOVE FREEZING.
REMOVE WATER FROM URINAL TRAP AND FILL WITH ANTI-FREEZE.
1.6 LAVATORIES
DISCONNECT SUPPLIES AND APPLY COMPRESSED AIR TO THE SUPPLY SERVING THE FAUCETTO REMOVE STATIC WATER IN THE FAUCET.
REMOVE WATER FROM LAVATORY TRAP AND FILL WITH ANTI-FREEZE.
DISCONNECT ELECTRICAL POWER.
1.7 WATER HEATER
REMOVE THE CLEANOUT PLATES OR DRAIN VALVE FROM THE BOTTOM OF THE WATERHEATER. LEAVE BASE PLATES OR VALVE OFF WHILE HEATER IS NOT IN USE.
ALL TRAPS MUST BE FILLED WITH PLUMBER'S ANTI-FREEZE TO PREVENT SEWER GASESFROM FILLING UP THE FACILITY DURING PERIOD IT IS NOT USED. TRAPS INCLUDE INTERNALFIXTURE TRAPS (I.E. WATER CLOSETS) AND EXTERNAL P-TRAPS (I.E. FLOOR DRAINS).
1.8 ANTI-FREEZE
OPEN HOSE BIB AND PURGE PIPING WITH AIR.
1.9 HOSE BIB
PLUMBING FIXTURE SCHEDULEMark Trim Cold Hot San/W Vent Support Remarks Manufacturer Model
WC-1 A 1" --- 4" 2" CARRIER --- AMERICAN STANDARD 2634.101
WC-2 A 1" --- 4" 2" CARRIER ADA AMERICAN STANDARD 2634.101
UR-1 B 3/4" --- 2" 2" CARRIER --- AMERICAN STANDARD 6515.001
UR-2 B 3/4" --- 2" 2" CARRIER ADA AMERICAN STANDARD 6515.001
LAV-1 C 1/2' 1/2' 1-1/2' 1-1/2' CARRIER --- AMERICAN STANDARD 0355.012
LAV-2 C 1/2' 1/2' 1-1/2' 1-1/2' CARRIER ADA AMERICAN STANDARD 0355.012
FD-1 D --- --- 4" 2" FLOOR MTD. --- WATTS FD-100-A
HB-1 --- 3/4" --- --- --- WALL MTD. --- JR SMITH 5509QT
ELECTRIC WATER HEATER SCHEDULEMark Service Location Storage Cap. Elements Watts/Element Total Watts Recovery @ 110°F Accessories Electric Dimensions Remarks Manufacturer Model
WH-1 TOILET ROOMS STORAGE 30 1 6000 6000 25 GPH T&P RELIEF 240/1 20" DIA. x 36" H --- LOCHINVAR CHA06030A
DF-1 --- 1/2" --- 1-1/2" 1-1/2" WALL MTD. --- ELKAY LK4409BF
REMOVE FRONT PANEL TO DISCONNECT COOLER FROM ELECTRICAL SUPPLY AND SHUT OFF WATER. NOTE: COOLERS WITH AN ELECTRICALLY OPERATED SOLENOID VALVE WILL NEED TO HAVE THE ELECTRICITY ON TO ALLOW THE SOLENOID VALVE TO BE OPENED.DISCONNECT 3/8" WATER LINE FROM SHUTOFF VALVE.DEPRESS THE PUSH-BUTTON AND BLOW COMPRESSED AIR INTO THE 3/8" WATER INLET LINE THROUGH ENTIRE COOLER WATER SYSTEM UNTIL ONLY AIR COMES OUT OF THE BUBBLER.REMOVE THE TRAP FROM THE DRAIN LINE AND EMPTY ANY WATER.
1.10 DRINKING FOUNTAIN
RECIRCULATION PUMP SCHEDULETAG SERVICE LOCATION GPM@FT. HD. PIPE CONNECTION SIZE
MOTORMANUFACTURER & MODEL OPTIONS & ACCESSORIES NOTES
HP RPM VOLT/PH/HZ
RP-1 RESTROOM LAVATORIES STORAGE 1.0 @ 9.5' 1/2" NPT 1/40 3250 115/1/60 TACO 006B 7 DAY TIMER & AQUASTAT 1,2
BACKFLOW PREVENTER SCHEDULENo. Location Service Type Shut-off Valves Conn. Size Design Flow Press. Drop Notes Manufacturer Model
RPZ-1 SURVEILLANCE EQUIPMENT DOMESTIC WATER REDUCED PRESSURE ZONE 1/4 TURN FULL PORT BALL VALVES 2" 65 GPM 13 PSI 1,2,3 Watts LF 909-QT
NOTES:1. LEAD FREE CONSTRUCTION.2. PROVIDE AIR GAP FITTING.3. PROVIDE INLINE STRAINER.
NOTES:
1. PROVIDE AQUASTAT AND 7 DAY TIMER. WIRE TO CONTROL PUMP.2. UNION CONNECTIONS.
NOTES:1. PROVIDE AMTROL ST-12 EXPANSION TANK
DISCONNECT ELECTRICAL POWER. REMOVE PUMP FROM PIPING AND DRAIN ALL WATER. REINSTALL PUMP.
1.11 RECIRCULATION PUMP
D
FUNNEL WASTE CONN.,PIPED AS INDICATED ONPLANS
FINISHED FLOOR
DRAIN PAN WITH OUTLETPIPED TO W CONN W/ AIR GAP
SHUT-OFF VALVE (TYPICAL)
VACUUM RELIEF VALVE
DIELECTRIC UNION(TYPICAL)
TEMPERATURE ANDPRESSURE RELIEF VALVE
THERMOMETER W/ WELL (TYPICAL)
RELIEF PIPE - FULL SIZE TOWASTE W/ INDIRECT CONN.
COLD WATER SUPPLY
HOT WATER SUPPLY
RECIRCULATING HOT WATER
DIAPHRAGM EXPANSION TANK
HOT WATER RECIRC. PUMP (RP-1),CONTROLLED BY TIME CLOCKSUPPLIED WITH PUMP.
CHECK VALVE (TYPICAL)
BALANCING VALVE(TYPICAL)
ELECTRIC WATER HEATER
HOUSEKEEPING PAD
DRAIN VALVE
MAY EXTEND ASWASTE OR VENT
FOR WALL CONSTRUCTIONREFERENCE ARCH. DWGS.
C.I. CLEANOUT TEE
WASTE LINELENGTH TO SUIT
CLEANOUT PLUG
COUNTERSUNKSCREW
POUSHED S.S.ACCESS COVER
1/8" BEND ANDEND OF LINECLEANOUT
WASTE LINE
LEAN CONCRETE OR CLSM
2" WATER PIPE
FINISHED GRADE
FOUNDATIONAND FOOTING
TO WATER METER
COMPACTEDEARTH
COMPACTED EARTH
SLAB ON GRADE FLOOR.
NOTES:1. PROVIDE THRUST BLOCKS AT ALL BELOW GRADE CHANGES IN
DIRECTION. SEE DETAILS 3/C6.2 AND 4/C6.22. PROVIDE SLEEVES AT ALL WALL AND FLOOR PENETRATIONS.3. PROVIDE HANGERS AND SUPPORTS FOR ALL PIPING PER CODE.4. PROVIDE 1" THICK FIBERGLASS INSULATION WITH ASJ AND VAPOR
BARRIER ON ALL INTERIOR COLD WATER PIPING.5. PROVIDE 2" FOAM BOARD INSULATION FROM FROST LINE TO FLOOR
SLAB ON ALL BELOW GRADE EXTERIOR WALLS PRIOR TO BACK FILLING
2" FOAM INSULATIONBOARD. EXTEND TO
FROST LINE.
SEE SLEEVE DETAIL
SEE SLEEVE DETAIL
SEE TRENCH AND PIPEBEDDING DETAIL
6" MIN
5' MINIMUM
ALL JOINTS BRAZED
PRESSURE GUAGE
1/2" THERMOSTATIC
TEMPERING VALVE (TYP)
1/2" TW
1/2" CW SUPPLY
1 1/4" O.D. TAILPIECE
1/2" CW SUPPLY1/2" HW SUPPLY
1/2" TW
1/2" CW SUPPLY1/2" CW SUPPLY1/2" HW SUPPLY
1 1/4" O.D. TAILPIECE
NOTE: HOT WATER RECIRCULATION PIPING SHALL CONNECT TODOMESTIC HOT WATER LINE WITHIN 2'-0" OF FIXTURE CONNECTION. SEE PLANS FOR PIPE SIZING.
DHR
DHW
DCW
OMEGA THERMAL BALANCEVALVE, 0.5 GPM MAX.
1/2" FOR UP TO 2 LAVS3/4" FOR UP TO 7 LAVS
3/8" OR 1/2" HW CONNECTION
FLOOR
WALL
V
1-1/4"
CONNECT VENT SYSTEMABOVE CEILING
1 1/2"
1/2"
CONNECT 1/2" CW TOMAIN ABOVE CEILING
1/2"
3/8" THICK PLATE, STEEL, PAINTED
3/8" STAINLESS BOLTS (TYP 4)DF-1
TRAP
VALVE
UNION
WATER
OPERATING ROD AND CASINGLENGTH = WALL DEPTH + 2"
WALL BOX
GRADE
WALL
THICKNESS
MIN
24"
SHUTOFF VALVE
UNION 3/4" HOSECONNECTION
3/4" I.P.S.
3/4" CW OPTIONAL WATER
FEED FROM ABOVEBUILDING EXTERIOR
BUILDING INTERIOR
ACCESS PANELLOCATION BASEDON PIPE FEED
3/4" CW OPTIONAL WATERFEED FROM ABOVE
WALL BOX
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
4/25
/201
9 2
:44:
25
PM
C:\
Use
rs\J
Jarr
ett\
Doc
umen
ts\2
1829
11 -
New
Par
k A
men
ities
Bld
g -
MP
_jja
rret
t.rvt
P-501
PLUMBING DETAILS
JLJ
JSN
APRIL 26, 2019
BID / CONSTRUCTION
2182911
21 Boulevard Ave, Celoron 14720
NEW PARK AMENITIES
BUILDING
VILLAGE OF CELORON
NOT TO SCALEP-501
12 WALL HUNG URINAL DETAIL
NOT TO SCALEP-501
2 DECKPLATE CLEANOUTNOT TO SCALEP-501
3 FLOOR DRAIN DETAILNOT TO SCALEP-501
4 PIPE CLEVIS HANGER DETAIL NOT TO SCALEP-501
5 PIPE SLEEVE THROUGH FLOOR DETAIL
NOT TO SCALEP-501
6 VENT THROUGH ROOF
NOT TO SCALEP-501
9 WALL HUNG WATER CLOSET DETAIL
NOT TO SCALEP-501
13 WATER SERVICE DETAIL
NOT TO SCALEP-501
1 ELECTRIC WATER HEATER DETAIL
NOT TO SCALEP-501
14 WALL CLEANOUT
NOT TO SCALEP-501
8 WATER SERVICE LEAD-IN DETAIL
NOT TO SCALEP-501
11 DUAL LAVATORY DETAIL
NOT TO SCALEP-501
7 DRINKING FOUNTAIN DETAIL
NOT TO SCALEP-501
10 HOSE BIB DETAIL
Revisions
NO: DATE: DESCRIPTION: