3-Door Interlock A w/ Push Button & Key Switch OverrideSolution #10 - Three Door Interlock A
+(-)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SW1
SW2
(-) NO
NCC
(-) NO
NCC
(-) NO
NCC
(-) NO
NCC
W
D
W
DFUSE
W
D
W
DFUSE
W
D
W
DFUSE
W
D
W
DFUSE
(-) NO
NCC
(-) NO
NCC
(-) NO
NCC
(-) NO
NCC
Power Input12/24 VDC
OUTPUT 1 OUTPUT 3
C A1 C A2 C B1 C B2 C C1 C C2 C E1 C E2
OUTPUT 7
Station A Station B Station C Station D Auxiliary Inputs
OUTPUT 5OUTPUT 4OUTPUT 2 OUTPUT 6 OUTPUT 8
C E3 C E4C D1 C D2
DOOR #1
DOOR#2
DOOR#3
631RFA
BatteryChargerIndicator Fuse
AC PowerLED
PrimaryFuse 250V1.5Amp
BatteryInput
12V
SHORT
OPEN
24V
VOLTAGE SELECT
System StatusLED
Note:Set to 24VDC.
Power must be turned off before changing voltage jumper
G W B
TO 120VAC PRIMARYVOLTAGE CONNECTION
(Remove factory installed jumper only when fire alarm interface is used)
+-
DC Voltage Output
Terminals+ - C
FIRE ALARM INTERFACE –
CLOSED CONTACT
435UR – Door #1
(N/O)(N/O)
(N/C)(N/C)
DPST (Maintained)
435UR – Door #2
(N/O)(N/O)
(N/C)(N/C)
DPST (Maintained)
DPS
{CLOSEDCOMOPEN
BAS
{
1511VD
DPS
{CLOSEDCOMOPEN
BAS
{
1511VD
DPS
{CLOSEDCOMOPEN
BAS
{
1511VD
435UR – Door #3
(N/O)(N/O)
(N/C)(N/C)
DPST (Maintained)
POWER POWER POWER
Set JumpersJ1,J3 & J5 To “W”
Set Dip Switch SW-2-8 ONAll other switches OFF
System Components:(1) 631RFAXUR4-8 – 1.5 Amp Regulated Power Supply w/ Fire AlarmInterface & 4-Station Universal Controller(3) 1511VD – 1650lb Grade 1 EMLock® w/ integral Door Position Switch(3) 435UR – Red 1.5" Mushroom Button, Alternate-action, DPST (NO/NC)(1) 701U – 6A Key Switch, Single-gang, Alternate-action, SPDT(1) CYL-KDQ – 1-1/8" Key cylinder with 2 keys, for 700 Series Key Switch
Method of Operation:All doors are normally closed and unlocked.
Interlock Operation: Opening any door will cause the other doors to lock until the opened door returns to its normal state.
Push Button Override:Pressing the mushroom button located at each door will immediately unlock its respective door. The door will remain unlocked until the button is pressed a second time, returning the door to normal operation.
Interlock Bypass:Turning the key switch cylinder will activate a maintained switch, turning off the interlock system. Any door may be opened at any time. Activating the switch a second time will return the interlock system to normal operation.
Fire & Life Safety:A signal from the Fire Alarm Panel will immediately unlock all doors.
-- -- -- ------ Page 1 of 1
-PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:--801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.