Chart IndustriesHistory• World’s largest cryogenic design/manufacture of cryogenic
equipment for over 40 years.Facilities• Worldwide facilities including North America, Czech Republic,
China, GermanyProducts• Storage tanks, pipe, transport/delivery tanks, injectors, test
chambers, controls systems, etcMarkets• Industrial gas, medical, biological, electronics, aerospace,
automotive, restaurant, beverage, etc.Vacuum Insulated Pipe Brand Names• MVE• CVI• Python
www.chart-ind.com
Types of Cryogenic Piping
Static vacuum• Section vacuums are factory sealed• Very high and stable efficiency• Long life expectancy• Simple field installation
Dynamic vacuum• Requires continuous operation of vacuum pump• Less efficient than static vacuum pipe
Foam insulated copper• Medium/low efficiency, degrades with time• Lower initial cost but higher operating cost and shorter life
www.chart-ind.com
VIP Applications
Volume related applications• Nitrogen expands 700X from liquid to gas
Refrigeration related applications• LN2 temperature is –320 degrees Fahrenheit• LN2 heat of vaporization is 92 BTU/#
www.chart-ind.com
VIP Applications
Volume related applications• N2 Purge gas
– Beverage & food packaging• Aerospace• LNG as fuel
www.chart-ind.com
VIP Applications
Refrigeration related applications• Cryo-bio storage• Biological freezing• Food freezing• Electronics testing – HALT/HASS• Entertainment – fog effects• Super conductors• Deflashing of rubber parts• Cryo tempering
www.chart-ind.com
VIP Design and construction
Sizes• Rigid
–½” pipe size thru 10” pipe size• Flex
–¼” ID flex thru 10” ID flex
www.chart-ind.com
VIP Design and construction
Pressure rating• Normally 150 psig for LN2
–Most LN2 applications require pressures of 20-70 psig
• Normally 300 psig for LCO2
• Special pressures on request
www.chart-ind.com
VIP Design and construction
Code• ASME B31.3 Process piping
New Prague manufacturing shop approvals• ASME “U” stamp
–Certificate #8,377• ISO-9001:2000 Quality System
–Certificate #GQC-246
www.chart-ind.com
VIP Design and construction
Double wall – vacuum insulated• Nearly 400 deg F temperature differential from
inner to outer• Vacuum minimizes gas conduction and
convection• Long thin walls minimize metal conduction• Multi layer super-insulation minimizes radiation
www.chart-ind.com
VIP Design and construction
Inner pipe Outer – jacket pipe End closure
Support Internal bellows Gas trap Super-insulation
www.chart-ind.com
VIP Design and construction
Materials• Inner carrier pipe options
– Pipe, welded, schedule 5, type 304 SS– Pipe, welded, schedule 5, Invar– Convoluted flex, type 321 SS– Specials on request
• Vacuum jacket material options– Pipe, welded, schedule 5, type 304 SS– Convoluted flex, type 321 SS– Specials on request
www.chart-ind.com
VIP Design and construction
Materials• Super-insulation
–Multiple layers of cryogenic grade spacer paper and aluminum foil or double aluminized Mylar
www.chart-ind.com
VIP Design and construction
Low conductivity spacers• Multiple leg support of low conductivity
composite materialsLow conductivity end connections• Bayonets are most common• Field joint end transitions
–Require welding together on-site
www.chart-ind.com
VIP Design and constructionWhen filled with LN2, SS inner pipe shrinks in relation to outer (jacket) pipe.• 0.003 inch per inch of length (0.72” / 20’).
Bellows placed on inner line or outer jacket to compensate.• Internal bellows
– Easier for on site installation– Protected from damage
• External bellows– Allows higher pressures– Cleaner flow path
Invar inner pipe has extremely low shrink rate• Bellows not required on lines shorter than 20’
www.chart-ind.com
VIP Design and constructionVacuum• All vacuum surfaces cleaned to remove contaminates• Getters installed to maintain vacuum
– Molecular sieve– Palladium oxide
• Helium mass spectrometer leak testing• Heating during evacuation process• Vacuum retention test prior to shipment
www.chart-ind.com
VIP Design and constructionEvacuation port• Annular space overpressure relief
www.chart-ind.com
VIP Design and constructionOptional Testing/Quality Measures• Radiographic inspection (5% of butt welds)• Pressure test (each section)• Inspection by ASME Authorized Inspector• Dye penetrant testing• Material traceability
www.chart-ind.com
VIP Design considerationsCryogenic liquid• LN2 – most applications• LO2 – requires special components & cleaning• LHE – requires special components & mfg• LCO2 – requires higher pressure & special
components
www.chart-ind.com
VIP Design considerations
Design Pressure – Maximum Allowable Working Pressure (MAWP)• What is the pressure required by the end use application
– What is requirement right at point of use?• What is the pressure drop through the pipe system?• What is the pressure supply capability of the liquid
source?• What is the pressure control capability of the liquid
source?• Are there multiple use points/pressure requirements
within the system?
www.chart-ind.com
VIP Design considerations
Flow requirements are used to size the pipe’s header and drop diameter sizes:• What is the end-use application’s flow requirements?• Do the flow requirements change over time?
– Change with pressure?• How many use points are in the system?• Will there be additional equipment added to the pipe
system in the future?– Consider this flow in the sizing of the main header
www.chart-ind.com
VIP - LN2 flow vs pipe size
Length equivalent is length of pipe plus fitting factorsValve = 40 feet / Elbow or tee = 20 feet / 1 foot flex = 3 feetOne foot vertical rise = 0.35 psi pressure drop for nitrogen serviceBased on 5 psi pressure drop
140 GPM48 GPM25 GPM8 GPM1 GPM500’160 GPM54 GPM28 GPM10 GPM2 GPM400’185 GPM63 GPM32 GPM11 GPM2 GPM300’
225 GPM78 GPM40 GPM14 GPM3 GPM200’325 GPM110 GPM56 GPM20 GPM4 GPM100’
3” PS2” PS1-1/2” PS1” PS½” PSLen Eq
www.chart-ind.com
VIP Design considerationsRouting• Define carefully because changes are difficult, time consuming
and costly– Useful to make the initial design, then re-visit the site with
the drawing to confirm the design will work• Be careful of obstructions (vents, electrical, pipes, etc.)
– Be sure to ask about any obstructions that may not be present at the time of design, but may be installed before the VIP is installed
• Minimize fittings to control cost (elbows, tees, bayonets, etc.)and improve system flow performance
• Flex can be used to make installation easier, or work around an obstruction such as a support beam, etc.
– Especially useful at connection points to the tank and/or end use equipment
www.chart-ind.com
VIP Design considerationsSection lengths• Longer sections generally reduce total system cost and
heat leak• 20 foot sections are optimal for manufacturing and
shipping• Consider installation issues
– Moving into building, lifting, walls, etc.• Consider shipping• May consider section breaks in places to accommodate a
future addition in specific places• There are some minimum dimensions for various fittings
based on manufacturing requirements
www.chart-ind.com
VIP Design considerationsSection connections• Bayonets
–Shrink fit design - “MVE”–Close tolerance design - “CVI”–Field joints
www.chart-ind.com
VIP Design considerations
O-ring
Female bayonet (sectioned)Clamp
Shrink fit nose Male bayonet
www.chart-ind.com
VIP Design considerations
www.chart-ind.com
VIP Design considerations
Vacuum jacketed valves
Y-PatternT-Pattern
www.chart-ind.com
VIP Design considerations
Non-jacketed cryogenic valves• Although they are not vacuum
insulated, they still need to have an extended stem so that the resulting ice ball does not grow to the valve packing
– When valve packing gets too cold, it could leak nitrogen to the environment
www.chart-ind.com
VIP Design considerations
Gas traps• Used in intermittent use drops to
control heat leak and frost.• Allows use of non-VJ valves. • Not recommended for high flow
applications due to its pressure drop• Not recommended for continuous
use applications
www.chart-ind.com
VIP Design considerationsEnd connections• Bayonets
– Most efficient– Easy to install
• Pipe threads– Will result in ice ball– Readily available connections to various equipment
• ANSI flanges– Will result in ice ball– Need to use low temperature gasket material
• Pipe stub ends– Will result in ice ball– Requires welding on-site at installation
www.chart-ind.com
VIP Design considerations
Relief valves & risers• Relief valves are required in any spot where liquid can be trapped
(between any two valves)– Consider protection at the inlet and outlet of the pipe system
• Does the supply/use equipment have protection?• Confirm pressure rating of relief valve needed
www.chart-ind.com
VIP Design considerations
Future expansion• Less expensive to add “futures” than to modify
or replace system later• Consider future expansion when sizing pipe• Typically accommodated by placing a caped
bayonet at location where expansion may take place.
www.chart-ind.com
VIP System Measurement
Location of tank and use pointsArchitectural structure of buildingLocate clearest path from tank to use pointsEstablish elevationsDesign system with maximum length sections minimizing elbows & teesEstablish flow rates to support pipe sizingEstablish use pattern
www.chart-ind.com
VIP System Measurement
Establish saturation pressure requirement at use pointCombine design, sizing and flow to establish pressure dropRecommend tank operating pressureMeasure and document the pipe routingEstablish installation procedures and material / equipment list
www.chart-ind.com
VIP System Installation
Off loading the truck• Watch for damage
–Notify driver and document any damage immediately before driver leaves!
• Consider checking section vacuums
www.chart-ind.com
VIP System Installation
Reading the print and assembling the puzzle• Isometric drawing – not to scale• Section numbers on print match section
numbers on labels–VS-1, VS-2, VS-3, etc
www.chart-ind.com
VIP System Installation
Supports / hangers• Support every 10 feet• J-hangers or cushioned pipe clamps
– Uni-strut (www.tyco-unistrut.com)– Flex-strut (www.flexstrut.com)
• External bellows pipe needs to be able to move along its axis
www.chart-ind.com
VIP System Installation
Installation equipment & supplies• Halocarbon grease to lubricate bayonet o-rings• Standard hand tools (wrenches, small hammer)• Consider need for manlift, forklift, crane• Field joints require welding and evacuation
equipment
www.chart-ind.com
VIP System Installation
Installation labor• Generally need at least two people to install any
system–Systems with longer sections, bigger
diameters, many sections, welding, etc will require more people on-site
• System with bayonets require less time and skill• System with field joints require welding and
evacuation
www.chart-ind.com
VIP System Installation
Proper bayonet assembly• Clean and inspect bayonets• Lubricate and install o-ring• Engage bayonets (do not twist)• Install V-retainer and tighten nut• Bayonets should slide together easily
– If it is difficult, it is likely due to not having the pipe sections aligned properly
– Do NOT force them together
www.chart-ind.com
VIP System Installation
Proper slope• If the system contains a Cryovent to keep the
pipe filled with liquid, the pipe must rise continuously towards the Cryovent.–Any gas bubbles must rise to the Cryovent–Any high spots will trap gas–Rise ~1” per 50’
www.chart-ind.com
VIP System Installation
Pressure / leak test• Do not exceed MAWP of pipe• If testing at more than 90% of MAWP,
temporarily replace relief valves• Use clean, dry gas, preferably nitrogen• Leak test all joints or do pressure decay test
www.chart-ind.com
VIP System Installation
Start up• Preferably isolate Cryovents• Fill slowly to minimize pressure spike• Open use point valves until there is a continuous
stream of liquid• It will be several hours before system is stable• Once system is stable, open cryovents
www.chart-ind.com
VIP System Installation
Maintenance• Monthly visual inspection of piping
–Look for sweating, frost and leaks–Check relief valves (installed & set point)
• If there are questions or issues, call Chart–Provide PN and VS number from label
www.chart-ind.com
VIP System Installation
Maintenance• Before disconnecting any bayonet or
component, verify that all pressure has been released for the system.
www.chart-ind.com
VIP Accessories
Cryovent• Keeps the VIP system filled with LN2 during periods of
no useage– Provides quick response when the system needs
liquid• Float driven valve• Installed on tee, at highest point, near use point• Pipe must rise continuously towards Cryovent
– Gas bubbles must get to the Cryovent
www.chart-ind.com
VIP Cryovent
www.chart-ind.com
VIP AccessoriesAPPS-160 Phase separator• Allows using a single storage
tank to supply a high pressure GN2 application and a low pressure LN2 application
– Lowers pressure of LN2– Sits next to supply tank– Outlet Feeds VIP system with
a vacuum insulated bayonet connection
– Operates up to 50 psig– 15 GPM max
www.chart-ind.com
Python Pipe
Python Pipe Product• Good alternative to foam insulated copper pipe• 1” & 2” pipe size in stock, 3” special order• Straight, rigid lengths from 2’ to 20’ (even feet)• Flex sections with 6’ of flex• Pre-insulated cover kits in straight, elbow & tee
configurations
www.chart-ind.com
Python Pipe
Higher heat leak means higher cost of operationEnd use system is much more efficient for customer, providing higher quality liquid and reducing losses
Foam insulation should be stripped off and re-applied to keep its efficiency
Extremely low maintenance
Plastic outer jacket and foam is easily damagedStainless steel outer jacket for durability and aesthetics
Over time will condense moisture on outer jacket and ultimately may grow mold
Will not condense moisture on outer jacket
Foam insulated pipe requires significantly larger OD for the insulation, requiring more space and higher cost of installation (wall penetrations and supports)
Smaller outer jacket means less space required for the installation and less cost for wall penetrations and pipe supports
As moisture leaks past the plastic cover, it soaks into the foam making it even less efficient. Eventually need to replace the foam!
Stainless steel outer jacket is not affected by moisture from ambient
Poor-moderate thermal performanceExcellent thermal performance (at least 5 times better than foam)
Foam Insulated PipePYTHON
www.chart-ind.com
Standard Python Joints
T-joint
Elbow joint
Straight joint
www.chart-ind.com
Python pipe
Design• Inner & outer – stainless steel pipe, schedule 5• Static vacuum – factory evacuated and sealed• Field welded, pipe stub end joints
–All weld joints are insulated in the field• 400 psig MAWP
–External bellows design
www.chart-ind.com
Python pipe
System design considerations• Even foot increments• Minimize joints to maximize efficiency• Over-all length will shorten 3-1/2” per 100’ when
filled with LN2
–Consider this when providing installation• Wall/roof penetrations• Connections to equipment
www.chart-ind.com
Python pipe
Installation• Hang sections• Weld joints (manual TIG on schedule 5 SS pipe)• Leak test joints• Install joint covers