Vinyl Acetate CH3CO2CH:CH2 No.143 10 20 40 60 80 100 ppm n=2 143 1 ppm4 pump strokesWhite Brown Temperature 0 to 40 (32 to 104 ) correction not used Relative humidity 0 to 90 % correction not used 15 % for 10 to 20 ppm, 10 % for 20 to 100 ppm10 tubes for 5 tests 36 months Detecting limit : Colour change : Operating conditions : Relative standard deviation : Tube quantity and number of tests per box : Shelf life : Performance 5 to 10 ppm 10 to 100 ppm 100 to 250 ppm 4400 mL2200 mL1100 mL1/2 1 2.5 2 min 1 min 30 sec Measuring range Number of pump strokes Correction factor Sampling time CH3CO2CH:CH2 C6H3 CH33 H2S2O7 Condensation polymer Reaction principle Diffusion tube method Calibration gas generation When used, these tubes are to be connected. See page 2-3. Possible coexisting substances and their interferences Aldehydes, Ketones Brown Etylene 1000 ppm Yellow Vinyl chloride 500 ppm Substance Concentration Interference Changes colour by itself to Scale

Vinyl Acetate CH CO CH:CH No

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Vinyl Acetate CH CO CH:CH No

Vinyl Acetate CH3CO2CH:CH2 No.143

10 20 40 60 80 100

ppm

n=2

143

1 ppm(4 pump strokes)White → BrownTemperature 0 to 40 ℃ (32 to 104 ℉) correction not usedRelative humidity 0 to 90 % correction not used15 %(for 10 to 20 ppm), 10 %(for 20 to 100 ppm)10 tubes for 5 tests36 months

Detecting limit :Colour change :Operating conditions :

Relative standard deviation :Tube quantity and number of tests per box :Shelf life :

Performance

5 to 10 ppm 10 to 100 ppm 100 to 250 ppm 4(400 mL) 2(200 mL) 1(100 mL) 1/2 1 2.5 2 min 1 min 30 sec

Measuring rangeNumber of pump strokesCorrection factorSampling time

CH3CO2CH:CH2 + C6H3(CH3)3 + H2S2O7 → Condensation polymer Reaction principle

Diffusion tube methodCalibration gas generation

When used, these tubes are to be connected. See page 2-3.

Possible coexisting substances and their interferences

Aldehydes, Ketones + BrownEtylene ≧ 1000 ppm + YellowVinyl chloride ≧ 500 ppm +

Substance Concentration Interference Changes colour by itself to

Scale